paneles led star line - maslightingmaslighting.com/paneles_star-line.pdf · paneles led star line...

6
FICHA TÉCNICA TECHNICAL DATASHEET 1 MASLIGHTING LED - Miño Iluminación S.L. Ctra. de A Coruña 107, 27003 Lugo SPAIN Tel: +34 982 263 026 - Fax: +34 982 264 026 [email protected] PANELES LED STAR LINE LED PANELS STAR LINE CARACTERÍSTICAS - FEATURES LED panel designed to reduce energy consumption, offer a uniform distri- bution of light and avoid glare and blinding effects (flicker-free panel). The best choice for workplace lighting. High quality performance thanks to its manufacturing in high quality alumi- nium, its PC prismatic diffuser that keeps a Unified Glare Rating UGR<19, and its flicker-free AGT driver. Frame and structure manufactured as single pieces, offering a clean inte- gration in ceilings of all kind thanks to its matt white finish. Suitable for Ar- mstrong ceilings, but also valid for recessed installation in plaster ceilings. Panel LED destinado a reducir el consumo de energía, ofrecer una luz uniforme, sin parpadeos y evitando deslumbramientos; la opción ideal para la iluminación de espacios de trabajo. Sus altas prestaciones vienen dadas por su construcción en aluminio de alta calidad, su difusor prismático de policarbonato que evita deslumbra- mientos (UGR<19), y su driver flicker-free AGT. Cuidada construcción, tanto su estructura como su marco son dos úni- cas piezas de aluminio, potenciando una limpia integración en todo tipo de techos gracias a su acabado blanco mate. Son aptos para techos Armstrong, pero también válidos para empotrar en techos de escayola.

Upload: others

Post on 28-Jun-2020

8 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PANELES LED STAR LINE - Maslightingmaslighting.com/Paneles_STAR-LINE.pdf · PANELES LED STAR LINE LED PANELS STAR LINE CARACTERÍSTICAS - FEATURES LED panel designed to reduce energy

FICHA TÉCNICATECHNICAL DATASHEET

1MASLIGHTING LED - Miño Iluminación S.L.Ctra. de A Coruña 107, 27003 Lugo SPAIN

Tel: +34 982 263 026 - Fax: +34 982 264 [email protected]

PANELES LED STAR LINE

LED PANELS STAR LINE

CARACTERÍSTICAS - FEATURES

LED panel designed to reduce energy consumption, offer a uniform distri-bution of light and avoid glare and blinding effects (flicker-free panel). The best choice for workplace lighting.

High quality performance thanks to its manufacturing in high quality alumi-nium, its PC prismatic diffuser that keeps a Unified Glare Rating UGR<19, and its flicker-free AGT driver.

Frame and structure manufactured as single pieces, offering a clean inte-gration in ceilings of all kind thanks to its matt white finish. Suitable for Ar-mstrong ceilings, but also valid for recessed installation in plaster ceilings.

Panel LED destinado a reducir el consumo de energía, ofrecer una luz uniforme, sin parpadeos y evitando deslumbramientos; la opción ideal para la iluminación de espacios de trabajo.

Sus altas prestaciones vienen dadas por su construcción en aluminio de alta calidad, su difusor prismático de policarbonato que evita deslumbra-mientos (UGR<19), y su driver flicker-free AGT.

Cuidada construcción, tanto su estructura como su marco son dos úni-cas piezas de aluminio, potenciando una limpia integración en todo tipo de techos gracias a su acabado blanco mate. Son aptos para techos Armstrong, pero también válidos para empotrar en techos de escayola.

Page 2: PANELES LED STAR LINE - Maslightingmaslighting.com/Paneles_STAR-LINE.pdf · PANELES LED STAR LINE LED PANELS STAR LINE CARACTERÍSTICAS - FEATURES LED panel designed to reduce energy

MASLIGHTING LED - Miño Iluminación S.L.Ctra. de A Coruña 107, 27003 Lugo SPAIN

Tel: +34 982 263 026 - Fax: +34 982 264 [email protected]

2

Ficha técnica Rev.3.4 - Technical datasheet Rev.3.4PANELES LED STAR LINE - LED PANELS STAR LINE

DATOS TÉCNICOS - TECHNICAL DATA

DRIVER - DRIVER AGT flicker-free

Voltaje de operación - Operating voltage 165-265 VAC

Factor de potencia - Power factor > 0,90

Corriente de operación - Operating current 1000mA (CC) Max 60V

Tensión de salida - Output voltage V0 = 36-62 V

Corriente de salida - Output current I0 = 900 mA

Opciones de regulación - Dimming options Opcionalmente

Protección IP - IP protection IP20

CHIP LED - LED CHIP

Modelo / Número de LED - Model / Number of chips 48 pcs 2835SMD

Vida útil estimada - Estimated lifespan 40.000 h

Eficiencia [chip] / luminaria - Efficiency [chip] / streetlight [125 Lm/W] 120±5% Lm/W (para IRC = 80)

Reproducción cromática (IRC) - Color rendering index (CRI) ≥ 80

Temperatura de color (CCT) - Color temperature 4000°K (Ref. 195013) / 5000ºK (Ref. 195020)

LUMINARIA - STREETLIGHT

Referencias - References 195013 (CCT 4000K) / 195020 (CCT 5000K)

Potencia nominal - Rated power 40W

Potencia total - Total power 40,2W ±5%

Flujo luminoso total - Total luminous flux 4.800 Lm ±5%

Ángulo de apertura - Beam angle 160°

Rdto. Lumínico, LOR (%) - Luminous performance 100%

ULORinst [FHSinst] - ULORinst [FHSinst] 0%

Rango de temperatura - Temperature range -20º ≈ +65ºC

Humedad relativa - Operating humidity 20% ≈ 95%

Clase eléctrica - Class Class I

Índice Deslumbramiento Unificado - Unified Glare Rating UGR<19

Grado de protección (IP) - IP protection IP20

Grado de protección (IK) - IK protection IK07

Materiales - Materials Luminaria - StreetlightFabricación en aluminio de alta calidad, acabado blanco mate; difusor prismático de policarbonato.Made of high quality aluminium, matt white finished; prismatic diffuser made of PC.

Montaje - Installation Empotrado - Recessed

Dimensiones generales (mm) - Overall dimensions (mm) L595 x W595 x H30 mm

Medidas de corte (mm) - Cutting dimensions (mm) L570 x W570 mm

Peso neto (kg) - Net weight (kg) 2,8 kg

Dimensiones embalaje (mm) - Packaging size (mm) L625 x W655 x H30 mm

Garantía - Warranty 3 años - 3 years

W595mm

L595mm

H30mm

Page 3: PANELES LED STAR LINE - Maslightingmaslighting.com/Paneles_STAR-LINE.pdf · PANELES LED STAR LINE LED PANELS STAR LINE CARACTERÍSTICAS - FEATURES LED panel designed to reduce energy

MASLIGHTING LED - Miño Iluminación S.L.Ctra. de A Coruña 107, 27003 Lugo SPAIN

Tel: +34 982 263 026 - Fax: +34 982 264 [email protected]

3

Ficha técnica Rev.3.4 - Technical datasheet Rev.3.4PANELES LED STAR LINE - LED PANELS STAR LINE

DATOS FOTOMÉTRICOS (INCLINACIÓN 0°) - PHOTOMETRIC DATA

DISTRIBUCIÓN DE INTENSIDAD (PLANOS C)

(C PLANE) DISTRIBUTION DIAGRAM

MÁXIMA INTENSIDAD

MAXIMUM INTENSITY

DIAGRAMA CÓNICO

CONIC DIAGRAM

UNIDAD: cd

C0/180 C30/210 C60/240 C90/270

Grado de apertura promedio (50%): 163.8ºAverage beam angle (50%): 163.8º

Page 4: PANELES LED STAR LINE - Maslightingmaslighting.com/Paneles_STAR-LINE.pdf · PANELES LED STAR LINE LED PANELS STAR LINE CARACTERÍSTICAS - FEATURES LED panel designed to reduce energy

MASLIGHTING LED - Miño Iluminación S.L.Ctra. de A Coruña 107, 27003 Lugo SPAIN

Tel: +34 982 263 026 - Fax: +34 982 264 [email protected]

4

Ficha técnica Rev.3.4 - Technical datasheet Rev.3.4PANELES LED STAR LINE - LED PANELS STAR LINE

DATOS FOTOMÉTRICOS (INCLINACIÓN 0°) - PHOTOMETRIC DATA

Page 5: PANELES LED STAR LINE - Maslightingmaslighting.com/Paneles_STAR-LINE.pdf · PANELES LED STAR LINE LED PANELS STAR LINE CARACTERÍSTICAS - FEATURES LED panel designed to reduce energy

MASLIGHTING LED - Miño Iluminación S.L.Ctra. de A Coruña 107, 27003 Lugo SPAIN

Tel: +34 982 263 026 - Fax: +34 982 264 [email protected]

5

Ficha técnica Rev.3.4 - Technical datasheet Rev.3.4PANELES LED STAR LINE - LED PANELS STAR LINE

DRIVERS REGULABLES COMPATIBLES - SUITABLE DIMMABLE DRIVERS

Fuentes de corriente constante digitales y configurables mediante interruptores

Digital constant current drivers, configurable through switches

Regulación: 0..10V, DALI, Pulsador, PWM

Protecciones SCP, OCP, OVP, OTP

Eficiencia típica del 90%

Dimming: 0..10V, DALI, PUSH, PWM

SCP, OCP, OVP, OTP protections

Typical efficiency 90%

Certificaciones CE, TUV, ENEC

Encendido instantáneo (t < 0,5 seg)

Bajo consumo en stand-by (0,5W)

CE, TUV, ENEC Certifications

Immediate start (t < 0,5 sec)

Low consumption on stand-by mode (0,5W)

188886 191343

Tensión de alimentación - Input voltage 180 – 265VAC (380VAC, t<3seg)

Potencia - Power 38 - 69W 38 - 69W

Corriente de salida - Output current 800 - 2000 mA 800 - 2000 mA

Tensión de salida - Output voltage 3 - 42V 3 - 42V

Regulación - Dimming 0..10V DALI-PUSH

Dimensiones - Size (LxWxH) L123 x W79 x H31 mm L123 x W79 x H31 mm

Tª funcionamiento - Operating temperature -20º ~ +50°C -20º ~ +50°C

123

112

6

4

4

6

68 79

31

NORMATIVAS Y CERTIFICADOS IEC/EN - IEC/EN TANDARDS & CERTIFICATES

2014/30/EU - EMC - Directiva Compatibilidad Electromagnética - Electromagnetic Compatibility Directive

EN 55015:2007 + A2:2009

Límites y métodos de medida de las características relativas a la perturbación radioeléctrica de los equipos de iluminación y similares.

Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment.

EN 61547:2011

Equipos para iluminación para uso general. Requisitos relativos a la inmunidad CEM.

Equipment for general lighting purposes - EMC immunity requirements

EN 61000-3-2:2006 /A2:2010

Compatibilidad electromagnética (CEM). Parte 3-2: Límites. Límites para las emisiones de corriente armónica (equipos con corriente de entrada <= 16 A por fase)

Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current <= 16 A per phase)

EN 61000-3-3:2009

Compatibilidad electromagnética (CEM). Parte 3-3: Límites. Limitación de las variaciones de tensión, fluctuaciones de tensión y flicker en las redes públicas de suministro de baja tensión para equipos con corriente asignada <= 16 A por fase y no sujetos a una conexión condicional.

Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current <= 16 A per phase and not subject to conditional connection

EN 61347-1:2016

Dispositivos de control de lámpara. Parte 1: Requisitos generales y requisitos de seguridad.

Lamp controlgear - Part 1: General and safety requirements

EN 62493:2011

Evaluación de los equipos de alumbrado en relación a la exposición humana a los campos electromagnéticos.

Assessment of lighting equipment related to human exposure to electromagnetic fields

Page 6: PANELES LED STAR LINE - Maslightingmaslighting.com/Paneles_STAR-LINE.pdf · PANELES LED STAR LINE LED PANELS STAR LINE CARACTERÍSTICAS - FEATURES LED panel designed to reduce energy

MASLIGHTING LED - Miño Iluminación S.L.Ctra. de A Coruña 107, 27003 Lugo SPAIN

Tel: +34 982 263 026 - Fax: +34 982 264 [email protected]

Due to the technical processes of reproduction, colors may be approximate, not exact. All data included on this datasheet is correct, except for typographical error.

For the improvement of our products Maslighting LED, we re-serve the right to cancel or modify any of the models, sizes, references and technical specifications contained in this datas-heet without prior notice.

Debido a los procesos técnicos de reproducción, los colores pueden ser aproximados, no exactos. Los datos incluidos en esta ficha técnica son correctos, salvo error tipográfico.

Para la mejora de nuestros productos Maslighting LED se reser-va el derecho de anular o modificar cualquiera de los modelos, tamaños, referencias y especificaciones técnicas contenidas en esta ficha técnica sin previo aviso.

6

Ficha técnica Rev.3.4 - Technical datasheet Rev.3.4PANELES LED STAR LINE - LED PANELS STAR LINE

NORMATIVAS Y CERTIFICADOS IEC/EN - IEC/EN TANDARDS & CERTIFICATES

2009/125/EC - ErP - Productos Relacionados con la Energía - Energy related Products

2011/65/EU - RoHS - Restricción de Sustancias Peligrosas - Restrictions of Hazarous Substances

2014/35/EU - LVD - Directiva Baja Tensión - Low Voltage Directive

EN 60598-1:2009

Luminarias. Parte 1: Requisitos generales y ensayos.

Luminaires - Part 1: General requirements and tests.

EN 60598-2-1: 2012

Luminarias. Parte 2-1: Requisitos particulares. Luminarias fijas de uso general.

Luminaires - Part 2-1: Particular requirements – Fixed general purpouse luminaires.

EN 62471:2008

Seguridad fotobiológica de lámparas y de los aparatos que utilizan lámparas.

Photobiological safety of lamps and lamp system