Job Name:
System Reference: Date:
Indoor Unit:PLA-A18EA7
Outdoor Unit:□ PUY-A18NKA7□ PUY-A18NKA7-BS
INDOOR UNIT FEATURES• Space-efficient ductless installation • Equipped with 3D i-see SensorTM for enhanced comfort and energy efficiency• Airflow settings for high and low ceiling applications• Individual vane settings for direct/indirect airflow control or variable airflow patterns• Knockouts for outside-air intake and branch-duct run• Filter indicator signal• Easy-to-clean, washable filter (optional high-efficiency filter available - requires multi-function casement)• Built-in condensate lift mechanism• Ideal for retail shops, classrooms, office spaces, conference centers, building lobbies, and more
OUTDOOR UNIT FEATURES• Variable speed INVERTER-driven compressor• Suction accumulator pre-charged with refrigerant volume for piping length up to 100 ft (70 ft. for A12/18/24/30)• Low ambient cooling down to -20ºF providing 100% capacity (only for PUY models with wind baffles installed)• 24-hour continuous operation (cooling mode)• High pressure protection• Fast restart due to bypass valve make it ideal for equipment cooling applications, such as data centers• Superior energy and operational efficiency
SUBMITTAL DATA: PLA-A18EA7 & PUY-A18NKA7(-BS)18,000 BTU/H CEILING-CASSETTE AIR-CONDITIONING SYSTEM
Specifications are subject to change without notice. Copyright © 2018 Mitsubishi Electric US, Inc.
P-SERIES
Model Number
Indoor Unit PLA-A18EA7
Outdoor UnitPUY-A18NKA7
PUY-A18NKA7-BS
Cooling*1
Maximum Capacity Btu/h 18,000
Rated Capacity Btu/h 18,000
Minimum Capacity Btu/h 8,000
Maximum Power Input W 1,250
Rated Power Input W 1,250
Moisture Removal Pints/h 2.4
Sensible Heat Factor 0.85
Power Factor % 95.3
Efficiency
SEER 24.6
EER *1 14.4
ENERGY STAR® Certified (ENERGY STAR products are third-party certified by an EPA-recognized Certification Body)
Yes
Electrical
Voltage, Phase, Frequency 208 / 230V, 1-phase, 60 Hz
Guaranteed Voltage Range V AC 198 – 253
Voltage: Indoor - Outdoor, S1-S2 V AC 208 / 230
Voltage: Indoor - Outdoor, S2-S3 V DC 24
Voltage: Indoor - Remote controller V DC 12
Recommended Fuse/Breaker Size A 15
Recommended Wire Size (Indoor - Outdoor) AWG 14
Indoor Unit
MCA A 1.00
Fan Motor Full Load Amperage A 0.36
Fan Motor Output W 50
Airflow Rate, Dry CFM 420-460-570-600
Airflow Rate, Wet CFM 380-420-530-560
External Static Pressure in.WG n/a
Sound Pressure Level dB(A) 28-29-31-32
Drain Pipe Size In. (mm) 1-1/4 (32)
Condensate Lift Mechanism, Max. Distance In. 33-7/16
Heat Exchanger Type Plate fin coil
External Finish Color White Munsell 6.4Y 8.9/0.4
SPECIFICATIONS: PLA-A18EA7 & PUY-A18NKA7(-BS)
Specifications are subject to change without notice. Copyright © 2018 Mitsubishi Electric US, Inc.
Model Number
Indoor Unit PLA-A18EA7
Outdoor UnitPUY-A18NKA7
PUY-A18NKA7-BS
Unit Dimensions // Grille Dimensions
W: In. (mm) 33-1/16 (840) // 37-13/32 (950)
D: In. (mm) 33-1/16 (840) // 37-13/32 (950)
H: In. (mm) 10-5/32 (258) // 1-9/16 (40)
Package Dimensions // Grille Dimensions
W: In. (mm) 35-9/16 // 39-6/16
D: In. (mm) 34-5/16 // 38-3/16
H: In. (mm) 15 // 4-12/16
Unit Weight // Grille Weight Lbs. (kg) 46 (21) // 11 (5)
Package Weight Lbs. (kg) 68 (31)
Indoor UnitOperatingTemperatureRange
Cooling Intake Air Temp (Maximum / Minimum) °F 90 DB, 73 WB / 66 DB, 59 WB
Outdoor Unit
MCA A 11
MOCP A 28
Fan Motor Full Load Amperage A 0.50
Fan Motor Output W 46
Airflow Rate CFM 1,590
Refrigerant Control Electronic Expansion Valve
Heat Exchanger Type Cross fin
Sound Pressure Level, Cooling*1 dB(A) 44
Sound Pressure Level, Heating*2 dB(A) 46
Compressor Type INVERTER-driven twin rotary
Compressor Model SNB130FNCM2
Compressor Rated Load Amps A 7
Compressor Locked Rotor Amps A 12
Compressor Oil Type // Charge oz. FV50S // 16
External Finish Color Ivory Munsell 3Y 7.8/1.1
Base Pan Heater n/a
Unit Dimensions
W: In. (mm) 31-13/16 + 7/16 (809+62)
D: In. (mm) 11-3/16 (300)
H: In. (mm) 24-13/16 (630)
SPECIFICATIONS: PLA-A18EA7 & PUY-A18NKA7(-BS)
Specifications are subject to change without notice. Copyright © 2018 Mitsubishi Electric US, Inc.
Model Number
Indoor Unit PLA-A18EA7
Outdoor UnitPUY-A18NKA7
PUY-A18NKA7-BS
Package Dimensions
W: In. (mm) 37-1/16
D: In. (mm) 16-3/16
H: In. (mm) 27-7/16
Unit Weight Lbs. (kg) 99 (44)
Package Weight Lbs. (kg) 110 (50)
Outdoor UnitOperatingTemperatureRange
Cooling Intake Air Temp (Maximum / Minimum) °F 115 DB / -20* DB
RefrigerantType R410A
Charge Lbs, oz 4 lbs, 14 oz
Piping
Gas Pipe Size O.D. (Flared) In.(mm) 1/2 (12.7)
Liquid Pipe Size O.D. (Flared) In.(mm) 1/4 (6.35)
Maximum Piping Length Ft. (m) 165 (50)
Maximum Height Difference Ft. (m) 100 (30)
Maximum Number of Bends 15
AHRI Rated Conditions (Rateddata is determined at a fixedcompressor speed)
*1 Cooling (Indoor // Outdoor) °F 80°F DB, 67°F WB // 95°F DB, 75°F WB
Notes*Wind baffles required to operate below 23°F DB in cooling mode. PUY with wind baffle: -20°F - 115°F. Refer to windbaffle documentation for further information.**System cuts out in heating mode to avoid thermistor error and automatically restarts at these temperatures
SEACOAST PROTECTION• External Outer Panel: Phosphate coating + Acrylic-Enamel coating• Fan Motor Support: Epoxy resin coating (at edge face)• Separator Assembly; Valve Bed: Epoxy resin coating (at edge face)• “Blue Fin” treatment is an anti-corrosion treatment that is applied to the condenser coil to protect it against airborne
contaminants.
Notes:
SPECIFICATIONS: PLA-A18EA7 & PUY-A18NKA7(-BS)
Specifications are subject to change without notice. Copyright © 2018 Mitsubishi Electric US, Inc.
High Efficiency (MERV 10) Filter Element (req. PAC-SJ41TM-E Multi-Function Casement) □ PAC-SH59KF-E
Grille with 3D i-see SensorTM □ PLP-40EAEU
Installation/Trim Panels □ PLFY-ITP1
Air Outlet Shutter Plate □ PAC-SJ37SP-E
Multi-functional Casement □ PAC-SJ41TM-E
3-Pole Disconnect Switch (30A/600V/UL) [fits 2" X 4" utility box] □ TAZ-MS303
Drain Pan Level Sensor (Control for indoor unit shut off to prevent drain pan overflow) □ DPLS2
MaxiBlue Advanced Blue Diamond Mini-Condensation pump w/ Reservoir &Sensor (110V) up to 48,000 Btu/h [recommended]
□ X87-711 - 110
MaxiBlue Advanced Blue Diamond Mini-Condensation pump w/ Reservoir & Sensor(208/230V) up to 48,000 Btu/h [recommended]
□ X87-721 - 208/230
Extension Cord for Blue Diamond Pump □ C13-103
MegaBlue Blue Diamond Condensate Pump (110-230V) up to 170,000 Btu/h □ X87-835
Remote Sensor (extensible) □ PAC-SE41TS-E
Connector for CN32 (remote on/off) □ PAC-SE55RA-E
Remote Operation Adapter (w/ wire terminals for remote ON/OFF & operation status/error) □ PAC-SF40RM-E*1
External Fan / Heater Control Relay Adapter □ CN24RELAY-KIT-CM3
Backlit, Wall-mounted, Wireless □ MHK1
Wireless Remote Controllers □ MRCH1
Wireless Receiver □ MFH1
Portable Central Controller □ MCCH1
Outside Air Sensor □ MOS1
Wireless Adapter □ PAC-USWHS002-WF-1
BACnet® and Modbus Interface □ PAC-UKPRC001-CN-1
Wall-mounted, Wired □ PAC-YT53CRAU-J
Wired Remote Controller □ PAR-33MAA-J
T-STAT Interface □ PAC-US444CN-1
Signal Receiver □ PAR-SR3LA-E
Simple Remote Controller □ PAC-YT53CRAU
Wireless Remote Controller □ PAR-FL32MA-E
Wire for Remote ON/OFF with CN32 Connector □ PAC-715AD
Lockdown Bracket for Wireless, Hand-held, Remote Controllers □ RCMKP1CB*1 Unable to use with wireless remote controller
ACCESSORIES: PLA-A18EA7
Specifications are subject to change without notice. Copyright © 2018 Mitsubishi Electric US, Inc.
Air Outlet Guide □ PAC-SJ07SG-E
Front Wind Baffle □ WB-PA4
Side Advanced Wind Baffle □ WB-SD4
Rear Advanced Wind Baffle □ WB-RE4
Hail Guard □ HG-A5
Drain Socket □ PAC-SJ08DS-E
Centralized Drain Pan □ PAC-SG63DP-E
Control/Service Tool □ PAC-SK52ST
Wall Mounting Bracket (Powder-coated Steel) □ QCWB2000M-1
Wall Mounting Bracket (316 Series Stainless Steel) □ QSWBSS
M-NET Control Adapter for Building Management System □ PAC-SJ19MA-E
Outdoor Unit Mounting Pad 16" x 36" x 3" □ ULTRILITE1
Outdoor Unit 3-1/4 inch Mounting Base - Pair (Plastic) □ DSD-400N
MiniSplit Mounting Stand-Single Fan Models - 12" □ QSMS1201M
MiniSplit Mounting Stand-Single Fan Models - 18" □ QSMS1801M
MiniSplit Mounting Stand-Single Fan Models - 24" □ QSMS2401M
1/4 x 1/2 x 15' / 1/2" Lineset (Twin-Tube Insulation) □ MLS141212T-15
1/4 x 1/2 x 30' / 1/2" Lineset (Twin-Tube Insulation) □ MLS141212T-30
1/4 x 1/2 x 50' / 1/2" Lineset (Twin-Tube Insulation) □ MLS141212T-50
1/4 x 1/2 x 65' / 1/2" Lineset (Twin-Tube Insulation) □ MLS141212T-65
1/4 x 1/2 x 100' / 1/2" Lineset (Twin-Tube Insulation) □ MLS141212T-100
ACCESSORIES: PUY-A18NKA7(-BS)
Specifications are subject to change without notice. Copyright © 2018 Mitsubishi Electric US, Inc.
PLA-A18EA7 6O
UTLIN
ES AN
D D
IMEN
SION
S
12(305)OR MORE
177-3/16(4500)OR LESS
FE
REFRIGERANT PIPEΦ6.35FLARED CONNECTION 1/4F
REFRIGERANT PIPE{12.7FLARED CONNECTION 1/2F
REFRIGERANT PIPEΦ9.52FLARED CONNECTION 3/8F
REFRIGERANT PIPE{15.88FLARED CONNECTION 5/8F
A B
9-1/2(241)
11-1/16 (281)
11-3/4 (298)
10-3/16 (258) 3(76)
3-1/8(79.5)
C
3(76.5)
DMODELS
PLA-A.EA7*:12/18/24/30/36/42
137-13/16(3500)OR LESS
10-7/16(265)OR MORE
WALL
CEILI
NG H
EIGH
TSP
ACE
IN TH
E C
EILIN
G
GRILLE 70-7/8(1800mm) OR MORE FROM FLOOR
INDOOR UNITINDOOR UNIT
FLOOR
BETWEEN INDOOR UNIT
OBSTACLECEILING
OR MORE118-1/8(3000mm)
59-1/16(1500mm) OR MORE
39-3/
8 OR
MORE
(1000
mm)
1/4OR
MOR
E(7m
m)
EF
BETWEEN THE TOP OF UNITAND CEILING SLAB
CEILING
{3-15/16({100)CUTOUT HOLE
{4-15/16({125) BURRING HOLE PITCH SELF-TAP 4 SCREWS:3 PLACES
DETAILS OF FRESH AIR INTAKE HOLE
6-1/
4(1
58)
120°
120°
21
MAIN UNITSUSPENSION BOLTM10 OR W3/8
INDOOR UNIT/OUTDOOR UNITCONNECTING WIRE,POWER SUPPLY WIRE ENTRY
GRILLE
DRAIN PIPEVP-25 CONNECTION(CONNECTED THE ATTACEDDRAIN SOCKET)
CEILING
SUSPENSION BOLTLOWER EDGE
THE BOTTOM OF I-SEE SENSOR (17
)+5 0 0+3/16
2-5/
16(5
8)1-
15/1
6 TO
2-3
/4(5
0-70
)5-
1/2
(140
)6-
11/1
6(1
70)
4-1/
8(1
05)
7-1/
2(1
90)
11/1
6A
1-9/
16(4
0)B
2-3/8(60)
24-3/4(628)
GRILLE
CEILING
{6-7/8({175) BURRING HOLE PITCHSELF-TAP 4 SCREWS:4 PLACES(CONNECTING TO BRANCH DUCT)
{5-7/8({150) CUTOUT HOLE(CONNECTING TO BRANCH DUCT)
SELF-TAP 4 SCREWS:14 PLACES(CONNECTING TO BRANCH DUCT)
13-3/4×3-15/16(350×100) CUTOUT HOLE(CONNECTING TO BRANCH DUCT)
6-9/16(167)
6-1/8(155)
15-3
/8(3
90) 3-
9/16
(90)
3-15
/16
(100
)3-
15/1
6(1
00)
3-9/
16(9
0)
13-3
/4(3
50)
5-1/8(130)
3-15/16(100)
70°
BRANCH DUCT HOLE
(CEILING HOLE)
(SUSPENSION BOLT PITCH)
(SUS
PENS
ION
BOLT
PITC
H)
(CEI
LING
HOLE
)
FRESH AIR INTAKE HOLE
BRANCH DUCT HOLE
REMOTE CONTROLLER WIRE ENTRY
INDOOR UNIT/OUTDOOR UNITCONNECTINGTERMINAL BLOCK BRANCH DUCT
HOLE
+40 0
0+1-9/
16(66
0 )
REMOTECONTROLLERTERMINAL BLOCK
BRANCH DUCT HOLE
13/1
6 TO
1-3
/4(2
0-45
)33
-7/8
TO
35-
13/1
6(86
0-91
0)
13/1
6(2
0)26
13/1
6 TO
1-3
/4(2
0-45
)
13/16 TO 1-3/4(20-45)
13/16 TO 1-3/4(20-45)
31-5/16 (795)33-7/8 TO 35-13/16(860-910)
33-1/16(840)
33-1
/16(
840)
5-11
/16
(145
)
5-11/16(145)
1/4(
6)5-11/16(145)
5-11
/16(
145)
13/1
6(2
0)
8-3/4(222)
7-5/8(193)
3-1/
8(79
.5)
5-1/
4(1
33)
D C
REMOTE CONTROLLER WIRE ENTRY
GRILLE
{5-7/8({150) CUTOUT HOLE(CONNECTING TO BRANCH DUCT)
{6-7/8({175) BURRING HOLE PITCHSELF-TAP 4 SCREWS:4 PLACES(CONNECTING TO BRANCH DUCT)
CEILING
17-1
1/16
(450
)
70°
COMPANY NAME
I-SEE SENSOR CORNER PANELSOME GRILLES DO NOT HAVE THIS PART.*CAN INSTALL TO THE CORNER EXCEPT DRAIN PIPE CORNER (NEED TO FUNCTION SETTING BY REMOTE CONTROLLER)
AIR INTAKE GRILLE
CORNER POCKET
DRAIN HOLE
AUTO VANE
(AIR OUTLET HOLE)
(AIR
OUT
LET H
OLE)
(AIR
INTA
KE H
OLE)
(AIR INTAKE HOLE)
OPTIONAL PART:SIGNAL RECEIVER
20-7
/8(5
30)
20-7/8(530)
37-3/8(950)
37-3
/8(9
50)
20(508)
20(5
08)
3-1/2(89)
1-7/16(37)
3-1/
2(8
9)1-
7/16
(37)
DEFROST/STAND BY LAMPOPERATION LAMPRECEIVER
EMERGENCY OPERATION SWITCH <HEATING>AND EMERGENCY UP/DOWN SWITCH<DOWN>
EMERGENCY OPERATION SWITCH <COOLING>AND EMERGENCY UP/DOWN SWITCH<UP>
DETAILS OF SIGNAL RECEVER
VANE MOTOR
NOTE1.CHOOSE THE GRILLE AMONG THE DEDICATED GRILLES.2.REINFORCE THE SUSPENSION BOLT FOR EARTHQUAKE-RESISTANCE AS NEEDED.3.FOR THE SUSPENSION BOLT, USE M10 OR W3/8.
(PROCURED AT THE LOCAL SITE.)4.FOR DRAIN PIPE, USE VP-25(O.D. n1-1/4''({32) PVC TUBE).DRAIN PUMP INCLUSION.
RAISE IS MAX 33-7/16''(850mm) FROM THE CEILING.5.ELECTRICAL BOX MAY BE REMOVED FOR THE SERVICE PURPOSE.MAKE SURE TO SLACK THE ELECTRICAL WIRE LITTLE BIT FOR
CONTROL/POWER WIRES CONNECTION.6.THE HEIGHT OF THE INDOOR UNIT IS ABLE TO BE ADJUSTED
WITH THE GRILLE ATTACHED.7.REQUIRES "E" OR MORE SPACE BETWEEN TRANSOM AND CEILING FOR THE INSTALLATION.8.WHEN INSTALLING THE BRANCH DUCTS, BE SURE TO INSULATE ADEQUATELY.
OTHERWISE CONDENSATION AND DRIPPING MAY OCCUR.(IT BECOMES THE CAUSE OF DROPLET OR DROPLET DRIPPING.)
9.AS FOR NECESSARY INSTALLATION/SERVICE SPACE, PLEASE REFER TO THE RIGHT AT FIGURE.
10.FOR THE INSTALLATION OF THE OPTIONAL HIGH EFFICIENCY FILTER ORMULTI-FUNCTIONAL CASEMENT,REFER TO SPECIAL DRAWING.
Unit: inch (mm)
DIMENSIONS: PLA-A18EA7 & PUY-A18NKA7 (-BS)
Specifications are subject to change without notice. Copyright © 2018 Mitsubishi Electric US, Inc.
PUY-A18NKA7(-BS)
14
PUZ-A12NKA7 PUZ-A18NKA7 PUY-A12NKA7 PUY-A18NKA7PUZ-A12NKA7-BS PUZ-A18NKA7-BS PUY-A12NKA7-BS PUY-A18NKA7-BS
6 OUTLINES AND DIMENSIONS
1/2 conduit hole
144<5-21/32>
2-{22.2<7/8>
22<7/8>
38<1
-1/2
>24
1<9-
1/2>
Min.100mm<3-15/16>
Piping and wiring connection canbe made from the rear direction only.
*1 In the place where short cycle tends to occur, cooling and heating capacity and power consumption might get lowered 10%. Air outlet guide (optional PAC-SG58SG-E) will help them improve. *2 If air discharges to the wall, the surface might get stained.
2 sides should be open inthe right, left and rear side.
Min.100mm<3-15/16> as long as no obstacle is placed on therear and light-and-left sidesof the unit
*1*2 *1
Air intake
Air discharge4-oval hole
Air intake
Service panel
Connection for liquid pipe
Service panel for charge plug
Service port
Connection for gas pipe
Min.100mm<3-15/16>
Min.500mm<19-11/16>
Min.350mm<13-25/32>
Basi
cally
open
Max
.
<Foundation bolt height>
FOUNDATION
Please secure the unit firmlywith 4 foundation M10<W3/8> bolts.(Bolts, washers and nut must be purchased locally.)
18m
m<2
3/32
>
{33<1-5/16> drain hole
43.6
<1-2
3/32
>15
2<6>
155
400<15-25/32>
347.5<13-11/16>
45.4<1-25/32>
365<
14-3
/8>
330<
13>
300<
11-1
3/16
>
40<1-9/16>
Handle
600<
23-5
/8>
10<3
/8>
300<
11-1
3/16
>
150<5-29/32>287.5<11-11/32>
500<19-11/16>
800<31-1/2>
69<2-23/32>
183<7-7/32>
90<3
-17/
32>
155<
6-3/
32>
23<29/32>
32.5
<1-9
/32>
18<23/32>
FLARE {12.7<1/2>
FLARE {6.35<1/4>
Installation bolt pitch
PIPING-WIRING DIRECTION
Minimum installation space for outdoor unit
Free space around the outdoor unit(basic example)
FOUNDATION BOLTS
Unit: mm<in>
Air discharge
Air intake
Air intake
oval hole2-10×21
drain holeø 42 2-U Shaped notched holes
(Foundation Bolt M10<W 3/8>)
(Foundation Bolt M10<W 3/8>)
330<
13>
300<
11-1
3/16
>
40 <1-19/32>
404.5<15-15/16>
48<1
-29/
32>
360<
14-3
/16>
32.5
<1-9
/32>
500<19-11/16>
Min.500mm<19-11/16>
Min.100mm <3-15/16>
Service portFLARE 12.7 (1/2F)
Connection forgas pipe
FLARE ø
ø
6.35 (1/4F)Connection forliquid pipe
Service panelfor charge plug
Service panelEarth terminal
Terminal connectionLeft ... Power supply wiringRight ... Indoor/Outdoor wiring
23.2<15/16>
99.5
<3-1
5/16
>16
4.5<
6-1/
2>49
2<19
-3/8
>
185.5 <7-5/16>
43 °35 °
2-ø22.2<7/8>1/2 conduit hole
Installation bolt pitch
Handle for moving
22 <7/8>
320<
12-5
/8>
809 <31-7/8> 62 <2-15/32>
154.5 <6-3/32>
310 <12-7/32>
8.5<
11/3
2>
22.3 <29/32>
630
<24-
13/1
6>
Min.100mm<3-15/16>
Basic
ally
open
Min.350mm <13-25/32>
Max.
<Foundation bolt height>
18m
m<2
3/32
>
Free space around the outdoor unit(basic example)
100mm<3-15/16> or more as long asno obstacle is placed on therear and right-and-left sidesof the unit
2 sides should be open in the right, left and rear side.
Please secure the unit firmlywith 4 foundation (M10<W3/8>) bolts.(Bolts, washers and nut must be purchased locally).
FOUNDATION BOLTS
Piping and wiring connection canbe made from the rear direction only.
PIPING-WIRING DIRECTION
FOUNDATION
OCH636
FORM# PLA-A18EA7 / PUY-A18NKA7(-BS) - 201802
1340 Satellite Boulevard, Suwanee, GA 30024Toll Free: 800-433-4822 www.mehvac.com
DIMENSIONS: PLA-A18EA7 & PUY-A18NKA7 (-BS)
Specifications are subject to change without notice. Copyright © 2018 Mitsubishi Electric US, Inc.