(page 1 of 1)(sw 7510 chauteau brown) flush w/ curb sidewalk lvl 0'-0" 7' alternating...

1
BIKE LANE PARKING LANE ws ws PUBLIC ALLEY ws FE 103'-7 1 2 " 96' (8) 5' BAYS + (8) 7' BAYS = 48 SEATS 7'-6" 63'-7 1 2 " 56' 8 BAYS = 32 SEATS 7'-6" Q STREET NW 14TH STREET NW 14TH STREET NW Q STREET NW (2) 7' BAYS @ CENTER 5' BAY 7' BAY ALTERNATING 5' & 7' BAY 4' HEATER SHED 7' BAY 4' HEATER SHED 7' BAY LE DIPLOMATE INTERIOR NOT IN SCOPE LE DIPLOMATE INTERIOR NOT IN SCOPE EXG. PATIO NOT IN SCOPE 6' CLR. 6' CLR. PREVIOUSLY APPROVED SIDEWALK DINING 03 A101 05 A101 GENERAL NOTES: 1. PROVIDE ONE (1) 120V, 20 AMP DIMMING CIRCUIT AT EACH PAVILION FOR CAFE LIGHTING. 2. PROVIDE ONE (1) 120V, 20 AMP CIRCUIT AT EACH PAVILION FOR HEATING UNIT. 3. ELECTRIC LINES TO BE RUN FROM RESTAURANT IN OVERHEAD EXTERIOR RATED 'SEAL TIGHT' CONDUIT INTO HEATER SHED 4. PROVIDE ONE (1) 100# PROPANE TANK & TYPE 2A:10B:C FIRE EXTINGUISHER AT EACH HEATER SHED. 5. PROVIDE 1HR RATED WALL ASSEMBLY (SEE DTL) SEPARATING HEATER & FUEL TAKE W/I HEATER SHED 'SEAL TIGHT' ELECTRICAL CONDUIT ABOVE 'SEAL TIGHT' ELECTRICAL CONDUIT ABOVE PLEXI GLASS WINDOW PANEL 5' ALTERNATING BAY 4X4 POST 2X6 DECK BOARD (SW 7510 CHAUTEAU BROWN) FLUSH W/ CURB SIDEWALK LVL 0'-0" 7' ALTERNATING BAY 09 A101 07 A101 EDGE OF CURB T.O. SILL + 3'-0" T.O. POSTS + 8'-0" 4X4 POST PVC TRIM (SW7757 HIGH. REFLECT. WHITE) EXHAUST PIPE, PNT. PVC SILL (PNT) 3/8 PLYWOOD BEADBOARD PANEL (SW6509 GEORGIA BLUE) TUFTEX ROOF PANEL 06 A101 EQ.1 EQ.1 EQ.2 2x4 STUD WALL W/ PVC SILL PLEXIGLASS WINDOW PANEL W/ DECORATIVE CORNER STOPS EQ.1 EQ.1 EQ.2 EQ.2 2X4 WINDOW PANEL MULLION 2X4 WINDOW PANEL MULLION 7'-6" HEATER SHED 4' HEATER SHED 100# PROPANE TANK-16"Ø HEATING UNIT 2X6 PLATFORM EQ.2 EQ.2 EQ.2 3' 3'-8 1 2 " ACCESS PANEL / DOOR 1A - 1HR RATE SHED ENCLOSURE 3/8 PLYWOOD BEADBOARD PANEL (SW6509 GEORGIA BLUE) PVC TRIM (SW7757 HIGH. REFLECT. WHITE) 5' ALTERNATING BAY 7' TYP. Q. ST. BAY EQ. EQ. EQ. EQ. EQ. EQ. 7' TYP. Q. ST. BAY 2'-1" 2'-1" 2'-1" 5' ALTERNATING BAY 7' ALTERNATING BAY 2'-3" 2'-3" 5' ALTERNATING BAY 3' 3'-8 1 2 " 2'-1" 2'-1" 2'-1" 7'-6" HEATER SHED 4' HEATER SHED CHASE WALL BELOW W/ SILL PLYWOOD & MEMBRANE SHED ROOF 04 A101 08 A101 DUCT CHASE W/ SILL EQ. EQ. EQ. EQ. EQ. EQ. 7' TYP. Q. ST. BAY 7' TYP. Q. ST. BAY 2x4 STUD WALL W/ PVC SILL 2X4 WINDOW PANEL MULLION CHASE WALL BELOW W/ SILL ACCESS PANEL / DOOR FE FE 1A 1A 2x4 STUD WALL BTWN 4X4 POST PVC TRIM (PNT) PVC SILL (PNTD) PT 2x PLATFORM T.O. SILL +3'-0" 2X6 DECK BOARD (PNT) ON 2X PLATFORM PLEXIGLASS WINDOW PANEL W/ CNC'D PLYWOOD GRILLE PVC TRIM (PNTD) 3/8 PLYWOOD BEAD BRD. INT. TYP. 2X6 RAFTER & BLOCKING 2X6 CONT. EAVE LEDGER (PNT) 2X4 EAVE BLOCKING 7' 8'-7 1 4 " 3' GLOBE FIXT. BY OWNER, CNTR IN BAY 1X HEAD TRIM TUFTEX ROOF PANEL 6'-7 1 2 " SHED ROOF: 3/4" PLYWOOD W/ ROOFING MEMBRANE ON 2X FRAMING HEATING UNIT 3/8 PLYWOOD BEAD BRD. EXHAUST PIPE (PNT) TO CLR. HEIGHT OF ROOF T.O. POST + 8'-0" 2X4 SHED ENCLOSURE W/ EXT. PLYWOOD CLADDING 7'-4 1 2 " 1" MFD CORBEL (PNT) CNTR ON 4X4 7' TYP. BAY 2X6 & PLYWOOD VALANCE EAVE PVC TRIM 2X6 DECK BOARD (PNT) 3'-7 1 2 " WINDOW 2'-1" WINDOW 2'-1" WINDOW CURB TUFTEXT ROOF PANEL 4x4 POST 1X FURRING AS REQ'D SIDEWALK LVL 0'-0" 3' 2X6 RAFTER, SLOPED EQ. EQ. SCALLOPED SCRIBED PLYWOOD FASCIA 2'-1" WINDOW 2x4 WINDOW MULLION EXT PLYWOOD PANEL 3/8 PLYWOOD BEAD BRD. CONT. ON FACE OF 4X4 CONT. 2X8 RAFTER LEDGER 2X6 HEADER 4X4 POST 2X4 PARTITION WALL EQ. EQ. EQ. PLEXIGLASS WINDOW W/ CORNER WEDGE 3'-8" WINDOW 2X4 HEADER FRAMING BTWN & JUSTIFIED TO OUTSIDE OF 4X4 12:1/2 PLYWOOD & MEMBRANE SHED ROOF PVC TRIM (PNT) PVC TRIM (PNT) PVC TRIM (PNT) 3/8 PLYWOOD BEAD BOARD PANEL (PNT) TUFTEX ROOF PANEL 1" MFD CORBEL (PNT) 2X4 TOP PLATE & RAFTER BLOCKING DUCT & DIFFUSER CHASE WALL FRAMING W/ WOOD SILL PVC TRIM SOLID PLYWOOD PANEL (PNT) 12:1/2 7'-11 3 4 " 6'-5 3 4 " 12:1/2 DIFFUSER CNTR ON WALL GLOBE FIXT. CNTR OVER TABLE 2x4 WINDOW MULLION PVC SILL LINE (DASHED) OF APPROXIMATE EXTENTS OF PAINTED BRAND SIGNAGE SCONCE FIXTURE 2'-9" 2' 5' 3'-2 1 2 " 5' 2'-1" 2'-1" GWB & WOOD WALL ASSEMBLY - RATED 1A U314 - 1HR CONSTRUCTION ITEM 1: 2X4 STUD @ 16" O.C. ITEM 2: 5/8" GWB TYPE X. EA.SIDE (SEE UL ASSEMBLY) 2 NOTE: ASSEMBLY TO ATTACH TO UNDERSIDE OF ROOF / DECK (SEE UL ASSEMBLY & GENERAL PARTITION NOTES) 1 2 4 3 4 " 16" O.C. MIN. SOLID PLEXIGLASS PANEL 1" CNC'D WOOD CORNER WEDGE (SW7757) 1" SITE INSTALLED PERIMETER STOP TRIM (SW7757) SEE ELEVATIONS 3'-7 1 2 " 2x4 MULLION (SW7757) 7" 7" 2" 2" R2" PAINT SCHEDULE COLOR LOCATION SW7510 - CHAUTEAU BROWN DECK BOARDS SW6509 - GEORGIA BLUE BEAD BOARD (INT & EXT) SW7757 - HIGH REFLECTIVE WHITE TRIMS, SILLS, WINDOW STOPS & MULLIONS ROOF FRAMING SW6608 - RAVE RED SCALLOPED VALANCE PVC SILL (SW7757) 2x4 HEAD JAMB (SW7757) MDF EAVE CORBEL (SW7757) HEAD TRIM / PLYWOOD BEYOND (SW6509) 1/2" PLYWOOD VALANCE & TRIM BAND (SW6608) UPPER EAVE FASCIA (SW7757) 6 1 4 " 4" 1" 5 1 2 " 1 1 2 " 1' ALL DIMENSIONS AND RELATIONSHIPS MUST BE VERIFIED BY CONTRACTOR. THE ARCHITECT IS TO BE NOTIFIED OF ANY DISCREPANCIES BEFORE PROCEEDING WITH THE CONSTRUCTION. DO NOT SCALE FROM DRAWINGS. 1601 14th St NW, Washington, DC 20009 SCALE: DATE: DRAWN: FILENAME: DRAWING TITLE REVISIONS MARK DATE CHECKED: SEAL OWNER/ OPERATOR ARCHITECT STOKES ARCHITECTURE 1700 SANSOM STREET 12TH FLR. PHILADELPHIA, PA 19103 PH: 215.523.9190 FX: 215.523.9398 PARC DEUX RESTAURANT PARTNERS, LLC 1601 14TH ST NW WASHINGTON, DC 20009 le diplomate covid-19 seating-parlket.dwg ---- 12/23/16 le Diplomate parklet pavilions streatery winter ready grant program RAS Richard Stokes DC License 101812 PERMIT SUBMISSION parklet pavilion & outdoor dining A101 BUILDING INFORMATION & CODE REVIEW PROJECT TITLE: LE DIPLOMATE- PARKLET PAVILION PROJECT ADDRESS: 1601 14th St NW, Washington, DC 20009 APPLICABLE CODES: - 2017 DISTRICT OF COLUMBIA BUILDING CODE - 2017 DC CONSTRUCTION CODE(S) - 2017 DC PLUMBING CODE - 2017 DC MECHANICAL CODE - 2017 DC FUEL GAS CODE - 2017 DC ELECTRICAL CODE PROJECT DESCRIPTION: TEMPORARY WOODEN PARKLET PAVILION IN ACCORDANCE WITH THE 'STREATERY WINTER READY GRANT PROGRAM' OF THE DISTRICT OF COLUMBIA. USE / OCCUPANCY CLASSIFICATION ASSEMBLY: A-2 USE / FLOOR AREAS / OCCUPANT LOADS (TABLE 1004.1.2): FLOOR / LEVEL CLASSIFICATION / FUNCTION OCCUPANCY LOAD FACTORS: SQUARE FOOTAGE: ALLOWABLE OCCUPANCY: 1ST FLOOR: ASSEMBLY - DINING (OUTDOOR) N/A OUTDOOR 780 SF (14TH ST PARKLET) 480 SF (Q ST SIDEWALK) 48 ACTUAL 32 ACTUAL TOTAL: 80 4 ACCESSIBLE SEATS REQ'D @ 5% CONSTRUCTION INFORMATION CONSTRUCTION TYPE: 5B (EXISTING NO CHANGE) REQ'D SEPARATION OF OCCUPANCY N/A (EXISTING NO CHANGE) (PER SECTION 508.4) SPRINKLER N/A FIRE / SMOKE ALARM N/A BUILDING STATISTICS ALLOWABLE / PERMITTED SRINKLER ADJUSTMENT ACTUAL / PROPOSED HEIGHT (FEET) TABLE 504.3 B / M: 55' N/A 8'-8" HEIGHT (STORIES) TABLE 504.4 B / M: 3 N/A 1 AREA (SQ.FT. / STORY) TABLE 506.2 B / M: 19,000 / 12,500 N/A 780 SF (14TH ST PARKLET) 480 SF (Q ST SIDEWALK) LOCATION PLAN PLAN - Q STREET PARKLET 3/32" = 1'-0" 01 A101 PLAN - 14TH STREET PARKLET 3/32" = 1'-0" 02 A101 PARTIAL PLAN - 14TH ST. PAVILION END 1/4" = 1'-0" 05 A101 PARTIAL ELEVATION - 14TH ST. PAVILION END 1/4" = 1'-0" 06 A101 PARTIAL ELEVATION - Q ST. PAVILION END 1/4" = 1'-0" 04 A101 SECTION - TYP. PAVILION BAY 1/2" = 1'-0" 08 A101 SECTION - PAVILION END CAP / HEATER SHED 1/2" = 1'-0" 09 A101 ELEVATION - TYP. END CAP / SHED 1/2" = 1'-0" 07 A101 DETAIL - TYP. WINDOW PANEL 1" = 1'-0" 10 A101 PARTIAL PLAN - Q ST. PAVILION END 1/4" = 1'-0" 03 A101 DRAWING INDEX PERMIT CD SET REVISION 1 A101 PARKLET PAVILION & OUTDOOR DINING A102 ELECTRICAL PLAN & CUT SHEETS B2102335 Fire Review - Wayne Ferguson - 12-11-2020 Electrical Review - Wayne Ferguson - 12-11-2020 Structural Review - Wayne Ferguson - 12-11-2020 HPRB Review - Steve Callcott - 12-11-2020 12/11/20 (Page 1 of 1)

Upload: others

Post on 24-Jan-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: (Page 1 of 1)(SW 7510 CHAUTEAU BROWN) FLUSH W/ CURB SIDEWALK LVL 0'-0" 7' ALTERNATING BAY 09 A101 07 A101 EDGE OF CURB T.O. SILL + 3'-0" T.O. POSTS + 8'-0" …

BIKE LANE

PARKINGLANE

ws

ws

PU

BLIC

ALLEY

ws

FE

103'-71 2"

96'

(8) 5' BAYS + (8) 7' BAYS = 48 SEATS

7'-6

"

63'-71 2"

56'

8 BAYS = 32 SEATS7'

-6"

Q STREET NW

14TH STREET NW

14TH S

TR

EET N

W

Q S

TR

EET N

W

(2) 7' BAYS @ CENTER

5'

BAY7'

BAY

ALTERNATING

5' & 7' BAY

4'

HEATER SHED

7'BAY

4'

HEATER SHED

7'BAY

LE DIPLOMATE INTERIOR NOT IN SCOPE

LE DIPLOMATE INTERIOR NOT IN SCOPE

EXG. PATIO NOT IN SCOPE

6'

CLR

.

6'

CLR

.

PREVIOUSLY APPROVED SIDEWALK DINING

03A101

05A101

GENERAL NOTES:

1. PROVIDE ONE (1) 120V, 20 AMP DIMMING CIRCUIT ATEACH PAVILION FOR CAFE LIGHTING.

2. PROVIDE ONE (1) 120V, 20 AMP CIRCUIT AT EACH

PAVILION FOR HEATING UNIT.3. ELECTRIC LINES TO BE RUN FROM RESTAURANT IN

OVERHEAD EXTERIOR RATED 'SEAL TIGHT' CONDUIT

INTO HEATER SHED

4. PROVIDE ONE (1) 100# PROPANE TANK & TYPE2A:10B:C FIRE EXTINGUISHER AT EACH HEATER SHED.

5. PROVIDE 1HR RATED WALL ASSEMBLY (SEE DTL)

SEPARATING HEATER & FUEL TAKE W/I HEATER SHED'SEAL TIGHT'ELECTRICAL

CONDUIT ABOVE

'SEAL TIGHT'ELECTRICAL

CONDUIT ABOVEPLEXI GLASS

WINDOW PANEL

5'

ALTERNATING BAY

4X4 POST

2X6 DECK BOARD

(SW 7510 CHAUTEAU BROWN)

FLUSH W/ CURB

SIDEWALK LVL

0'-0"

7'ALTERNATING BAY

09A101

07A101

EDGE OF CURB

T.O. SILL

+ 3'-0"

T.O. POSTS

+ 8'-0"

4X4 POST

PVC TRIM

(SW7757 HIGH. REFLECT.WHITE)

EXHAUST PIPE, PNT.

PVC SILL (PNT)

3/8 PLYWOOD

BEADBOARD PANEL

(SW6509 GEORGIA BLUE)

TUFTEX ROOF PANEL

06A101

EQ.1 EQ.1 EQ.2

2x4 STUD WALL

W/ PVC SILL

PLEXIGLASS WINDOW

PANEL W/ DECORATIVE

CORNER STOPS

EQ.1 EQ.1

EQ.2 EQ.2

2X4 WINDOW

PANEL MULLION

2X4 WINDOW PANEL

MULLION

7'-6

"

HEATER

SHED

4'HEATER SHED

100# PROPANE

TANK-16"Ø

HEATING UNIT

2X6 PLATFORM

EQ.2 EQ.2 EQ.2

3'

3'-8

12"

ACCESS PANEL / DOOR

1A - 1HR RATE SHED

ENCLOSURE

3/8 PLYWOOD BEADBOARDPANEL

(SW6509 GEORGIA BLUE)

PVC TRIM(SW7757 HIGH. REFLECT.

WHITE)

5'

ALTERNATING BAY

7'TYP. Q. ST. BAY

EQ.EQ. EQ.EQ. EQ. EQ.

7'TYP. Q. ST. BAY

2'-1"2'-1" 2'-1"

5'

ALTERNATING BAY7'

ALTERNATING BAY

2'-3" 2'-3"

5'

ALTERNATING BAY

3'

3'-8

12"

2'-1"2'-1" 2'-1"

7'-6

"

HEATER

SHED

4'HEATER SHED

CHASE WALL BELOWW/ SILL

PLYWOOD &MEMBRANE

SHED ROOF

04A101

08A101

DUCT CHASEW/ SILL

EQ. EQ.EQ.EQ. EQ.EQ.

7'TYP. Q. ST. BAY

7'TYP. Q. ST. BAY

2x4 STUD WALL

W/ PVC SILL

2X4 WINDOW

PANEL MULLION

CHASE WALL BELOWW/ SILL

ACCESS PANEL / DOOR

FEFE

1A

1A

2x4 STUD WALL BTWN 4X4 POST

PVC TRIM (PNT)

PVC SILL (PNTD)

PT 2x PLATFORM

T.O. SILL

+3'-0"

2X6 DECK BOARD (PNT)

ON 2X PLATFORM

PLEXIGLASS WINDOW PANEL W/

CNC'D PLYWOOD GRILLE

PVC TRIM (PNTD)

3/8 PLYWOOD BEADBRD. INT. TYP.

2X6 RAFTER & BLOCKING

2X6 CONT. EAVE LEDGER(PNT)

2X4 EAVE BLOCKING

7'

8'-7

14"

3'

GLOBE FIXT. BY

OWNER, CNTR IN BAY

1X HEAD TRIM

TUFTEX ROOF PANEL

6'-7

12"

SHED ROOF: 3/4" PLYWOOD W/

ROOFING MEMBRANE ON 2X FRAMING

HEATING UNIT

3/8 PLYWOOD BEAD BRD.

EXHAUST PIPE (PNT) TOCLR. HEIGHT OF ROOF

T.O. POST

+ 8'-0"

2X4 SHED ENCLOSURE

W/ EXT. PLYWOOD

CLADDING

7'-41 2"

1" MFD CORBEL (PNT)

CNTR ON 4X4

7'TYP. BAY

2X6 & PLYWOOD VALANCE EAVE

PVC TRIM

2X6 DECK BOARD (PNT)

3'-7

12"

WIN

DO

W2'-1"

WINDOW2'-1"

WINDOW

CURB

TUFTEXT ROOF PANEL

4x4 POST

1X FURRING AS REQ'D

SIDEWALK LVL

0'-0"

3'

2X6 RAFTER, SLOPED

EQ. EQ.

SCALLOPED SCRIBED

PLYWOOD FASCIA

2'-1"WINDOW

2x4 WINDOW MULLION

EXT PLYWOOD PANEL

3/8 PLYWOOD BEAD BRD.

CONT. ON FACE OF 4X4

CONT. 2X8 RAFTERLEDGER

2X6 HEADER

4X4 POST

2X4 PARTITION WALL

EQ. EQ. EQ.

PLEXIGLASS WINDOW

W/ CORNER WEDGE

3'-8

"

WIN

DO

W

2X4 HEADER FRAMING

BTWN & JUSTIFIED TOOUTSIDE OF 4X4

12:1/2

PLYWOOD & MEMBRANE

SHED ROOF

PVC TRIM

(PNT)

PVC TRIM

(PNT)PVC TRIM (PNT)

3/8 PLYWOOD BEAD

BOARD PANEL (PNT)

TUFTEX ROOF PANEL

1" MFD CORBEL (PNT)

2X4 TOP PLATE &

RAFTER BLOCKING

DUCT & DIFFUSER

CHASE WALL FRAMING W/

WOOD SILL

PVC TRIM

SOLID PLYWOOD PANEL

(PNT)

12:1/2

7'-1

134"

6'-5

34"

12:1/2

DIFFUSER CNTR ONWALL

GLOBE FIXT. CNTR

OVER TABLE

2x4 WINDOWMULLION

PVC SILL

LINE (DASHED) OF

APPROXIMATE EXTENTS OF

PAINTED BRAND SIGNAGE

SCONCE FIXTURE

2'-9

" 2'

5'

3'-21 2"

5'

2'-1" 2'-1"

GWB & WOOD WALL ASSEMBLY - RATED1A U314 - 1HR

CONSTRUCTION

ITEM 1: 2X4 STUD @ 16"O.C.

ITEM 2: 5/8" GWB TYPE X.EA.SIDE(SEE UL ASSEMBLY)

2

NOTE: ASSEMBLY TO ATTACH TO UNDERSIDE OF ROOF / DECK (SEE UL ASSEMBLY& GENERAL PARTITION NOTES)

1

2

434"

16" O.C. MIN.

SOLID PLEXIGLASSPANEL

1" CNC'D WOOD CORNERWEDGE (SW7757)

1" SITE INSTALLEDPERIMETER STOP TRIM(SW7757)

SEE ELEVATIONS

3'-7

12"

2x4 MULLION (SW7757)

7"

7"

2"

2"

R2"

PAINT SCHEDULE

COLOR LOCATIONSW7510 - CHAUTEAU BROWN DECK BOARDSSW6509 - GEORGIA BLUE BEAD BOARD (INT & EXT)SW7757 - HIGH REFLECTIVE WHITE TRIMS, SILLS, WINDOW

STOPS & MULLIONSROOF FRAMING

SW6608 - RAVE RED SCALLOPED VALANCE

PVC SILL (SW7757)

2x4 HEAD JAMB (SW7757)

MDF EAVE CORBEL(SW7757)

HEAD TRIM / PLYWOOD

BEYOND (SW6509)

1/2" PLYWOOD VALANCE& TRIM BAND (SW6608)

UPPER EAVE FASCIA(SW7757)

614"

4"

1" 512"

112"

1 '

ALL DIMENSIONS AND RELATIONSHIPS MUST BE VERIFIED BY CONTRACTOR.THE ARCHITECT IS TO BE NOTIFIED OF ANY DISCREPANCIES BEFORE

PROCEEDING WITH THE CONSTRUCTION. DO NOT SCALE FROM DRAWINGS.

1601 14th St NW, Washington, DC 20009

SCALE:

DATE:

DRAWN:

FILENAME:

DRAWING TITLE

REVISIONSMARK DATE

CHECKED:

SEAL

OWNER/ OPERATOR

ARCHITECTSTOKES ARCHITECTURE1700 SANSOM STREET 12TH FLR.

PHILADELPHIA, PA 19103PH: 215.523.9190FX: 215.523.9398

PARC DEUX RESTAURANTPARTNERS, LLC

1601 14TH ST NWWASHINGTON, DC 20009

le diplomate covid-19 seating-parlket.dwg

----

12/23/16

le Diplomate

parklet pavilions

streatery winter ready grant program

RAS

Richard Stokes DC License 101812

PERMIT SUBMISSION

parklet pavilion &

outdoor dining

A101

BUILDING INFORMATION & CODE REVIEWPROJECT TITLE: LE DIPLOMATE- PARKLET PAVILION

PROJECT ADDRESS: 1601 14th St NW, Washington, DC 20009

APPLICABLE CODES: - 2017 DISTRICT OF COLUMBIA BUILDING CODE

- 2017 DC CONSTRUCTION CODE(S)

- 2017 DC PLUMBING CODE

- 2017 DC MECHANICAL CODE

- 2017 DC FUEL GAS CODE

- 2017 DC ELECTRICAL CODE

PROJECT

DESCRIPTION:

TEMPORARY WOODEN PARKLET PAVILION IN ACCORDANCE WITH THE 'STREATERY WINTER READY GRANT PROGRAM' OF THE

DISTRICT OF COLUMBIA.

USE / OCCUPANCY

CLASSIFICATION

ASSEMBLY: A-2

USE / FLOOR AREAS / OCCUPANT LOADS (TABLE 1004.1.2):

FLOOR / LEVEL CLASSIFICATION / FUNCTION OCCUPANCY LOAD FACTORS: SQUARE FOOTAGE: ALLOWABLE OCCUPANCY:

1ST FLOOR: ASSEMBLY - DINING

(OUTDOOR) N/A OUTDOOR 780 SF (14TH ST PARKLET)

480 SF (Q ST SIDEWALK)

48 ACTUAL

32 ACTUAL

TOTAL: 804 ACCESSIBLE SEATS REQ'D @

5%

CONSTRUCTION INFORMATION

CONSTRUCTION TYPE: 5B (EXISTING NO CHANGE)

REQ'D SEPARATION OF

OCCUPANCY

N/A (EXISTING NO CHANGE) (PER SECTION 508.4)

SPRINKLER N/A

FIRE / SMOKE ALARM N/A

BUILDING STATISTICS

ALLOWABLE / PERMITTED SRINKLER ADJUSTMENT ACTUAL / PROPOSED

HEIGHT (FEET)TABLE 504.3

B / M: 55' N/A 8'-8"

HEIGHT (STORIES)TABLE 504.4

B / M: 3 N/A 1

AREA (SQ.FT. / STORY)TABLE 506.2

B / M: 19,000 / 12,500 N/A 780 SF (14TH ST PARKLET)

480 SF (Q ST SIDEWALK)

LOCATION PLAN

PLAN - Q STREET PARKLET3/32" = 1'-0"

01A101

PLAN - 14TH STREET PARKLET3/32" = 1'-0"

02A101

PARTIAL PLAN - 14TH ST. PAVILION END1/4" = 1'-0"

05A101

PARTIAL ELEVATION - 14TH ST. PAVILION END1/4" = 1'-0"

06A101

PARTIAL ELEVATION - Q ST. PAVILION END1/4" = 1'-0"

04A101

SECTION - TYP. PAVILION BAY1/2" = 1'-0"

08A101

SECTION - PAVILION END CAP / HEATER SHED1/2" = 1'-0"

09A101

ELEVATION - TYP. END CAP / SHED 1/2" = 1'-0"

07A101

DETAIL - TYP. WINDOW PANEL1" = 1'-0"

10A101

PARTIAL PLAN - Q ST. PAVILION END1/4" = 1'-0"

03A101

DRAWING INDEXPERMIT CD SET REVISION 1

A101 PARKLET PAVILION & OUTDOOR DINING •

A102 ELECTRICAL PLAN & CUT SHEETS •

B2102335

Fire Review - Wayne Ferguson - 12-11-2020 Electrical Review - Wayne Ferguson - 12-11-2020 Structural Review - Wayne Ferguson - 12-11-2020 HPRB Review - Steve Callcott - 12-11-2020

12/11/20

(Page 1 of 1)