panelboards & motor starters dpe series: distribution ... small motors and similar electrical...

5
386 Visit our website at www.egsatx.com or www.appletonelec.com or contact us at +33.3.22.54.27.54. © September 2009 ATX Product Catalog PANELBOARDS & MOTOR STARTERS 12 Circuit Version Compliance Data: ATEX - IECEx: Zone 1 & 2 – 21 & 22 ATEX II 2 GD IECEx CE Ex de IIC T6 to T4 Ex tD A21 T80°C to T130°C IP66 – IK10 Operating Temperature: -20°C to +55°C, -40ºC to +55º (optional) Electrical Data: Voltage Amperage Frequency Up to 440 V Up to 160 A 50/60 Hz Panelboards & Motor Starters DPE Series: Distribution Panelboard – Increased Safety Zone 1 & 2 - 21 & 22 II 2 GD ATEX / IEC IP66 - IK10

Upload: haphuc

Post on 23-May-2018

213 views

Category:

Documents


0 download

TRANSCRIPT

386Visit our website at www.egsatx.com or www.appletonelec.com or contact us at +33.3.22.54.27.54. © September 2009

ATX Product Catalog

pAnelBoArds & MoTor sTArTers

12 Circuit Version

Compliance Data:ATEX - IECEx:

Zone 1 & 2 – 21 & 22 ATEX II 2 GD IECEx CE

Ex de IIC T6 to T4 Ex tD A21 T80°C to T130°C IP66 – IK10

Operating Temperature:

-20°C to +55°C, -40ºC to +55º (optional)

Electrical Data:

Voltage Amperage Frequency

Up to 440 V Up to 160 A 50/60 Hz

Panelboards & Motor StartersDPE Series: Distribution Panelboard – Increased Safety

Zone 1 & 2 - 21 & 22 II 2 GD

ATEX / IECIP66 - IK10

387 Visit our website at www.egsatx.com or www.appletonelec.com or contact us at +33.3.22.54.27.54. © September 2009

ATX Product Catalog

Applications:

• Protectionandcontrolofelectricalequipmentinhazardousareaswhereignitablevapors,gasesorhighlycombustible dusts are present.

• Thesecompactunitsprovideacentrallycontrolledswitchingsystemforlargequantitiesofbranchcircuitsforlighting,heattracing, small motors and similar electrical equipment.

• Forinstallationinchemicalandpetrochemicalplants,refineriesand other process industries.

Features:

• SuitableforuseinZone1&2andZone21&22.• Availableversions: - BranchCircuitBreakeravailablewithB,C

or D tripping curve. - GFIBranchCircuitBreakeravailablewithB,

C or D tripping curve. - 1,2,3,4polesand1+Nbranchcircuitbreakers• Breakersoperatorsincludedasstandardandcanbe padlockedin“OFF”position.

• Copperbusbarsasstandard.

• 3-or4-polemaincircuitbreakerorisolatorswitchcanbepadlockedinthe“ON”or“OFF”position.

• Completelywired.Easyfieldterminationtoterminalblocks.• M8Earthcrossingterminal.• 440Vacmaximum.• 60Vdc(1-pole)or125Vdc(2-pole).• Yellowlaminatedplasticlabelwithblacklettering.• Earthcontinuitybrassplate.• Hingeddoor.• Closedwithplasticdoublebarlocks(suppliedwithkey).• Suppliedwithwallsupportingframe.

Standard Material of Fixtures:

• Fiberglassreinforcedpolyesterhousing.

Options:

• -40ºC–consultfactory.• Otherratingandtrippingcurves.• 316Lstainlesssteelversion.• Othervoltagesupto480V.

DPE X X X XX XXXX X X

Main Protection:B = Main Circuit BreakerS = IsolatorSwitch

Options:S = Stainless Steel# = CustomizedPanelboard

Series:DPE = DPESeriesZone 1, 2 – 21, 22ATEX/IECCertified

Main Protection:0 = 3x40A1 = 4x40A2 = 3x63A3 = 4x63A4 = 3x100A5 = 4x100A6 = 3x125A7 = 4x125A8 = 3x160A9 = 4x160A

Panel SizeLayout:

ABCDEFGHJKLM

Branch BreakersQuantity:

03060809121824

Branch Circuit Breaker

X XXX

Intensity:01 = 1A02 = 2A03 = 3A04 = 4 A06 = 6A10 = 10A16 = 16A20 = 20A25 = 25A32 = 32A40 = 40A50 = 50A63 = 63A

Number of Poles:1 = 1-Pole2 =2-Pole3 = 3-Pole4 = 4-Pole9 = 1-Pole+N

Curve:B = Curve BC = Curve CD = Curve D

GFI:0 = without

1 = 30mA(individualbranch)2 = 300mA(individualbranch)3 = 30mA(mainbranch)4 = 300mA(mainbranch)

Catalog Number Logic:

# 6digitnumberwillbeassignedat time of order placement.

pAne

lBoA

rds

& Mo

Tor

sTAr

Ters

Panelboards & Motor StartersDPE Series: Distribution Panelboard – Increased Safety

Zone 1 & 2 - 21 & 22 II 2 GD

ATEX / IECExIP66 - IK10

388Visit our website at www.egsatx.com or www.appletonelec.com or contact us at +33.3.22.54.27.54. © September 2009

ATX Product Catalog

Branch Circuit Breakers 2-pole 16 A Layout Main Tripping (Panel Cable Volume Weight Switch Quantity Curve Size) Entries (dm3) (kg) Catalog Number

Ordering Information:Distribution Panelboard with Branch Circuit Breakers (for lighting circuits, etc.):4-polemainswitchand2-polebranchcircuitbreakerswiredonterminals.

6 C A 1xM40,6xM20 DPES3A 06216C0 4x63A 8 C B 1xM40,8xM20 DPES3B 08216C0 12 C C 1xM50,12xM20 DPES3C 12216C0

12 C D 1xM50,12xM20 DPES9D 12216C0 4x160A 18 C E 1xM50,18xM20 DPES9E 18216C0 24 C F 1xM50,24xM20 DPES9F 24216C0

Wiring Diagram:Branch Circuit Breaker Versions GFI Branch Circuit Breaker Versions

Branch Circuit Breakers 1-pole + N — 16 A/30 mA Layout Main Tripping (Panel Cable Volume Weight Switch Quantity Curve Size) Entries (dm3) (kg) Catalog Number

Distribution Panel Board with GFI Branch Cicruit Breaker (for heat tracing circuits, etc.):4-polemainswitchand1-pole+NbranchcircuitbreakerswithRCDwiredonterminals.

6 C G 1xM40,6xM20 DPES3G 06216C1 4x63A 8 C H 1xM40,8xM20 DPES3H 08216C1 12 C J 1xM50,12xM20 DPES3J 12216C1

12 C K 1xM50,12xM20 DPES9K 12216C1 4x160A 18 C L 1xM50,18xM20 DPES9L 18216C1 24 C M 1xM50,24xM20 DPES9M 24216C1

Technical Data:

INCOMING OUTGOING 4 x 63A 4 x 160 A Up to 16 A

RatedOperatingVoltage 380/415V 380/415V 220/240Vac RatedOperatingCurrent 63A 160A Upto16A

Termination(flexible/solid) Flexible 2.5to35mm2 10to70mm2 0.5to4mm2

Rigid 2.5to50mm2 10to95mm2 1.5 to 6 mm2

pAnelBoArds & MoTor sTArTers

Panelboards & Motor StartersDPE Series: Distribution Panelboard – Increased Safety

Zone 1 & 2 - 21 & 22 II 2 GD

ATEX / IECExIP66 - IK10

389 Visit our website at www.egsatx.com or www.appletonelec.com or contact us at +33.3.22.54.27.54. © September 2009

ATX Product Catalog

Dimensions (mm):

Standards: Ex Standards EN / IEC 60079-0; 60079-1; 60079-7; 61241-0; 61241-1 Product Standards EN / IEC 60947-1; 60947-2; 60947-3 EMC Standards / Other Standards EN / IEC 60529 (IP); 62262 (IK)

Compliances: Hazardous Area Gas Dust Certification Type CAe Zones 1–2 21–22 Conforming to ATEX 94/9/CE CE 0081 II 2 G CE 0081 II 2 D Symbol of Protection ATEX

Ex de IIC Ex tD A21 Symbol of Protection IEC T Rating T6 to T4 N.A. Surface Temperature N.A. T80°C to T130°C Ambient Temperature -20°C to +55°C CE Declaration of Conformity 50235 ATEX Certificate LCIE 02 ATEX 6248X IECEx Certificate IECEx LCI 04.0016X Other Certifications GOST Ingress Protection (solid and liquid) IP66

Impact Resistance (shock) IK10

Layout A*: Layout B*: Layout C*: Layout D:

Layout E: Layout F:

2 Pole Branch Circuit Breaker Versions * Main Breaker/Isolator Switch: Maximum 63A

pAne

lBoA

rds

& Mo

Tor

sTAr

Ters

Panelboards & Motor StartersDPE Series: Distribution Panelboard – Increased Safety

Zone 1 & 2 - 21 & 22 II 2 GD

ATEX / IECExIP66 - IK10

390Visit our website at www.egsatx.com or www.appletonelec.com or contact us at +33.3.22.54.27.54. © September 2009

ATX Product Catalog

Dimensions (mm) – Continued:

Layout G*: Layout H*: Layout J*: Layout K:

Layout L: Layout M:

AskyourlocalrepresentativefordetailsorvisittheAppleton websiteatwww.appletonelec.com.

Features:

• Noexternalconduitorcablesealsrequired,making installations faster, easier, and less costly.

• Featuresindividualbreakerhousingstominimizethe downtimeandcostsassociatedwithservicingcircuit breakersinhazardouslocations.

• Standardbreakersareusedandthelighterweight panelboardenclosurecanbequicklyopenedinthe fieldforeasierservicing.

• Glandplateatthebottomoftheenclosurecanbeeasily fieldpunchedforcableglandsorconduithubs.Additional glandplatesavailableforsidesandtopandmustbeorderedwiththepanelboard.

• Standardconfigurationincludesinternalactuatorsanda non-windowdoor.Factoryinstalledoptionsinclude windowdoororexternalactuators.

• 3-circuitto42-circuitpanelboardconfigurationsupto60Ampsperbranchbreaker.Largerbreakeramperagesavailable.

• Branchcircuitbreakersavailablein1,2and3-poleupto60amps.2-or3-polemaincircuitbreakersupto225ampsinaseparate enclosure.

• BreakerscanbepadlockedineithertheOnorOffposition.• Voltagerangesfrom120to600Volts.• Factorywired.Insulatedgroundandneutralbarsprovided.• Externalgroundlug.• QCbreakerterminalwirerange#14-1/0.• F-Framebreakerterminalwirerange#14-4/0.

• AccommodatesstandardQCSeriesorF-Frameseriescircuitbreakerseachindividuallycontainedinitsownhousing.

• Drain/breatherincludedasstandard.• Rated-25°Cto40°C(-40°Cwithoptionalheater).

Standard Materials:

• Enclosure:316Lstainlesssteel.• Alternateenclosure:fiberglass

reinforced polyester.• Hardware:stainlesssteel.

Compliances:

• cCSAus,cURus• ClassIDiv.2GroupB,C,D• ClassIZone1AExdeIIB+H2T6• ExdIIB+H2T6U• Type4X,IP66

North AmericanCEC/NEC Certification: PowerPlex™ Panelboards

PowerPlex™ Panelboard

pAnelBoArds & MoTor sTArTers

Panelboards & Motor StartersDPE Series: Distribution Panelboard – Increased Safety

Zone 1 & 2 - 21 & 22 II 2 GD

ATEX / IECExIP66 - IK10

3 and 4 Poles, 2 Poles GFI Branch Circuit Breaker Versions * Main Breaker/Isolator Switch: Maximum 63A