pblock testbox

2
6AG1064-1AA04-0AA0 24.06.03 Bl. 2 1 STV+ STV- IGD+ IGD- L+ T1-T3 P24 0V Preload Thyristor TDB ok ok ok Reset Start Testbox SINAMICS Powerblock/ MM4PX 6AG1064-1AA04-0AA0 Execute Reset T1+/T2- T1+/T3- T2+/T1- T2+/T3- T3+/T1- T3+/T2- IGDok UCEok UCE LS US Imax Imax OK Converter Current Off T1 T2 T3 Thyristor and Preload- Test IGBT-Test Reset T1 T2 T3 X244 X43 TDB-Circuit Current converter LWL-IGD 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Powersupply Preloadcircuit +Thyristorblock IGD-circuit IGBT-AC-Converter and Currentconverter-test external Powersupply 24V / 3A Output ! Input ! grant of a patent or the registration of a utility model or design. ment of damages. All rights are reserved in the event of the without express authority. Offenders are liable to the pay- use of communication of the contents thereof, are forbidden Copying of this Document and giving it to others and the Fall der Patenterteilung oder GM-Eintragung vorbehalten. lungen verpflichten zu Schadensersatz. Alle Rechte fuer den soweit nicht ausdruecklich zugestanden. Zuwiderhand- Verwertung und Mitteilung ihres Inhalts nicht gestattet, Weitergabe sowie Vervielfaeltigung dieser Unterlage, A&D SE S3 Siemens AG Zust. Mitteilung Datum Name Gepr. Datum Bearb. Short description Bestell-Nr. Blatt Testbox SINAMICS Powerblock/ MM4PX * Powersupply Output ! Powersupply Output ! Breitschuh Renner

Upload: asolelpancho

Post on 17-Jul-2016

3 views

Category:

Documents


1 download

DESCRIPTION

Minimanual de testbox

TRANSCRIPT

Page 1: Pblock Testbox

6AG1064-1AA04-0AA0

24.06.03

Bl.2

1

STV+

STV-

IGD+

IGD-

L+

T1-T3

P24

0V

Preload Thyristor TDBok ok ok

Reset Start

Testbox SINAMICS Powerblock/ MM4PX6AG1064-1AA04-0AA0

Execute

Reset

T1+/T2-

T1+/T3-

T2+/T1-

T2+/T3-

T3+/T1-

T3+/T2-

IGDok UCEokUCELSUS

Imax

Imax

OKConverterCurrent

Off

T1 T2 T3

Thyristorand

Preload-

Test

IGBT-Test

Reset

T1

T2

T3

X244 X43

TDB-Circuit Current converter

LWL-IGD

1 23

4 5

6

7

8

9

10

11

12

13

14

PowersupplyPreloadcircuit

+Thyristorblock

IGD-circuit

IGBT-AC-Converterand

Currentconverter-test

external Powersupply24V / 3A

Output !

Input !

gran

t of a

pat

ent o

r th

e re

gist

ratio

n of

a u

tility

mod

el o

r de

sign

.m

ent o

f dam

ages

. All

right

s ar

e re

serv

ed in

the

even

t of t

hew

ithou

t exp

ress

aut

horit

y. O

ffend

ers

are

liabl

e to

the

pay-

use

of c

omm

unic

atio

n of

the

cont

ents

ther

eof,

are

forb

idde

nC

opyi

ng o

f thi

s D

ocum

ent a

nd g

ivin

g it

to o

ther

s an

d th

e

Fal

l der

Pat

ente

rtei

lung

ode

r G

M-E

intr

agun

g vo

rbeh

alte

n.lu

ngen

ver

pflic

hten

zu

Sch

aden

sers

atz.

Alle

Rec

hte

fuer

den

so

wei

t nic

ht a

usdr

ueck

lich

zuge

stan

den.

Zuw

ider

hand

-V

erw

ertu

ng u

nd M

ittei

lung

ihre

s In

halts

nic

ht g

esta

ttet,

Wei

terg

abe

sow

ie V

ervi

elfa

eltig

ung

dies

er U

nter

lage

,

A&D SE S3

Siemens AG

Zust. Mitteilung Datum Name

Gepr.

Datum

Bearb.

Short descriptionBestell-Nr.

Blatt

Testbox SINAMICS Powerblock/ MM4PX

*

Powersupply

Output !

Powersupply

Output !

Breitschuh

Renner

Page 2: Pblock Testbox

5 Start-button, enables firingpulses of thyristors

Currentconvertertest :

choosing Phase T1−:− T3 together with switchT1 / T2 / T3:

LS = lower switch

Reset-button: Reset of currentconverter - LED "red"

Switch: upside = with connected motor

choosing of desired IGBT- transistors

test of preload and thyristor possibleOFF: Powersupply L+ / T1 - T3 / L- is shut down,Switch:

Switch,choosing: US = upper switch

11

Execute-button: 12

10

9

6

(initiated by push button "START"

Preload-LED, on, when OK

RESET-Thyristor-button, Reset of LED and powerenable

Thyristor-LED, on, when thyristor in on-state

TDB-LED, on, when currentconsumption TDB OK

4

3

2

1

5

UCE = upper+lower switch

off = current to low7

green= current OKred = current to high

IGD - LED

UCE - LED, on, when UCE-test OK, must be reseted for each new test8

IGBT− AC−convertertest

When currents are symmetrical, LED is green, when currents are not6 different combinations off currentflow inside the currentconverters

)

releases all optical signals for IGBT-and currentconvertertest

I max- LED L+ : on, when reaching currentsetpoint13

14 I max- LED L- :

Bl.2

2

gran

t of a

pat

ent o

r th

e re

gist

ratio

n of

a u

tility

mod

el o

r de

sign

.m

ent o

f dam

ages

. All

right

s ar

e re

serv

ed in

the

even

t of t

hew

ithou

t exp

ress

aut

horit

y. O

ffend

ers

are

liabl

e to

the

pay-

use

of c

omm

unic

atio

n of

the

cont

ents

ther

eof,

are

forb

idde

nC

opyi

ng o

f thi

s D

ocum

ent a

nd g

ivin

g it

to o

ther

s an

d th

e

Fal

l der

Pat

ente

rtei

lung

ode

r G

M-E

intr

agun

g vo

rbeh

alte

n.lu

ngen

ver

pflic

hten

zu

Sch

aden

sers

atz.

Alle

Rec

hte

fuer

den

so

wei

t ni

cht

ausd

ruec

klic

h zu

gest

ande

n. Z

uwid

erha

nd-

Ver

wer

tung

und

Mitt

eilu

ng ih

res

Inha

lts n

icht

ges

tatte

t,W

eite

rgab

e so

wie

Ver

viel

fael

tigun

g di

eser

Unt

erla

ge,

A&D SE S3

Siemens AG

Zust. Mitteilung Datum Name

Gepr.

Datum

Bearb.

Short descriptionBestell-Nr.

Blatt

24.06.03

6AG1064-1AA04-0AA0

Testbox SINAMICS Powerblock/ MM4PX

Reset: must be reseted, when red

* Powersupply IGBT-AC-converter and currentconvertertest is not concipated

for long on - duration.

When connected to powerblock, the execute-button should not be pressed longer then 5 seconds.

+

6

symmetrical, LED is red, and must be reseted 11 for each new test.

downside = phases shortened to each other

on, when reaching currentsetpoint

Breitschuh

Renner