P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2. True demand defrost initiated by loss of evaporator efficiency 3. Efficient defrost management and termination Optional Electronic Expansion Valve control Slide P.T2 - 1

Upload: brooke-rumble

Post on 15-Jan-2016

227 views

Category:

Documents


4 download

TRANSCRIPT

Page 1: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

P.1.2

KE2 Evaporator EfficiencySmart Defrost Management

Companion Literature B.1.1

1. Energy savings through precise evaporator control

2. True demand defrost initiated by loss of evaporator efficiency

3. Efficient defrost management and termination

• Optional Electronic Expansion Valve control

• CommunicationsSlide P.T2 - 1

Page 2: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

The basic kinds of defrost controllers:

Slide P.1.2 - 4Copyright 2010 KE2 Therm Solutions, Inc. Washington, Missouri

Time ClockElectromechanical or Electronic Time Initiate-Time Terminate

Reactive -Time DependentMicro-ProcessorTime Initiate-Temperature Terminate

Microprocessor controlled pro-activeKE2 Evaporator Efficiency defrost

3

Page 3: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Slide P.1.2 – 5Copyright 2010 KE2 Therm Solutions, Inc. Washington, Missouri

Evaporator capacity decreases with accumulation of frost

Understanding Evaporator Performance

Page 4: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

P.1.2

KE2 Evaporator EfficiencySmart Defrost Management

1. Up or down arrow to desired room set point

2. Select defrost mode• Electric• Hot Gas• Air

3. Select expansion device• Mechanical TEV• Electric expansion

valve

Copyright 2010 KE2 Therm Solutions, Inc. Washington,

Missouri

Slide P.T2 - 8

KE2 Evap – only requires two inexpensive temperature sensors for defrost control

Page 5: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Change in ΔT indicates need for defrost

Slide P.1.2 - 9Copyright 2010 KE2 Therm Solutions, Inc. Washington, Missouri

Page 6: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

No Defrost Control Established (Baseline Data Only)LOCATION: Osborne

Middle School

Page 7: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Ke2Therm Defrost Control EstablishedLOCATION:

Osborne Middle School

Page 8: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Circle of ConcernValley Park, Mo.

Defrost frequency per average week

Copyright 2010 KE2 Therm Solutions, Inc. Washington,

Missouri

Slide P.T2- 12

Page 9: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Copyright 2010 KE2 Therm Solutions, Inc. Washington, Missouri

Slide P.1.2 - 13

Some examples:

Page 10: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Copyright 2010 KE2 Therm Solutions, Inc. Washington, Missouri

Slide P.1.2 - 14

Some examples:

Page 11: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

“Free cooling” – Latent energy recovery

Copyright 2010 KE2 Therm Solutions, Inc. Washington, Missouri

Slide P.1.2 - 15

Proper fan control during operation provides “free cooling” by sublimating frost to chill room

Page 12: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Typical Pump Down Cycle

Pump-Down Control Liquid Line Solenoid

Temperature Control

Page 13: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Latent energy recovery

Copyright 2010 KE2 Therm Solutions, Inc. Washington, Missouri

Slide P.1.2 - 17

Page 14: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Latent energy recovery - Advantages

Copyright 2010 KE2 Therm Solutions, Inc. Washington, Missouri

Slide P.1.2 - 18

Less dehumidification and shrinkage of product

Reduced need for defrost heat

Energy savings

Highest possible cooling capacity

Even room temperature

Optimal performance of unit cooler

Reduced compressor operation time

Longer compressor life

Re-humidification

Page 15: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Electric defrost based on time

Slide P.1.2 - 19Copyright 2010 KE2 Therm Solutions, Inc. Washington, Missouri

80% additional heat gain (radiation + convection) due to high heater temperature

High coil temperatur

e drives “fog” into the room

Page 16: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Consequences of fogging

Slide P.1.2 - 20Copyright 2010 KE2 Therm Solutions, Inc. Washington, Missouri

Page 17: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Slide P.1.2 - 21Copyright 2010 KE2 Therm Solutions, Inc. Washington, Missouri

Consequences of excessive heat

Page 18: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Pulsed defrost heaters

Slide P.1.2 - 23Copyright 2010 KE2 Therm Solutions, Inc. Washington, Missouri

Ensures lower terminal coil temperature, less energy usage, decreased product heating

Only 20% additional heat gain (radiation + convection) due to heater temperature

Page 19: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Copyright 2010 KE2 Therm Solutions, Inc. Washington, Missouri

Slide P.1.2 - 34

Optional EEV control possible with pressure transducer and suction temperature sensor

Page 20: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Copyright 2010 KE2 Therm Solutions, Inc. Washington, Missouri

Slide P.1.2 - 35

KE2 Evap provides control & communication

Page 21: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Copyright 2010 KE2 Therm Solutions, Inc. Washington, Missouri

Slide P.1.2 - 36

TCP/IP enabled

Page 22: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Copyright 2010 KE2 Therm Solutions, Inc. Washington, Missouri

37

Good Eats #1234

Page 23: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Copyright 2010 KE2 Therm Solutions, Inc. Washington, Missouri

38

Location:Good Eats #1234

[email protected]

Good Eats #1234

Page 24: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Copyright 2010 KE2 Therm Solutions, Inc. Washington, Missouri

39

Location:Good Eats #1234

Page 25: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Osborne Middle School Test

Page 26: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

LOCATION: Osborne Middle School

No Defrost Control Established (Baseline Data Only)

Room Temp +25F

Coil Temp

+100 F

23 Defrosts in 5 Days, Total Time In Defrost

8.4 Hours

Week One

Page 27: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

No Defrost Control Established (Baseline Data Only)

LOCATION: Osborne Middle

SchoolRoom Temp +25F

Coil Temp

+100 F

22 Defrosts in 5 Days, Total Time in Defrost

8.0 Hours

Week Two

Page 28: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Ke2Therm Defrost Control EstablishedLOCATION: Osborne

Middle SchoolRoom Temp +10F

Coil Temp +50 F

9 Defrosts in 5 Days. Total Time in Defrost

1.7 Hours

Week Three

Page 29: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Ke2Therm Defrost Control EstablishedLOCATION:

Osborne Middle School

Room Temp +10F

Coil Temp +50 F

3 Defrosts in 5 Days. Total Time in Defrost

1.0 Hours

Week Four

Page 30: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand
Page 31: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Osborne Middle School

Page 32: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Osborne

Page 33: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Osborne

Page 34: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Osborne

Page 35: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Osborne

11.8%Reducti

on

26.1%Reducti

on

84.2%Reducti

on

Compressor

Fans Heaters

Page 36: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Berkmar Middle School Test

Page 37: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

0

LOCATION: Berkmar Middle

School

No Defrost Control Established (Baseline Data Only)

Week OneRoom Temp +25F

Coil Temp

+100 F

22 Defrosts in 5 Days, Total Time in Defrost

8.0 Hours

Page 38: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

LOCATION: Berkmar Middle

School

No Defrost Control Established (Baseline Data Only)

Week TwoRoom Temp +25F

Coil Temp

+100 F

22 Defrosts in 5 Days, Total Time in Defrost

8.0 Hours

Page 39: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

LOCATION: Berkmar Middle

SchoolKe2Therm Defrost Control Established

Week Three

Room Temp +15F

Coil Temp +50 F

2 Defrosts in 5 Days, Total Time in Defrost

0.7 Hours

Page 40: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

LOCATION: Berkmar Middle

SchoolKe2Therm Defrost Control Established

Week Four

Room Temp +15F

Coil Temp +50 F

2 Defrosts in 5 Days, Total Time in Defrost

0.5 Hours

Page 41: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Berkmar Middle School

Page 42: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Berkmar

Page 43: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Berkmar

Page 44: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Berkmar

Page 45: P.1.2 KE2 Evaporator Efficiency Smart Defrost Management Companion Literature B.1.1 1. Energy savings through precise evaporator control 2.True demand

Berkmar 19.4%Reductio

n

11.4%Reductio

n

94.4%Reductio

n