paris - celco r290... · paris integral freezer and ... the latest technologies and which nearly...

Download Paris - Celco R290... · Paris Integral freezer and ... the latest technologies and which nearly requires no manual effort. The hygiene of the freezer and also of the ... PARIS 145

If you can't read please download the document

Upload: tranhuong

Post on 10-Feb-2018

228 views

Category:

Documents


3 download

TRANSCRIPT

  • Paris Integral freezer and chiller cabinets. Ready to plug in.

    The nexT level To boosT your sales.

    www.ahtusa.net

    ECO-FRIENDLY

    r290

  • 1 Preset is fixed at 39 F possibility to change to another temperature by a service technician. For product quality reasons, semiautomatic defrosting is not possible in Meat / Ground

    meat operating mode.

    Chiller and freezer uniT wiTh maximum ProduCT disPlay.

    Temperature ranges

    Chilling +37 F to +59 F1

    Freezing 0 F to 9 F

    Meat and ground meat refrigeration +32 F to +36 F2

    made possible by static cooling and circulated air technology!Please contact us for additional information.

    Highly flexible As a stand alone unit

    As a line up

    As an island

    maximum use of floor space with an end cabinet

    End Cabinet

    Integrated Controller

    The PARIS model. This cabinet has been designed with shaped lids and its front edge has been lowered to enable customers to look directly into the cabinet. This means that you can provide maximum product visibility and experience increased sales opportunities. The PARIS model comes with an internal light that will attract customers who will be able to see the products clearly displayed within the cabinet something that should result in an increase in impulse purchases. This exceptional innovation can be either used as a stand alone cabinet or banked together into an island. When used within an island, the PARIS model includes an optional end cabinet that will not only successfully optimize space but also create an aesthetically pleasing end to the island itself. The PARIS range can also be installed below shelving.

    Key benefits High energy savings compared

    with conventional open units

    Experience approximately additional 25% energy savings through an electronic speed-controlled compressor (VS)

    Environmentally friendly with natural refrigerant propane (R290)

    New synthetic interior casing for better hygiene and easy cleaning

    Intelligent fan motor for more energy efficiency saves approximately 0,5 kWh daily

    100 % CFC- and PFC-free

    Plug-in System (120V) no aisle drains required

    Low investment and operation costs

    maintenance-free refrigeration technology

    multi Temp (U) offers 3 temperature ranges that can be changed easily through the controller

    Brilliant LED lighting system which enhances product display, drives sales and reduces maintenance

    Constant interior temperature and high power reserves ensure high merchandise quality

  • Skirting

    Impact protection bumpers

    Curved lids for optimum product display

    Air channel

    Accessories Product labelling and price tags

    Impact protection bumpers in different colors available

    Air channel and side panel for island setup

    Skirting reduces water, dirt and dust from getting under the cabinet

    Superstructure

    Optional paint to any RAL color (for larger order quantities)

    ECO-FRIENDLY

    r290

  • The perfect solution built in semi-automatic defrost! (AD)

    Regular defrosting...

    ...with goods kept at a constant temperature

    At AHT Cooling Systems, we managed to successfully put this principle into practice by developing a semi-automatic defrost which works independently, on basis of the latest technologies and which nearly requires no manual effort. The hygiene of the freezer and also of the products stored within fully complies with the highest standards. As the defrosting of our static freezers is based on a sophistically timed sequence of heating periods in the innertank.

    Frost build-up due to ambient humidity is successfully melted away at regular inter-vals and this avoids any excessive frost build-up. Furthermore, during the thawing process, the temperature of the goods will always remain below 5 F, hence fully complying with legal requirements. The use of a special divider system will prevent any adverse effects on the temperature of your goods and melted ice water collects in a duct that surrounds the inner case and is evaporated away outside of the storage area.

    auTomaTiC defrosT PermanenTly on duTy!

    Synthetic interior case for higher product quality, easier cleaning and improved defrost water drain.

    Frost build-up is thawed during auto-defrost

    new synTheTiC inTerior Casing

  • Paris 145 185 210 Technical Data () AD VS IQ LED (U) AD VS IQ LED () AD VS IQ LED (U)* AD VS IQ LED () AD VS IQ LED (U)* AD VS IQ LED

    Gross content cu.ft. 21.5 21.5 28.2 28.2 32.9 32.9

    Net content cu.ft. 15.0 14.2/9.2/13.5 20.2 19.5 / 12.8 / 18.7 23.5 22.9 / 15.0 / 22

    Total display area (TDA) sq.ft. 8.8 8.8 11 11 13.4 13.4

    Ambient temperature range F 61 to 77 61 to 77 61 to 77 61 to 77 61 to 77 61 to 77

    Inner temperature range F 0 to 9 37 to 59 / 32 to 36 / 0 to 9 0 to 9 37 to 59 / 32 to 36 / 0 to 9 0 to 9 37 to 59 / 32 to 36 / 0 to 9

    Sound pressure in 1 m distance dB(A) 43 43 43.8 43.8 44 44

    Electrical Data

    Nominal voltage / frequency V / Hz 110-120 / 60 110-120 / 60 110-120 / 60 110-120 / 60 110-120 / 60 110-120 / 60

    Nominal power consumption cabinet W 320 320 400 400 400 400

    Power consumption illumination LED W 28 28 29 29 39 39

    Nominal current A 3.2 3.2 3.6 3.6 3.6 3.6

    Fuse protection A 15 15 15 15 15 15

    Energy consumption (at 77 F)**kWh / 24 h 4.5 1.7 / 2.6 / 4.5 5.1 1.8 / 2.8 / 5.1 5.4 2.3 / 3 / 5.4

    BTU / 24 h 15358 5802 / 8873 / 15358 17405 6143 / 9556 / 17405 18429 7849 / 10238 / 18429

    Length of power supply cord inch 68.9 68.9 68.9 68.9 68.9 68.9

    Refrigeration Data

    Refrigerant type R290 R290 R290 R290 R290 R290

    Refrigerant charge oz 2.8 2.8 3.2 3.2 3.5 3.5

    Max. operating pressure bar 30 30 30 30 30 30

    Dimensions

    Length outside / inside inch 57.4 / 52.3 57.4 / 52.3 73.0 / 67.8 73.0 / 67.8 82.8 / 77.7 82.8 / 77.7

    Depth outside/inside inch 33.6 / 28.5 33.6 / 28.5 33.6 / 28.5 33.6 / 28.5 33.6 / 28.5 33.6 / 28.5

    Front access height/height outside inch 30.3 / 32.8 30.3 / 32.8 30.3 / 32.8 30.3 / 32.8 30.3 / 32.8 30.3 / 32.8

    Stacking height*** inch 21.7 22.4 / 15 / 21.7 21.7 22.4 / 15.0 / 21.7 21.7 22.4 / 15.0 / 21.7

    Weight

    Net weight (excl. packaging, incl. internal accessories for cooling process) lb 209 229 265 284 300 320

    Gross weight (incl. packaging and internal accessories for cooling process) lb 225 243 287 306 324 344

    * Universal cabinet: The cabinet covers all three temperature ranges of refrigeration 37 F to 59 F / beef and ground beef refrigeration 32 F to 36 F / freezing 0 F to 9 F.

    ** In practical use, the power consumption is approx. 10-20 % lower, which is due to usually lower ambient temperature and small loads.

    *** The load line corresponds to the height of the baskets with ground beef refrigeration.

    PARIS 185

    NEmA Plug Type: L5-15 P

  • Subj

    ect

    to t

    echn

    ical

    mod

    ifica

    tions

    and

    typ

    ogra

    phic

    al e

    rror

    s. V

    ersi

    on:

    04/2

    015

    Paris 145 185 210 Technical Data () AD VS IQ LED (U) AD VS IQ LED () AD VS IQ LED (U)* AD VS IQ LED () AD VS IQ LED (U)* AD VS IQ LED

    Gross content cu.ft. 21.5 21.5 28.2 28.2 32.9 32.9

    Net content cu.ft. 15.0 14.2/9.2/13.5 20.2 19.5 / 12.8 / 18.7 23.5 22.9 / 15.0 / 22

    Total display area (TDA) sq.ft. 8.8 8.8 11 11 13.4 13.4

    Ambient temperature range F 61 to 77 61 to 77 61 to 77 61 to 77 61 to 77 61 to 77

    Inner temperature range F 0 to 9 37 to 59 / 32 to 36 / 0 to 9 0 to 9 37 to 59 / 32 to 36 / 0 to 9 0 to 9 37 to 59 / 32 to 36 / 0 to 9

    Sound pressure in 1 m distance dB(A) 43 43 43.8 43.8 44 44

    Electrical Data

    Nominal voltage / frequency V / Hz 110-120 / 60 110-120 / 60 110-120 / 60 110-120 / 60 110-120 / 60 110-120 / 60

    Nominal power consumption cabinet W 320 320 400 400 400 400

    Power consumption illumination LED W 28 28 29 29 39 39

    Nominal current A 3.2 3.2 3.6 3.6 3.6 3.6

    Fuse protection A 15 15 15 15 15 15

    Energy consumption (at 77 F)**kWh / 24 h 4.5 1.7 / 2.6 / 4.5 5.1 1.8 / 2.8 / 5.1 5.4 2.3 / 3 / 5.4

    BTU / 24 h 15358 5802 / 8873 / 15358 17405 6143 / 9556 / 17405 18429 7849 / 10238 / 18429

    Length of power supply cord inch 68.9 68.9 68.9 68.9 68.9 68.9

    Refrigeration Data

    Refrigerant type R290 R290 R290 R290 R290 R290

    Refrigerant charge oz 2.8 2.8 3.2 3.2 3.5 3.5

    Max. operating pressure bar 30 30 30 30 30 30

    Dimensions

    Length outside / inside inch 57.4 / 52.3 57.4 / 52.3 73.0 / 67.8 73.0 / 67.8 82.8 / 77.7 82.8 / 77.7

    Depth outside/inside inch 33.6 / 28.5 33.6 / 28.5 33.6 / 28.5 33.6 / 28.5 33.6 / 28.5 33.6 / 28.5

    Front access height/height outside inch 30.3 / 32.8 30.3 / 32.8 30.3 / 32.8 30.3 / 32.8 30.3 / 32.8 30.3 / 32.8

    Stacking height*** inch 21.7 22.4 / 15 / 21.7 21.7 22.4 / 15.0 / 21.7 21.7 22.4 / 15.0 / 21.7

    Weight

    Net weight (excl. packaging, incl. internal accessories for cooling process) lb 209 229 265 284 300 320

    Gross weight (incl. packaging and internal accessories for cooling process) lb 225 243 287 306 324 344

    AHT Cooling Systems USA Inc.3235 Industry Drive North Charleston SC 29418 Tel. 800-905-4768 (toll free) or 843-767-6855 Email [email protected] www.ahtusa.net

    OHSAS 18001 SA 8000

    ISO 9001 ISO 14001

    Certification and listing according to the regulations of the California Energy Commission as well as to the regulations of Natural Resources Canada have been obtained for several of the above units. Please contact AHT for further information.

    approved according to ANSI/NSF 7

    approved according to ANSI/UL 471

    PARIS 145 210

    Case standard with extension feet providing an additional 1 of under case clearance and to total height.

    For version AD/U the inner dimensions are reduced due to the necessary use of wire grids along the inside walls.