p660-1-p660-1(4pp)gb(0612) - fg wilson jeneratör · fg wilson offer a range of optional features...

4
Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. Standby Rating These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). Standard Reference Conditions Note: Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of Output Ratings Ratings and Performance Data Leroy Somer Prime Standby Engine Make & Model: Alternator manufactured for FG Wilson by: Alternator Model: Control Panel: Circuit Breaker Type: Engine Speed: RPM Base Frame: Fuel Tank Capacity: Dimensions and Weights Length (L) mm (in) Width (W) mm (in) Height (H) mm (in) Dry kg (lb) Wet kg (lb) Dry = With Lube Oil Wet = With Lube Oil and Coolant . Generating set pictured may include optional accessories. www.FGWilson.com Fuel Consumption: (100% Load) - Prime Ratings at power factor. Image for illustration purposes only. - Standby Available Options FG Wilson offer a range of optional features to tailor our generating sets to meet your power needs. Options include: A wide range of Sound Attenuated Enclosures A variety of generating set control and synchronising panels Additional alarms and shutdowns A selection of exhaust silencer noise levels For further information on all of the standard and optional features accompanying this product please contact your local Dealer or visit: www.FGWilson.com 2806A-E18TAG1A LL7024F 600.0 kVA 480.0 kW 660.0 kVA 528.0 kW - - - - P660-1 Heavy Duty Fabricated Steel 3 Pole - 1500 1132 (299.0) - 120.3 (31.8) - 133.1 (35.2) 0.8 3900 (153.5) 1461 (57.5) 2156 (84.9) 4264 (9400) 4332 (9550) z H 0 6 z H 0 5 : y c n e u q e r F 400V, 50 Hz Voltage, Frequency Please refer to the output ratings technical data section for specific generator set outputs per voltage. Perkins®

Upload: dangnhan

Post on 25-Apr-2018

215 views

Category:

Documents


2 download

TRANSCRIPT

Prime Rating These ratings are applicable for supplying continuous electrical power(at variable load) in lieu of commercially purchased power. There is nolimitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours.

Standby Rating These ratings are applicable for supplying continuous electrical power (atvariable load) in the event of a utility power failure. No overload ispermitted on these ratings. The alternator on this model is peakcontinuous rated (as defined in ISO 8528-3).

Standard Reference Conditions Note: Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m(328 ft) A.S.L. 30% relative humidity.Fuel consumption data at full load with diesel fuel with specific gravity of

Output Ratings Ratings and Performance Data

Leroy Somer

Prime Standby Engine Make & Model:

Alternator manufactured for FG Wilson by:

Alternator Model:

Control Panel:

Circuit Breaker Type:

Engine Speed: RPM

Base Frame:

Fuel Tank Capacity:

Dimensions and Weights

Length (L)mm (in)

Width (W)mm (in)

Height (H)mm (in)

Drykg (lb)

Wetkg (lb)

Dry = With Lube Oil Wet = With Lube Oil and Coolant

.Generating set pictured may include optional accessories.

www.FGWilson.com

Fuel Consumption:

(100% Load) - Prime

Ratings at power factor.

Image for illustration purposes only.

- Standby

Available Options

FG Wilson offer a range of optional features to tailor our generating sets to meet your power needs. Options include:

A wide range of Sound Attenuated Enclosures

A variety of generating set control and synchronising panels

Additional alarms and shutdowns

A selection of exhaust silencer noise levels

For further information on all of the standard and optional features accompanying this product please contact your local Dealer or visit: www.FGWilson.com

2806A-E18TAG1A

LL7024F

600.0 kVA 480.0 kW 660.0 kVA 528.0 kW

- -- -

P660-1

Heavy Duty Fabricated Steel

3 Pole

-1500

1132 (299.0)

-120.3 (31.8)

-133.1 (35.2)

0.8

3900 (153.5) 1461 (57.5) 2156 (84.9) 4264 (9400) 4332 (9550)

zH 06zH 05:ycneuqerF

400V, 50 Hz

Voltage, Frequency

Please refer to the output ratings technical data section for specificgenerator set outputs per voltage.

Perkins®

Exhaust System

Maximum Allowable Back Pressure: kPa (in Hg)

Exhaust Gas Flow: m³/min (cfm)

Exhaust Gas Temperature: °C (°F)

60 Hz50 Hz

- Prime

- Standby

- Prime

- Standby

Lubrication System

Oil Filter Type:

Total Oil Capacity: l (US gal)

Oil Pan: l (US gal)

Oil Type:

Oil Cooling Method:

Cooling System

Cooling System Capacity: l (US gal)

Water Pump Type:

Heat Rejected to Water & Lube Oil:

kW (Btu/min)

Heat Radiation to Room: Heat radiated from engine and alternator

kW (Btu/min)

Radiator Fan Load: kW (hp)

Radiator Cooling Airflow: m³/min (cfm)

External Restriction to Cooling Airflow: Pa (in H2O)

Designed to operate in ambient conditions up to 50°C (122°F).Contact your local FG Wilson Dealer for power ratings at specific site conditions.

60 Hz50 Hz

- Prime

- Standby

- Prime

- Standby

No. of Cylinders / Alignment:

Cycle:

Bore / Stroke: mm (in)

Induction:

Engine Speed: rpm

Performance

Gross Engine Power: kW (hp)

BMEP: kPa (psi)

Fuel System

Fuel Filter Type:

Recommended Fuel:

Fuel Consumption: l/hr (US gal/hr)

Prime

50 Hz

60 Hz

110% 100% 75% 50%

Load Load Load Load

60 Hz

50 Hz

Standby Load Load Load

50%75%100%

Air Filter Type:

Combustion Air Flow: m³/min (cfm)

Max. Combustion Air Intate Restriction: kPa (in H2O)Cooling Method:

Governing Type:

Governing Class:

Compression Ratio:

Displacement: l (cu. in)

Moment of Inertia: kg m² (lb/in²)

Engine Electrical System:

Weight: kg (lb)

60 Hz50 Hz

- Standby

- Prime

- Standby

- Prime

- Standby

- Prime

- Dry

- Wet

- Voltage / Ground

- Battery Charger Amps

-568 (1054)

-571 (1060)

-96.0 (3390)

-104.0 (3673)

-6.9 (2.0)

Water

53.0 (14.0)

62.0 (16.4)

Eco, Full Flow

API CH4 / CI4

-68.5 (18.1)

Centrifugal

-

-

208.0 (11829)

222.0 (12625)

71.9 (4089)

81.3 (4623)

-9.0 (12.1)

-373.2 (13179)

-125 (0.5)1500 -

Eco Replaceable Element

6 / In Line

4 Stroke

145.0 (5.7)/183.0 (7.2)

Turbocharged Air To AirCharge Cooled

Water

ISO 8528 G2

Electronic

14.5:1

18.1 (1104.5)

7.05 (24091)

24/Negative

70

2050 (4519)

2158 (4758)

2381.0 (345.4) -

-2615.0 (379.3)

-

-

539.7 (724.0)

592.7 (795.0)

----

61.6 (16.3)89.9 (23.7)120.3 (31.8)133.1 (35.2)

-

67.1 (17.7)

-

98.8 (26.1)

-

133.1 (35.2)

Non Canister

-34.0 (1201)

-36.0 (1271)

-6.4 (25.7)

(Based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869,

Class A2 Diesel, BSEN590

Class A2)

smetsyS riAataD lacinhceT enignE 60 Hz50 Hz

Alternator Physical Data

Manufactured for FG Wilson by:

Model:

No. of Bearings:

Insulation Class:

Winding Pitch Code:

Wires:

Ingress Protection Rating:

Excitation System:

AVR Model:

Overspeed: rpm

Voltage Reguation: (Steady state)

Wave Form NEMA = TIF:

Wave Form IEC = THF:

Total Harmonic content LL/LN:

Radio Interference:

Radiant Heat: kW (Btu/min)

- 50 Hz

- 60 Hz

Voltage Prime: Standby:

kVA kW kVA kW

AlternatorPerformance Data:

Data Item

Motor Starting

Capability* kVA

Short Circuit

Capacity** %

Reactances: Per Unit

Xd

X'd

X"d

Reactances shown are applicable to prime ratings.

**With optional permanent magnet generator or AREP excitation.

Leroy Somer

Suppression is in line with European Standard EN61000-6

Voltage Prime: Standby:

kVA kW kVA kW

0.825V042/514 660.0480.0600.0

0.825V032/004 660.0480.0600.0

464.0 4.0150.085 638.0380/220V

60 Hz50 Hz

Alternator Operating Data

3.5553.3193.083

0.1850.1730.160

0.1470.1370.127

124913761475

R450M

AREP

IP23

12

2/3 - 6

H

1

LL7024F

-

39.3 (2235)

4.0%

2.0%

50

+/- 0.5%

2250

415/240V 400/230V 380/220V

*Based on 30% voltage dip at 0.6 power factor and AREP excitation system.

Output Ratings Technical Data 50 Hz Output Ratings Technical Data 60 Hz

003003 300

Dealer contact details:

Documentation

Generating Set Standards

Warranty

General Information

FG Wilson manufactures product in the following locations:Northern Ireland • Brazil • China • India • USAWith headquarters in Northern Ireland, FG Wilson operates through a Global Dealer Network.

FG Wilson is a trading name of Caterpillar (NI) Limited.

In line with our policy of continuous product development, we reserve the right to change specification without notice. P660-1/4PP/0514/GB