1 General contents Why use PowerLogic System? 6 IM code 10 Panorama of the PowerLogic range 12 Software general information 17 Examples of architectures 18 Index of catalogue numbers 20 Current transformers 22 CT Panel instruments 28 AMP / VLT IM100 / UM100 FRE CI / CH Kilowatt hour meters 40 ME Power-monitoring units 46 PM9 PM500 PM700 PM800 CM3000 CM4000 Communication and supervision 102 EGX100 EGX400 MPS100 SMS << Back

Upload: buicong

Post on 11-Aug-2018

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

General contents

<< Back

Why use PowerLogic System? 6

IM code 10

Panorama of the PowerLogic range 12

Software general information 17

Examples of architectures 18

Index of catalogue numbers 20

Current transformers 22

CT

Panel instruments 28

AMP / VLT IM100 / UM100 FRE CI / CH

Kilowatt hour meters 40

ME

Power-monitoring units 46

PM9 PM500 PM700 PM800 CM3000 CM4000

Communication and supervision 102

EGX100 EGX400 MPS100 SMS

1

Page 2: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 2 Mardi, 11. avril 2006 4:00 16

0

The Guiding System, the new way to create your electrical installations

A comprehensive offer of products with consistent design

The Guiding System is first and foremost a Merlin Gerin product offer covering all electrical distribution needs. However, what makes all the difference is that these products have been designed to operate togheter: mechanical and electrical compatibility, interoperability, modularity, communication.Thus the electrical installation is both optimised and more efficient: better continuity of supply, enhanced safety for people and equipment, guaranteed upgradeability, effective monitoring and control.

Tools to simplify design and implementation

With the Guiding System, you have a comprehensive range of tools - the Guiding Tools - that will help you increase your product knowledge and product utilisation. Of course this is in compliance with current standards and procedures.These tools include technical booklets and guides, design aid software, training courses, etc. and are regularly updated.

For a genuine partnership with you

Because each electrical installation is unique, there is no standard solution. With the Guiding System, the variety of combinations allows for genuine customisation solutions. You can create and implement electrical installations to meet your creative requirements and design knowledge. You and Merlin Gerin’s Guiding System form a genuine partnership.

For more details on the Guiding System,consult www.merlin-gerin.com

2

Page 3: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 3 Mardi, 11. avril 2006 4:00 16

0

A consistent design of offers from Medium Voltage to Low Voltage

All Merlin Gerin offers are designed according to electrical, mechanical and communication consistency rules.The products express this consistency by their overall design and shared ergonomics.

Electrical consistency:

Each product complies with or enhances system performance at co-ordination level: breaking capacity, Isc, temperature rise, etc. for more safety, continuity of supply (discrimination) or economic optimisation (cascading).The leading edge technologies employed in Merlin Gerin’s Guiding System ensure high performance levels in discrimination and cascading of protection devices, electrodynamic withstand of switches and current distributors, heat loss of devices, distribution blocks and enclosures.Likewise, inter-product ElectroMagnetic Compatibilty (EMC) is guaranteed.

Discrimination guarantees co-ordination between the operating characteristics of serial-connected circuit-breakers. Should a fault occurs downstream, only the circuit-breaker placed immediately upstream from the fault will trip.

Mechanical consistency:

Each product adopts dimensional standards simplifying and optimising its use within the system.It shares the same accessories and auxiliaries and complies with global ergonomic choices (utilisation mode, operating mode, setting and configuration devices, tools, etc.) making its installation and operation within the system a simpler process.

Direct connection of the Canalis KT busbar trunking on the Masterpact 3200 A circuit breaker.

Communication consistency:

Each product complies with global choices in terms of communication protocols (Modbus, Ethernet, etc.) for simplified integration in the management, supervision and monitoring systems.

Thanks to the use of standard Web technologies, you can offer your customers intelligent Merlin Gerin switchboards allowing easy access to information: follow-up of currents, voltages, powers, consumption history, etc.

Guiding Tools for more efficient design and implementation of your installations.

3

Page 4: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 4 Mardi, 11. avril 2006 4:00 16

0

SM6

Medium voltage switchboard system from 1 to 36 kV

Sepam

Protection relays

Masterpact

Protection switchgear from 100 to 6300 A

TrihalMV/LV dry cast resin transformer from 160 to 5000 kVA

EvolisMV vacuum switchgear and components from 1 to 24 kV.

The Technical guide

These technical guides help you comply with installation standards and rules i.e.:The electrical installation guide, the protection guide, the switchboard implementation guide, the technical booklets and the co-ordination tables all form genuine reference tools for the design of high-performance electrical installations.For example, the LV protection co-ordination guide - discrimination and cascading - optimises choice of protection and connection devices while also increasing markedly continuity of supply in the installations.

CAD software and tools

The CAD software and tools enhance productivity and safety.They help you create your installations by simplifying product choice through easy browsing in the Guiding System offers.Last but not least, they optimise use of our products while also complying with standards and proper procedures.

4

Page 5: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 5 Mardi, 11. avril 2006 4:00 16

0

Compact

Protection switchgear system from 100 to 630 A

Multi 9

Modular protection switchgear system up to 125 A

Prisma Plus

Functional system for electrical distribution switchboards up to 3200 A

Pragma CanalisEnclosures for distribution switchboards up to 160 A

Prefabricated Busbar Trunking from 25 to 4000 A

PowerLogicPowermanagement

Training

Training allows you to acquire the Merlin Gerin expertise (installation design, work with power on, etc.) for increased efficiency and a guarantee of improved customer service.The training catalogue includes beginner’s courses in electrical distribution, knowledge of MV and LV switchgear, operation and maintenance of installations, design of LV installations to give but a few examples.

merlin-gerin.com

This international site allows you to access all the Merlin Gerin products in just 2 clicks via comprehensive range data-sheets, with direct links to:b complete library: technical documents, catalogs, FAQs, brochures…b selection guides from the e-catalogb product discovery sites and their Flash animations.You will also find illustrated overviews, news to which you can subscribe, the list of country contacts…

5

Page 6: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16
Page 7: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 7 Mardi, 11. avril 2006 4:00 16

Presentation Why use PowerLogic System? 0

(cont.)

-

PowerLogic System, the key to improving your electrical distribution systemPowerLogic System serves 3 functions:b collection of measurement datab organisation and transmission of measurement data to facilitate analysis by the different departments concerned: production, maintenance, accounting, site managementb checking of the results obtained after implementing electrical distribution system improvement solutions.

DB

1035

69

DB

1034

45

With PowerLogic System,you control your electrical installationPowerLogic System helps you

Reduce energy costsGet a clearer view of your consumptionb identification of major consumers and allocation of costsb management of consumption peaks and optimisation of your utility contract.

Improve continuity of service Use the full capacity or your installationb analysis of the electrical distribution systemb diagnosis of failures.

Improve power quality Increase power-system reliability and optimise your operating costsb monitoring of harmonicsb lower maintenance costsb reduced production losses.

Organisemeasurement data

Collect measurement data

Improve the distribution system

Communication

Devices

Check

Implementsolutions Design/

solutions

Analysis

Remotemonitoring

Continuity of service

Power quality

Energycosts

7

Page 8: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 8 Mardi, 11. avril 2006 4:00 16

Presentation Why use PowerLogic System?Benefits and applications

Reduce energy costs

DB

1034

46

PowerLogic System helps you reduce power consumption and the cost of the energy you use through sub-billing and electrical contract optimisation.

EB

1002

56

Sub-billing and cost allocation to reduce consumptionMetering of energy consumption to:b identify major consumersb allocate costsb make users aware of expenditures.

Optimisation of power contract and load curvesto reduce energy costsRecording of energy consumption and load curves to:b optimise the power contractb aggregate multi-site costs and negotiate global contractsb identify spare capacity for electrical installation extensionsb manage peaks and avoid penalties:v improve power factor by power factor correction solutionsv avoid subscribed-power overruns by automatic load-shedding.

Monitoring of other utilitiesCount pulses received from other utility meters (water, gas, steam, etc.) for global, centralised utility management.

Cost reporting

EB

1002

57

Trend curves

Improve continuity of service

DB

1033

47

Electricity is vital to site operation. However, the phenomena that cause faults are not always easy to understand.PowerLogic System gives a better understanding of the electrical distribution system and offers tools for analysis. It lets you manage the system in real time and thereby increase reliability.

PE

5053

8

Real time monitoring of your electrical installationPanel instrumentationFor local display of measurement data and checks on installation operation.

Remote monitoring Monitoring of the electrical installation to get the right information to the right person at the right time: b switchgear status and measurements for the facility managerb alarms and events for the maintenance departmentb cost allocation for the accounting department, etc.Open, flexible communication system allowing intervention by an external expert when required.

Transparent access to information via Web technologiesWith the EGX400 Web server, you can now access all the information you need wherever you are and whenever you want via a standard browser like Internet Explorer©.

EB

1002

58

Real time monitoring of your electrical installation

8

Page 9: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 9 Mardi, 11. avril 2006 4:00 16

Presentation Why use PowerLogic System?Benefits and applications (cont.)

EB

1002

59

Preventive and corrective maintenancePreventive maintenanceDetection of problems in advance based on key parameters, to avoid equipment failures and downtime.

Corrective maintenanceClear, complete information for the facility manager regarding fault circumstances in order to get power restored as quickly as possible:b local or remote alarms (e.g. by telephone or pager)b fault locating, overall vision, summary tables, etc.

Detailed information for experts in charge of analysing the causes of faults and designing solutions to improve the electrical distribution system:b event and alarm logsb waveform capture, etc.

Event and alarm logs

Improve power quality

DB

1034

48

Power quality has a direct impact on operating costs:b direct costs: over-consumption due to increased power losses b indirect costs: v production losses: process malfunctions, unnecessary trippingv equipment costs: shorter service life, lower efficiency, oversized equipment.

EB

1002

61

PowerLogic System lets you assess the quality of your power, identify the causes of any problems and check the effectiveness of remedial measures.

Four main functions are used to check power quality: b monitoring of harmonicsb detection of voltage sags and swellsb detection of transientsb EN 50160 electricity supply compliance checking.

Measurement of total harmonic distortion and individual harmonic contentb identify sources of harmonic distortion and separate them from sensitive loadsb determine causes of malfunctionsb derate power devices (transformers, cables, etc.)b implement filtering solutions.

Detection and waveform capture of voltage sags and swellsDetermine the origin of production losses or shutdowns.

Detection and waveform capture of transientsDetermine the causes of malfunctions and breakdowns.

EN 50160 electricity supply compliance checkingTo assess the quality of distributed power according to the European standard EN 50160 and check that the distributor complies with the standard.

Spectral analysis of harmonics

EB

1002

60

Disturbance capture

9

Page 10: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 10 Mardi, 11. avril 2006 4:00 16

Product selection guide IM code 0

Select your power-monitoring units the easy way

The IM code (1), a recognised tool

EB

1002

54

PB

1018

08a

The IM code has been developed by Gimélec experts for electrical installation designers and end-users.It is widely used and recognised by the profession, just like the IP code for electrical enclosures or the IS code for electrical switchboards.

An indispensable tool to define and specify the power-monitoring units of your electrical installation

The IM code has 3 functionsb It helps you define your measurement needs for the following applications:v Cost managementv Installation monitoringv Power quality monitoring.

b It determines the most suitable power-monitoring unit.

b It generates specifications for your measurement solution, ensuring supply of the necessary functions and compliance with applicable standards.

Example:

DB

1098

38

A 3-digit codeThe IM code is made up of 3 digits that define the functionality level of a measurement device for one of the 3 applications considered. Each digit varies from 0 to 7, where 7 corresponds to the highest functionality level.

The first digit corresponds to cost management needs. b Optimisation of electrical consumptionb Reduction of electricity billsb Cost allocationb Sub-billing.

The second digit corresponds to electrical installation monitoring needs. b Verification of correct operation of the installationb Verification that the installation is correctly sizedb Monitoring of any drift with respect to nominal conditions.

The third digit corresponds to power quality monitoring needs. b Verification of the quality of power supplied by the distribution utilityb Verification of the quality of power within the installation.

PB

1003

13 -

DB

1098

39

PowerLogic, a comprehensive range of power-monitoring unitsPowerLogic power-monitoring units meet all your energy management needs, from the simplest to the most demanding. They have been designed to provide the optimum solution for the most commonly encountered situations and IM codes.

The table on next page presents the IM codes of the power-monitoring units recommended according to:b building type (tertiary, industrial, etc.)b target application (cost management, installation monitoring, etc.)b the position of the power-monitoring unit (main LV or subdistribution board, incomer or feeder).

(1) The IM code is a Gimélec Promotion registered trademark. The IM software was developed by the Gimélec experts..

Cost management

Installation monitoring

Power quality monitoring

10

Page 11: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 11 Mardi, 11. avril 2006 4:00 16

Product selection guide IM code 0

Select your power-monitoring units the easy way (cont.)

Preferred IM codes

Segments

Applicatifve profile Commercial buildings Industrial buildings Large sites / Infrastructures

Cost management Incomer or feeder:b basic level: 100b medium level: 510b advanced level: 772

Incomer or feeder:b basic level: 100b medium level: 521b advanced level: 772

Incomer or feeder:b basic level: 100b medium level: 641b advanced level: 772

Cost managementInstallation monitoringPQ monitoring (basic)

Main panel board:b incomer: 772b feeder: 641 + time stamping or 772

Main panel board:b incomer: 772b feeder: 641 + time stamping or 772

Main panel board:b incomer: 772b feeder: 641 + time stamping or 772

Secondary panel board: b incomer: 521b feeder: 510 or 521

Secondary panel board: b incomer: 641 + time stampingb feeder: 521

Secondary panel board: b incomer: 641 + time stamping or 772b feeder: 521 or 641 + time stamping

Cost managementInstallation monitoringPQ monitoring (advanced)

b Connecting point: 774 or 777

Main panel board:b incomer: 774 or 777b feeder: 641 + time stamping or 772

Main panel board:b incomer: 772 or 774b feeder: 641 + time stamping or 772

Main panel board:b incomer: 772 or 774b feeder: 641 + time stamping or 772

Secondary panel board: b incomer: 641 + time stamping b feeder: 510 or 521

Secondary panel board: b incomer: 641 + time stamping or 772b feeder: 521

Secondary panel board: b incomer: 772b feeder: 641 + time stamping or 772

most frequent profile

2nd possible profile

3rd possible profile

11

Page 12: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 12 Mardi, 11. avril 2006 4:00 16

Product selection guide Panorama of the PowerLogic range 0

Current transformers Panel instruments

CT Name AMP / VLT AMP / VLTcurrent transformer Function ammeter, voltmeter ammeter, voltmeter

IM code

Installationb insulated cable,diameter 21 to 35 mm,through transformerb busbar through transformerb cable connections

ApplicationsSub-billing and cost allocationEnergy consumption

Consumption for different time periods

Consumption of other utilities

Optimisation of power contract and load curves

Installation monitoring Panel instrumentation I / U I / U

Remote monitoring

Advanced remote monitoring

Power quality analysisMonitoring of harmonics (THD)

Analysis of individual harmonic content

Detection of voltage sags and swells

EN 50160 compliance checking

Characteristics Characteristicsb transformation ratio:40/5 A to 6000/5 Ab accuracy: class 0.5 to 3b maximum rated operational voltage:720 V ACb standard or tropicalised

Measurement accuracy class 1.5 ± 0.5% ± 1 digit

Installation DIN rail4 x 18 mm modules

DIN rail2 x 18 mm modules

Voltage measurement VLT: 500 V AC director external VT

VLT:600 V AC direct or external VT

Current measurement AMP: 30 A director external CT

AMP: 10 A director external CT

Communication ports

Inputs / Outputs

Memory capacity

page 22 page 28 page 29

12

Page 13: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 13 Mardi, 11. avril 2006 4:00 16

Product selection guide Panorama of the PowerLogic range (cont.) 0

Kilowatt hour meters

AMP / VLT IM100 / UM100 FRE CH / CI ME

ammeter, voltmeter ammeter, voltmeter frequency meter hour counterpulse counter

watt-hour meter

I / U I / U F hours / pulses E

class 1.5 ± 1% ± 1 digit ± 0.5% ± 1 digit class 2

flush mount72 x 72 mm96 x 96 mm

flush mount72 x 72 mm

DIN rail2 x 18 mm modules

CI, CH: DIN rail2 x 18 mm modulesCH: flush mount

DIN rail 2 or 4 x 18 mm modules

VLT: 500 V AC direct or external VT

UM100: 600 V AC direct or external VT

400 V AC direct 400 V AC direct

AMP: external CT

IM100:external CT

63 A director external CT

page 30 page 32 page 29 page 36 page 40

13

Page 14: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 14 Mardi, 11. avril 2006 4:00 16

Product selection guide Panorama of the PowerLogic range (cont.) 0

Power-monitoring units

Name PM9 / PM9P / PM9C PM500 PM700 / PM700P /PM710

Function Power Meter Power Meter Power Meter

IM code

ApplicationsSub-billing and cost allocation Energy consumption

Consumption for different time periods

Consumption of other utilities

Optimisation of power contract and load curves

Installation monitoringPanel instrumentation

Remote monitoring

Advanced remote monitoring

Power quality analysisMonitoring of harmonics (THD)

Analysis of individual harmonic content

Detection of voltage sags and swells

EN 50160 compliance checking

CharacteristicsMeasurement accuracy class 2

(active energy)class 1(active energy)

class 1(active energy)

Installation DIN rail4 x 18 mm modules

flush mount96 x 96 mm

flush mount96 x 96 mm

Voltage measurement 450 V ACdirector external VT

480 V ACdirector external VT

480 V ACdirector external VT

Current measurement external CT external CT external CT

Communication ports 1 1 1

Inputs / Outputs 1 O 8 I/O 2 O

Memory capacity

page 50 page 56 page 62

14

Page 15: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 15 Mardi, 11. avril 2006 4:00 16

Product selection guide Panorama of the PowerLogic range (cont.) 0

PM810 PM820 / PM850 PM870 CM3000 CM4000Power Meter Power Meter Power Meter Power Meter Power Meter

time-stamped alarms time-stamped alarms… …and data logs

class 0.5S(active energy)

class 0.5S(active energy)

class 0.5S(active energy)

class 0.5S(active energy)

class 0.2S(active energy)

flush mount96 x 96 mm

flush mount96 x 96 mm

flush mount96 x 96 mm

display in front,module inside switchboard

display in front,module inside switchboard

600 V ACdirector external VT

600 V ACdirector external VT

600 V ACdirector external VT

600 V ACdirector external VT

600 V ACdirector external VT

external CT external CT external CT external CT external CT

1 1 1 4 5

16 I/O 16 I/O 16 I/O 9 I/O 25 I/O

80 / 800 kbytes 80 / 800 kbytes 8 Mbytes 32 Mbytes

page 68 page 80 page 90

15

Page 16: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 16 Mardi, 11. avril 2006 4:00 16

Product selection guide Panorama of the PowerLogic range (cont.) 0

Communication and supervision

Name EGX100 EGX400 MPS100 SMS

Function Ethernet gateway

Ethernet server

Ethernet server

power-monitoring software

ApplicationsEthernet communicationRS485 / Ethernet gateway

Web server withstandard HTML pages

Micrologic, PM9C, PM500, PM710, PM800, SepamCM3000, CM4000

Micrologic, PM9C, PM500, PM710, PM800, SepamCM3000, CM4000

Micrologic, PM9C, PM500, PM710, PM800, SepamCM3000, CM4000

Web server withcustom HTML pages

Remote monitoringReal time data

Historical data

Automatic notification

Alarm and event logs

Waveform display

Custom animated graphics

Automatic creation of custom reports

CharacteristicsEthernet portsModbus TCP / IP protocol

10/100 Base TX port 10/100 Base TX port+ 100 Base FX port(fiber optics)

10 Base TX port

RS485 (2-wire / 4-wire) portsModbus protocol

2 2 1

Number of devices connected directly 64 64 10

RS232 configuration ports 1 1 1

Miscellaneous b 1 modem portb SMTP clientb 6 I / 2 O

Installation DIN rail DIN rail ordesktop

DIN rail ordesktop

page 104 page 110 page 112

16

Page 17: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 17 Mardi, 11. avril 2006 4:00 16

Product selection guide General information on power-monitoring software 0

Software, a tool serving site operation.A site can be compared to a living organism.The power system manger has no control over the changes that affect this organism, but must ensure that it continues to receive the energy it requires.Similar to a doctor, the power system manager must carry out preventive measures and diagnose and remedy any problems that occur. The goal is to maintain the site in a healthy state, without generating any secondary effects.Software enables managers to diagnose the causes of most problems encountered on electrical systems.

More and more devices are capable of communicating.The number of available measurements is also on the rise, creating the need for a tool to successfully manage all the information..

The main purpose of software is to simplify complex sites so that they can be managed by humans:b make the site and its operation intelligibleb make the power system tangible and visible.

The role of softwareAll measurements at a single locationAll measured values may be accessed via a PC.

Organisation and use of measurementsBefore they may be used, certain measurements must be organised, processed or integrated in special tools.

Device setup, example of a Circuit MonitorSimple devices may be set up on their front panels.For devices with advanced functions, local setup is often difficult and even impossible for some functions.Software greatly facilitates device setup.

Automatic tasksSoftware can execute tasks automatically, triggered by:b a dateb an eventb an alarm.These tasks may concern devices (reset, start of a particular function) or system users (transmission of an e-mail, etc.).

Manual commandsPower-monitoring software can also be used to control devices (e.g. open or close a circuit breaker).Certain control/monitoring functions (automatic action on electrical-distribution system) are carried out by PLCs integrated in the PowerLogic System architecture.

Access via the WebInformation must be adapted to user needs and then made available to them.Software can handle the adaptation by preparing custom reports.These reports can then be accessed by any PC on the site using a standard Web browser.

Software and architectureSoftware must be capable of meeting a large number of needs:b single-user or multi-user operationb data organisation according to user profilesb adaptation to different site topologiesb data exchange with other systemsb etc.This set of constraints means that a single product is not sufficient; a range of software products is required..

EB

1002

62

17

Page 18: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 18 Mardi, 11. avril 2006 4:00 16

Product selection guide Examples of architectures 0

PowerLogic System can be used in a number of different architectures depending on the layout of the site. It also offers different user profiles simultaneously.

Example 1b installation in a small building or isolated equipment roomb one or more metering/monitoring units connected to a simple PC (directly or via modem)b for electrical installation monitoring by the maintenance department.

DB

1098

49

Example 2 b installation in a building with a number of users interconnected by a local Intranetb connection of metering/monitoring units to EGX gateways for integration in the company Ethernet networkb for shared management of the electrical installation by different departments: v simple monitoring, with no dedicated software, using a Web browser, v complete power-monitoring using SMS software.

DB

1098

50

Modbus RS485

Webbrowser

SMS

Ethernet TCP/IP

Modbus RS485 Modbus RS485

18

Page 19: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 19 Mardi, 11. avril 2006 4:00 16

Product selection guide Examples of architectures (cont.) 0

Example 3b installation in a number of buildings linked by a company Intranetb connection of metering/monitoring units to EGX Web servers for integration in the company Ethernet networkb all sectors of the company connected to the Intranet have direct access to essential data on the electrical installation via their Web browser.

DB

1098

51

Intranet

Modbus RS485 Modbus RS485

Webbrowser

SMS

Ethernet TCP/IP

19

Page 20: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

Index of catalogue numbers

ART10934.book Page 20 Mardi, 11. avril 2006 4:00 16

Cat. no. Description Page

1510015125 CMV voltmeter selector switch, DIN rail 3415126 CMA ammeter selector, DIN rail 34

15197 Power Meter PM9P (220 to 240 V AC) 5015198 Power Meter PM9C (220 to 240 V AC) 5015199 Power Meter PM9 (220 to 240 V AC) 50

1520015201 VLT digital voltmeter, DIN rail 2915202 AMP direct reading digital ammeter, DIN rail 2915208 FRE digital frequency meter, DIN rail 29

15209 AMP multi-rating digital ammeter, DIN rail 2915274 Power Meter PM9 (24 to 48 V DC) 50

15275 Power Meter PM9P (24 to 48 V DC) 5015276 Power Meter PM9C (24 to 48 V DC) 50

1540015440 CH hour counter, DIN rail (230 V AC) 36

15443 CI impulse counter, DIN rail 37

1560015607 CH hour counter, 48 x 48 (24 V AC) 3615608 CH hour counter, 48 x 48 (230 V AC) 36

15609 CH hour counter, 48 x 48 (12 to 36 V DC) 36

1600016003 AMP analog ammeter, 72 x 72, for motor feeders

(delivered without dial)30

16004 AMP analog ammeter, 72 x 72, for standard feeders (delivered without dial)

30

16005 VLT analog voltmeter, 72 x 72 3016006 Dial, 0-30-90 A, for AMP 16003 30

16007 Dial, 0-75-225 A, for AMP 16003 3016008 Dial, 0-200-600 A, for AMP 16003 3016009 Dial, 0-50 A, for AMP 16004 30

16010 Dial, 0-100 A, for AMP 16004 3016011 Dial, 0-200 A, for AMP 16004 3016012 Dial, 0-400 A, for AMP 16004 30

16013 Dial, 0-600 A, for AMP 16004 3016014 Dial, 0-1000 A, for AMP 16004 3016015 Dial, 0-1250 A, for AMP 16004 30

16016 Dial, 0-1500 A, for AMP 16004 3016017 CMA ammeter selector switch, 48 x 48 3516018 CMV voltmeter selector switch, 48 x 48 35

16019 Dial, 0-2000 A, for AMP 16004 3016029 AMP analog ammeter for direct connection, DIN rail 2816030 AMP analog ammeter for connection to TC (delivered

without dial), DIN rail28

16031 Dial, 0-5 A, for AMP 16030 28

16032 Dial, 0-50 A, for AMP 16030 2816033 Dial, 0-75 A, for AMP 16030 2816034 Dial, 0-100 A, for AMP 16030 28

16035 Dial, 0-150 A, for AMP 16030 2816036 Dial, 0-200 A, for AMP 16030 2816037 Dial, 0-250 A, for AMP 16030 28

16038 Dial, 0-300 A, for AMP 16030 2816039 Dial, 0-400 A, for AMP 16030 2816040 Dial, 0-500 A, for AMP 16030 28

16041 Dial, 0-600 A, for AMP 16030 2816042 Dial, 0-800 A, for AMP 16030 2816043 Dial, 0-1000 A, for AMP 16030 28

16044 Dial, 0-1500 A, for AMP 16030 2816045 Dial, 0-2000 A, for AMP 16030 2816060 VLT analog voltmeter (0-300 V), DIN rail 28

16061 VLT analog voltmeter (0-500 V), DIN rail 2816073 AMP analog ammeter, 96 x 96, for motor feeder

(delivered without dial)31

16074 AMP analog ammeter, 96 x 96, for standard feeder (delivered without dial)

31

16075 VLT analog voltmeter, 96 x 96 3116076 Dial, 0-30-90 A, for AMP 16073 31

16077 Dial, 0-75-225 A, for AMP 16073 31

20

Cat. no. Description Page16078 Dial, 0-200-600 A, for AMP 16073 31

16079 Dial, 0-50 A, for AMP 16074 3116080 Dial, 0-100 A, for AMP 16074 3116081 Dial, 0-200 A, for AMP 16074 31

16082 Dial, 0-400 A, for AMP 16074 3116083 Dial, 0-600 A, for AMP 16074 3116084 Dial, 0-1000 A, for AMP 16074 31

16085 Dial, 0-1250 A, for AMP 16074 3116086 Dial, 0-1500 A, for AMP 16074 3116087 Dial, 0-2000 A, for AMP 16074 31

16088 Dial, 0-2500 A, for AMP 16074 3116089 Dial, 0-3000 A, for AMP 16074 3116090 Dial, 0-4000 A, for AMP 16074 31

16091 Dial, 0-5000 A, for AMP 16074 3116092 Dial, 0-6000 A, for AMP 16074 31

1640016451 TC 50/5 tropicalised transformer for cables 23

16452 TC 75/5 tropicalised transformer for cables 2316453 TC 100/5 tropicalised transformer for cables 2316454 TC 125/5 tropicalised transformer for cables 23

16455 TC 150/5 tropicalised transformer for cables 2316456 TC 200/5 tropicalised transformer for cables 23

16459 TC 150/5 tropicalised transfo. for cables and busbars 2316460 TC 200/5 tropicalised transfo. for cables and busbars 2316461 TC 250/5 tropicalised transfo. for cables and busbars 23

16462 TC 300/5 tropicalised transformer for cables 2316463 TC 400/5 tropicalised transfo. for cables and busbars 2316464 TC 500/5 tropicalised transfo. for cables and busbars 23

16465 TC 600/5 tropicalised transfo. for cables and busbars 2316468 TC 250/5 tropicalised transfo. for cables and busbars 2316469 TC 300/5 tropicalised transfo. for cables and busbars 23

16470 TC 400/5 tropicalised transfo. for cables and busbars 2316471 TC 500/5 tropicalised transfo. for cables and busbars 2316473 TC 500/5 tropicalised transformer for busbars 23

16474 TC 600/5 tropicalised transformer for busbars 2316476 TC 200/5 tropicalised transformer for busbars 2316477 TC 250/5 tropicalised transformer for busbars 23

16478 TC 300/5 tropicalised transformer for busbars 2316479 TC 400/5 tropicalised transformer for busbars 2316480 TC 500/5 tropicalised transformer for busbars 23

16481 TC 600/5 tropicalised transformer for busbars 2316482 TC 800/5 tropicalised transformer for busbars 2316483 TC 1000/5 tropicalised transformer for busbars 23

1650016500 TC 40/5 tropicalised transformer for cables 2316501 TC 50/5 tropicalised transformer for cables 2316502 TC 75/5 tropicalised transformer for cables 23

16503 TC 100/5 tropicalised transformer for cables 2316504 TC 125/5 standard transformer for cables 2316505 TC 150/5 standard transformer for cables 23

16506 TC 200/5 standard transformer for cables 2316509 TC 150/5 standard transfo. for cables and busbars 2316510 TC 200/5 standard transfo. for cables and busbars 23

16511 TC 250/5 standard transfo. for cables and busbars 2316512 TC 300/5 standard transfo. for cables and busbars 2316513 TC 400/5 standard transfo. for cables and busbars 23

16514 TC 500/5 standard transfo. for cables and busbars 2316515 TC 600/5 standard transfo. for cables and busbars 2316518 TC 250/5 standard transfo. for cables and busbars 23

16519 TC 300/5 standard transfo. for cables and busbars 2316520 TC 400/5 standard transfo. for cables and busbars 2316521 TC 500/5 standard transfo. for cables and busbars 23

16523 TC 500/5 standard transformer for busbars 2316524 TC 600/5 standard transformer for busbars 2316526 TC 200/5 standard transformer for busbars 23

16527 TC 250/5 standard transformer for busbars 2316528 TC 300/5 standard transformer for busbars 2316529 TC 400/5 standard transformer for busbars 23

Page 21: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

Index of catalogue numbers (cont.)

ART10934.book Page 21 Mardi, 11. avril 2006 4:00 16

Cat. no. Description Page Cat. no. Description Page16530 TC 500/5 standard transformer for busbars 23

16531 TC 600/5 standard transformer for busbars 2316532 TC 800/5 standard transformer for busbars 2316533 TC 1000/5 standard transformer for busbars 23

16534 TC 1250/5 tropicalised transformer for busbars 2316535 TC 1500/5 tropicalised transformer for busbars 2316537 TC 1250/5 tropicalised transformer for busbars 23

16538 TC 1500/5 tropicalised transformer for busbars 2316540 TC 1250/5 tropicalised transformer for busbars 2316541 TC 1500/5 tropicalised transformer for busbars 23

16542 TC 2000/5 tropicalised transformer for busbars 2316543 TC 2500/5 tropicalised transformer for busbars 2316544 TC 3000/5 tropicalised transformer for busbars 23

16545 TC 2500/5 tropicalised transformer for busbars 2316546 TC 3000/5 tropicalised transformer for busbars 2316547 TC 4000/5 tropicalised transformer for busbars 23

16548 TC 5000/5 tropicalised transformer for busbars 2316549 TC 6000/5 tropicalised transformer for busbars 2316550 Cylinder Ø 8.5 mm for TC transformer 23

16551 Cylinder Ø 12.5 mm for TC transformer 2316552 Lead-sealable cover for TC transformer 2316553 Lead-sealable cover for TC transformer 23

1700017065 ME1 digital watt-hour meter 4017066 ME1z digital watt-hour meter 40

17067 ME1zr digital watt-hour meter 4017070 ME4 digital watt-hour meter 4017071 ME4zr digital watt-hour meter 40

17072 ME4zrt digital watt-hour meter 4017075 ME3 digital watt-hour meter 4017076 ME3zr digital watt-hour meter 40

3350033507 MPS100 Micro Power Server 111

5080050831 UM100 digital voltmeter, 72 x 72 (48 to 115 V AC/DC) 3350832 UM100 digital voltmeter, 72 x 72 (220 to 240 V AC) 33

50834 UM100 digital voltmeter, 72 x 72 (380 to 415 V AC) 3350835 IM100 digital ammeter, 72 x 72 (48 to 115 V AC/DC) 3250836 IM100 digital ammeter, 72 x 72 (220 to 240 V AC) 32

50837 IM100 digital ammeter, 72 x 72 (380 to 415 V AC) 32

5090050980 Power Meter PM500 (AC/DC) 5650981 Power Meter PM500 (24 to 48 V DC) 56

50982 Modbus RS485 module for PM500 5650983 IO11 Puls module for PM500 5650984 IO22 Alarm module for PM500 56

50985 AO20 4-20 mA module for PM500 5650986 IO02 2 Puls module for PM500 56

AAI05 AI05 module for CM Series 4000 95

AI420 AI420 module for CM Series 4000 95AO420 AO420 module for CM Series 4000 95

CCAB4 PM/CM <-> display connection cable (1.25 m) 69,

82, 92CAB12 PM/CM <-> display connection cable (3.65 m) 69,

82, 92CAB30 PM/CM <-> display connection cable (9.14 m) 69,

82, 92CM3250MG Circuit Monitor CM3250 80

CM3350MG Circuit Monitor CM3350 80CM4000TMG Circuit Monitor CM4000T 91CM4250MG Circuit Monitor CM4250 91

CM4MEM16M Memory extension kit for CM Series 4000, 16 Mb 93CM4MEM32M Memory extension kit for CM Series 4000, 32 Mb 93CMDLCMG CMDLC LCD display for CM Series 3000/4000 82, 92

CMDVFMG CMDVF vacuum fluorescent displayfor CM Series 3000/4000

82, 92

CVM42 CVM42 current/voltage module for CM4250 93

CVMT CVMT current/voltage module for CM4000T 93

DDI120AC DI120AC module for CM Series 4000 95DI240AC DI240AC module for CM Series 4000 95

DI32DC DI32DC module for CM Series 4000 95DO120AC DO120AC module for CM Series 4000 95DO200DC DO200DC module for CM Series 4000 95

DO240AC DO240AC module for CM Series 4000 95DO60DC DO60DC module for CM Series 4000 95

EECC21 Ethernet ECC21 communication card

for CM Series 3000/400083, 93

EGX100MG EGX100 Ethernet gateway 104

EGX400MG EGX400 Ethernet server 105

GGFXv4 Web-based interactive graphics add-on for SMS 4.0 112

IIOC44 IOC44 card for CM Series 3000/4000 83, 94

IOX IOX extender for CM Series 4000 94IOX0404 IOX0404 extender for CM Series 4000 94IOX08 IOX08 extender for CM Series 4000 94

IOX2411 IOX2411 extender for CM Series 4000 94

OOCIVF OCIVF optical communication interface (CMDVF/PC) 82, 92

PPM700MG PM700 Power Meter 62PM700PMG PM700P Power Meter 62PM710MG PM710 Power Meter 62

PM810LOG Optional logging module for on-board data recording for PM810

69

PM810MG PM810 Power Meter with integrated display 69PM810RDMG Meter and remote display kit 69PM810UMG PM810 Power Meter without display 69

PM820MG PM820 Power Meter with integrated display 69PM820RDMG Meter and remote display kit 69PM820UMG PM820 Power Meter without display 69

PM850MG PM850 Power Meter with integrated display 69PM850RDMG Meter and remote display kit 69PM850UMG PM850 Power Meter without display 69

PM870MG PM870 Power Meter with integrated display 69PM870RDMG Meter and remote display kit 69PM870UMG PM870 Power Meter without display 69

PM8M22 PM8M22 module for PM Series 800 69PM8M2222 PM8M2222 module for PM Series 800 69PM8M26 PM8M26 module for PM Series 800 69

PM8RDA Remote display adapter only 69PM8RDMG Remote display and adapter with a 3.55 m cable 69

RRJ11EXT RJ11 Extender kit to mount RJ11 jack in panel door 69

SSMSADVRPTS Advanced reports add-on for SMSSE 112SMSDL System Manager DL 4.0 112SMSDL2SE Converts SMSDL to SMSSE 112

SMSDL32U Extends SMSDL device limit to 32 112SMSOPC OPC server application for SMS 4.0 112SMSPE System Manager Professional 4.0 112

SMSRX Enterprise receive add-on for SMS-3000 112SMSSE System Manager Standard 4.0 112SMSSE2PE Converts SMSSE to SMSPE 112

SMSWebXTR 5 additional Web client connections to SMSDL, SMSSE and SMSPE

112

21

Page 22: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

92068E_Ver4.0.fm Page 22 Jeudi, 13. avril 2006 2:46 14

Current transformers CT current transformers 0

FunctionThe Ip/5A ratio current transformers deliver at the secondary a current of 0 to 5 A that is proportional to the current measured at the primary. They are available in two major families:b cable current transformersb bar current transformers.This allows them to be used in combination with measurement instruments: ammeters, watt-hour meters, measurement units, control relays, etc.

Common technical datab Secondary current: 5 Ab Max. voltage rating Ue: 720 Vb Frequency: 50/60 Hzb Safety factor (sf):v 40 to 4,000 A : sf y 5v 5,000 to 6,000 A : sf y 10.b Degree of protection: IP20b Operating temperature:v standard range: -5°C to +55°C, humidity < 95%v tropicalised range: -25°C to +60°C, relative humidity > 95%b Compliance with standards: IEC 60044-1 and VDE 0414b Secondary connection (as per model):v by terminals for lugv by tunnel terminalsv by screws.

Connection

0568

53N

MD

-2

16503.

0568

54N

MD

-2

16512.

0568

52N

MD

-2

16542.

PB

1003

16

16503 + 16550.

0568

55M

D-2

Sealable cover.

E56

648

E56

651

CT with let-through primary.

E56

646

E56

647

CT with primary connection by screw and nut.Use of cylinder 16550 or 16551.

K

S1S2

P1K

L

K

P2

K

S1S2

P1K

L K

S1S2

P1K

L

22

Page 23: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

92068E_Ver4.0.fm Page 23 Jeudi, 13. avril 2006 2:46 14

Current transformers CT current transformers (cont.) 0

Catalogue numbers

(1) Cable(s) that can be routed through the CT(2) For CT with primary connection by screw and nut.(3) Cylinder with inner dia. 8.5 mm, L = 32 mm(4) Cylinder with inner dia. 12.5 mm, L = 62 mm

Fastening mode

Rating Power (VA) Insulated cable: Dimension Weight (g) Cat. no.Ip/5 A Accuracy class: maximum

diameter (1)

(mm)

maximum cross-section (1)

(mm2)

opening for bars

Standard CT Tropicalised CT

Cylinder (2) Sealable cover

0,5 1 340 A - - 1 21 120 - 200 - 16500 16550 (3) built-in

50 A - 1.25 1.5 21 120 - 200 16501 16451 16550 built-in75 A - 1.5 2.5 21 120 - 200 16502 16452 16550 built-in100 A 2 2.5 3.5 21 120 - 200 16503 16453 16550 built-in

125 A 2.5 3.5 4 21 120 - 200 16504 16454 16550 built-in150 A 3 4 5 21 120 - 200 16505 16455 16550 built-in

1.5 5.5 6.5 22 150 30 x 10 270 16509 16459 16551 (4) 16552200 A 4 5.5 6 21 120 - 200 16506 16456 16550 built-in

4 7 8.5 22 150 30 x 10 270 16510 16460 16551 16552- 2 5 - - 65 x 32 600 16526 16476 - built-in

250 A 6 9 11 22 150 30 x 10 270 16511 16461 16551 165522.5 5 8 35 240 40 x 10 430 16518 16468 - 165531 4 6 - - 65 x 32 600 16527 16477 - built-in

300 A 7.5 11 13.5 22 150 30 x 10 270 16512 16462 16551 165524 8 12 35 240 40 x 10 430 16519 16469 - 165531.5 6 7 - - 65 x 32 600 16528 16478 - built-in

400 A 10.5 15 18 22 150 30 x 10 270 16513 16463 16551 165528 12 15 35 240 40 x 10 430 16520 16470 - 165534 8 10 - - 65 x 32 600 16529 16479 - built-in

500 A 12 18 22 22 150 30 x 10 270 16514 16464 16551 1655210 12 15 35 240 40 x 10 430 16521 16471 - 165532 4 6 - - 64 x 11

51 x 31500 16523 16473 - built-in

8 10 12 - - 65 x 32 600 16530 16480 - built-in600 A 14.5 21.5 26 22 150 30 x 10 270 16515 16465 16551 16552

4 6 8 - - 64 x 1151 x 31

500 16524 16474 - built-in

8 12 15 - - 65 x 32 600 16531 16481 - built-in

800 A 12 15 20 - - 65 x 32 600 16532 16482 - built-in1000 A 15 20 25 - - 65 x 32 600 16533 16483 - built-in1250 A 15 20 25 - - 65 x 32 600 - 16534 - built-in

12 15 20 - - 84 x 34 700 - 16537 - built-in8 12 - - - 127 x 38 1500 - 16540 - built-in

1500 A 20 25 30 - - 65 x 32 600 - 16535 - built-in

15 20 25 - - 84 x 34 700 - 16538 - built-in10 15 - - - 127 x 38 1000 - 16541 - built-in

2000 A 15 20 - - - 127 x 38 1000 - 16542 - built-in

2500 A 20 25 - - - 127 x 38 1000 - 16543 - built-in30 50 60 - - 127 x 52 1300 - 16545 - built-in

3000 A 25 30 - - - 127 x 38 1000 - 16544 - built-in

40 60 60 - - 127 x 52 1300 - 16546 - built-in4000 A 50 60 60 - - 127 x 52 1300 - 16547 - built-in5000 A 60 120 - - - 165 x 55 5000 - 16548 - built-in

6000 A 70 120 - - - 165 x 55 5000 - 16549 - built-in

CT cat. no. Adapter for Insulated locking screwDIN rail Mounting

plate16451...16456 b b -

16459...16471 b b b16473 and 16474 - b b16476...16483 - - b16500...16506 b b -16509...16521 b b b16523 and 16524 - b b16526...16549 - - b

23

Page 24: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

92068E_Ver4.0.fm Page 24 Jeudi, 13. avril 2006 2:46 14

Current transformers CT current transformers (cont.) 0

Choosing a current transformerChoice of a CT depends on 2 criteria:b the Ip/5 A ratiob the installation type.

The Ip/5 A ratioWe recommend that you choose the ratio immediately higher than the maximum measured current (In).Example: In = 1103 A; ratio chosen = 1250/5.For small ratings from 40/5 to 75/5 and for an application with digital devices, we recommend that you choose a higher rating, for example 100/5.This is because small ratings are less accurate and the 40 A measurement, for example, will be more accurate with a 100/5 CT than with a 40/5 CT.

The installation typeChoice of a CT model depends on the installation type:b insulated cablesb mounting on bars.

Important precautionNever open the secondary circuit of a current transformer when the primary circuit is energised.Prior to working on the secondary circuit, the secondary terminals of the current transformer must be short-circuited.

Determining the accuracy class of a CTThe accuracy class depends on the apparent power (VA) of the transformer and on consumption of the complete measurement system.The latter allows for consumption of all the devices and the connecting cables.For a given accuracy class, consumption of the measurement system must not exceed apparent power (VA) of the CT transformer.

For each temperature variation per 10°C bracket, the power drawn up by the cables increases by 4%.

Example: consumption of a measurement system at 20°C

Based on the result, the CT accuracy class is determined (see previous page):b class 3 for a 75/5 ratio CTb class 1 for a 100/5 ratio CTb class 0.5 for a 125/5 ratio CT.

Copper cable cross-section (mm2) Power in VA per doubled meter at 20°C1 11.5 0.6852.5 0.414 0.2546 0.16910 0.097516 0.062

Merlin Gerin device Consumption of the current input in VAAmmeter 72 x 72 / 96 x 96 1.1Analog ammeter 1.1IM100 digital ammeter 0.5Digital ammeter 0.3PM500, PM700, PM800, CM3000, CM4000 0.15ME4zrt 0.05PM9 0.55

PM9 0.55 VA

4 meters of 2.5 mm2 doubled wires + 1.64 VAi.e. a measurement system consumption = 2.19 VA

24

Page 25: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

92068E_Ver4.0.fm Page 25 Jeudi, 13. avril 2006 2:46 14

Current transformers CT current transformers (cont.) 0

Specific case of the motor starterTo measure motor starter current, you must choose a CT with primary current Ip = Id/2 (Id = motor starting current).

Tip:Use a current transformer to measure a nominal current of 50 A.

This is because to divide by 2 the nominal current of a transformer, you only need to pass the current to be measured twice through this transformer.

DB

1098

3450/5 A CT, Imax = 50 A

DB

1098

35

Equivalent to a 100/5 A CT, Imax = 50 A

25

Page 26: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 26 Mardi, 11. avril 2006 4:00 16

Current transformers Dimensions 0

CT current transformers

DB

1098

14

DB

1098

15

DB

1098

16

Cat. no. 16500 to 16506, 16451 to 16456 Cat. no. 16509 to 16515, 16459 to 16465 Cat. no. 16518 to 16521, 16468 to 16471

DB

1098

17

DB

1098

18

DB

1098

19Cat. no. 16523 and 16524, 16473 and 16474 Cat. no. 16526 to 16535, 16476 to 16483 Cat. no. 16537 and 16538

DB

1098

20

DB

1098

21

DB

1098

22

Cat. no. 16540 to 16544 Cat. no. 16545 to 16547 Cat. no. 16548 and 16549

Cylinders

DB

1098

23

DB

1098

24

Cat. no. 16550 Cat. no. 16551

26

Page 27: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 27 Mardi, 11. avril 2006 4:00 16

27

Page 28: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 28 Mardi, 11. avril 2006 4:00 16

Panel instruments DIN rail analog ammeters and voltmeters 0

FunctionAMPAmmeters measure the current flowing through an electric circuit in amps.

VLTVoltmeters measure the potential (voltage) difference of an electric circuit in volts.

Common technical datab Accuracy: class 1.5.b Complies with standards IEC 60051 and IEC 60414.b Ferromagnetic device.b Pseudo-linear scale over 90°.b Ammeters (except catalogue number 16029):v connection on CT, ratio In/5, to be ordered separatelyv interchangeable dials.b Temperature:v operating temperature: -25°C to +55°C.v reference temperature: 23°C.b Influence of temperature on accuracy: ±0.03 % / °C.b Utilisation frequency: 50/60 Hz.b Consumption:v AMP: 1.1 VAv VLT catalogue number 15060: 2.5 VAv VLT catalogue number 16061: 3.5 VA.b Permanent overload:v AMP: 1.2 Inv VLT: 1.2 Un.b Maximum overload for 5 s:v AMP: 10 Inv VLT: 2 Un.b Connection: tunnel terminals for 1.5 to 6 mm2 rigid cables.

Catalogue numbers

0557

39

AMP.

0557

38

VLT.

Type Scale Connectionwith CT

Width in mod.of 9 mm

Cat. no.

AMP with direct connection0-30 A no 8 16029

AMP with connection on CTBasic device(delivered without dial)

X/5 8 16030

Dial 0-5 A 160310-50 A 50/5 160320-75 A 75/5 160330-100 A 100/5 160340-150 A 150/5 160350-200 A 200/5 160360-250 A 250/5 160370-300 A 300/5 160380-400 A 400/5 160390-500 A 500/5 160400-600 A 600/5 160410-800 A 800/5 160420-1000 A 1000/5 160430-1500 A 1500/5 160440-2000 A 2000/5 16045

VLT0-300 V 8 160600-500 V 8 16061

28

Page 29: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 29 Mardi, 11. avril 2006 4:00 16

Panel instruments DIN rail digital ammeters, voltmeter and frequency meter

0

FunctionAMPAmmeters measure in amps the current flowing through an electric circuit.

VLTVoltmeters measure in volts the potential (voltage) difference of an electric circuit.

FREThe frequency meter measures in hertz the frequency of an electric circuit from 20 to 600 V AC.

Common technical datab Supply voltage: 230 V.b Operating frequency: 50/60 Hz.b Display by red LED: 3 digits, h = 8 mm.b Accuracy at full-scale : 0.5 % ±1 digit.b Consumption: max. 5 VA or rated 2.5 VA.b Degree of protection:v IP40 on front facev IP20 at terminal level.b Connection: tunnel terminals for 2.5 mm2 cables.

Specific data10 A direct reading ammeterb Minimum value measured: 4 % of rating.b Measurement input consumption: 1 VA.

Multi-rating ammeterb Ratings:v in direct reading: 5 Av by CT (not supplied) configurable on the front face of the ammeter: 10, 15, 20, 25, 40, 50, 60, 100, 150, 200, 250, 400, 500, 600, 800, 1000, 1500, 2000, 2500, 4000, 5000 A.b Minimum value measured: 4 % of rating.b Measurement input consumption: 0.55 VA.

Voltmeterb Direct measurement: 0...600 V.b Input impedance: 2 MΩ.b Minimum value measured: 4 % of rating.

Frequency meterb Minimum value measured: 20 Hz.b Maximum value measured: 100 Hz.b Full-scale display: 99.9 Hz.

Compliance with standardsb Safety: IEC/EN 61010-1.b EMC electromagnetic compatibility: IEC/EN 65081-1 and IEC/EN 65082-2.

Catalogue numbers

0596

23N

-40

AMP.

0596

24N

-40

VLT.

0596

25N

-40

FRE.

Type Scale Connectionwith CT

Width in mod.of 9 mm

Cat. no.

Direct reading AMP0-10 A No 4 15202

Multi-rating AMP0-5000 A As per rating 4 15209

VLT0-600 V 4 15201

FRE20-100 Hz 4 15208

29

Page 30: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 30 Mardi, 11. avril 2006 4:00 16

Panel instruments 72 x 72 analog ammeters andvoltmeter

0

FunctionThe 72 x 72 measurement devices are designed for flush-mounted installation on doors, wicket doors and front plates of enclosures and cubicles.

AMPThe ammeters measure in amps the current flowing through an electrical circuit.

VLTThe voltmeter measure in volts the potential difference (voltage) of an electrical circuit.

Common technical datab Accuracy: class 1.5.b Compliance with standard IEC 60414.b Ferromagnetic device.b Scale length: 62 mm over 90°.b Mounting in enclosure or in cubicle.b Degree of protection: IP52.b Maximum operating position: 30° / vertical.b Temperature:v operation: -25°C to +50°Cv reference: 23°C.b Influence of temperature on accuracy: ±0.003 % / °C.b Utilisation frequency: 50/60 Hz.

AMP specific technical datab Needs a In/5 CT to be ordered separately.b Interchangeable dials to be ordered separately.b Consumption: 1.1 VA.b Permanent overload: 1.2 In.b Maximum overload for 5 s: 10 In.

VLT specific technical datab Consumption: 3 VA.b Permanent overload: 1.2 Un.b Maximum overload for 5 s: 2 Un.

Catalogue numbers

PB

1011

18-3

0

AMP for standard feeder.

PB

1011

19-3

0

AMP for motor feeder.

PB

1011

16-3

0

VLT.

Type Scale Connectionon CT

Cat. no.

AMP for standard feederBasic device (delivered without dial) X/5 160041.3 In dial 0-50 A 50/5 16009

0-100 A 100/5 160100-200 A 200/5 160110-400 A 400/5 160120-600 A 600/5 160130-1000 A 1000/5 160140-1250 A 1250/5 160150-1500 A 1500/5 160160-2000 A 2000/5 16019

AMP for motor feederBasic device (delivered without dial) X/5 160033 In dial 0-30-90 A 30/5 16006

0-75-225 A 75/5 160070-200-600 A 200/5 16008

VLT0-500 V 16005

30

Page 31: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 31 Mardi, 11. avril 2006 4:00 16

Panel instruments 96 x 96 analog ammeters andvoltmeter

0

FunctionThe 96 x 96 measurement devices are designed for flush-mounted installation on doors, wicket doors and front plates of enclosures and cubicles.

AMPThe ammeters measure in amps the current flowing through an electrical circuit.

VLTThe voltmeter measure in volts the potential difference (voltage) of an electrical circuit.

Common technical datab Accuracy: class 1.5.b Compliance with standard IEC 60414.b Ferromagnetic device.b Scale length: 80 mm over 90°.b Mounting in enclosure or in cubicle.b Degree of protection: IP52.b Maximum operating position: 30° / vertical.b Temperature:v operation: -25°C to +50°Cv reference: 23°C.b Influence of temperature on accuracy: ±0.003 % / °C.b Utilisation frequency: 50/60 Hz.

AMP specific technical datab Needs a In/5 CT to be ordered separately.b Interchangeable dials to be ordered separately.b Consumption: 1.1 VA.b Permanent overload: 1.2 In.b Maximum overload for 5 s: 10 In.

VLT specific technical datab Consumption: 3 VA.b Permanent overload: 1.2 Un.b Maximum overload for 5 s: 2 Un.

Catalogue numbers

PB

1011

18-4

0

AMP for standard feeder.

PB

1011

19-4

0

AMP for motor feeder.

PB

1011

16-4

0

VLT.

Type Scale Connectionon CT

Cat. no.

AMP for standard feederBasic device (delivered without dial) X/5 160741.3 In dial 0-50 A 50/5 16079

0-100 A 100/5 160800-200 A 200/5 160810-400 A 400/5 160820-600 A 600/5 160830-1000 A 1000/5 160840-1250 A 1250/5 160850-1500 A 1500/5 160860-2000 A 2000/5 160870-2500 A 2500/5 160880-3000 A 3000/5 160890-4000 A 4000/5 160900-5000 A 5000/5 160910-6000 A 6000/5 16092

AMP for motor feederBasic device (delivered without dial) X/5 160733 In dial 0-30-90 A 30/5 16076

0-75-225 A 75/5 160770-200-600 A 200/5 16078

VLT0-500 V 16075

31

Page 32: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 32 Mardi, 11. avril 2006 4:00 16

Panel instruments 72 x 72 IM100 digital ammeters 0

0557

91-4

1

FunctionThe IM100 is a digital ammeter designed to measure AC currents. It provides front panel readings on switchboards and is not equipped for communication. A single device covers current-transformer ratings from 5 to 8000 A.

CharacteristicsElectrical characteristics

Type of measurement rms up to the 9th harmonic

Ratings of associated current transformers 5 to 8000 A (1)

Frequency 47 - 63 HzMeasurement accuracy (not including sensors) ±1 % of full scale, ±1 digit

Digital display 4-digit LED (9999 full-scale count)

Display-refresh time 1.5 sConsumption On power supply 3.5 VA max

On current transformer 0.5 VA at In

Overload capacity Continuous 2 In3 seconds 6 In

Electrical safety as defined by standard IEC 1010-1

Supply voltage 48 - 115 V AC / DC220 - 240 V AC380 - 415 V AC

Mechanical characteristicsDimensions DIN 72 x 72 mmWeight 0.25 kgDegree of protection (EN50102) Front face IP50

Other faces IP30 (IP20 for connections)Front face impact resistance (EN50102) IK07 (2 Joules)

Vibrations (IEC 68-2-6) Fc test 2 to 13.2 Hz - 1 mm13.2 to 100 Hz - 0.7 g

EnvironmentOperating temperature range -20 °C to +70 °C

Storage temperature range -35 °C to +85 °CDamp heat (IEC 68-2-30) 6 cycles +25 °C/ +55 °C /

RH 95 %Salt mist (IEC 68-2-52) Kb test, severity level 2Electromagnetic compatibility:

b electrostatic discharges (IEC 1000-4-2) Level IVb radiated susceptibility (IEC 1000-4-3) Level IIIb low-energy conducted susceptibility (IEC 1000-4-4) Level IV

b high-energy conducted susceptibility (IEC 1000-4-5) Level IVb conducted and radiated emissions (EN50081-2) Class A

(1) Associated current transformers: secondary output 5 A.Available primary ratings:5-20-25-30-40-50-60-70-75-80-100-120-125-150-200-250-300-400-500-600-700-750-800-1000-1200-1250-1500-2000-2500-3000-4000-5000-6000-7000-7500-8000.Recommended accuracy class: 1 (as defined by IEC 60044-1).

DB

1085

54

AccessoriesConnectionFor measurements on a 3-phase distribution system, the Digipact IM100 ammeter may be combined with a Telemecanique K1F-003M or Multi 9 4-position CMA ammeter selector switch (cat. no. 15126 and 16017).

Installationb On front plate for Prisma Plus cubicle: cat. no. 03904, 03910 or 03912b On door with cut-outs for Prisma Plus cubicle: cat. no. 08593.

Catalogue numbersVoltage Cat. no.

48 to 115 V AC / DC 50835220 to 240 V AC 50836380 to 415 V AC 50837

32

Page 33: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 33 Mardi, 11. avril 2006 4:00 16

Panel instruments 72 x 72 UM100 digital voltmeters 0

0557

93-4

1

FunctionThe UM100 is a digital voltmeter designed to measure AC voltages. It provides front panel readings on switchboards and is not equipped for communication. A single device covers all alternating voltages from 0 to 690 V.

CharacteristicsElectrical characteristics

Type of measurement rms up to the 9th harmonicMeasured voltage without voltage transformer 0 to 690 VFrequency 47 - 63 Hz

Measurement accuracy (not including sensors) ±1 % of full scale, ±1 digitDigital display 3-digit LED (999 full-scale

count)Display-refresh time 1.5 sConsumption 3.5 VA max

Input impedance > 1 MΩOverload capacity Continuous 1.2 Un

1 second 2 Un

Electrical safety as defined by standard IEC 1010-1

Supply voltage 48 - 115 V AC / DC220 - 240 V AC380 - 415 V AC

Mechanical characteristicsDimensions DIN 72 x 72 mmWeight 0.25 kg

Degree of protection (EN50102) Front face IP50Other faces IP30 (IP20 for connections)

Front face impact resistance (EN50102) IK07 (2 Joules)Vibrations (IEC 68-2-6) Fc test 2 to 13.2 Hz - 1 mm

13.2 to 100 Hz - 0.7 g

EnvironmentOperating temperature range -20 °C to +70 °CStorage temperature range -35 °C to +85 °CDamp heat (IEC 68-2-30) 6 cycles +25 °C/ +55 °C /

RH 95 %Salt mist (IEC 68-2-52) Kb test, severity level 2

Electromagnetic compatibility:b electrostatic discharges (IEC 1000-4-2) Level IVb radiated susceptibility (IEC 1000-4-3) Level III

b low-energy conducted susceptibility (IEC 1000-4-4) Level IVb high-energy conducted susceptibility (IEC 1000-4-5) Level IVb conducted and radiated emissions (EN50081-2) Class A

DB

1085

53

AccessoriesConnectionFor phase-to-phase or phase-to-neutral measurements on a 3-phase distribution system, the Digipact UM100 voltmeter may be combined with a Telemecanique K1F-027M or Multi 9 7-position CMV voltmeter selector switch (cat. no. 15125 and 16018).

Installationb On front plate for Prisma Plus cubicle: cat. no. 03904, 03910 or 03912b On door with cut-outs for Prisma Plus cubicle: cat. no. 08593.

Catalogue numbersVoltage Cat. no.

48 to 115 V AC / DC 50831220 to 240 V AC 50832380 to 415 V AC 50834

33

Page 34: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 34 Mardi, 11. avril 2006 4:00 16

Panel instruments DIN rail CMA and CMV selector switches 0

FunctionCMAThis 4-position ammeter selector switch uses a single ammeter (using current transformers) for successive measurement of the currents of a three-phase circuit.

CMVThis 7-position voltmeter selector switch uses a single voltmeter for successive measurement of voltages (phase-to-phase and phase-to-neutral) of a three-phase circuit.

Common technical datab Rotary handle.b Maximum operating voltage: 440V, 50/60 Hz.b Nominal thermal current: 10 A.b Operating temperature: -20°C to +55°C.b Storage temperature: -25°C to +80°C.b Mechanical durability (AC21A-3x440 V): 2 000 000 operations.b Degree of protection:v IP66 on front facev IP20 at terminal level.b Electrical durability: 1 000 000 operations.b Connection: jumper terminals with captive screws, for cables up to 1.5 mm2.b Complies with standards: IEC/EN 60947-3.

Catalogue numbers

Connection

0591

97

CMA.

0591

98

CMV.

Type Rating(A)

Voltage(V AC)

Width inmod. of 9 mm

Cat. no.

CMA 10 415 4 15126CMV 10 415 4 15125

DB

1033

55

CMA.

DB

1033

60

CMV.

N L3L1 L2S1

S2

4 10

3 9

2CMA

A

S1

S2 S1

S2

N L3L1 L2

12 210 6

1 3CMV

V

34

Page 35: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 35 Mardi, 11. avril 2006 4:00 16

Panel instruments 48 x 48 CMA and CMVselector switches

0

FunctionThe 48 x 48 selector switches are designed for flush-mounted installation on doors, wicket doors and front plates of enclosures and cubicles.

CMAThe ammeter selector switch uses a single ammeter (by means of current transformers) for successive measurement of the currents of a three-phase circuit.

CMVThe voltmeter selector switch uses a single voltmeter for successive measurement of the voltages (phase-to-phase and phase-to-neutral) of a three-phase circuit.

Common technical datab Durability:v electrical: 100 000 operationsv mechanical: 2 000 000 operations.b AgNi contact.b Operating temperature: -25°C to +50°C.b Compliance with standards IEC/EN 60947-3.

Catalogue numbers

Connection

Reading 3 phase-to-earth voltages + 3 phase-to-phase voltages.

Note : when connecting do not remove the pre-cabling.

0507

40-2

5

CMA.

0507

41-2

5

CMV.

Type Rating(A)

Voltage(V)

Number of positions

Cat. no.

CMA 20 4 16017CMV 500 7 16018

DB

1098

12

CMA.

DB

1098

13

CMV.

O TR SS1

S2

4 10

3 9

2CMA

A

S1

S2 S1

S2

N L3L1 L2

O TR S

12 210 8

1 3CMV

V

35

Page 36: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 36 Mardi, 11. avril 2006 4:00 16

Panel instruments CH hour counters 0

FunctionElectromechanical counter that counts the operating hours of a machine or piece of electrical equipment. Giving a precise indication of operating time, the counter is used to decide when to carry out preventive maintenance.

Common technical datab Electromechanical display.b Maximum display: 99999.99 hours.b Display accuracy: 0.01 %.b Without reset.b Storage temperature: -25°C to +85°C.b Connection: tunnel terminals for 2.5 mm2 cable.

Specific technical dataCH "DIN"b Consumption: 0.15 VA.b Operating temperature: -10°C to +70°C.b Mounting on DIN rail.

CH "48 x 48"b Consumption:v 15607: 0.25 VAv 15608: 0.15 VAv 15609: 0.02 VA to 12 V and 0.3 VA to 36 V.b Operating temperature: -20°C to + 70°C.b Degree of protection: IP65 on front face.b Mounting on front face of monitoring switchboards.

Catalogue numbers

Connection

0620

91

CH "DIN".

0620

92

CH "48 x 48".

Type Voltage(V)

Width in mod.of 9 mm

Cat. no.

CH "DIN" 230 V AC/50 Hz 4 15440CH "48 x 48" 24 V AC/50 Hz 15607

230 V AC/50 Hz 1560812 to 36 V DC 15609

E91

446a

E91

504

CH "DIN". CH "48 x 48".

CH2 3

load

+ -

CH

load

36

Page 37: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 37 Mardi, 11. avril 2006 4:00 16

Panel instruments CI impulse counter 0

FunctionElectromechanical counter designed to count impulses emitted by: kilowatt hour meters, temperature overrun detectors, people meters, speed meters, etc.

Common technical datab Supply and metering voltage: 230 V AC, 50/60 Hz.b Consumption: 0.15 VA.b Maximum display: 9 999 999 impulses.b Without reset.b Metering data:v minimum impulse time: 50 msv minimum time between 2 impulses: 50 ms.b Storage temperature: -25°C to +85°C.b Operating temperature: -10°C to +70°C.b Connection: tunnel terminals for 2.5 mm2 cable.

Catalogue number

Connection

0620

90

Type Width in mod.of 9 mm

Cat. no.

CI 4 15443

E91

445a

CI

CI

kWh

2 3

2 3

load

load

37

Page 38: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 38 Mardi, 11. avril 2006 4:00 16

Panel instruments Dimensions 0

Analog ammeters and voltmeters

DB

1034

73Digital ammeters, voltmeter and frequency meter

DB

1034

74

CMA and CMV selector switches

DB

1034

75

72 x 72 analog ammeters and voltmeter

DB

1034

76

96 x 96 analog ammeters and voltmeter

DB

1034

81

Protection cover

TerminalM4

Protection cover

TerminalM4

38

Page 39: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 39 Mardi, 11. avril 2006 4:00 16

Panel instruments Dimensions (cont.) 0

48 x 48 CMA and CMV selector switches

DB

1034

77UM100 voltmeter, IM100 ammeter

DB

1034

78

CI impulse counter and CH hour counter

DB

1034

79

48 x 48 CH hour counters

DB

1098

25

3.2 (or 4.8)

24.1 (or 33)

22.3 (or 30.5)(with adapter)

39

Page 40: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 40 Mardi, 11. avril 2006 4:00 16

Kilowatt hour meters ME watt-hour meters 0

FunctionDigital watt-hour meters designed for sub-metering of active energy (rms) consumed by a single-phase or three-phase electric circuit with or without distributed neutral.

ME1Single-phase watt-hour meter.

ME1zSingle-phase watt-hour meter with partial meter.

ME1zrSingle-phase watt-hour meter with partial meter and remote transfer of metering impulses (relay output).

ME3Three-phase watt-hour meter without neutral.

ME3zrThree-phase watt-hour meter without neutral, with partial meter and remote transfer of metering impulses (relay output).

ME4Three-phase + neutral watt-hour meter.

ME4zrThree-phase + neutral watt-hour meter with partial meter and remote transfer of metering impulses (relay output).

ME4zrtThree-phase watt-hour meter with or without neutral associated with external CTs (not supplied), with partial meter and remote transfer of metering impulses (relay output).

Catalogue numbers

Common technical data

0620

87N

ME1zr.

0620

88N

ME3zr.

0620

89N

ME4zrt.

Type Rating(A)

Voltage(V CA)

Width in mod. of 9 mm

Cat. no.

Single-phase circuit (1L + N)ME1 63 230 4 17065ME1z 63 230 4 17066ME1zr 63 230 4 17067Three-phase circuit (3L)ME3 63 3 x 400-3 x 230 8 17075ME3zr 63 3 x 400-3 x 230 8 17076ME4zrt 40...6000 3 x 400-3 x 230 8 17072Three-phase + neutral circuit (3L + N)ME4 63 3 x 230/400 8 17070ME4zr 63 3 x 230/400 8 17071ME4zrt 40...6000 3 x 230/400 8 17072

Accuracy class 2Frequency 50/60 HzConsumption 2.5 VA

Operating temperature -25°C to +55°CConnection by tunnel terminals Top terminals: 6 mm2

Bottom terminals: 16 mm2

Compliance with standard IEC 61036 (with a sealable enclosure)

40

Page 41: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 41 Mardi, 11. avril 2006 4:00 16

Kilowatt hour meters ME watt-hour meters (cont.) 0

Specific technical data

(1) example: 500/5 CT = 10,000/500 flashes per kWh = 20 flashes per kWh(2) example: 500/5 CT = 500/10 kWh per impulse = 50 kWh per impulse

ME1, ME1z and ME1zr specific technical dataME1 ME1z ME1zr

Direct measurement Up to 63 A Up to 63 A Up to 63 AMetering and activity indicator light (yellow)

1,000 flashes per kWh 1,000 flashes per kWh 1,000 flashes per kWh

Wiring error indicator Yes Yes YesTotal meter (max. capacity) on one phase

999.99 MWh 999.99 MWh 999.99 MWh

Total meter display In kWh or MWh with 5 significant digits In kWh or MWh with 5 significant digits In kWh or MWh with 5 significant digits

Partial meter (max. capacity) on one phase with RESET

- 99.99 MWh 99.99 MWh

Partial meter display - In kWh or MWh with 4 significant digits In kWh or MWh with 4 significant digitsRemote transfer - - By NO impulse contact:

- ELV insulation voltage: 4 kV, 50 Hz- 18 mA/24 V DC, 100 mA/230 V AC- 1 impulse of 200 ms (contact closing) per kWh

ME3 and ME3zr specific technical dataME3 ME3zr

Direct measurement Up to 63 A Up to 63 AMetering and activity indicator light (yellow)

100 flashes per kWh 100 flashes per kWh

Total meter (max. capacity) on one phase

999.99 MWh 999.99 MWh

Total meter display In kWh or MWh with 5 significant digits In kWh or MWh with 5 significant digitsPartial meter (max. capacity) on one phase with RESET

- 99.99 MWh

Partial meter display - In kWh or MWh with 4 significant digitsRemote transfer - By NO impulse contact:

- ELV insulation voltage: 4 kV, 50 Hz- 18 mA/24 V DC, 100 mA/230 V AC- 1 impulse of 200 ms (contact closing) every 10 kWh

ME4, ME4zr and ME4zrt specific technical dataME4 ME4zr ME4zrt

Direct measurement Up to 63 A Up to 63 A -Measurement by CT - - Ratio of 40/5 to 6,000/5 (configurable)

CT ratings to be adapted to the CTs used

- - See page 92068

Consumption of each measurement input

- - 0.05 VA to 5 A

Metering and activity indicator light (yellow)

100 flashes per kWh 100 flashes per kWh 10,000/x flashes per kWh (1)(x = CT rating)

Total meter (max. capacity) on all 3 phases

999.99 MWh 999.99 MWh Where CT y 150 A : 999.99 MWhWhere CT > 150 A : 9,999.99 MWh

Total meter display In kWh or MWh with 5 significant digits In kWh or MWh with 5 significant digits In kWh or MWh with 5 significant digitsPartial meter (max. capacity) on all 3 phases with RESET

- 99.99 MWh Where CT y 150 A : 99.99 MWhWhere CT > 150 A : 999.99 MWh

Partial meter display - In kWh or MWh with 4 significant digits In kWh or MWh with 4 significant digitsRemote transfer - By NO impulse contact:

- ELV insulation voltage: 4 kV, 50 Hz- 18 mA/24 V DC, 100 mA/230 V AC- 1 impulse of 200 ms (contact closing) every 10 kWh

By NO impulse contact:- ELV insulation voltage: 4 kV, 50 Hz- 18 mA/24 V DC, 100 mA/230 V AC- 10/x impulse of 200 ms (contact closing) per kWh = x/10 kWh per impulse (2) (x = CT rating)

41

Page 42: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 42 Mardi, 11. avril 2006 4:00 16

Kilowatt hour meters ME watt-hour meters (cont.) 0

Connection

Single-phase circuit

DB

1098

28

ME1 / ME1zr.

to impulse meter (ME1zr)

Three-phase circuit

DB

1098

29

DB

1098

30

ME3 / ME3zr. ME4zrt.

to impulse meter (ME3zr)

to impulse meter

Three-phase + neutral circuit

DB

1098

31

DB

1098

32

ME4 / ME4zr. ME4zrt.

to impulse meter

Cautionb Do not earth the CT secondary (S2).b Networks greater than 5 A: measurements require use of current transformers with a 5 A secondary.

b You must comply with the routing direction of power cables in the current transformer primary. Cables enter in "P1" and leave in "P2" to the loads.

E57

423

E57

422

P1

P2S2

S1

P1

I I

P2

to impulse meter (ME4zr)

42

Page 43: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 43 Mardi, 11. avril 2006 4:00 16

Kilowatt hour meters ME watt-hour meters (cont.) 0

Connection (cont.)

Use with a contactorA measurement instrument is normally continually supplied.For a non-continuous supply (load switching), we recommend that you place the breaking device downstream from the measurement instrument to limit disturbances on the module inputs.These disturbances, particularly on inductive loads, may result in early ageing of the device.You must also place the measurement instrument at a distance from the breaking device to limit the risk of disturbance.

Example: ME meter on a load switching:

DB

1098

33

Load Load

Circuit-breaker

Contactor

Circuit-breaker

Contactor

43

Page 44: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 44 Mardi, 11. avril 2006 4:00 16

Kilowatt hour meters Dimensions 0

ME1, ME1z and ME1zr watt-hour meters

DB

1034

83ME3, ME3zr, ME4, ME4zr, ME4zrt watt-hour meters

DB

1034

84

44

Page 45: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 45 Mardi, 11. avril 2006 4:00 16

45

Page 46: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 46 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Product selection according to measurement functions 0

Power Meter

PM9/PM9P/PM9C

PM500 PM700 PM700P PM710 PM810 PM820 PM850 PM870

IM code 510 611 to 641 521 521 521 641 772 772 774

General selection criteria

Installation On DIN rail Flush mount Flush mount Flush mount

Use on LV distribution systems b b b b b b b b b

Use on LV and HV distribution systems - b b b b b b b b

Current / voltage accuracy 0.5 % 0.5 % 0.5 % 0.5 % 0.5 % 0.1 % 0.1 % 0.1 % 0.1 %

Power / real energy accuracy 2 % 1 % 1 % 1 % 1 % 0.5 % 0.5 % 0.5 % 0.5 %

Instantaneous rms values

Current b Phases b b b b b b b b b

b Neutral b b b b b b b b b

b Extended measurement range - - - - - - - - -

Voltage b b b b b b b b b

Frequency b b b b b b b b b

Total power b Active b b b b b b b b b

b Reactive b b b b b b b b b

b Apparent b b b b b b b b b

Power per phase b Active b b b b b b b b b

b Reactive b b b b b b b b b

b Apparent - b b b b b b b b

Power factor b Total b b b b b b b b b

b Per phase - b - - - b b b b

Energy values

Active energy b b b b b In/Out In/Out In/Out In/Out

Reactive energy b b b b b In/Out In/Out In/Out In/Out

Apparent energy - b b b b b b b b

User-set accumulation mode - - - - - b b b b

Demand values

Current Present and maximum values - b b b b b b b b

Total active power Present and maximum values b b b b b b b b b

Total reactive power Present and maximum values - b b b b b b b b

Total apparent power Present and maximum values - b b b b b b b b

Total predicted demand kW, kVAR, kVA - - - - - b b b b

Synchronisation of calculation window - Option - - - b b b b

User-set calculation mode - - b b b b b b b

Other measurements

Hour counter b b b b b b b b b

(1) Measurement sensors included.(2) Not available with Digipact communication card.

46

Page 47: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 47 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Product selection according to measurement functions (cont.) 0

Circuit Monitor Micrologic control unitsfor low-voltage circuit breakers

CM3250 CM3350 CM4250 CM4000T A P H

772 774 774 777 - - -

Display in front and module on DIN rail Display in front and module inside switchboard Integrated in the circuit breaker

b b b b b b b

b b b b - - -

0.1 % 0.1 % 0.07 % 0.07 % 1.5 % (1) 1.5 % (1) 1.5 % (1)

0.5 % 0.5 % 0.2 % 0.2 % - 2.0 % (1) 2.0 % (1)

b b b b b b b

b b b b b b b

- - - - b b b

b b b b - b b

b b b b - b b

b b b b - b b

b b b b - b b

b b b b - b b

b b b b - b (2) b (2)

b b b b - b (2) b (2)

b b b b - b (2) b (2)

b b b b - b b

b b b b - b (2) b (2)

b b b b - b b

b b b b - b b

b b b b - b b

b b b b - b b

b b b b - b (2) b (2)

b b b b - b (2) b (2)

b b b b - b (2) b (2)

b b b b - b (2) b (2)

b b b b - - b (2)

b b b b - b (2) b (2)

b b b b - b (2) b (2)

- - - - - - -

Separate catalogue

47

Page 48: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 48 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Product selection according to measurement functions (cont.) 0

Power Meter

PM9/PM9P/PM9C

PM500 PM700 PM700P PM710 PM810 PM820 PM850 PM870

Power quality measurements

Interharmonics - - - - - - - - -

Total harmonic distortion b Voltage - b b b b b b b 63

b Current - b b b b b b b 63

Individual harmonic content (current and voltage) - - - - - 31 (1) 31 63 31

Waveform capture - - - - - - - b b (2)

Detection of voltage sags and swells - - - - - - - - b

Programmable (logic and mathematical functions) - - - - - - - - -

Detection and capture of transients (< 1 µs) - - - - - - - - -

Flicker - - - - - - - - -

EN 50160 compliance checking - - - - - - - b b

True rms measurement Maximum harmonic number 15 31 15 15 15 63 63 63 63

Sampling rate Points per cycle - - 32 32 32 128 128 128 128

Data recording

Min/max of instantaneous values - Option b b b b b b b

Data logging - - - - - - 2 4 4

Event logging - - - - - - b b b

Trend curves - - - - - - - b b

Alarms - Option - - - b b b b

Alarm notification via email - - - - - - - - -

Sequence of Events Recording - - - - - - - - -

Date and time stamping - - - - - b b b b

GPS time synchronisation - - - - - - - - -

Storage capacity - - - - - - 80 Ko 800 Ko 800 Ko

Display, sensors, input/outputs

Front-panel display b b b b b b b b b

Built-in current and voltage sensors - - - - - - - - -

Pulse output 1 (PM9P) Option - 2 - 1 1 1 1

Digital or analogue inputs (max. number) - 3 - - - 13 13 13 13

Digital or analogue outputs(max. number including pulse outputs)

1 (PM9P) 5 - 2 - 9 9 9 9

Input metering capability (number of channels) - - - - - 5 5 5 5

Direct voltage connections without external VT 450 V 480 V 480 V 480 V 480 V 600 V 600 V 600 V 600 V

Power supply

AC/DC version AC 230 V 110 to 400 V 110 to 415 V 110 to 415 V

DC - 120 to 350 V 125 to 250 V 125 to 250 V

DC version 24 to 48 V 24 to 48 V With CPM24 or CPM48 accessory (option)

Communication

RS 485 port b (PM9C) Option - - b 2-wire (on board)4-wire (with remote display)

Infra-red port - - - - - - - - -

RS 232 port - - - - - With remote display

Modbus (M), Digipact (D) protocol M M - - M M M M M

Ethernet port (Modbus/TCP/IP protocol) - - - - - - - - -

HTML Web-page server - - - - - - - - -

Ethernet gateway for other products on an RS 485 link - - - - - - - - -

(1) With PM810LOG.(2) Configurable.

48

Page 49: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 49 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Product selection according to measurement functions (cont.) 0

Circuit Monitor Micrologic control unitsfor low-voltage circuit breakers

CM3250 CM3350 CM4250 CM4000T A P H

- - b - - - -

b b b b b

b b b b - - b

b b b b - - b (3)

b b b b - - b (3)

- b b b - - -

- - b b - - -

- - - b - - -

- - - b - - -

b b b b - - -

63 63 255 255 12 31 31

128 128 512 100 000 at 50 Hz83 333 at 60 Hz

24 64 64

b b b b b (4) b (3) b (3)

14 14 14 14 - - -

b b b b - b (3) b (3)

b b b b - - -

b b b b - b b

Option Option Option Option - - -

b b b b - - -

b b b b - b b

Option Option Option Option - - -

Up to 8 Mo Up to 8 Mo Up to 32 Mo Up to 32 Mo - - -

Option Option Option Option b b b

- - - - b b b

1 1 1 1 - - -

4 4 16 (5) 16 (5) - - -

5 5 17 (5) 17 (5) 6 6 6

10 10 10 10 - - -

600 V 600 V 690 V 600 V 690 V 690 V 690 V

100 to 275 V (±10 %) 100 to 275 V (±10 %) (6) (6) (6)

125 to 250 V (±20 %) 125 to 250 V (±20 %) (6) (6) (6)

With CPM24 or CPM48 accessory (option) (6) (6) (6)

b b b b Option Option Option

Option Option Option Option - - -

- - b b - - -

M M M M M, D M, D M, D

Option Option Option Option - - -

Option Option Option Option - - -

Option Option Option Option - - -

(3) Not available with Digipact communication card.(4) Maximum only.(5) The total number of inputs and outputs may not exceed 25.(6) Self-powered.

Separate catalogue

49

Page 50: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 50 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Power Meter Series PM9Functions and characteristics

E90

463

The PowerLogic Power Meter Series PM9 offers the basic measurement capabilities required to monitor an electrical installation in a 4-module case (18 mm modules).

They can be used to monitor 2-, 3- and 4-wire low-voltage systems and connect to external current transformers. With the large backlit display, you can monitor all three phases at the same time.

Three versions are available for one or two supply voltages (220 to 240 V AC or 24 to 48 V DC):b PM9 for basic measurementsb PM9P for basic measurements with pulse outputb PM9C for basic measurements with Modbus RS485 output.

ApplicationsPanel instrumentation.Sub-billing / cost allocation.Remote monitoring of an electrical installation.

CharacteristicsOnly 72 mm wide (four 18 mm modules)Compact design for optimised installation.

Large backlit displaySimultaneous monitoring of all three phases.

Demand powerMonitoring of subscribed-power overruns.

IEC 62053-21 Class 2 for energyFor sub-billing and cost-allocation applications.

Part numbers

PB

1006

46-4

3

Power Meter Series PM9.

Type Voltage Width in 9 mm modules Part no.Power Meter PM9 220 to 240 V AC 8 15199Power Meter PM9P 220 to 240 V AC 8 15197Power Meter PM9C 220 to 240 V AC 8 15198Power Meter PM9 24 to 48 V DC 8 15274Power Meter PM9P 24 to 48 V DC 8 15275Power Meter PM9C 24 to 48 V DC 8 15276

50

Page 51: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 51 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Power Meter Series PM9Functions and characteristics (cont.)

Selection guide PM9 PM9P PM9CGeneral

Use on LV systems only 1P + N, 3P, 3P + N b b bCurrent and voltage accuracy 0.5 % 0.5 % 0.5 %Energy and power accuracy 2 % 2 % 2 %

Direct voltage connection 450 V 450 V 450 V

Instantaneous rms valuesCurrent 3 phases and neutral b b bVoltage Phase-to-neutral

and phase-to-phaseb b b

Frequency b b bActive and reactive power Total and per phase b b bApparent power Total b b bPower factor Total b b b

Energy valuesActive energy b b bReactive energy b b b

Demand valuesActive, reactive, apparent power Present and max. values b b b

Other measurementsHour counter b b b

Display and I/OBacklit LCD display b b bPulse output - 1 -

CommunicationRS485 port - - bModbus protocol - - b

51

Page 52: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 52 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Power Meter Series PM9Functions and characteristics (cont.)

Electrical characteristicsType of measurement On single-phase (1P + N) or three-

phase (3P, 3P + N) AC systemsMeasurement accuracy Current and voltage 0.5 % of reading

Power 2 % of reading from pf 0.8 leading to 0.5 lagging

Frequency 0.2 HzPower factor 2 % from 0.5 leading to 0.5 laggingActive energy Class 2 as defined by IEC 62053-21

Reactive energy Class 2 as defined by IEC 62053-23 Input-voltage characteristics

Measured voltage 50 to 450 V AC (direct)and up to 1000 V AC (with external VT)

Permissible overload 1.15 UnFrequency measurement range

45 to 65 Hz

Input-current characteristics CT ratings Adjustable from 5 to 10000 A

Secondary 5 AMetering over-range 15 mA to 6 APermissible overload 6 A continuous

20 A 10 s50 A 1 s

Load 0.55 VAInput current Not isolated

Control Power AC 220 to 240 V AC (±10 %), < 5 VADC 24 to 48 V DC (±20 %)

Pulse output (PM9P) Static output, 350 V AC/DC max.,130 mA max. at 25 °C, derating 1 mA/°C above 25 °C, 5 kV insulation

Mechanical characteristicsWeight 0.3 kgIP degree of protection IP52 (front display)

Dimensions 72 x 90 x 66 (mm)Connection Tunnel terminals, 1 x 4 mm2

Environmental conditionsOperating temperature -5 °C to +55 °CPollution degree 2

Installation category III for distribution systems up to 260/450 V

Electromagnetic compatibility

Electrostatic discharge Level III (IEC 61000-4-2)Immunity to radiated fields

Level III (IEC 61000-4-3)

Immunity to fast transients

Level IV (IEC 61000-4-4)

Immunity to impulse waves

Level IV (IEC 61000-4-5)

Conducted and radiated emissions

Class B (CISPR11)

Safetye

CommunicationRS485 port (PM9C)remote reading and reset

2-wire, 9600 or 19200 bauds, Modbus RTU, ELSV circuit, 6 kV impulse withstand (double insulation)

52

Page 53: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 53 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Power Meter Series PM9Installation and connection

Dimensions

DB

1019

50

53

Page 54: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 54 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Power Meter Series PM9Installation and connection (cont.)

PM9/4-wire connection with 3 CTs

DB

1100

47

Connection example.

PM9P/4-wire connection with 3 CTs

DB

1100

48

Connection example.

Note: other types of connection are possible. See product documentation.

54

Page 55: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 55 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Power Meter Series PM9Installation and connection (cont.)

PM9C/4-wire connection with 3 CTs

DB

1100

49

Connection example.

Note: other types of connection are possible. See product documentation.

55

Page 56: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

432E2260_Ver1.2.fm Page 62 Mardi, 18. avril 2006 5:08 17

Power-monitoring units Power Meter Series 700 0

Functions and characteristics

E90

463

The PowerLogic Power Meter Series 700 offers all the measurement capabilities required to monitor an electrical installation in a single 96 x 96 mm unit extending only 50 mm behind the mounting surface.

With its large display, you can monitor all three phases and neutral at the same time. The anti-glare display features large 11 mm high characters and powerful backlighting for easy reading even in extreme lighting conditions and viewing angles.

The Power Meter Series 700 is available in three versions:b PM700, basic version with THD and min/max readingsb PM700P, basic version plus two pulse outputs for energy meteringb PM710, basic version plus an RS485 port for Modbus communication.

ApplicationsPanel instrumentation.Sub-billing and cost allocation.Remote monitoring of an electrical installation.Harmonic monitoring (THD).

CharacteristicsRequires only 50 mm behind mounting surfaceThe Power Meter Series 700 can be mounted on switchboard doors to maximise free space for electrical devices.

Large back lit display with integrated bar chartsDisplays 4 measurements at a time for fast readings.

Intuitive useEasy navigation using context-sensitive menu.

Power and current demand, THD and min/max reading in basic versionA high-performance solution for trouble-free monitoring of your electrical installation.

Energy class 1 as defined by IEC 62053-21Suitable for sub-billing and cost-allocation applications.

PB

1007

08

Part numbersPower Meter Series 700

PM700 Power Meter PM700MGPM700P Power Meter PM700PMGPM710 Power Meter PM710MG

62

Page 57: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 63 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Power Meter Series 700 0

Functions and characteristics (cont.)

D

B10

1047

Selection guide PM700 PM700P PM710General

Use on LV and HV systems b b bCurrent and voltage accuracy 0.5 % 0.5 % 0.5 %Energy and power accuracy 1.0 % 1.0 % 1.0 %

Instantaneous rms valuesCurrent Phases and neutral b b bVoltage Ph-Ph and Ph-N b b bFrequency b b bActive, reactive, apparent power Total and per phase b b bPower factor Total b b b

Energy valuesActive, reactive, apparent energy b b b

Demand valuesCurrent Present and max. b b bActive, reactive, apparent power Present and max. b b b

DB

1010

48

Setting of calculation mode Block, sliding b b bOther measurements

Hour counter b b b

Power quality measurementsHarmonic distortion Current and voltage b b b

Data recordingMin/max of instantaneous values b b b

Display and I/OBacklit LCD display b b bPulse output - 2 -

CommunicationRS485 port - - bModbus protocol - - b

Power Meter Series 700.1 Mounting slots.2 RS485 communications (PM710) or

2 pulse outputs (PM700P).3 Heartbeat LED.4 Power supply.5 Voltage inputs.6 Current inputs.

63

Page 58: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 64 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Power Meter Series 700 0

Functions and characteristics (cont.)

PB

1007

10

Electrical characteristicsType of measurement True rms up to the 15th harmonic

On three-phase (3P, 3P + N) two-phase and single-phase AC systems32 samples per cycle

Measurement accuracy

Current and voltage 0.5 %Power 1 %Frequency ±0.01 Hz from 45 to 65 HzActive energy Class 1 as defined by IEC 62053-21Reactive energy Class 2 as defined by IEC 62053-23

Data update rate 1 s Input-voltage characteristics

Measured voltage 10 to 480 V AC (direct Ph-Ph)10 to 277 V AC (direct Ph-N)10 to 1600 kV AC (with external VT)

Metering over-range 1.2 UnImpedance 2 MΩ (Ph-Ph) / 1 MΩ (Ph-N)Frequency range 45 to 65 Hz

Rear view of Power Meter Series 700. Input-current characteristics

CT ratings Primary Adjustable from 5 A to 32767 ASecondary 5 A

Measurement input range 10 mA to 6 APermissible overload 15 A continuous

50 A for 10 seconds per hour120 A for 1 second per hour

Impedance < 0.1 Ω Load < 0.15 VA

Power supply AC 110 to 415 ±10 % V AC, 5 VADC 125 to 250 ±20 % V DC, 3 WRide-through time 100 ms at 120 V AC

Output Pulse output (PM700P) Static output 240 ±10 % V AC or 300 ±10 % V DC, 100 mA max. at 25 °C, derate 0.56 mA per °C above 25°C, 2.41 kV rms isolation

Mechanical characteristicsWeight 0.37 kgIP degree of protection (IEC 60529) IP52 front display, IP30 meter bodyDimensions 96 x 96 x 69 mm (meter with display)

96 x 96 x 50 mm (behind mounting surface)

Environmental conditionsOperating temperature

Meter 0 °C to +60 °CDisplay 0 °C to +50 °C

Storage temp. Meter + display -40 °C to +85 °CHumidity rating 5 to 95 % RH at 50 °C (non-condensing)Pollution degree 2Metering category III, for distribution systems up to 277/480 V ACDielectric withstand As per EN 61010, UL508

Electromagnetic compatibilityElectrostatic discharge Level III (IEC 61000-4-2)Immunity to radiated fields Level III (IEC 61000-4-3)Immunity to fast transients Level III (IEC 61000-4-4)Immunity to impulse waves Level III (IEC 61000-4-5)Conducted immunity Level III (IEC 61000-4-6)Immunity to magnetic fields Level III (IEC 61000-4-8)Immunity to voltage dips Level III (IEC 61000-4-11)Conducted and radiated emissions e commercial environment/FCC part 15 class B

EN 55011Harmonics emissions IEC 61000-3-2Flicker emissions IEC 61000-3-3

64

Page 59: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 65 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Power Meter Series 700 0

Functions and characteristics (cont.)

SafetyEurope e, as per IEC 61010-1U.S. and Canada UL508

CommunicationRS485 port (PM710) 2-wire, up to 19200 bauds, Modbus RTU, SELV

circuit, 6 kV impulse (double insulation)

Display characteristicsDimensions 73 x 69 mm Back-lit green LCD

(6 lines total, 4 concurrent values)

Firmware characteristicsMin./max. Worst min. and max. with phase indication for

voltages, currents and THD. Min. and max. values for power factor, power (P, Q, S) and frequency

65

Page 60: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 66 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Power Meter Series 700 0

Installation and connection

Dimensions

DB

1010

39

DB

1010

40

DB

1084

03

Front-panel mounting

DB

1010

42

66

Page 61: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 67 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Power Meter Series 700 0

Installation and connection (cont.)

4-wire connection with 3 CTs and no PT

DB

1084

06

Connection example.

3-wire connection with 2 CTs and 2 PTs

DB

1084

07

Connection example.

Note: Other types of connection are possible. See product documentation.

67

Page 62: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 68 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Power Meter Series 800 0

Functions and characteristics

E90

463

The PowerLogic Power Meter Series 800 offers all the high-performance measurement capabilities needed to monitor an electrical installation in a compact 96 x 96 mm unit. Its easy-to-read display shows all three phases and neutral at the same time.

Standard features of the Series 800 Power Meters include an RS485 Modbus communication port (ASCII and RTU), digital input and digital output, THD metering, alarming and input metering capability. The PM820 and PM850 also offer custom on-board logging and individual current and voltage harmonic readings. The PM850 includes waveform capture. The PM870 is the first compact meter to offer voltage and current disturbance (sag and swell) detection and configurable waveform capture.

ApplicationsPanel instrumentationb sub-billing, cost allocation and utility bill verificationb remote monitoring of an electrical installationb mid-range power quality analysis and energy management (the PM870 includes sag and swell detection)b utility contract optimization and load preservation.

CharacteristicsEasy to installMounts with only two clips. No tools required.

Direct connect voltage inputsNo need for potential transformers (PTs) up to 600 V AC.

Easy to operateIntuitive navigation with self-guided, language-selectable menus.

System status at a glanceLarge, anti-glare display with back-light provides summary screens with multiple values. Bar charts graphically represent system loading and I/O.

Custom alarming with time stampingOver 50 alarm conditions, including over or under conditions, digital input changes, phase unbalance and more. Boolean logic can be used to combine up to four alarms.

Power quality analysis The Power Meter Series 800 supports EN 50160 power quality evaluation. The PM850 includes waveform capture. The PM870 features voltage and current disturbance (sag and swells) detection and configurable waveform capture. And both the PM850 and PM870 include current and voltage individual harmonic magnitudes and angles that help troubleshoot and prevent power quality problems.

Extensive on-board memory Billing (energy and demand), power quality and alarm logs are stored in non-volatile memory.

IEC 62053-22 class 0.5S for real energy Accurate energy measurement for sub-billing and cost allocation.

Trend curves and short-term forecasting (PM850 and PM870) Trend and compare energy and demand readings. Forecast upcoming values to anticipate and manage future energy costs.

WAGES capability Five channels available on all models for input metering of various utilities (WAGES: water, air, gas, electricity, steam).

Modular and upgradeable Easy-to-install option modules (memory and I/O) and downloadable firmware for enhanced meter capabilities.

Remote display The optional remote display can be mounted as far as 10 m from the metering unit. The adapter includes an additional RS485/RS232 communication port.

PB

1003

13

68

Page 63: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 69 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Power Meter Series 800 0

Functions and characteristics (cont.)

PB

1015

48

Remote display adapter with remote display and cable.

Part NumbersDescriptionPower Meter with Integrated Display

PM810 power meter with integrated display, basic instrumentation, THD, alarming

PM810MG

PM820 power meter with integrated display, basic instrumentation, THD, alarming, 80 kb logging

PM820MG

PM850 power meter with integrated display, basic instrumentation, THD, alarming, 800 kb logging, waveform capture

PM850MG

PM870 power meter with integrated display, basic instrumentation, THD, alarming, 800 kb logging, configurable waveform capture and disturbance detection

PM870MG

Power Meter Unit (No Display)PM810 power meter unit only, no display PM810UMGPM820 power meter unit only, no display PM820UMG

PB

1015

49

Side view I/O modules and Power Meter Series 800.

PM850 power meter unit only, no display PM850UMGPM870 power meter unit only, no display PM870UMGOptionnal modules

2 digital outputs (relays), 2 digital inputs PM8M222 digital outputs (relays), 6 digital inputs PM8M262 digital outputs (relays), 2 digital inputs, 2 analog outputs, 2 analog inputs PM8M2222PM810 optional logging module for on-board data recording, uses a non-volatile, battery-backed internal clock

PM810LOG

Parts and accessoriesRemote display and adapter with a 3.55 m (12 ft) cable PM8RDMGRemote display adapter only PM8RDARJ11 Extender kit to mount RJ11 jack in panel door (for use with PM800, CM3000, and CM4000 series meters)

RJ11EXT

Cable for remote display adapter 1.25 m (4 ft) CAB4Cable for remote display adapter 3.65 m (12 ft) CAB12Cable for remote display adapter 9.14 m (30 ft) CAB30

Display selection guideApplicationMeter and integrated display mounted on door

PB

1015

51

Use the meter with an integrated display when door space is available and when voltage usage is within the local regulation limits.

PM810MGPM820MGPM850MGPM870MG

Meter with no display

PB

1015

50

Use the base meter unit without a display to comply with voltage limitations for local regulations when door mounting is not possible, or when meter voltage exceeds regulations, or when local display is not required.

When the meter is used without a display, configuration of the communications port is limited to the default (address 1, 9600 baud, parity even). Requires System ManagerTM Software (SMS) to read data.

PM810UMGPM820UMGPM850UMGPM870UMG

Remote display

PB

1015

54

Meter and remote display kitConveniently packaged kit consist of a base meter (810, 820, or 850) with a remote display, remote display adapter, and remote display cable 3.6 m (12 ft).

PM810RDMGPM820RDMGPM850RDMGPM870RDMG

PB

1015

52

Remote display adapter aloneWhen added to the front of the base unit (PM8xxU), the adapter brings two additional communication ports: one for the remote display and one 4-wire/2-wire RS485/RS232.

PM8RDA

PB

1015

55

Remote display and cable Use this combination of remote display, adapter, and 3.6 m (12 ft) cable to equip a base meter unit for use with a remote display. In addition, the display can be carried from meter to meter, enabling you to purchase one display for multiple meters. Each base unit meter must be equipped with a remote display adapter (PM8RDA).

PM8RDMG

69

Page 64: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 70 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Power Meter Series 800 0

Functions and characteristics (cont.)

D

B10

9268

Meter selection guide PM810 PM820 PM850 PM870General

Use on LV and HV systems b b b bCurrent and voltage accuracy 0.1 % 0.1 % 0.1 % 0.1 %Active energy and power accuracy 0.5 % 0.5 % 0.5 % 0.5 %

Number of samples per cycle 128 128 128 128

Instantaneous rms valuesCurrent, voltage, frequency b b b bActive, reactive,apparent power

Total and per phase b b b b

Power factor Total and per phase b b b b

Energy valuesActive, reactive, apparent energy b b b bConfigurable accumulation mode b b b b

Demand valuesCurrent Present

and max. valuesb b b b

Active, reactive,apparent power

Presentand max. values

b b b b

Predicted active, reactive, apparent power b b b bSynchronisation of the measurement window b b b bDemand calculation mode

Block, sliding b b b b

Other measurementsHour counter b b b b

Power-quality measurementsHarmonic distortion Current and voltage b b b bIndividual harmonics Current and voltage 31 (1) 31 63 63

Waveform capture - - b bSag and swell detection - - - b

Data recordingMin/max of instantaneous values b b b bData logs - 2 4 4

Event logs - b b bTrending / forecasting - - b b

Power Meter Series 800.1 Control power supply connector.2 Voltage inputs.3 Digital input/output.4 RS485 port.5 Option module connector.6 Current inputs.

Alarms b b b bTime stamping b b b b

Display and I/OWhite backlit LCD display b b b bMultilingual: English, French, Spanish b b b bDigital input 1 1 1 1

Digital output or pulse output 1 1 1 1Input metering capability (number of channels) 5 5 5 5

CommunicationRS485 port 2-wire 2-wire 2-wire 2-wireModbus protocol b b b bRS232/RS485, 2- or 4-wire Modbus RTU/ASCII (with addition of PM8RDA module)

b b b b

(1) With PM810LOG.

I/O selection guideThe PM800 can be fitted with 2 optional modules, unless otherwise indicated (2)

PM8M22 module2 digital outputs (relays) for control or alarms

2 digital inputs for position monitoring

PM8M26 module2 digital outputs (relays) for control or alarms6 digital inputs for position monitoring or pulse countingThis module includes a 24 V DC power supply that can be used to bias the digital inputs

PM8M2222 module2 digital outputs (relays) for control or alarms

2 digital inputs for position monitoring or pulse counting2 analog outputs 4-20 mA2 analog inputs 0-5 V or 4-20 mA

(2) It is not possible to mount two PM8M22 modules. If the supply voltage of the PM800 is less than 208 V, only one PM8M2222 module can be mounted.

45

6

1

2 3

70

Page 65: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 71 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Power Meter Series 800 0

Functions and characteristics (cont.)

P

B10

0315

Rear view of Power Meter Series 800.

Electrical characteristicsType of measurement True rms up to the 63rd harmonic

On three-phase AC system (3P, 3P + N)128 samples per cycleOn single phase AC system (L-L, L-N, L-L+N)

Measurement accuracy

Current and voltage ±0.075 % of reading + ±0.025 % of full scalePower PM810 ±0.5 % of reading + ±0.025 % of full scale

PM820/PM850 ±0.15 % of reading + ±0.025 % of full scaleFrequency ±0.01 Hz from 45 to 67 Hz

±0.01 Hz from 350 to 450 HzActive energy IEC 62053-22 and ANSI C12.20 Class 0.5SReactive energy IEC 62053-23 Class 2

Data update rate 1 s Input-voltage characteristics

Measured voltage 0 to 600 V AC (direct L-L)0 to 347 V AC (direct L-N)0 to 3.2 MV AC (with external VT)

Metering over-range 1.5 UnImpedance 2 MΩ (L-L) / 1 MΩ (L-N)Frequency measurement range

45 to 67 Hz and 350 to 450 Hz

Input-current characteristics

CT ratings Primary Adjustable from 5 A to 32.767 kASecondary 1 A or 5 A

Measurement input range 0 to 10 APermissible overload 15 A continuous

50 A for 10 seconds per hour500 A for 1 second per hour

Impedance < 0.1 Ω Load < 0.15 VA

Control Power AC 110 to 415 ±10 % V AC, 11 VADC 125 to 250 ±20 % V DC, 6 WRide-through time 45 ms at 120 V AC

Input/outputs PM800

Static pulse output Static output (6 to 220 ±10 % V AC or 3 to 250 ± 10 % V DC, 100 mA max. at 25 °C)1350 V rms isolation

Digital input 24 to 125 V AC/DC (±10 %)5 mA max. burden

OptionsPM8M22 Relay outputs 0 to 240 V AC or 0 to 30 V DC

2 A rms, 5 A max. for 10 seconds per hour Digital inputs 19 to 30 V DC, 5 mA max. / 24 V DC

PM8M26 Relay outputs 0 to 240 V AC, 0 to 30 V DC2 A rms, 5 A max. for 10 seconds per hour

Digital inputs 20 to 150 V AC/DC, 2 mA max.24 V internal supply 20 - 30 V DC, 10 mA max. (feeds 8 digital

inputs)PM8M2222 Relay outputs 0 to 240 V AC, 0 to 30 V DC

2 A rms, 5 A max. for 10 seconds per hourDigital inputs 20 to 150 V AC/DC, 2 mA max.Analog outputs 4-20 mA, burden 0 to 600 Ω max.Analog inputs Adjustable from 0 to 5 V DC or 4-20 mA

Switching frequency

PM8M22 Input/output 1 Hz, 50 % duty cycle (500 ms ON/OFF)PM8M26 andPM8M2222

Input 25 Hz, 50 % duty cycle (20 ms ON/OFF)Output 1 Hz, 50 % duty cycle (500 ms ON/OFF)

Mechanical endurance (digital outputs) 15 million operationsElectrical endurance (digital outputs) 250000 commutations at 2 A / 250 V ACInstallation category of options II (1)

Mechanical characteristicsWeight (meter + integrated display) 0.6 kgIP degree of protection (IEC 60529) IP52 front display, IP30 meter bodyDimensions Without options 96 x 96 x 70 mm (behind mounting surface)

With 1 option 96 x 96 x 90 mm (behind mounting surface)

Environmental conditionsOperating temperature

Meter -25 °C to +70 °C (2)

Display -10 °C to +50 °CStorage temperature

Meter + display -40 °C to +85 °C

Humidity rating 5 to 95 % RH at 40 °C (non-condensing)Pollution degree 2Installation category III, for distribution systems up to 347 V L-N /

600 V AC L-L Dielectric withstand As per EN 61010, UL508(1) Installation category II, for power systems up to 347 V AC / 600 V AC.(2) 65 °C if control power is above 305 V AC.

71

Page 66: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 72 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Power Meter Series 800 0

Functions and characteristics (cont.)

D

B10

9269

PM800 Series with I/O module.

Electromagnetic compatibilityElectrostatic discharge Level III (IEC 61000-4-2)

Immunity to radiated fields Level III (IEC 61000-4-3)Immunity to fast transients Level III (IEC 61000-4-4)Immunity to impulse waves Level III (IEC 61000-4-5)

Conducted immunity Level III (IEC 61000-4-6)Immunity to magnetic fields Level III (IEC 61000-4-8)Immunity to voltage dips Level III (IEC 61000-4-11)

Conducted and radiated emissions

e industrial environment/FCC part 15 class AEN 55011

Harmonics emissions IEC 61000-3-2Flicker emissions IEC 61000-3-3

SafetyEurope e, as per IEC 61010-1U.S. and Canada UL508

CommunicationRS 485 port 2-wire, up to 38400 baud, Modbus

Firmware characteristicsData Logs PM820, PM850 and PM870:

- 1 billing log- 1 customizable logPM850 and PM870 only: 2 additional custom logs

Min./max. Worst min. and max. with phase indication for Voltages, Currents, Voltage unbalance, and THD. Min. and max. values for power factor (True and Displacement), power (P, Q, S) and frequency

One event log Time stamping to 1 secondTrend curves(PM850 and PM870 only)

Four trend curves: 1 minute, 1 hour, 1 day and 1 month. Min./max./avg. values recorded for eight parameters: - every second for one minute for the 1-minute curve- every minute for one hour for the 1-hour curve- every hour for one day for the 1-day curve- every day for one month for the 1-month curve

Energy per interval Up to three user-defined intervals per dayAvailable for all models (the PM810 requires the PM810LOG module)

Forecasting(PM850 and PM870 only)

Forecasting of the values for the trended parameters for the next four hours and next four days

PM850 waveform capture Triggered manually or by alarm, 3-cycle, 128 samples/cycle on 6 user configurable channels

PM870 enhanced waveform capture

From 185 cycles on 1 channel at 16 samples per cycle up to 3 cycles on 6 channels at 128 samples per cycle

DB

1092

70

Alarms Adjustable pickup and dropout setpoints and time delays, numerous activation levels possible for a given type of alarm

Historical and active alarm screens with time stamping

Four priority levels

Response time: 1 second

Boolean combination of four alarms is possible usingthe operators NAND, OR, NOR and XOR on PM850 and PM870

Digital alarms: status change of digital inputsMemory available for logging and waveform capture

80 kbytes in PM820800 kbytes in PM850 and PM870

Firmware update Update via the communication portsFile download available free from powerlogic.com website

Bar graphs Graphical representation of system performance

Display characteristicsLanguages English, French, Spanish

PM800 Series display screen showing bar graphs. Display screen Back-lit white LCD (6 lines total, 4 concurrent values)

Dimensions Display screen viewable area 73 x 69 mmIntegrated display Overall 96 x 96 mm

Depth meter + display 69.4 mm + 17.8 mm

Remote display Overall 96 x 96 x 40 mmWeight Meter with remote display adapter 0.81 kg

Remote display 0.23 kg

72

Page 67: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 73 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Power Meter Series 800Installation and connection

Power meter with integrated displayDimensions

DB

1005

62

DB

1005

63

DB

1005

64

Front-panel mounting (meter with integrated display)

DB

1005

65

Spacing between units

DB

1005

68

DB

1005

69

73

Page 68: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 74 Mardi, 11. avril 2006 4:00 16

Power-monitoring units 0Power Meter Series 800Installation and connection (cont.)

Remote display door mounting Flush mounting

DB

1085

21

Surface mount

DB

1085

22

For mounting in a Ø102 cutout(to replace an analogue device: ammeter, voltmeter, etc.)

DB

1085

23

74

Page 69: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 75 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Power Meter Series 800Installation and connection (cont.)

4-wire connection with 3 CTs and no PT

DB

1085

32

Connection example.

3-wire connection with 2 CTs and 2 PTs

DB

1085

24

Connection example.

Note: Other types of connection are possible. See product documentation.

75

Page 70: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 76 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Power Meter Series 800Installation and connection (cont.)

PM8M22 module

DB

1085

25

PM8M2222 module

DB

1085

31

76

Page 71: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 77 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Power Meter Series 800Installation and connection (cont.)

PM8M26 module internal 24 V DC power supply

DB

1085

29

PM8M26 module external power supply

DB

1085

30

77

Page 72: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

432E3170_Ver3.2.fm Page 78 Jeudi, 13. avril 2006 2:47 14

Power-monitoring units Power Meter Series 800Installation and connection (cont.)

Remote display kit

DB

1092

74Dimension (meter with I/O and remote display adapter)

DB

1084

73

4-wire connection (RS 485) of remote display adapter

DB

1092

76

2-wire connection (RS 485) of remote display adapter

DB

1092

77

A BC D E A. I/O modules

B. Power meter 800 series (base unit)C. Remote display adapterD. CAB12 cableE. Remote display (rear view)

TX–

RX–TX+

TX

/ R

X

RX+

TX–

RX–TX+

RX+

TX–

RX–TX+

RX+

3090MCTAS485

24

23

22

21

20

TX–

RX–TX+

TX

/ R

X

RX+

TX–

RX–TX+

RX+

TX–

RX–TX+

RX+

24

23

22

21

20

78

Page 73: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

432E3170_Ver3.2.fm Page 79 Jeudi, 13. avril 2006 2:47 14

Power-monitoring units Power Meter Series 800Installation and connection (cont.)

2-wire daisy-chain connection of devices (RS 485)

DB

1085

49

4-wire daisy-chain connection of devices, connected to 2-wire Modbus or Jbus connection of devices (RS 485)

DB

1092

79

–+

Belden 9841 or equivalent MCT2W terminator onthe last device of thedaisy chain

Belden 9841 wire colors: blue with white stripe (+), white with blue stripe (–), and silver (shield)

20 RX+

21 RX–

22 TX+

23 TX–

24 SHLD

18

19 –

20 +

Belden 8723 or equivalent

Jumpers

Belden 9841 or equivalent

MCT2W terminator

PM800

CM3000, CM400 or PM600

From Master (Host) Device

79

Page 74: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 80 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Circuit Monitor Series 3000 0

Functions and characteristics

E

9046

3

The PowerLogic Circuit Monitor CM3250 and CM3350 are high-performance acquisition and control devices offering numerous measurement functions. They integrate easily in power monitoring and control systems due to their Ethernet connections and embedded web server. They are Transparent Ready.

Whether installed at the service entrance, at the head of a switchboard or on sensitive-equipment feeders, Circuit Monitor units record the electrical parameters of the installation. They provide the information required to control costs, improve power quality and reduce equipment downtime.

The CM3350 detects and captures voltage sags and swells that may cause halts in production.

ApplicationsPanel instrumentation.Sub-billing / cost allocation.Remote monitoring of an electrical installation.Comprehensive power-quality monitoring.EN 50160 electricity supply compliance checking.Contract and load curve optimisation.Metering of other utilities

CharacteristicsDetection and capture of voltage sags and swellsRapid identification of the underlying causes of problems.

Trend curves and short-term forecastingRapid trending and forecasting of upcoming values for better decision making.

Acquisition of rms values every 100 msPreventive maintenance, e.g. acquisition of a motor start-up curve, etc.

Electricity quality checking in compliance with EN 50160Fast standardised check on the quality of the electricity supplied.

8 Mbytes of memoryFor archiving of data and waveforms.

Ethernet 10/100 Mbits/s card Rapid data transfers over an intranet or the internet.

Server for custom HTML pagesAccess to the information without any special tools, simply a web browser.

Up to nine input/outputs to monitor the electrical installationStatus of circuit breakers, as well as metering of other commodities, gas, water, etc.

IEC 60687 and ANSI C12.20 Class 0.5S for energyVerification of consumption and load curves.

6211

1

Circuit Monitor Series 3000 + vacuum fluorescent display (VFD).

Part numbersCircuit Monitor Series 3000

Circuit Monitor CM3250 CM3250MGCircuit Monitor CM3350 CM3350MG

OptionsSee page 82.

80

Page 75: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 81 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Circuit Monitor Series 3000 0

Functions and characteristics (cont.)

E

9420

9

Selection guide CM3250 CM3350General

Use on LV and HV systems b bCurrent and voltage accuracy 0.1 % 0.1 %Energy and power accuracy 0.5 % 0.5 %

Number of samples per cycle 128 128

Instantaneous rms valuesCurrent, voltage, frequency b bActive, reactive, apparent power Total and per phase b bPower factor Total and per phase b b

Energy valuesActive, reactive, apparent energy b bSettable accumulation mode b b

Demand valuesCurrent Present and max.

valuesb b

Active, reactive, apparent power Present and max. values

b b

Predicted active, reactive, apparent power b bSynchronisation of the measurement window b b

Circuit Monitor Series 3000. Setting of calculation mode Block, sliding b b1 Current/voltage inputs2 Settings lock, sealable access door.3 Maintenance LED indicator.4 Power LED indicator.5 Control power-supply connector.6 RS485 port with transmit and receive LED indicators.7 Slot for optional card.8 Display communication port.9 KYZ pulse output.

Power-quality measurementsHarmonic distortion Current and voltage b bIndividual harmonics 63 63Waveform capture b bDetection of voltage sags and swells - bFast acquisition of 100 ms data - bVerification of compliance with EN 50160 (1) b b

Data recordingMin/max of instantaneous values b b

Data logs b bEvent logs b b

E87

306

Trending / forecasting b bAlarms b bSER (Sequence of Event Recording) b bTime stamping b bGPS synchronisation (1 ms) IOC44 option8 Mbyte memory b b

Display and I/ODisplay CMDLC or CMDVF option

Multilingual: French, English, Spanish b bWiring self-test b bPulse output b bMaximum number of I/Os 9 9Input metering capability (number of channels) 10 10Direct voltage connection 600 V 600 V

Disturbance waveform capture: detection of a voltage sag. CommunicationRS485 port 2/4 wires 2/4 wires

Infrared port CMDVF optionModBus protocol b bEthernet card (Modbus/TCP/IP protocol) ECC21 option

HTML-page web server ECC21 optionEthernet gateway for third-party products ECC21 option(1) Except for interharmonics, signalling voltages, flicker and transients.

81

Page 76: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

432E2250_Ver2.1.fm Page 82 Jeudi, 13. avril 2006 2:48 14

Power-monitoring units Circuit Monitor Series 3000 0

Functions and characteristics (cont.)

The Circuit Monitor have two optional display units, an LCD display and a vacuum fluorescent display (VFD). They may be used for local circuit-monitor setup and operation.

0591

56

CMDLC displayBack-lit LCD display with four lines and 20 characters per line. The display unit hasfour navigation buttons, a contrast button and a red alarm LED. It connects to the Circuit Monitor via a CAB12 cable, 4.2 metres long, supplied with the display.

Part numbers

LCD display supplied with the CAB12 cable CMDLCMGConnection cables: Circuit Monitor <-> display

1.25 m (4 ft) CAB43.65 m (12 ft) CAB129.14 m (30 ft) CAB30

0591

55

CMDVF displayVacuum fluorescent display (VFD) with four lines and 20 characters per line. The display unit has four navigation buttons, a contrast button, a red alarm LED and an infrared port. The infrared port is used with the OCIVF accessory and may serve to set up or operate the circuit monitor from a computer. The display comes with a cable for connection to the Circuit Monitor (CAB12 cable, 4.2 m long).

Part numbers

VFD supplied with the CAB12 cable CMDVFMGConnection cables: Circuit Monitor <-> display

1.25 m (4 ft) CAB43.65 m (12 ft) CAB129.14 m (30 ft) CAB30

0591

59

OCIVF optical communication interfaceAccessory for transmission between the infrared port on the CMDVF display and a PC computer.

Part number

Optical communication interface OCIVF

E87

288

1 Display screen.2 Infrared port (VFD display only).3 Alarm LED.4 Arrow buttons.5 Menu button.6 Proximity sensor (VFD display only).7 Enter button.8 Contrast button.

Display.

82

Page 77: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 83 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Circuit Monitor Series 3000 0

Functions and characteristics (cont.)

0591

41

Ethernet ECC21 communication cardThe ECC21 is an optional Ethernet communication card. It may be installed in the slot in the circuit monitor intended for options. It has two main functions:b equip the circuit monitor with a fast Ethernet connection over a 10/100 Mbits/s copper link or a 100 Mbits/s fiber-optic linkb serve as an Ethernet gateway for devices daisy chained to its RS485 ModBus port.The ECC21 card also includes a server for six HTML pages that may be consulted by a standard web browser. These pages can be customised using WPG software and display information from the host circuit monitor and/or devices connected to its ModBus port.

Part number

Ethernet communication card ECC21

0591

42

IOC44 cardThe IOC44 is an optional input/output card equipped with:b 4 digital inputs 20 - 138 V AC/DCb 4 digital outputs, including 3 relay outputs and a static output that may be programmed as a pulse output. Status changes on the digital inputs are time-stamped to within 1 ms. The IOC44 card may be installed in the option-card slot of the circuit monitor and may be used to:b monitor the electrical installation, notably the status of the circuit breakers, and check discrimination between protection devicesb measure the consumption of other commodities by counting the pulses sent by water or gas meters.

Part number

IOC44 card IOC44

83

Page 78: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 84 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Circuit Monitor Series 3000 0

Functions and characteristics (cont.)

62

109

Series 3000 + optional ECC21 or IOC44.

Electrical characteristicsType of measurement True rms up to the 63rd harmonic

On three-phase AC system (3P, 3P+N)128 samples per cycle

Measurement accuracy

Current and voltage ±0.075 % of reading + ±0.025 % of full scalePower ±0.075 % of reading + ±0.025 % of full scale

Frequency ±0.01 Hz from 45 to 67 Hz±0.01 Hz from 350 to 450 Hz

Energy IEC 60687 and ANSI C12.20 Class 0.5SData update rate 1 s in normal mode and 100 ms in 100 ms modeInput-voltage characteristics

Measured voltage 0 to 600 V AC (direct)0 to 1200 kV AC (with external VT)

Measurement range 0 to 1.5 Un

Impedance > 2 MΩFrequency measurement range

45 to 67 Hz and 350 to 450 Hz

Input-current characteristics

CT ratings Adjustable from 5 A to 30 000 AMeasurement range 5 mA to 10 A

Permissible overload 15 A continuous50 A for 10 seconds per hour500 A for 1 second per hour

Impedance < 0.1 Ω

Load < 0.15 VASupply AC 100 to 275 V AC (±10 %), 27 VA

DC 125 to 250 V DC (±20 %), 16 W

Ride-through time 99 ms at 120 V Ac / 75 ms at 125 V DCInput/outputs Pulse output Static output (240 V AC max., 100 mA max.)

IOC44 card (optional) 4 digital inputs (20-138 V AC/DC),3 relay outputs (5 A to 240 V AC)1 static output (96 mA max. at 240 V AC)

Mechanical characteristicsWeight 1.1 kgIP degree of protection (IEC 60529) IP52

Dimensions CM3250/3350 210 x 105 x 143 mm

Environmental conditionsOperating temperature

CM3250/CM3350 -25 °C to +70 °CCMDLC display -20 °C to +60 °CCMDVF display -20 °C to +70 °C

Storage temperature

CM + displays -40 °C to +85 °C

Humidity rating 5 to 95% RH at 40 °CPollution degree 2Installation category III, for distribution systems up to 277/480 V (1)

Dielectric withstand As per EN 61010, UL508Electromagnetic compatibility

Electrostatic discharge Level 3 (IEC 61000-4-2)

Immunity to radiated fields Level 3 (IEC 61000-4-3)Immunity to fast transients Level 3 (IEC 61000-4-4)Immunity to impulse waves Level 3 (IEC 61000-4-5)

Conducted and radiated emissions e industrial environ./FCC part 15 class AEN 55011

(1) Category II for distribution systems higher than 277/480 V.

84

Page 79: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 85 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Circuit Monitor Series 3000 0

Functions and characteristics (cont.)

E

8730

9

SafetyEurope e, as per IEC 61010

U.S. and Canada UL508

CommunicationRS485 port (1) 2/4 wires, up to 38400 bauds, ModBus, SELV circuit, 6 kV

impulse (double insulation)

Infrared port (optional) (1) IrDa, up to 38400 bauds, ModBusEthernet ECC21 card with HTML server (optional) (1)

Copper Ethernet link 10/100 BaseTX, RJ45 connector, 100-metre link

Fiber-optic Ethernet link 100 Base FX, LC duplex connector, 1300 nm, FO multimode with gradient index 62.5/125 µmor 50/125 µm, 2000-metre link

Protocol ModBus/TCP/IP

Gateway function for products connected to the ECC21

Master Modbus port, 31 daisy-chained slaves, 63 with repeater, 2/4 wires, 1200 to 38400 bauds,also compatible with the PowerLogic protocol

Example of a CM3250 HTML page showing instantaneous values.

HTML server 1 standard page, 5 customisable pages

Firmware characteristics14 data logs Up to 96 different parameters, factory-set logs ready to use

One 100 ms data log Parameters recorded every 100 ms for events(CM3350 only)

One min./max. log -One min./max./avg. log Min./max./avg. values recorded for 23 parameters

at regular intervals from 1 to 1440 minutesOne event log Time stamping to 1 ms, synchronisation 1 ms by GPSTrend curves Four trend curves: 1 minute, 1 hour, 1 day and 1 month.

Min./max./avg. values recorded for eight parameters:- every second for one minute for the 1-minute curve- every minute for one hour for the 1-hour curve- every hour for one day for the 1-day curve- every day for one month for the 1-month curve

Forecasting Forecasting of the values for the eight parametersfor the next four hours and next four days

Waveform capture Standard: manual launch, 1 cycle, 128 samples, 63rd harmonicDisturbance: manual launch or by alarm,128 samples per cycle, adjustable from 12 to 80 cycles,response time less than 0.5 cycle, number of cyclesbefore alarm settable from 2 to 10

Alarms Adjustable pickup and dropout setpoints and time delays, numerous activation levels possible for a given typeof alarmFour priority levels

Three response times: standard 1 second, fast 100 ms, disturbance < 0.5 cycle (CM3350 only)

Boolean combination of four alarms is possible usingthe operators NAND, OR, NOR and XOR

Digital alarms, e.g. status change of digital inputsMemory 8 Mbytes standardFirmware update Update via the communication ports

Display characteristicsCMDLC (optional) Back-lit LCD

CMDVF (optional) Vacuum fluorescent display (VFD) with IR portLanguages French, English, Spanish(1) All the communication ports may be used simultaneously.

85

Page 80: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 86 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Circuit Monitor Series 3000 0

Installation and connection

Dimensions

E94

212

E94

211

E94

210

Mounting on DIN rail

E94

221

E94

220

Mounting possibilities

E94

215

E94

216

E94

217

E94

218

E94

219

Vertical mounting. Horizontal mounting. Vertical mounting.

86

Page 81: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 87 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Circuit Monitor Series 3000 0

Installation and connection (cont.)

CMDLC/CMDVF dimensions

E87

286

E87

285

Mounting on a backplate

E94

377

87

Page 82: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 88 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Circuit Monitor Series 3000 0

Installation and connection (cont.)

3-wire connection with 2 CTs and no PT

DB

1084

18

4-wire connection with 4 CTs and 3PTs

DB

1084

19

88

Page 83: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 89 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Circuit Monitor Series 3000 0

Installation and connection (cont.)

Ethernet ECC21 communication card

DB

1084

16

IOC44 input/output card

DB

1084

17

89

Page 84: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 90 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Circuit Monitor Series 4000 0

Functions and characteristics

90

E90

463

The PowerLogic Circuit Monitor Series 4000 offers high-performance digital instrumentation, data acquisition and control capabilities. The products can integrate easily in power monitoring and control systems due to their optional Ethernet connections and embedded web server. They are Transparent Ready.These devices are designed for applications where power quality and availability are critical factors. They are generally used at service entrances and interconnection points or on circuits feeding sensitive equipment. Due to their very wide range of features, including transient detection, it is possible to rapidly solve problems related to poor power quality. EN 50160 compliance checking capability makes these products ideal to meet new needs related to market deregulation.The Circuit Monitor Series 4000 is available in two versions:b CM4250, with detection of voltage sags, swells and other power quality indicesb CM4000T, with detection of voltage sags and swells together with transient detection and flicker measurements.

ApplicationsPanel instrumentation.Sub-billing / cost allocation.Remote monitoring of an electrical installation.Extensive power-quality monitoring.Contract and load curve optimisation.EN 50160 electrical supply compliance checking.Metering of other utilities.

Main characteristicsDisturbance direction detectionIndication of whether the source of a specific power quality event is upstream or downstream from the meter.

Power quality summaryConsolidation of all the power quality characteristics into a single trendable index.

Adaptive waveform captureCapture of long-duration events.

Shift energy summaryIndication of energy usage per shift up to three shifts a day.

IEC 61000-4-7, IEC 61000-4-30 complianceMeasurement of harmonics, interharmonics and power quality.

Detection and capture of voltage sags and swellsFast identification of problems causing production shutdown.

Detection and capture of short transients less than 1 µs(optional, CM4000T only)Identification of problems due to short disturbances, e.g. switching of capacitors, etc.

Flicker evaluation based on IEC 61000-4-15 and IEEE 1453 (CM4000T only)Measurement of rapid voltage variations.

Electrical quality checking in compliance with EN 50160Fast standardised check on the quality of the electricity supplied.

Detection of major waveform changesDetection of phase switching phenomena (for example during the transfer of a high-speed static switch) not detected by classical threshold-based alarms.

Ultra-fast recording of electrical parameters every 100 ms or every cyclePreventive maintenance: acquisition of a motor startup curve, etc.

Trend curves and short-term forecastingRapid trending and forecasting of upcoming values for better decision making.

Automatic alarm settingAlarm setpoint learning feature for optimum threshold settings.

Up to 32 Mbytes of memory (16 Mbytes standard)For archiving of data and waveforms.

Ethernet 10/100 Mbits/s card and server for HTML pages(with optional Ethernet card)Rapid data transfers over an intranet or the internet, simply using a web browser.

Alarm notification via emailHigh-priority alarms sent directly to the user's PC.Instant notification of power quality events by email.

Up to 25 inputs/outputs to monitor the electrical installation(with optional I/O cards)Status of circuit breakers, as well as metering of other commodities, e.g. gas, water, etc.

IEC 62053-22 and ANSI C12.20 Class 0.2S for energyVerification of consumption and load curves.

PB

1017

23_5

8

CM4000 + vacuum fluorescent display (VFD).

Page 85: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 91 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Circuit Monitor Series 4000 0

Functions and characteristics (cont.)

Part numbersCircuit Monitor Series 4000

Circuit Monitor CM4250 CM4250MGCircuit Monitor CM4000T CM4000TMG

OptionsSee page 92.

DB

1081

68

CM4000.

1 Current/voltage module.2 Control power-supply connector.3 Maintenance LED indicator.4 Power LED indicator.5 RS 485 port with transmit and receive LED indicators.6 Display communication port.7 Slots for optional cards.8 RS 232 port with transmit and receive LED indicators.9 KYZ pulse output.10 Sealable access door.

Selection guide CM4250 CM4000TGeneral

Use on LV and HV systems b bCurrent and voltage accuracy 0.07 % 0.07 %Energy and power accuracy 0.2 % 0.2 %

Nbr of samples/cycle or sample frequency 512 5 MHz

Instantaneous rms valuesCurrent, voltage, frequency b bActive, reactive, apparent power Total and per phase b bPower factor Total and per phase b b

Energy valuesActive, reactive, apparent energy b bSettable accumulation modes b b

Demand valuesCurrent Present and max. values b bActive, reactive, apparent power Present and max. values b bPredicted active, reactive, apparent power b bSynchronisation of the measurement window b bSetting of calculation mode Block, sliding b b

Power quality measurementsInterharmonics b -

Harmonic distortion Current and voltage b bIndividual harmonics Via monitor 63 63

Via SMS 255 255

Waveform capture b bDetection of voltage swells and sags b bAdaptive waveform capture (up to 64 s) b bDetection and capture of transients (< 1 µs) - bFlicker - bFast acquisition of 100 ms or cycle by cycle data b bEN 50160 compliance checking (1) b bProgrammable (logic and math functions) b b

Data recording

E87

306

Min/max of instantaneous values b bData logs b bEvent logs b bTrending/forecasting b bAlarms (optional automatic alarm setting) b bAlarm notification via email ECC21 optionSER (Sequence of Event Recording) b bTime stamping b bGPS synchronisation (1 ms) IOC44 optionMemory expandable up to 32 Mbytes 32 Mbytes

Display and I/ODisplay CMDLC or CMDVF optionMultilingual: English, French, Spanish, German, Italian, Polish b bWiring self-test b bPulse output b b

Disturbance waveform capture: detection of a voltage sag. Maximum number of I/Os 25 25

Input metering capability (number of channels) 10 10Direct voltage connection 690 V 600 V

CommunicationRS 485 port 2/4 wires 2/4 wiresInfrared port CMDVF option

RS 232 port b bModbus protocol b bEthernet card (Modbus/TCP/IP protocol) ECC21 option

HTML-page web server ECC21 optionEthernet gateway for third-party products ECC21 option(1) Except for interharmonics, signalling voltages, flicker and transients.

91

Page 86: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

432E2010_Ver2.1.fm Page 92 Jeudi, 13. avril 2006 2:49 14

Power-monitoring units Circuit Monitor Series 4000 0

Functions and characteristics (cont.)

The Circuit Monitor has two optional display units, an LCD display and a vacuum fluorescent display (VFD). They may be used for local circuit-monitor setup and operation.

PB

1017

18_5

8

CMDLC displayBack-lit LCD display with four lines and 20 characters per line. The display unit hasfour navigation buttons, a contrast button and a red alarm LED.It connects to the Circuit Monitor via a CAB12 cable, 4.2 metres long, supplied with the display.

Part numbers

LCD display supplied with the CAB12 cable CMDLCMGConnection cables: Circuit Monitor <-> display

1.25 m (4 ft) CAB43.65 m (12 ft) CAB129.14 m (30 ft) CAB30

PB

1017

20_5

8

CMDVF displayVacuum fluorescent display (VFD) with four lines and 20 characters per line. The display unit has four navigation buttons, a contrast button, a red alarm LED and an infrared port. The infrared port is used with the OCIVF accessory and may serve to set up or operate the Circuit Monitor from a computer. The display comes with a cable for connection to the Circuit Monitor (CAB12 cable, 4.2 m long).

Part numbers

VFD supplied with the CAB12 cable CMDVFMGConnection cables: Circuit Monitor <-> display

1.25 m (4 ft) CAB43.65 m (12 ft) CAB129.14 m (30 ft) CAB30

0591

59

OCIVF optical communication interfaceAccessory for transmission between the infrared port on the CMDVF display and a PC computer.

Part number

Optical communication interface OCIVF

E87

288

1 Display screen.2 Infrared port (VFD display only).3 Alarm LED.4 Arrow buttons.5 Menu button.6 Proximity sensor (VFD display only).7 Enter button.8 Contrast button.

Display.

92

Page 87: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 93 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Circuit Monitor Series 4000 0

Functions and characteristics (cont.)

05

9141

Ethernet ECC21 communication cardThe ECC21 is an optional Ethernet communication card. It may be installed in the slot in the Circuit Monitor intended for options. It has two main functions:b equip the Circuit Monitor with a fast Ethernet connection over a 10/100 Mbits/s copper link or a 100 Mbits/s fiber-optic linkb serve as an Ethernet gateway for devices daisy chained to its RS 485 ModBus port.The ECC21 card also includes a server for six HTML pages that may be consulted by a standard web browser. These pages can be customised using WPG software and display information from the host Circuit Monitor and/or devices connected to its ModBus port.

Part number

Ethernet communication card ECC21

0592

17

CVM42 current/voltage moduleThis is the CM4250 acquisition module for currents and voltages. It is supplied already installed on the CM4250. If the Circuit Monitor must be recalibrated, this is the only module requiring recalibration. It may be installed and removed in the field. This module may also be replaced in the field by a CVMT module to transform a CM4250 into a CM4000T.

Part number

Current/voltage module for CM4250 CVM42

CVMT current-voltage moduleThis is the CM4000T acquisition module for currents and voltages, i.e. it is suitable for the detection of transient phenomena with a 5 MHz voltage-sampling rate. Similar to the CVM42, it may be installed and removed in the field. It is supplied already installed on the CM4000T.

Part number

CM4000T current/voltage module CVMT

Memory extension kitThese kits make it possible to extend the Circuit Monitor memory to 16 MB or 32 MB.

Part numbers

16 MB kit CM4MEM16M32 MB kit CM4MEM32M

93

Page 88: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 94 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Circuit Monitor Series 4000 0

Functions and characteristics (cont.)

Input/output blocks may be added to the Circuit Monitor to:b monitor the electrical installation, notably the status of the circuit breakers, and check discrimination between protection devicesb measure the consumption of other commodities by counting the pulses sent by water or gas metersb measure the temperature of the transformersb transmit parameters over analog channels to other systemsb etc.The Circuit Monitor may be equipped with a total of 25 optional digital or analog input/outputs.These input/outputs may be added in two different manners:b either using an IOC44 cardb or the IOX input/output extender module and individual input/output modules that connect to the extender.All these options may be installed in the field. Status changes on the digital inputs are time-stamped to within the millisecond.

0591

42

IOC44 cardThis is an input/output card equipped with:b 4 digital inputs 20 - 138 V AC/DCb 4 digital outputs, including 3 relay outputs and a static output that may be programmed as a pulse output. It may be installed in the option-card slots of the Circuit Monitor.There are three possible configurations:b 1 IOC44 cardb 2 IOC44 cardsb 1 IOC44 card and 1 Ethernet ECC21 card.

Part number

IOC44 card IOC44

0591

45

IOX input/output extenderThe IOX input/output extender may be equipped with up to eight plug-in input or output modules. The entire unit connects to the side of the Circuit Monitor. The input/output modules may be digital or analog.Three pre-equipped versions may be ordered directly, the IOX08, IOX0404 and IOX2411. Other versions may be user prepared by ordering an empty IOX extender and separate I/O modules (see the section on I/O Modules for selection). In this case, the IOX extender may be equipped with up to a maximum of four analog modules.

DescriptionIOX extender Empty extender with eight slots for separate input and/or

output modules, digital or analog, with however a maximum of four analog modules.

IOX extender equipped with two input/output modules. IOX08 extender IOX extender equipped with:8 digital input modules 120 V AC

0591

44

IOX0404 extender IOX extender equipped with:4 digital input modules 120 V AC4 analog input modules 4-20 mA

IOX2411 extender IOX extender equipped with:2 digital output modules 60 V DC4 digital input modules 32 V DC

1 analog output module 4-20 mA1 analog input module 0-5 V

Part numbers

IOX extender IOXIOX2411 pre-equipped extender module. IOX08 extender IOX08

IOX0404 extender IOX0404IOX2411 extender IOX2411

94

Page 89: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 95 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Circuit Monitor Series 4000 0

Functions and characteristics (cont.)

05

9160

Input/output modulesThe input/output modules are installed in the slots of the IOX extender. One module corresponds to either one input or one output. A number of versions are available, digital and analog inputs and outputs, and different voltage levels.

DescriptionDI120AC module One digital input 120 V ACDI240AC module One digital input 240 V ACDI32DC module One polarised digital input 32 V DC, switching time 0.2 ms

DO120AC module One digital output 120 V AC, 3.5 A maxDO240AC module One digital output 240 V AC, 3.5 A maxDO200DC module One digital output 200 V DC, 3.5 A max

DO60DC module One digital output 60 V DC, 3.5 A maxAI05 module One analog input 0-5 V DCAI420 module One analog input 4-20 mA

AO420 module One analog output 4-20 mA, max. load 250 Ω

Part numbers

DI120AC module DI120ACDI240AC module DI240ACDI32DC module DI32DCDO120AC module DO120ACDO240AC module DO240ACDO200DC module DO200DCDO60DC module DO60DCAI05 module AI05AI420 module AI420AO420 module AO420

95

Page 90: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 96 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Circuit Monitor Series 4000 0

Functions and characteristics (cont.)

P

B10

1725

_60

CM4000 + options: ECC21, IOC44 and IOX2411.

Electrical characteristicsType of measurement True rms up to the 255th harmonic

On three-phase AC system (3P, 3P + N)Up to 512 samples per cycleUp to 5 MHz for transient events (CM4000T only)

Measurement accuracy

Current and voltage ±0.04 % of reading + ±0.025 % of full scalePower ±0.075 % of reading + ±0.025 % of full scaleFrequency ±0.01 Hz from 45 to 67 Hz

±0.1 Hz from 350 to 450 HzPower factor ±0.002 from 0.5 leading to 0.5 lagging

Energy:CM4250/CM4000T

IEC 62053-22 and ANSI C12.20 Class 0.2S

Data update rate 1 s in normal modeInput-voltage characteristics

Measured voltage 0 to 600 V AC on CM4000T (direct)0 to 690 V AC on CM4250 (direct)0 to 1200 kV AC (with external VT)

Measurement range 0 to 1.5 UnImpedance > 2 MΩ Frequency measurement range

45 to 67 Hz and 350 to 450 Hz

Input-current characteristics

CT ratings Adjustable from 5 A to 30 000 A

Measurement rangeCM4250/CM4000T

5 mA to 10 A

Permissible overload 15 A continuous50 A for 10 seconds per hour500 A for 1 second per hour

Impedance < 0.1 Ω

Load < 0.15 VAPower supply AC 100 to 275 V AC (±10 %), 50 VA

DC 125 to 250 V DC (±20 %), 30 WRide-through time 100 ms at 120 V DC

Input/outputs Pulse output Static output (240 V AC max, 96 mA max)

IOC44 card (optional) 4 digital inputs (20-138 V AC/DC),3 relay outputs (5 A to 240 V AC)1 static output (96 mA max to 240 V AC)

IOX extender (optional) Slots for 8 I/Os

IOX08 (optional) 8 digital inputs 120 V ACIOX0404 (optional) (1) 4 dig. inputs 120 V AC, 4 analog outputs 4-20 mAIOX2411 (optional) (1) 2 dig. outputs 120 V AC, 4 dig. inputs 32 V DC,

1 analog input 0-5 V, 1 analog output 4-20 mA

Mechanical characteristicsWeight 1.9 kgIP degree of protection (IEC 60529) IP52

Dimensions CM4250/CM4000T

Without IOX accessory 235.5 x 165.6 x 133.1 mmWith IOX accessory 235.5 x 216.3 x 133.1 mm

Environmental conditionsOperating temperature

Circuit Monitor -25 °C to +70 °CCMDLC display -20 °C to +60 °C

CMDVF display -20 °C to +70 °CStorage temperature

CM + displays -40 °C to +85 °C

Humidity rating 5 to 95 % RH at 40 °CPollution degree 2

Installation category

CVM42 IVCVMT II

Dielectric withstand As per EN 61010, UL508, CSA C22.2-2-4-M1987

Electromagnetic compatibilityElectrostatic discharge Level 3 (IEC 61000-4-2)Immunity to radiated fields Level 3 (IEC 61000-4-3)

Immunity to fast transients Level 3 (IEC 61000-4-4)Immunity to impulse waves Level 4 (IEC 61000-4-5)Conducted and radiated emissions e industrial envir./FCC part 15 class A

SafetyEurope e, as per CEI 61010

USA and Canada UL508 and CSA C22.2-2-4-M1987(1) Operating limits: 0° C to +60 °C. Storage limits: -25 °C to +85 °C.

96

Page 91: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 97 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Circuit Monitor Series 4000 0

Functions and characteristics (cont.)

E

8730

7

CommunicationRS 485 port (1) 2/4 wires, up to 38400 bauds, Modbus

RS 232 port (1) Up to 38400 bauds, Modbus, direct connection to a PC or modem

Infrared port (optional) (1) IrDa, up to 38400 bauds, ModbusEthernet ECC21 card with HTML server (optional) (1)

Copper Ethernet link 10/100 BaseTX, RJ45 connector, 100 m link

Fiber-optic Ethernet link 100 Base FX, LC duplex connector, 1300 nm, FO multimode with gradient index 62.5/125 µm or 50/125 µm, 2000 m link

Protocol Modbus/TCP/IP

Gateway function for products connected to the ECC21

Master Modbus port, 31 daisy-chained slaves, 63 with repeater, 2/4 wires, 1200 to 38400 bauds,also compatible with the PowerLogic protocol

HTML server 1 standard page, 5 customisable pages

Firmware characteristicsAdaptive waveform capture: transformer inrush current. 14 data logs Up to 96 different parameters, factory-set logs ready

to use

One 100 ms data log Parameters recorded every 100 ms for eventsOne 20 ms (50 Hz) or 16 ms (60 Hz) data log

Parameters recorded every 20 ms or 16 ms for events

E87

308

One min/max log -

One min/max/avg. log Min/max/avg. values recorded for 23 parameters at regular intervals from 1 to 1440 minutes

One event log Time stamping to 1 ms, synchro. 1 ms by GPSTrend curves Four trend curves: 1 minute, 1 hour, 1 day and 1 month.

Min./max./avg. values recorded for eight parameters:- every second for one minute for the 1-minute curve- every minute for one hour for the 1-hour curve- every hour for one day for the 1-day curve- every day for one month for the 1-month curve

Forecasting Forecasting of the values for the eight parametersfor the next four hours and next four days

Waveform captures Standard: manual launch, 1 cycle, 512 samples, 255th harmonicDisturbance: manual launch or by alarm, adjustable from 512 samples/cycle over 28 cycles to 16 samples/cycle over 915 cycles, response time less than 0.5 cycle, number of cycles before alarm settable from 2 to 10Adaptive: manual launch or by alarm, adjustable from 512 samples/cycle over 8 seconds to 16 samples/cycle over 264 seconds, capture takes place during a set duration or as long as an alarm is active (to save memory), number of cycles before alarm settable from 2 to 10Transient: voltage sampling at 5 MHz (83 333 samples/cycle) over 2 ms to capture transient peaks < 1 µs

Adaptive waveform capture: motor start, rms value.

E87

309

Alarms Threshold alarms:- adjustable pickup and dropout setpoints and time delays, numerous activation levels possible for a given type of alarm- 4 priority levels- 4 response times: standard 1 s, fast 100 ms,disturbance < 1/2 cycle, transient < 1µs- boolean combination of four alarms is possible using the operators NAND, OR, NOR and XORAutomatic alarm setting: after a learning phase, the alarm thresholds are set automatically. The alarms will trip in the event of drift with respect to reference values determined during the learning period.Digital alarms: logic input transitionsWaveform alarms: alarm tripping by a special algorithm when the current or voltage waveform is distorted beyond an adjustable level. Makes it possible to detect disturbances that cannot be detected by classical threshold alarms (e.g. phase switching).

Example CM4250 HTML page showing instantaneous values.

Memory 8 Mbytes standard, expandable up to 32 Mbytes

Firmware update Update via the communication ports

Display characteristicsCMDLC (optional) Back lit LCDCMDVF (optional) Vacuum fluorescent display (VFD) with IR portLanguages English, French, Spanish, German, Italian, Polish

(1) All the communication ports may be used simultaneously.

97

Page 92: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 98 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Circuit Monitor Series 4000 0

Installation and connection

CM4250 / CM4000T dimensions

E94

393

E94

394

E94

392

Mounting on a backplate

DB

1081

69

98

Page 93: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 99 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Circuit Monitor Series 4000 0

Installation and connection (cont.)

Mounting possibilities

DB

1080

07

DB

1080

05D

B10

8006

Vertical mounting. Horizontal mounting.

CMDLC/CMDVF dimensions

E87

286

E87

285

Mounting on a backplate

E94

377

99

Page 94: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 100 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Circuit Monitor Series 4000 0

Installation and connection (cont.)

3-wire connection with 2 CTs and no PT

DB

1080

08

4-wire connection with 4 CTs and 3PTs

DB

1080

09

100

Page 95: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 101 Mardi, 11. avril 2006 4:00 16

Power-monitoring units Circuit Monitor Series 4000 0

Installation and connection (cont.)

Ethernet ECC21 communication card IOX input/output extender

DB

1080

10

DB

1080

11

IOC44 input/output card

DB

1080

12

101

Page 96: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

432E4010_Ver3.1.fm Page 102 Mardi, 18. avril 2006 2:27 14

Communicationand supervision

Communication interfaces and associated services 0

Switchboard-data acquisition and monitoring make it possible to anticipate events. In this way, they reduce customer costs in terms of operation, maintenance and investment.

Serial linkWith communication technology, it is no longer necessary to be physically present at the site to access information. Data is transmitted by networks.

In all architectures, the communication interface serves as the link between the installation devices and the PC running the operating software. It provides the physical link and protocol adaptation. Adaptation is required because the communication systems used by the PC (Modbus via RS232 and/or Ethernet) are generally not those used by the installation devices (e.g. the Modbus protocol via RS485).

Dedicated application software prepares the information for analysis under the best possible conditions.

DB

1084

30

Modbus communication architecture.

In addition, an EGX100 in serial port slave mode allows a serial Modbus master device to access information from other devices across a Modbus TCP/IP network.

DB

1092

80

Modbus communication across Ethernet network

EGX100serial slave mode

Modbus master device

102

Page 97: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

432E4010_Ver3.1.fm Page 103 Mardi, 18. avril 2006 2:27 14

Communicationand supervision

Communication interfaces and associated services (cont.) 0

E90

463

Ethernet linkUsing modern Web technologies, the operator can access information from monitoring and protection devices using any PC connected to the network, with all the required security.

The Ethernet EGX100 gateway or the EGX400 servers provide connectivity between Modbus RS485 and Ethernet Modbus TCP/IP (1).

DB

1094

31

Ethernet communication architecture.

The services available with these technologies considerably simplify the creation, maintenance and operation of these supervision systems.

The application software is now standardised: the web interface into the system does not require custom web pages to be created. It is personalised by simply identifying the components in your installation and can be used as easily as any internet application.

These services are part of the Transparent Ready Equipment offer. The first step in this approach is the EGX400 server with HTML pages set up by the WebPageGenerator (WPG). System Manager Software (SMS), running on a PC, provides broader coverage for more specific needs.

(1) The ECC21 card, an option for the CM3000 and CM4000 Circuit Monitors, also serves as an interface between Modbus RS485 and Ethernet Modbus TCP/IP.

EGX100 EGX400

103

Page 98: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 104 Mardi, 11. avril 2006 4:00 16

Communicationand supervision

EGX100 Ethernet gateway

E90

463

FunctionThe EGX100 serves as an Ethernet gateway for PowerLogic System devices and for any other communicating devices utilizing the Modbus protocol.The EGX100 gateway offers complete access to status and measurement information provided by the connected devices, for example, via the System ManagerTM Software (SMS) installed on a PC.

System ManagerTM Software (SMS)SMS power-monitoring software is recommended as a user interface because it provides access to all status and measurement information. It also prepares summary reports.

Architecture

PB

1015

56

DB

1092

81

SetupSetup via an Ethernet networkOnce connected to an Ethernet network, the EGX100 gateway can be accessed by a standard internet browser via its IP address to:b specify the IP address, subnet mask, and gateway address of the EGX gatewayb configure the serial port parameters (baud rate, parity, protocol, mode, physical interface, and timeout value)b create user accountsb create or update the list of the connected products with their Modbus or PowerLogic communication parametersb configure IP filtering to control access to serial devicesb access Ethernet and serial port diagnostic datab update the firmware.

Setup via a serial connectionSerial setup is carried out using a PC connected to the EGX100 via an RS232 link. This setup:b specifies the IP address, subnet mask, and gateway address of the EGX gatewayb specifies the language used for the setup session.

Part number

EGX100 Ethernet gateway EGX100MG

SMS

Ethernet Modbus TCP/IP

EGX100 gateway

Modbus RS485 serial link

PM800 Micrologic PM500 Sepam

104

Page 99: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 105 Mardi, 11. avril 2006 4:00 16

Communicationand supervision

EGX400 Ethernet server

E90

463

FunctionThe EGX400 server is used as an Ethernet gateway for PowerLogic System devices and for any other communicating devices utilizing Modbus protocol. The EGX400 offers the following features and benefits:b HTML pages (set up using WebPageGenerator "WPG") that can be accessed using a standard web browser and are used to display the information provided by the devices connected to the serverb Historical data logs from serial devices on 5, 10, 15, 30, or 60 minute intervalsb E-mail historical data logs on a user-defined scheduleb Supports SNMP (Simple Network Management Protocol) using MIB2 (Management Information Base)b Supports SNTP (Simple Network Time Protocol) for time synchronization.

System ManagerTM Software (SMS) and internet browserThe EGX400 server makes it possible to implement two types of user interface:b SMS power-monitoring software providing access to all status and measurement information. SMS includes a powerful reporting tool that provides pre-defined and user-defined summary reports for PQ, energy, and other area of interest. b a standard web browser providing access to the main information organised in predefined HTML pages.These two approaches, SMS and web browser, are complementary:b SMS offers complete access to all information, but must be installed on each PCb the HTML pages offer partial access to the main information via any PC connected to the network.

Architecture

PB

1007

04_6

8

DB

1094

29

SetupInitial setupThe initial setup is carried out using a PC connected to the EGX400 via an RS232 link. This setup:b specifies the IP address of the EGX400 serverb selects the type of Ethernet port (wire or optic fiber)b lists the connected products with their Modbus communication parameters.

Setup via the Ethernet networkOnce connected to the Ethernet network, the EGX400 server can be accessed by a standard web browser via its IP address to:b configure serial port parametersb create or update the list of the connected products with their Modbus communication parametersb access Ethernet and serial line diagnosticsb update the firmware.

Part number

EGX400 Ethernet server EGX400MG

105

Page 100: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 106 Mardi, 11. avril 2006 4:00 16

Communicationand supervision

EGX100 Ethernet gatewayEGX400 Ethernet server

EGX100

1 24 Vdc power connection.2 10/100 Base TX (802.3af) port for connection to Ethernet

via an RJ45 connector.3 Ethernet and serial indication LEDs.4 Power/Status LED.5 Reset button.6 RS485 connection.7 Dip switches for biasing, termination, and 2-wire/4-wire

jumpers.8 RS232 connection.

EGX400

1 Power connector.2 Ethernet indication LEDs.3 10/100 Base TX port for connection to Ethernet via an

RJ45 connector.4 100 Base FX port for connection to Ethernet via fiber optic

cable (LC connector).5 COM1: terminal block for RS485 serial link.6 COM1 indication LEDs.7 COM2: terminal block for RS485 serial link.8 COM2 indication LEDs.9 Dip-switches for setup of COM1 and COM2 ports bias and

termination.10 COM2: Sub D-9 connector for the RS232 serial link.

CharacteristicsEGX100 EGX400

Weight 170 g 700 g

DB

1092

82

Dimensions (H x W x D) 91 x 72 x 68 mm 25 x 190 x 115 mmMounting Din rail Symmetrical or asymmetrical

DIN railFront or side position

Power-over-Ethernet (PoE) Class 3 NonePower supply 24 V DC if not using PoE 24 V DC

100-240 V AC/24 V DC adapter supplied

Operating temperature -25 °C to +70°C -30 °C to +80°CHumidity rating 5 % to 95 % relative humidity

(without condensation) at +55 °C

5 % to 95 % relative humidity (without condensation) at +40 °C

Regulatory/standards compliance for electromagnetic interference Emissions (radiated and conducted)

EN 55022/EN 55011/FCC class A

EN 55022/FCC class A

Immunity for industrial environments:

EN 61000-6-2 EN 61000-6-2

- electrostatic discharge EN 61000-4-2 EN 61000-4-2 - radiated RF EN 61000-4-3 EN 61000-4-3 - electrical fast transients EN 61000-4-4 EN 61000-4-4

- surge EN 61000-4-5 EN 61000-4-5 - conducted RF EN 61000-4-6 EN 61000-4-8

- power frequency magnetic field

EN 61000-4-8 EN 61000-4-11

Regulatory/standards compliance for safetyInternational (CB scheme) IEC 60950

USA UL508/UL60950 UL508Canada cUL (complies with CSA C22.2,

no. 60950)cUL (complies with CSA C22.2, no. 14-M91)

Europe EN 60950Australia/New Zealand AS/NZS25 60950

Serial portsNumber of ports 1 2

DB

1009

78

Types of ports RS232 or RS485 (2-wire or 4-wire), depending on settings

COM1: RS485 (2-wire or 4-wire)COM2: RS232 or RS485 (2-wire or 4-wire), depending on settings

Protocol Modbus RTU/ASCIIPowerLogic (SY/MAX)

Modbus RTU/ASCIIPowerLogic (SY/MAX)

Maximum baud rate 38400 or 57600 baud depending on settings

38400 baud

Maximum number of directly connected devices

32 32 per port, 64 in all

Ethernet portNumber of ports 1 2

Types of ports One 10/100 base TX (802.3af) port

One 10/100 base TX portOne 100 base FX port (multimode optic fiber)

Protocol HTTP, SNMP, FTP, Modbus TCP/IP

HTTP, SNMP, SMTP, SNTP, FTP, Modbus TCP/IP

Baud rate 10/100 MB 10/100 MB

Web serverMemory for custom HTML pages

None 16 MB

106

Page 101: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 107 Mardi, 11. avril 2006 4:00 16

Communicationand supervision

EGX100 Ethernet gatewayEGX400 Ethernet server (cont.)

InstallationDIN rail mounting (EGX100)

DB

1092

83

DB

1092

84

Side mounting on DIN rail (EGX400)

DB

1094

32

DB

1009

70

Front mounting on DIN rail (EGX400)

DB

1094

33

DB

1009

72

107

Page 102: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 108 Mardi, 11. avril 2006 4:00 16

Communicationand supervision

WebPageGenerator (WPG) software toolHTML-page generator (EGX400)

PB

1015

60

FunctionVery easy to use, the WebPageGenerator (WPG) software tool generates HTML pages for the EGX400 server. It is used to:b select the devices connected to the serverb transfer the HTML pages corresponding to the selected devices to the server.

The WPG tool can set up HTML pages for the following devices:b Sepam Series 20, Sepam Series 40, Sepam Series 80 and Sepam 2000b Masterpact equipped with Micrologic A, P and H control unitsb Power Meter PM200, PM500, PM700 and PM800b Circuit Monitor Series 3000, 4000 and 4250.

The tool interface is in English, French, and Spanish. However, the tool can be easily adapted to create web pages that support local languages. For more information or to obtain WPG, contact your Schneider Electric representative.

HTML pagesFollowing transfer, the EGX400 contains HTML pages that can be used to remotely monitor equipment under secure conditions. b 1st service level based on the summary pages.b 2nd service level based on specific pages for each type of device.

Summary pagesFive summary pages are available for overall monitoring of the switchboard. They present the main measurements recorded by the devices connected to the server.b Page 1 v 3-phase average rms currentv active powerv power factorb Page 2v rms current per phaseb Page 3v demand current per phaseb Page 4v demand powerv peak powerv time-stamping datab Page 5 v active powerv reactive powerv date and time of last reset of energy meters.

Specific pages for each deviceA number of specific pages present detailed information on each device for in-depth analysis, e.g.:b operating information:v instantaneous current per phasev demand current per phasev active and reactive powerv average voltage (phase-to-neutral and phase-to-phase)v maximum unbalancev power factorv frequencyb event information:v minimum and maximum current valuesv maximum demand currentv date and time of last resetb historical data:v recording over 38 days (at 15-minute interval) of six user-selectable parameters (energy by default), every 5, 15, 30 or 60 minutes, with graphic display and data export to a CSV (Comma Separated Variable) file.

HTML page with summary information on all the equipment in a switchboard.

PB

1015

61

Single device operating information HTML page.

PB

1015

62

Single device HTML page showing historical data.

108

Page 103: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 109 Mardi, 11. avril 2006 4:00 16

109

Page 104: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 110 Mardi, 11. avril 2006 4:00 16

Communicationand supervision

MPS100 Micro Power Server 0

The MPS100 Micro Power Server: b notifies maintenance staff whenany preset alarm or trip is activatedby the Micrologic trip unit, automatically sending an e-mail and/or SMSb data logs are periodically forwardedby e-mailb the e-mails are sent via an Ethernet local area network (LAN) or remotelyvia modem.

Micro Power Server makes data collection easyfor monitoring Masterpact/Compact circuit breakersNow, more than ever, there is a need to monitor electrical distribution systems in industrial and large commercial applications. The key to managing all equipment, maximising efficiencies, reducing costs and increasing up time is having the right tools.Micro Power Server MPS100 is designed to withstand harsh electrical environments and provide a consistent flow of easy to interpret information.

Micro Power Server is designed for unattended operation within the main LV switchboardThe MPS100 is a self-contained facility information server that serves as a stand-alone device for power system monitoring. It is used to transfer power system information via a standard web browser overan Ethernet local area network (LAN) or via modem, making it possible to view power system information on a PC with an Ethernet connection.In either capacity, the Micro Power Server functions as a web server for Micrologic trip unit and Power Meter (PM500) supervision, automatically notifying (e-mailand/or SMS) maintenance staff when any preset alarm or trip is activated inthe Micrologic trip unit.

Benefitsb view your main LV switchboard without installing software on your local PC, eliminating the need for a dedicated PC with specific softwareb Micro Power Server allows centralised monitoring, so you no longer waste precious time walking around the facility to collect datab view your main LV switchboard via a modem connection (GSM or switched network), avoiding the need for a LAN b maintenance people are automatically notified at any time, wherever they are,so you do not have to stay in front of a monitor all day longb data logs can be periodically forwarded by sending e-mails to the relevant people (maintenance, accounting, application service provider) automaticallyb possibility to monitor/notify six external events (limit switches, auxiliary switches PM800 alarm outputs and OF/SDE contacts)b back-up of Micrologic trip unit settings in the memory of the MPS100, so you know where to retrieve it when necessary.

PB

1008

23-4

2P

B10

0804

-60

MPS100 Micro Power Server.

PB

1007

99-6

8

Main LV switchboard.

PB

1008

77-6

7

Monitoring of your main LV switchboard via embedded web pages in the MPS100 accessible with a standard web browser.

110

Page 105: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 111 Mardi, 11. avril 2006 4:00 16

Communicationand supervision

MPS100 Micro Power Server (cont.) 0

Typical architecture

PB

1007

99-3

4

DB

1038

10

It is possible to combine the different types of architecture.

PB

1008

03-1

4

Micrologic trip unit.

PB

1007

08-1

7

Power Meter range.

Supported Modbus devicesb Micrologic trip unitsb Power Meters (PM9, PM500, PM700, PM800...).Maximum recommended connected devices is 10.

Featuresb access to the power system via a standard PC web browserb real-time data displayed with an intuitive and user friendly interface (dashboard)b Ethernet Modbus TCP/IP connectivity directly to the LAN or via modem (Point to Point Protocol services)b SMTP (Simple Mail Transfer Protocol) client (capacity to send e-mail)b local logging of data such as energy, power, current…b set-up and system configuration through MPS100 embedded HTML pagesb user interface translatable in any language, factory settings in English and Frenchb 6 inputs/2 outputs (no-volt contact)b DHCP (Dynamic Host Configuration Protocol) client.

Technical characteristics

PB

1008

05-2

3

Short Message Service (SMS).

Power supply 24 V DC ±15 %, consumption = 250 mAOperating temperature 0 to +50 °CRugged compact metal housing 35 x 218 x 115 mm (H x W x D)

Additional information available at: http://194.2.245.4/mkt/microser.nsfUser name: MPS, Password: MPS100

Part numbers

MPS100 Micro Power Server 33507

Main switchboard at Plaza hotel.Air conditioning breaker tripped on ground fault Ig = 350 A.06:37 on 10/12/2002

111

Page 106: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 112 Mardi, 11. avril 2006 4:00 16

Communication and supervision

SMS software 0

DB

1084

87

PowerLogic® System Manager Software (SMS) is a full featured, web-enabled product family. With standard intuitive views, SMS ensures a consistent power and utility monitoring experience. Upon installation, the system is online and ready to display and record monitored information in a wide variety of predefined views, including over 50 real-time tables, analog meters and bar charts, an alarm log with waveform links, pre-engineered power quality and utility cost reports, and more. You can also tailor SMS to meet your own needs, with customized screens, trends and reports that are automatically incorporated into the tabbed navigational user interface.b Simultaneous remote connections from any browser-equipped computer on your network - no client software required.b Intuitive tabbed interface for quick system navigation.b Real-time data and report sharing with secure access to information.b Remote alarm notification to email, pagers, and other remote devices.b Distributed monitoring and automatic data collection to eliminate nuisance data gaps.b Open system architecture with industry standard protocols and support for a plethora of intelligent monitoring devices.b Modular add-ons for advanced graphics, reports, billing and customized functionality enhancements.

Tables: instantaneous readings.

DB

1084

88

SMS 4.0 Product FamilyThe System Manager 4.0 product family is comprised of three, full-featured software applications designed to meet the power monitoring needs of small-systems, with fewer than sixteen devices, to large, enterprise systems with hundreds of devices.

System Manager DL (SMSDL)b Web-enabled product for small systems.b One browser connection (upgradeable to 6) for local or remote data display.b 16 device limit (upgradeabe to 32).b 2 Gigabyte MSDE database.b Information Manager reports.

System Manager Standard (SMSSE)b Intermediate level product for intermediate systems (typically 64 or fewer devices).b One browser connection (upgradeable to 6) for local or remote data display.b Unlimited devices.b 2 Gigabyte MSDE database.b Information Manager reports.

System Manager Professional (SMSPE)b Enterprise level product for large systems.b 10 simultaneous browser connections.b Local and remote system and device setup.b Unlimited devices.b SMS Advanced Reports for web-based viewing and creation of reports.b SQL Server 2000 database (no size constraint).

Bar charts: load phase currents.

DB

1084

89

Historical: data trend report.

Part numbersCore Software Products

System Manager DL 4.0 (16 device support; 1 browser client; 2 Gbytes data storage)

SMSDL

E87

265

System Manager standard 4.0 (no device limit; 1 browser client; 2 Gbytes data storage)

SMSSE

System Manager Professional 4.0 (no device limit; 10 browser clients; unlimited data storage)

SMSPE

Add-on ProductsWeb-based interactive graphics add-on for SMS 4.0 GFXv4OPC server application for SMS 4.0 SMSOPCEnterprise receive add-on for SMS-3000 (1) SMSRXAdvanced reports add-on for SMSSE (2) SMSADVRPTS

Extension ProductsAdds five additional web client connections to SMSDL, SMSSE and SMSPE SMSWebXTRExtends SMSDL device limit to 32 SMSDL32UConverts SMSDL to SMSSE SMSDL2SEConverts SMSSE to SMSPE (2) SMSSE2PE(1) Contact your local Schneider Electric office for availability of SMSRX product for SMS 4.0.(2) Contact your local Schneider Electric office for availability.Alarms.

112

Page 107: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 113 Mardi, 11. avril 2006 4:00 16

Communication and supervision

SMS software (cont.) 0

DB

1084

91

FunctionsSMS offers a wide range of functions:b simple pre-configured functions:v data tablesv meters and bar chartsv historical logging and trendingv display of waveformsv harmonic analysisv event loggingv min/max resettingv controlv device setupb advanced functions that the users can customise:v user-defined tables and reportsv setup of automatic tasksv graphic interface customised via the GFX option.

Data tables, meters and bar chartsSMS can supply a wide range of measurements in real time via tables, bar charts or meters.SMS is pre-configured to accept and display the data supplied by the devices.Users can also create their own customised tables.Simply select one or more devices, the desired measurements, and the table is created automatically.

Historical logging and trendingSMS automatically saves the data from the devices to a central data base.The data can be retrieved, displayed or printed as tables, trend curves or reports.

Waveform display and harmonic analysisThe data is presented in graphs.The current and voltage waveforms may be viewed simultaneously or individually, and can be printed.If the waveform capture is over four cycles, it is possible to display the percentage of each harmonic order and the total harmonic distortion (THD).

Event loggingSMS logs all events including alarms.Events may be of any type, from power outages to configuration changes.All user action on the system is recorded and can be displayed, printed or deleted at all times.For each event, the following fields are displayed on the screen:b deviceb date and timeb type of eventb user name.This make it possible to recover all the necessary information for system diagnostics.

SMS can be used to link alarms to digital and analog inputs in addition to those that can be set up directly on certain devices.User-set values can be used as alarm conditions.The alarm parameters can be set with a number of security levels.Each level corresponds to audio and visible indications, a password and actions.Each level can be set up with different sounds, colours, actions, etc.

Management of user rightsSMS can handle an unlimited number of users, each with their own name and password.In addition, SMS manages different levels of user rights to restrict access to strategic functions.

ControlSMS can be used to control devices (e.g. opening and closing of circuit breakers).To avoid accidental and unauthorised use, only users with appropriate rights can access this function.SMS can also be used to reset min/max values stored in the devices.

Tables: fundamental phasor readings.

DB

1084

92

Meters: analog meters.

DB

1084

93

Historical: electrical cost summary.

DB

1084

94

Historical: disturbance capture.

113

Page 108: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 114 Mardi, 11. avril 2006 4:00 16

Communication and supervision

SMS software (cont.) 0

DB

1084

95

Creation of custom reportsSMS can be used to create reports from all types of data, including real-time values.SMS can use standard or user-customised report formats.These reports can be saved in HTML format for (display via a Web browser, use and formatting with Excel).

Automatic tasksThe available tasks include launching programs, resetting devices, sending e-mail, data acquisition and waveform capture.A task may be launched when an alarm is detected or at a precise time set by the user.

Animated graphics via the GFX optionThe GFX interactive graphics option offers a wide range of presentations, including single-line diagrams, electrical switchboards and site and building diagrams.GFX offers complete customisation functions for these graphic presentations.

Organisation in groupsThe devices can be organised in groups which makes it possible to select them according to function or the organisation of the electrical-distribution system.This function makes it possible to logically structure the devices and data, e.g. by building, by voltage level, by function, etc.

Device setup, example of a Circuit MonitorSimple devices may be set up on their front panel.For devices with advanced functions, local setup is difficult and even impossible for some functions.Software greatly facilitates device setup.

OPC optionSMS integrates data from building automation and other systems via the OPC options.

Help systemSMS comprises a complete, on-line help system that takes into account the screen where help is needed.The help is divided into chapters that may be printed. Most of the configuration dialog boxes include a help button offering direct access to the information on the concerned dialog.

Diagrams: single-line diagram and device summary.

DB

1084

96

Diagrams: building diagram.

DB

1084

97

System: documentation and links.

114

Page 109: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 115 Mardi, 11. avril 2006 4:00 16

Communication and supervision

SMS software (cont.) 0

r

Selection guideProducts features SMSDL SMSSE SMSPEDevices

System Support: PowerLogic and Modbus™ /Modbus TCP compatible devices

b b b

Number of device conections 16 (up to 32 with SMSDL32U)

Virtually unlimited

Virtually unlimited

System and device setup: PowerLogic metering and monitoring devices

Local Local Local and remote

Data acquisitionDatabase MSDE MSDE

(SQL Personal Editionwith SMSAD-VRPTS) (1)

SQL Server

Data storage limit 2 Gbytes 2 Gbytes (unlimited with SMSAD-VRPTS) (1)

Unlimited

Automatic onboard file upload b b bWeb-Enabled Monitoring

Pre-defined meters, tables and bar chart real time displays

b b b

Real time trend, trending/forecasting and power quality pass//fail analysis

b b b

Historical trending and pre-defined reports b b bAlarm notification with disturbance direction detection

b b b

Waveform capture analysis-transient detection, disturbance, FFT, RMS

b b b

Viewing and emailing pre-defined and user-defined reports

b b b

Report creation and scheduling Local Local (remotewith SMSAD-VRPTS) (1)

Local and remote

Control outputs Local Local Local and remote

Add-on productsExtension of SMSDL to 32 devices connections (with SMSDL32U)

Add-on - -

Advanced reports (1) (with SMSADVRPTS) - Add-on bExtra Web client: five additional connections (with WEBXTR)

Add-on Add-on -

Interactive graphics (with GFXv4) Add-on Add-on Add-onOPC server for SMS 4.0 (with SMSOPC) Add-on Add-on Add-onConverts SMSDL to SMSSE (with SMSDL2SE) Add-on - -

Converts SMSSE to SMSPE (1) (with SMSSE2PE) - Add-on -

Web-enabledSecure login to protect information misuse b b bNo training required, browser interface - provides access information remotely through any computer with network access

b b b

Full featured viewing capabilities with simultaneous browser connections

1 (up to 6 with WEBXTR)

1 (up to 6 with WEBXTR)

10 (2)

(1) Contact your local Schneider Electric office for availability.(2) Licensed for 10 browser connections. Additional licenses can be purchased. SMSPE has been tested for 30 simultaneous browser connections.

115

Page 110: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

ART10934.book Page 116 Mardi, 11. avril 2006 4:00 16

116

Page 111: ART10934.book Page 1 Mardi, 11. avril 2006 4:00 16

Schneider Electric Industries SAS89, boulevard Franklin RooseveltF - 92500 Rueil-Malmaison (France)Tel : +33 (0)1 41 29 85 00

http://www.schneider-electric.comhttp://www.merlin-gerin.com

As standards, specifications and designs change from time to time, please ask for confirmation of the information given in this publication.

Printed on recycled paper.

Design: Schneider ElectricPhotos: Schneider ElectricPrinted: Imprimerie du Pont de Claix/JPF - made in France

04-2006ABTED201151EN

AR

T.1

0934

© 2

006

Sch

neid

er E

lect

ric -

All

right

s re

serv

ed

432E0000_Ver3.1.fm Page 1 Mardi, 11. avril 2006 4:20 16