p-seriesmeus1.mylinkdrive.com/files/pla-a36ea7___puz-a36nka7-bs_product_data_sheet-en.pdfmodel...

8
Job Name: System Reference: Date: Indoor Unit: PLA-A36EA7 Outdoor Unit: PUZ-A36NKA7 PUZ-A36NKA7-BS INDOOR UNIT FEATURES Space-efficient ductless installation Equipped with 3D i-see Sensor TM for enhanced comfort and energy efficiency Airflow settings for high and low ceiling applications Individual vane settings for direct/indirect airflow control or variable airflow patterns Knockouts for outside-air intake and branch-duct run Filter indicator signal Easy-to-clean, washable filter (optional high-efficiency filter available - requires multi-function casement) Built-in condensate lift mechanism Ideal for retail shops, classrooms, office spaces, conference centers, building lobbies, and more OUTDOOR UNIT FEATURES Variable speed INVERTER-driven compressor Suction accumulator pre-charged with refrigerant volume for piping length up to 100 ft (70 ft. for A12/18/24/30) 24-hour continuous operation (cooling mode) High pressure protection Fast restart due to bypass valve make it ideal for equipment cooling applications, such as data centers Superior energy and operational efficiency SUBMITTAL DATA: PLA-A36EA7 & PUZ-A36NKA7(-BS) 36,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM Specifications are subject to change without notice. © 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved. P-SERIES

Upload: others

Post on 24-Dec-2019

10 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: P-SERIESmeus1.mylinkdrive.com/files/PLA-A36EA7___PUZ-A36NKA7-BS_Product_Data_Sheet-en.pdfModel Number Indoor Unit PLA-A36EA7 Outdoor Unit PUZ-A36NKA7 PUZ-A36NKA7-BS Cooling1 Maximum

Job Name:

System Reference: Date:

Indoor Unit:PLA-A36EA7

Outdoor Unit:□ PUZ-A36NKA7□ PUZ-A36NKA7-BS

INDOOR UNIT FEATURES• Space-efficient ductless installation • Equipped with 3D i-see SensorTM for enhanced comfort and energy efficiency• Airflow settings for high and low ceiling applications• Individual vane settings for direct/indirect airflow control or variable airflow patterns• Knockouts for outside-air intake and branch-duct run• Filter indicator signal• Easy-to-clean, washable filter (optional high-efficiency filter available - requires multi-function casement)• Built-in condensate lift mechanism• Ideal for retail shops, classrooms, office spaces, conference centers, building lobbies, and more

OUTDOOR UNIT FEATURES• Variable speed INVERTER-driven compressor• Suction accumulator pre-charged with refrigerant volume for piping length up to 100 ft (70 ft. for A12/18/24/30)• 24-hour continuous operation (cooling mode)• High pressure protection• Fast restart due to bypass valve make it ideal for equipment cooling applications, such as data centers• Superior energy and operational efficiency

SUBMITTAL DATA: PLA-A36EA7 & PUZ-A36NKA7(-BS)36,000 BTU/H CEILING-CASSETTE HEAT PUMP SYSTEM

Specifications are subject to change without notice. © 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

P-SERIES

Page 2: P-SERIESmeus1.mylinkdrive.com/files/PLA-A36EA7___PUZ-A36NKA7-BS_Product_Data_Sheet-en.pdfModel Number Indoor Unit PLA-A36EA7 Outdoor Unit PUZ-A36NKA7 PUZ-A36NKA7-BS Cooling1 Maximum

Model Number

Indoor Unit PLA-A36EA7

Outdoor UnitPUZ-A36NKA7

PUZ-A36NKA7-BS

Cooling1

Maximum Capacity Btu/h 36,000

Rated Capacity Btu/h 36,000

Minimum Capacity Btu/h 16,000

Maximum Power Input W 2,780

Rated Power Input W 2,780

Moisture Removal Pints/h 4.5

Sensible Heat Factor 0.86

Power Factor % 93.7

Heating at 47° F2

Maximum Capacity Btu/h 42,000

Rated Capacity Btu/h 38,000

Minimum Capacity Btu/h 18,000

Maximum Power Input W 3,020

Rated Power Input W 2,540

Power Factor % 93.6

Heating at 17° F3

Maximum Capacity Btu/h 25,500

Rated Capacity Btu/h 22,000

Maximum Power Input W 2,550

Rated Power Input W 2,490

Efficiency

SEER 21.8

EER1 12.9

HSPF (IV) 10.4

COP at 47° F2 4.38

COP at 17° F3 2.58

ENERGY STAR® Certified (ENERGY STAR products are third-party certified byan EPA-recognized Certification Body)

Yes

Electrical

Voltage, Phase, Frequency 208 / 230V, 1-phase, 60 Hz

Guaranteed Voltage Range V AC 198 – 253

Voltage: Indoor - Outdoor, S1-S2 V AC 208 / 230

Voltage: Indoor - Outdoor, S2-S3 V DC 24

Voltage: Indoor - Remote controller V DC 12

Recommended Fuse/Breaker Size A 30

Recommended Wire Size (Indoor - Outdoor) AWG 14

Indoor Unit

MCA A 2.00

Fan Motor Full Load Amperage A 0.95

Fan Motor Output W 120

Airflow Rate, Dry CFM 670-850-1020-1200

Airflow Rate, Wet CFM 630-810-980-1160

External Static Pressure in.WG n/a

SPECIFICATIONS: PLA-A36EA7 & PUZ-A36NKA7(-BS)

Specifications are subject to change without notice. © 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Page 3: P-SERIESmeus1.mylinkdrive.com/files/PLA-A36EA7___PUZ-A36NKA7-BS_Product_Data_Sheet-en.pdfModel Number Indoor Unit PLA-A36EA7 Outdoor Unit PUZ-A36NKA7 PUZ-A36NKA7-BS Cooling1 Maximum

Model Number

Indoor Unit PLA-A36EA7

Outdoor UnitPUZ-A36NKA7

PUZ-A36NKA7-BS

Sound Pressure Level dB(A) 32-37-41-44

Drain Pipe Size In. (mm) 1-1/4 (32)

Condensate Lift Mechanism, Max. Distance In. 33-7/16

Heat Exchanger Type Plate fin coil

External Finish Color White Munsell 6.4Y 8.9/0.4

Unit Dimensions // Grille Dimensions

W: In. (mm) 33-1/16 (840) // 37-13/32 (950)

D: In. (mm) 33-1/16 (840) // 37-13/32 (950)

H: In. (mm) 11-3/4 (298) // 1-9/16 (40)

Package Dimensions // Grille Dimensions

W: In. (mm) 35-9/16 // 39-6/16

D: In. (mm) 34-5/16 // 38-3/16

H: In. (mm) 16-9/16 // 4-12/16

Unit Weight // Grille Weight Lbs. (kg) 56 (25) // 11 (5)

Package Weight Lbs. (kg) 77 (35)

Indoor Unit OperatingTemperature Range

Cooling Intake Air Temp (Maximum / Minimum) °F 90 DB, 73 WB / 66 DB, 59 WB

Heating Intake Air Temp (Maximum / Minimum) °F 82 DB / 50 DB

Outdoor Unit

MCA A 25

MOCP A 31

Fan Motor Full Load Amperage A 0.5 + 0.5

Fan Motor Output W 74 + 74

Airflow Rate CFM 3,880

Refrigerant Control Electronic Expansion Valve

Defrost Method Reverse Cycle

Heat Exchanger Type Cross fin

Sound Pressure Level, Cooling1 dB(A) 52

Sound Pressure Level, Heating2 dB(A) 53

Compressor Type Inverter-driven twin rotary

Compressor Model MNB33FBRMC-L

Compressor Rated Load Amps A 8

Compressor Locked Rotor Amps A 13

Compressor Oil Type // Charge oz. FV50S // 45

External Finish Color Ivory Munsell 3Y 7.8/1.1

Base Pan Heater n/a

Unit Dimensions

W: In. (mm) 1050 [41-5/16]

D: In. (mm) 330 + 30 [13+1-3/16]

H: In. (mm) 1338 [52-11/16]

Package Dimensions

W: In. (mm) 42-15/16

D: In. (mm) 17-11/16

H: In. (mm) 56-4/16

SPECIFICATIONS: PLA-A36EA7 & PUZ-A36NKA7(-BS)

Specifications are subject to change without notice. © 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Page 4: P-SERIESmeus1.mylinkdrive.com/files/PLA-A36EA7___PUZ-A36NKA7-BS_Product_Data_Sheet-en.pdfModel Number Indoor Unit PLA-A36EA7 Outdoor Unit PUZ-A36NKA7 PUZ-A36NKA7-BS Cooling1 Maximum

Model Number

Indoor Unit PLA-A36EA7

Outdoor UnitPUZ-A36NKA7

PUZ-A36NKA7-BS

Unit Weight Lbs. (kg) 214 (97)

Package Weight Lbs. (kg) 245 (111)

Outdoor Unit OperatingTemperature Range

Cooling Intake Air Temp (Maximum / Minimum) °F 115 DB / 0* DB

Heating Intake Air Temp (Maximum / Minimum) °F 70 DB, 59 WB / -4 DB, -4 WB

Thermal Lock-out / Re-start Temperatures** °F -8 / -4 DB

RefrigerantType R410A

Charge Lbs, oz 10 lbs, 6 oz

Piping

Gas Pipe Size O.D. (Flared) In.(mm) 5/8 (15.88)

Liquid Pipe Size O.D. (Flared) In.(mm) 3/8 (9.52)

Maximum Piping Length Ft. (m) 165 (50)

Maximum Height Difference Ft. (m) 100 (30)

Maximum Number of Bends 15

Notes

AHRI Rated Conditions(Rated data isdetermined at a fixedcompressor speed)

1Cooling (Indoor // Outdoor) °F 80 DB, 67 WB // 95 DB, 75 WB2Heating at 47°F (Indoor // Outdoor) °F 70 DB, 60 WB // 47 DB, 43 WB3Heating at 17°F (Indoor // Outdoor) °F 70 DB, 60 WB // 17 DB, 15 WB

Conditions 4Heating at 5°F (Indoor // Outdoor) °F 70 DB, 60 WB // -4 DB, -5 WB

*Wind baffles required to operate below 23°F DB in cooling mode. PUZ with wind baffle: 0°F - 115°F.**System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures.

SEACOAST PROTECTION• External Outer Panel: Phosphate coating + Acrylic-Enamel coating• Fan Motor Support: Epoxy resin coating (at edge face)• Separator Assembly; Valve Bed: Epoxy resin coating (at edge face)• “Blue Fin” treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne contaminants.

SPECIFICATIONS: PLA-A36EA7 & PUZ-A36NKA7(-BS)

Specifications are subject to change without notice. © 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Page 5: P-SERIESmeus1.mylinkdrive.com/files/PLA-A36EA7___PUZ-A36NKA7-BS_Product_Data_Sheet-en.pdfModel Number Indoor Unit PLA-A36EA7 Outdoor Unit PUZ-A36NKA7 PUZ-A36NKA7-BS Cooling1 Maximum

High-efficiency Filter Element □ PAC-SH59KF-E

Wireless Remote Controller □ PAR-FL32MA-E

Wireless Remote Receiver □ PAR-FA32MA-E

Signal Receiver □ PAR-SR3LA-E

Backlit, Wall-mounted, Wireless Controller □ MHK1

Portable Central Controller □ MCCH1

Wired MA Controller □ PAR-33MAA

Simple MA Controller □ PAC-YT53CRAU

Touch MA Controller □ PAR-CT01MAU-SB

Wired Remote Sensor □ PAC-SE41TS-E

Lockdown Bracket for Wireless, Hand-held, Remote Controller □ RCMKP1CB

Wireless Temperature and Humidity Sensor □ PAC-USWHS003-TH-1

Outside Air Sensor for MHK1 □ MOS1

Flush Mount Remote Temperature Sensor □ PAC-USSEN001-FM-1

Wireless Interface □ PAC-USWHS002-WF-1

Thermostat Interface □ PAC-US444CN-1

kumo station® □ PAC-WHS01HC-E

USNAP Interface □ PAC-WHS01UP-E

IT Extender □ PAC-WHS01IE-E

BACnet® and MODBUS® Interface □ PAC-UKPRC001-CN-1

External Fan / Heater Control Relay Adapter □ CN24RELAY-KIT-CM3

Connector for CN32 (remote on/off) □ PAC-SE55RA-E

Remote Operation Adapter (with wire terminals for remote ON/OFF and operation status/ error)1 □ PAC-SF40RM-E

Grille (required) □ PLP-40EAEU

Multi-Function Casement □ PAC-SJ41TM-E

Installation/Trim Panels □ PLFY-ITP1

Space Panel □ PAC-SJ38AS-E

Air Outlet Shutter Plate □ PAC-SJ37SP-E

Blue Diamond Sensor Extension Cable—15 Ft. □ C13-103

MegaBlue Advanced Blue Diamond Condensate Pump w/ Reservoir & Sensor □ X87-835 - 110 to 250V

MaxiBlue Advanced Blue Diamond Mini Condensate Pump w/ Reservoir & Sensor (208/230V) up to 48,000 Btu/h[recommended]

□ X87-721 - 208/230V

Drain Pan Level Sensor (Control for indoor unit shut off to prevent drain pan overflow) □ DPLS2

3 Pole Disconnect Switch (30A/600VUL) [fits 2"X4" utility] - Black □ TAZ-MS303

3 Pole Disconnect Switch (30A/600VUL) [fits 2"X4" utility] - White □ TAZ-MS303W1 Unable to use with wireless remote controller

ACCESSORIES: PLA-A36EA7

Specifications are subject to change without notice. © 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Page 6: P-SERIESmeus1.mylinkdrive.com/files/PLA-A36EA7___PUZ-A36NKA7-BS_Product_Data_Sheet-en.pdfModel Number Indoor Unit PLA-A36EA7 Outdoor Unit PUZ-A36NKA7 PUZ-A36NKA7-BS Cooling1 Maximum

Twinning Distribution Pipe (50:50) □ MSDD-50TR-E

Air Outlet Guide □ PAC-SH96SG-E (two pieces arerequired)

Front Wind Baffle □ WB-PA3 (two pieces arerequired)

Drain Socket □ PAC-SG61DS-E

M-NET Converter □ PAC-SF83MA-E

M-NET Converter □ PAC-SJ95MA-E

Control/Service Tool □ PAC-SK52ST

Condensing Unit Mounting Pad 24" x 42" x 3" □ ULTRILITE2

Outdoor Unit Stand—12" High □ QSMS1202M

Outdoor Unit Stand—18" High □ QSMS1802M

Outdoor Unit Stand—24"High □ QSMS2402M

Heavy Duty Wall Mounting Bracket for Outdoor Units—Coated Steel □ QSWB2000M-1

Heavy Duty Wall Mounting Bracket for Outdoor Units—316 Series Stainless Steel □ QSWBSS

3/8" x 5/8" x 10' / 1/2" Lineset (Twin-Tube Insulation) □ MPLS385812T-10

3/8" x 5/8" x 15' / 1/2" Lineset (Twin-Tube Insulation) □ MPLS385812T-15

3/8" x 5/8" x 30' / 1/2" Lineset (Twin-Tube Insulation) □ MPLS385812T-30

3/8" x 5/8" x 50' / 1/2" Lineset (Twin-Tube Insulation) □ MPLS385812T-50

3/8" x 5/8" x 65' / 1/2" Lineset (Twin-Tube Insulation) □ MPLS385812T-65

3/8" x 5/8" x 100' / 1/2" Lineset (Twin-Tube Insulation) □ MPLS385812T-100

ACCESSORIES: PUZ-A36NKA7(-BS)

Specifications are subject to change without notice. © 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Page 7: P-SERIESmeus1.mylinkdrive.com/files/PLA-A36EA7___PUZ-A36NKA7-BS_Product_Data_Sheet-en.pdfModel Number Indoor Unit PLA-A36EA7 Outdoor Unit PUZ-A36NKA7 PUZ-A36NKA7-BS Cooling1 Maximum

PLA-A36EA7

6O

UTLIN

ES AN

D D

IMEN

SION

S

12(305)OR MORE

177-3/16(4500)OR LESS

FE

REFRIGERANT PIPEΦ6.35FLARED CONNECTION 1/4F

REFRIGERANT PIPE{12.7FLARED CONNECTION 1/2F

REFRIGERANT PIPEΦ9.52FLARED CONNECTION 3/8F

REFRIGERANT PIPE{15.88FLARED CONNECTION 5/8F

A B

9-1/2(241)

11-1/16 (281)

11-3/4 (298)

10-3/16 (258) 3(76)

3-1/8(79.5)

C

3(76.5)

DMODELS

PLA-A.EA7*:12/18/24/30/36/42

137-13/16(3500)OR LESS

10-7/16(265)OR MORE

WALL

CEILI

NG H

EIGH

TSP

ACE

IN TH

E C

EILIN

G

GRILLE 70-7/8(1800mm) OR MORE FROM FLOOR

INDOOR UNITINDOOR UNIT

FLOOR

BETWEEN INDOOR UNIT

OBSTACLECEILING

OR MORE118-1/8(3000mm)

59-1/16(1500mm) OR MORE

39-3/

8 OR

MORE

(1000

mm)

1/4OR

MOR

E(7m

m)

EF

BETWEEN THE TOP OF UNITAND CEILING SLAB

CEILING

{3-15/16({100)CUTOUT HOLE

{4-15/16({125) BURRING HOLE PITCH SELF-TAP 4 SCREWS:3 PLACES

DETAILS OF FRESH AIR INTAKE HOLE

6-1/

4(1

58)

120°

120°

21

MAIN UNITSUSPENSION BOLTM10 OR W3/8

INDOOR UNIT/OUTDOOR UNITCONNECTING WIRE,POWER SUPPLY WIRE ENTRY

GRILLE

DRAIN PIPEVP-25 CONNECTION(CONNECTED THE ATTACEDDRAIN SOCKET)

CEILING

SUSPENSION BOLTLOWER EDGE

THE BOTTOM OF I-SEE SENSOR (17

)+5 0 0+3/16

2-5/

16(5

8)1-

15/1

6 TO

2-3

/4(5

0-70

)5-

1/2

(140

)6-

11/1

6(1

70)

4-1/

8(1

05)

7-1/

2(1

90)

11/1

6A

1-9/

16(4

0)B

2-3/8(60)

24-3/4(628)

GRILLE

CEILING

{6-7/8({175) BURRING HOLE PITCHSELF-TAP 4 SCREWS:4 PLACES(CONNECTING TO BRANCH DUCT)

{5-7/8({150) CUTOUT HOLE(CONNECTING TO BRANCH DUCT)

SELF-TAP 4 SCREWS:14 PLACES(CONNECTING TO BRANCH DUCT)

13-3/4×3-15/16(350×100) CUTOUT HOLE(CONNECTING TO BRANCH DUCT)

6-9/16(167)

6-1/8(155)

15-3

/8(3

90) 3-

9/16

(90)

3-15

/16

(100

)3-

15/1

6(1

00)

3-9/

16(9

0)

13-3

/4(3

50)

5-1/8(130)

3-15/16(100)

70°

BRANCH DUCT HOLE

(CEILING HOLE)

(SUSPENSION BOLT PITCH)

(SUS

PENS

ION

BOLT

PITC

H)

(CEI

LING

HOLE

)

FRESH AIR INTAKE HOLE

BRANCH DUCT HOLE

REMOTE CONTROLLER WIRE ENTRY

INDOOR UNIT/OUTDOOR UNITCONNECTINGTERMINAL BLOCK BRANCH DUCT

HOLE

+40 0

0+1-9/

16(66

0 )

REMOTECONTROLLERTERMINAL BLOCK

BRANCH DUCT HOLE

13/1

6 TO

1-3

/4(2

0-45

)33

-7/8

TO

35-

13/1

6(86

0-91

0)

13/1

6(2

0)26

13/1

6 TO

1-3

/4(2

0-45

)

13/16 TO 1-3/4(20-45)

13/16 TO 1-3/4(20-45)

31-5/16 (795)33-7/8 TO 35-13/16(860-910)

33-1/16(840)

33-1

/16(

840)

5-11

/16

(145

)

5-11/16(145)

1/4(

6)5-11/16(145)

5-11

/16(

145)

13/1

6(2

0)

8-3/4(222)

7-5/8(193)

3-1/

8(79

.5)

5-1/

4(1

33)

D C

REMOTE CONTROLLER WIRE ENTRY

GRILLE

{5-7/8({150) CUTOUT HOLE(CONNECTING TO BRANCH DUCT)

{6-7/8({175) BURRING HOLE PITCHSELF-TAP 4 SCREWS:4 PLACES(CONNECTING TO BRANCH DUCT)

CEILING

17-1

1/16

(450

)

70°

COMPANY NAME

I-SEE SENSOR CORNER PANELSOME GRILLES DO NOT HAVE THIS PART.*CAN INSTALL TO THE CORNER EXCEPT DRAIN PIPE CORNER (NEED TO FUNCTION SETTING BY REMOTE CONTROLLER)

AIR INTAKE GRILLE

CORNER POCKET

DRAIN HOLE

AUTO VANE

(AIR OUTLET HOLE)

(AIR

OUT

LET H

OLE)

(AIR

INTA

KE H

OLE)

(AIR INTAKE HOLE)

OPTIONAL PART:SIGNAL RECEIVER

20-7

/8(5

30)

20-7/8(530)

37-3/8(950)

37-3

/8(9

50)

20(508)

20(5

08)

3-1/2(89)

1-7/16(37)

3-1/

2(8

9)1-

7/16

(37)

DEFROST/STAND BY LAMPOPERATION LAMPRECEIVER

EMERGENCY OPERATION SWITCH <HEATING>AND EMERGENCY UP/DOWN SWITCH<DOWN>

EMERGENCY OPERATION SWITCH <COOLING>AND EMERGENCY UP/DOWN SWITCH<UP>

DETAILS OF SIGNAL RECEVER

VANE MOTOR

NOTE1.CHOOSE THE GRILLE AMONG THE DEDICATED GRILLES.2.REINFORCE THE SUSPENSION BOLT FOR EARTHQUAKE-RESISTANCE AS NEEDED.3.FOR THE SUSPENSION BOLT, USE M10 OR W3/8.

(PROCURED AT THE LOCAL SITE.)4.FOR DRAIN PIPE, USE VP-25(O.D. n1-1/4''({32) PVC TUBE).DRAIN PUMP INCLUSION.

RAISE IS MAX 33-7/16''(850mm) FROM THE CEILING.5.ELECTRICAL BOX MAY BE REMOVED FOR THE SERVICE PURPOSE.MAKE SURE TO SLACK THE ELECTRICAL WIRE LITTLE BIT FOR

CONTROL/POWER WIRES CONNECTION.6.THE HEIGHT OF THE INDOOR UNIT IS ABLE TO BE ADJUSTED

WITH THE GRILLE ATTACHED.7.REQUIRES "E" OR MORE SPACE BETWEEN TRANSOM AND CEILING FOR THE INSTALLATION.8.WHEN INSTALLING THE BRANCH DUCTS, BE SURE TO INSULATE ADEQUATELY.

OTHERWISE CONDENSATION AND DRIPPING MAY OCCUR.(IT BECOMES THE CAUSE OF DROPLET OR DROPLET DRIPPING.)

9.AS FOR NECESSARY INSTALLATION/SERVICE SPACE, PLEASE REFER TO THE RIGHT AT FIGURE.

10.FOR THE INSTALLATION OF THE OPTIONAL HIGH EFFICIENCY FILTER ORMULTI-FUNCTIONAL CASEMENT,REFER TO SPECIAL DRAWING.

Unit: inch (mm)

DIMENSIONS: PLA-A36EA7 & PUZ-A36NKA7 (-BS)

Specifications are subject to change without notice. © 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.

Page 8: P-SERIESmeus1.mylinkdrive.com/files/PLA-A36EA7___PUZ-A36NKA7-BS_Product_Data_Sheet-en.pdfModel Number Indoor Unit PLA-A36EA7 Outdoor Unit PUZ-A36NKA7 PUZ-A36NKA7-BS Cooling1 Maximum

PUZ-A36NKA7(-BS)

16

PUZ-A

36NK

A7

PUZ-A

42NK

A7

PUY-A

36NK

A7

PUY-A

42NK

A7

PUZ-A

36NK

A7-B

S PU

Z-A42N

KA

7-BS

PUY-A

36NK

A7-B

S PU

Y-A42N

KA

7-BS

Bottom piping hole(Knockout)

Drain hole(5-ø33<1-5/16>)

154

<6-1

/16>

136

<5-1

1/32

>

81 <3-3/16>

45 <1-25/32>

110 <14-11/32>160

<6-5/16>160

<6-5/16>160

<6-5/16>

86<3

-3/8

>

Rear Air Intake

Handle for moving

Handle for moving

Side Air Intake

12

Handle for moving

Handle for moving

Service panel

Earth terminal Terminal connectionLeft ... Power supply wiringRight ... Indoor/Outdoor wiring

*1 4

42<1

7-2/

5>

1063

<41-

7/8>

632

<24-

7/8>

*1 4

50<1

7-23

/32>

26<1

-1/3

2>36

9<1

4-17

/32>

1338

<52-

11/1

6>

362 <14-1/4>1050 <41-11/32>

Air intake

Front piping cover

Rear piping cover

2-12×36 Oval holes(Foundation Bolt M10<W3/8>)

Installation Feet

2-U Shaped notched holes(Foundation Bolt M10<W3/8>)

225 <8-27/32>

42 <1-21/32>60 <2-3/8>

25<3

1/32

>33

0<1

3>

225 <8-27/32>600 <23-5/8>

70 <2-3/4>

417

<16-

13/3

2>

28<1

-3/3

2>37

0<1

4-9/

16>

19<3

/4>

40 <1-9/16> 53 <2-3/32>

56 <2-7/32>

0

Conduit hole(ø 24<15/16>knockout)

Conduit hole(ø 37<1-15/32>knockout)

Rear trunking hole(Knockout)

Rear piping hole(Knockout)

75 <2-15/16>

92 <3-5/8>

73<2

-7/8

>60

<2-3

/8>

5<3/

16>

26<1

-1/3

2>

27<1

-1/1

6>55

<2-3

/16>

55 <2-3/16> 60 <2-3/8>

ø 92<3-5/8>

Conduit hole(ø 24<15/16>knockout)

Front piping hole(Knockout)

Front trunking hole(Knockout)

Conduit hole(ø 37<1-15/32>knockout)

26<1

-1/3

2>

92 <3-5/8> 27<1

-1/1

6>55

<2-3

/16>

73<2

-7/8

>

75 <2-15/16>

55 <2-3/16>60 <2-3/8>

ø 92<3-5/8>

Right trunking hole(Knockout)

Conduit hole(ø 37<1-15/32>knockout)

Conduit hole(ø 24<15/16>knockout)

Right piping hole(Knockout)

73<2

-7/8

>61

<2-3

/8>

5<3/

16>

29 <1-5/32>

27<1

-1/1

6>26

<1-1

/32>

92<3

-5/8

>

53 <2-3/32> 60 <2-3/8>

55 <2-3/16>

92 <3-5/8>

ø 92<3-5/8>

Min.

Min.

Min.

Min.

Service space Min.

150

<5-2

9/32

>50

0<1

9-11

/16>

500<19-11/16>

15 <3/5>

50<2> Ma

x.30

<1-3

/16>

( )

21 ... Refrigerant GAS pipe connection (FLARE) ø15.88(5/8F)

... Refrigerant LIQUID pipe connection (FLARE) ø9.52(3/8F)

*1 ... Indication of STOP VALVE connection location.

Piping Knockout Hole Details

Example of Notes

FREE

Min. 15mm<3/5>

Min. 15mm<3/5>

Min. 1000mm<39-3/8>

Min. 150mm<5-29/32>

Piping and wiring connectionscan be made from 4 directions:FRONT, Right, Rear and Below.

4 PIPING-WIRING DIRECTIONS3 FOUNDATION BOLTS2 SERVICE SPACE1 FREE SPACE (Around the unit)Please secure the unit firmlywith 4 foundation (M10<W3/8>) bolts.(Bolts and washers must be purchased locally.)

Dimensions of space neededfor service access areshown in the below diagram.

The diagram below shows a basic example.Explantion of particular details aregiven in the installation manuals etc.

<Foundation bolt height>

Air Discharge

Rear Air Intake

Side Air Intake

1/2 Conduitattachment

ø 22.2<7/8>ø 27.8<1-3/32>

When installing the conduit.Set the attachment to the inner side of each panel.

3/4 Conduitattachment

Scale 1:5

60 <2-3/8> 22.5 <7/8>

5<3/

16>

24.7

<31/

32>

100<3-15/16>

FOUNDATION

OC

H636

Unit: mm<in>

FORM# PLA-A36EA7 / PUZ-A36NKA7(-BS) - 201810

1340 Satellite Boulevard, Suwanee, GA 30024Toll Free: 800-433-4822 www.mehvac.com

DIMENSIONS: PLA-A36EA7 & PUZ-A36NKA7 (-BS)

Specifications are subject to change without notice. © 2018 Mitsubishi Electric Trane HVAC US LLC. All rights reserved.