part no. nominal i.d. nominal o.d. - electrical and ...pub/@eaton/@hyd/documents/content/... · ©...

2

Upload: lamkiet

Post on 10-Nov-2018

218 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Part No. Nominal I.D. Nominal O.D. - Electrical and ...pub/@eaton/@hyd/documents/content/... · © 2013 Eaton All Rights Reserved Printed in USA Document No. E-HOTH-BB001-E1 December
Page 2: Part No. Nominal I.D. Nominal O.D. - Electrical and ...pub/@eaton/@hyd/documents/content/... · © 2013 Eaton All Rights Reserved Printed in USA Document No. E-HOTH-BB001-E1 December

©2013EatonAll Rights ReservedPrinted in USADocumentNo.E-HOTH-BB001-E1December2013

Part No. Nominal I.D. Nominal O.D. Maximum

Operating PressureBurst

PressureBurst to WP Ratio Weight

Minimum Bend Radius

mm in mm in bar psi bar psi ratio LB /100 ft KG /100m in mm

3394-323395-32 51 2 71 2.79 259

3453,7505,000 1035 15,000 4:1

3:1 134 200 25 635

3394-32 & 3395-32 Hose Weight5

Weight in Air Weight in Seawater 2,3

Unfilled Filled 1 Unfilled3

Filled 1

kg/100 m 200 408 -206 2.00 kg/100 m

lbf/100 ft 134 274 -138 1.34 lbf/100 ft

1ReferenceFluidSpecificGravity=1.029ReferenceFluid=208.0kg/100mofhose(139.8lbs./100ftofhose)HoseID(ref)= 2.00in 50.8mm 2Seawater Density=1029kg/m3(64.24lbs./ft3) 3Positivevalueisdownward(sinking).Negativeisbuoyant.4OvershealthOD(ref)= 3.11in 79.0mm5HoseOD(ref)= 2.79in 70.9mm

Note: Only nominal hose and fluid weight are considered. Volumetric expansion, fitting weight, clump weight and dynamic loading are not considered.

Kinked Hose Performance Multiplenewhoseassemblieswerekinkedbyfoldingthehosesuponthemselves,pasttheminimumbendradiusuntilthehosescollapsed/kinked.Thehoseswereallowedtoreturntonaturalshape.ThehoseassembliessubsequentlypassedAPI17Eimpulseandbursttestingattheirratedtestpressures.

Hose Buoyancy Hose Buoyancy with Guardian™ Overlay

Crimp Fitting to Hose Machineminimum:325ton-force(long)(3250kN)with115mm(4.5inch)dielength.

3394-32OVL & 3395-32OVL Hose Weight (with Overlay4)

Weight in Air Weight in Seawater 2,3

Unfilled Filled 1 Unfilled3

Filled 1

kg/100 m 307 515 -197 11.0 kg/100 m

lbf/100 ft 206 346 -132 7.39 lbf/100 ft

Construction • Cover–BlackPolyurethane • Reinforcement – Kevlar®aramidfiber • Core Tube–P40TLOgradeNylon11

End Fittings • 316stainlesssteel(othergradesavailable) • Code62Flange • 2”buttweld • 2”HammerUnion(Fig.1502)

EatonHydraulicsGroupUSA14615LoneOakRoadEdenPrairie,MN55344USATel:952-937-9800Fax:952-294-7722www.eaton.com/hydraulics

EatonHydraulicsGroupEuropeRoutedelaLongeraie71110MorgesSwitzerlandTel:+41(0)218114600Fax:+41(0)218114601

EatonHydraulicsGroupAsiaPacificEatonBuildingNo.7Lane280LinhongRoadChangningDistrict,Shanghai200335ChinaTel:(+8621)52000099Fax:(+8621)22307240