PC2800LR After Sales Support Now you have purchased a Power Craft product you can rest assured in the knowledge that as well as your 3 year parts and labour warranty you have the added peace of mind of dedicated helplines and email support. 2,800W DUAL VOLTAGE LONG RUN GENERATOR User Guide & Warranty 3 YEAR MANUFACTURER’S WARRANTY CUSTOMER HELPLINE In order to deal with your enquiry as quickly and efficiently as possible, we ask you to send your enquiry by email. Do not forget to include your name, address and a daytime telephone number. Alternatively, you can contact our freephone service hot-line on the number given below. Office hours are as follows: Mon - Fri: 8.00am - 6.00pm, Saturday 8.00am - 2.00pm & Sunday 10.00am - 4.00pm Omega Wolf Ltd Prospect Close, Lowmoor Business Park, Kirkby-In-Ashfield, Nottinghamshire NG17 7LF, UK. UK / NORTHERN IRELAND 08707 323023 REPUBLIC OF IRELAND 1800 481 005 www.omegawolf.com/powercraft Name: Address: Contact Telephone No.: Email: Location of purchase: Fault Description: 2,800W DUAL VOLTAGE LONG RUN GENERATOR PC2800LR If you are requested by the manufacturer to return the item for repair please complete the enclosed section and send it together with your product and your receipt (proof of purchase) to the service address shown below. AFTER SALES SUPPORT MODEL NUMBER: PC2800LR UK / N. IRELAND HELPLINE NO 08707 323023 WEB SUPPORT: www.omegawolf.com/powercraft REP . IRELAND HELPLINE NO 1800 481 005

Upload: matt-robinson

Post on 25-Oct-2015

1.046 views

Category:

Documents


29 download

DESCRIPTION

Powercraft 2200LR Generator User Manual

TRANSCRIPT

Page 1: PC2800LR Generator Manual

PC2800LR

After Sales SupportNow you have purchased a Power Craftproduct you can rest assured in theknowledge that as well as your 3 yearparts and labour warranty you havethe added peace of mind of dedicatedhelplines and email support.

2,800W DUAL VOLTAGELONG RUN GENERATOR

User Guide & Warranty

3YEAR

MANUFACTURER’SWARRANTY

CUSTOMERHELPLINEIn order to deal with your enquiry as quickly and efficiently as possible, we ask you to send your

enquiry by email. Do not forget to include your name, address and a daytime telephone number.

Alternatively, you can contact our freephone service hot-line on the number given below.Office hours are as follows:

Mon - Fri: 8.00am - 6.00pm, Saturday 8.00am - 2.00pm & Sunday 10.00am - 4.00pm

Omega Wolf LtdProspect Close, Lowmoor Business Park,

Kirkby-In-Ashfield, Nottinghamshire NG17 7LF, UK.

UK / NORTHERN IRELAND 08707 323023

REPUBLIC OF IRELAND 1800 481 005

www.omegawolf.com/powercraft

Name:

Address:

Contact Telephone No.:

Email:

Location of purchase:

Fault Description:

2,800W DUAL VOLTAGELONG RUN GENERATOR

PC2800LR

If you are requested by the manufacturer to return the item forrepair please complete the enclosed section and send it together

with your product and your receipt (proof of purchase) to theservice address shown below.

AFTER SALES SUPPORT

MODEL NUMBER: PC2800LR

UK / N. IRELAND HELPLINE NO 08707 323023

WEB SUPPORT: www.omegawolf.com/powercraftREP. IRELAND HELPLINE NO 1800 481 005

Page 2: PC2800LR Generator Manual

02 27

Contents

03 INTRODUCTION04 SAFETY06 COMPONENT IDENTIFICATION07 OPERATION07 Engine switch07 Recoil starter07 Fuel valve08 Choke rod08 Circuit breaker08 Ground terminal09 Oil alert system09 Pilot lamp09 DC Terminals09 DC Circuit Protector10 GENERATOR USE10 Connections to a Building’s Electrical System10 Generator Ground Circuit11 AC Applications11 AC Operation12 DC Operation13 Disconnecting the battery cables14 PRE-OPERATION CHECK14 Engine Oil15 Fuel Recommendation17 STARTING THE ENGINE18 STOPPING THE ENGINE19 MAINTENANCE19 Maintenance Schedule20 Engine Oil Change20 Air Cleaner Service21 Fuel Sediment Cup Cleaning22 Spark Plug Service23 TRANSPORTING/STORAGE25 TROUBLESHOOTING26 SPECIFICATIONS27 WARRANTY CERTIFICATE27 DECLARATION OF CONFORMITY

Warranty

EC DECLARATION OF CONFORMITY

Congratulations! You have made an excellent choice with the purchase of thisQuality product. Our commitment to quality also includes our service. Should you,contrary to expectations, experience defects due to material or manufacturing faults during privateuse within 36 months of the date of purchase we shall be liable for warranty in accordance withstatutory warranty regulations, provided that: - The device was not put to any use other than theintended.- Was not overloaded. - Was not used with the wrong accessories. - Repairs were notcarried out by any other than the authorised workshop. The warranty certificate is only valid inconnection with the receipt. Please keep both in a safe place. The warranty does not affect yourstatutory rights.The product is guaranteed for a period of three years beginning on the day of purchase. Keep yourpurchase receipt safe as proof of the date of purchase. The guarantee period can only be extendedfor the duration of any repair required.During the warranty period, defective devices can be sent FREIGHT PREPAID to the service addressstated at the end of this booklet. We will, at our discretion either repair or exchange the device inaccordance with warranty legislation.Please include the following when sending in your product for repair:1. The receipt (proof of purchase)2. This warranty certificate with your name, address, contact details and a fault descriptioncompleted overleaf.If the original receipt is not enclosed the repair will be charged for in all cases. After the warrantyhas expired you can still send defective devices for repairs FREIGHT PREPAID to the address at theend of this booklet. Quotes as well as repairs after warranty period are to be paid for in all cases.Ensure the product is sent well packed as no responsibility can be accepted for items lost ordamaged in transit. This warranty does not affect your statutory rights.

WARRANTY CERTIFICATE

WA

RRANTY

M

O N T H

S36Year of Manufacture 09/2007 2,800W DUAL VOLTAGE LONG RUN GENERATOR

declare that the design and construction of the following machine, in the formsupplied by us, comply with the requirements of the appropriate EC directives.

Product Description: 2,800W DUAL VOLTAGE LONG RUN GENERATORModel: PC2800LRAppropriate EC directives: 89/336/EEC, 2000/14/EC, 98/37/EC, 73/23/EECIn accordance with the standards: EN 55012 : 2002, EN ISO 3744:1995, ISO 8528-10:1998,

EN 12601:2001, EN 60204-1:1997

Helpline No. UK / Northern Ireland 08707 323023 Rep. Ireland 1800 481 005Web Support: www.omegawolf.com/powercraftModel Number: PC2800LR

Helpline No. UK / Northern Ireland 08707 323023 Rep. Ireland 1800 481 005Web Support: www.omegawolf.com/powercraftModel Number: PC2800LR

We OMEGA WOLF LTD, Kirkby-In-Ashfield, Nottinghamshire, UK

M D IrwinQuality Department 09/2007

Page 3: PC2800LR Generator Manual

26 03

Introduction

Congratulations on choosing to buy aPower Craft product.

By doing so you now have the assurance and peace of mind that comes with purchasing aproduct made by one of Europe’s leading manufacturers.

All products brought to you by Power Craft are manufactured to the highest standards ofperformance and safety, and, as part of our philosophy for customer service and satisfaction,are backed by our comprehensive 3 Year Warranty.

We hope you will enjoy using your purchase for many years to come.

This user’s manual describes the operation and maintenance of the Generator. All informationin this publication is based on the latest product information available at the time of printing.We reserve the right to make changes at any time without notice and without incurring anyobligation. No part of this publication may be reproduced without written permission.

Safety MessageYour safety and the safety of others are very important. We have provided important safetymessages in this manual and on the generator. Please read these messages carefully.

Specification

MODEL PC2800LR

Max.Output (Watts) 2800

Cont. Output (Watts) 2500

Phase Single

Rated Voltage 230V/110V

Rated Frequency 50Hz

DC Output 12V 8.3A

Power Factor 1.0

Engine Single cylinder 4-stroke air-cooled

Horsepower 6.7

Rated Speed 3000rpm

Displacement 200cc

Ignition System TCI

Oil Alert System Yes

Starting System Recoil

Oil Capacity (Litres) 0.6

Fuel tank Capacity (Litres) 15

Net Weight (kg) 47kg

Helpline No. UK / Northern Ireland 08707 323023 Rep. Ireland 1800 481 005Web Support: www.omegawolf.com/powercraftModel Number: PC2800LR

Helpline No. UK / Northern Ireland 08707 323023 Rep. Ireland 1800 481 005Web Support: www.omegawolf.com/powercraftModel Number: PC2800LR

Page 4: PC2800LR Generator Manual

04 25

Safety

Do not connect to a building’s electrical system unless an isolation switch has beeninstalled by a qualified electrician.

Using a generator or an electrical appliance in wet conditions such as rain or snowor near a pool or sprinkler system, or when your hands are wet, could result inelectrocution. Keep the generator dry.

Operator Responsibility• Know how to stop the generator quickly in case of emergency. (See Page 18)• Understand the use of all generator controls, output receptacles and connections.• Be sure that anyone who operates the generator receives proper instruction.

Do not let children operate the generator.

SAFETY INFORMATIONGenerators are designed to give safe and dependable service if operated according to instructions.Read and understand this user’s manual before operating your generator. You can help preventaccidents by being familiar with your generator’s controls and by observing safe operatingprocedures.

Troubleshooting

Helpline No. UK / Northern Ireland 08707 323023 Rep. Ireland 1800 481 005Web Support: www.omegawolf.com/powercraftModel Number: PC2800LR

Helpline No. UK / Northern Ireland 08707 323023 Rep. Ireland 1800 481 005Web Support: www.omegawolf.com/powercraftModel Number: PC2800LR

Page 5: PC2800LR Generator Manual

24 05

Safety

Carbon Monoxide HazardsExhaust contains poisonous carbon monoxide, a colourless and odourless gas. Breathingexhaust can cause loss of consciousness and may lead to death.

If you run the generator in an area that is confined, or even partially enclosed, the air youbreathe could contain a dangerous amounts of exhaust gas. To keep exhaust gas from buildingup, provide adequate ventilation.

Electric Shock HazardsThe generator produces enough electric power to cause a serious shock or electrocution ifmisused.

Using a generator or electrical appliance in wet conditions, such as rain or snow, or near apool or sprinkler system, or when your hands are wet, could result in electrocution. Keep thegenerator dry. Do not operate the generator in rain or snow.

If the generator is stored outdoors, unprotected from the weather, check all electricalcomponents on the control panel, before each use. Moisture or ice can cause a malfunctionor short circuit in electrical components, which could result in electrocution.

Do not connect to a building’s electrical system unless an isolation switch that has beeninstalled by a qualified electrician.

Fire and Burn HazardsThe exhaust system gets hot enough to ignite some materials.

Keep the generator at least 1 meter (3 feet) away from buildings and other equipment duringoperation.

Do not enclose the generator in any structure.

Keep flammable materials away from the generator.

The silencer becomes very hot during operation and remains hot for a while after stoppingthe engine. Be careful not to touch the silencer while it is hot. Let the engine cool beforestoring the generator indoors.

Petrol is extremely flammable and is explosive under certain conditions. Do not smoke orallow flames or sparks where the generator is refueled or where petrol is stored. Refuel in awell-ventilated area with the engine stopped.

Fuel vapours are extremely flammable and may ignite after the engine has started. Make surethat any spilled fuel has been wiped up before starting the generator.

Transporting / storage

1. Drain the carburetor by loosening the drain screw. Drain the petrol into a suitable container.

Petrol is extremely flammable and is explosive under certain conditions. Performthis task in a well ventilated area with the engine stopped. Do not smoke or allowflames or sparks in the area during this procedure.

2. Change the engine oil.3. Remove the spark plug, and pour about a tablespoon of clean engine oil into the cylinder.

Crank the engine several revolutions to distribute the oil, then reinstall the spark plug.

4. Slowly pull the starter grip until resistance is felt. At this point, the piston is coming up on its compression stroke and both the intake and exhaust valves are closed. Storing the engine in this position will help to protect it from internal corrosion.

Helpline No. UK / Northern Ireland 08707 323023 Rep. Ireland 1800 481 005Web Support: www.omegawolf.com/powercraftModel Number: PC2800LR

Helpline No. UK / Northern Ireland 08707 323023 Rep. Ireland 1800 481 005Web Support: www.omegawolf.com/powercraftModel Number: PC2800LR

Page 6: PC2800LR Generator Manual

06 23

Component Identification Transporting / storage

When transporting the generator, turn the engine switch and the fuel valve OFF. Keep thegenerator level to prevent fuel spillage. Fuel vapour or spilled fuel may ignite.

Contact with a hot engine or exhaust system can cause serious burns or fires. Letthe engine cool before transporting or storing the generator.

Take care not to drop or strike the generator when transporting. Do not place heavy objectson the generator.

Before storing the unit for an extended period:

1. Be sure the storage area is free of excessive humidity and dust.2. Service according to the table below:

STORAGE TIME RECOMMENDED SERVICE PROCEDURE TO PREVENT HARD STARTING

Less than 1 month Fill with fresh petrol and add petrol conditioner*.

2 months to 1 yearFill with fresh petrol and add some petrol conditioner*.Drain the carburetor float bowl.Drain the fuel sediment bowl.

1 year or more

Fill with fresh petrol and add some petrol conditioner*.Drain the carburetor float bowl.Drain the fuel sediment bowl.Remove the spark plug. Put a tablespoon of engine oil into the cylinder. Turn theengine slowly with the pull rope to distribute the oil. Reinstall the spark plug.Change the engine oil.After removal from storage, drain the stored petrol into a suitable container, and fillwith fresh petrol before starting.

* Use petrol conditioners that are formulated to extend storage life.Contact your authorised generator dealer for conditioner recommendations.

VOLTMETER

110VOUTLETS

EARTHTERMINAL

FUEL METERFUEL TANK CAP

Record the engine number for your future reference.

Engine serial number:

CIRCUITBREAKER

OIL DRAINPLUG

ENGINEON/OFFSWITCH

230VOUTLETS

CHANGE OVER SWITCH110V/230V

SILENCER

RECOILSTARTER

AIRFILTER

FUEL ON /OFF VALVE

CHOKE LEVER

CHARGING LEADSAND CLIPS

Helpline No. UK / Northern Ireland 08707 323023 Rep. Ireland 1800 481 005Web Support: www.omegawolf.com/powercraftModel Number: PC2800LR

Helpline No. UK / Northern Ireland 08707 323023 Rep. Ireland 1800 481 005Web Support: www.omegawolf.com/powercraftModel Number: PC2800LR

Page 7: PC2800LR Generator Manual

22 07

Operation

Engine SwitchTo start and stop the engine.Switch position:OFF: To Stop the engine.ON: To run the engine after starting.

Recoil StarterTo start the engine. Pull the starter grip lightly until resistance is felt, then pull briskly.

NOTE: Do not allow the starter to snap back against the engine. Return it gently to preventdamage to the starter.

Fuel ValveThe fuel valve is located between the fuel tank and carburetor. When the valve lever is in theON position, fuel is allowed to flow from the fuel tank to the carburetor. Be sure to returnthe lever to OFF after stopping the engine.

Maintenance

Spark Plug ServiceRecommended spark plugs:MP160; BPR6ES (NGK)MP240, MP340, MP390; BPR5ES (NGK)MP270; BP6ES (NGK)

To ensure proper engine operation, the sparkplug must be properly gapped and free of deposits.

If the engine has been running, the exhaust willbe very hot.

Be carefulDo not to touch the silencer.1. Remove the spark plug cap.2. Clean any dirt from around the spark plug base.3. Use the wrench supplied in the tool kit to remove the spark plug.4. Visually inspect the spark plug. Discard it if the insulator is cracked or chipped. Clean the

spark plug with a wire brush if it is to be reused.5. Measure the plug gap with a feeler gauge.

Correct as necessary by carefully bending the side electrode.The gap should be: 0.70-0.80 mm (0.028-0.031 in)

6. Check that the spark plug washer is in good condition, and thread the spark plug in by hand to prevent cross-threading.

8. After the spark plug is seated, tighten with a spark plug wrench to compress the washer.- If installing a new spark plug, tighten 1/2 turn after the spark plug seats to compress thewasher. If reinstalling a used spark plug, tighten 1/8-1/4 turn after the spark plug seats tocompress the washer.

NOTICEThe spark plug must be securely tightened. An improperly tightened spark plug canbecome very hot and could damage the engine. Never use spark plugs that have animproper heat range. Use only the recommended-spark plugs or equivalent.

Helpline No. UK / Northern Ireland 08707 323023 Rep. Ireland 1800 481 005Web Support: www.omegawolf.com/powercraftModel Number: PC2800LR

Helpline No. UK / Northern Ireland 08707 323023 Rep. Ireland 1800 481 005Web Support: www.omegawolf.com/powercraftModel Number: PC2800LR

Page 8: PC2800LR Generator Manual

08 21

Operation Maintenance

Choke LeverThe choke is used to provide an enriched fuel mixture when cold starting. The choke can beopened by moving the choke rod to the ON position and closed by moving the choke rod tothe OFF position.

Circuit BreakerThe circuit breaker will automatically switch OFF if there is a short circuit or a significantoverload of the generator at the socket. lf the circuit breaker is switched OFF automatically,check that the appliance is working properly and does not exceed the rated load capacity ofthe circuit before switching the circuit breaker ON again.

Earth TerminalThe generator earth terminal is connected tothe frame of the generator, on a metalnon-current carrying parts of the generator,and the earth terminals of each socket.

DC Circuit Protector

EarthTerminal

DC 12

CircuitBreaker

1. Unsnap the air filter cover clips, remove the air filter cover, and remove the element.

2. Wash the element in a solution of household detergentand warm water, then rinse thoroughly; or wash in nonflammable or high flash point solvent, Allow the element to dry thoroughly.

3. Soak the element in clean engine oil and squeeze out the excess oil. The engine will smoke during initialstart-up if too much oil is left in the element.

4. Reinstall the air filter element and the cover.

Fuel Sediment Bowl CleaningThe sediment bowl prevents dirt or water, which may be inthe fuel tank, from entering the carburetor. If the enginehas not been run for a long time, the sediment bowl shouldbe cleaned.

1. Turn the fuel valve to the OFF position. Remove the sediment bowl, O-ring, and filter.

2. Clean the sediment bowl, O-ring, and filter in nonflammable or high flash point solvent.

3. Reinstall the filter, O-ring, and sediment bowl.4. Turn the fuel valve ON and check for leaks.

Fuel Valve Sediment Bowl

FuelFilter

O-Ring

SedimentBowl

Helpline No. UK / Northern Ireland 08707 323023 Rep. Ireland 1800 481 005Web Support: www.omegawolf.com/powercraftModel Number: PC2800LR

Helpline No. UK / Northern Ireland 08707 323023 Rep. Ireland 1800 481 005Web Support: www.omegawolf.com/powercraftModel Number: PC2800LR

AIR FILTER COVER

AIR FILTER ELEMENT

ELEMENT

CLIP

CLIP

Page 9: PC2800LR Generator Manual

20 09

OperationMaintenance

Used motor oil may cause skin cancer if repeatedly left in contact with the skin forprolonged periods. Although this is unlikely unless you handle used oil on a dailybasis, it is still advisable to thoroughly wash your hands with soap and water assoon as possible after handling used oil.

Please dispose of used motor oil in a manner that is compatible with the environment.We suggest you take it in a sealed container to your local service station or recyclingcentre for reclamation. Do not throw it in the dustbin or pour it on the ground.

Air filter serviceA dirty air filter will restrict airflow to the carburetor. To prevent carburetormalfunction, service the air filter regularly. Service more frequently whenoperating the generator in extremely dusty areas.

Using petrol or flammable solvent to clean the filter element can cause a fire orexplosion. Use only soapy water or nonflammable solvent.

NOTICENever run the generator without the air filter. Rapid engine wear will result.

Engine oil changeDrain the oil while the engine is warm to assure rapid and complete draining.1. Remove the drain plug and sealing washer, oil filler cap, and drain the oil.2. Reinstall the drain plug and sealing washer. Tighten the plug securely.3. Refill with the recommended oil and check the level.Oil capacity: 0.6 Litres

Oil Alert SystemThe Oil Alert system is designed to prevent engine damage caused by an insufficient amountof oil in the crankcase. Before the oil level in the crankcase can fall below a safe limit, the OilAlert system will automatically shut down the engine (the engine switch will remain in theON position).

Pilot LampThe pilot lamp is illuminated when the generator is operating normally.

DC TerminalsThe DC terminals may ONLY be used for charging 12 volt automotive type batteries.The terminals are coloured red to identify the positive (+) terminal and black to identify thenegative (-) terminal. The battery must be connected to the generator DC terminals with theproper polarity (battery positive to generator red terminal and battery negative to thegenerator black terminal.)

DC Circuit ProtectorThe DC circuit protector automatically shuts off the DC battery charging circuit when thegenerator is overloaded, when there is a problem with the battery or the connections betweenthe battery and the generator are incorrectly connected.

DC Circuit Protector

EarthTerminal

DC 12

CircuitBreaker

Helpline No. UK / Northern Ireland 08707 323023 Rep. Ireland 1800 481 005Web Support: www.omegawolf.com/powercraftModel Number: PC2800LR

Helpline No. UK / Northern Ireland 08707 323023 Rep. Ireland 1800 481 005Web Support: www.omegawolf.com/powercraftModel Number: PC2800LR

Page 10: PC2800LR Generator Manual

10 19

Generator Use

Connections to a Building’s Electrical SystemConnections for standby power to a building’s electrical system must be made by a qualifiedelectrician. The connection must isolate the generator power from utility power, and mustcomply with all applicable laws and electrical codes.

Improper connections to a building’s electrical system can allow electrical current from thegenerator to back feed into the utility lines. Such back feed may electrocute utility companyworkers or others who contact the lines during a power cut. Consult the utility company or aqualified electrician.

Improper connections to a building’s electrical system can allow electrical current from theutility company to back feed into the generator. When utility power is restored, the generatormay explode, burn, or cause fires in the building’s electrical system.

Generator Earth CircuitsPortable generators have a system earth that connects the generator frame components tothe ground terminals in the AC output receptacles.

The system earth is not connected to the AC neutral wire.

The earth terminal can be used to earth the generator or bond the frame of the generatorto the frame of a vehicle, but only if it is required by local law or electrical code. Before usingthe earth terminal consult a qualified electrician or electrical inspector for regulations.

Maintenance

Periodic maintenance and adjustment is necessary to keep the generator in good operatingcondition. Perform the service and inspection at the intervals shown in the MaintenanceSchedule below.

Exhaust gas contains poisonous carbon monoxide. Shut off the engine before performing anymaintenance. If the engine must be run, make sure the area is well ventilated.

MAINTENANCE SCHEDULE

(1) Service more frequently when used in dusty areas.(2) These items should be serviced by an authorised agent. Contact the helpline.(3) For frequent use, log hours of operation to determine proper maintenance

intervals.

Helpline No. UK / Northern Ireland 08707 323023 Rep. Ireland 1800 481 005Web Support: www.omegawolf.com/powercraftModel Number: PC2800LR

Helpline No. UK / Northern Ireland 08707 323023 Rep. Ireland 1800 481 005Web Support: www.omegawolf.com/powercraftModel Number: PC2800LR

Page 11: PC2800LR Generator Manual

18 11

Generator UseStopping the engine

In an emergency:1. To stop the engine in an emergency, turn the engine switch to the OFF position. See step 3.In normal use:1. Turn the AC circuit breaker to the OFF position.2. Disconnect all electrical loads from panel receptacles.

Disconnect DC battery charging cables.3. Turn the engine switch to the OFF position.4. Turn the fuel valve to the OFF position.

STOPPING THE ENGINE

DC Circuit Protector

EarthTerminal

DC 12

CircuitBreaker

AC ApplicationsBefore connecting an appliance or power cord to the generator;Make sure that it is in good working order. Faulty appliances or power cords can create apotential for electrical shock.

If an appliance begins to operate abnormally, becomes sluggish or stops suddenly, turn it offimmediately. Disconnect the appliance, and determine whether the problem is the appliance,or if the rated load capacity of the generator has been exceeded.

Make sure that the electrical rating of the tool or appliance does not exceed that of thegenerator, Never exceed the maximum power rating of the generator. Power levels betweenrated and maximum may be used for no more than 5 minutes.

NOTICESubstantial overloading will trip the circuit breaker. Exceeding the time limit formaximum power operation or slightly overloading the generator may not switchthe circuit breaker OFF, but will shorten the service life of the generator.

Limit operation requiring maximum power to 5 minutes.Maximum power is: See specifications.For continuous operation, do not exceed the rated power.Rated power is: See specifications.In either case, the total power requirements (watts) of all appliances connected must beconsidered. Appliance and power tool manufactures usually list rating information near themodel number or serial number.

AC Operation1. Start the engine.2. Switch ON the AC circuit breaker.3. Plug in the appliance.

Most motorised appliancesrequire more than their ratedwattage for startup.

Do not exceed the current limit specified for any one socket. If an overloaded circuit causesthe AC circuit breaker to switch OFF, reduce the electrical load on the circuit, wait a few minutesand then reset the circuit-breaker.

Helpline No. UK / Northern Ireland 08707 323023 Rep. Ireland 1800 481 005Web Support: www.omegawolf.com/powercraftModel Number: PC2800LR

Helpline No. UK / Northern Ireland 08707 323023 Rep. Ireland 1800 481 005Web Support: www.omegawolf.com/powercraftModel Number: PC2800LR

Page 12: PC2800LR Generator Manual

DC operationThe DC terminals may ONLY be used for charging 12 volt automotive-type batteries.

NOTE: To operate the battery charging facility, it is necessary to switch the Circuit breakersto the off position. Charging will not occur unless this is done.

Connecting the battery cables:

1. Before connecting charging cables to a battery that is installed in a vehicle, disconnect thevehicle’s earthed battery cable.

The battery gives off explosive gases; keep sparks, flames and cigarettes away. Provide adequate ventilation when charging or using batteries.

2. Connect the positive (+) battery cable to the battery positive (+) terminal.

3. Connect the other end of the positive (+) battery cable to the generator positive (+) terminal.

4. Connect the negative (-) battery cable to the battery negative (-) terminal.

5. Connect the other end of the negative (-) battery cable to the generator negative (-) terminal.

6. Start the generator.

NOTICEDo not start the vehicle while the battery charging cables are connected and thegenerator is running. The vehicle or the generator may be damaged.

An overloaded DC circuit, excessive current draw by the battery, or wiring problem will tripthe DC circuit protector (PUSH button extends out). If this happens, wait a few minutes beforepushing in the circuit protector to resume operation. If the circuit protector continues to goOFF, discontinue charging and contact the helpline.

Generator Use Starting the engine

STARTING THE ENGINE1. Make sure to disconnect all electrical loads from panel receptacles. The generator may be

difficult to start if a load is connected.2. Turn the fuel valve to the ON position.3. The automatic choke will be closed if the engine is cold. If you want to operate the choke

manually, move the choke lever out of the OFF position.4. Start the engine, with recoil starter:

Turn the engine switch to the ON position.Pull the starter grip lightly until resistance is felt, then pull briskly.

NOTICEDo not allow the starter grip to snap back against the engine.Return it gently to prevent damage to the starter or housing.

5. If you have manually closed the choke, move it to the OPEN position as the enginewarms up.

12 17

DC Circuit Protector

EarthTerminal

DC 12

CircuitBreaker

Helpline No. UK / Northern Ireland 08707 323023 Rep. Ireland 1800 481 005Web Support: www.omegawolf.com/powercraftModel Number: PC2800LR

Helpline No. UK / Northern Ireland 08707 323023 Rep. Ireland 1800 481 005Web Support: www.omegawolf.com/powercraftModel Number: PC2800LR

Page 13: PC2800LR Generator Manual

Generator UsePre-operation check

Running the engine with persistent pinking is misuse, and the Manufacturer’s Warranty doesnot cover parts damaged by misuse.

Oxygenated FuelsSome petrols are being blended with alcohol or an ether compound to increase the octane.These petrols are collectively referred to as oxygenated fuels. If you use an oxygenated fuel,be sure its pump octane rating is 86 or higher.

Ethanol (ethyl or grain alcohol)Petrol containing more than 10% ethanol by volume may cause starting and/or performanceproblems.

Methanol (methyl or wood alcohol)Petrol containing methanol must contain solvents and corrosion inhibitors to protect the fuelsystem. Petrol containing more than 5% methanol by volume may cause starting and/orperformance problems and may damage metal, rubber and plastic parts of your fuel system.

MTBE (methyl tertiary butyl ether)You may use petrol containing up to 15% MTBE by volume.

Before using an oxygenated fuel, try to confirm the fuel’s contents. Some states require thisinformation to be posted on the pump. If you notice any undesirable operating symptoms,switch to a conventional unleaded petrol. Fuel system damage or performance problemsresulting from the use of an oxygenated fuel are not the responsibility of the manufacturerand are not covered under warranty.

NOTICEOxygenated fuels can damage paint and plastic. Be careful not to spill fuel whenfilling your fuel tank. Damage caused by spilled fuel is not covered under warranty.

16 13

Disconnecting the battery cables:1. Stop the engine.2. Disconnect the negative (-) battery cable from the generator negative (-) terminal.3. Disconnect the other end of the negative (-) battery cable from the battery negative (-)

terminal.4. Disconnect the positive (+) battery cable from the generator positive (+) terminal.5. Disconnect the other end of the positive (+) battery cable to the battery positive (+) terminal.6. Connect the vehicle earth cable to the battery negative (-) terminal.7. Reconnect the vehicle earth battery cable.

DC Circuit Protector

EarthTerminal

DC 12

CircuitBreaker

Helpline No. UK / Northern Ireland 08707 323023 Rep. Ireland 1800 481 005Web Support: www.omegawolf.com/powercraftModel Number: PC2800LR

Helpline No. UK / Northern Ireland 08707 323023 Rep. Ireland 1800 481 005Web Support: www.omegawolf.com/powercraftModel Number: PC2800LR

Page 14: PC2800LR Generator Manual

Pre-operation check

Engine oil

NOTICEEngine oil is a major factor affecting engine performance and service life. Non-detergent and 2-stroke engine oils will damage the engine and are not recommended.

Check the oil level BEFORE EACH USE with the generator on a levelsurface with the engine stopped.SAE 10W-30 is recommended for general, all-temperature use.Other viscosities shown in the chart may be used when the averagetemperature in your area is within the indicated range.1. Remove the oil filler cap and wipe the dipstick clean.2. Check the oil level by inserting the dipstick into the filler neck without screwing it in.3. If the level is low, fill to the top of the oil filler neck with the recommended oil.

Pre-operation check

14 15

Fuel Recommendation1. Check the fuel level gauge.2. Refill the tank if the fuel level is low. Do not fill above the shoulder of the fuel strainer.

Petrol is extremely flammable and is explosive under certain conditions. Refuel in a well-ventilated area with the engine stopped. Do not smoke or allow flames

or sparks in the area where the engine is refueled or where petrol is stored. Do not overfill the fuel tank (there should be no fuel in the filler neck). After refueling,

make sure the tank cap is closed properly and securely. Be careful not to spill fuel when refueling. Spilled fuel or fuel vapour may ignite. If any fuel is spilled, make sure the area is dry before starting the engine.

Avoid repeated or prolonged contact with skin or breathing of vapour. KEEP OUT OF REACH OF CHILDREN.

Fuel tank capacity: 15 Litres

Use petrol with a pump octane rating of 86 or higher.

We recommend unleaded petrol because it produces fewer engine and spark plug depositand extends exhaust system life.

Never use stale or contaminated petrol or oil/petrol mixture. Avoid getting dirt or water inthe fuel tank.

Occasionally you may hear light sparks knocks or springing, (metallic rapping noise) whileoperating under heavy loads. This is no cause for concern.

Pinking is a metallic tapping noise that can occur if poor or incorrect fuel is used or if theignition timing is not set correctly.

If pinking occurs at a steady engine speed, under normal load, change brands of petrol.lf pinking persists, contact the helpline.

NOTICERunning the engine with persistent pinking can cause engine damage.

FUEL TANK CAP FUEL STRAINER SHOULDER

FUEL LEVEL GAUGE

Helpline No. UK / Northern Ireland 08707 323023 Rep. Ireland 1800 481 005Web Support: www.omegawolf.com/powercraftModel Number: PC2800LR

Helpline No. UK / Northern Ireland 08707 323023 Rep. Ireland 1800 481 005Web Support: www.omegawolf.com/powercraftModel Number: PC2800LR