11kV 3x1C Termination – XLPE Cables

Part Nº Cable Range (mm) Insulation O.D. (mm) Oversheath O.D. (mm)

CAN-XTSK-11-70-3X1C 35 - 70 12 - 20 15 - 30

CAN-XTSK-11-185-3X1C 95 - 185 18 - 26 20 - 40

CAN-XTSK-11-400-3X1C 240 - 400 22 - 36 25 - 50

CAN-XTSK-11-800-3X1C 500 - 800 33 - 48 40 - 60

CAN-XTSK-11-1000-3X1C 1000 48 - 60 50 - 70

22kV 3x1C Termination – XLPE Cables

Part Nº Cable Range (mm) Insulation O.D. (mm) Oversheath O.D. (mm)

CAN-XTSK-22-70-3X1C 35 - 70 12 - 25 20 - 40

CAN-XTSK-22-185-3X1C 95 - 185 22 - 36 20 - 40

CAN-XTSK-22-400-3X1C 240 - 400 25 - 40 40 - 60

CAN-XTSK-22-800-3X1C 500 - 800 35 - 52 45 - 70

CAN-XTSK-22-1200-3X1C 1000 - 1200 40 - 65 50 - 80

33kV 3x1C Termination – XLPE Cables

Part Nº Cable Range (mm) Insulation O.D. (mm) Oversheath O.D. (mm)

CAN-XTSK-33-95-3X1C 50 - 95 17 - 33 20 - 40

CAN-XTSK-33-185-3X1C 120 - 185 25 - 38 25 - 50

CAN-XTSK-33-400-3X1C 240 - 400 30 - 45 30 - 54

CAN-XTSK-33-630-3X1C 500 - 630 35 - 55 35 - 70

CAN-XTSK-33-1200-3X1C 800 - 1200 40 - 70 50 - 90

For 3C cables, add a Trifurcation Kit;

11kV Trifurcation – XLPE Cables

Part Nº Cable Range

(mm) O.D. Over Screen Wires

(mm) Oversheath O.D. (mm)

CAN-TRF-11-35-95 35 - 95 18 – 30 33 – 68

CAN-TRF-11-120-185 120 - 185 22 – 37 52 – 93

CAN-TRF-11-240-500 240 - 500 24 – 45 60 – 115

22kV Trifurcation – XLPE Cables

Part Nº Cable Range

(mm) O.D. Over Screen Wires

(mm) Oversheath O.D. (mm)

CAN-TRF-22-35-95 35 - 95 22 – 37 52 – 93

CAN-TRF-22-120-185 120 - 185 24 – 45 60 – 100

CAN-TRF-22-240-500 240 - 500 30 – 60 70 – 110

33kV Trifurcation – XLPE Cables

Part Nº Cable Range

(mm) O.D. Over Screen Wires

(mm) Oversheath O.D. (mm)

CAN-TRF-33-50-95 50 - 95 22 – 37 52 – 93

CAN-TRF-33-120-185 120 - 185 24 – 45 60 – 100

CAN-TRF-33-240-500 240 - 500 30 – 60 80 – 130

11kV 1C Joint – XLPE Cables

Part Nº Cable Range

(mm) Insulation O.D.

(mm) Oversheath O.D.

(mm)

Connector Max. Dimensions (mm)

Diameter Length

CSJ-INT-11-35-70-1C 35 - 70 12 - 20 20 - 40 24 75

CSJ-INT-11-95-240-1C 95 - 240 17 - 30 25 - 45 33 130

CSJ-INT-11-300-400-1C 300 - 400 25 - 40 35 - 50 42 176

CSJ-INT-11-500-630-1C 500 30 - 45 40 - 60 62 238

22kV 1C Joint – XLPE Cables

Part Nº Cable Range

(mm) Insulation O.D.

(mm) Oversheath O.D.

(mm)

Connector Max. Dimensions (mm)

Diameter Length

CSJ-INT-22-35-70-1C 35 - 70 17 - 25 22 - 40 24 75

CSJ-INT-22-95-240-1C 95 - 240 23 - 35 30 - 50 33 130

CSJ-INT-22-300-400-1C 300 - 400 30 - 42 38 - 60 42 176

CSJ-INT-22-500-630-1C 500 33 - 50 42 - 70 62 238

11kV 3C Joint – XLPE Cables

Part Nº Cable Range

(mm) Insulation O.D.

(mm) Oversheath O.D.

(mm)

Connector Max. Dimensions (mm)

Diameter Length

CTJ-INT-11-35-70-3C 35 - 70 12 - 20 40 - 60 24 75

CTJ-INT-11-95-240-3C 95 - 240 17 - 30 45 - 70 33 130

CTJ-INT-11-300-400-3C 300 - 400 25 - 40 65 - 100 42 176

CTJ-INT-11-500-3C 500 30 - 45 65 - 100 62 238

22kV 3C Joint – XLPE Cables

Part Nº Cable Range

(mm) Insulation O.D.

(mm) Oversheath O.D.

(mm)

Connector Max. Dimensions (mm)

Diameter Length

CTJ-INT-22-35-70-3C 35 - 70 17 - 30 40 - 65 24 75

CTJ-INT-22-95-240-3C 95 - 240 22 - 35 60 - 100 33 130

CTJ-INT-22-300-400-3C 300 - 400 25 - 40 65 - 110 42 176

CTJ-INT-22-500-3C 500 33 - 50 70 - 120 62 238

Typical Construction:

All joints and terminations are designed and kitted at Intertech’s

head office in Victoria. We are able to design MV joint and

termination kits to suit most cable designs and specifications.

Large stocks are carried locally and a dedicated technical team

allow us to deliver both, existing products and new designs, on

very short lead times.

CANUSA joint and termination kits are

designed for use with Pfisterer SICON

connectors.

Joints and Terminations are normally

supplied without lugs & links, however,

we can supply Pfisterer’s SICON range

of step-less shear-head connectors or

crimped connectors if preferred.

The SICON range of connectors offer

best-in-class connections through the

use of a two piece shear-head bolt design, conductor contact plate and excellent range

taking capabilities.

Typical Construction:

Pfisterer SICON Shear Process

Head Office

15 Sir Laurence Drive

Phone: +61 3 8770 5500

Fax: +61 3 9773 5666

E-mail: [email protected]

www.intertecheng.com.au V1.00

Intertech Engineering Pty. Ltd.