part – iii price bid · cb 2000a 40ka 3s with str and clamp connectors as per technical spec set....

33
Sign & seal of Bidder 1 GUJARAT ENERGY TRANSMISSION CORPORATION LIMITED SARDAR PATEL VIDYUT BHAVAN RACE COURSE, VADODARA - 390 007 TENDER FOR Supply, Erection, Testing and commissioning of 220 kV & 66kVequipments, materials on EPC basis excluding civil works at 220KV Lunawada s/s TENDER NO: GETCO/EPC/220KV Lunawada/24 PART – III Price Bid

Upload: others

Post on 19-Mar-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 1

GUJARAT ENERGY TRANSMISSION CORPORATION LIMITED SARDAR PATEL VIDYUT BHAVAN

RACE COURSE, VADODARA - 390 007

TENDER FOR

Supply, Erection, Testing and commissioning of 220 kV & 66kVequipments, materials on EPC basis excluding civil works at 220KV Lunawada s/s

TENDER NO: GETCO/EPC/220KV Lunawada/24

PART – III

Price Bid

Page 2: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 2

This page has been kept intentionally Blank.

Page 3: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 3

ANNEXURE – A to Bidding schedule for supply prices Name 0f Substation :---------------------

Sr. No.

Description

Unit

Qty.

Rate unit Ex Works

Unit F.O.R. in

Rs.

(4 + 5+6)

Excise duty.

% as well as amount

Sale Tax

% as well as amount

CST = ON (4+9)

VAT = ON (4+9)

Unit end Cost Price in Rs.

(7+9+11)

Total Amount

in Rs

Frei-ght charges

Insurance

charges

10 11

Rate in %

1 2 3 3A 4

5

6

7 8

Rate in % of Ex-Works

price

9

Unit E.D.

Amount Rs. CST VAT

Total

amount Rs.

12 13

F.O.R COST IN RS.

(3 X 7 )

14 END

COST IN RS.

(3 X 12 )

Material Description & Qty. shall be as per supply price schedules

I/ We agree to supply the articles noted above at the rates herein tendered by me/ us subject to the condition

of tender and supply of the Tender inquiry, which I / We have carefully read and thoroughly understood.

I/ We hereby agree to keep this offer open for 180 days after the date

of the opening of technical bid of tenders and shall be bound by communication of acceptance dispatched within the prescribed time.

Bidder's seal Date : ___________________________*

Page 4: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 4

ANNEXURE – B -Bidding schedule for erection & commissioning prices

Name of Substation:---------------------- Amount in Rs.

• Material Description & Qty. shall be as per Erection price schedule.

I/ We agree to execute the articles noted above at the rates herein tendered by me/ us subject to the

condition of tender and execute of the Tender inquiry, which I / We have carefully read and thoroughly

understood.

I/ We hereby agree to keep this offer open for 180 days after the date of the opening of technical bid of

tenders and shall be bound by communication of acceptance dispatched within the prescribed time.

Bidder's Name: ____________________________

Signature: ____________________________

Name: ____________________________

Designation: ____________________________

Bidder's

Seal

Date : ___________________________

SR.

NO.

Descriptio

n

Unit

Qty. Particulars

Erection/

Commissi

oning rate

per unit

Service

tax

Any

other

Tax

Unit rate

of

erection

& comm.

charges +

service

tax +any

other tax

Total erection

&

commissioning

charges on end

cost basis (Qty.

x Unit rate

TOTAL

Page 5: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 5

TENDER NO: GETCO/EPC/220KV Lunawada/24

Supply, Erection, Testing and commissioning of 220 kV & 66kVequipments, materials on EPC basis excluding civil works at 220KV Lunawada s/s

SUMMARY

Sr.No Name of Substation Supply Erection TOTAL

1 220KV Lunawada S/S

TOTAL

In words Rs

Page 6: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 6

BOQ for 220kV LUNAWADA SUB-STATION

Sr. No.

Particulars of Item Unit Supply

Qty. Erection

Qty.

A Supply and Erection of 220kV Equipments as per respective Technical Specifications and relevant special conditions .

1

Surge Arrester 198kV, 10kA, Cl-3 with str and clamp connectors as per Technical spec No. 12 12

2

PT 220kV/√3-/110V/√3-3C with str and clamp connectors as per Technical spec No. 6 6

3

BPI 8kN with str and clamp connectors as per Technical spec

No. 159 159

4

HBPI 8kN with str and clamp connectors as per Technical spec

No. 24 24

5

HDB Isolator with one ES 1600A 40kA 3s with str and clamp connectors as per Technical spec

Set. 4 4

6

HDB Isolator without ES 1600A 40kA 3s with str and clamp connectors as per Technical spec

Set. 2 2

7

Tandem DB Isolator 1600A 40kA 3s with str and clamp connectors as per Technical spec

Set. 17 17

8

CT conventional 1200-600-300/1, 4C with str and clamp connectors as per Technical spec

No. 15 15

9

CT- Optical type universal Ration muticore(Requirement of Ratioo 1200-600-300/1 and core 4) with structure, Cable and clamp connector

No. 3 3

10

CB 2000A 40kA 3s with str and clamp connectors as per Technical spec

Set. 6 6

B

Supply and Erection of 220kV Switchyard materials as per respective Technical Specifications and relevant special conditions suitable for Two Main Bus with Twin ACSR Moose conductor and Transfer Bus with Twin ACSR Moose conductor scheme & relevant Flyover Bus with Twin ACSR Moose conductor.

1 Gantry structures GI as per BOM, Steel & A/B part

MT 107.3

2

Gantry structures GI as per BOM, Bolt nut part

MT 6.7

114

3

VHF Tower Mast Structure GI with stub, template complete as per BOM, Steel & A/B part

MT 1.65

4

VHF Tower Mast structures GI with stub, template complete as per BOM, Bolt nut part

MT 0.05

1.7

Page 7: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 7

5

Stringing of bus with Twin Moose ACSR conductor for all the three phases with required insulators, hardwares & accessories, spacers provided at every 3.0 mtr. interval etc. complete as per relevant standards and approved drawings with Jumpers for continuous Bus Arrangement (It includes cost of Conductor,insulators, hardwares & accessories, spacers etc. all items required for satisfactory functioning. Any variation in quantities shall be absorbed by contractor). – Break up As per Annexure-6

a Main Bus with 36Mtr span including bus jumpers

No. of Span 10 10

b Transfrer Bus with 36Mtr span including bus jumpers

No. of Span 5 5

c Trasformer flyover bus with 74Mtr span

No. of Bay 2 2

d Bus Coupler Flyover Bus with 74Mtr. Span

No. of Bay 1 1

6

Stringing of Earth Wire with 7/3.15 GS wire with required hardwares & accessories etc. complete as per standards and approved drawings for span of 74 meters.(It includes cost of Earthwire,hardwares & accessories, etc. all items required for satisfactory functioning. Any variation in quantities shall be absorbed by contractor). Break up As per Annexure-6

Span 8 8

7

Droppers (including required suspension string with hardware & accessories if any) & Jumpers (including Equipment to Equipment) with Twin Moose ACSR conductor as per standards and approved drawings with provision of required spacers (Suitable for 350mm spacing) at every 3.0 mtr. interval. (It includes cost of Conductor, insulators, hardwares & accessories, Fire Wedge connectors, spacers etc.all items required for satisfactory functioning. Any variation in quantities shall be absorbed by contractor). Break up As per Annexure-6

a 220/66KV Transformer Bay No. of

bay 2 2

b 220KV Line Bay No. of

bay 2 2

c

220KV Bus Coupler Bay No. of bay 1 1

d

220KV Transfer Bus Coupler Bay No. of bay 1 1

8

Droppers (including required suspension string with hardware & accessories if any) & Jumpers with Single Moose ACSR conductor as per standards and approved drawings (It includes cost of Concuctor,insulators, hardwares & accessories, Fire Wedge Connectors, etc. all items required for satisfactory functioning. Any variation in quantities shall be absorbed by contractor) Break up As per Annexure-6

a 220KV Line Bay - LA & CVT No. of

bay 2 2

b

220/66KV Transformer Bay - LA No. of bay 2 2

c 220KV PT Bay No. of

bay 2 2

Page 8: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 8

C

Supply and Erection of 66kV Equipments as per respective Technical Specifications and relevant special conditions suitable.

1 Power Transformer 66/11kV 5MVA with oil and accessories, connector suitable for single Moose ACSR.

No. 1 1

2 Surge Arrester 60kV, 10KA, Class 3 with structure and clamp connectors suitable for single Moose ACSR.

No. 27 27

3 PT 66kV/v3-/110V/v3-2C with structure and clamp connectors suitable for single Moose ACSR. No. 6 6

4 BPI 4kN with structure and clamp connectors suitable for single Moose ACSR.

No. 56 56 5 BPI 4kN with structure and clamp connectors suitable for Twin

Zebra ACSR. No. 28 28

6 HBPI 4kN with structure and clamp connectors suitable for Twin Zebra ACSR. No. 6 6

7 HDB Isolator with one ES 630A 25kA 3s with structure and clamp connectors suitable for Single Moose ACSR.

Set. 6 6

8 HDB Isolator without ES 630A 25kA 3s with structure and clamp connectors suitable for Single Moose ACSR.

Set. 15 15 9 HDB Isolator without ES 630A 25kA 3s with structure and clamp

connectors suitable for Single Moose ACSR(3nos./set) & Twin Zebra ACSR(3nos./set).

Set. 2 2

10 HDB Isolator without ES 1250A 25kA 3s with structure and clamp connectors suitable for Twin Zebra ACSR.

Set. 6 6

11 CT 600-300/1 3C, 31.5KA 3S with structure and clamp connectors suitable for Single Moose ACSR. No. 18 18

12 CT 1200-600/1 3C 31.5KA 3S with structure and clamp connectors suitable for Twin Zebra ACSR. No. 9 9

13 CT 100-50/1 3C 31.5KA 3S with structure and clamp connectors suitable for Single Moose ACSR. No. 3 3

14 CB 1600A 25kA 3S with structure and clamp connectors suitable for Single Moose ACSR. Set. 7 7

15 CB 1600A 25kA 3S with structure and clamp connectors suitable for Twin Zebra ACSR. Set. 3 3

D

Supply and Erection of 66kV Switch Yard Material as per respective Technical Specifications and relevant special conditions suitable for Two Main Bus with Twin ACSR Zebra conductor scheme & relevant Flyover Bus with Twin ACSR Zebra conductor.

1 Gantry structures GI as per BOM , Steel & A/B part

MT 55.56

2 Gantry structures GI as per BOM , Bolt nut part MT 6.66

62.22

Page 9: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 9

3 Stringing of bus for all the three phases with Twin Zebra ACSR conductor, insulators hardwares, spacers (suitable for 350mm spacing) at interval of 4.0 mtr complete as per relevant standards and approved drawings. The scope includes the cost of Conductor, insulators, hardwares, accessories, spacers etc. all items required for satisfactory operation. Any variation in quantities shall be absorbed by erection contractor). Break up As per Annexure-6

a Main Bus with 34.63 Mtr. Span including bus jumpers Span 6 6

b Main Bus with 35.04 Mtr. Span including bus jumpers Span 2 2

c Line flyover bus with 23.8 Mtr. Span No. of bay 10 10

d 66/11KV Trf. flyover bus with 23.8 Mtr. Span No. of bay 1 1

e Transformer flyover bus with 50.7 Mtr. Span No. of bay 2 2

f Transformer flyover bus with 13.8 Mtr. Span No. of bay 2 2

4 Stringing of Earth Wire with 7/3.15 GS wire with required hardwares & accessories etc. complete as per standards and approved drawings for the shown span. (It includes cost of Earthwire,hardwares & accessories etc. all items for satisfactory functioning. Any variation in quantities should be absorbed by erection contractor). Break up As per Annexure-6

a For Main Bus with 34.63 Mtr. Span Span 10 10 b For Main Bus with 35.04 Mtr. Span

Span 4 4

c Line flyover bus with 23.8 Mtr. Span No. of bay 10 10

d 66/11KV Trf. flyover bus with 23.8 Mtr. Span No. of bay 1 1

e Transformer flyover bus with 50.7 Mtr. Span No. of bay 2 2

f Transformer flyover bus with 13.8 Mtr. Span No. of bay 2 2

5 Droppers (including required suspension string with hardware & accessories if any) & Jumpers with Single Moose ACSR conductor as per standards and approved drawings. (It includes cost of Conductor,insulators, hardwares & accessories etc. all items required for satisfactory functioning. Any variation in quantities shall be absorbed by erection contractor). Break up As per Annexure-6

a 220/66KV Transformer Bay - LA bay 2 2

b 66KV PT Bay bay 2 2

c 66KV Line Bay - LA bay 6 6

d 66/11KV Transformer Bay bay 1 1

Page 10: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 10

6 Droppers and Jumpering (equipment to equipment) with Twin Zebra ACSR conductor as per standards and approved drawings with provision of spacers suitable for 350mm spacing at 4.0 mtr interval. The scope includes the cost of Conductor,accessories, spacers, fire wedge connectors etc.all items required for satisfactory operation. Any variation in quantities shall be absorbed by erection contractor. Break up As per Annexure-6

a 220/66KV Transformer Bay (66KV side) bay 2 2

b 66KV Bus Coupler Bay bay 1 1

E

Supply and Erection of General purpose equipments and materials as per respective technical specifications and relevant special conditions.

1

Suitable arrangement of 11KV connection from 5MVA 66/11kV transformer to distribution tr (11/0.415kV) with required 22kV CT, its junction box, support structure insulated conductor and DP structure with DO fuse, 22kV BPIs arrangement for proteciton of dist transformer and mounting arrangement of Dist box suitable to dist transformer. Package LS LS

2

AC unit 3 Ton Split for Control room (5 star rating and reputed make) No. 3 3

3 AC unit 1.5 Ton Split for Office No. 2 2

4 AC unit 3 Ton Split for PLCC Room No. 2 2

5 Distribution Transformer 500 kVA with suitable Dist. Box and its fixing -mounting arragement. Set 1 1

6

Providing major spares as per Ann A attached herewith

Set 1 0

7

Providing instruments as per Ann B attached herewith

Set 1 0

8

Providing tools and tackles etc. as per Ann C attached herewith

Set 1 0

9

Providing RO Water Filter System, Water Cooler, Furniture, Etc. as per Ann D attached herewith Set 1 0

10

Supply and Erection of Fire stand with 4 buckets including concreting as per our drawing & Instruction of E. I. C.

Set 1 1

11

Providing of rubber Matting (size 3'x3'x20mm) in control room

No. 60 0

12

Supply including installation of ISI marked fire extinguishers of various types required for 220 KV sub station.

1) Dry chemical powder type of 10 Kg. capacity.

No. 2 0

2) Dry chemical powder type of 25 Kg. capacity.

No. 1 0

3) Dry chemical powder type of 50 Kg. capacity.

No. 1 0

4) Carbon dioxide ( CO2) gas type of capacity 6.5 Kg. capacity

No. 2 0

5) Carbon dioxide (CO2) gas type of capacity 22.5 Kg. capacity

No. 1 0

6) Mechanical Foam type of capacity 9 LT.

No. 2 0

Page 11: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 11

7) Mechanical Foam type of capacity 50 LT.

No. 1 0

F

Supply and installation of materials for Illumination system in all respect as per respective specifications and special conditions (Sucessful bidder has to submit the complete design and BOQ for approval)

1

Providing & Fixing of Energy Efficient T5 type Indoor decorative luminaries in all the rooms of control room building complete (ref. Ann-4 Item (A)) as per technical spec Cl No. 2.10.4.8 (EEI type ) as per design with respect to required lux level and relevant tender drgs. with required industrial grade point wiring as per technical spec. Scope also includes providing and fixing of 15/5 A plug, Portable Emergency Light, Bell, Fan, Ex- Fan, DC Point, with requisite MCBs and DC 100W lamp , DC Plug etc all items as per Ann-4 Item (A) in following rooms

i Control Room Package LS LS

ii PLCC Room Package LS LS

iii Office Package LS LS

2

Providing & Fixing of Energy Efficient T5 Industrial type Indoor luminaries in all the rooms, passages of control room building complete (ref. Ann-4 item (A)) as per technical spec Cl No. 2.10.4.8 (EEI type) as per design with respect to required lux level and relevant tender drgs. with required industrial grade point wiring as per technical spec. Scope also includes providing and fixing of 15/5 A plug, Portable Emergency Light, Bell, Fan, Ex- Fan, DC Point, with requisite MCBs and DC 100W lamp,DC Plug etc all items as per Ann-4 Item (A) in following rooms, passages etc.

i Battery Room Package LS LS

ii LV Room Package LS LS

iii Store Room Package LS LS

iv Ramp Slope Package LS LS

v Veranda Package LS LS

vi Toilet Gents Package LS LS

vii WC Package LS LS

viii Toilet Ladies Package LS LS

ix Passage (Corridor) Package LS LS

x Water Room Package LS LS

Page 12: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 12

3

Providing and fixing of flood light luminaries as per design for 220kV switch yard area with Philips/CGL/Bajaj/GE/Oshram make HPSV 150/250/400W lamp with energy efficient type choke (HF) with control gear box & ancillaries and suitable for mounting on structure at appropriate height ( as per design) as per specifications TS illuminations cl. no 2.10.4.8 with necessary GI fabrication & GI bolt nuts to fix control gear box at the structure with complete internal and external wiring to J. box ,Dist panel/section feeder pillar etc with supply of required 3 c x 2.5 mm2 copper armoured cable (as per spec). The scope includes supply and erection of all the materials required for satisfactory functioning of above work.

Package LS LS

4

Providing and fixing of flood light luminaries as per design for 66kV switch yard area with Philips/CGL/Bajaj/GE/Oshram make HPSV 150/250W lamp with energy efficient type choke (HF) with control gear box & ancillaries and suitable for mounting on structure at appropriate height ( as per design) as per specifications TS illuminations cl. no 2.10.4.8 with necessary GI fabrication & GI bolt nuts to fix control gear box at the structure with complete internal and external wiring to J. box ,Dist panel/section feeder pillar etc with supply of required 3 c x 2.5 mm2 copper armoured cable (as per spec ) .The scope includes supply and erection of all the materials required for satisfactory functioning of above work.

Package LS LS

5

Providing and installation of post top lantern for main gate and road from main gate to swichyard via control room as per design with Philips/CGL/Bajaj/GE/Oshram make and energy efficient type suitable wattage lamp with control gear box & ancillaries suitable for mounting on Gate pillars and 4.5 mtr poles with necessary GI fabrication & GI bolt nuts to fix control gear box with complete internal and external wiring to J.box,Dist panel/section feeder pillar, fixing terminal etc. with supply of required 3 c x 2.5 mm2 copper armoured cable as per spec .This also includes the supply and erection of required 4.5 mtr poles and its foundation work as per spec and earthing with main mesh. The scope includes supply and erection of all the materials required for satisfactory functioning of above work.

Package LS LS

Page 13: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 13

6

Providing and fixing of street light luminaries for reamaing area (like road, peripheral area etc.) of switch yard complete as per design with Philips/CGL/Bajaj/GE/Oshram make and energy efficient type 70 W (or suitable wattage )lamp with control gear box & ancillaries suitable for mounting on 7.0 mtr swaged poles as per spec.TS illuminations cl. no 2.10.4.8 (EEO2) at appropriate height with necessary GI fabrication & GI bolt nuts to fix control gear box with complete internal and external wiring to J. box ,dist panel/section feeder pillar, fixing terminal etc with supply of required 3 c x 2.5 mm2 copper armoured cable (as per spec). This also includes the supply and erection of 7.0 mtr swaged pole and foundation work as per spec. and panting with two coats of primer and two priming of zinc chromate as well as earthing with main mesh. The scope includes supply and erection of all the materials required for satisfactory functioning of above work.

Package LS LS

7

Supply and Erection of main lighting Panel ACP-1 as per Specifications. Set comprises minimum 2 nos.of such panels qty may be more if required as per design.Scope also includes the providing and erection of 25x6 GI strip for earthing with main mesh

Set 1 1

8

Supply and Erection of main lighting Panel ACP-2 as per Specifications Set comprises minimum 4 nos.of such panels qty may be more if required as per design.Scope also includes the providing and erection of 25x6 GI strip for earthing with main mesh

Set 1 1

9

Supply and Erection of main lighting Panel ACP-3 as per Specifications Set comprises minimum 4 nos.of such panels qty may be more if required as per design.Scope also includes the providing and erection of 25x6 GI strip for earthing with main mesh

Set 1 1

10

Supply and Erection of main lighting Panel ACP-4 as per Specifications Set comprises minimum 2 nos.of such panels qty may be more if required as per design.Scope also includes the providing and erection of 25x6 GI strip for earthing with main mesh

Set 1 1

11

Supply and Erection of main Yard light Dist. Board as per designed capacity ratings.Scope also includes the providing and erection of 50x6 GI strip for earthing with main mesh

Nos 2 2

12

Providing of concreting in 1:2:4 mix including muffing for erection of pole & Dist boxes panels including excavation of HR/SR as per approved drawing. Package LS LS

13

Providing & fixing of ' B ' Class ISI marked GI pipe of 25 mm inner diameter for cable looping, road crossing with necessary elbow / band to J. Box etc. Package LS LS

Page 14: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 14

14

Providing and fixing of GI clamp (25mm wide GI strip with 6 mm GI nut bolts) on structure at approx. 1/2 Mtr. Interval for clamping of cable . Clamp should be fix in such a way that cable can be easily mount inside it & sustain standing on structure. This also includes required other materials ,accessories required for complete functioning of Illumination system of whole project (switch yard and all buildings, structures) those are not covered in this schedule for Illumination. Please refer the drawing "General Schematic for Illumination" in the TS Illumination.

Package LS LS

Note: The qunatities of the ACP's mentioned in the schedule of requirement are based on std. requirement, which shall be finalised during detail engineering. The bidder has to assess the qty. of ACP's at the time of quoting the bid. The qty of ACP's finalised during detail engineering is binding to the bidder & no any extra payment shall be made. In all the case the decision of GETCO will be final.

G

Supply and installation of materials for Earthing system in all respect as per respective specifications and special conditions ( Sucessful bidder has to submit the complete design and BOQ for approval).

1

Supply and Installation of earthing strips/round bars as shown below including digging of 600 mm depth and 450 mm wide trench fixing on structure as per std equipment earthing phylosophy incuding fixing arrangement with two bolt arrangement, jointing, welding etc. complete.

a) 75 x 10 mm GI strip. RMt. 8800 8800

b) 50 x 6 mm GI strip. RMt. 7940 7940

c) 40 mm dia steel rod RMt. 15260 15260

d) 40mm dia 3mtr long steel rod Nos. 127 127

e) 7/3.15 Earth wire for earthing of Towers with peak RMt. 1000 1000

2

Providing and installing Check pit as per drawing and instruction of Engineer In charge with provision of earth chamber.

Nos. 6 6

3

Installation of treated pipe electrode providing 100 mm inner diameter CI pipe of 13 mm thickness and 3000 mm length as per GETCO drg No P011. Work includes fabrication and fixing of GI strips for earthing connection. Nos. 54 54

4

Providing BB masonary inspection chamber (man hole) incl.light type CI cover as per GETCO drawing no P011

Nos. 54 54

Note: Extra earth should be removed away from the site s/s premises or refilling earthing pits if required. All required materials for this job such as CI pipe, CI cover with frame, salt, cement, sand, charcoal/bentonite, gravel, bricks etc. to be supplied by the contractor.

H

Supply and Erection of Ladder Type Cable Trays and Accesories as per respective Technical Specifications and relevant special conditions.

Width of tray

400mm Rmtr. 1132 1132

Page 15: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 15

300mm Rmtr. 475 475

Length: Standard length of tray is 2500mm, Height is 75mm, Thickness is 2mm (min.)

I PLCC ITEMS

1 220kV ,4400PF CVT (having two windings with VA burden

50 & 50 and having accuracy of 3P & 0.2 class for protection

& metering core respectively) with clamp/connectors &

supporting structure. The interconnection from HF terminal of

CVT to PLCC coupling device shall be made using 16 Sq.mm

PVC insulated stranded (non flexible strands) copper cable.

No. 4 4

2 220kV, 0.5mH, 1250Amp Wave Trap with Blocking Band of,

Band-(I)-100-160 & Band-(II) 150-500KHz and R min = 570

Ohm and single point suspension arrangement with three tie

rod assembly including insulator string assembly,

clamp/connectors and require acce

No. 4 4

3 Modular coupling device MCD-80, Make: ABB (Set

comprising of 1 No. of A9BS & 1 No. of A9BT) for Phase to

Phase coupling arrangement for PLCC signal connectivity.

Set 2 2

4 40 Watt single channel fully programmable carrier terminal of

Make: ABB &Type: ETL-41,

No. 2 2

5 Protection coupler Make: ABB & Type: NSD-50 with 2

coded & 2 uncoded command arrangement & perfectly match

with above carrier terminal description of which given at Sr.

No. 4 above.

No. 2 2

6 50 Volt, 350AH capacity, storage Low Maintenance , High

performance Lead acid Battery set with accessories & FRP

stand

set (25 cells/set)

1 1

7 Float & boost charger suitable for 50Volt, 350AH capacity

battery with float 0/p volt : 50 to 58 volt, 40 Amp, Boost 0/p :

50 to 72V, 35 Amp with Variac & Servo Motor mechanism

for Auto Operation for DC O/P Voltage Adjustment of Float

Charger as per technical specification.

No. 1 1

8 DCDB with 10 Nos. of Feeders (6 Amp each) for DC supply

to PLCC panels & Exchange as per technical Specification.

No. 1 1

9 laying of 75 Ohm, unbalanced armoured co-axial cable for

PLCC signal connectivity and providing UHF gland on both

the ends of each main cable length to be laid for PLCC

carrier room to bay gentry and loop cable for Ph to Ph

coupling arrangement.

KM 1.1 1.1

10 PLCC Exchange No. 1 1

Page 16: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 16

11 DAS Meters network wiring complete up to RS 485 to RS

232 Convertor of DAS PC using

Job 1 1

a) 3 core communication cable (as per specification given

hereunder)

Mtr. 100

b) RS 485 to RS 232 Converter (as per specification given hereunder)

No. 1

Protection Items

J

Supply and Erection of Protection equipments and materials as per respective technical specifications and relevant special conditions and suitable for Two Main and Transfer Bus system on 220kV side

1 Control & Protection panels for 220KV Bays ( Control Voltage - 220V DC ) as per tech specifications with following break up

1) Control & Protection panel for line Set 2 2

2) Control & Protection panel for Transformer with Differential

Set 2 2

3) Control & Protection panel for TBC Set 1 1

4) Control & Protection panel for BC Set 1 1

5) Busbar Protection Panel - Having Central Unit compatibility for 24 bays and 6 Nos of Paripheral Units (CU & PU shall be mounted in respective bay control and protection panels as shown in GA)

Set 1 1

2

GPS based Time Syncronising Unit (IEC 61850 compatible)

Set 1 1

K

Supply and Erection of Protection equipments and materials as per respective technical specifications and relevant special conditions and suitable for Two Main Bus system on 66kV side

1 Protection Panel for 66kV bays ( Control Voltage - 220V DC ) as per tech specifications with following break up.

1) Control & Protection Panel for two 66kV lines Set 3 3

2) Control & Protection Panel for Transformer With Differential Relay (For 66/11kV TR) & Buscoupler Set

1 1

3) Control & Protection Panel for Transformer W/O Differential Relay (For 220/66kV TR) & 66KV Line Set

2 2

4) Under Frequency Panel Set 1 1

L AC-DC Auxiliaries

1

Battery set - 220 V, 250Ah (2 V, 110 cells) Plante´ type Lead Acid Battery Set with FRP stand of adequate size

No. 2 2

2 Battery Charger - 220 V (Float - 30A / Boost - 50A) - (SCADA compatible) No. 2 2

3 DCDB-220 V with 35 Feeder No. 0 0

4 DCDB-220 V with 20 Feeder No. 4 4

5 LTPB - (SCADA compatible) No. 2 2

M

Supply and installation of materials/item for Power Cable and control Cable wiring as per approved wiring schedule.

Page 17: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 17

1

Supply and Laying of 1.1 kV PVC armoured copper/Aluminum control / LT power cable in trench including binding/clamping of cable with GI wire as per requirement including supply and fixing of identification tags on both ends and at distance of every 100mtr. (Note :- Aluminum cables of size 185 mm

2 & above shall be XLPE

type)

1) 2c x 2.5 mm

2, copper control cable

Mtr. 2800 2800

2) 2c x 4 mm

2 , copper control cable

Mtr. 1150 1150

3) 4cx2.5 mm

2, copper control cable

Mtr. 2550 2550

4) 4c x 4 mm2 , copper control cable

Mtr. 5400 5400

5) 7c x 2.5 mm

2, copper control cable

Mtr. 1450 1450

6) 12c x 2.5 mm2, copper control cable

Mtr. 2200 2200

7) 12c x 4 mm2, copper control cable

Mtr. 2700 2700

8) 19c x 2.5 mm2 , copper control cable

Mtr. 4600 4600

9) 27c x 2.5 mm

2 , copper control cable

Mtr. 950 950

10A) 1 x 50 mm

2 , copper cable

Mtr. 2050 2050

10B) 4C x 10 mm

2 , copper control cable

Mtr. 150 150

11) 4 x 10 mm

2 , Al. armoured LT cable

Mtr. 400 400

12) 3.5 x 25 mm

2 , Al. armoured LT cable

Mtr. 1300 1300

13) 1C x 150 mm2 , Al. armoured LT cable

Mtr. 2500 2500

Termination of the control cable at panel / MK box/equipment including PVC binding dressing/shaping drilling of holes in panels for glands nuts for following size. The work also includes Looping in panel and MK box with using crimping type of lugs of suitable size with ferruling with proper size of copper cable wire. The loops should be bunched with using button tape and proper shaping etc.

1) cables from 2 core to 7 core of 2.5 & 4.0 Sq.mm size

No. 625 625

2

2) cables above 7 core No. 600 600

Laying of 1.1kv PVC/XLPE armored Al. LT power cable in ground by digging trench of suitable width and 450 mm depth with providing and fixing of brick and sand layer covering the cable in any type of soil and Laying of 1.1kv PVC armored copper control cable in heavy duty PVC pipe of suitable size buried in ground by digging trench of suitable width and 450 mm depth in any type of soil including supply and fixing of Pipe and identification tags at distance of every 100 Mtrs for following size

3

1) Control Cables upto 7 core Mtr. 450 450

Page 18: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 18

2) Control Cables above 7 core and all LT cables Mtr.

1150 1150

Providing and fixing of 50mm dia 'B' class GI pipes with necessary size of band and couplings for control cable protection of CT, PT/CVT etc. equipments including fixing with structures as per instruction of Engineer-in-charge.

1) 220 kV Switch Yard Mtr. 125 125

4

3) 66 kV switch yard Mtr. 125 125

Providing and fixing of 100mm dia 'B' class GI pipes with necessary size of band and couplings for control cable protection of CB, Isolator etc.equipments including fixing with structures as per instruction of Engineer-in-charge.

1) 220 kV Switch Yard

Mtr. 225 225

4a

2) 66 kV switch yard Mtr. 75 75

5 Providing and fixing bay MK as per tech spec No. 8 8

6 Providing and fixing Yard LT ACDB as per tech spec -with 20 OG feeders No. 1 1

7 Providing and fixing Yard LT ACDB as per tech spec -with 12 OG feeders

No. 2 2

8

Providing and fixing of all weather proof, cold rolled sheet steel junction box for CVT & PT, CT terminations with 30 Nos. of disconnecting type, 'Elmex' make CATDM 4 or equivalent type connectors and required no of fuses, links etc.as per instruction of Engineer-in-charge.

No. 14 14

N Supply and Erection of SCADA equipments and materials as

per respective technical specifications and relevant special conditions and suitable for Two Main and Transfer Bus system on 220kV side and Two Main Bus on 66KV side

1 Bay Control Unit / RTU for Substation Auxiliaries # Nos 1 1 2 Bay Control Unit for PLCC ** Nos 1 1 3 HMI Server computer with required softwares Nos 2 2

4 DR workstation PC No. 1 1

5 Gateway for remote control with software No 1 1

6 Gateway for RTU Data with software No 1 1

7 SCADA software (For local end only) No 1 1 8 Ethernet Fiber Switches* Nos 7 7 9 Line Interface unit - 2 Cable entry, 12 ports Nos 8 8

10 Line Interface unit - 8 Cable entry, 32 ports Nos 1 1

11 Dismentaling of existing earth wire of the existing line portion Km 0 0

12 Erection of OPGW on the whole line with all required accessories Km

0

13 OPGW Terminal equipments (FOTE) with required hardware and software for remote connectivity Set 0 0

13A Armoured Fibre Optic approach cable with HDPE duct for connecting OPGW to FOTE MTR. 0 0

14 Laser Jet colour Printer Nos 1 1

15 Laser Jet Printer Nos 1 1

Page 19: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 19

16 3 KVA UPS with battery (12V, 26AH X 30 Nos, SMF Battery) Nos 1 1

17 3 KVA UPS without battery Nos 1 1 18 Modem for RTU Data Nos 2 2

19 Armoured Fibre Optic Cable with HDPE duct MTR. 1150 1150

20 Yard Kiosk for 220KV Switchyard

Internal Dimensions - 4000 (L) X 3500 (W) X 3300 (H) mm Nos 3 3

21 Yard Kiosk for 66KV Switchyard

Internal Dimensions - 5000 (L) X 3500 (W) X 3300 (H) mm Nos 2 2

22 Panel for mounting SCADA equipments Nos 1 1

23 Panel for mounting PLCC BCU Nos 1 1

24 Panel for mounting Station Auxiliaries BCU/RTU Nos 1 1

25 False Flooring in SCADA Room of Control Building as per following ANNEXURE - 1

Sq Mtr 75 75

O Spares for SCADA and Protection

1 Bay Control Unit Nos 1 1

2 Line Interface unit - 8 Cable entry, 32 ports Nos 1 1

3 Ethernet fiber switch Nos 1 1

4 Busbar Protection Peripheral Unit Nos 1 1

NOTE:

Supply & Erection of 220/66KV Transformer is not in the scope of awardee, but awardee will erect the itmes other than the scope of transformer manufacturer and witness during the erection and testing of the same and provide all the result in as built drawings/documents.

1) Any material/equipment accessories which are not listed in BOQ or scope of supply but required to

complete the job shall be included and shown in technical bid.

2)*Ethernet switches shall have as many spare ports as utilized ports.

3) ** PLCC BCU shall have sufficient I/Os as per given list.

4) # BCU for station Auxiliary shall have sufficient I/Os as per list or otherwise suitable RTU shall be provided.

Page 20: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 20

Annexure- 6

Engineering BOQ Breakup for 220kV Lunawada Sub-Station

Sr.No. Particulars of Item Unit Supply Qty.

Erection Qty.

B

Supply and erection of 220kV Swithyard materials (as per respective Technical Specifications and relevant special conditions) suitable for Two Main Bus & Transfer Bus with Twin ACSR Moose conductor & relevant Flyover Bus with Twin ACSR Moose conductor.

Stringing of bus with Twin Moose ACSR conductor for all the three phases with required insulators, hardwares & accessories, spacers provided at every 3.0 mtr. interval etc. complete as per relevant standards and approved drawings with Jumpers for continuous Bus Arrangement (It includes cost of Conductor,insulators, hardwares & accessories, spacers etc. all items required for satisfactory functioning. Any variation in quantities shall be absorbed by contractor)-Qty. per span of 3phase

5a

Main Bus with 36Mtr span including bus jumpers

No. of Span 10 10

ACSR Moose Conductor per Span Rmtr. 216

Insulators-120KN AF Per Span No. 192 192

Double Tension H/W & Acc.with Turn Buckle -Twin Moose ACSR Per Span

No. 3 3

Double Tension H/W & Acc.w/o Turn Buckle -Twin Moose ACSR Per Span

No. 3 3

Spacers suitable for Twin Moose ACSR (350mm Spacing) in Main Bus Per Span

No. 27 27

Spacers suitable for Twin Moose ACSR (350mm Spacing) in Main Bus Jumpers (Total)

No.

72 72

5b

Transfer Bus with 36Mtr span including bus jumpers

No. of Span 5 5

ACSR Moose Conductor per Span Rmtr. 216

Insulators-120KN AF Per Span No. 192 192

Double Tension H/W & Acc.with Turn Buckle -Twin Moose ACSR Per Span

No. 3 3

Double Tension H/W & Acc.w/o Turn Buckle -Twin Moose ACSR Per Span

No. 3 3

Spacers suitable for Twin Moose ACSR (350mm Spacing) Per Span

No. 27 27

Spacers suitable for Twin Moose ACSR (350mm Spacing) in Main Bus Jumpers (Total)

No.

36 36

5c Transformer flyover bus with 74 Mtr span

No. of Bay 2 2

Page 21: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 21

ACSR Moose Conductor per Span Rmtr. 444

Insulators-120KN AF Per Span No. 192 192

Double Tension H/W & Acc.with Turn Buckle -Twin Moose ACSR Per Span

No. 3 3

Double Tension H/W & Acc.w/o Turn Buckle -Twin Moose ACSR Per Span

No. 3 3

Spacers suitable for Twin Moose ACSR (350mm Spacing) Per Span

No. 66 66

5d Bus Coupler Flyover Bus with 74 Mtr. Span

No. of Bay 1 1

ACSR Moose Conductor per Span Rmtr. 444

Insulators-120KN AF Per Span No. 192 192

Double Tension H/W & Acc.with Turn Buckle -Twin Moose ACSR Per Span

No. 3 3

Double Tension H/W & Acc.w/o Turn Buckle -Twin Moose ACSR Per Span

No. 3 3

Spacers suitable for Twin Moose ACSR cond. (350mm Spacing) Per Span

No. 66 66

6

Stringing of Earth Wire with 7/3.15 GS wire with required hardwares & accessories etc. complete as per standards and approved drawings for span of 74 meters.(It includes cost of Earthwire,hardwares & accessories etc. all items required for satisfactory functioning. Any variation in quantities shall be absorbed by contractor)

Span 8 8

Earthwire per Span Rmtr. 74

Earthwire Access.- Suitable for 7/3.15 GS per span No.

2 2

7

Droppers (including required suspension string with hardware & accessories if any) & Jumpers (including Equipment to Equipment) with Twin Moose ACSR conductor as per standards and approved drawings with provision of required spacers (Suitable for 350mm spacing) at every 3.0 mtr. interval (It includes cost of Conductor,insulators, hardwares & accessories, Fire Wedge connectors, spacers etc. all items required for satisfactory functioning. Any variation in quantities shall be absorbed by contractor)-Qty. per bay of 3phase

a 220/66KV Transformer Bay (200KV Side) No. of bay 2 2

ACSR Moose Conductor per Bay Rmtr. 841

Insulators-120KN AF Per Bay No. 90 90

Single Suspension H/W & Acc.-Twin Moose ACSR Per Bay

No. 6 6

Spacers suitable for Twin Moose ACSR (350mm Spacing) Per Bay

No. 89 89

Fire Wedge Connectors suitable for Moose ACSR to Moose ACSR Per bay

No. 18 18

Page 22: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 22

b 220KV Line Bay No. of bay 2 2

ACSR Moose Conductor per Bay Rmtr. 612

Insulators-120KN AF Per Bay No. 45 45

Single Suspension H/W & Acc.-Twin Moose ACSR Per Bay

No. 3 3

Spacers suitable for Twin Moose ACSR (350mm Spacing) Per Bay

No. 65 65

Fire Wedge Connectors suitable for Moose ACSR to Moose ACSR Per bay

No. 18 18

Fire Wedge Connectors suitable for Zebra ACSR to Moose ACSR Per bay

No. 6 6

c 220KV Bus Coupler Bay No. of bay 1 1

ACSR Moose Conductor per Bay Rmtr. 510

Insulators-120KN AF Per Bay No. 45 45

Single Suspension H/W & Acc.-Twin Moose ACSR Per Bay

No. 3 3

Spacers suitable for Twin Moose ACSR (350mm Spacing) Per Bay

No. 52 52

Fire Wedge Connectors suitable for Moose ACSR to Moose ACSR Per bay

No. 18 18

d 220KV Transfer Bus Coupler Bay No. of bay 1 1

ACSR Moose Conductor per Bay Rmtr. 478

Spacers suitable for Twin Moose ACSR (350mm Spacing) Per Bay

No. 55 55

Fire Wedge Connectors suitable for Moose ACSR to Moose ACSR Per bay

No. 18 18

8

Droppers (including required suspension string with hardware & accessories, if any) & Jumpers with Single Moose ACSR conductor as per standards and approved drawings (It includes cost of Conductor, insulators, hardwares & accessories, Fire Wedge Connectors, etc.all items required for satisfactory functioning. Any variation in quantities shall be absorbed by contractor)-Qty. per bay of 3phase

a 220kV Line Bay-LA & CVT No. of

Bays 2 2

ACSR Moose Conductor per Bay Rmtr. 84

Fire Wedge Connectors suitable for Zebra ACSR to Moose ACSR Per bay

No. 5 5

b 220/66KV Transformer Bay (200KV Side) - LA No. of

Bays 2 2

ACSR Moose Conductor per Bay Rmtr. 7.5

Fire Wedge Connectors suitable for Moose ACSR to Moose ACSR Per bay

No. 3 3

c 220KV PT Bay No. of

Bays 2 2

ACSR Moose Conductor per Bay Rmtr. 27.5

Insulators-120KN AF Per Bay No. 45 45

Page 23: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 23

Single Suspension H/W & Acc.-Single Moose ACSR Per Bay

No. 3 3

D

Supply and Erection of 66kV Switch Yard Material as per respective Technical Specifications and relevant special conditions suitable for Single Bus with Twin Zebra ACSR Conductor

3 Stringing of bus for all the three phases with Twin Zebra ACSR conductor, insulators hardwares, spacers (suitable for 350mm spacing) at interval of 4.0 mtr complete as per relevant standards and approved drawings. The scope includes the cost of Conductor, insulators, hardwares, accessories, spacers etc. all items required for satisfactory operation. Any variation in quantities shall be absorbed by erection contractor)-Qty. per span/bay of 3phase

a Main Bus with 34.630 Mtr. Span including bus jumpers Span 6 6

ACSR Zebra Conductor per Span Rmtr. 207.78

Insulators-90KN AF Per Span No. 72 72

Double Tension H/W & Acc.with Turn Buckle -Twin Zebra ACSR Per Span

No. 3 3

Double Tension H/W & Acc.w/o Turn Buckle -Twin Zebra ACSR Per Span

No. 3 3

Spacers suitable for Twin Zebra ACSR (350mm Spacing) Per Span

No. 21 21

Spacers suitable for Twin Zebra ACSR (350mm Spacing) in Main Bus jumpers (Total)

No.

12 12

b Main Bus with 35.04 Mtr. Span including bus

jumpers Span 2 2

ACSR Zebra Conductor per Span Rmtr. 210.24 Insulators-90KN AF Per Span No. 72 72

Double Tension H/W & Acc.with Turn Buckle -Twin Zebra ACSR Per Span

No. 3 3

Double Tension H/W & Acc.w/o Turn Buckle -Twin Zebra ACSR Per Span

No. 3 3

Spacers suitable for Twin Zebra ACSR (350mm Spacing) Per Span

No. 21 21

Spacers suitable for Twin Zebra ACSR (350mm Spacing) in Main Bus jumpers (Total)

No.

6 6

c Line flyover bus with 23.8 Mtr. Span Span 6 6

ACSR Zebra Conductor per Span Rmtr. 142.8 Insulators-90KN AF Per Span No. 72 72 Double Tension H/W & Acc.with Turn Buckle -

Twin Zebra ACSR Per Span No.

3 3

Double Tension H/W & Acc.w/o Turn Buckle -Twin Zebra ACSR Per Span

No. 3 3

Spacers suitable for Twin Zebra ACSR (350mm Spacing) Per Span

No. 12 12

Page 24: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 24

d 66/11KV Trf. flyover bus with 23.8 Mtr. Span

Span 1 1

ACSR Zebra Conductor per Span Rmtr. 142.8

Insulators-90KN AF Per Span No. 72 72

Double Tension H/W & Acc.with Turn Buckle -Twin Zebra ACSR Per Span

No. 3 3

Double Tension H/W & Acc.w/o Turn Buckle -Twin Zebra ACSR Per Span

No. 3 3

Spacers suitable for Twin Zebra ACSR (350mm Spacing) Per Span

No. 12 12

e 220/66KV Transformer flyover bus with 50.7

Mtr. Span (66KV side) No. of bay 2 2

ACSR Zebra Conductor per Bay Rmtr. 304.2

Insulators-90KN AF Per Span No. 72 72

Double Tension H/W & Acc.with Turn Buckle -Twin Zebra ACSR Per Span

No. 3 3

Double Tension H/W & Acc.w/o Turn Buckle -Twin Zebra ACSR Per Span

No. 3 3

Spacers suitable for Twin Zebra ACSR (350mm Spacing) Per Span

No. 33 33

f 220/66KV Transformer flyover bus with 13.8

Mtr. Span (66KV side) No. of bay 2 2

ACSR Zebra Conductor per Bay Rmtr. 82.8 Insulators-90KN AF Per Span No. 72 72

Double Tension H/W & Acc.w/o Turn Buckle -Twin Zebra ACSR Per Span

No. 3 3

Spacers suitable for Twin Zebra ACSR (350mm Spacing) Per Span

No. 33 33

Spacers suitable for Twin Zebra ACSR (350mm Spacing) Per Span

No. 6 6

4 Stringing of Earth Wire with 7/3.15 GS wire

with required hardwares & accessories (including spike reqd, if any) etc. complete as per standards and approved drawings for the shown span. (It includes cost of Earthwire,hardwares & accessories etc. all items for satisfactory functioning. Any variation in quantities should be absorbed by erection contractor).

a For Main Bus with 34.630 Mtr. Span Span 10 10 Earthwire per Span Rmtr. 34.63 Earthwire Access.- Suitable for 7/3.15 GS per

span No. 2 2

b For Main Bus with 35.04 Mtr. Span Span 4 4 Earthwire per Span Rmtr. 35.04 Earthwire Access.- Suitable for 7/3.15 GS per

span No. 2 2

c Line bay 23.8Mtr. Span No. of bay 6 6 Earthwire per Bay Rmtr. 23.8

Page 25: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 25

Earthwire Access.- Suitable for 7/3.15 GS per span No.

2 2 d 66/11KV Trf. flyover bus with 23.8 Mtr. Span

No. of bay 1 1

Earthwire per Span Rmtr. 23.8 Earthwire Access.- Suitable for 7/3.15 GS per

span No. 2 2

e 220/66KV Transformer flyover bus with 50.7

Mtr. Span (66KV side) No. of bay 2 2

Earthwire per Span Rmtr. 50.7 Earthwire Access.- Suitable for 7/3.15 GS per

span No. 2 2

f 220/66KV Transformer flyover bus with 13.8 Mtr. Span (66KV side) No. of bay 2 2

Earthwire per Span Rmtr. 13.8

Earthwire Access.- Suitable for 7/3.15 GS per span No.

2 2

5 Droppers (including required suspension string with hardware & accessories if any) & Jumpers with Single Moose ACSR conductor as per standards and approved drawings. (It includes cost of Conductor,insulators, hardwares & accessories etc. all items required for satisfactory functioning. Any variation in quantities shall be absorbed by erection contractor).-Qty. per bay of 3phase

a 220/66KV Transformer Bay (66KV Side) - LA

No. of bay 2 2

ACSR Moose Conductor per Span Rmtr. 19

Fire Wedge Connectors suitable for Zebra ACSR to Moose ACSR Per bay

No. 3 3

b 66KV PT Bay No. of bay 2 2

ACSR Moose Conductor per Span Rmtr. 18

c 66KV Line Bay No. of bay 6 6

ACSR Moose Conductor per Span Rmtr. 166.67 Insulators-90KN AF Per Bay No. 30 30

Single Suspension H/W & Acc. Per Bay No. 6 6 Fire Wedge Connectors suitable for Zebra

ACSR to Moose ACSR Per bay No.

9 9

Fire Wedge Connectors suitable for Moose ACSR to Moose ACSR Per bay

No. 3 3

Fire Wedge Connectors suitable for Panther ACSR to Moose ACSR Per bay

No. 6 6

Fire Wedge Connectors suitable for Dog ACSR to Moose ACSR Per bay (only for one line out of six lines)

No.

6 6

d 66/11KV Transformer Bay No. of bay 1 1

ACSR Moose Conductor per Span Rmtr. 122 Insulators-90KN AF Per Bay No. 15 15

Page 26: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 26

Single Suspension H/W & Acc. Per Bay No. 3 3

Fire Wedge Connectors suitable for Zebra ACSR to Moose ACSR Per bay

No. 9 9

Fire Wedge Connectors suitable for Moose ACSR to Moose ACSR Per bay

No. 3 3

6 Droppers (including required suspension string

with hardware & accessories if any) and Jumpering (equipment to equipment) with Twin Zebra ACSR conductor as per standards and approved drawings with provision of spacers suitable for 350mm spacing at 4.0 mtr interval. The scope includes the cost of Conductor, accessories ,spacers, fire wedge connectors etc.all items required for satisfactory operation. Any variation in quantities shall be absorbed by erection contractor -Qty. per bay of 3phase

a 220/66KV Transformer Bay (66KV Side) No. of bay 2 2

ACSR Moose Conductor per Span Rmtr. 333 Insulators-90KN AF Per Bay No. 30 30

Single Suspension H/W & Acc. Per Bay No. 6 6 Spacers suitable for Twin Zebra ACSR

(350mm Spacing) Per Bay No.

26 26

Fire Wedge Connectors suitable for Zebra ACSR to Zebra ACSR Per bay

No. 30 30

b 66KV Bus Coupler Bay No. of bay 1 1

ACSR Moose Conductor per Span Rmtr. 184

Spacers suitable for Twin Zebra ACSR (350mm Spacing) Per Bay

No. 6 6

Fire Wedge Connectors suitable for Zebra ACSR to Zebra ACSR Per bay

No. 24 24

Page 27: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 27

Annexure - 4

Building Detail

Sr. No.

Location

Area X x Y Mtr.

Ht. in Mtr.

Avg Illumination level

Required in LUX

AC 1.5 T

Split

AC 3 T Spli

t

15 A

Plug

5 A Plug

Fan Ex

Fan

DC Point

DC Plug

Portable

Emergency Lighti

ng

Bell

3 ph.wtih neutral 15A test plug

A Control Room

1 Control Room 8.8x8.5 4 300 0 3 4 3 2 0 2 1 1 1 1

2 Battery Room 8.8x8.5 4 100 0 0 0 3 2 4 1 0 0 0 0

3 LV Room 8.8x8.5 4 150 0 0 2 2 2 0 1 0 1 0 1

4 PLCC Room 9.8x5.5 4 300 0 2 2 2 2 0 1 0 1 1 0

5 Store Room 5.8x5.5 4 100 0 0 2 2 1 0 0 0 0 0 0

6 Ramp Slope 2x3.6 4 100 0 0 1 1 0 0 0 0 0 0 0

7 Veranda 2.0x17.9 2.5 70 0 0 0 2 0 0 0 0 0 0 0

8 Office 6.8x8.5 4 300 0 2 2 2 1 0 0 0 0 2 0

9 Toilet Gens 2.2x1.5 4 70 0 0 0 1 0 1 0 0 0 0 0

10 WC 1.5x0.9 4 70 0 0 0 1 0 1 0 0 0 0 0

11 Toilet Ladies 2.5x1.7 4 70 0 0 0 1 0 1 0 0 0 0 0

12 Passage (Corridor) 15.8x2.8 4 70 0 0 0 2 0 0 0 0 1 0 0

13 Ramp Slope 3.6x2 4 100 0 0 1 1 0 0 0 0 0 0 0

14 Veranda 6.2x2.1 2.5 70 0 0 0 2 0 0 0 0 0 0 0

NOTE: Control room out skirt area/porch shall be provided with suitable water tight bulk head fittings as per design.

Page 28: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 28

Annexure - 5

Details of Illumniation for Switch yard Sr. No.

Location Details

1 200kV switch Yard

Upper Bus height 18.5 Mtr

Lower Bus height 12.5 Mtr

Equipments Height from Ground 5.5 Mtr+0.3 Mtr

plinth

Lux level Required for main Equipments - 5.5 Mtr Height 50

Lux level rquired for Other area 20

2 66kV switch Yard

Upper Bus height 10 Mtr

Lower Bus height 7 Mtr

Equipments Height from Ground 4.0 Mtr+0.3 Mtr

plinth

Lux level Required for main Equipments - 4 Mtr Height 50

Lux level rquired for Other area 20

Lux level required for follwing amminities

3 Car Parking Area 20

4 Main Roads (Post Top Lantern) 20

5 Sub Road (Street Light) 20

6 Fencing Light and Spare Area (Street Light) 20

7 Oil Filtration shed 70

8 Garden of Transit Camp (Post Top Lantern) 20

Note:

The area if not applicable as per layout of the project may please be ignored.

Page 29: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 29

: A N N E X U R E - "A" :

Major spares and devices

Particulars Quantity

220 KV Breaker

One number of pole assembly for each type of Breaker 1 No each

SF6 Gas filling kit with various adoptors 1 set

Trip Coil/Close Coil 2 Nos. each

SF6 Gas Bottle (25KG) 2 Nos.

220/66 KV Tranformer

Bushing - HV, LV & MV (neutal) 1 No. each

Set (one no of each ) of Starters, contactors & Relays used in MK box

0

On line DGA kit for monitoring H2 and CO as per technical specifications

0

DG set ( portable three pahse 415V 10 KVA Honda make) 1 set

Welding M/C: Input volt.230-440V(single/two phase), 50Hz, Insulation class A 200 Amp.

1 set

: A N N E X U R E - "B" : Instruments

Computer set with UPS dust cover etc as per technical specifications ( for officer in charge)

1 set

A-4 size mono lasor printer as per technical specifications.( for officer In charge)

1 set

Earth Resistance Tester Digital GE-OHM C make (made in Germany) model no EN 61557/VDE 0413 or updated version with better features.

1 No

Clip on meter AC/DC V/I/OHM - 0-1000V, 0-25A Meco/Rishabh/Motwane Battery backup

1 No

Motor and manual Operated Oil BDV testing Kit –Motwanemake with 0-100kV range, auto cut off feature, with standard ball -cup and measuring gauge as per IS.

1 No

5KV Motor Operated Meggar 1 set

Supply of Dilo Make Gas Kit for operating voltage range 230 V of

Model No :- B143R01

1 Set

: A N N E X U R E - "C" :

: Tools & Tackles :

Earthing Rod (Highly insulated FRP telescopic Earthing/ Discharge Rod. Suitable for 220KV, 18 ft, 3 sections) with cable.

9

Page 30: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 30

Spanner [Ring, Fixed, Box] Fix=10x11,12x13,14x15,,16x17Ring=10x11,12x13,14x15,16x17 Tubular=12x13,14x15,16x17,18x19 Screw driver=827I,927 Nut driver= 7mm

3

Steel Roller - Size 1" 10

Aluminium Roller - Size 4" 5

one/two/three Wheel pulley - Size 1" 2

Winch Machine with Handle - 05 Ton Capacity 2

Hydraulic Press Machine - - 80 Kgs 2

Hand drill Wolf or Equi. Make 1 240 V, hole capacity Capacity :- Hole up to 31 mm , Single Phase

1

Drill Machine - 5/8" Dia Standing Drill machine having 3 Feet Pillar & suitable for making Holes up to ¾”. Motor - Lubi or equi, 1-Ph, 1-HP. Drill Chuck, Arbour, V Belt & Switch

2

Chain pulley block - 5 tonne capacity 2

Wire rope pully block - 02 Tonne 1

Tent- Standard quality water proof Tent made from H.DP.E. Materials with 5 Nos of bamboos Rods and having capacity of 8 to 10 Person to stay & size 10 Ft x 10Ft Multipurpose

1

Water pump Set - 5 HP 2

Water pump Set - 1 HP 2

Crowbar - 1.5 Mtr 1

Crowbar - 1.0 Mtr 1

Heavy hammer - 10Kg 1

Pickaxe ( Trikam) - 2 '' width with Handle 5

Pawda[shovel] - 12 '' width with Handle 5

Axe (Kuhadi) with Handle 5

Sythe (Dharia) with Handle 10

Tar Poline (Tad Patri) size 5

Nylon Rope - 0.5" Dia -100 mtrs 1

Nylon Rope 0.75" Dia - 100 mtrs 1

Nylon Rope - 1" Dia - 100 mtrs 1

Scissor Lift working height up to 8 Mtrs, load Carrying Capacity up to 350 Kg including following Features A. Unique Handle - Pull Mechanism B. Extendable Jack’s for more stability C. Manual Platform lowering Valve D. Emergency Stop at both, Platform and ground controls E. Sensors for opening and closing circuit F. Analog control system

1

Page 31: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 31

Aluminium Ladder - 15 ft. Aluminium folding factory ladder (Heavy duty) made from high tensile aluminium alloy design no 152 AFFL 15 Ft height (4.56 mtrs) specification section= 15/8” X 1.1/4” Steps= 15/8 X 1.1/4 12”Center to Center

2

Telescopic aluminium ladder(3 sections) with platform - 25 ft 1

Oil Drum Lifter Oil Hand pump 1

Cable Drum Lifter 1

Cable Drum 1

Turn Table - Cable Drum 1

Hand cart - 2 tonne capacity With steel body 1

Hot air blower Small Capacity =1.5m3/min, Big Capacity =2.0m3/min

1

Vacumme cleaner - Tornedo/Ureka Forbes or equi. 1

Wooden sleeper - Pine wood sleeper of size 10”X5”X10 feet long

50

SAFETY TOOLS

Safety belt Full body covering and Half body covering

15

Halmet with ISI mark of repute make 10

Hand Gloves Hand gloves of quality as per Is certification 4770 & test potential 7500Volt

6

Gum boot (Pair) - Size 8,9,10. - Standard make 3

220 & 66 KV Breaker

One Set of Gasket for One pole of each type of Breaker 1

Switch Yard / Line Clamp connectors (SPARE)

T-clamp, for twin as well as single moose 10

Spacer cum Damper- 220KV 10

Clamps for each type of breaker 6

CT Clamp - 220 & 66KV 6

Joint sleeve- Alu. Moose conductor 10

Deadend hardware for moose conductor 3

Isolator clamp for 220KV 6

Isolator L-clamp- for 220KV 6

Palm connector- 220KV 6

X'mer bushing clamp (HV/LV/Neutral) 2

Repair Sleeve- moose 5

PG clamp for moose conductor 5

Isolator contacts for each type / make of isolator 6

PI Clamp-twin Morle 3

Earth wire clamp 4

Comealong clamp- moose conductor 3

Hardware - fastners

16/17, 03" Bolt nut 50

18/19, 04" Bolt nut 50

Page 32: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 32

18/19, 03 " Bolt nut 50

21/23, 2.5" Bolt nut 50

21/23, 3" Bolt nut 50

Illumination Luminaries

Energy efficient decorativeTube (spare as provided in cotrol room illumination design)

20

Energy Efficient tube (spare as provided in switch yard illumination design)

20

CFL (spare as provided in illumination design) 20

LED indicating Lamps 22.5 20

Display Boards and others

Single line diagram drawn with radim paint suitable decorated on a board of approx size of 120x90 mmsuitable designed thickness with fixing arrangement in control room wall.

1

Key board with hook for differeint keys of each equipments/panels/cubicles with SLD drawn with color approx size 2'x2'

1

Annexure- "D"

Supply of Furniture, RO Water Filter System, Water Cooler Etc.

Sr. No.

Particulars Quantity

Furniture for 220KV S/S

a) Steel chair "S" type, Overhanging arm with cushion with cane seat/back 1"X 16" gauge round pipe frame

3 Nos.

b) Steel rack of size 30"X36"X15" with three partitions, prepared 20 gauges

2 Nos.

c) Providing Control Room Table modular 5X5 Panta work surface with pedestal CPU Trolley & Key Board tray of Godrej or equivalent

1 No.

d) Office table with SDU & pedestal 5026/3619 Godrej or equivalent +B124

2 Nos.

d) Modular workstations of Godrej make or equivalent 4X2 Panta work surface with pedestal CPU trolley & keyboard Tray or equivalent

2 No.

e) Revolving chair PCH 7001R of Godrej make or equivalent

4 Nos.

1

f) Three seater perforated chair with powder coating(Bench)

1 No.

2 RO water filter system 25Ltr. Capacity 1 No.

Page 33: PART – III Price Bid · CB 2000A 40kA 3s with str and clamp connectors as per Technical spec Set. 6 6 B Supply and Erection of 220kV Switchyard materials as per respective Technical

Sign & seal of Bidder 33

3

Providing & installing SHRIRAM USHA or equivalent make water cooler of 40Ltr./hr. capacity suitable to operate on 230V+10% , 50Hz. Single phase AC supply with hermetically sealed type suction cooled compressor with overload protection confirming to IS 10617(Part-I) with amdt. 1 & 2. Item rate includes all charges including necessary piping of approved make & quality upto designated water supply point.

1 No.