p20kva9 - aboud car
TRANSCRIPT
GENSETGenerating Set Powered By
P20KVA9Image for illustration purposes only
Engine Make & Model
Origin
Alternator Type
Control Panel
Circuit Breaker Type
Water Cooling System
Mechanical Governor
Electrical Stop Solenoid, Energized to Run
Compact Size
No. of Cylinders / Alignment
Cycle
Aspiration
Injection
Bore, mm
Stroke, mm
Displacement,I
Compression Ratio
Starting
Alternators, Amps
Prime Power
16KWe / 20KVA
UK
Stamford PI144D
Deap Sea - 6110
3 Pole MCCB
4 / In Line
4 - Stroke
Naturally
Indirect
84
100
2.2 16
23.3:1
12V Electric
12V/15A
Standby Power
18KWe / 22KVA
Engine Technical Data
No. of Bearings
Insulation System
Excitation
Voltage Regulator
Protection
Temperature Rise,°C
Regulation
No. of Phases
No. of Poles
Single Bearing
Class H
Self Excited
AS480
IP23
125
±1.0%
3
4
Alternator Technical Data
H(m)
1.25
W(m)
0.52
L(m)
1.45
Weight(kg)
460
Dimensions (m) & Weights (kg)
International Standards
1500rpm, 50 Hz 2.9 4 5.3
Fuel System 50% 75% 100%
Output Ratings
Genset Specifications
Generating Set Model
1500rpm, 50 Hz /400V
- -1800rpm, 60 Hz /440V
Tank Capacity(L)
44
RATING GUIDELINESPRIME POWER rating corresponds to ISO Standard Power for continuousoperation. It is applicable for supplying electrical power at variable load for anunlimited number of hours instead of commercially purchased power. A10 %overload capability for govering purpose is available for this rating.MAXIMUM STANDBY POWER rating corresponds to ISO Standard FuelStop Power. It is applicable for supplying standby electrical power at variable load inareas with well established electrical networks in the event of normal utility powerfailure. No overload capability is available for this rating. 1 hp = 1 kW x 1.36
Engine confirm to ISO 9001:2000, ISO 1400, ISO 10054, ISO 3046, BS 5514, DIN 6271.Alternator confirm to ISO 9001, ISO 14001, BS EN 60034, BS 5000, VDE 0530, NEMAMG32-1, IEC34 CSA C-22.2100, AS 1359, BS 1 6861, B En -6-610002:2001
Perkins 404A22-G1
1800rpm, 60 Hz
*Prime Power (l/hr)
- - -
GENSETGenerating Set Powered By
P20KVA9
Alternator Efficiency
Optional Equipment
Spare Parts Kit (Optional) Genuine - Perkins
Oil filter, full flowFuel filterAir filterFan belt setAlternator belt set
(1)(1)(1)(1)(1)
0.1% of fuelconsumption
Oil Consumption (l/hr)
Oil Sump Capacity,I
Oil System Capacity Include Filters, I
Lubrication System 1500rpm
Engine PowerPrime Power, KWm(hp)Standby Power, KWm(hp)
AlternatorPrime Power, KWe
85.1%
24.7(18.4)27.2(20.3)
16
Performances 1500rpm
-
--
-
-
-
-
-
1800rpm Control Panel Readings
10.6
-
1800rpm
4.4
19.6
1165(33)
51.2(1.45)
16.6
505
10.2
139(3.94)
1500rpm
1500rpm 1800rpm
7
1800rpm
Anti-Vibration Pads
Cooling System
Heat Radiation from Engine and Alternator, Power KW (Standby)
Heat Rejection to Coolant and Lube Oil at Standby Power, KW
Radiator Cooling Air Flow, m3/min (cfm)
Coolant Capacity, I
Intake & Exhaust System
Air Flow Combustion at Standby Power, m3/min(cfm)
Heat Rejection Exhaust at Standby Power , KW
Exhaust Gas Temperature at Standby °C
Max Allowable Back Pres-sure in Exhaust Line, Kpa
Exhaust Gas Flow at Standb y Power, m3 /min(cfm)
Accessories
Oil Drain Pump
Stainless Steel Flexible
Standard Silencer
• AC volts, AC currents, DC volts, frequency, rpm, hour counter, power factor.• Low oil pressure, high water temparature, boost pressure and temperature, KW, KWh, KVA, KVAR, fuel consumoption, relative load• Oil pressure, low oil level, high oil temperature• DC alternator failure, over speed, over crank (Fail to start), over under voltage, over under current, any sensor failure• Low coolant level - Configurable inputs & outputs• Upgradable for GSM network connection, Signal SMS messages.
-
-
-
-
-
-
-
-
•Engine-Coolant heater -Oversize batteries-Extra fuel pre-filter water separator-Battery Disconnector Switch-Electrical Governor•Alternator-Excitation Boost System (EBS)-Upgrade to 3 phase sensing AVR-Qadrature droop kit-Anti-condensation heater-Air inlet filters• General-Upgrade to modular controller for paralleling-Upgrade to 4 pole circuit breaker-Battery charger-Automatic transfer switch-Fuel level switch High / Low for alarm and control-Fuel transfer pump Automatic / Manual-Residential grade silencer-Weather protective and acoustic enclosure.
Fuel Tank Base Frame for 8hrs