MD 235716 001 2017 02 03 MD 235716 001 2017 02 03 MD 235716 001 2017 02 03 Mechanical DO AO DI AI LPI LPI AI LPI LPI AI HX-1 HX-2 LPI SEE DETAIL SEPARATOR W/ AIRVENT. COALESCING AIR SEE DETAIL TYP. HEAT EXCHANGER. DO AO DI X" L P C ST ST 1. NOTES: HWHR HWHS DETAILS AND SPECIFICATIONS, FOR ADDITIONAL REQUIREMENTS. REFER TO CONSTRUCTION DOCUMENTS, INCLUDING PLANS, ELEVATIONS, ALL REQUIRED COMPONENTS AND ACCESSORIES ARE NOT IDENTIFIED. X"HWHR X"HWHR X"HWHS X" L PS X"LPS X" L PS X"HWHR X"HWHS X"HWHS X"HWHR X" L PS X" L P C X"LPC X"HWHR SEE DETAIL EXPANSION TANK. X"CW SEE DETAIL CW MAKE UP. SEE DETAIL (TYP.) HWH PUMP. HWHP-1 CSR-1 CSR-2 HWHP-2 TRANSMITTER. SEE DETAIL DIFFERENTIAL PRESSURE ROOM ____ LPI LPI AI (TYP.) REDUCER ECCENTRIC TO DRIP TRAP (TYP.) CONDENSATE DRAINAGE SLOPE PIPE TO ALLOW NO SCALE SEE DETAIL EQUIPMENT STEAM TRAP (TYP.). 07.08.15 STATION. SEE DETAIL STEAM CONTROL VALVE AI AO M XDCR-2 AO M XDCR-1 CV-2 CV-1 AO M XDCR-3 CV-4 AO M XDCR-4 CV-3 N.O. 8-13# N.O. 8-13# VALVE CONTROL SMALLER VALVE LARGER CONTROL N.O. 8-13# VALVE LARGER CONTROL VALVE SMALLER CONTROL N.O. 8-13# SCHEDULE MARK A B C D SIZE (IN) C"LPS C" LPS D" LPS B" LPS B" LPS A" LPS C" LPS A" LPS B" LPS C" LPS D" LPS ET-1 EMFM-1 B" LPS EXCHANGER HX-2 CONNECT TO HEAT DPT-1 TSW-1 TSW-2 LPI T LPI AI TSW-4 VFD-1 VFD-2 TSW-3 EXCHANGER HX-1 CONNECT TO HEAT NO SCALE TEMP (DEG. F) HWH SUPPLY RESET SCHEDULE (DEG. F) OA TEMP >65 65 55 0 1 1 Steam to Water Heat Exchangers P & ID CRITICAL HEAT EXCHANGER SYSTEM U OF M DESIGN SUPERVISOR APPROVED BY REPRESENTING DRAWN BY REVIEWED BY DESIGNED BY MARK ISSUED FOR/REVISIONS DATE Standardization Committee University Of Michigan Ann Arbor , MI U OF M PROJECT NO. BLDG NO. ICHIGAN M NIVERSITY OF U ARCHITECTURE, ENGINEERING AND CONSTRUCTION Ann Arbor, MI 48109-1002 326 East Hoover, Mail Stop E Phone: 734-763-3020 Fax: 734-763-3238 ICHIGAN M NIVERSITY OF U ARCHITECTURE, ENGINEERING AND CONSTRUCTION Ann Arbor, MI 48109-1002 326 East Hoover, Mail Stop B Phone: 734-764-3414 Fax: 734-936-3334 ARCHITECTURE & ENGINEERING DESIGN MANAGER Converter Heat Exchanger . . Steam to Water 07.08.15 SHEET FILE NO. SHEET NO. OF 1 1 Heat Exchangers Mechanical Steam to Water SHEET TITLE P & ID - Critical DESCRIPTION E/P TRANSDUCER ITEM NO. DIFF. PRESSURE TRANSMITTER DPT CV XDCR TSW TEMPERATURE SENSOR, WATER CONTROLS EQUIPMENT LIST CONTROL VALVE * * EMFM SENSOR ASSEMBLIES FOR BTU MEASUREMENT. TSW1 & TSW4 ARE HIGH PRECISION MATCHED TEMPERATURE ELECTROMAGNETIC FLOW METER CSR LPI CURRENT SENSING RELAY LOOP POWERED INDICATOR N.C. CRITICAL STEAM TO WATER HEAT EXCHANGER P & ID CRITICAL HEAT EXCHANGER STEAM CONTROL STATION DETAIL PUMP TOTAL RUN TIME, EACH PUMP D. TSW-1, 2, 3, 4, 30 MINUTE READING C. HWH GPM, 30 MINUTE READING (EMFM-1) B. BTU/HR, 30 MINUTE READING (EMFM-1, TSW-1, TSW-4) A. BAS TREND LOGGING: 11. DPT-1 MORE THAN 5 PSI ABOVE SETPOINT B. PUMP STATUS DOES NOT MATCH DDC COMMAND (AS DETECTED BY CSR) A. ADDITIONAL BAS DDC ALARMS (AFTER AN APPROPRIATE TIME DELAY) 10. ROTATED, DP STILL NOT AT SETPOINT”. SETPOINT IS NOT ACHIEVED, THE DDC SHALL GENERATE AN ALARM MESSAGE AT BAS “HX OF CRITICAL HX PROBLEM.” AFTER THE HX ROTATION AND A TIME DELAY IF THE DPT-1 SHALL STATE “ROTATING TO BACK-UP HX DUE TO PRESSURE PROBLEM. INVESTIGATE CAUSE ROTATE HEAT EXCHANGER OPERATION. DDC SHALL ALSO ALARM AT BAS. ALARM MESSAGE IF DPT-1 FALLS MORE THAN 2 PSI BELOW SETPOINT AFTER A TIME DELAY, DDC SHALL D. SETPOINT IS TO BE RESET IN SOME WAY.) OPENING. DESIGNER TO EXPAND UPON THIS PART OF THE SEQUENCE IF THE DPT-1 (DPT-1 SETPOINT CHANGES TO MAINTAIN WORST CASE TERMINAL VALVE AT 90% OF FULL C. BALANCE. FINAL SETPOINT SHALL BE DETERMINED WITH THE WATER BALANCER DURING TEST AND SETPOINT AT DPT-1. THE INITIAL SETPOINT SHALL BE <FILL IN PSI> PSI. THE PRESSURE DDC SHALL MODULATE THE PUMP VFD AS REQUIRED TO MEET THE DIFFERENTIAL B. THE MINIMUM PUMP OPERATING SPEED (PROGRAMMED INTO THE VFD) SHALL BE 12HZ. A. PUMP CONTROL 9. TRANSMITTER EXCEEDS 220°F, DDC SHALL ALARM AT BAS (NO TIME DELAY). IF THE TEMPERATURE AT THE OPERATING HX’S RESPECTIVE LEAVING TEMPERATURE D. SETPOINT”. GENERATE AN ALARM MESSAGE AT BAS “HX ROTATED, TEMPERATURE STILL NOT AT DELAY IF THE WATER TEMPERATURE SETPOINT IS NOT ACHIEVED, THE DDC SHALL INVESTIGATE CAUSE OF CRITICAL HX PROBLEM.” AFTER THE HX ROTATION AND A TIME MESSAGE SHALL STATE “ROTATING TO BACK-UP HX DUE TO TEMPERATURE PROBLEM. SHALL ROTATE HEAT EXCHANGER OPERATION. DDC SHALL ALSO ALARM AT BAS. ALARM IF THE SETPOINT VARIES MORE THAN ±10°F FROM SETPOINT, AFTER TIME DELAY, DDC C. CLOSED THE LARGEST CONTROL VALVE. VALVE. UPON A DECREASE IN LOAD, THE OPPOSITE SHALL OCCUR, FIRST MODULATING UPON CONTINUED INCREASE IN LOAD, MODULATE OPEN THE NEXT LARGER CONTROL UPON AN INCREASE IN LOAD, FIRST MODULATE OPEN THE SMALLEST CONTROL VALVE. B. CHANGES BASED ON THE INDICATED RESET SCHEDULE. RESPECTIVE LEAVING TEMPERATURE TRANSMITTER TSW-2 OR TSW-3. THE SETPOINT OPERATING HEAT EXCHANGER TO PRODUCE THE REQUIRED SETPOINT AT THE HX’S THE DDC SHALL SEQUENTIALLY MODULATE THE STEAM CONTROL VALVES OF THE A. STEAM VALVE CONTROL 8. OPERATION. ±10°F OF SETPOINT DDC SHALL ALARM AND SWITCH BACK TO LEAD HEAT EXCHANGER THE LEAVING WATER TEMPERATURE AT THE LAG HX TRANSMITTER IS NOT WITHIN AFTER THE 5 MINUTE TIME DELAY (ADJ), IF DPT-1 IS NOT WITHIN 2PSI OF SETPOINT OR C. VALVES. 5 MINUTES LATER, LEAD PUMP SHALL STOP. TEMPERATURE CONTROL TO STABILIZE, DDC SHALL CLOSE THE LEAD HX’S STEAM AFTER A 5 MINUTE TIME DELAY (ADJ) TO ALLOW THE LAG HEAT EXCHANGER HX'S RESPECTIVE DISCHARGE TEMPERATURE TRANSMITTER (TSW-2 OR TSW-3). VALVES TO MAINTAIN THE CURRENT HWH SETPOINT BY CONTROLLING TO THE LAG MAINTAIN THE DPT-1 SETPOINT. THE DDC SHALL CONTROL THE LAG HX STEAM LEAD PUMP’S SPEED AND THEN THE SPEED OF BOTH PUMPS WILL BE CONTROLLED TO LAG PUMP WILL RAMP UP GRADUALLY (AS SET IN THE VFD) UNTIL IT MATCHES THE TO ROTATE OPERATION, DDC SHALL FIRST START THE LAG PUMP. THE SPEED OF THE B. CONDITION DESCRIBED IN OTHER SEQUENCE PARAGRAPHS. EXCHANGER ROTATION SHALL ALSO OCCUR WHEN INITIATED BY AN OPERATING ROTATED WEEKLY IN OR OUT OF SERVICE BY THE DDC TO EQUALIZE RUN TIME. HEAT EACH HEAT EXCHANGER, STEAM CONTROL VALVE STATION, AND PUMP SHALL BE A. 7.ROTATING HEAT EXCHANGER OPERATION DETAILED SEQUENCE PRESSURE OR TEMPERATURE SETPOINT CAN’T BE MAINTAINED. THE DDC SHALL ROTATE TO THE OTHER HEAT EXCHANGER/PUMP SET IF THE DIFFERENTIAL 6. BE MODULATED TO ACHIEVE DPT-1 SETPOINT. LEAVING TEMPERATURE SENSOR. THE SPEED OF THE ASSOCIATED LEAD PUMP SHALL EXCHANGER TO ACHIEVE THE SUPPLY WATER SETPOINT AT THE HEAT EXCHANGER’S THE DDC SHALL SEQUENTIALLY CONTROL THE STEAM VALVES OF THE LEAD HEAT 5. THE SYSTEM SHALL OPERATE CONTINUOUSLY. 4. THE MANUAL VALVE IN THE COMMON PUMP CROSS-OVER HEADER SHALL BE CLOSED. 3. ISOLATION VALVES OPEN. BOTH PUMPS AND BOTH HEAT EXCHANGERS SHALL HAVE THEIR MANUAL 2. AND HEAT EXCHANGER ARE IDLE. ONE PUMP AND ONE HEAT EXCHANGER WILL OPERATE WHILE THE OTHER PUMP 1. SUMMARY SEQUENCE OF OPERATION: INCLUDE IN SEQUENCE IF REQUIRED.> MINIMUM <FILL IN GPM> HWH FLOW IS ATTAINED BY <BYPASS? THREE-WAY VALVES? OUT OF SERVICE WHILE MEETING THE PEAK DIVERSIFIED HWH LOAD. ONE HEAT EXCHANGER, ONE STEAM CONTROL VALVE STATION, OR ONE PUMP CAN BE HANDLE APPROXIMATELY <FILL IN PERCENT> OF THE PEAK DIVERSIFIED HWH LOAD. EACH HEAT EXCHANGER, STEAM CONTROL VALVE STATION, AND PUMP ARE SIZED TO DESIGN INTENT: MD 235716 001 MD 235716 001.dgn SEE DETAIL DRIP TRAP. CONDENSATE LOW PRESSURE (TYP.) ISOLATION VALVE SEE DETAIL DRIP TRAP. STEAM A" LOW PRESSURE (NOTE 1) STEAM SEPARATOR (NOTE 1) SEPARATOR STEAM (NOTE 2) STRAINER NOTES: STEAM STRAINER INSTALLATION DETAIL. ORIENT BASKET PORTION OF STRAINER IN HORIZONTAL POSITION. SEE INCREASERS SEPARATOR WHEN REQUIRED. FLOW RATE, BUT NOT LESS THAN DIMENSION "A". PROVIDE ECCENTRIC EXCEED THAT OF AN EQUIVALENT LENGTH OF PIPE AT THE DESIGN STEAM PROVIDE SEPARATOR SIZE HAVING A PRESSURE DROP THAT DOES NOT LOCATE STEAM SEPARATOR AS CLOSE AS POSSIBLE TO CONTROL VALVES. 2. 1. A" LPS TOP VIEW SIDE VIEW STRAINER ELBOW DOWN STRAINER A" LPS ELBOW DOWN NO SCALE STRAINER INSTALLATION DETAIL BIB CAPPED HOSE VALVE WITH (DELETE FOR BID DOC'S) DESIGNER NOTES: COMPLETE ALL MISSING INFORMATION. 1. 2. DG 235716 AND MASTER SPECIFICATION MS 235716 FOR ADDITIONAL INFORMATION. REVIEW STEAM TO WATER HEAT EXCHANGER SYSTEM DESIGN GUIDELINE 3. REVISE DETAIL ACCORDINGLY. IN SOME CASES IN MAY MAKE SENSE TO USE ONE SEPARATOR PER CONTROL VALVE RAMIFICATIONS. ALSO REFER TO NOTE 1. ON STEAM CONTROL STATION DETAIL. REVIEW MANUFACTURES DATA ON STEAM SEPARATORS FOR PRESSURE DROP T T

Upload: others

Post on 17-Mar-2020

76 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: P & ID P & ID - Critical - HVAC/MD... · p & id critical heat exchanger system u of m design supervisor approved by representing drawn by designed by reviewed by strainer mark issued

MD 235716 001 2017 02 03

MD 235716 001 2017 02 03

MD 235716 001 2017 02 03

Mechanical

DOAO DI

AI

LPI

LPI

AI

LPI

LPI

AI

HX-1

HX-2

LPI

SEE DETAIL

SEPARATOR W/ AIRVENT.

COALESCING AIR

SEE DETAIL TYP.HEAT EXCHANGER.

DOAO DI

X"LP

C

ST

ST

1.

NOTES:

HWHR

HWHS

DETAILS AND SPECIFICATIONS, FOR ADDITIONAL REQUIREMENTS.

REFER TO CONSTRUCTION DOCUMENTS, INCLUDING PLANS, ELEVATIONS,

ALL REQUIRED COMPONENTS AND ACCESSORIES ARE NOT IDENTIFIED.

X"HWHR

X"HWHR

X"HWHS

X"LPS

X"LPS

X"LPS

X"HWHR

X"HWHS

X"HWHSX"HWHR

X"LPS

X"LP

C

X"LPC

X"HWHR

SEE DETAIL

EXPANSION TANK.

X"CW

SEE DETAIL

CW MAKE UP.

SEE DETAIL (TYP.)HWH PUMP.

HWHP-1

CSR-1

CSR-2

HWHP-2

TRANSMITTER. SEE DETAILDIFFERENTIAL PRESSUREROOM ____

LPI

LPI

AI

(TYP.)

REDUCER

ECCENTRIC

TO DRIP TRAP (TYP.)

CONDENSATE DRAINAGE

SLOPE PIPE TO ALLOW

NO SCALE

SEE DETAILEQUIPMENT STEAM TRAP (TYP.).

07.08.15

STATION. SEE DETAIL

STEAM CONTROL VALVE

AI

AO

M

XDCR-2

AO

M

XDCR-1

CV-2

CV-1

AO

M

XDCR-3

CV-4

AO

M

XDCR-4

CV-3

N.O.

8-13#

N.O.

8-13#

VALVE

CONTROL

SMALLER

VALVE

LARGER CONTROL

N.O.

8-13#

VALVE

LARGER CONTROL

VALVE

SMALLER CONTROLN.O.

8-13#

SCHEDULE

MARK

A

B

C

D

SIZE (IN)

C"LPS C" LPS

D" LPS

B" LPS

B" LPS

A" LPS

C" LPS

A" LPS

B" LPS

C" LPS

D" LPS

ET-1

EMFM-1

B" LPS

EXCHANGER HX-2

CONNECT TO HEAT

DPT-1

TSW-1

TSW-2

LPI

T

LPI

AI

TSW-4

VFD-1

VFD-2

TSW-3

EXCHANGER HX-1

CONNECT TO HEAT

NO SCALE

TEMP (DEG. F)

HWH SUPPLY

RESET SCHEDULE

(DEG. F)

OA TEMP

>65

65

55

0

1 1

Steam to Water

Heat Exchangers

P & ID

CRITICAL HEAT EXCHANGER SYSTEM

U OF M DESIGN SUPERVISOR

APPROVED BY

REPRESENTING

DRAWN BY

REVIEWED BYDESIGNED BY

MARK ISSUED FOR/REVISIONS DATE

Standardization Committee

University Of Michigan

Ann Arbor , MI

U OF M PROJECT NO. BLDG NO.

ICHIGANM NIVERSITY OFUARCHITECTURE, ENGINEERING AND CONSTRUCTION

Ann Arbor, MI 48109-1002

326 East Hoover, Mail Stop E

Phone: 734-763-3020

Fax: 734-763-3238

ICHIGANM NIVERSITY OFUARCHITECTURE, ENGINEERING AND CONSTRUCTION

Ann Arbor, MI 48109-1002

326 East Hoover, Mail Stop B

Phone: 734-764-3414

Fax: 734-936-3334

ARCHITECTURE & ENGINEERING

DESIGN MANAGER

Converter

Heat Exchanger

. .

Steam to Water

07.08.15

SHEET FILE NO.SHEET NO. OF 1 1

Heat Exchangers

Mechanical

Steam to Water

SHEET TITLE

P & ID - Critical

DESCRIPTION

E/P TRANSDUCER

ITEM NO.

DIFF. PRESSURE TRANSMITTERDPT

CV

XDCR

TSW TEMPERATURE SENSOR, WATER

CONTROLS EQUIPMENT LIST

CONTROL VALVE

*

*

EMFM

SENSOR ASSEMBLIES FOR BTU MEASUREMENT.

TSW1 & TSW4 ARE HIGH PRECISION MATCHED TEMPERATURE

ELECTROMAGNETIC FLOW METER

CSR

LPI

CURRENT SENSING RELAY

LOOP POWERED INDICATOR

N.C.

CRITICAL STEAM TO WATER HEAT EXCHANGER P & ID

CRITICAL HEAT EXCHANGER STEAM CONTROL STATION DETAIL

PUMP TOTAL RUN TIME, EACH PUMPD.

TSW-1, 2, 3, 4, 30 MINUTE READINGC.

HWH GPM, 30 MINUTE READING (EMFM-1)B.

BTU/HR, 30 MINUTE READING (EMFM-1, TSW-1, TSW-4)A.

BAS TREND LOGGING:11.

DPT-1 MORE THAN 5 PSI ABOVE SETPOINTB.

PUMP STATUS DOES NOT MATCH DDC COMMAND (AS DETECTED BY CSR)A.

ADDITIONAL BAS DDC ALARMS (AFTER AN APPROPRIATE TIME DELAY)10.

ROTATED, DP STILL NOT AT SETPOINT”. SETPOINT IS NOT ACHIEVED, THE DDC SHALL GENERATE AN ALARM MESSAGE AT BAS “HXOF CRITICAL HX PROBLEM.” AFTER THE HX ROTATION AND A TIME DELAY IF THE DPT-1SHALL STATE “ROTATING TO BACK-UP HX DUE TO PRESSURE PROBLEM. INVESTIGATE CAUSEROTATE HEAT EXCHANGER OPERATION. DDC SHALL ALSO ALARM AT BAS. ALARM MESSAGE

IF DPT-1 FALLS MORE THAN 2 PSI BELOW SETPOINT AFTER A TIME DELAY, DDC SHALLD.

SETPOINT IS TO BE RESET IN SOME WAY.)

OPENING. DESIGNER TO EXPAND UPON THIS PART OF THE SEQUENCE IF THE DPT-1

(DPT-1 SETPOINT CHANGES TO MAINTAIN WORST CASE TERMINAL VALVE AT 90% OF FULLC.

BALANCE.

FINAL SETPOINT SHALL BE DETERMINED WITH THE WATER BALANCER DURING TEST AND

SETPOINT AT DPT-1. THE INITIAL SETPOINT SHALL BE <FILL IN PSI> PSI. THEPRESSURE

DDC SHALL MODULATE THE PUMP VFD AS REQUIRED TO MEET THE DIFFERENTIALB.

THE MINIMUM PUMP OPERATING SPEED (PROGRAMMED INTO THE VFD) SHALL BE 12HZ. A.

PUMP CONTROL9.

TRANSMITTER EXCEEDS 220°F, DDC SHALL ALARM AT BAS (NO TIME DELAY).

IF THE TEMPERATURE AT THE OPERATING HX’S RESPECTIVE LEAVING TEMPERATURED.

SETPOINT”. GENERATE AN ALARM MESSAGE AT BAS “HX ROTATED, TEMPERATURE STILL NOT ATDELAY IF THE WATER TEMPERATURE SETPOINT IS NOT ACHIEVED, THE DDC SHALL

INVESTIGATE CAUSE OF CRITICAL HX PROBLEM.” AFTER THE HX ROTATION AND A TIMEMESSAGE SHALL STATE “ROTATING TO BACK-UP HX DUE TO TEMPERATURE PROBLEM.SHALL ROTATE HEAT EXCHANGER OPERATION. DDC SHALL ALSO ALARM AT BAS. ALARM

IF THE SETPOINT VARIES MORE THAN ±10°F FROM SETPOINT, AFTER TIME DELAY, DDCC.

CLOSED THE LARGEST CONTROL VALVE.

VALVE. UPON A DECREASE IN LOAD, THE OPPOSITE SHALL OCCUR, FIRST MODULATING

UPON CONTINUED INCREASE IN LOAD, MODULATE OPEN THE NEXT LARGER CONTROL

UPON AN INCREASE IN LOAD, FIRST MODULATE OPEN THE SMALLEST CONTROL VALVE.B.

CHANGES BASED ON THE INDICATED RESET SCHEDULE.

RESPECTIVE LEAVING TEMPERATURE TRANSMITTER TSW-2 OR TSW-3. THE SETPOINT

OPERATING HEAT EXCHANGER TO PRODUCE THE REQUIRED SETPOINT AT THE HX’STHE DDC SHALL SEQUENTIALLY MODULATE THE STEAM CONTROL VALVES OF THEA.

STEAM VALVE CONTROL8.

OPERATION.

±10°F OF SETPOINT DDC SHALL ALARM AND SWITCH BACK TO LEAD HEAT EXCHANGER

THE LEAVING WATER TEMPERATURE AT THE LAG HX TRANSMITTER IS NOT WITHIN

AFTER THE 5 MINUTE TIME DELAY (ADJ), IF DPT-1 IS NOT WITHIN 2PSI OF SETPOINT ORC.

VALVES. 5 MINUTES LATER, LEAD PUMP SHALL STOP.

TEMPERATURE CONTROL TO STABILIZE, DDC SHALL CLOSE THE LEAD HX’S STEAMAFTER A 5 MINUTE TIME DELAY (ADJ) TO ALLOW THE LAG HEAT EXCHANGER

HX'S RESPECTIVE DISCHARGE TEMPERATURE TRANSMITTER (TSW-2 OR TSW-3).

VALVES TO MAINTAIN THE CURRENT HWH SETPOINT BY CONTROLLING TO THE LAG

MAINTAIN THE DPT-1 SETPOINT. THE DDC SHALL CONTROL THE LAG HX STEAM

LEAD PUMP’S SPEED AND THEN THE SPEED OF BOTH PUMPS WILL BE CONTROLLED TOLAG PUMP WILL RAMP UP GRADUALLY (AS SET IN THE VFD) UNTIL IT MATCHES THE

TO ROTATE OPERATION, DDC SHALL FIRST START THE LAG PUMP. THE SPEED OF THEB.

CONDITION DESCRIBED IN OTHER SEQUENCE PARAGRAPHS.

EXCHANGER ROTATION SHALL ALSO OCCUR WHEN INITIATED BY AN OPERATING

ROTATED WEEKLY IN OR OUT OF SERVICE BY THE DDC TO EQUALIZE RUN TIME. HEAT

EACH HEAT EXCHANGER, STEAM CONTROL VALVE STATION, AND PUMP SHALL BEA.

7.ROTATING HEAT EXCHANGER OPERATION

DETAILED SEQUENCE

PRESSURE OR TEMPERATURE SETPOINT CAN’T BE MAINTAINED. THE DDC SHALL ROTATE TO THE OTHER HEAT EXCHANGER/PUMP SET IF THE DIFFERENTIAL6.

BE MODULATED TO ACHIEVE DPT-1 SETPOINT.

LEAVING TEMPERATURE SENSOR. THE SPEED OF THE ASSOCIATED LEAD PUMP SHALL

EXCHANGER TO ACHIEVE THE SUPPLY WATER SETPOINT AT THE HEAT EXCHANGER’STHE DDC SHALL SEQUENTIALLY CONTROL THE STEAM VALVES OF THE LEAD HEAT5.

THE SYSTEM SHALL OPERATE CONTINUOUSLY.4.

THE MANUAL VALVE IN THE COMMON PUMP CROSS-OVER HEADER SHALL BE CLOSED. 3.

ISOLATION VALVES OPEN.

BOTH PUMPS AND BOTH HEAT EXCHANGERS SHALL HAVE THEIR MANUAL2.

AND HEAT EXCHANGER ARE IDLE.

ONE PUMP AND ONE HEAT EXCHANGER WILL OPERATE WHILE THE OTHER PUMP1.

SUMMARY

SEQUENCE OF OPERATION:

INCLUDE IN SEQUENCE IF REQUIRED.>

MINIMUM <FILL IN GPM> HWH FLOW IS ATTAINED BY <BYPASS? THREE-WAY VALVES?

OUT OF SERVICE WHILE MEETING THE PEAK DIVERSIFIED HWH LOAD.

ONE HEAT EXCHANGER, ONE STEAM CONTROL VALVE STATION, OR ONE PUMP CAN BE

HANDLE APPROXIMATELY <FILL IN PERCENT> OF THE PEAK DIVERSIFIED HWH LOAD.

EACH HEAT EXCHANGER, STEAM CONTROL VALVE STATION, AND PUMP ARE SIZED TO

DESIGN INTENT:

MD 235716 001MD 235716 001.dgn

SEE DETAIL

DRIP TRAP.

CONDENSATE

LOW PRESSURE

(TYP.)

ISOLATION VALVE

SEE DETAIL

DRIP TRAP.

STEAM

A" LOW PRESSURE

(NOTE 1)

STEAM SEPARATOR

(NOTE 1)

SEPARATOR

STEAM

(NOTE 2)

STRAINER

NOTES:

STEAM STRAINER INSTALLATION DETAIL.

ORIENT BASKET PORTION OF STRAINER IN HORIZONTAL POSITION. SEE

INCREASERS SEPARATOR WHEN REQUIRED.

FLOW RATE, BUT NOT LESS THAN DIMENSION "A". PROVIDE ECCENTRIC

EXCEED THAT OF AN EQUIVALENT LENGTH OF PIPE AT THE DESIGN STEAM

PROVIDE SEPARATOR SIZE HAVING A PRESSURE DROP THAT DOES NOT

LOCATE STEAM SEPARATOR AS CLOSE AS POSSIBLE TO CONTROL VALVES.

2.

1.

A" LPS

TOP VIEW

SIDE VIEW

STRAINER

ELBOW DOWN

STRAINER

A" LPS

ELBOW DOWN

NO SCALE

STRAINER INSTALLATION DETAIL

BIB

CAPPED HOSE

VALVE WITH

(DELETE FOR BID DOC'S)DESIGNER NOTES:

COMPLETE ALL MISSING INFORMATION.1.

2.

DG 235716 AND MASTER SPECIFICATION MS 235716 FOR ADDITIONAL INFORMATION.

REVIEW STEAM TO WATER HEAT EXCHANGER SYSTEM DESIGN GUIDELINE3.

REVISE DETAIL ACCORDINGLY.

IN SOME CASES IN MAY MAKE SENSE TO USE ONE SEPARATOR PER CONTROL VALVE

RAMIFICATIONS. ALSO REFER TO NOTE 1. ON STEAM CONTROL STATION DETAIL.

REVIEW MANUFACTURES DATA ON STEAM SEPARATORS FOR PRESSURE DROP

T

T