Block diagram Overview Although digital sensors have many advantages, not all physical magnitudes can be measured with this sensors. For this restriction, Zolertia launches the family of analog sensors that are fully compatible with both Z1 and Z1SP devices. The first analog sensor created by Zolertia is ANLG001 and includes a CO- D4 sensor (Carbon Monoxide). This is a very small sensor with a long-term stability and reliable operation, well beyond the two-years. ANLG001 has a sensitivity of 880µV/ppm (40µA/ppm) and includes control and signal conditioning circuitry ready for use with the Z1 platform. In spite of being an analog sensor, ANLG001 consumption is very low because only the control, measurement converter and amplifier circuits consume energy. Typically, the entire board consumption is 6µA and the maximum is 12µA. Others gains are allowed changing the resistor R6 that functions as Rload in the Designing a potentiostatic circuit application note from Alphasense. To download this application note see the documentations links above. CO-D4 is plugged to the board with PCB sockets. For this reason, it is possible change the sensor without risk of damage.

Upload: others

Post on 27-Dec-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Overview Block diagram - SourceForgezolertia.sourceforge.net/wiki/images/3/3d/Brochure_ANLG001.pdf · Overview Block diagram Although digital sensors have many advantages, not all

Block diagramOverviewAlthough digital sensors have manyadvantages, not all physical magnitudescan be measured with this sensors. Forthis restriction, Zolertia launches thefamily of analog sensors that are fullycompatible with both Z1 and Z1SPdevices.The first analog sensor created byZolertia is ANLG001 and includes a CO-D4 sensor (Carbon Monoxide). This is avery small sensor with a long-termstability and reliable operation, wellbeyond the two-years.ANLG001 has a sensitivity of880µV/ppm (40µA/ppm) and includescontrol and signal conditioning circuitryready for use with the Z1 platform.In spite of being an analog sensor,ANLG001 consumption is very lowbecause only the control, measurementconverter and amplifier circuitsconsume energy. Typically, the entireboard consumption is 6µA and themaximum is 12µA.Others gains are allowed changing the

resistor R6 that functions as Rload inthe Designing a potentiostatic circuitapplication note from Alphasense. Todownload this application note see thedocumentations links above.CO-D4 is plugged to the board with PCBsockets. For this reason, it is possiblechange the sensor without risk ofdamage.

Anlg001CO sensor

Page 2: Overview Block diagram - SourceForgezolertia.sourceforge.net/wiki/images/3/3d/Brochure_ANLG001.pdf · Overview Block diagram Although digital sensors have many advantages, not all

Technical dataGetting startedTo start using the Anlg001, just plug thesensor into a Z1(SP) in the 3-pinPhidget Port with the included cableyou will find in the package.The easiest way to use this analogsensor is trying one of the examples inthe Zolertia wiki for both Contiki andTinyOS.As an analog sensor with measureconverter current/voltage, the obtainedreading will be a voltage measurement.This voltage depends of the value ofppm detected by the CO-D4 with asensibility of 880µV/ppm.As a result of their chemical structure,technical characteristics of the sensormay be affected by storage conditions.It is encouraged to read the specificdocuments to take into account thesepossible differences and warrantyissues.

Mechanical overviewMechanical overview

Documentation

Zolertia™Av. Parc Tecnologic, 3, PTV

08907, Cerdanyola del Val les(SPAIN)

+34 93 582 02 [email protected]

Zig lets by Zolertia™is l icensed underBSD License

CO-D4 Alphasense datasheetANLG001 code examplesZolertia wiki

Supply voltage 1.8V to 3.6V

Temperature range -20 to 50 °CPressure range 80 to 120 kPa

Board dimensions 36.7x24.3x16.9mm

Supply current 12µA, max.Sensibility 880µV/ppm

40µA/ppm

Designing a potentiostatic circuitAlphasense Applications notes