DX-coil and humidifier VKM–GM series VKM–G series DX-coil NEW Combined Air Conditioning and Ventilation for Energy Efficiency and Comfort Heat Reclaim Ventilation VKM-G(M) series Combined Air Conditioning and Ventilation for Energy Efficiency and Comfort PCH0439 The specifications, designs, and information in this brochure are subject to change without notice. All rights reserved Printed in Japan 12/04/000 c Dealer Head Office: Umeda Center Bldg., 4-12, Nakazaki-Nishi 2-chome, Kita-ku, Osaka, 530-8323 Japan Tokyo Office: JR Shinagawa East Bldg., 18-1, Konan 2-chome, Minato-ku, Tokyo, 108-0075 Japan http://www.daikin.com/global/ 1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced. 2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided and choose an outdoor unit with anti-corrosion treatment. Cautions on product corrosion Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion. Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorized parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion. Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings. For any inquiries, contact your local distributor. All Daikin Industries locations and subsidiaries in J apan have received environmental management system standard ISO 14001 certification. Daikin Industries, Ltd. Domestic Group Certificate Number. EC99J2044 ISO 14001 is the standard defined by the International Organization for Standardization (ISO) relating to environmental management systems. Our group has been acknowledged by an internationally accredited compliance organisation as having an appropriate programme of environmental protection procedures and activities to meet the requirements of ISO 14001. About ISO 14001 The air conditioners manufactured by Daikin Industries have received ISO 9001 certification for quality assurance. Certificate Number. JMI-0107 JQA-0495 JQA-1452

Upload: truongnhu

Post on 26-Aug-2018

230 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: PCH0439 - Daikin | The World's No. 1 Air Conditioning …M)_Series_-_(PCH0… · Combined Air Conditioning and ... The specifications, designs, and information in this brochure are

DX-coil and humidifier VKM–GM seriesVKM–G seriesDX-coil

NEW

Combined Air Conditioning and Ventilationfor Energy Efficiency and Comfort

H e a t R e cla im V e ntila tio n

V K M -G (M ) s e r ie s

Combined Air Conditioning and Ventilationfor Energy Efficiency and Comfort

PCH0439

The specifications, designs, and information in this brochure are subject to change without notice.

All rights reservedPrinted in Japan 12/04/000c

DealerHead Office:Umeda Center Bldg., 4-12, Nakazaki-Nishi2-chome, Kita-ku, Osaka, 530-8323 Japan

Tokyo Office:JR Shinagawa East Bldg., 18-1, Konan2-chome, Minato-ku, Tokyo, 108-0075 Japan

http://www.daikin.com/global/

1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided and choose an outdoor unit with anti-corrosion treatment.

Cautions on product corrosion

Warning Ask a qualified installer or contractor to install this product. Do not try to install the product yourself. Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or contractor to install those parts and accessories. Use of unauthorized parts and accessories or improper installation of parts and accessories can result in water or refrigerant leakage, electrical shock, fire or explosion.Read the User's Manual carefully before using this product. The User's Manual provides important safety instructions and warnings. Be sure to follow these instructions and warnings.

For any inquiries, contact your local distributor.

All Daikin Industries locations and subsidiaries in Japan have received environmental management system standard ISO 14001 certification.

Daikin Industries, Ltd.Domestic GroupCertificate Number. EC99J2044

ISO 14001 is the standard defined by the International Organization for Standardization (ISO) relating to environmental management systems. Our group has been acknowledged by an internationally accredited compliance organisation as having an appropriate programme of environmental protection procedures and activities to meet the requirements of ISO 14001.

About ISO 14001The air conditioners manufactured by Daikin Industries have received ISO 9001 certification for quality assurance.

Certificate Number. JMI-0107JQA-0495JQA-1452

Page 2: PCH0439 - Daikin | The World's No. 1 Air Conditioning …M)_Series_-_(PCH0… · Combined Air Conditioning and ... The specifications, designs, and information in this brochure are

Lineup

Efficient outdoor air introduction and temperature adjustment to suit conditions indoors. This is realized by heat exchanger and energy saving technology unique to Daikin. The lineup now includes models with a humidifier, responding to diversifying customer requirements. The features you expect from Daikin are there. The DX-coil contributes to the prevention of cold airflow hitting people directly during heating operation. High static pressure enhances design flexibility. All these cutting-edge technologies are packed in an integrated compact body. Daikin, the top provider of high quality indoor air, offers even more comfortable environment.

HRV (VKM) introduces fresh outdoor air with minimum heat losses, while a wide variety of features respond to customer requirements.

Efficient outdoor air introduction is possibleDuring simultaneous heating and humidifying operation.

Type

DX-Coil & Humidifier

DX-Coil

500

VKM50GMV1

VKM50GV1

1000

VKM100GMV1

VKM100GV1

800

VKM80GMV1

VKM80GV1

Airflow

Components of Indoor Air Quality

HRV(VKM)

The new HRV lineup features the DX-coil in response torecently diversifying outdoor air introduction requirements.

HumidifierHumidifier

DX-coil DX-coil

High static pressureHigh static pressure

New features

The lineup now includes models with a humidifier, in respone to diversifying customer requirements.

The HRV features DX-coil that contributes to the prevention of cold airflow hitting people directly during heating operation, due to the after-cool, after-heat operations done beforehand.

Higher external static pressure means enhanced design flexibility.

Ventilation Humidification

1 2

Page 3: PCH0439 - Daikin | The World's No. 1 Air Conditioning …M)_Series_-_(PCH0… · Combined Air Conditioning and ... The specifications, designs, and information in this brochure are

ø200Pipe

length

Air flow rate (m3/h)

Operating air flow rate range

400 500

20m

0

70

Ultra High

700

Low50

80

350

600

40m

60

VKM50GMV1

60m

80m

300

100

400

Exte

rnal

sta

tic p

ress

ure

(Pa)

Exchange efficiency

100 300

200

150

90 (%)

200

250

High

Enthalpy exchange efficiency (heating)

Temperature exchange efficiencyEnthalpy exchange efficiency (cooling)

Efficient fan performance produces a high static pressureDesign flexibility

Unique control system

Design flexibility

A compact unit packed with Daikin’s cutting-edge technologies

Independent operation possible

Operable outdoor temperature down to –15°C

Quiet operation

Independent operation of HRV (VKM) type indoor unit is possible (on/off control only) by connecting an optional remote controller.

If the outdoor air suction temperature falls below –10°C, the unit changes to intermittent operation to prevent freezing of the heat exchanger element and dew condensation within the unit.

Intermittent operation A thermistor (standard equipment) within the unit detects the outdoor air temperature. Unit operation varies according to the detected temperature.

Reduced pressure loss and quieter operation internally lowers the noise output of the VKM50GMV1 system to 35/36 dB (220–240 V, 50 Hz).

The heat exchange element uses a High Efficiency Paper (HEP) that has superior moisture-absorption and humidifying properties and doubles the current efficiency of moisture absorption. The heat exchange unit speedily recovers heat contained as latent heat (vapor). The element is made of a material with superior flame-resistant properties and is treated with an anti-molding agent.

Utilizing the principle of capillary action, water is permeated throughout the humidifier element. The heated air from the DX-coil goes through the humidifier and absorbs the moisture.

Humidifier element

NEW

NEWNEW

NEW

NEW

Proprietary Developed HEP Element

Float switchSolenoidvalve

water

Drain

AIRFLOW SA

Drain pan

Improvements to the fan, including the use of multi-arc blades, a thinner scroll and optimized fan scroll angle, help to boost efficiency.

Dramatically higher static pressure is achieved due to improved fan performance. This reduces limitations on unit placement and allows more flexibility in duct design.

NEW

Stru

ctur

e

3

Feat

ures

4

OA(Fresh air fromoutdoors)

SA(Supply air to room)

EA(Exhaust air to outdoors)

RA(Return airfrom room)

Air Supply FanElectronics Box

(Control box)

Exhaust FanHeat Exchanger Elements

DamperDamper Motor

DX-coil(Direct expansion coil)

NEW

The use of multiple, overlapping arc-shaped fan blades makes it possible to optimize the chord length and blade-outlet angle. This results in higher static pressure and quieter operation over the entire usage range.

Multi-arc blades

α

θ

Higher static pressureand reduced noise

The use of a thinner scroll makes it possible to rectify the rotating currents within the scroll.

Resin scroll

Rotating currentsfor reduced loss

In addition to increasing the scroll wrap angle θ and boosting the static pressure, the outflow angle α has been optimized to reduce pressure loss in the outflow area.

Fan scroll angle

Higher static pressureand reduced pressure loss

The fan diameter has been increased and the blade width optimized to suit, resulting in higher static pressure.

Double suction

Higher staticpressure

The VRV IIoutdoor unit

Indoor unit remote control

Indoor unit remote control

Indoor unit remote control

HRV (VKM) HRV (VKM) HRV (VKM)

30.6°C62% RH 27.4°C

63% RH

26°C50% RH

Integrally-formed liner

Indoor

SA

RA

Outdoor

32°C70% RH

Integrally-formed liner

Temperatureand humidity

RA

SA

Operation of the heat exchanger element

Page 4: PCH0439 - Daikin | The World's No. 1 Air Conditioning …M)_Series_-_(PCH0… · Combined Air Conditioning and ... The specifications, designs, and information in this brochure are

Integrated system includes ventilation and humidifying operations

Easy installation + Space saving

Easy operationVentilation, cooling/heating and humidifying are possible with one remote controller.

Indoor unit connectable to up to 130% of the capacity of the outdoor units

Design flexibility

Energy saving

Energy saving

Night Purge Operation

Automatic changeover to efficient operation patterns

Energy savingEfficient outdoor air introduction with heat exchangerand cooling/heating operation

Night purge is an energy-conserving function that works at night when air conditioners are off. By ventilating rooms containing office equipment that raises the room temperature, night purge reduces the cooling load when air conditioners are turned on in the morning.• Night purge only works to cool and if connected to

Building Multi or VRV systems. • Night purge is set to “off” in the factory settings, so if

you wish to use it, request your dealer to turn it on.

Operation automatically changes to the optimum pattern to suit conditions.

NEW

NEW

NEW

NEW

Rather than using separate ventilation and humidifying components, the system incorporating HRV (VKM) integrates all functions, reducing the total number of indoor units and facilitating a far simpler system. The installation space becomes smaller and the labor required for installation and maintenance is reduced significantly.

Various air conditioner functions can be managed using a single remote control. This makes it easy to obtain high-quality and energy-efficient outdoor air treatment.

Feat

ures

5

Feat

ures

6

Design flexibilitySlim design

The slim design of only 387 mm in height enables installation inside ceilings with less than 407 mm of clearance.

Heatsources

Purge

n Indoor unit with outdoor air treatmentHeating and cooling

+

+heat recovery

humidifying

–5 0 5 10 15 20Dry bulb temperature (°CDB)

25 30 35 40

Rel

ativ

e hu

mid

ity (%

)

20

40

6080100

Effect of full heat exchangeEffect of full heat exchange

Effect of full heat exchangeEffect of cooling

Outdoor air temperature in summer

Indoor temperature during heatingIndoor temperature during cooling

Outdoor air temperature in winter Effect of heatingEffect of heating

Effect of humidification

The VRV IIoutdoor unit

Indoor unitremote control

Link connection

Control of the HRV (VKM) type indoor unit is managed using the remote controller of the standard indoor units connected.

During group control operation, the unit has a capacity equivalent to two standard indoor units. Up to 16 standard indoor units can be connected at once.

l Conventional system

l New systemThe VRV IIoutdoor unit

Standard indoor unitHRV (VKM)

HRV (VKM)

Standard indoor unit

HRV Humidifier(Field supply)Outdoor

unit

Ventilation, air conditioning,and humidifying in a single system

One fewerunit!

Using outdoor air, the temperature can be brought near room temperature with minimal cooling capacity through the use of outdoor air.

Exhaust fan

Air supply fan DX-coil (cooling)

DamperHeat exchanger element

(heat recovery)

EA

OA

RA

SA

HumidifyingDX-coil (heating)

Heat exchanger element (heat recovery)

EA

OA

RA

SA

EA

OA

RA

SA

Cooling In between (bypass ventilation) Heating

Automaticchangeover

Automaticchangeover

387 mm

Page 5: PCH0439 - Daikin | The World's No. 1 Air Conditioning …M)_Series_-_(PCH0… · Combined Air Conditioning and ... The specifications, designs, and information in this brochure are

Model Line Up

Clean

7

Mod

el L

ine

Up

8

ø250Pipe

length

Air flow rate (m3/h)

500

Ultra High 50

200

40mLow

300

400

100 60m

6000

200

80

1000

100m

60

70

20m

VKM80GMV1

800

400

High 80m

90 (%)

Exte

rnal

sta

tic p

ress

ure

(Pa)

Operating air flow rate range

Enthalpy exchange efficiency (heating)

Enthalpy exchange efficiency (cooling)

Temperature exchange efficiency

Air flow rate (m3/h)

ø250Pipe

length100m

1200400

20m

60m

200

70

60

600 1000

80m

0

40m

Ultra High

Low100

200

500

300

High

800

VKM100GMV190 (%)

400

80

Exte

rnal

sta

tic p

ress

ure

(Pa)

Operating air flow rate range

Exchange efficiencyExchange efficiencyExchange efficiency

Exchange efficiencyExchange efficiencyExchange efficiency

Enthalpy exchange efficiency (cooling)

Enthalpy exchange efficiency (heating)

Temperature exchange efficiencyø200Pipe

length

Air flow rate (m3/h)

Operating air flow rate range

400 500

20m

0

70

Ultra High

700

Low50

80

350

600

40m

60

VKM50GMV1

60m

80m

300

100

400

Exte

rnal

sta

tic p

ress

ure

(Pa)

100 300

200

150

90 (%)

200

250

High

Enthalpy exchange efficiency (heating)

Temperature exchange efficiencyEnthalpy exchange efficiency (cooling)

Air flow rate (m3/h)

ø250Pipe

length

40m

80m

60m

100m

VKM100GV1

20m

1200400200

70

60

600 10000

Ultra High

Low100

200

500

300

High

800

90 (%)

400

80

Exte

rnal

sta

tic p

ress

ure

(Pa)

Operating air flow rate range

Enthalpy exchange efficiency (cooling)

Enthalpy exchange efficiency (heating)

Temperature exchange efficiencyø200Pipe

length

Air flow rate (m3/h)

20m

40m

60m

80m

Operating air flow rate range

400 5000

70

Ultra High

700

Low

50

80

350

600

60300

100

400

Exte

rnal

sta

tic p

ress

ure

(Pa)

100 300

200

150

90 (%)

200

250

High

VKM50GV1Enthalpy exchange efficiency (heating)

Temperature exchange efficiencyEnthalpy exchang efficiencye (cooling)

ø250Pipe

length

Air flow rate (m3/h)

80m

20m

100m

60m40m

VKM80GV1

500

Ultra High 50

200

Low

300

400

100

6000

200

80

1000

60

70

800

400

High

90 (%)

Exte

rnal

sta

tic p

ress

ure

(Pa)

Operating air flow rate range

Enthalpy exchange efficiency (heating)

Enthalpy exchange efficiency (cooling)

Temperature exchange efficiency

Air supply

Normalventilation fanAir exhaust

HRV (VKM)Portion of fresh-up operation

ex. Office

Fresh-up OperationThe user can select between two fresh-up modes using the remote controller.

Preventing Dust from Falling with Directly Mounted Ducts

A sign is displayed on the remote controller when the air filter needs cleaning.

OFF Dust

W i t h C o m p e t i t o r s ' P r o d u c t sWhen conventional total heat exchange units, which are independently operated using a dedicated remote controller, are directly connected by a duct, there is a possibility of dust falling from the air filter of the indoor unit when the air conditioner is OFF.

W ith the H R V (V K M )When the HRV (VKM) is operating independently, the fan in an interlocked indoor unit continues turning, so dust does not fall from the air filter.

Blowing mode No dust is blown out.

S upply F re s h-up: Raising the air supply maintains proper room pressure to prevent back-flow of toilet/kitchen odors or moisture inflow.

E x ha us t F re s h-up: Raising exhaust air decreases room pressure to prevent the leaking of odors or floating bacteria into other rooms.

Portion of exhaust operation

Air supply

Air exhaust

Sick room Floor area

ex. Hospital

HRV (VKM)VKM50GMV1 VKM80GMV1 VKM100GMV1

DX-Coil & Humidifier (VKM50GMV1, VKM80GMV1, VKM100GMV1)

VKM50GV1 VKM80GV1 VKM100GV1

DX-Coil (VKM50GV1, VKM80GV1, VKM100GV1)

Page 6: PCH0439 - Daikin | The World's No. 1 Air Conditioning …M)_Series_-_(PCH0… · Combined Air Conditioning and ... The specifications, designs, and information in this brochure are

SpecificationsD

imen

sion

s

9

Spec

ifica

tions

10

4-14 x 40 oval holeHanger bracket

4-14 x 40 oval holeHanger bracket

Supply air to roomSA

Return air from roomRA

Supply air to roomSA

Return air from roomRA

(For humidifier) *1Maintenance cover(Natural evaporative type) *1Humidifier

Solenoid valve *1

(For humidifier)Maintenance cover *2

(Natural evaporative type) *2Humidifier

Solenoid valve *2

EA

(Outdoor air)Fresh air from outdoors

Exhaust air to outdoors

OA

EA

(Outdoor air)Fresh air from outdoors

Exhaust air to outdoors

OA

Control box

Maintenance Cover

Mor

e th

an 6

00

hatchInspection

hatchInspection

Control box

Maintenance Cover

Mor

e th

an 6

00

hatchInspection

hatchInspection

the air filters, fans (and humidifier)Maintenance space for the heat exchanger elements

140 (In case of n600 inspection hatch)360 (In case of n450 inspection hatch)

the air filters, fans (and humidifier)Maintenance space for the heat exchanger elements

140 (In case of n600 inspection hatch)360 (In case of n450 inspection hatch)

High efficiency filter (option)

High efficiency filter (option)

Liquid pipe connectionAir filters

(PT3/4 male screw)

(ø12.7)

(ø6.4)

connectionGas pipeHeat exchanger elements

Drain outlet

Liquid pipe connectionAir filters

(PT3/4 male screw)

(ø12.7)

(ø6.4)

connectionGas pipeHeat exchanger elements

Drain outlet

(ø6.4C1220T)Feed water connection port *1

(ø6.4C1220T)Feed water connection port *2

of the heat exchanger elements.Note *1. VKM50GMV1 only.

The high effciency filter (option) can be attached to the SA surface*(n450 or n600) at the service side of filters and elements.Be sure to provide two inspection hatch.*The specification subject to change without notice.*

of the heat exchanger elements.Note *2. VKM80/100GMV1 only.

The high effciency filter (option) can be attached to the SA surface*(n450 or n600) at the service side of filters and elements.Be sure to provide two inspection hatch.*The specification subject to change without notice.*

Note: 1. Cooling and heating capacities are based on the following conditions. Fan is based on High and Ultra-high.The figures in the parenthesis indicate the heat reclaimed from the heat recovery ventilator.When calculating the capacity as indoor units, use the following figures:VKM50GMV1/GV1: 3.5 kW, VKM80GMV1/GV1: 5.6 kW, VKM100GMV1/GV1: 7.0 kW

2. Indoor temperature: 27°C DB, 19°C WB, Outdoor temperature: 35°C DB3. Indoor temperature: 20°C DB, Outdoor temperature: 7°C DB, 6°C WB4. Humidifying capacity is based on the following conditions:

Indoor temperature: 20°C DB, 15°C WB, Outdoor temperature: 7°C DB, 6°C WB5. The operating sound measured at the point 1.5 m below the center of the unit is

converted to that measured in an anechoic chambar built in accordance with the JIS C 1502 conditions. The actual operating sound varies depending on the surrounding conditions (near running unit’s sound, reflected sound and so on) and is normally higher than this value.For operation in a quiet room, it is required to take measures to lower the sound. For details, refer to the Engineering data.

6. The noise level at the air discharge port is about 8–11 dB or higher than the unit’s operating sound.For operation in a quiet room, it is required to take measures to lower the sound.

7. Air flow rate can be changed over to Low mode or High mode.8. In case of holding full water in humidifier.9. OA: fresh air from outdoor. RA: return air from room.

10. Specifications, design and information here are subject to change without notice.11. Power consumption and efficiency depend on the above value of air flow rate. 12. Temperature exchange efficiency is the mean value for Cooling and Heating.

Efficiency is measured under the following condition: Ratio of rated external static pressure outdoor to indoor is kept constant at 7 to 1.

Feed clean water (city water, tap water or equivalent). Dirty water may clog the valve or cause dirt deposits in the water container, resulting in poor humidifier performance. (Never use any cooling tower water and heating-purpose water.)Also, if the supply water is hard water, use a water softener because of short life.* Life of humidifying element is about 3 years (4,000 hours) under the supply water

conditions of hardness: 150 mg/l. (Life of humidifying element is about 1 year (1,500 hours) under the supply water conditions of hardness: 400 mg/l.)Annual operating hours: 10 hours/day x 26 days/month x 5 months = 1,300 hours

VKM50G(M)V1

VKM80/100G(M)V1

Dimensions

Type VKM50GMV1 VKM80GMV1 VKM100GMV1 VKM50GV1 VKM80GV1 VKM100GV1Refrigerant R410APower Supply 1 phase, 220–240 V, 50 Hz

Air Flow Rate & Static Pressure (Note 7)

Ultra-highAir flow rate (m3/h) 500 750 950Static pressure (Pa) 160 140 110

HighAir flow rate (m3/h) 500 750 950Static pressure (Pa) 120 90 70

Low

Heat exchange mode

Bypass mode

Heat exchange mode

Bypass mode

Air flow rate (m3/h) 440 640 820Static pressure (Pa) 110 70 60

560490420560490420

620560470620560470

670570480670570480

Fan Motor Type Sirroco FanMotor Output kW 0.280 × 2 0.280 × 2 0.280 × 2

Sound Level (Note 5)(220–240 V)

Ultra-high (dB) 37/37.5/3835/35.5/3632/33/34

37/37.5/3835/35.5/3632/33/34

38.5/39/4036/37/37.533/34/35.538.5/39/4036/37/37.533/34/35.5

39/39.5/4037/37.5/38

34/34.5/35.539/39.5/4037/37.5/38

34/34.5/35.5

High (dB)Low (dB)Ultra-high (dB)High (dB)Low (dB)

Humidification Capacity (Note 4) (kg/h) 2.7 4.0 5.4

Temp. Exchange Efficiency

Ultra-high (%) 76 78 74High (%) 76 78 74Low (%) 77.5 79 76.5

Enthalpy Exchange Efficiency (Cooling)

Ultra-high (%) 64 66 62High (%) 64 66 62Low (%) 67 68 66

Enthalpy Exchange Efficiency (Heating)

Ultra-high (%) 67 71 65High (%) 67 71 65Low (%) 69 73 69

Casing Galvanized Steel PlateInsulating Material Self-Extinguishable Urethane FoamHeat Exchanging System Air to Air Cross Flow Tot al Heat (Sensible + Latent Heat) ExchangeHeat Exchanger Element Specially Processed Nonflammable PaperAir Filter Multidirectional Fibrous Fleece

0°C–40°C DB, 80%RH or less-15°C–40°C DB, 80%RH or less0°C–40°C DB, 80%RH or less

s

DX-coilCapacity

Cooling (Note 2) (kW)Heating (Note 3) (kW)

DimensionsHeight (mm) 387 387 387Width (mm) 1764 1764 1764Depth (mm) 832 1214 1214

500180500150440110560490420560490420

0.280 × 238/38.5/3936/36.5/37

33.5/34.5/35.538/38.5/3936/36.5/37

33.5/34.5/35.5—7676

77.5646467676769

75017075012064080

620560470620560470

0.280 × 240/41/41.537.5/38/3934.5/36/3740/41/41.537.5/38/3934.5/36/37

—787879666668717173

95015095010082070

670570480670570480

0.280 × 240/40.5/4138/38.5/3935/36/36.540/40.5/4138/38.5/3935/36/36.5

—7474

76.5626266656569

2.83.2387

1764832

96

2.83.2

4.55.0

5.66.3

4.55.0387

17641214

109—

5.66.3387

17641214

114Machine Weight Net (kg)Gross (Note 8) (kg)

102107

120129

125134

Around UnitOA (Note 9)RA (Note 9)

Unit Ambient Condition

RXYQ5–48MY1B, RXYQ5–48MAY1, REYQ8–48MY1BConnectable outdoor units

(mm)Connection Duct Diameter ø200 ø250 ø200 ø250

Ultra-high (W)High (W)Low (W)

Power Consumption

Ultra-high (W)High (W)Low (W)

210

248

42

Supply air fan

160

250

150–

153

431

Damper plate

210

878

ø250

1688387235

60

10137

20

153 24

8

Feed water tank *1

164

130

420

160

144

832

28

102

Direct expansion coil

34

137

ø196

322

20

1764515

Exhaust air fan

94

Damper plate

ø263

1262

622

144

439

28

1214

10

235

Feed water tank *2

Exhaust air fan

89

130

210

210

1688

2020

1764

ø246

42

592

153

94

439

89

34

160

Direct expansion coil

183

Supply air fan

60

153

160387

515

250

150–

102322

Page 7: PCH0439 - Daikin | The World's No. 1 Air Conditioning …M)_Series_-_(PCH0… · Combined Air Conditioning and ... The specifications, designs, and information in this brochure are

Centralized Control of Air Conditioning and Ventilation

Cen

traliz

ed C

ontro

l of A

ir C

ondi

tioni

ng a

nd V

entil

atio

n

11

Cen

traliz

ed C

ontro

l of A

ir C

ondi

tioni

ng a

nd V

entil

atio

n

12

• Simultaneous ON/OFF of the HRV (VKM) and air conditioner• Independent operation of the HRV (VKM)• Airflow rate switching (initial setting)• Ventilation mode switching (initial setting)• Self-diagnosis functions• Filter sign display and reset• Timer settings (simultaneous control with air conditioner)• Fresh-up mode switching (Selectable: supply rich mode, exhaust

rich mode; Initial setting)

Operation of the air conditioner using the remote controller is interlocked with operation of the HRV, greatly simplifying overall system control. The same remote controller completely centralizes air conditioning and ventilation operations, so no HRV remote controller installation work is necessary. Using a centralized remote controller also frees the user to choose from a wide range of control systems that integrate air conditioning and ventilation. By incorporating a variety of centralized control equipment, the user can build a large, high-grade centralized control system.

Group ControlOne air conditioner remote controller simultaneously controls up to 16 air conditioner and HRV (VKM) units.*1: Count HRV (VKM) unit as two air conditioners. For details, see Table 1 on page 13.

Air conditioner

Up to 16 units

*1

Up to 500 m

HRV(VKM)

Air conditioner remote controller

2-Remote-Controller ControlAllows control of air conditioner and HRV units from two places by connecting two air conditioner remote controllers. (Group control possible)

Air conditioner

Up to 500 m

HRV(VKM)

Air conditioner remote controller (No. 2)

Air conditioner remote controller (No. 1)

Long-distance Remote ControlOperation control from afar, i.e., a distant control room, is possible thanks to wiring of up to 500 m. (2-remote-controller control possible)

Air conditioner

HRV(VKM)

Air conditioner remote controller

2-remote-controller control possible

Up to 500 m

A Var iety of Control Systems That Can Be Controlled Using Only the Air Conditioner Remote Controller

Operations and Control with the Air Conditioning Remote Controller

Centralized Control System

Centralized Controller (DCS302C61)• 64 groups (zones) of indoor units can be controlled individually same as LCD Remote controller.• Max.64 groups (128 indoor units controllable)• Max. 128 groups (128 indoor units) are controllable by using 2 central remote

controllers, which can control from 2 different places. • Zone control• Malfunction code display• Max. wiring length 1,000 m (Total : 2,000 m)• Combination with Unified ON/OFF controller, schedule timer and BMS system• Airflow volume and direction can be controlled individually for indoor units in

each group operation.• Ventilation volume and mode can be controlled for Heat Reclaim Ventilation

(VKM).• Up to 4 Operation/Stop pairs can be set per day by connecting a schedule timer.

By combining the (optional) centralized control equipment below, the user can achieve a wide range of comprehensive centralized control systems for air conditioning and ventilation.

Unified ON/OFF Controller (DCS301B61)• One unit can turn ON/OFF up to 16 groups (128 units) of HRV (VKM) and air

conditioner units individually or in a batch.• Lamps display operation and failure status of the connected HRV (VKM) and air

conditioner units.• Up to 8 units can be linked to allow centralized control of up to 128 units.

Schedule Timer (DST301B61)• One unit can control the operation of up to 128 HRV (VKM) and air conditioner

units on a weekly schedule.• Can set two ON/OFF operations per day for a period of one week.

Centralized controller 2 units

Number of units that can be connected per system

Unified ON/OFF controller 8 unitsSchedule timer 1 unit

IndoorUnit

Outdoor Unit

Remote Controller

HRV (VKM)

Page 8: PCH0439 - Daikin | The World's No. 1 Air Conditioning …M)_Series_-_(PCH0… · Combined Air Conditioning and ... The specifications, designs, and information in this brochure are

HRV (VKM) Control SystemsVarious Control Systems According to Applications and Conditions

Maj

or H

RV C

ontro

l Sys

tem

s

13

Maj

or H

RV C

ontro

l Sys

tem

s

14

Image of group control system

Standard system

Combined system

Independent system

System Construction

Stan

dard

Sys

tem

Air C

ondi

tioni

ng In

terlo

cked

Con

trol (

VRV,

Sky

Air)

Sys

tem

System Characteristics NecessaryAccessories

• Operation is possible using 2 remote controllers.

• Multiple HRV (VKM) units can be simultaneously controlled in batch.[Up to 8 HRV (VKM) units can be connected.]

• Independent operation of HRV (VKM) is possible.

• VRV remote controller can be used.

VRV remote controller

VRV remote controller

• Multiple VRV indoor units or HRV (VKM) units can be connected and controlled in batch, with interlocked operation of HRV (VKM)s and air conditioners by using the air conditioner remote controller.

• The HRV (VKM) unit can also be operated independently using the remote controller for the indoor unit, even if the indoor unit is not in operation.

VRV remote controller

System Construction

Air

Con

ditio

ning

Inte

rlock

ed C

entr

aliz

ed C

ontr

ol S

yste

m

Bat

ch/In

divi

dual

Con

trol

Sys

tem

Zone

Con

trol

Sys

tem

System Characteristics NecessaryAccessories

[Centralized Controller]• The centralized controller

provides setting and monitoring functions, and can control up to 128 VRV and HRV (VKM) units collectively or individually.

• Multiple groups can be controlled within the same zone.

[Unified ON/OFF Controller]• One controller can control

the “ON/OFF” operation of 16 groups of units collectively or individually.

• Up to 8 controllers can be installed in one centralized transmission line (in one system), which enables control of up to 128 groups. (16 groups x 8 = 128 groups)

[Schedule Timer]• One schedule timer can

control the weekly schedule of up to 128 units.

Unified ON/OFF controller or schedule timer, VRV remote controllerWhen necessary, centralized controller

Centralized controller, VRV remote controllerWhen necessary, unified ON/OFF controller or schedule timer

Inde

pend

ent O

pera

tion

Syst

em

Inde

pend

ent

Ope

ratio

nSi

mul

tane

ous

Ope

ratio

nof

Mul

tiple

Uni

ts

0 1 2 3 VRV Up to 16 Up to 14 Up to 12 Up to 10

4 5 6 7 8 Up to 8 Up to 6 Up to 4 Up to 2 0

Note: The HRV (VKM) uses two remote control addresses per unit, and the number of units that can be group controlled are shown above.

HRV (VKM)

Indoor unit

Indoor unit

HRV (VKM)

HRV (VKM)

ON/OFF controller or schedule timer

Air conditioner remote controller

Air conditioner remote controllerAir conditioner remote controller

Air conditioner remote controller

Indoor unitZone

1Zo

ne 2

Indoor unit

HRV (VKM)

HRV (VKM)

Centralized controller

Air conditioner remote controller

Air conditioner remote controllerAir conditioner remote controllerAir conditioner remote controller

Air conditioner remote controllerAir conditioner remote controllerAir conditioner remote controller

HRV (VKM)

Air conditioner remote controller

HRV (VKM) HRV (VKM)

Air conditioner remote controller (No. 2)

Air conditioner remote controller (No. 1)

Indoor unit HRV (VKM)

Air conditioner remote controller

Table 1 Connectable indoor units

Page 9: PCH0439 - Daikin | The World's No. 1 Air Conditioning …M)_Series_-_(PCH0… · Combined Air Conditioning and ... The specifications, designs, and information in this brochure are

Option

15 16

Installation of Optional Products (For VKM50G (M) V1, VKM80G (M) V1, VKM100G (M) V1)

For wiring

Silencer

Air suction/Discharge grilleHigh efficiency filter

Flexible duct (1 m)Flexible duct (2 m)Duct adaptor

VKM50G(M)V1 VKM80G(M)V1 VKM100G(M)V1K-DDM24B100

250 mmK-DGL200B

—K-DGL250B

200 250YAFF241G80M YAFF241G100M

Air filter for replacement YAFF242G80M YAFF241G100MK-FDS201C K-FDS251CK-FDS202B K-FDS252C

——

YDFA25A1 250

Air suction/discharge grille (Option)

Branch duct(Field supply)

SA

SA

RA

EAOA

Duct(Field supply)

Flexible duct(Option)

Silencer (Option)

Round hood(Field supply)

Thermal insulation material (Field supply)

High efficient filter(Option)

Remote Controller Centralized controller Schedule timerUnified ON/OFF controller

Flexible duct(Noise suppression type) Duct adaptorSilencer Air suction/discharge grille

(Noise suppression type)

Nominal pipe diameter (mm)White

Nominal pipe diameter (mm)

Nominal pipe diameter (mm)

Member Applicable model

Addit

ional

functi

on

Central remote controllerRemote controller

Wiring adaptor for electrical appendices

Type (indoor unit of VRV)

Installation box for adaptor PCB

Unified ON/OFF controllerSchedule timer

For humidifier running ON signal outputInstallation box for adaptor PCBFor heater control kit

BRC1A62 *1

DCS302C61DCS301B61DST301B61KRP2A61KRP50-2

KRP50-2A90 (Mounted electric component assy of HRV)BRP4A50

FXCQ-M FXKQ-MFXFQ-M FXSQ-M FXHQ-M FXAQ-M FXLQ-M FXNQ-M

FXMQ-M

KRP1B61 KRP1B59 KRP1B61—Notes 2, 3KRP1B96 —Notes 2, 3

KRP1D98Note 5KRP4A91 —

Member Applicable model

Con

trollin

g de

vice

PC B

oard

Ada

ptor

Centralized controlling device

Note: 1.2.3.4.

Installation box is necessary for each adaptor marked . Up to 2 adaptors can be fixed for each installation box.Only one installation box can be installed for each indoor unit.Up to 2 installation boxes can be installed for each indoor unit.

KRP1B3—Notes 2, 3

KRP4A93Note 3KRP1C93

FXZQ-M

Notes 4, 6KRP1B101

KRP1B61 KRP1B57

FXDQ-N

Notes 4, 6KRP1B101

KRP1B56

5.6.7.

Installation box is necessary for second adaptor.Installation box is necessary for each adaptor.*1 Necessary when operating HRV (VKM) independently. When operating interlocked

with other air conditioners, use the remote controllers of the air conditioners.

EA

OA

RA

SA

Power supply (Field supply)Relay box

Temperature thermo. (Field supply)(ON when the temperature is at or below -10°C)

HRV(VKM) Heater

control kit(Field supply)

BRP4A50

Temperature thermo. (Field supply)(OFF when the temperature is at or more than 5°C)

Indoor Outdoor

PC board adaptor for heater control kit (BRP4A50)When the installation of an electric heater is required in a cold region, this adaptor with an internal timer function eliminates the complicated timer connecting work that was necessary with conventional heaters.

Examine fully the installation place and specification for using the electric heater based on the standard and regulation of each country.Supply the electric heater and safety production devices such as a relay and a thermostat, etc., of which qualities satisfy the standerd and regulation of each country at site.Use a non-inflammable connecting duct to the electric heater. Be sure to allow 2 m or more between the electric heater and HRV (VKM) for safety.For the HRV (VKM) units, use a different power supply from that of the electric heater and install a circuit breaker for each.

Notes when installing

VKM50/80/100G(M)V1