owner’s manual - wittus manual.pdf · 2019-05-10 · owner’s manual installation and operation...

48
Heat & Glo Soho24 2077-900 Rev. F 8/05 1 Owner’s Manual Installation and Operation Model: Soho24 Do not store or use gasoline or other flamma- ble vapors and liquids in the vicinity of this or any other appliance. What to do if you smell gas - Do not try to light any appliance - Do not touch any electrical switch. Do not use any phone in your building. - Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. - If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency, or the gas supplier. WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing proper- ty damage, personal injury, or death. This appliance has been supplied with an integral barrier to prevent direct contact with the fixed glass panel. Do NOT operate the appliance with the barrier removed. Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one. HOT! DO NOT TOUCH. SEVERE BURNS MAY RESULT. CLOTHING IGNITION MAY RESULT. WARNING Keep children away. CAREFULLY SUPERVISE children in same room as appliance. Alert children and adults to hazards of high temperatures. Do NOT operate with protective barriers open or removed. Keep clothing, furniture, draperies and other combustibles away. Glass and other surfaces are hot during operation and cool down. DO NOT DISCARD THIS MANUAL CAUTION Important operating and maintenance instruc- tions included. This appliance may be installed as an OEM installation in manufactured home (USA only) or mobile home and must be installed in accordance with the manufacturer’s instruc- tions and the manufactured home construction and safety standard, Title 24 CFR, Part 3280 or Standard for Installa- tion in Mobile Homes, CAN/CSA Z240MH. This appliance is only for use with the type(s) of gas indi- cated on the rating plate. Installation and service of this appliance should be performed by qualified personnel. Hearth & Home Technologies suggests NFI certified or factory-trained professionals, or technicians supervised by an NFI certified professional. DO NO DO NO DO NO DO NO DO NO T T T DISCARD DISCARD DISCARD DISCARD DISCARD In the Commonwealth of Massachusetts: installation must be performed by a licensed plumber or gas fitter; a CO detector shall be installed in the room where the appliance is installed. Read, understand and follow these instructions for safe installation and operation. Leave this manual with party responsible for use and operation.

Upload: others

Post on 12-Jun-2020

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/05 1

Owner’s ManualInstallation and Operation

Model:Soho24

• Do not store or use gasoline or other flamma-ble vapors and liquids in the vicinity of this orany other appliance.

• What to do if you smell gas- Do not try to light any appliance- Do not touch any electrical switch. Do not

use any phone in your building.- Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’sinstructions.

- If you cannot reach your gas supplier, callthe fire department.

• Installation and service must be performed bya qualified installer, service agency, or the gassupplier.

WARNING: If the information in theseinstructions is not followed exactly, a fireor explosion may result causing proper-ty damage, personal injury, or death.

This appliance has been supplied with an integral barrierto prevent direct contact with the fixed glass panel. DoNOT operate the appliance with the barrier removed.

Contact your dealer or Hearth & Home Technologies if thebarrier is not present or help is needed to properly install one.

HOT! DO NOT TOUCH.SEVERE BURNS MAY RESULT.CLOTHING IGNITION MAY RESULT.

WARNING

• Keep children away.

• CAREFULLY SUPERVISE children in same room asappliance.

• Alert children and adults to hazards of hightemperatures.

• Do NOT operate with protective barriers open orremoved.

• Keep clothing, furniture, draperies and othercombustibles away.

Glass and other surfaces are hot duringoperation and cool down.

DO NOT DISCARD THIS MANUAL

CAUTION

Important operating andmaintenance instruc-tions included.

This appliance may be installed as an OEM installation inmanufactured home (USA only) or mobile home and mustbe installed in accordance with the manufacturer’s instruc-tions and the manufactured home construction and safetystandard, Title 24 CFR, Part 3280 or Standard for Installa-tion in Mobile Homes, CAN/CSA Z240MH.This appliance is only for use with the type(s) of gas indi-cated on the rating plate.

Installation and service of this appliance should beperformed by qualified personnel. Hearth & HomeTechnologies suggests NFI certified or factory-trainedprofessionals, or technicians supervisedby an NFI certified professional.

• • •

DO NO

DO NO

DO NO

DO NO

DO NOTTTTTDISCARD

DISCARD

DISCARD

DISCARD

DISCARD

In the Commonwealth of Massachusetts:• installation must be performed by a licensed plumber

or gas fitter;• a CO detector shall be installed in the room where the

appliance is installed.

Read, understand and followthese instructions for safeinstallation and operation.

Leave this manual withparty responsible foruse and operation.

Page 2: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/052

Congratulations

Listing Label Information/Location

Model Name: ___________________________________________ Date purchased/installed: _________________

Serial Number: _________________________________________ Location on appliance: ____________________

Dealership purchased from: _______________________________ Dealer Phone: __________________________

Notes: _______________________________________________________________________________________

____________________________________________________________________________________________

Congratulations on selecting a Heat & Glo gas appliance—an elegant and clean alternative to wood burningappliances. The Heat & Glo gas appliance you haveselected is designed to provide the utmost in safety,reliability, and efficiency.

As the owner of a new appliance, you’ll want to read andcarefully follow all of the instructions contained in thisOwner’s Manual. Pay special attention to all Cautionsand Warnings.

This Owner’s Manual should be retained for future reference.We suggest that you keep it with your other importantdocuments and product manuals.

The information contained in this Owner’s Manual, unlessnoted otherwise, applies to all models and gas controlsystems.

Your new Heat & Glo gas appliance will give you years ofdurable use and trouble-free enjoyment. Welcome to the Heat& Glo family of appliance products!

Read this manual before installing or operating this appliance.Please retain this owner’s manual for future reference.

We recommend that you record the followingpertinent information about your appliance.

Gas and ElectricInformation

Model Number

Serial Number

Type of Gas

The model information regarding your specific appliance can be found onthe rating plate usually located in the control area of the appliance.

Homeowner Reference Information

Heat & Glo, a of Hearth & Home Technologies, Inc.brand20802 Kensington Boulevard, Lakeville, MN 55044

Not for use with solid fuel.(Ne doit pas entre utilise avec un combustible solide).

This appliance must be installed in accordance with local codes, if any; if not, follow ANSI Z223.1in the USA or CAN/CGA B149 installation codes. (Installer l’appareil selon les codes ou reglementslocaux ou, en l’absence de tels reglements, selon les codes d’installation CAN/CGA-B149.)

Type of Gas (Sorte De Gaz):

NATURAL GAS

MADE IN USA

Minimum Permissible Gas Supply for Purposes of Input Adjustment.Approved Minimum (De Gaz) Acceptable 0.0 in w.c. (Po. Col. d’eau)Maximum Pressure (Pression) 0.0 in w.c. (Po. Col. d’eau)Maximum Manifold Pressure (Pression) 0.0 in w.c. (Po. Col. d’eau)Minimum Manifold Pressure (Pression) 0.0 in w.c. (Po. Col. d’eau)

Model:(Modele):

Serial(Serie):

ANSI Z21XX-XXXX · CSA 2.XX-MXX · UL307B

XXXXXXXXIN CANADA

ALTITUDE: 0-0000 FT. 0000-0000FT.MAX. INPUT BTUH: 00,000 00,000MIN. INPUT BTUH: 00,000 00,000ORIFICE SIZE: #XXXXX #XXXXX XXXXXXXX

Total Electrical Requirements: 000Vac, 00Hz., less than 00 Amperes

This product may be covered by one or more of the following patents: (Nos produits sont couverts par un ou plusieurs des brevets suivants): (United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471, 5328356, 5341794, 5347983, 5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165, 6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, D320652, D445174, D462436; (Canada)1297749, 2195264, 2225408; or other U.S. and foreign patents pending (ou autres brevets americains et etrangers en attente).

Where everything comes together

Page 3: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/05 3

- Table of Contents -

! = Contains updated information.

Section 9: Gas InformationA. Fuel Conversions .................................... 23B. Gas Pressures ........................................ 23C. Gas Connection ....................................... 23

Section 10: Electrical InformationA. Recommendation for Wire ...................... 25B. Connecting to the Appliance .................... 25C. Wall Switch .............................................. 25D. Intellifire Ignition System Wiring .............. 25E. Junction Box Installation .......................... 28F. Installing Flame Control Solenoid .......... 28

Section 11: FinishingA. Facing Material ........................................ 29B. Cabinets .................................................. 29C. Mantel Projections ................................... 29

Section 12: Appliance SetupA. Remove Shipping Materials .................... 30B. Clean the Appliance ................................. 30C. Accessories ............................................. 30D. Ember Placement .................................... 30E. Positioning the Logs ............................... 31F. Glass Assembly ....................................... 32G. Air Shutter Settings .................................. 32

Section 13: Operating InstructionsA. Before Lighting Appliance ........................ 33B. Lighting Appliance ................................... 34C. After Appliance is Lit ................................. 35D. Frequently Asked Questions ................... 35

Section 14: TroubleshootingA. Intellifire Ignition System ......................... 36

Section 15: Maintaining and Servicing Appliance. ........... 38A. Replacing Light Bulbs ............................... 39

Section 16: Reference MaterialsA. Appliance Dimension Diagram ............... 41B. Vent Components Diagrams ................... 42C. Service Parts ............................................ 44D. Warranty ................................................... 47E. Contact Information .................................. 48

Section 1: Listing and Code ApprovalsA. Appliance Certification .................................. 4B. Glass Specifications ...................................... 4C. BTU Specifications ........................................ 4D. High Altitude Installations .............................. 4

Section 2: Getting StartedA. Design and Installation Considerations ........ 5B. Tools and Supplies Needed .......................... 5C. Inspect Appliance and Components ............. 5

Section 3: Framing and ClearancesA. Selecting Appliance Location ....................... 6B. Cabinets ....................................................... 6C. Mantel Projections ........................................ 6D. Constructing the Appliance Chase .............. 7E. Clearances ................................................... 7

Section 4: Termination LocationsA. Vent Termination Minimum Clearances ...... 8

Section 5: Vent Information and DiagramsA. Vent Table Key ............................................ 10B. Use of Elbows ............................................ 10C. Measuring Standards ................................. 10D. Vent Diagrams ............................................ 11

Section 6: Vent Clearances and FramingA. Pipe Clearances to Combustibles ............ 15B. Wall Penetration Framing .......................... 15C. Vertical Penetration Framing ...................... 16

Section 7: Appliance PreparationA. Top Vent ...................................................... 17B. Securing and Leveling the Appliance ......... 24

Section 8: Installing Vent PipeA. Assembly of Vent Sections ......................... 19B. Installing Firestops & Termination Cap ..... 20D. Installing Roof Flashing and Vertical

Termination Cap ......................................... 21

"

!

!""

Page 4: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/054

B. Glass SpecificationsHearth & Home Technologies appliances manufactured withtempered glass may be installed in hazardous locationssuch as bathtub enclosures as defined by the ConsumerProduct Safety Commission (CPSC). The tempered glasshas been tested and certified to the requirements of ANSIZ97.1 and CPSC 16 CFR 1202 (Safety Glazing CertificationCouncil SGCC# 1595 and 1597. Architectural Testing, Inc.Reports 02-31919.01 and 02-31917.01).

This statement is in compliance with CPSC 16 CFR Section1201.5 “Certification and labeling requirements” which refersto 15 U.S. Code (USC) 2063 stating “…Such certificateshall accompany the product or shall otherwise be furnishedto any distributor or retailer to whom the product is delivered.”

Some local building codes require the use of tempered glasswith permanent marking in such locations. Glass meetingthis requirement is available from the factory. Please contactyour dealer or distributor to order.

A. Appliance Certification

NOTE: This installation must conform with local codes. In theabsence of local codes you must comply with the NationalFuel Gas Code, ANSI Z223.1-latest edition in the U.S.A.and the CAN/CGA B149 Installation Codes in Canada.

NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.This appliance is tested and approved as either supplemen-tal room heat or as a decorative appliance. It should not befactored as primary heat in residential heating calculations.

Listing and Code Approvals

D. High Altitude InstallationsU.L. Listed gas appliances are tested and approved withoutrequiring changes for elevations from 0 to 2000 feet in theU.S.A. and Canada.

When installing this appliance at an elevation above 2000feet, it may be necessary to decrease the input rating bychanging the existing burner orifice to a smaller size. Inputrate should be reduced by 4% for each 1000 feet above a2000 foot elevation in the U.S.A., or 10% for elevationsbetween 2000 and 4500 feet in Canada. If the heating valueof the gas has been reduced, these rules do not apply. Toidentify the proper orifice size, check with the local gasutility.

If installing this appliance at an elevation above 4500 feet(in Canada), check with local authorities.

C. BTU Specifications

1

WARNINGDo NOT use this appliance if any part has been underwater. Immediately call a qualified service technician toinspect the appliance and to replace any part of the controlsystem and any gas control which has been under water.

This product is listed to ANSI standards for “Vented GasAppliance Heaters” and applicable sections of “Gas Burn-ing Heating Appliances for Manufactured Homes and Rec-reational Vehicles”, and “Gas Fired Appliances for Use atHigh Altitudes”.

Heat & Glo Quality Systemsregistered by SGS ICS

Models(U.S. or Canada)

MaximumInput BTUH

MinimumInput BTUH

OrificeSize

(DMS)

Soho24 (NG)US 12,000 8,500 51

CAN 10,800 7,650 52

Soho24LPUS 12,000 N/A 60

CAN 10,800 N/A 61

MODELS: Soho24, Soho24LP

LABORATORY: Underwriters Laboratories, Inc. (UL)

TYPE: Direct Vent Gas Appliance Heater

STANDARD: ANSI Z21.88-2000•CSA2.33-M98•UL307B

Page 5: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/05 5

A. Design and Installation ConsiderationsHeat & Glo direct vent gas appliances are designed to op-erate with all combustion air siphoned from outside of thebuilding and all exhaust gases expelled to the outside. Noadditional outside air source is required.

Getting Started

C. Inspect Appliance and Components

2

When planning an appliance installation, it’s necessary todetermine the following information before installing:

• Where the appliance is to be installed.

• The vent system configuration to be used.

• Gas supply piping.

• Electrical wiring.

• Framing and finishing details.

• Whether optional accessories—devices such as a fan,wall switch, or remote control—are desired.

B. Tools and Supplies NeededBefore beginning the installation be sure that the followingtools and building supplies are available.

Reciprocating saw Framing materialPliers Hi temp caulking materialHammer GlovesPhillips screwdriver Framing squareFlat blade screwdriver Electric drill and bits (1/4 in.)Plumb line Safety glassesLevel 1/2 - 3/4 inch length, #6 or #8 Self-drilling screwsManometer VoltmeterTape measure Noncorrosive leak check solution

• Carefully remove the appliance and components fromthe packaging.

• The vent system components and trim doors are shippedin separate packages.

• The gas logs may be packaged separately and must befield installed.

• Report to your dealer any parts damaged in shipment,particularly the condition of the glass.

• Read all of the instructions before starting the in-stallation. Follow these instructions carefully dur-ing the installation to ensure maximum safety andbenefit.

Check building codes prior to installation.• Installation MUST comply with local, regional, state

and national codes and regulations.• Consult local building, fire officials or authorities

having jurisdiction about restrictions, installationinspection, and permits.

CAUTION

Keep appliance dry.• Mold or rust may cause odors.• Water may damage controls.

WARNING

Inspect appliance and components fordamage. Damaged parts may impair safeoperation.

WARNING

• Do NOT install damaged components.• Do NOT install incomplete components.• Do NOT install substitute components.

Report damaged parts to dealer.

Hearth & Home Technologies disclaimsany responsibility for, and the warranty willbe voided by, the following actions:

WARNING

• Installation and use of any damaged appliance or ventsystem component.

• Modification of the appliance or vent system.

• Installation other than as instructed by Hearth & HomeTechnologies.

• Improper positioning of the gas logs or the glass door.

• Installation and/or use of any component part notapproved by Hearth & Home Technologies.

Any such action may cause a fire hazard.

Page 6: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/056

3 Framing and Clearances

NOTE:• Illustrations reflect typical installations and are FOR

DESIGN PURPOSES ONLY.• Illustrations/diagrams are not drawn to scale.• Actual installation may vary due to individual design

preference.

WARNINGFire RiskProvide adequate clearance:• Around air openings• To combustibles• For service accessLocate appliance away from traffic areas.

A. Selecting Appliance LocationWhen selecting a location for your appliance it is importantto consider the required clearances to walls (see Figure 3.1).

Figure 3.1 Framing Dimensions

A B C DInches 33-1/8 29-1/8 46-3/4 35-1/8

Millimeters 841 740 1187 892

NOTE: For actual appliance dimensions refer to Sec-tion 16.

In addition to these framing dimensions, also reference the following sections:• Clearances and Mantel Projections (Section 3.B)• Vent Clearances and Framing (Section 6).

BC

A

A

1/2 IN.

ALCOVEINSTALLATION

TOP VENT,ONE 90 ELBOW0

B

D

B. CabinetsThe Greenwich cabinet system is designed with built-in heatshields and baffles, and is made specifically for SOHO24.Greenwich installs require a Firescreen front. No other frontis compatible.

If any cabinetry is desired other than Greenwich, clearancesto combustibles MUST be followed as shown in Figures 3.1and 3.2 (Studio 24 front must be used and no mantels areallowed).

C. Mantel ProjectionsStudio 24 front is required for all installs except where Green-wich cabinet is used. No mantels are allowed when usingStudio 24 fronts.

"

"

Page 7: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/05 7

D. Constructing the Appliance ChaseA chase is a vertical boxlike structure built to enclose thegas appliance and/or its vent system. Vertical vents that runon the outside of a building may be, but are not required tobe, installed inside a chase.

Construction of the chase may vary with the type of building.These instructions are not substitutes for the requirements oflocal building codes. Local building codes MUST be checked.

Chases should be constructed in the manner of all outsidewalls of the home to prevent cold air drafting problems. Thechase should not break the outside building envelope in anymanner.

Walls, ceiling, base plate and cantilever floor of the chaseshould be insulated. Vapor and air infiltration barriers shouldbe installed in the chase as per regional codes for the rest ofthe home. Additionally, in regions where cold air infiltrationmay be an issue the inside surfaces may be sheetrockedand taped for maximum air tightness.

To further prevent drafts, the firestops should be caulkedwith high temperature caulk to seal gaps. Gas line holesand other openings should be caulked with high temp caulkor stuffed with unfaced insulation. If the appliance is beinginstalled on a cement slab, a layer of plywood may be placedunderneath to prevent conducting cold up into the room.

E. Clearances

Figure 3.2 Clearances to Combustibles

Fire Risk.Odor Risk.• Install appliance on hard metal or wood

surfaces extending full width and depth ofappliance.

WARNING

CLEARANCES TO COMBUSTIBLES:

A B C D E F G H I JRough

Opening (Vent Pipe)

RoughOpening(Height)

RoughOpening(Depth)

RoughOpening(Width)

MinimumPlatformHeight

Clearanceto Ceiling

Non-CombustibleFloor

CombustibleFlooring

BehindAppliance

Sides ofAppliance

Inches 8-5/8 44 11-1/2 29-5/8 3 28 0 0 1/2 1/2mm 219 1118 292 752 76 711 0 0 13 13

Fire Risk.• Construct chase to all clearance

specifications in manual.• Locate and install appliance to all

clearance specifications in manual

WARNING

H

J

I

F

G

B

C

D

A

E

CAUTIONThe Soho24 requires an elevated platform constructionto accommodate the Studio 24 Front which is largerthan the appliance.

• Do NOT install appliance directly on carpeting, vinyl,tile or any combustible material other than wood.

Page 8: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/058

A. Vent Termination Minimum Clearances

Fire Risk.Explosion Risk.Maintain vent clearance to combustiblesas specified.

WARNING

• Do not pack air space with insulation orother materials.

Failure to keep insulation or other materialsaway from vent pipe may cause fire.

Roof Pitch H (Min.) Ft.Flat to 6/12 .......................................................... 1.0*Over 6/12 to 7/12 ............................................... 1.25*Over 7/12 to 8/12 ............................................... 1.5*Over 8/12 to 9/12 ............................................... 2.0*Over 9/12 to 10/12 ............................................. 2.5Over 10/12 to 11/12 ........................................... 3.25Over 11/12 to 12/12 ........................................... 4.0Over 12/12 to 14/12 ........................................... 5.0Over 14/12 to 16/12 ........................................... 6.0Over 16/12 to 18/12 ........................................... 7.0Over 18/12 to 20/12 ........................................... 7.5Over 20/12 to 21/12 ........................................... 8.0

Figure 4.1Figure 4.2 Minimum Height from Roof to Lowest Discharge Opening

Termination Locations4

Measure horizontal clearances from this surface.

Measure vertical clearances from this surface.

Figure 4.3 Multiple Vertical Termination

Figure 4.2 specifies minimum vent heights for variouspitched roofs.

(See Figure 4.4 for specific clearances)* 3 foot minimum in snow regions

GAS, WOOD or FUELOIL TERMINATION 2 FT.

(MINIMUM) TOPERPENDICULARWALL (GAS ONLY)

18 IN.

A

GASTERMINATION

Gas Termination Wood & Fuel Oil TerminationA 6 in. 24 in.

HORIZONTALOVERHANG

VERTICALWALL

TERMINATIONCAP

12X

ROOF PITCHIS X/ 12

LOWEST DISCHARGE

OPENING

H (MIN.) - MINIMUM HEIGHT FROM ROOFTO LOWEST DISCHARGE OPENING

2 FT.MIN.

2 FEET

Page 9: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/05 9

V = VENT TERMINAL X = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTED

Figure 4.4 Vent Termination Minimum Clearances

A = 12 inches ............ clearances above grade, veran-da, porch, deck or balcony

B = 12 inches ............ clearances to window or doorthat may be opened, or to per-manently closed window. (Glass)

D* = 18 inches ............. vertical clearance to unventilat-ed soffit or to ventilated soffit lo-cated above the terminal

*30 inches ............ for vinyl clad soffits and belowelectrical service

F = 9 inches .............. clearance to outside cornerG = 6 inches ............... clearance to inside cornerH = 3 ft. (Canada) ...... not to be installed above a gas

meter/regulator assembly within 3feet (90cm) horizontally from thecenter-line of the regulator

I = 3 ft. (U.S.A.)6 ft. (Canada) ....... clearance to gas service regula-

tor vent outletJ = 9 inches (U.S.A.)

12 inches (Canada)clearance to non-mechanical airsupply inlet to building or thecombustion air inlet to any otherappliance

K = 3 ft. (U.S.A.)6 ft. (Canada) ......... clearance to a mechanical

(powered) air supply inletL** = 7 ft. ......................... clearance above paved side-

walk or a paved driveway lo-cated on public property

M*** = 18 inches .............. clearance under veranda, porch,deck, balcony or overhang

42 inches .............. vinyl

CAUTION: IF EXTERIOR WALLS ARE FINISHED WITH VINYL SIDING, IT IS SUGGESTED THAT A VINYL PROTECTOR KIT BE INSTALLED.

** a vent shall not terminate directly above a sidewalk or paveddriveway which is located between two single family dwellings andserves both dwellings.

*** only permitted if veranda, porch, deck or balcony is fully open ona minimum of 2 sides beneath the floor, or meets Note 2.

NOTE 1: On private property where termination is less than 7 feetabove a sidewalk, driveway, deck, porch, veranda or balcony, use ofa listed cap shield is suggested. (See vents components page)

NOTE 2: Termination in an alcove space (spaces open only on one sideand with an overhang) are permitted with the dimensions specified forvinyl or non-vinyl siding and soffits. 1. There must be 3 feet minimumbetween termination caps. 2. All mechanical air intakes within 10 feetof a termination cap must be a minimum of 3 feet below the terminationcap. 3. All gravity air intakes within 3 feet of a termination cap must bea minimum of 1 foot below the termination cap.

MN

PR

Q

(See Note 1)

(See Note 1)

(See Note 2)

ElectricalService

V

SV S

V

T

D*

V

NOTE 3: Local codes or regulations may require differentclearances.

NOTE 4: Termination caps may be hot. Consider their proximityto doors or other traffic areas.

NOTE 5: Location of the vent termination must not interfere withaccess to the electrical service.

WARNING: In the U.S: Vent system termination is NOT permit-ted in screened porches. You must follow side wall, overhangand ground clearances as stated in the instructions.

In Canada: Vent system termination is NOT permitted in screenedporches. Vent system termination is permitted in porch areas withtwo or more sides open. You must follow all side walls, overhangand ground clearances as stated in the instructions.

Heat & Glo assumes no responsibility for the improper perfor-mance of the appliance when the venting system does not meetthese requirements.

DE

BL

v

v v

v

v

v

v

v

BB

A H

MX

J or K

I

A

G

F

U.S.(3 FT)B

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

______________________________________________________________________

QMIN RMAX

1 cap 3 feet 2 x Q ACTUAL

2 caps 6 feet 1 x Q ACTUAL

3 caps 9 feet 2/3 x Q ACTUAL

4 caps 12 feet 1/2 x Q ACTUAL

QMIN = # termination caps x 3 RMAX = (2 / # termination caps) x QACTUAL

N = 6 inches ................. non-vinyl sidewalls12 inches .............. vinyl sidewalls

P = 8 ft.

Alcove Applications

S = 6 inches ................. clearance from sides ofelectrical service

T = 12 inches ................ clearance above electricalservice

(See Note 5)

(See Note 5)

Page 10: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/0510

5 Vent Information and Diagrams

Fire Hazard.Explosion Risk.Asphyxiation Risk.Do NOT connect this gas appliance to achimney flue serving a separate solid-fuel orgas burning appliance.• Vent this appliance directly outside.• Use separate vent system for this

appliance.May impair safe operation of this appliance orother appliances connected to the flue.

WARNING

CAUTIONALL vent configuration specifications MUST be followed.• This product is tested and listed to these

specifications.• Appliance performance will suffer if specifications are

not followed.

B. Use of Elbows

Diagonal runs have both vertical and horizontal vent as-pects when calculating the effects. Use the rise for the ver-tical aspect and the run for the horizontal aspect (see Fig-ure 5.1).

Two 450 elbows may be used in place of one 900 elbow. On450 runs, one foot of diagonal is equal to 8.5 inches hori-zontal run and 8.5 inches vertical run. A length of straightpipe is allowed between two 450 elbows (see Figure 5.1).

Figure 5.1

A. Vent Table KeyThe abbreviations listed in this vent table key are used inthe vent diagrams.

Symbol Description

V1 First section (closest to appliance) of vertical length

V2 Second section of vertical length

H1 First section (closest to appliance) of horizontal length

H2 Second section of horizontal length

C. Measuring StandardsVertical and horizontal measurements listed in the ventdiagrams were made using the following standards.

1. Pipe measurements are shown using the effective lengthof pipe (see Figure 5.2).

2. Measurements are made from the appliance outer wrap,not from the standoffs.

3. Horizontal terminations are measured to the outsidemounting surface (flange of exterior firestop) (see Fig-ure 4.1).

4. Vertical terminations are measured to bottom of termi-nation cap.

VERTICAL

HORIZONTAL

EffectiveHeight/Length

Figure 5.2 SL Pipe Effective Length

PipeSL-06D 5-3/4SL-09D 8-3/4SL-12D 11-3/4SL-12/17D 11-3/4 to 16-3/4SL-17/24D 16-3/4 to 23-3/4SL-24D 23-3/4SL-36D 35-3/4SL-48D 47-3/4

Length/Inches

Page 11: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/05 11

Figure 5.3

Figure 5.4

D. Vent Diagrams

Fire Risk. Explosion Risk.Do NOT pack insulation or other combustibles between firestops.• ALWAYS maintain specified clearances around venting and firestop systems.• Install firestops as specified.Failure to keep insulation or other material away from vent pipe may cause fire.

WARNING

1. Top Vent - Horizontal Termination

One Elbow

Two Elbows

V1 Minimum H1 Maximum

Elbow only 2-1/2 ft 762 mm1 ft 305 mm 2-1/2 ft 762 mm

1-1/2 ft 457 mm 3-1/2 ft 1.1 m2-1/2 ft 762 mm 5-1/2 ft 1.7 m3-1/2 ft 1.1 m 7-1/2 ft 2.3 m4-1/2 ft 1.4 m 15-1/2 ft 4.7 m

V1 + H1 = 39 ft (11.9m) MaximumH1 = 15-1/2 ft (4.6m) Maximum

V1

H1

V1 Minimum H1 + H2 Maximum2 - 900 elbowsback to back Cannot do

6 in 152 mm 1 1/2 ft 457 mm

1-1/2 ft 457 mm 2-1/2 ft 762 mm

2-1/2 ft 762 mm 4-1/2 ft 1.4 m

3-1/2 ft 1.1 m 6-1/2 ft 1.9 mV1 + H1+ H2 = 48 ft (14.6 m) MaximumH1 + H2 = 15-1/5 ft (4.7 m) Maximum

H2 H1

V1

INSTALLEDHORIZONTALLY

Page 12: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/0512

Figure 5.5

1. Top Vent - Horizontal Termination - (continued)

Three ElbowsV1 Min. H1 Max. V2 Min. H2 Max.

Elbow only 2 ft 610 mm * = V2

1 ft 304 mm 2 ft 610 mm * = V2

1-1/2 ft 457 mm 3 ft 914 mm * = V2

2-1/2 ft 762 mm 5 ft 1.5 m * = V2

3-1/2 ft 1.1 m 7 ft 2.1 m * = V2

4-1/2 ft 1.4 m 15 ft 4.6 m * = V2

*When using V2 , H2 Max = V2. If V2 = 0, then H2 Max = 1-1/2 ft (38 mm)(H1 + H2 ) cannot exceed 15 ft (4.6 m) when using appropriate V2.

H1

V2

H2

V1

Page 13: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/05 13

2. Top Vent - Vertical Termination

No Elbow

Figure 5.6

Figure 5.7

Two Elbows

V1 = 45 ft Max. (13.72 m)V1 = 3 ft Min. (914 mm)

NOTE: If installing a vertical vent/termination off the top of the ap-pliance, the optional vertical ter-mination baffle should be usedfor runs of 25 feet or greater.

V1

V1 H1 Maximum V2 V1 + V2 MinimumOne Elbow 1-1/2 ft 457 mm * * *

1/2 ft 152 mm 2 ft 610 mm * * *1-1/2 ft 457 mm 3 ft 914 mm * * *2-1/2 ft 762 mm 5 ft 1.5 m3-1/2 ft 1.1 m 7 ft 2.1 m5-1/2 ft 1.7 m 15 ft 4.6 m

V1 + V2 + H1 = 38 ft (11.6 m) Max.*No specific restrictions on this value EXCEPT

V1 + V2 + H1 cannot exceed 50 ft (15.2m)

V1

H1

V2

Page 14: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/0514

Figure 5.8

2. Top Vent - Vertical Termination - (continued)

Three ElbowsV1 H1+ H2 V2 V1+ V2 Minimum

Elbow only 1/2 ft. 152 mm * * *

1/2 ft. 152 mm 1 ft. 305 mm * * *

1-1/2 ft. 457 mm 2 ft. 610 mm * * *

2-1/2 ft. 762 mm 4 ft. 1.2 m * * *

3-1/2 ft. 1.1 m 6 ft. 1.8 m * * *

4-1/2 ft. 1.4 m 14 ft. 4.3 m * * *H1 + H2 = 14 ft (4.3 m) Maximum

V1 + V2 + H1 + H2 = 37 ft (11.3 m) Maximum

H1

V2

H2

V1

INSTALLEDHORIZONTALLY

Page 15: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/05 15

A. Pipe Clearances to Combustibles

Vent Clearances and Framing6

Combustible Wall PenetrationFrame a hole in a combustible wall for an interior wall shield,(Figure 6.2) whenever a wall is penetrated. Use same sizeframing materials as those used in the wall construction.The wall shield maintains minimum clearances and pre-vents cold air infiltration.

Non-Combustible Wall PenetrationIf the hole being penetrated is surrounded by noncombus-tible materials such as concrete, a hole with diameter oneinch greater than the pipe is acceptable.

Fire Risk.Explosion Risk.Maintain vent clearance to combustiblesas specified.

WARNING

• Do not pack air space with insulation orother materials.

Failure to keep insulation or other materialsaway from vent pipe may cause fire.

B. Wall Penetration Framing

Figure 6.1 Pipe Clearances

1 in. CLEARANCEAROUND VERTICAL

SECTIONS

3 in. TOPCLEARANCE

1 in. SIDE ANDBOTTOM CLEARANCE

Figure 6.2 Exterior Wall Hole

A

B

A* B 38 in. 37 in.

* Shows center of vent framing hole for top venting.The center of the hole is one (1) inch (25.4mm)above the center of the horizontal vent pipe.

NOTE: Slopenot required.

Page 16: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/0516

C. Vertical Penetration Framing

Installing the Firestop Spacer

• Frame an opening 10 inches by 10 inch-es whenever the vent system pene-trates a ceiling/floor (see Figure 6.3).

• Frame the area with the same sized lum-ber as used in ceiling/floor joist.

• When installing a top vent vertical appli-ance the hole should be directly abovethe appliance, unless the flue is offset.

• Do not pack insulation around the vent.Insulation must be kept away from thepipe.

Figure 6.3

ATTICABOVE

A

B

WARNINGFire Hazard

Keep loose materials orblown insulation from touch-ing the vent pipe.

Installing Attic Shield

Note: The firestop spacer is not required ifattic shield is used.

• Frame opening for attic shield.

• Attic shield may be installed above orbelow ceiling (see Figure 6.4).

• Secure with three fasteners on eachside.

• Fold tabs at top of attic shield in towardvent pipe. Tabs must keep vent pipecentered within shield.

• Field construct additional shield heightif insulation is deeper than height of at-tic shield.

Figure 6.4 Installing the Attic Shield

• National building codes recommend us-ing attic shield to keep loose materials/blown insulation from contacting vent.

• Hearth & Home Technologies requiresthe use of an attic shield.

3 FASTENERSPER SIDE

BEND TABS INAROUND PIPE

ATTIC SHIELD INSTALLEDBELOW CEILING

ATTIC SHIELD INSTALLEDABOVE CEILING

A B 10 in. 10 in.

SL-DPIPE

Page 17: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/05 17

Appliance Preparation7A. Top Vent

Step 2. Remove vent gasketing from manual bag andplace over vent hole.

Step 3. Place first section of pipe such that gasket isengaged.

Step 4. Fold elbow heat shield and place over elbow.

Step 1. Remove elbow heat shield by removing two screwsfrom sides of appliance.

Step 5. Screw elbow heat shield to appliance top with self-tapping screws removed in Step 1.

CAUTIONSharp Edges• Wear protective gloves

and safety glassesduring installation.

FRONTVIEW

REARVIEW

Figure 7.4

If venting with 90 degree elbow off top, follow Steps 4 and5. If using vertical pipe off top, discard elbow heat shield.

Figure 7.6Figure 7.3

Figure 7.2

Figure 7.1

Page 18: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/0518

B. Securing and Leveling the Appliance

The diagram shows how to properly position, level, and se-cure the appliance (see Figure 7.7). Nailing tabs are provid-ed to secure the appliance to the framing members.

• Place the appliance into position.

• Level the appliance from side to side and front to back.

• Shim the appliance with noncombustible material, suchas sheet metal, as necessary.

• Bend out nailing tabs on each side.

• Keep nailing tabs flush with the framing.

• Secure the appliance to the framing by using nails orscrews through the nailing tabs.

Figure 7.7 Proper Positioning, Leveling and Securing of a Appliance

Fire Risk.• Prevent contact with sagging, loose

insulation.• Do NOT install against vapor barriers or

exposed insulation.

WARNING

WARNINGFire Risk.• ALWAYS maintain specified

clearances around the appliance.• Do NOT notch into the framing around the appliance spacers.Failure to keep insulation, framing or other material awayfrom the appliance may cause fire.

NOTE: Once appliance is setup for top or rear venting, itCANNOT be changed at a later time. NAILING TABS

(BOTH SIDES)

Page 19: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/05 19

A. Assembly of Vent Sections

Installing Vent Pipe8

For Vertical Runs - The vent system must be supportedevery eight (8) feet (2.4m) above the appliance flue outletby wall brackets. To install support brackets for vertical runs:• Attach wall brackets to the vent pipe and secure the wall

bracket to the framing members with nails or screws.

Continue Adding Vent Components• Continue adding vent components, locking each succeed-

ing component into place.

• Ensure that each succeeding vent component is secure-ly fitted and locked into the preceding component.

• 90° elbows may be installed and rotated to any pointaround the preceding component’s vertical axis. If an el-bow does not end up in a locked position with the pre-ceding component, attach with a minimum of two (2)sheet metal screws.

Figure 8.1 Adding Venting Components

Install Support BracketsFor Horizontal Runs - The vent system must be supportedevery five (5) feet of horizontal run by a horizontal pipe support.To install support brackets for horizontal runs:• Place the pipe supports around the vent pipe.• Nail the pipe supports to the framing members.

Attach the First Vent Component to Starting CollarsTo attach the first vent component to the starting collarsof the appliance:

• Lock the vent components into place by sliding the con-centric pipe sections with four (4) equally spaced interiorbeads into the appliance collar or previously installed com-ponent end with four (4) equally spaced indented sections.

• When the internal beads of each outer pipe line up, ro-tate the pipe section clockwise about one-quarter (1/4)turn (see Figure 8.1). The vent pipe is now locked together.

• Slide the ceramic fiber pad over the first vent section andplace it flush to the appliance. This will prevent cold airinfiltration. High temp caulk may be used to hold the partin place. Continue to add vent components.

Fire RiskExhaust Fumes RiskImpaired Performance of Appliance

WARNING

• Ensure vent components are locked together correctly.• Pipe may separate if not properly joined.

Fire Risk.Explosion Risk.Combustion Fume Risk.Use vent run supports per installationinstructions.Connect vent sections per installationinstructions.• Maintain all clearances to combustibles.• Do NOT allow vent to sag below

connection point to appliance.• Maintain specified slope (if required).

WARNING

Improper support may allow vent to sag or separate.

Page 20: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/0520

B. Installing Firestops and Horizontal Termination Cap

Do NOT connect a pipe section to a termination cap with-out using the telescoping flue section found on the termi-nation cap.

WARNING

NOTE: Where required, an exterior wall flashing isavailable.When penetrating a brick wall, a brick extension kitis available for framing the brick.

Installing the Horizontal Termination Cap

Vent termination must not be recessed in the wall. Sidingmay be brought to the edge of the cap base.

Caulk the outside edges of the cap.

When installing a horizontal termination cap, follow thecap location guidelines as prescribed by current ANSIZ223.1 and CAN/CGA-B149 installation codes.

Burn Risk• Local codes may require installation of

a cap shield to prevent anything oranyone from touching the hot cap.

WARNING

Figure 8.2 Hole and Vent Pipe

Figure 8.3 Heat Shield, Interior & Exterior Firestops

TRIM HEATSHIELD IF TOOLONG, ADD TO SHIELD IF TOOSHORT

EXTERIORFIRESTOP

INTERIORFIRESTOP

HEAT SHIELD

Fire RiskExhaust Fumes RiskImpaired Performance of Appliance

WARNING

• Ensure vent components are locked together correctly.• Pipe may separate if not properly joined.

• Position the firestops on both sides of the hole previ-ously cut and secure the firestops with nails or screws.

• The heat shields of the firestops MUST BE placed to-wards the top of the hole.

• Continue the vent run through the firestops.

For Horizontal Runs - Firestops are REQUIRED on bothsides of a combustible wall through which the vent passes.NOTE: Model SLK-01TRD does not need an exteriorfirestop on an exterior combustible wall.To install firestops for horizontal runs that pass througheither interior or exterior walls:

Cut a 10” x 10” (254mm x 254mm) hole for SL-D-seriespipe. The center of the framing hole is one (1) inch (25.4mm)above the center of the horizontal vent pipe.

Fire Risk. Explosion Risk.Do NOT pack insulation orother combustibles betweenfirestops.

WARNING

• ALWAYS maintain specified clearances around vent-ing and firestop systems.

• Install firestops as specified.Failure to keep insulation or other material away fromvent pipe may cause fire.

VENT PIPE

1" (25.4 mm)

10"(254mm)

10"(254mm)

Page 21: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/05 21

D. Installing Roof Flashing and Vertical Termination CapTo install roof flashing see Figure 8.4.For installation of vertical termination cap see minimum ventheights for various pitched roofs (see Figure 8.4) .

To attach the vertical termination cap, slide the inner collarof the cap into the inner flue of the pipe section and placethe outer collar of the cap over the outer flue of the pipesection.

Secure with three screws into the outer flue. Secure the capby driving the three self-tapping screws (supplied) throughthe pilot holes in the outer collar of the cap into the outer flueof the pipe (see Figure 8.5).

Roof Pitch H (Min.) Ft.Flat to 6/12 ...................................... 1.0*6/12 to 7/12 .................................. 1.25*Over 7/12 to 8/12 ........................... 1.5*Over 8/12 to 9/12 ........................... 2.0*Over 9/12 to 10/12 .......................... 2.5Over 10/12 to 11/12 ...................... 3.25Over 11/12 to 12/12 ........................ 4.0Over 12/12 to 14/12 ........................ 5.0Over 14/12 to 16/12 ........................ 6.0Over 16/12 to 18/12 ........................ 7.0Over 18/12 to 20/12 ........................ 7.5Over 20/12 to 21/12 ........................ 8.0

Figure 8.4 Minimum Height from Roof to Lowest Discharge Opening

* 3 foot minimum in snow regions

Fire Risk.Explosion Risk.Inspect external vent cap regularly.• Ensure no debris blocks cap.• Combustible materials blocking cap may

ignite.• Restricted air flow affects burner operation.

WARNING

HORIZONTALOVERHANG

VERTICALWALL

TERMINATIONCAP

12X

ROOF PITCHIS X/ 12

LOWEST DISCHARGE

OPENING

H (MIN.) - MINIMUM HEIGHT FROM ROOFTO LOWEST DISCHARGE OPENING

2 FT.MIN.

2 FEET

Figure 8.5

SCREWS

CAULK

STORMCOLLAR

(1 of 3)

TERMINATION CAP

Page 22: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/0522

Figure 8.6 Assembling the Storm Collar

Figure 8.7 Assembling the Storm Collar Around the Pipe

Connect both halves of the storm collar with two screws(see Figure 8.6).

Wrap the storm collar around the exposed pipe sectionand align brackets. Insert a bolt (provided) through thebrackets and tighten nut to complete storm collar assembly(see Figure 8.7).

Slide the assembled storm collar down the pipe sectionuntil it rests on the roof flashing.

Caulk around the top of the storm collar (see Figure 8.5).

CAUTIONSharp Edges• Wear protective gloves

and safety glassesduring installation.

Assembling and Installing Storm Collar

Page 23: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/05 23

NOTE: Have the gas supply line installed in accordancewith local building codes, if any. If not, follow ANSI 223.1.Installation should be done by a qualified installer approvedand/or licensed as required by the locality. (In theCommonwealth of Massachusetts installation must beperformed by a licensed plumber or gas fitter.)

A. Fuel Conversions

WARNINGFire Risk.Explosion Hazard.High pressure will damage valve.• Disconnect gas supply piping BEFORE

pressure testing gas line at test pressuresabove 1/2 psig.

• Close the manual shutoff valve BEFOREpressure testing gas line at test pressuresequal to or less than 1/2 psig.

B. Gas Pressures

C. Gas Connection

WARNINGVerify inlet pressures.• High pressure may cause overfire

condition.• Low pressure may cause explosion.• Verify minimum pressures when other

household gas appliances are operating.Install regulator upstream of valve if linepressure is greater than 1/2 psig.

Proper input pressures are required for optimum applianceperformance. Gas line sizing requirements need to be madefollowing NFPA51.

Gas Information9

NOTE: Gas line may be run from either side of theappliance provided the hole in the outer wrap does NOTexceed 2-1/2 inches in diameter and does not penetratethe firebox.

NOTE: A listed (and Commonwealth of Massachusetts ap-proved) 1/2 inch (13mm) T-handle manual shut-off valve andflexible gas connector are connected to the 1/2 inch (13mm)control valve inlet.• If substituting for these components, please consult

local codes for compliance.

Pressure requirements for appliance are shown in the tablebelow. Minimum pressures must be met when otherhousehold gas appliances are operating.

Pressure Natural Gas PropaneMinimum 5.0 inches 11.0 inchesInlet Pressure w.c. w.c.Maximum Inlet 14.0 inches 14.0 inchesGas Pressure w.c. w.c.Manifold 3.5 inches 10.0 inchesPressure w.c. w.c.

Before making gas connections ensure that appliancebeing installed is compatible with the available gas type.

Any natural or propane gas conversions necessary to meetthe appliance and locality needs must be made by a quali-fied technician using Hearth & Home Technologies speci-fied and approved parts.

Refer to Reference Section 16 for location of gas line ac-cess in appliance.

WARNINGGas Leak Risk• Support control when attaching pipe to

prevent bending gas line.

Page 24: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/0524

WARNINGFire hazard.Do NOT change the valve settings.• This valve has been preset at the factory.• Changing valve settings may result in fire

hazard or bodily injury.

HIGH ALTITUDE INSTALLATIONSU.L. Listed gas appliances are tested and approvedwithout requiring changes for elevations from 0 to2000 feet in the U.S.A. and Canada.

When installing this appliance at an elevation above2000 feet, it may be necessary to decrease the inputrating by changing the existing burner orifice to asmaller size. Input rate should be reduced by 4% foreach 1000 feet above a 2000 foot elevation in theU.S.A., or 10% for elevations between 2000 and 4500feet in Canada. If the heating value of the gas hasbeen reduced, these rules do not apply. To identifythe proper orifice size, check with the local gas utility.

If installing this appliance at an elevation above 4500feet (in Canada), check with local authorities.

• Ensure that gas line does not come in contact with outerwrap of appliance. Follow local codes.

• Incoming gas line should be piped into the valve com-partment and connected to the 1/2 inch connection onthe manual shutoff valve.

CHECK FOR GAS LEAKSExplosion RiskFire RiskAsphyxiation Risk• Check all fittings and connections.• Do not use open flame.• After the gas line installation is complete,

all connections must be tightened andchecked for leaks with a commercially-

WARNING

WARNINGFire or Explosion Hazard• Gas buildup during line purge may ignite.• Purge should be performed by qualified technician.• Ensure adequate ventilation.• Ensure there are no ignition sources such as

sparks or open flames.

• A small amount of air will be in the gas supply lines.When first lighting appliance it will take a short time forair to purge from lines. When purging is complete theappliance will light and operate normally.

available, non-corrosive leak check solution. Be sureto rinse off all leak check solution following testing.

Fittings and connections may have loosened duringshipping and handling.

Page 25: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/05 25

A. Recommendation for WireThis appliance requires 110-120 VAC be wired to the junctionbox for proper operation of the appliance.

Electrical Information10NOTE: This appliance must be electrically wired andgrounded in accordance with local codes or, in the absenceof local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code, CSA C221.1.

D. Intellifire Ignition System Wiring and 3 Function Circuit Board

B. Connecting to the Appliance

WARNINGWire 110V to electrical junction box.Do NOT wire 110V to valve.Do NOT wire 110V to wall switch.• Incorrect wiring will damage millivolt valves.• Incorrect wiring will override IPI safety

lockout and may cause explosion.

This appliance requires a 110 VAC supply to the appliancejunction box for operation. A wiring diagram is shown inFigure 10.1.

This appliance is equipped with an Intellifire control valvewhich operates on a 3 volt system.

This appliance is equipped with a 3 function circuit boardwhich operates on 110 VAC and 12 VDC.

This appliance is supplied with a 3 volt AC transformer anda 12 volt DC transformer, which requires the installation ofthe supplied junction box. It is highly recommended thatthe junction box be installed at this time to avoidreconstruction.

Optional Remote Control Requirements

To attach remote receiver in series with 3 function wall switchsee wiring diagram (Figure 10.2).

This appliance requires use of 3 function switch includedwith product.

Position the wall switch in the desired position on the wall.An assembly of 18 ft of 14 AWG solid copper wires is in-cluded with the fireplace to connect the wall switch to theappliance. The maximum wire length allowed is 50 feet.

CAUTIONLabel all wires prior to disconnection when servicing con-trols. Wiring errors can cause improper and dangerousoperation. Verify proper operation after servicing.

Shock hazard.• Replace damaged wire with type 105O C

rated wire.• Wire must have high temperature insulation.

WARNING

C. Wall Switch!

Page 26: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/0526

Figure 10.1 Intellifire Pilot Ignition (IPI) Wiring D

iagram - Standard M

ethod

*Note: Appliance will not operate unless properly grounded.

IGN

ITION M

OD

ULE 3 VACIN

TERM

ITTENT PILOT IG

NITO

R

VALVE

OR

G

WH

T

ORG

GRN

SWITC

H

CIRC

UIT BO

AR

D

12VDC

LIGH

T SOC

KETS

SOLEN

OID (NG

ON

LY)

J-BO

X

BLA

CK

GR

EEN

RED

YELLOW

WH

ITE

BLA

CK

BR

OW

N

BR

OW

N

MAD

E INC

ANAD

A

50-025302-D

++

P2

HI

HI12V

CO

M

C1

C2R1

P1R

EM

REM

D1

J1J1

D2

C2

K3

K2

R4

K1

R1

D3

C1

PRESS. SW

T16T15

LINE N

EU

SOLEN

OID

T13

T12

T11

1C

3

2

EMBE

R LIGH

TSH

I/LOW

T14

T13

T12

T11

T10T9

1C

OFF/O

N

32

EMBE

R

T6T5

IPI

T2T1

PLUG

-INJ-B

OX

BLA

CK W

IRE

CA

N BE

PLUG

GED

INTO

AN

Y OF #1 - #5

LOC

ATION

S O

N TH

E H

OT SID

E

WH

ITE WIR

EC

AN B

EPLU

GG

ED IN

TOA

NY O

F #1 - #5LO

CATIO

NS

ON

THE

NEU

TRAL SID

E

PLUG

-INJ-B

OX

TRA

NSFOR

MER

3 VAC

GR

OU

ND TO

FIR

EPLAC

E CH

ASSIS

S IC

AU

TION

Wire term

inal latch can become

damaged if excessive force is used

when releasing w

ire. Please use

caution in pressing retainer.

Page 27: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/05 27

Figu

re 1

0.2

Inte

llifir

e Pi

lot

Igni

tion

(IPI)

Wir

ing

Dia

gram

with

opt

iona

l re

mot

e w

ired

in

seri

es

REM

OTE

REC

EIVE

R

IGN

ITIO

N M

OD

ULE

3 VA

CIN

TER

MIT

TENT

PIL

OT

IGN

ITO

R

VALV

E

OR

G

WH

T

ORG

GRN

SWIT

CH

CIR

CU

IT B

OA

RD

12VD

CLI

GH

T SO

CK

ETS

SOLE

NO

ID (N

G O

NLY

)

J-B

OX

BLA

CK

GR

EEN

RED

YELL

OW

WH

ITE

BLA

CK

BR

OW

N

BR

OW

N

MAD

E IN

CAN

ADA

50-025302-D

++

P2

HI

HI 12V

CO

M

C1

C2 R1

P1R

EM

REM

D1

J1J1

D2

C2

K3

K2

R4

K1

R1

D3

C1

PRES

S. S

W

T16

T15

LINE

N

EU

SOLE

NO

ID

T13

T12

T11

1C

3

2

EMB

ER L

IGH

TSHI

/LO

W

T14

T13

T12

T11

T10

T9

1C

OFF

/ON

32

EMB

ER

T6T5

IPI

T2T1

PLU

G-IN

J-B

OX

BLA

CK W

IRE

CA

N B

EPL

UG

GED

INTO

AN

Y O

F #1

- #5

LOC

ATIO

NS

ON

TH

E H

OT

SID

E

WH

ITE

WIR

EC

AN

BE

PLU

GG

ED IN

TOA

NY

OF

#1 -

#5LO

CAT

ION

S O

N T

HE

NEU

TRAL

SID

E

PLU

G-IN

J-B

OX

TRA

NSFO

RM

ER3

VAC

GR

OU

ND

TO

FIR

EPLA

CE

CH

ASS

IS

SI

Page 28: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/0528

E. Junction Box Installation

If the box is being wired from the OUTSIDE of theappliance:

• Remove the cover plate located on the outershell - right side (see Figure 10.3).

• Install the supplied Romex™ connector in thecover plate.

• Loosen two screws on the Romex connector,feed the necessary length of wire through theconnector and tighten the screws.

• Make all necessary wire connections andreattach the cover plate to the outer shell.

If the box is being wired from the INSIDE of theappliance:

• Remove the screw attaching the junction boxto the outer shell, rotate the junction boxinward to disengage it from the outer shell (seeFigure 10.3).

• Pull the electrical wires from outside theappliance through this opening into the valvecompartment.

Figure 10.3 Junction Box Detail

• Loosen the two screws on the Romex connector, feed thenecessary length of wire through the connector and tighten thescrews.

• Make all necessary wire connections to the receptacle andassemble the receptacle and cover to the junction box.

NOTE: Do NOT wire110VAC to wall switch.

WH

T

WHT

BLK

BLK

14/2WG

GRN WIREINSIDE BOX

COPPERGROUND ATTACHED

TO GRN SCREW WITHGRN WIRE

Figure 10.4

1. Remove the screw and knob from the variable regulatorand discard.

2. Unscrew the nut from the regulator and discard.3. Remove the bag containing a washer and blue and red

plungers from the side of the flame control solenoid.4. Place washer on flame control solenoid (see Figure 10.4).

5. Insert the blue plunger into the flame control solenoid(see Figure 10.4).

6. Thread the flame control solenoid with correct plungerinto the thread hole in the variable regulator. Turn one totwo turns only. Do not tighten or damage may occur.

7. Connect orange wires from control box to the flame con-trol solenoid.

VARIABLE REGULATOR

GAS CONTROLVALVE

FLAME CONTROLSOLENOID

KNOB

SCREW

NUT

VARIABLE REGULATOR

JAM NUTVARIABLEREGULATOR

SOLENOID

WASHER

WASHER

PLUNGER

F. Installing Flame Control Solenoid (Natural Gas Only)

Page 29: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/05 29

Finishing

A. Facing Material

11

Figure 11.1 Noncombustible Facing Diagram

Fire Risk.

Finish all edges and fronts to clearances andspecifications listed in manual.

WARNING

• Black metal appliance front may be covered withnoncombustible material only.

• Do NOT overlap combustible materials ontoappliance front.

• Install combustible materials up to specified clearanc-es on top front and side edges.

• Seal joints between the finished wall and appliancetop and sides using only a 300oF minimum sealant.

Fire Risk.Do NOT obstruct air inlet or outlet grilles.Do NOT modify grilles.• Modifying or covering grilles could cause temperature rise and fire hazard.

WARNING

Finishing materials must not interfere with:• Air flow through grilles or louvers.• Operation of louvers or doors.• Access for service.

0”

0”0”

SEALANT MATERIAL

NON-COMBUSTIBLEBOARD

FINISH WALL MATERIAL MAY BECOMBUSTIBLE - TOP AND SIDES

B. CabinetsThe Greenwich cabinet system is designed with built-in heatshields and baffles, and is made specifically for SOHO24.Greenwich installs require a Firescreen front. No other frontis compatible.

If any cabinetry is desired other than Greenwich, clearancesto combustibles MUST be followed as shown in Figures 3.1and 3.2 (Studio 24 front must be used and no mantels areallowed).

C. Mantel ProjectionsStudio 24 front is required for all installs except where Green-wich cabinet is used. No mantels are allowed when usingStudio 24 fronts.

"

"

Page 30: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/0530

Appliance Setup12A. Remove Shipping MaterialsRemove shipping materials from inside or underneath thefirebox.

B. Clean the ApplianceClean/vacuum any sawdust that may have accumulatedinside the firebox or underneath in the control cavity.

C. AccessoriesInstall approved accessories per instructions included withaccessories. See Service Parts List for appropriate ac-cessories. Refer to Section 16.

Shock or fire risk.Use ONLY optional accessories approved forthis appliance.• Using non-listed accessories voids

warranty.• Using non-listed accessories may result in

a safety hazard.• Only Hearth & Home Technologies

approved accessories may be used safely.

WARNING

D. Ember Placement

• Follow ember placement instructionsin manual.

• Replace ember material annually.

Explosion Risk.

WARNING

Improperly placed embers interferes withproper burner operation.

Placing the Ember MaterialEmber material is shipped with this gas appliance. To placethe ember material:

Figure 12.1 Placement of Embers

• Place Mystic Embers on areas of burner away from portholes. Use this material to give the appliance a realisticash bed.

• Save the remaining ember materials for use during appli-ance servicing. The embers provided should be enoughfor 3 to 5 applications.

EMBERMATERIALMYSTIC

EMBERS

Page 31: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/05 31

Log Assembly: LOGS-Soho24

E. Positioning the LogsIf the gas logs have been factory installed they should notneed to be positioned. If the logs have been packagedseparately, refer to the following instructions.

CAUTION: Logs are fragile. Carefully remove the logs fromthe packaging.

2077-901

Step 1. Place dime size pieces of ember material about 1/2inch apart near port holes in burner top. Do not press embersinto burner ports. Cover the burner top with a single layer ofember material.

2Ash 1

1

Ash 2 Ash 3

Step 2. Place Mystic embers and mineral wool on burnertop. Keep Mystic embers at least 1/2 inch away from allburner ports.

Step 3. Place log #1 (SRV2077-700) onto burner pan suchthat left of log contacts refractory wall.

Step 4. Place log #2 (SRV2077-701) onto burner pan suchthat log #2 fits in notch of log #1 and log #2 notch fits overburner lip. Ensure burner ports are not covered by logs.

Step 5. Place ash 1 (SRV2077-702) piece onto basepanledge.

LOG #1 NOTCH

LOG #2 NOTCH

CONTACT

1

21

Figure 12.2

Figure 12.3

Figure 12.4 Figure 12.5

Figure 12.6 Figure 12.7

Page 32: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/0532

Step 6. Place ash 2 (SRV2077-703) piece onto basepanledge.

Step 7. Place ash 3 (SRV2077-704) piece onto basepanledge. Pull two logs as far forward to ash pieces as possible.This will ensure burner ports are not blocked.

Figure 12.8 Figure 12.9

Figure 12.10 Glass Assembly

F. Glass Assembly

Removing Glass AssemblyPull the two glass assembly latches out of the groove onthe glass frame. Remove glass door from the appliance(see Figure 12.10).

Replacing Glass AssemblyReplace the glass door on the appliance. Pull out and latchthe two glass assembly latches into the groove on the glassframe.

Handle glass doors with care.• Inspect the gasket to ensure it is

undamaged.• Inspect the glass for cracks, chips or

scratches.

WARNING

• Do NOT strike, slam or scratch glass.• Do NOT operate appliance with glass door removed,

cracked, broken or scratched.• Replace glass door assembly as a complete appliance.

BOTTOMLATCH

GLASSASSEMBLY

G. Air Shutter Settings

NG LP

Burner 1/8 in. 1/4 in.

Page 33: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/05 33

A. Before Lighting Appliance

Operating Instructions13Before operating this appliance have a qualifiedtechnician:• Remove all shipping materials from inside and/or

underneath the firebox.• Review proper placement of logs, mineral wool and

Mystic embers.• Check the wiring.• Check the air shutter adjustment.• Ensure that there are no gas leaks.• Ensure that the glass is sealed and in the proper

position.• Ensure that the flow of combustion and ventilation air

is not obstructed (front grilles and vent caps).

HOT! DO NOT TOUCH.SEVERE BURNS MAY RESULT.CLOTHING IGNITION MAY RESULT.

WARNING

• Keep children away.

• CAREFULLY SUPERVISE children in same room asappliance.

• Alert children and adults to hazards of hightemperatures.

• Do NOT operate with protective barriers open orremoved.

• Keep clothing, furniture, draperies and othercombustibles away.

Glass and other surfaces are hot duringoperation and cool down.

This appliance has been supplied with an integral barrierto prevent direct contact with the fixed glass panel. Do NOToperate the appliance with the protective barrier removed.Contact your dealer or Hearth & Home Technologies if thebarrier is not present or help is needed to properly install one.

Glass door must be in place whenappliance is operating.Risk of:• Combustion Fumes• FireDo NOT operate appliance with glassdoor removed.

WARNING

• Open viewing glass for servicing only.• Glass door MUST be in place and sealed before

operating appliance.• Only use glass door certified for use with appliance.• Glass replacement should be done by qualified

technician.

Improper installation, adjustment, alteration, service ormaintenance can cause injury or property damage. Referto the owner’s information manual provided with thisappliance. For assistance or additional information consulta qualified installer, service agency or the gas supplier.

WARNING

Do NOT use this appliance if any part has been under water.Immediately call a qualified service technician to inspectthe appliance and to replace any part of the control systemand any gas control which has been under water.

WARNING

Page 34: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/0534

B. Lighting Appliance

Intellifire Ignition

Final Inspection by_________________________________

1. Turn off all electric power to the appli-ance.

2. This appliance is equipped with an ig-nition device which automatically lightsthe burner. Do not try to light the burnerby hand.

3. Wait five (5) minutes to clear out anygas. Then smell for gas, including nearthe floor. If you smell gas, STOP! Fol-low "B" in the Safety Information locatedon the left side of this label. If you don'tsmell gas, go to next step.

4. Turn on all electric power to the appli-ance.

5. To light the burner, flip the ON/OFFswitch to the “ON” position. (The ON/OFF switch may include a wall switchif so equipped).

6. If the appliance will not operate, fol-low the instructions “To Turn Off Gasto Appliance” and call your service tech-nician or gas supplier.

LIGHTINGINSTRUCTIONS

(IPI)

TO TURN OFFGAS TO APPLIANCE

1. Turn off all electric power to the appli-ance if service is to be performed.

2. Flip ON/OFF switch to the “OFF” posi-tion.

FOR YOUR SAFETYREAD BEFORE LIGHTING

WARNING: If you do not follow these instructionsexactly, a fire or explosion may result causing prop-

erty damage, personal injury or loss of life.

A. This appliance is equipped withan intermittent pilot ignition (IPI)device which automatically lightsthe burner. Do not try to light theburner by hand.

B. BEFORE LIGHTING, smell allaround the appliance area forgas. Be sure to smell next to thefloor because some gas isheavier than air and will settle onthe floor.

WHAT TO DO IF YOU SMELL GAS• Do not try to light any appliance.

DO NOT CONNECT 110 VACTO THE CONTROL VALVE.Improper installation, adjustment,alteration, service or maintenancecan cause injury or property dam-age. Refer to the owner's informa-tion manual provided with this ap-pliance.This appliance needs fresh air forsafe operation and must be in-stalled so there are provisions foradequate combustion and ventila-tion air.If not installed, operated, and main-tained in accordance with themanufacturer's instructions, thisproduct could expose you to sub-stances in fuel or fuel combustionwhich are known to the State of Cali-fornia to cause cancer, birth de-fects, or other reproductive harm.Keep burner and control compart-ment clean. See installation andoperating instructions accompany-ing appliance.

CAUTION:Hot while in operation. Do nottouch. Keep children, clothing, fur-niture, gasoline and other liquidshaving flammable vapors away.

Do not operate the appliance withpanel(s) removed, cracked or bro-ken. Replacement of the panel(s)should be done by a licensed orqualified service person.

• Do not touch any electric switch;do not use any phone in your build-ing.

• Immediately call your gas supplierfrom a neighbor's phone. Followthe gas supplier's instructions.

• If you cannot reach your gas sup-plier, call the fire department.

C. Do not use this appliance if anypart has been under water. Imme-diately call a qualified service tech-nician to inspect the appliance andto replace any part of the controlsystem and any gas control whichhas been under water.

NOT FOR USEWITH SOLID FUEL

For use with natural gas and pro-pane. A conversion kit, as suppliedby the manufacturer, shall be usedto convert this appliance to the al-ternate fuel.

Also Certified for Installation ina Bedroom or a Bedsitting Room.

For assistance or additional informa-tion, consult a qualified installer, ser-vice agency or the gas supplier.

WARNING:

593-913C

GASVALVE

For additional information on operating your Hearth Technologies appliance, please refer to www.Fireplaces.com.

Page 35: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/05 35

C. After Appliance is Lit

D. Frequently Asked Questions

Initial Break-in Procedure

When you light the appliance, you may notice that it pro-duces heat which does have an associated odor or smell.If you feel this odor is excessive it may require the initialthree to four hour continuous burn on high followed by asecond burn up to 12 hours to fully drive off any odor frompaint and lubricants used in the manufacturing process.Condensation of the glass is normal.

NOTE: The appliance should be run three to four hourson the initial start-up. Turn it off and let it cool completely.Remove and clean the glass. Replace the glass and runthe appliance for an additional 12 hours. This will help tocure the products used in the paint and logs.

During this break-in period it is recommended that some win-dows in the house be opened for air circulation. This will helpavoid setting off smoke detectors, and help eliminate anyodors associated with the appliance’s initial burning.

Fire Risk.High Temperatures.

WARNING

Keep combustible household items away from appliance.Do NOT obstruct combustion and ventilation air.• Do NOT place combustible items on top of or in front

of appliance.• Keep furniture, draperies away from appliance.

Smoke and odors released during initial operation.• Open windows for air circulation.• Leave room during initial operation.• Smoke may set off smoke detectors.

Smoke and odors may be irritating to sensitiveindividuals.

CAUTION

• Prevent accidental appliance operation when notattended.

• Unplug or remove batteries from remote control ifabsent or if appliance will not be used for an extendedperiod of time.

• Property damage possible from elevated temperatures.

CAUTION

Fire Hazard.Keep combustible materials, gasolineand other flammable vapors and liquidsclear of appliance.

WARNING

• Do NOT store flammable materials in the appliance’svicinity.

• Do NOT use gasoline, lantern fuel, kerosene, charcoallighter fluid or similar liquids in this appliance.

• Combustible materials may ignite.

ISSUE SOLUTIONS

Condensation on the glass This is a result of gas combustion and temperature variations. As the appliancewarms, this condensation will disappear.

Blue flames This is a result of normal operation and the flames will begin to yellow as theappliance is allowed to burn for 20 to 40 minutes.

Odor from applianceWhen first operated, this appliance may release an odor for the first several hours.This is caused by the curing of the paint and the burning off of any oils remainingfrom manufacturing. Odor may also be released from finishing materials andadhesives used around the appliance.

Film on the glassThis is a normal result of the curing process of the paint and logs. Glass should becleaned within 3 to 4 hours of initial burning to remove deposits left by oils from themanufacturing process. A non-abrasive cleaner such as gas fireplace glass cleanermay be necessary. See your dealer.

Metallic noiseNoise is caused by metal expanding and contracting as it heats up and cools down,similar to the sound produced by a furnace or heating duct. This noise does not affectthe operation or longevity of the appliance.

Is it normal to see the pilot flameburn continually?

In an Intellifire ignition system it is normal to see the pilot flame, but it should turn offwhen ON/OFF is turned off. In a standing pilot system the pilot will always stay on.

Page 36: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/0536

A. Intellifire Ignition System

Symptom Possible Causes Corrective Actions1. Theignitor/modulemakes noise, but nospark.

a. Incorrect wiring. Verify "S" wire (white) for sensor and "I" wire (orange) for ignitor areconnected to correct terminals on module and pilot assembly. Reversed wiresat the module may cause system to make sparking noise, but spark may notbe present at pilot hood.

b. Looseconnections orelectrical shorts inthe wiring.

Verify no loose connections or electrical shorts in wiring from module to pilotassembly. Rod closest to pilot hood should be ignitor. Verify connectionsunderneath pilot assembly are tight; also verify connections are not groundingout to metal chassis, pilot burner, pilot enclosure, mesh screen if present, orany other metal object.

c. Ignitor gap is toolarge.

Verify gap of igniter to pilot hood. The gap should be approximately .17 inchor 1/8 inch.

d. Faulty module. Turn ON/OFF rocker switch or wall switch to OFF position. Remove ignitorwire "I" from module. Place ON/OFF Rocker switch or wall switch in ONposition. Hold ground wire about 3/16 inch away from "I" terminal on module.If there is no spark at "I" terminal module must be replaced. If there is a sparkat "I" terminal, module is fine. Inspect pilot assembly for shorted sparker wireor cracked insulator around electrode.

2. Pilot won't light,there is no noise orspark.

a. Transformerinstalled correctly.

Verify that transformer is installed and plugged into module. Check voltage oftransformer under load at spade connection on module with ON/OFF switchin ON position. Acceptable readings of a good transformer are between 3.2and 2.8 volts AC.

b. A shorted orloose connection inwiring configurationor wiring harness.

Remove and reinstall the wiring harness that plugs into module. Verify there isa tight fit. Verify pilot assembly wiring to module. Remove and verify continuityof each wire in wiring harness.

c. Improper wallswitch wiring.

Verify that 110/VAC power is "ON" to junction box.

d. Module notgrounded.

Verify black ground wire from module wire harness is grounded to metalchassis of appliance.

e. Faulty module. Turn ON/OFF rocker switch or wall switch to OFF position. Remove ignitorwire "I" from module. Place ON/OFF Rocker switch or wall switch in ONposition. Hold ground wire about 3/16 inch away from "I" terminal on module.If there is no spark at "I" terminal module must be replaced. If there is a sparkat "I" terminal, module is fine. Inspect pilot assembly for shorted sparker wireor cracked insulator around electrode.

3. Pilot lights butcontinues to spark,and main burner willnot ignite. (If thepilot continues tospark after the pilotflame has been lit,flame rectificationhas not occurred.)

a. A shorted orloose connection insensor rod.

Verify all connections to wiring diagram in manual. Verify connectionsunderneath pilot assembly are tight. Verify connections are not grounding outto metal chassis, pilot burner, pilot enclosure or screen if present, or any othermetal object.

b. Poor flamerectification orcontaminatedsensor rod.

Verify that flame is engulfing sensor rod. If the pilot assembly does not have aground strap, consider installing one to increase flame rectification. Verifycorrect pilot orifice is installed and inlet gas specifications. Flame carriesrectification current, not the gas. If flame lifts from pilot hood, the circuit isbroken. A wrong orifice or too high an inlet pressure can cause pilot flame tolift. The sensor rod may be contaminated. Clean sensor rod with emery cloth.

c. Module is notgrounded.

Verify that module is securely grounded to metal chassis of appliance. Verifythat wire harness is firmly connected to module.

Troubleshooting14With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you doexperience a problem, this troubleshooting guide will assist a qualified service person in the diagnosis of a problem and thecorrective action to be taken. This troubleshooting guide can only be used by a qualified service technician.

Page 37: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/05 37

Intellifire Ignition System - (continued)

Symptom Possible Causes Corrective Actions3. (Continued) d. Damaged pilot

assembly or dirtysensor rod.

Verify that ceramic insulator around the sensor rod is not cracked, damaged,or loose. Verify connection from sensor rod to white sensor wire. Cleansensor rod with emery cloth to remove any contaminants that may haveaccumulated on sensor rod. Verify continuity with a multimeter with ohms setat lowest range.

e. Faulty module. Turn ON/OFF rocker switch or wall switch to OFF position. Remove ignitorwire "I" from module. Place ON/OFF Rocker switch or wall switch in ONposition. Hold ground wire about 3/16 inch away from "I" terminal on module.If there is no spark at "I" terminal module must be replaced. If there is a sparkat "I" terminal, module is fine. Inspect pilot assembly for shorted sparker wireor cracked insulator around electrode.

4. Pilot sparks, butPilot will not light.

a. Correct gassupply.

Verify that incoming gas line ball valve is "open". Verify that inlet pressurereading is within acceptable limits, inlet pressure must not exceed 14 in. W.C.

b. Ignitor gap is toolarge.

Verify that spark gap from ignitor to pilot hood is .17 in. or 1/8 in.

c. Module is notgrounded.

Verify module is securely grounded to metal chassis of appliance.

d. Module voltageoutput / Valve/Pilotsolenoid ohmsreadings.

Verify battery voltage is at least 2.7 volts. Replace batteries if voltage isbelow 2.7.

Page 38: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/0538

Maintaining and Servicing Appliance15Although the frequency of appliance servicing and maintenance will depend on use and the type of installation, a qualified servicetechnician should perform an appliance checkup at the beginning of each heating season.

WARNINGAnnual inspection by qualified technician recommended.

Check:• Condition of doors, surrounds and fronts.• Condition of glass, glass assembly and glass seal.• Obstructions of combustion and ventilation air.• Condition of logs.• Condition of firebox.• Burner ignition and operation.• Burner air shutter adjustment• Gas connections and fittings.• Obstructions of termination cap.Clean:• Glass• Air passageways, grilles,

control compartment• Burner, burner portsRisk of:• Fire• Delayed ignition or explosion• Exposure to combustion fumes• Odors

Handle glass assembly with care.

NOTE: Clean glass after initial 3-4 hoursoperation. Longer operation withoutcleaning glass may cause a permanentwhite film on glass.

CAUTION

When cleaning glass door:• Avoid striking, scratching or slamming glass.• Do NOT use abrasive cleaners.• Use a hard water deposit glass cleaner on white film.• Do NOT clean glass when hot.• Turn off appliance after 3-4 hours of operation and

ALLOW TO COOL.• Remove and clean glass assembly.• Replace glass assembly and operate appliance for

additional 12 hours.Refer to maintenance instructions.

Risk of injury or property damage.Before servicing:• Turn off gas.• Turn off electricity to appliance.• Disable remote control, if one is present.• Ensure appliance is completely cooled.After servicing:• Replace any screen or barrier that was removed.• Reseal and reinstall any venting removed for servicing.

WARNING

Inspect external vent cap regularly.• Ensure no debris blocks cap.

WARNING

• Combustible materials blocking cap may ignite.• Restricted air flow affects burner operation.

Page 39: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/05 39

A. Replacing Light Bulbs1. Remove appliance front, appliance glass and logs.2. Remove refractory retainer by unscrewing two screws

at roof of firebox and remove refractory (see Figure 15.1).3. Remove false basepan by unscrewing two screws (see

Figure 15.2).4. Detach pilot bracket from burner by unscrewing two

screws (see Figure 15.3).5. Remove burner assembly by unscrewing two screws

(see Figure 15.4).6. Remove amber film. Pry tab with screwdriver if necessary

(see Figure 15.5).7. Gently remove bulb from socket (see Figure 15.6).8. Place new bulb firmly into socket (see Figure 15.7).9. Replace all parts in reverse order. Consult log placement

instructions for proper installation.Figure 15.1

Figure 15.2

Figure 15.6

Figure 15.5Figure 15.4

Figure 15.3

Figure 15.7

Page 40: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/0540

Inspect Maintenance TasksDoors, Surroundsand Fronts

1. Assess condition of screen and replace as necessary. Recommend addition of screenif one is not present.2. Inspect for scratches, dents or other damage and repair as necessary.

3. Verify no obstructions to airflow through the louvers.

4. Verify maintenance of proper clearance to combustible household objects.Gasket Seal, GlassAssembly and Glass 1. Inspect gasket seal and its condition.

2. Inspect glass panels for scratches and nicks that can lead to breakage when exposed toheat.3. Confirm there is no damage to glass or glass frame. Replace as necessary.4. Verify that latches engage properly, clip studs are not stripped, and glass attachmentcomponents are intact and operating properly. Replace as necessary.5. Clean glass. Replace glass assembly if severely coated with silicate deposits that cannotbe removed.

Valve Compartmentand Firebox Top

1. Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning theseareas. Screw tips that have penetrated the sheet metal are sharp and should be avoided.2. Remove any foreign objects.

3. Verify unobstructed air circulation.Logs 1. Inspect for broken, damaged, or missing logs. Replace as necessary.

2. Verify correct log placement and no flame impingement causing sooting. Correct asnecessary.

Firebox 1. Inspect for paint condition, warpage, corrosion or perforation. Sand and repaint asnecessary.

2. Replace appliance if firebox has been perforated.Burner Ignition andOperation 1. Verify burner is properly secured and aligned with pilot or igniter.

2. Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner ifnecessary.3. Replace ember materials with new dime-size and shape pieces. Do not block ports orobstruct lighting paths.

4. Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay.

5. Inspect for lifting or other flame problems.

6. Verify air shutter is clear of dust and debris.

7. Inspect orifice for soot, dirt or corrosion.

8. Verify manifold and inlet pressures. Adjust regulator as required.

9. Inspect pilot flame strength. Clean or replace orifice as necessary.10. Inspect thermocouple/thermopile or IPI sensor rod for soot, corrosion and deterioration.Clean with emery cloth or replace as required.11. Verify millivolt output. Replace as necessary.

Venting 1. Inspect venting for blockage or obstruction such as bird nests, leaves, etc.2. Confirm that termination cap remains clear and unobstructed by plants, etc.3. Verify that termination cap clearance to subsequent construction (building additions, decks,fences or sheds) has been maintained.4. Inspect for corrosion or separation.5. Verify weather stripping, sealing and flashing remains intact.6. Inspect draft shield to verify it is not bent, damaged or missing.

Remote controls 1. Verify operation of remote.

2. Replace batteries in remote transmitters and battery-powered receivers.

3. Verify batteries have been removed from battery back-up IPI systems to prevent prematurebattery failure or leaking.

Page 41: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/05 41

Reference Materials16

Location Inches Millimeter Location Inches MillimeterA 29-1/8 740 J 11-1/2 292B 25-9/32 643 K 11-1/2 292C 37-3/16 945 L 11 279D 29-3/16 742 M 5-9/16 142E 4-1/8 105 N 6-5/8 168

F 2-3/16 56 O 37 940

G 4-1/2 115 P 3-3/4 96

H 32-3/4 832 Q 2-1/4 57I 23-1/16 586

Appliance Dimensions Table

A. Appliance Dimension DiagramDimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 3.

Figure 16. 1 Appliance Dimensions

A

B

CD

EF

G

H

IJ

KL

MØN

O

P

Q

GAS LINEACCESS

ELECTRICALACCESS

Page 42: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/0542

B. Vent Components Diagrams

Figure 16. 1 DVP vent components

SL Series Components

COOL-ADDCap Shield

11-5/8 in.

5-3/4 in.

7-1/8 in.12-1/8 in.

DRC-RADIUSCap Shield

13-7/8 in. 9-1/2 in.

14 in.

Page 43: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/05 43

B. Vent Components Diagrams (continued)

Figure 16.3

SL D-Series Vent Components

Pipe Length/InchesSL-06D 5-3/4SL-09D 8-3/4SL-12D 11-3/4SL-12/17D 11-3/4 to 16-3/4SL-17/24D 16-3/4 to 23-3/4SL-24D 23-3/4SL-36D 35-3/4SL-48D 47-3/4SL-FLEX-2 24SL-FLEX-3 36SL-FLEX-5 60SL-FLEX-10 120

9 1/4 in.

6 5/8 in.

6 ½ in. 6 3/8 in.

6 ½ in.9 5/8 in.

9 5/8 in.

6 5/8 in.

6 3/8 in.

SLK-991DAVERTICAL

TERMINATIONCAP

SLK-SNKDSNORKEL

TERMINATIONCAP*

PVK-80POWER VENT

*There MUST be a 25% reductionin total H when using the snorkel

cap except when using thesimple up and out installation.

(For use on Intellifireappliances only)

WALL BRACKET(SL-SERIES)

HORIZONTAL PIPESUPPORT

(SL-SERIES)

EFFECTIVEHEIGHT/LENGTH

SL-PIPE

SL-45D

SL-90D

SLK-01TRDSLK-01TRF

HORIZONTALTERMINATION CAP

SLK-00TRD

Must use 2077-150Flue Restrictor

(Included with appliance).

Page 44: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/0544

C. Service Parts List

* Part number list on following page.

* La liste des numéros de pièce se trouve à la page suivante.

6 Log Set Assembly

7

119

8

10

(NG, LP) Exploded Parts Diagram(GN, PL) Vue éclatée des pièces

Soho24Beginning Manufacturing Date: 4-05Ending Manufacturing Date: ______

5

4

2

1 3

12

Page 45: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/05 45

ITEM /PIÈCE COMMON PARTS / PIÉCES COMMUNES SERIAL #

/ N° DE SÉRIEPART NUMBER/ N° DE PIÈCE

1 Glass Door Assembly / Porte en verre GLA-Soho24

2 Burner NG, LP / Brûleur GN, PL 2077-007

3 False basepan / Basepan faux 2077-100

4 Wall Refractory Kit (Firebrick, gray mortar lines) Brick-Soho24

5 Junction Box / Boîtier de raccordement 4021-013

6 Log Set Assembly / Jeu de Bûches LOGS-SOHO24

7 Log 1 / Bûche 1 SRV2077-700

8 Log 2 / Bûche 2 SRV2077-701

9 Ash Piece - Left / Le Morceau de cendre - Part SRV2077-702

10 Ash Piece - Center / Le Morceau de cendre - Centre SRV2077-703

11 Ash Piece - Right / Le Morceau de cendre - la Droite SRV2077-704

12 Non-combustible Board / Conseil incombustible 2077-148

Flue Restrictor / Restricteur de conduite de cheminée 2077-150

Vent Gasket / Joint de Conduit 530-408

Mineral Wool Embers / Les Braises minérales de Laine 050-721

Mystic Embers / Braises mystiques Mystic-Embers

Surround / Entourez 2077-112

Glass Latch Support Assembly / L'Assemblée de Soutien de Loquet de verre 386-122A

3 Function Circuit Board / 3 Conseil de Circuit de Fonction 2083-030

12V Adaptor / 12V Bouchon d'adapteur 2083-022

Solenoid / Solénoïde HTI-17-006

Wire, Wall Switch / Le fil, le Commutateur de Mur 2083-031

Wall Switch & Cover Plate / Cache de l'interrupteur mural 4041-128

ACCESSORIES / ACCESSOIRES

Battery Remote Control / Télécommande de pile RC-BATT-HNG

Battery Remote Control with Thermostate and Timer / La Télécommande depile avec Thermostate et le Minuteur SMART-BATT-HNG

Conversion Kit NG / Module de conversion GN NGK-Soho24

Conversion Kit LP / Module de conversion PL LPK-Soho24

C. Service Parts List / Liste des pièces de rechange Soho24

See following page for additional IPI service part numbers.

IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on your dealers VIP site. When ordering,supply serial and model numbers to ensure correct service parts. / IMPORTANT : L'information fournie dans cette brochure n'estvalide que pendant une courte période. Les sites VIP des distributeurs disposent des renseignements les plus récents. Lors d'unecommande, veuillez fournir les numéros de série et de modèles pour un remplacement adéquat des pièces.

Page 46: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/0546

(NG, LP) Exploded Parts Diagram(GN, PL) Vue éclatée des pièces

Service Parts Soho24

ITEM /PIÈCE DESCRIPTION SERIAL #

/ N° DE SÉRIEPART NUMBER/ N° DE PIÈCE

1 Valve Bracket / Parenthèse de Valve 2077-1222 NG Flex Ball Valve Assembly / GN Fléchir l'Assemblée de Soupape de Balle 2083-0622 LP Flex Ball Valve Assembly / PL Fléchir l'Assemblée de Soupape de Balle 2083-0633 Burner Neck Gasket / Joint de Cou de Brûleur 438-4074 Valve NG / Valve GN 750-5004 Valve LP / Valve PL 593-5015 Burner Orifice NG (#51C) / Orifice de brûleur NG (#51C) 582-8515 Burner Orifice LP (#60C) / Orifice de brûleur PL (#60C) 582-8606 Module / Module 593-5927 Wire Assembly / Module de fil 593-590A8 18" Flexible Gas Connector / Tuyau à gaz flexible 530-302A9 Valve Plate Gasket / Joint de Plat de Valve 2077-13810 Pilot Bracket / Parenthèse Pilote 2077-16211 Pilot Assembly NG / Module de veilleuse GN 2090-01211 Pilot Assembly LP / Module de veilleuse PL 2090-01312 3 Volt Transformer / 3 Transformateur de Volt 593-593A13 Light Bulb / Ampoule légère 2057-13314 Light Harness / Harnais léger 2077-06115 Kapton Film / Kapton Film 2093-11916 Burner Assembly NG / Brûleur GN 2077-00717 Light Bracket / Crochet léger 2077-151

Beginning Manufacturing Date: 4-05Ending Manufacturing Date: ______

Intermittent Pilot IgnitionValve Assembly

12

3

4

78

9

10

11

12

13 14

15

6

5

16

17

Page 47: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/05 47

© 2005 Hearth & Home Technologies Inc.

LIMITED LIFETIME WARRANTYHEAT & GLO GAS APPLIANCE PRODUCTS

BASIC ONE-YEAR WARRANTY. HEAT & GLO, a brand of HEARTH & HOME TECHNOLOGIES INC., located at 20802 KensingtonBoulevard, Lakeville, MN 55044, (“HEAT & GLO”) warrants to the original owner that your new HEAT & GLO Gas Appliance (the “Product”)will be free from defects in materials and workmanship for a period of one year from the date of installation. During the first year, HEAT & GLOwill replace or repair, at its discretion, any defective components at its sole cost and expense, including payment of all reasonable labor costsincurred in replacing or repairing such components. This basic warranty is subject to the conditions, exclusions and limitations described below.EXTENDED LIFETIME COVERAGE. HEAT & GLO warrants that the firebox, heat exchanger, log(s), and burner will not be defective inmaterial or workmanship during the period the Product is owned by the original owner, subject to the following conditions, exclusions andlimitations described below.CONDITIONS, EXCLUSIONS AND LIMITATIONS:1. This warranty applies to the original owner only and is nontransferable.2. This warranty applies only to Products installed in the United States of America or Canada.3. This warranty is limited to the replacement or repair of defective components or workmanship and HEAT & GLO may fully discharge all

obligations under this warranty by repairing or replacing, at its discretion, the defective components. The maximum amount recoverableunder this warranty is limited to the purchase price of the Product and, if HEAT & GLO is unable to provide replacement or repair in anexpedient and cost-effective manner, HEAT & GLO may discharge all obligations under this warranty by refunding the purchase price ofthe Product. IN NO EVENT SHALL HEAT & GLO BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES CAUSED BYDEFECTS IN THE PRODUCT.

4. Any labor and related repair charges relating to the costs and expenses of replacing or repairing defective components under the LimitedLifetime Warranty are not covered by this warranty, except as provided for under the Basic One-Year Warranty.

5. Components and parts made by other manufacturers, whether sold with the Product or added thereafter, are NOT covered by thiswarranty unless expressly authorized and approved by HEAT & GLO in writing.

6. Any damages caused by environmental conditions, inadequate ventilation or drafting caused by tight sealing construction of the structure,air handling devices such as exhaust fans or forced air furnaces, or other such causes are not covered by this warranty.

7. This warranty will be void if:a) The Product is not installed, operated and maintained in compliance with local building codes and with the instructions in the Installer’s

Guide, Owner’s Guide and Listing Agent Identification Label furnished with the Product.b) Any parts or components made by other manufacturers are added or used in the Product, unless expressly authorized and

approved by HEAT & GLO in writing.c) Any service work is performed on the Product by anyone other than an authorized HEAT & GLO representative.d) The Product is damaged due to shipping, improper handling, accident, abuse or misuse.e) Fuels other than those specified in the Installer’s Guide and Owner’s Guide are used.f ) Modification was made to the Product which was not expressly authorized and approved by HEAT & GLO in writing.

EXCEPT TO THE EXTENT PROVIDED BY LAW, HEAT & GLO MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTYSPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO THE DURATION OF THE WARRANTY SPEC-IFIED ABOVE.Some states do not allow limitations on how long an implied warranty lasts, or do not allow exclusion or limitation of incidental or consequentialdamages, so those limitations may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which varyfrom State to State.If warranty service is needed you should contact your installing dealer and if the installing dealer is unable to provide necessary parts orcomponents, contact the nearest authorized HEAT & GLO dealer or supplier.NOTES TO CUSTOMER:1. In order to insure proper installation, operation and maintenance HEAT & GLO strongly recommends annual

servicing by an authorized HEAT & GLO dealer.2. Please complete this information and retain this warranty in a safe place for future reference: Installation Date:______

Model #:_________________ Serial #:______________ Installing Contractor:_________________________3. HEAT & GLO reserves the right to make changes at any time, without notice, in design, material, specifications

and prices of the Product. HEAT & GLO also reserves the right to discontinue styles and products.

060-981C 1/05

D. Limited Lifetime Warranty

Page 48: Owner’s Manual - WITTUS manual.pdf · 2019-05-10 · Owner’s Manual Installation and Operation Model: Soho24 • Do not store or use gasoline or other flamma-ble vapors and liquids

Heat & Glo • Soho24 • 2077-900 Rev. F • 8/0548

Heat & Glo, a brand of Hearth & Home Technologies Inc.20802 Kensington Boulevard, Lakeville, MN 55044

www.fireplaces.com

E. Contact Information

Please contact your Heat & Glo dealer with any questions or concerns.For the number of your nearest Heat & Glo dealer,

please call 1-888-427-3973.

- NOTES -

_______________________________________________________________________________

_______________________________________________________________________________

_______________________________________________________________________________

_______________________________________________________________________________

_______________________________________________________________________________

_______________________________________________________________________________

_______________________________________________________________________________

_______________________________________________________________________________

_______________________________________________________________________________

Printed in U.S.A. - Copyright 2005

DO NOT DISCARD THIS MANUAL

CAUTION

• • •

This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471, 5328356,5341794, 5347983, 5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099, 6048195, 6053165, 6145502, 6170481,6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, D320652, D445174, D462436; (Canada) 1297749,2195264, 2225408; or other U.S. and foreign patents pending.

Important operatingand maintenanceinstructions included.

Read, understand and followthese instructions for safeinstallation and operation.

Leave this manual withparty responsible for useand operation.