The PANTHER is a solid state electronic condensate removal system designed to fi t neatly inside even the smallest high wall split air conditioners or trunking.The PANTHER’s electronic reservoir sensing unit eliminates all worries about positioning. This versatile little unit is so easy-going that you’re spoilt for choice.
2 3 4 5 6 71 9 10 11 12 13 148 16 17 18 19 2015
1
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
30 40 5010 6020
0
0
00
Vertical lift
(m)
(ft)
Flow
rate
(l/h)
(US
gal/h
))
0m Horiz50m Horiz100m Horiz
Capacity
• Electronic Energy Control System (EECS) with alarm circuit • Soft start with “EECS”• No fl oat to stick• Thermal protection• Tiny reservoir – sensing unit• Low profi le for ease of mounting• Amazingly quiet• Fits all wall-mount splits• CE marked
Power supply: 110/230 V, 50/60 Hz Auto sensing
Power consumption: 17 W max., 0.25 when idle
Alarm relay: 5 A, 30 VDC, 250 VAC Break on fault
Capacity: 12 litres/hour max. (3.6 US gal/h)
Discharge head: >20 m (65 ft) vertical,
>100 m (328 ft) horizontal
1 m max. (3.28 ft) suction
Ambient temp: 0° C - 40° C (32 F to 104 F)
Material: Flame retardant ABS - UL94 5 VA
Discharge tube: 6 mm (1/4“) ID
Supply cable lenght: 1.5 meters
Pump-sensor-tube: Lenght 1.5 m, dia. 3.3 mm (1/8“)
Dimensions pump: 135 x 46 x 32 mm (5.3“ x 1.8“ x 1.26“)
Dimensions sensor: 45 x 36 mm dia. (1.8“ x 1.4“ dia.)
PANTHER
The Electronic Energy Control System (EECS) reins
in energy consumption by operating at the minimum
possible power for the amount of detected condensate.
So quiet you really won‘t know it‘s there unless you installed it yourself!
Subject to change without notice
Description Part No.PAN.6000.0 3001911
The Electronic Energy Control System (EECS) reins
in energy consumption by operating at the minimum
possible power for the amount of detected condensate.
The JAGUAR condensate pump is easy to fi t and easy to maintain – the pump is made for installers. Speedy fi tting is assured with the JAGUAR. Completely automatic operation is enhanced by the intelli-gent Electronic Energy Control System (EECS) circuitry to guarantee quiet starting and stopping, as well as power control to regulate the amount of energy required to remove the condensate.
Capacity
• Electronic Energy Control System (EECS) with alarm circuit • Soft start with “EECS”• Powerful and compact• No fl oat to stick• Thermal protection• Amazingly quiet• High water alarm and cut-out switch• Vertical or horizontal mounting• Fits all high-wall-mount air conditioner• CE marked
System (EECS) circuitry to guarantee quiet starting and stopping, as well as power control to regulate the amount of energy required to remove the condensate.
• High water alarm and cut-out switch• Vertical or horizontal mounting• Fits all high-wall-mount air conditioner• CE marked
Power supply: 110/230 V, 50/60 Hz Auto sensing
Power consumption: 17 W max., 0.25 when idle
Alarm relay: 5 A, 30 VDC, 250 VAC Break on fault
Capacity: 12 litres/hour max. (3.17 US gal/h)
Discharge head: >20 m (65 ft) vertical,
>100 m (328 ft) horizontal
1 m max. (3.28 ft) suction
Ambient temp: 0° C - 40° C (32 F to 104 F)
Material: Flame retardant ABS - UL94 5 VA
Discharge tube: 6 mm (1/4“) ID
Dimensions: 175 x 46 x 40 mm (6.9“ x 1.8“ x 1.6“)
JAGUARSo quiet you really won‘t know it‘s there unless you installed it yourself!
The compact and powerful one piece easy to install pump
2 3 4 5 6 71 9 10 11 12 13 148 16 17 18 19 2015
1
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
30 40 5010 6020
0
0
00
Vertical lift
(m)
(ft)
Flow
rate
(l/h)
(US
gal/h
))
0m Horiz50m Horiz100m Horiz
Subject to change without notice
Description Part No.PAN.6000.0 3001911
Description Part No.JAG.6000.0 3001918
The COUGAR drain pan pump is a submersible condensate removal pump designed to automatically remove condensate water from refrigerated cases, dehumidifi ers, fan coils and air conditioning systems. The pump is intended to be installed within a collection tray inside the equipment.The water level is measured by an electronic Energy Control System (EECS) this controls the operation of the pump via the fully-encapsulated circuitry.
• Electronic Energy Control System (EECS) with alarm circuit • Soft start with “EECS”• All electrical components safely encapsulated against moisture ingress• Submersible• Amazingly quiet• Powerful and compact• Filter and non-return valves built in• No mechanical fl oats to stick• CE marked
Capacity
The COUGAR drain pan pump is a submersible condensate removal pump designed to automatically remove condensate water from refrigerated cases, dehumidifi ers, fan
• Electronic Energy Control System (EECS) with alarm circuit • Soft start with “EECS”• All electrical components safely
Power supply: 110/230 V, 50/60 Hz Auto sensing
Power consumption: 17 W max., 0.25 when idle
Alarm relay: 5 A, 30 VDC, 250 VAC Break on fault
Capacity: 12 litres/hour max. (3.17 US gal/h)
Discharge head: >20 m (65 ft) vertical,
>100 m (328 ft) horizontal
1 m max. (3.28 ft) suction
Ambient temp: 0° C - 40° C (32 F to 104 F)
Material: Flame retardant ABS - UL94 5 VA
Discharge tube: 6 mm (1/4“) ID
Dimensions: 160 x 43 x 34 mm (6.3“ x 1.7“ x 1.3“)
COUGAR
The compact and powerful one piece easy to install pump
The smart alternative to a tank pump or a condensate pan heater
2 3 4 5 6 71 9 10 11 12 13 148 16 17 18 19 2015
1
1
2
3
4
5
6
7
8
9
10
11
12
1
2
3
30 40 5010 6020
0
0
00
Vertical lift
(m)
(ft)
Flow
rate
(l/h)
(US
gal/h
))
0m Horiz50m Horiz100m Horiz
Subject to change without notice
Description Part No.JAG.6000.0 3001918