Before installing or maintaining the luminary, make sure all power isWARNING:.TURNED OFF
Verify that supply voltage is correct by comparing it with the label information on allfixtures.Make all connections in accordance with the NEC requirements, and make sure allluminaries are properly secured to prevent any wire complications. This luminary isto always be installed with the lens facing down and it is not to exceed themaximum ambient temperature rating noted on the specification sheet.
FALC Series LED Area Light Installation Guide
Need help? Tech help line: (800) 988-6386 Email: [email protected] Website: www.paclights.com
Copyright © 2020 PacLights All Rights Reserved Note: Instructions are subject to change at any time without notice
FALC200, FALC240, FALC300 FALC080, FALC100, FALC150
02-00041-20423
Page 1 of 7
Connect the ACL and the ACN from the FALC Fixture to the conduit with the AC Power Supply Cable. Follow the Wiring Diagram provided.
AC Power Supply
GROUND [GREEN]
NEUTRAL [WHITE]
HOT [BLACK]
INP
UT
FALC FIXTURE
FALC Initial Set-UpSet the Short-Cap on the NEMAReceptacle correctly. Install theShort-Cap provided by pressing downand twisting CW.
Note: If Photocell Sensor isprovided see the following forinstructions.
The default settings can be changed by adjusting the DIP Switches on the MotionSensor. Please refer to the table on this page and also directly on the Motion Sensor.
Turn over the FALC Fixture showing the Lens side. Remove the Screws (4) fromthe Shell Cover. Then remove the Shell Cover from the FALC Fixture. The MotionSensor is now open to adjust (if needed) the setting. The process is the same for allFALC-LV-MS fixtures.
Optional Microwave Motion Sensor(FALC-LV-MS ONLY)
1
2
The Integrated Microwave Motion Sensor is a programmable motion detector. This isonly for the FALC-LV-MS models ONLY. The default factory settings are as follows:Detection Area=100%, Hold Time=5 sec, Stand-By Period=5 sec, Stand-By DimmingLevel=10%, and Daylight (Photo) Sensor=Disable.
Note: If the Microwave Motion Sensor is not included or adjustment is not needed,the following steps can be skipped.
MOTIONSENSOR
DIPSWITCHES
FALC-LVSHELLCOVER
SCREWS
Microwave Motion Sensor DIP Pin Setting
Detection AreaDetection area having motion and not enough ambient light willactivate the sensor. The sensor can be set at 100%, 75%, 50%,or 10%.
Hold TimeHold Time refers to the time period the fixture remains at 100%illumination after motion is detected. Hold Time can range from5s to 20 minutes. The fixture will remain at full illumination until‘Hold Time’ ends, then reducing to Stand-By Dimming Level.
Stand-By PeriodThe Stand-By period begins when the ‘Hold Time’ ends. Thefixture remains at a Stand-By Dimming Level before it completelyswitches off while motion is not present. When set to “+∞” mode,the low led light is held until motion is detected.
Daylight (Photo) SensorThe Daylight Sensor, measured in LUX can be set to allow thefixture to illuminate below a surrounding minimum ambientbrightness threshold. The sensor can be set from 2 to 100 LUX.When set to Disable mode, the Daylight Sensor will switch onthe fixture when motion is detected regardless of ambient light.
Stand-By Dimming LevelStand-By Dimming Level is when ‘Hold Time’ has ended, thereis no movement in the area and the light output is reduced. TheStand-By Dimming Level can be set at 50%, 30%, 20%, or 10%.
By selecting the combination on the DIP switches, sensor data can be preciselyset for each specific application as seen below.
+∞
+∞
SHORT-CAPNEMA
RECEPTACLE
Turn over the FALC Fixture showing the Fin side. All FALC Fixturescome with a NEMA Seven-Prong Twist Lock receptacle (Compatible withThree-Prong Photocell Sensors) with Short-Cap to be installed. Removethe Short-Cap by twisting CCW and lifting.
Optional Photocell SensorThe Photocell Sensor has a Dusk to Dawn functionality. The Photocell Sensor can be easily field installed on all FALC fixtures asshown below. Note: If the Photocell Sensor is not included the following steps can be skipped. If the Photocell Sensor is includedprior to field installation, Step 1 can be skipped.
1 Place the Photocell Sensor on the NEMAreceptacle. Push down and twist CW. Theprocess is the same for all FALC Fixtures.
2
PHOTOCELLSENSOR
NEMARECEPTACLE
NEMA THREE-PRONGTWIST LOCK PLUGSHORT-
CAP
Initial Set-up and Optional Controls
2
9
“Initial Set-up and Optional Controls”
Page 2 of 7
1 All FALC fixtures have one Cable coming from the luminaire. 2
3
Remove the [4] Socket headscrews from the AC-ALC-SF.
Run the FALC Cable from the FALCFixture and the SLIPFITTER MOUNT to thePole and follow the Wiring Diagram providedto properly install the light fixture to thePOWER SUPPLY CABLE. All wiring mustbe installed by a certified electrician andmust be compliant to NEC standards.
5
4
6
If needed to tilt the FALC FIXTURE,loosen the Socket Head Screw tounmate the teeth of the FALCBRACKET MOUNT and theSLIPFITTER .
Align the teeth from the FALC Bracket Mountwith the teeth on the SLIPFITTER. Use Cautionwith the FALC Cable during assembly. Use awrench to install the SOCKET HEAD SCREWand assemble the AC-ALC-SF SLIPFITTER.
7
8 Move the FALC FIXTURE to thedesired tilt angle. Mate the teeth ofthe FALC BRACKET MOUNT andthe SLIPFITTER together. Tightenthe Socket Head Screw with a wrench.
SLIPFITTER
SCREW
FALCFIXTURE
AC-ALC-SF Slipfitter MountAC-ALC-SF Slipfitter Mount
FALC Series LED Area Light Installation Guide
Need help? Tech help line: (800) 988-6386 Email: [email protected] Website: www.paclights.com
Copyright © 2020 PacLights All Rights Reserved 02-00041-20423Note: Instructions are subject to change at any time without notice
Run the FALC CABLE through the inside of the SLIPFITTER and out the end.
FALC CABLE
FALCFIXTURE
FALCBRACKETMOUNT
SLIPFITTER
SCREW
SLIPFITTER
FALC CABLE
FALCBRACKET MOUNT
FALCFIXTURE
SCREW
POLE
FALCFIXTURE
SLIPFITTER
Insert the SLIPFITTER with the FALCFIXTURE onto the Pole and fasten the[4] Socket Head Screws.
FALC CABLE
FALCBRACKET MOUNT
FALC CABLE
POWERSUPPLY CABLE
SLIPFITTER
FALCBRACKET MOUNT
2
9
“Initial Set-up and Optional Controls”
FALC Series LED Area Light Installation Guide
Need help? Tech help line: (800) 988-6386 Email: [email protected] Website: www.paclights.com
Copyright © 2020 PacLights All Rights Reserved Note: Instructions are subject to change at any time without notice 02-00041-20423
AC-ALC-AM can be used on a Round Pole or a Square Pole
DRILLINGTEMPLATE
O 0.69” Run PowerSupply Cable throughthis hole opening intothe Arm Mount
O 0.375” Clearanceholes on pole to alignwith Locking Platehole locations
Drill holes on the square poleby following the Drilling Templateto mount the FALC to the desiredheight.
If the FALC fixture is being installedto a square pole, remove the round polegasket.
Remove the [4] Flat-Head MachineScrews and the Side Plate beforeinstalling into the FALC Fixture.
Run the FALC Cable through theinside the Arm Mount. Align the holeand teeth from the Arm Mount withthe FALC Bracket Mount and use theSocket Head Screw to fasten themtogether at the appropriate Fixture tiltangle.
Run the Power Supply Cable inside the MountingPole through the 3/8” clearance hole and into the ArmMount. Follow the Wiring Diagram to properly connectthe FALC Fixture.
For the Round Pole, repeat Steps1-6 the same asa Square Pole, except the round pole gasket will stillbe attached to the ARM MOUNT.
All wiring must be installed by a certified electricianand must be compliant to NEC standards. Once allwiring is properly installed fasten the SIDE PLATE backto the Arm Mount.
Page 3 of 7
SOCKET HEADSCREW
LOCKWASHERWASHER
LOCKINGPLATE
ROUND POLEGASKET
SQUAREPOLE GASKET
AC-ALC-AMBRACKET
5.5”
6.25”
1.125”
DRILLHOLES
LOCKING PLATE
ROUND POLEGASKET
SOCKET HEADSCREW
1
2
3 4 5
7 8 9
Prior to installing remove the LockingPlate from the Arm Mount by removing theSocket Head Screws. This allows for theparts to be removed as well. Depending onwhether a round pole or square is used willdetermine which parts are needed.
Place the lock plate and gasketinside the Mounting Pole and fastenthe FALC Fixture onto the pole withthe Socket Head Screws removed inStep 2.
6
LOCKINGPLATE
SQUARE POLE GASKET
SCREW
SIDE PLATE
SCREWSSCREW
FALC CABLE
FALCMOUNT
FALCARMMOUNT
SOCKET HEADSCREW
FALC CABLE
POWER SUPPLYCABLE
SIDE PLATESCREWS
ARM MOUNT
MOUNTINGPOLE
POLE
ARM MOUNTMOUNTING
POLE
ROUND POLE SQUARE POLE
Arm Mount (Round or Square Pole)AC-ALC-AM Arm Mount (Round or Square Pole)AC-ALC-AM
2
9
“Initial Set-up and Optional Controls”
FALC Series LED Area Light Installation Guide
Need help? Tech help line: (800) 988-6386 Email: [email protected] Website: www.paclights.com
Copyright © 2020 PacLights All Rights Reserved Note: Instructions are subject to change at any time without notice 02-00041-20423
AC-ALC-TM Trunnion MountAC-ALC-TM Trunnion Mount
DRILLING TEMPLATE
1.516”
1.375”
0.545”
3.031”
O 1.00”
Ø 0.437”
If the Power Supply Cable is coming from the wall, the Power Supply Cable willrun through the center of the Trunnion Mount. Then, mount the Trunnion Mount ontothe Mounting Surface using the appropriate mounting Bolts.
(Optional) This hole is onlynecessary if the power supplycable will be coming out the wall.
Once the FALC Fixture is properlysecured to the Trunnion Mount, adjustthe fixture to the desired tilt angle andfasten the Socket Head Screw.
Align the teeth from theFALC Bracket Mount to theTrunnion Mount. Use theSocket Head Screw to fastenthem together. You canconnect the FALC CABLE tothe Power Supply withoutusing a Junction Box only ifused with a weather proofconnector.
Page 4 of 7
BOLTS
TRUNNIONMOUNT
SOCKET HEADSCREW
2
POWER SUPPLYCABLE
3
5If the Power Supply Cable is ran from a Conduit, the FALC Cable must befed into a Junction Box specific for outdoor applications. All wiring must be doneinside the J-BOX and all cables must be fed through a water proof connector.
4
POWER SUPPLYCABLE
SCREWPOWERSUPPLYCABLE
Clearance holeson Mounting Surface toalign with Trunnion Mounthole locations
MOUNTINGSURFACE
TRUNNIONMOUNT
FALC CABLE
FALCBRACKETMOUNT
FALC CABLE
J-BOX FALC FIXTURE
TRUNNIONMOUNT
Drill holes on theMounting Surface byfollowing the DrillingTemplate to mount theTrunnion Mount to thedesired height.
DRILLHOLES
1
2
9
“Initial Set-up and Optional Controls”
Page 5 of 7
1 All FALC fixtures have one Cable coming from the luminaire. Carefully run thecable through the Universal Mount.
2
3
Remove the [4] Socket Head Screws from theTrunnion Mount.
Insert the Universal Mount onto the Pole andfasten the [4] Socket Head Screws.
5
7 If needed to tilt the FALCFixture loosen the Socket HeadScrew and unmate the teeth ofthe FALC Bracket Mount andthe Universal Mount. Rotatethe FALC Fixture to the desiredtilt angle. Mate the teeth of theFALC Bracket Mount and theUniversal Mount together andfasten the Socket Head Screw.
Use a wrench, to fasten the Socket Head Screw.Use Caution with the FALC Cable during assemblywith the Universal Mount.
8
AC-ALC-3M 3-in-1 Universal Mount(as Slipfitter)AC-ALC-3M 3-in-1 Universal Mount(as Slipfitter)
FALC Series LED Area Light Installation Guide
Need help? Tech help line: (800) 988-6386 Email: [email protected] Website: www.paclights.com
Copyright © 2020 PacLights All Rights Reserved
STANDARD INSTALLATION STEPS
02-00041-20423Note: Instructions are subject to change at any time without notice
Run the FALC CABLE through the Universal Mount and align the teeth from theFALC Bracket Mount with the teeth on the Universal Mount.
FALC CABLE
FALCFIXTURE
FALCBRACKETMOUNT
UNIVERSALMOUNT
UNIVERSALMOUNT
FALCCABLE
FALC BRACKETMOUNT
FALCFIXTURE
SCREW
UNIVERSALMOUNT
FALCFIXTURE
SCREW
Run the FALC Cable to the Power SupplyCable from the Pole and follow the WiringDiagram provided to properly install the FALCFixture. All wiring must be installed by acertified electrician and must be compliant toNEC standards.
SIDEPLATE
SIDE PLATEGASKET SCREWS
Remove the [4] Flat-Head Machine Screws andthe Side Plate before installing onto the Pole to slidethe cables through.
4
6
5
FALCCABLE
SCREW
UNIVERSALMOUNT
FALCCABLE
POWERSUPPLYCABLE
POLE
UNIVERSALMOUNT
FALC BRACKETMOUNT
All wiring must be installed by acertified electrician and must becompliant to NEC standards. Onceall wiring is properly installed fastenthe Side Plate and Gasket back tothe Arm Mount.
9
SCREWS
SIDE PLATEGASKET
ARMMOUNT
2
9
“Initial Set-up and Optional Controls”
FALC Series LED Area Light Installation Guide
Need help? Tech help line: (800) 988-6386 Email: [email protected] Website: www.paclights.com
Copyright © 2020 PacLights All Rights Reserved Note: Instructions are subject to change at any time without notice 02-00041-20423
AC-ALC-3M 3-in-1 Universal Mount(as Arm Mount)AC-ALC-3M 3-in-1 Universal Mount(as Arm Mount)
AC-ALC-3M can be used on a Round Pole or a Square Pole
DRILLINGTEMPLATE
Run Power SupplyCable through thisslot opening intothe Arm Mount
Ø 0.375” Clearanceholes on pole to alignwith Locking Platehole locations
Drill holes on the square poleby following the Drilling Templateto mount the FALC Fixture withthe Universal Arm Mount to thedesired height.
Prior to installing, remove theLocking Plate from the UniversalArm Mount by removing the SocketHead Screws. This allows for theparts to be removed as well.Depending on whether a RoundPole or Square Pole is used willdetermine which parts are needed.
Note: If the FALC Fixture is beinginstalled to a round pole this step canbe skipped. Remove the Round PoleAdapter Plate and Gasket.
Remove the [4] Flat-Head MachineScrews and the Side Plate beforeinstalling into the FALC Fixture.
Run the FALC Cable through theinside of the Arm Mount. Align the holeand teeth from the Arm Mount with theFALC Bracket Mount and use the SocketHead Screw to fasten them together atthe desired FALC Fixture tilt angle.
Place the Locking Plate and Gasketinside the Mounting Pole. Run thePower Supply Cable through the 0.48”clearance Slot and fasten the FALCFixture onto the Mounting Pole with theSocket Head Screws removed in Step 2.
Attach the FALC Cable to the Power Supply Cable.Follow the Wiring Diagram to properly connect the FALCFixture.
For the Round Pole, repeat Steps 1-6 the sameas a Square Pole, except the Round Pole AdapterPlate will still be attached to the Arm Mount.
All wiring must be installed by a certified electricianand must be compliant to NEC standards. Once allwiring is properly installed fasten the Side Plate andGasket back to the Arm Mount.
Page 6 of 7
5.5”
6.25”
0.75”
DRILLHOLES
1
2
3 4 5 6
7 8 9
0.77”
R.24”
ROUND POLEGASKET
ROUND POLEADAPTER
PLATE
SIDEPLATE
SIDEPLATEGASKET
ARMMOUNT
SOCKET HEADSCREW
LOCKINGPLATE
ROUND POLEADAPTER PLATEGASKET
LOCK WASHERWASHER
POLEGASKET
ROUND POLEADAPTER PLATE
LOCKING PLATE
SOCKETHEADSCREW
SCREWS FALC CABLE
SCREWLOCKINGPLATE
POLE GASKET
SCREW
ARM MOUNT
ADAPTER PLATE
ARM MOUNT
SIDE PLATE
SIDE PLATE GASKET
SCREWS
POWER SUPPLYCABLE
UNIVERSAL MOUNT
FALCBRACKETMOUNT
FALC FIXTURE
ARMMOUNT
POLEFALC
POWER SUPPLYCABLE
ROUND POLE SQUARE POLE
2
9
“Initial Set-up and Optional Controls”
FALC Series LED Area Light Installation Guide
Need help? Tech help line: (800) 988-6386 Email: [email protected] Website: www.paclights.com
Copyright © 2020 PacLights All Rights Reserved Note: Instructions are subject to change at any time without notice 02-00041-20423
AC-ALC-3M 3-in-1 Universal Mount(as Trunnion Mount)AC-ALC-3M 3-in-1 Universal Mount(as Trunnion Mount)
Adjust the tilt angle on the FALC Fixture to thedesired location. Tighten the Socket Head Screwswith an wrench to keep the fixture in place.
Drill holes on theMounting Surface byfollowing the DrillingTemplate to mount theTrunnion Mount to thedesired height.
If the Power Supply Cable is coming from a Junction Box theFALC Power Cable must be fed into a Junction Box specific foroutdoor applications. Follow the wiring diagram provided to forinstallation. All wiring must be done inside the J-box and must befed through a water-proof connector. All wiring must be installedby a certified electrician and must be compliant to NEC standards.
Page 7 of 7
SIDE PLATE
SIDEPLATEGASKET
SCREWS
DRILLINGTEMPLATE
Run Power SupplyCable through thisslot opening intothe Arm Mount
Ø 0.375” Clearanceholes on pole to alignwith Locking Platehole locations
5.5”
6.25”
0.75”
0.77”
R.24”
Remove the [4] Flat-Head Machine Screws and the Side Plate before installingonto the FALC Fixture.
If the Power Supply Cableis coming from the wall, the PowerSupply Cable will run through thecenter of the Trunnion Mount.Fasten the Trunnion Mount to theMounting Surface using theappropriate mounting Bolts(not included).
Align the teeth of the FALC Bracket Mountto the Trunnion Mount. Use a wrench to fastenthe Socket Head Srew to the Trunnion Mountand the FALC Bracket Mount. You can connectthe FALC Cable to the Power Supply withoutusing a Junction Box only if used with a weatherproof connector.
Once all wiring is properly installed fastenthe Side Plate and Gasket back to theTrunnion Mount.
DRILLHOLES/SLOT
2
1
3 4
BOLTS
POWERSUPPLYCABLE
TRUNNIONMOUNT
MOUNTINGSURFACE
SCREW
TRUNNIONMOUNT
POWER SUPPLYCABLE
FALCCABLE
5
6
J-BOX
POWER SUPPLY CABLE
FALC CABLE
7
SCREWSSIDE PLATE
SIDEPLATEGASKET
2
9