GYPSUM BOARD
INSULATION, BATT
BOARD OR PANEL
ACOUSTIC TILE,
GLASS
PLYWOOD
C.M.U. CONCRETEBLOCK
CONCRETE CASTIN PLACE OR PRECAST
EARTH
CERAMIC TILE, QUARRY TILE
CARPET & PAD
OR RESILIENT FLOORING
(SHOW PROFILE ONLY)
WOOD FRAMING
INSULATION RIGID
INTERRUPTED MEMBER
WOOD FRAMING
THROUGH MEMBER
WOOD, FINISH
STEEL (OMIT INDIC-
ATION IN THIN MATERIAL)
MATERIAL INDICATIONS
LC
@
#
CENTER LINE
ANGLE
NUMBER
AT
WINDOW TYPE
DOOR TYPE GRID BUBBLE
ELEVATIONINTERIOR
VIEW REFERENCE
REVISION REVISION NUMBER
& AND
WINDOW NUMBER
DOOR SYMBOL
DOOR NUMBER
WINDOW SYMBOL
GRID SYMBOL
GRID NUMBER
4.
3.
2.
ALL WORK SHALL BE CONFINED TO THE DESIGNATED PROJECT LIMITS, COORDINATED WITH THE UNIVERSITY, AND ACHIEVED IN A MANOR THAT IS LEAST OBTRUSIVE TO ONGOING UNIVERSITY FUNCTION AND ACTIVITY.
THE INTENT OF THE DRAWINGS IS TO PRODUCE THE INTENDED RESULTS UNDER RECOGNIZED STANDARDS EVEN IF NOT SHOWN, BUT REASONABLY INFERABLE THEREFROM. THE CONTRACTOR SHALL CHECK ALL DRAWINGS FURNISHED TO HIM/HER UPON RECEIPT AND SHALL PROMPTLY NOTIFY THE ARCHITECTS OF ANY DISCREPANCIES. LARGER SCALE DRAWINGS TAKE PRECEDENCE OVER SMALLER SCALE DRAWINGS, AND DETAILS TAKE PRECEDENT OVER ALL. THE CONTRACTOR SHALL COMPARE ALL DRAWINGS AND VERIFY THE DETAILS BEFORE LAYING OUT THE WORK AND IMMEDIATELY CALL TO THE ATTENTION OF THE ARCHITECT ANY ERRORS DISCREPANCIES OR QUESTIONS FOUND IN THE DOCUMENTS.
ALL WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE INTERNATIONAL BUILDING CODE, 2015 EDITION AS ADOPTED BY THE STATE.
GENERAL NOTES
1.
PERFORMING ARTS CENTER (PAC) RE-ROOF
ARCHITECTURAL SYMBOLS
?
? /? ?
VIEW IDENTIFICATION
SHEET WHERE VIEW IS DRAWN
?
A
A1.01
C
BD
ELEVATION IDENTIFICATION
SHEET WHERE ELEVATION IS DRAWN
PERFORMING ARTS CENTER (PAC)TEXAS A&M UNIVERSITY CORPUS CHRISTI
NORTH
ABBREVIATIONS NOTE: NOT ALL ABBREVIATIONS ARE NECESSARILY USED.
RECEPTACLE
J
CONN CONNECTION
CONSTRUCTION
CEMENT PLASTER
DOUBLE ACTING
COUNTERSUNK
DRINKING FOUNTAIN
DOOR OPENING
EXTERIOR FINISH SYSTEM
EXPANSION JOINT
EXTERIOR FINISH
ELECTRICAL PANEL
ELECTRIC WATER
FIRE EXTINGUISHER
FIRE HOSE CABINET
FACTORY FINISH
CABINET
FOLDINGFLDG.
F.E.
FDN.
F.E.C.
F.F.EL.
F.F.
FIN.
FL.
F.H.C.
ELEVATION
FINISH
FLOOR
FOUNDATION
FIRE EXTINGUISHER
FINISH FLOOR
E.W.C.
EXPO.
EXP.
EXT.
F.A.
F.D.
F
EXIST.
EXTERIOR
FIRE ALARM
FLOOR DRAIN
COOLER
EXPOSED
EXPANSION
EXISTING
E.J.
EL.
ELEC.
ELEV.
EMER.
ENCL.
E.P.
EQ.
EQUIPT.
ENCLOSURE
EQUAL
EQUIPMENT
ELEVATION
ELECTRICAL
ELEVATOR
EMERGENCY
DWR.
DWG.
DR.
E.
E
E.F.
EA.
E.F.S.
EAST
EACH
DRAWER
DRAWING
DOOR
D
D.A.
DBL.
DET.
D.F.
DEPT.
D.
DIA.
DIM.
DISP.
DN.
D.O.
DETAIL
DOWN
DIAMETER
DIMENSION
DISPENSER
DOUBLE
DEEP / DEPTH
DEPARTMENT
C.T. CERAMIC TILE
CENTERCTR.
CTSK.
CARPET
CONTRACTOR
CORRIDOR
CONTINUOUS
C.P.
CPT.
CORR.
CONTR.
CONSTR.
CONT.
O.D. OUTSIDE DIAMETER
PLYWD.
P.T.D.
PR.
PNL.
P-LAM.
PLAS.
PLBG.
PC.
P.
PL.
PLYWOOD
PAPER TOWEL
DISPENSER
PAIR
PANEL
PLASTER
PLUMBING
PLASTIC LAMINATE
PIECE
PAINT
PLATE
OVHD
P
O.H.
OPNG.
OPP.
O.F.O.I.
OFF.
O.F.C.I.
OPENING
OPPOSITE
OVERHANG
OVERHEAD
OWNER FURNISHED
CONTRACTOR
INSTALLED
OWNER FURNISHED
OWNER INSTALLED
OFFICE
WATER RESISTANT
WEIGHT
WELDED WIRE MESH
WR.
WT.
W.W.M.
WIDTH
WITH
WOOD
WINDOW
WITHOUT
WATERPROOF
WATER CLOSET
WATER HEATER
WHERE OCCURS
W.H.
WDW.
W/O
WP.
W.O.
W.
W
W/
W.C.
WD.
N.T.S.
OA.
O.C.
OBS.
O
N.I.C.
NOM.
NO. / #
NN.
NOT TO SCALE
OVERALL
OBSCURE
ON CENTER
NOT IN CONTRACT
NOMINAL
NUMBER
NORTH
MIN.
M.O.
MTG.
MTD.
MUL.
MISC.
MFR.
M.D.
MECH.
MINIMUM
MOUNTED
MOUNTING
MISCELLANEOUS
MASONRY OPENING
MULLION
MECHANICAL
MANUFACTURER
METAL DECK
TYPICALTYP.
UNFINISHED
UNLESS OTHERWISE
URINAL
VESTIBULE
VERTICAL
VINYL COMPOSITION TILE
NOTED
V.C.T.
V
VEST.
VERT.
UUNFIN.
U.O.N.
UR.
THICK
TOILET
THRESHOLD
TONGUE AND GROOVE
TACKBOARD
DISPENSER
TELEVISION
TOILET PAPER
TOILET PAPER HOLDER
T.P.D.
T.V.
T.P.H.
THR.
T&G
THK.
TKBD.
TOIL.
LAM. LAMINATE
MAT.
MAX.
M
LT
LAV.
L.F.
MATERIAL
MAXIMUM
LAVATORY
LINEAL FEET
LIGHT
LLAB.
KIT.
K
JT.
JST.
JAN.
KITCHEN
LABORATORY
JANITOR
JOINT
JOIST
SURROUNDSURR.
SYSTEM
SUSPENDED
SYMMETRICAL
TOWEL BAR
TEMPERED
TELEPHONE
TREAD
T
T.B.
TEMP.
TEL.
T.
SUSP.
SYM.
SYS.
SQUARE
STANDARD
SPECIFICATION
SERVICE SINK
STAINLESS STEEL
STEEL
STORAGE
STRUCTURAL
S.SK.
STD.
STRUCT.
STL.
STOR.
SQ.
SPEC.
SST.
AIR CONDITIONING
ACOUSTICAL
ARCHITECTURAL
ACCESS PANEL
UNIT
CONTROL JOINT
COLUMN
CLEAN OUT
COUNTER
CONCRETE
CONDITION
COL.
COND.
CONC.
CNTR.
C.O.
CEILING
CLEAR
CAULKING
CONCRETE MASONRY
CLR.
C.M.U.
CLG.
CLKG.
CCABINETCAB.
CEMENT
CERAMICCER.
C.J.
CEM.
ARCH.
B
BLDG.
BD.
BM.
BLKG.
BOT.
BLK.
BUILDING
BEAM
BOTTOM
BLOCK
BLOCKING
BOARD
ACOUST.
A/C
A.F.F.
AL.
A.P.
ANOD.
APPROX.
ALT.
ADJ.
ALTERNATE
ALUMINUM
APPROXIMATE
ANODIZED
ABOVE FINISH FLOOR
ADJUSTABLE
A.B.
AANCHOR BOLT
PARTITION
CONCRETE
PART.
H.V.A.C.
HEATING, VENTILATION
INSUL.
INT.
I.D.
INCL.
H.W.
I
INSULATION
INSIDE DIAMETER
INCLUSIVE OR
INCLUDED
INTERIOR
& AIR CONDITIONING
HOT WATER
HORIZ.
HR.
HDWR.
H.M.
HDWD.
H.C.
H.
GYP.
H
HARDWOOD
HARDWARE
HORIZONTAL
HOLLOW METAL
HOUR
GYPSUM
HOLLOW CORE
HEIGHT/HIGH
SECTION
SHOWER
SHEET
SIMILAR
SLOPE
SANITARY NAPKIN
SANITARY NAPKIN
DISPENSER
SL.
S.N.D.
S.N.R.
SECT.
SHT.
SHWR.
SIM.
SOUTH
DISPENSER
SCHEDULE
SINGLE ACTING
SOLID CORE
SEAT COVER
SOAP DISPENSER
S.C.
S.C.D.
S.D.
SCHED.
S.A.
SS.
GND.
GR.
GL.
GA.
GALV.
G.B.
GROUND
GRADE
GLASS
GALVANIZED
GRAB BAR
GAUGE
F.S.
G
FUT.
FT.
FTG.
FURR.
F.O.S.
FR.
FPRP.
F.O.M.
F.O.F.
FINISH SYSTEM
FOOTING
FUTURE
FURRING
FOOT (OR FEET)
FACE OF FINISH
FACE OF STUD
FACE OF MASONRY
FIREPROOF(ING)
FRAME
REFRIGERATOR
REQUIRED
RESILIENT
REVISED
ROOM
ROBE HOOK
ROUGH OPENING
OR REINFORCING
REINFORCED
R.H.
RESIL.
RM.
R.O.
REFR.
REINF.
REQD.
REV.
PAPER TOWEL
RECEPTACLE
RISER
RADIUS
REFERENCE
RAD.
REF.
R.
R
P.T.R.
FLUOR.
F.O.C.
FLUORESCENT
FACE OF
REFRIGERATOR
REQUIRED
RESILIENT
REVISED
ROOM
ROBE HOOK
ROUGH OPENING
OR REINFORCING
REINFORCED
R.H.
RESIL.
RM.
R.O.
REFR.
REINF.
REQD.
REV.
RISER
RADIUS
REFERENCE
RAD.
REF.
R.
R
MTL. METAL
01
SHORING & BRACING - THE CONTRACTOR SHALL BE RESPONSIBLE FOR SHORING AND BRACING ROOFTOP EQUIPMENT, STAGED MATERIALS, AND ASSOCIATED WORK DURING THE COURSE OF CONSTRUCTION.
SHEET INDEX
ACT ACOUSTIC CEILING TILE
VICINITY MAP
1WALL/PARTITION TYPE
WALL TYPE NUMBER
WALL TYPE SYMBOL
DISCIPLINE
TEXAS A&M UNIVERSITY CORPUS CHRISTI
5. WORK SHALL BE STAGED TO FACILITATE "DRIED-IN" CONDITION AT THE COMPLETION OF EACH WORK DAY. LEAKS AND ASSOCIATED BUILDING OR INTERIOR DAMAGE CAUSED BY THE CONTRACTOR'S FAILURE TO DRY-IN THE BUILDING AT THE COMPLETION OF THE WORK DAY SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR.
DESIGN TEAM:
ARCHITECT:
CODE INFORMATION:
Project: PERFORMING ARTS CENTER RE-ROOF
Location: TEXAS A&M UNIVERSITY CORPUS CHRISTI
Applicable Regulatory Codes:
2018 International Code Council Suite 2010 DOJ ADAAG / TAS Accessibility Standards Texas Department of Insurance, Windstorm complianceFM Global Standards for CertificationOSHA Guidelines and Standards2018 NFPA 12018 NFPA 101SECO Compliance FAA Requirements
STRUCTURAL ENGINEER:freschFreeman Schroeder Architects418 Peoples Street, Suite 101Corpus Christi, Texas 78401361 - 500 - 3058
JQ Infrastructure15810 Park Ten Place, Suite 225Houston, Texas 77084832 - 941 - 5233
CONSTRUCTION DOCUMENTS
OWNER'S NORMAL FACILITY OPERATION AND ACTIVITY SCHEDULE SHALL REMAIN IN PLACE THROUGH THE DURATION OF THE PROJECT. CONTRACTOR SHALL INCORPORATE THE OWNER'S CONCERT, REHEARSAL, AND SCHEDULED CLASSES INTO THE CONSTRUCTION SCHEDULE TO INSURE POTENTIALLY DISRUPTIVE CONSTRUCTION ACTIVITIES ARE PERFORMED AT ALTERNATE TIMES.
6.
CONTRACTOR, SUB-CONTRACTORS, AND ALL WORKERS ON THE PROJECT SHALL ADHERE TO THE CONTRACTOR'S APPROVED SAFETY PROGRAM AND PROTOCOLS AT ALL TIMES. IT IS INCUMBENT UPON THE CONTRACTOR TO CONFIRM THAT THE CONTRACTOR'S SAFETY PROGRAM MEETS OR EXCEEDS ALL UNIVERSITY AND OSHA SAFETY REQUIREMENTS.
STRUCTURAL DESIGN CRITERIA:
7.
CONTRACTOR IS RESPONSIBLE FOR CONTAINING ALL DEMOLITION AND CONSTRUCTION RELATED DEBRIS WITHIN THE PROJECT LIMITS. WORK WILL BE STOPPED IF DEBRIS IS NOTED TO BE FALLING FROM THE ROOF IN AN UNCONTROLLED AND/OR UNSCHEDULED MANOR.
8.
CONTRACTOR IS RESPONSIBLE FOR COORDINATION OF DEMOLITION AND COSTRUCTION WORK AND EQUIPMENT USAGE WITH THE NAVAL AIR STATION AND FOR CONFORMING TO NAS AND FAA REQUIREMENTS AND OBTAINING APPLICABLE PERMITS.
9.
ROOF FIELD
ROOF FIELD
10
' -
0"
10' - 0"
10' - 0"
10' -
0"
10' - 0"
10
' -
0"
10' - 0"
10
' -
0"
10' - 0"
10
' -
0"
3' - 0"
3' -
0"
3' -
0"
3' - 0"
3' - 0"ROOF PERIMETER 3'-0" WIDE STRIP
ROOF CORNER - TYP.
ROOF CORNER - TYP.
ROOF PERIMETER 3'-0" WIDE STRIP
ROOF CORNER -TYP.
ROOF PERIMETER 10'-0" WIDE STRIP
CANOPY PERIMETER 10'-0" WIDE STRIP
ROOF PERIMETER 10'-0" WIDE STRIP
LINE OF BUILDING EXTERIOR WALL BELOW
CANOPY FIELD CANOPY FIELD
CANOPY PERIMETER 10'-0" WIDE STRIP
LINE OF BUILDING EXTERIOR WALL BELOW
COPYRIGHT DRAWINGS AND SPECIFICATIONS AS INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE ARCHITECT WHETHER THE PROJECT FOR WHICH THEY WERE PREPARED IS EXECUTED OR NOT. THEY ARE NOT TO BE USED BY THE OWNER ON OTHER PROJECTS OR EXTENSIONS TO THE ORIGINAL PROJECT EXCEPT BY AGREEMENT WITH AND APPROPRIATE COMPENSATION TO THE ARCHITECT. TEXAS BOARD OF ARCHITECTURAL EXAMINERS, (512) 305-9000 / WWW.TBAE.STATE.TX.US, HAS JURISDICTION OVER INDIVIDUALS LICENSED UNDER THE ARCHITECTS REGISTRATION LAW. TEXAS CIVIL STATUTES, ARTICLE 249A.
REVISIONS:
DATE:
ww
w.f
rescharc
h.c
om
418 P
eople
s S
t, S
te.
101
Corp
us C
hristi,
TX
78418
(361)
960 -
3771
(
361)
500 -
3058
TIT
LE
SH
EE
T A
ND
GE
NE
RA
L N
OT
ES
PE
RF
OR
MIN
G A
RT
S C
EN
TE
R R
E-R
OO
F
TE
XA
S A
&M
UN
IVE
RS
ITY
CO
RP
US
CH
RIS
TI
G0.01
9/7/2018
9/7/2018
SHEET INDEX
SheetNumber Sheet Name
GENERAL
G0.01 TITLE SHEET AND GENERAL NOTES
ARCHITECTURE
A0.01 ROOF DEMOLITION PLAN
A1.01 ROOF PLAN
A3.01 DETAILS
A3.02 DETAILS
A3.03 DETAILS
0' 10' 20' 40'
1" = 20'-0"G0.01
A ROOF UPLIFT ZONE DIAGRAM
4"VTR
4"VTR
2"VTR
2"VTR
4"VTR
SLOPE DN.
SLOPE DN.
SLOPE DOWN 2"SLOPE DOWN 2"
SLOPE DOWN
SLOPE DN.
SLOPE DOWN
SLOPE DOWN
SLOPE DN.
SLOPE DOWN
SLOPE DN.
SLOPE DOWN
SLOPE DOWN
SLOPE DN.
SLOPE DOWN
SLOPE DOWN
SLOPE DOWN
SLOPE DOWN
SLOPE DOWN
SLOPE DOWN
TYP.
02-001 02-00202-002
02-002
02-002
02-002
02-003a
02-003a
02-003a
02-003a
02-003a
02-003a
02-003a
02-003b
02-004
02-004
02-004
02-004 02-004
02-004
02-004
02-005
02-005
02-005
02-006 02-004
02-008
02-009
02-009
02-009
02-00902-010
02-010
02-010 02-010
02-010
02-010
02-010
02-010
02-010
02-010
02-007
02-007
02-007
02-007
02-007 02-007
02-003b
02-003b
02-003a
CO
NC
RE
TE
R
OO
F D
EC
KM
ET
AL
RO
OF
DE
CK
FLAT
VALLEY
VALLEY
VA
LLE
Y
RIDGE
50'-11"
51'-5"
51'-5" 51'-5"
50'-0"
51'-5"
50'-0"
FLAT
50'-0"
50'-0"
50'-0"
50'-0"
51'-5"
51'-5"
APPROXIMATE CONFIGURATION OF EXISTING STRUCTURAL ROOF DECK SLOPES. AREAS OF EXISTING TAPERED INSULATION OVER THE STRUCTURAL ROOF DECK ACHIEVES THE EXISTING ROOF SLOPES DEPICTED IN THE ROOF DEMOLITION PLAN. SEE RECORD DRAWINGS FOR ADDITIONAL INFORMATION REGARDING EXISTING ROOF DECK SLOPES AND CONDITIONS.
02-001 APPROXIMATE AREA OF FASCIA DAMAGE - REMOVE DAMAGED PANELS AND PREP FOR REPAIR
APPROXIMATE AREA OF CORRODED FASCIA FASTENERS - REMOVE ALL CORRODED NON-SST. FASTENERS AND PREP FOR REPLACEMENT
REMOVE EXISTING MODIFIED BITUMEN ROOFING SYSTEM INCLUDING ROOF MEMBRANE, COVERBOARD, AND INSULATION DOWN TO CONCRETE ROOF DECK - WORK SHALL BE STAGED TO ENSURE DRY CONDITIONS / SEALED ENVOLOPE AT THE CONCLUSION OF EACH DAY OF WORK - TYPICAL
REMOVE EXISTING MODIFIED BITUMEN ROOFING SYSTEM INCLUDING ROOF MEMBRANE, COVERBOARD, AND INSULATION DOWN TO METAL ROOF DECK - WORK SHALL BE STAGED TO ENSURE DRY CONDITIONS / SEALED ENVOLOPE AT THE CONCLUSION OF EACH DAY OF WORK - TYPICAL
REMOVE EXISTING SHEET METAL EDGE METAL FLASHING INCLUDING CLEATS, FASTENERS, AND ASSOCIATED BLOCKING AS REQUIRED
REMOVE EXISTING SHEET METAL PARAPET CAP FLASHING INCLUDING SHIMS, CLEATS, FASTENERS, AND ASSOCIATED BLOCKING AS REQUIRED
REMOVING EXISTING EXPANSION JOINT ASSEMBLY INCLUDING FLASHINGS CURBS AND BLOCKING
REMOVE EXISTING STRAINER BASKET, CLAMP RING AND BOLTS. EVALUATE EXISTING DRAIN BODY AND REMOVE AS REQUIRED
REMOVE EXISTING ROOF HATCH AND ASSOCIATED FLASHINGS, CURBS, AND BLOCKING AS REQUIRED.
REMOVE EXISTING MECHANICAL EQUIPMENT INCLUDING GUY WIRES, ELECTRICAL CONDUIT, DISCONNECTS, FLASHINGS, CURBS, AND BLOCKING AS REQUIRED. STORE MECHANICAL EQUIPMENT AND ASSOCIATED COMPONENTS FOR REINSTALLATION
REMOVE EXISTING LIGHTNING PROTECTION SYSTEM AND ASSOCIATED COMPONENTS AND STORE FOR REINSTALLATION WHERE APPLICABLE
ROOF DEMOLITION PLAN KEY NOTES
02-002
02-003a
02-004
02-005
02-006
02-007
02-008
02-009
02-010
02-003b
NO
RT
H
COPYRIGHT DRAWINGS AND SPECIFICATIONS AS INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE ARCHITECT WHETHER THE PROJECT FOR WHICH THEY WERE PREPARED IS EXECUTED OR NOT. THEY ARE NOT TO BE USED BY THE OWNER ON OTHER PROJECTS OR EXTENSIONS TO THE ORIGINAL PROJECT EXCEPT BY AGREEMENT WITH AND APPROPRIATE COMPENSATION TO THE ARCHITECT. TEXAS BOARD OF ARCHITECTURAL EXAMINERS, (512) 305-9000 / WWW.TBAE.STATE.TX.US, HAS JURISDICTION OVER INDIVIDUALS LICENSED UNDER THE ARCHITECTS REGISTRATION LAW. TEXAS CIVIL STATUTES, ARTICLE 249A.
REVISIONS:
DATE:
ww
w.f
rescharc
h.c
om
418 P
eople
s S
t, S
te.
101
Corp
us C
hristi,
TX
78418
(361)
960 -
3771
(
361)
500 -
3058
RO
OF
DE
MO
LIT
ION
PLA
N
PE
RF
OR
MIN
G A
RT
S C
EN
TE
R R
E-R
OO
F
TE
XA
S A
&M
UN
IVE
RS
ITY
CO
RP
US
CH
RIS
TI
A0.01
9/7/2018
9/7/2018
0' 4' 8' 16'
1/8" = 1'-0"A0.01
1 ROOF DEMOLITION PLAN
1). SEE GENERAL NOTES SHEET G0.01 FOR ADDITIONAL INFORMATION
2). SLOPES INDICATED ARE APPROXIMATE EXISTING ROOF SURFACE SLOPES. SLOPES ARE ACHIEVED BY THE USE OF TAPERED INSULATION OVER A SLOPED STRUCTURAL ROOF DECK. SEE 2/A1.01 FOR APPROXIMATE STRUCTURAL ROOF DECK SLOPES. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS.
3). ADDITIVE ALTERNATE No.1 AND ADDITIVE ALTERNATE No.2 INCLUDE ASSOCIATED DEMOLITION OF EXISTING METAL FASCIA PANEL AT THE FULL BUILDING PERIMETER - SEE SHEET A1.01 FOR ADDITIONAL INFORMATION.
1" = 30'-0"A0.01
A STRUCTURAL ROOF DECK SLOPE DIAGRAM
SHEET NOTES:
NOT TO SCALE
SLO
PE
DO
WN
SLO
PE
DO
WN
SLO
PE
DO
WN
SLO
PE
DO
WN
SLO
PE
DO
WN
SLO
PE
DO
WN
SLO
PE
DO
WN
SLO
PE
DO
WN
SLO
PE
DO
WN
SLO
PE
DO
WN
SLO
PE
DO
WN
SLO
PE
DO
WN
SLO
PE
DO
WN
SLO
PE
DO
WN
SLO
PE
DO
WN
SLO
PE
DO
WN SLO
PE
DO
WN
SLO
PE
DO
WN
SLO
PE
DO
WN
SLO
PE
DO
WN
SLO
PE
DO
WN
2
A3.01
2
A3.01
2
A3.01
1
A3.01
1
A3.01
1
A3.01
1
A3.01
1
A3.01
1
A3.01
1
A3.01
3
A3.01
3
A3.01
3
A3.01
3
A3.01
3
A3.01
3
A3.01
4
A3.01
5
A3.01
5
A3.01
5
A3.01
5
A3.01
SIM.
SIM.
SIM.
5
A3.01
8
A3.01TYP.
8
A3.01TYP.
8
A3.01 TYP.
8
A3.01SIM.TYP.
8
A3.01
8
A3.01
8
A3.01 TYP.
TYP.
TYP.
1
A3.02 SIM.TYP.
1
A3.02SIM.TYP.
1
A3.02SIM.TYP.
1
A3.02 SIM.TYP.
1
A3.02 SIM.TYP.
2
A3.02
2
A3.03
3
A3.03TYP.
3
A3.03 TYP.
3
A3.03TYP.
A3.03
1A3.03
1
07-001 07-00207-002
07-002
07-002
07-002
07-003a
07-003a
07-003a
07-003a
07-003a
07-003a
07-003a
07-003b
07-004
07-004
07-004
07-004 07-004
07-004
07-004
07-005
07-005
07-005
07-006 07-004
1
A3.01SIM.
07-011
07-008
07-011
07-011
07-011
07-009
07-009
07-009
07-00907-010
07-010
07-010 07-010
07-010
07-010
07-010
07-010
07-010
07-010
07-007
07-007
07-007
07-007
07-007
07-007
07-007
SLOPE VALLEY DOWN 2%
SLOPE VALLEY DOWN 2%
SLOPE VALLEY DOWN 2%
SLOPE VALLEY DOWN 2%
07-003b
07-003a
07-002
MECHANICAL VENT OR FAN WITH ASSOCIATED CURB
PIPE VENT OR PIPE SUPPORT WITH ASSOCIATED FLASHING
AREA OF TAPERED INSULATION TO ACHIEVE DESIRED SLOPE OR CRICKET
ROOF PLAN LEGEND
LIGHTNING PROTECTION SYSTEM COMPONENT
DRAIN SCUPPER / OVERFLOW SCUPPER
SLOPE ARROW (SLOPE DOWN AT 1/4" = 1'-0" MINIMUM)
ACCESS HATCH
APPROXIMATE AREA OF EXISTING FASCIA FASTENERS TO BE REPLACED
APPROXIMATE AREA OF DAMAGED FASCIA TO BE REPAIRED/REPLACED
07-001 APPROXIMATE AREA OF FASCIA DAMAGE - REPAIR FORMED METAL WALL PANEL FASCIA PER DETAIL 1/A3.01
APPROXIMATE AREA OF CORRODED FASCIA FASTENERS - REPLACE WHERE OCCUR PER DETAIL 1/A3.01
SBS MODIFIED BITUMEN ROOFING SYSTEM OVER EXISTING CONCRETE COMPOSITE ROOF DECK - SEE SPECIFICATION SECTION 07 5216.1.
SBS MODIFIED BITUMEN ROOFING SYSTEM OVER EXISTING METAL ROOF DECK - SEE SPECIFICATION SECTION 07 5216.2.
316L / No.3 FINISH SST. SHEET METAL EDGE METAL FLASHING FINISH - SEE DETAILS 1/A3.01, 2/A3.01, AND 7/A3.01 - TYPICAL
316L / No.3 FINISH SST. SHEET METAL PARAPET CAP FLASHING
EXPANSION JOINT / EXPANSION JOINT COVER
ROOF DRAIN CLAMP RING, BOLTS, AND SST. STRAINER BASKET. EVALUATE DRAIN BODY AND REPLACE AS REQUIRED.
ROOF HATCH OVER EXISTING OPENING - CONFIRM OPENING SIZE AND CONFIGURATION
REINSTALL EXISTING MECHANICAL EQUIPMENT INCLUDING GUY WIRES AND ELECTRICAL CONDUIT CONNECTIONS - TYPICAL - SEE DETAILS 1/A3.02 AND 3/A3.02
REINSTALL, TEST, AND RECERTIFY EXISTING LIGHTNING PROTECTION SYSTEM - REPLACE COMPONENTS AS REQUIRED - TYPICAL
AREA OF TAPERED INSULATION TO ACHIEVE INDICATED SLOPE
ROOF PLAN KEY NOTES
07-002
07-003a
07-004
07-005
07-006
07-007
07-008
07-009
07-010
07-011
07-003b
NO
RT
H
COPYRIGHT DRAWINGS AND SPECIFICATIONS AS INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE ARCHITECT WHETHER THE PROJECT FOR WHICH THEY WERE PREPARED IS EXECUTED OR NOT. THEY ARE NOT TO BE USED BY THE OWNER ON OTHER PROJECTS OR EXTENSIONS TO THE ORIGINAL PROJECT EXCEPT BY AGREEMENT WITH AND APPROPRIATE COMPENSATION TO THE ARCHITECT. TEXAS BOARD OF ARCHITECTURAL EXAMINERS, (512) 305-9000 / WWW.TBAE.STATE.TX.US, HAS JURISDICTION OVER INDIVIDUALS LICENSED UNDER THE ARCHITECTS REGISTRATION LAW. TEXAS CIVIL STATUTES, ARTICLE 249A.
REVISIONS:
DATE:
ww
w.f
rescharc
h.c
om
418 P
eople
s S
t, S
te.
101
Corp
us C
hristi,
TX
78418
(361)
960 -
3771
(
361)
500 -
3058
RO
OF
PLA
N
PE
RF
OR
MIN
G A
RT
S C
EN
TE
R R
E-R
OO
F
TE
XA
S A
&M
UN
IVE
RS
ITY
CO
RP
US
CH
RIS
TI
A1.01
9/7/2018
9/7/2018
0' 4' 8' 16'
1/8" = 1'-0"A1.01
1 ROOF PLAN
ALTERNATES
ADDITIVE ALTERNATE No. 1: PROVIDE CONTINUOUS BUILDING PERIMETER DEBRIS BARRIER FOR DURATION OF PROJECT. CONTRACTOR TO PROPOSE, PROVIDE, AND INSTALL NETTING OR SIMILAR DEBRIS BARRIER SOLUTION TO BE NO LESS THAN 4'-0" HIGH AROUND THE FULL BUILDING PERIMETER. SOLUTION MUST INCLUDE STRATEGY FOR WORKING AROUND THE NETTING AND SUPPORTS AT PERIMETER CONDITIONS AND REMOVAL OF BARRIER ANDASSOCIATED SUPPORTS UPON COMPLETION OF THE PROJECT INCLUDING TOUCH-UP AND REPAIR OF ANY AFFECTED AREAS.
ADDITIVE ALTERNATE No. 2: REPLACE EXISTING ALUMINUM FASCIA PANELING IN PLANE WITH MISSING PANELING (REFER TO KEYNOTE 07-001) AROUND THE ENTIRE BUILDING PERIMETER WITH 316L/No.3 FINISH STAINLESS STEEL PANEL PER DETAIL 6/A3.01.
ADDITIVE ALTERNATE No. 3: REPLACE EXISTING ALUMINUM UPPER FASCIA/ SOFFIT TRIM PANEL AROUND THE ENTIRE BUILDING PERIMETER WITH 316L/No.3 FINISH STAINLESS STEEL PANEL PER DETAIL 6/A3.01.
TREATED BLOCKING AS REQUIRED
316L / No.3 FINISH SST. CONTINUOUS DRIP EDGE FLASHING AND CLEAT
SBS MODIFIED ROOFING SYSTEM
PROTECTION/COVER BOARD
RIGID INSULATION
REPLACE AREA OF TEXTURED ALUMINUM SHEET METAL AS INDICATED IN PLANS. MATCH EXISTING GAUGE, TEXTURE, AND FINISH
STAINLESS STEEL FASTENERS WITH STAINLESS STEEL NEOPRENE WASHERS. COORDINATE FASTENER LOCATION WITH STRUCTURAL MEMBERS - TYP.
NOTE: IN AREAS OF EXISTING FASCIA PANEL, REPLACE EXISTING CORRODED FASTENERS WITH STAINLESS STEEL FASTENERS WITH STAINLESS STEEL NEOPRENE WASHERS. SEE PLANS FOR LOCATION AND ADDITIONAL INFORMATION
SEE PLANS FOR LOCATION OF
FASCIA AND FASTENER REPAIR
EXISTING STRUCTURE
REPAIR EXISTING AIR BARRIER AS REQUIRED
EXISTING SHEATHING
EXISTING TEXTURED ALUMINUM SHEET METAL OVER EXISTING AIR BARRIER OVER EXISTING SHEATHING -TYPICAL
6"
TREATED BLOCKING AS REQUIRED
316L / No.3 FINISH SST. CONTINUOUS DRIP EDGE FLASHING AND CLEAT
SBS MODIFIED ROOFING SYSTEM
PROTECTION/COVER BOARD
TAPERED RIGID INSULATION - SEE PLANS FOR CONFIGURATION
EXISTING STRUCTURE
EXISTING TEXTURED ALUMINUM SHEET METAL OVER EXISTING AIR BARRIER OVER EXISTING SHEATHING - TYPICAL
SBS MODIFIED ROOFING SYSTEM
PROTECTION/COVER BOARD
RIGID INSULATION
EXISTING ROOF DECK AND CONCRETE FILL
SBS MODIFIED FLASHING MEMBRANE
ROOFING SYSTEM COMPATIBLE SEALANT
PRIME FLANGE - TYPICAL
SST UMBRELLA FLASHING WITH SST DRAWBAND
SEALANT
EXISTING FIRE DEPARTMENT CONNECTION ASSEMBLY -VERIFY CONFIGURATION
SHEET METAL PIPE SLEEVE, SOLDER SEAMS
NEW STAINLESS STEEL STRAINER
FIELD VERIFY
VARIES
NEW MODIFIED SBS ROOFING SYSTEM -TYPICAL
PROTECTION / COVER BOARD AND RIGID INSULATION- TYP.
NEW CLAMP RING AND BOLTS
EXISTING ROOF DRAIN BODY
EXISTING METAL DECK AND CONCRETE TOPPING
EXISTING DRAIN LINE -VERIFY SIZE
REPLACE DRAIN BODY AS REQUIRED
LEAD SHEET FLASHING
SBS FLASHING MEMBRANE
PROVIDE UNIT PRICE:STAINLESS STEEL ROOF DRAIN REPLACEMTNE FLASHING INSERT; ZURN RD 2150 OR SIMILAR
PRIME FLANGE AND SET IN COMPATIBLE ROOF CEMENT
SBS FLASHING MEMBRANE
SBS MODIFIED ROOFING SYSTEM
PROTECTION/COVER BOARD
RIGID INSULATION
EXISTING ROOF DECK AND CONCRETE FILL
SBS MODIFIED FLASHING MEMBRANE
ROOFING SYSTEM COMPATIBLE SEALANT
PRIME FLANGE - TYPICAL
FLEXIBLE METAL PIPE BOOT WITH INTEGRAL FLANGE
EXISTING VENT STACK
TYP.
6"
SBS MODIFIED ROOFING SYSTEM
PROTECTION/COVER BOARD
RIGID INSULATION
EXISTING ROOF DECK AND CONCRETE FILL
SBS MODIFIED FLASHING MEMBRANE
ROOFING SYSTEM COMPATIBLE SEALANT
PRIME FLANGE - TYPICAL
FLEXIBLE METAL PIPE BOOT WITH INTEGRAL FLANGE
LIGHTNING PROTECTION SYSTEM CONDUCTOR AND FLASHING CAP
TYP.
6"
MIN.
6"
SBS MODIFIED ROOFING SYSTEM
316L / No.3 FINISH SST. EDGE METAL FLASHING - TYPICAL
MINIMUM 6" WIDE COVER CAP AT JOINTS - SET IN SEALANT - TYPICAL
FLASHING JOINT
ADDITIVE ALTERNATE No. 2: REPLACE ALUMINUM FASCIA PANEL WITH 316L / No.3 FINISH STAINLESS STEEL FASICA PANEL AT ENTIRE BUILDING PERIMETER - FORMED TO MATCH EXISTING PROFILE.
STAINLESS STEEL FASTENERS WITH STAINLESS STEEL NEOPRENE WASHERS. COORDINATE FASTENER LOCATION WITH STRUCTURAL MEMBERS - TYP.
FLUID APPLIED TYVEK AIR BARRIER OR APPROVED EQUAL
EXISTING SHEATHING
SEE 1/A3.01 FOR ADDITIONAL NOTES
ADDITIVE ALTERNATE No. 3: REPLACE UPPER ALUMINUM FASCIA /SOFFIT PANEL WITH 316L / No.3 FINISH STAINLESS STEEL FASICA PANEL AT ENTIRE BUILDING PERIMETER
COPYRIGHT DRAWINGS AND SPECIFICATIONS AS INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE ARCHITECT WHETHER THE PROJECT FOR WHICH THEY WERE PREPARED IS EXECUTED OR NOT. THEY ARE NOT TO BE USED BY THE OWNER ON OTHER PROJECTS OR EXTENSIONS TO THE ORIGINAL PROJECT EXCEPT BY AGREEMENT WITH AND APPROPRIATE COMPENSATION TO THE ARCHITECT. TEXAS BOARD OF ARCHITECTURAL EXAMINERS, (512) 305-9000 / WWW.TBAE.STATE.TX.US, HAS JURISDICTION OVER INDIVIDUALS LICENSED UNDER THE ARCHITECTS REGISTRATION LAW. TEXAS CIVIL STATUTES, ARTICLE 249A.
REVISIONS:
DATE:
ww
w.f
rescharc
h.c
om
418 P
eople
s S
t, S
te.
101
Corp
us C
hristi,
TX
78418
(361)
960 -
3771
(
361)
500 -
3058
DE
TA
ILS
PE
RF
OR
MIN
G A
RT
S C
EN
TE
R R
E-R
OO
F
TE
XA
S A
&M
UN
IVE
RS
ITY
CO
RP
US
CH
RIS
TI
A3.01
9/7/2018
9/7/2018
3" 6"0' 12"
3" = 1'-0"A3.01
1 ROOF EDGE CONDITION
3" 6"0' 12"
3" = 1'-0"A3.01
2 ROOF TAPERED EDGE CONDITION
3" 6"0' 12"
3" = 1'-0"A3.01
4 FIRE CONNECTION FLASHING
3" 6"0' 12"
3" = 1'-0"A3.01
3 ROOF DRAIN
3" 6"0' 12"
3" = 1'-0"A3.01
5 ROOF PIPE PENNETRATION - VTR
3" 6"0' 12"
3" = 1'-0"A3.01
8 LIGHTNING PROTECTION PENETRATION
3" 6"0' 12"
3" = 1'-0"A3.01
7 ROOF EDGE TYP. FLASHING JOINTS
NOTE: SIMILAR AT METAL DECK
NOTE: SIMILAR AT METAL DECK
NOTE: SIMILAR AT METAL DECK SEE A3.03 FOR TYPICAL DETAILS AT METAL DECK
3" 6"0' 12"
3" = 1'-0"A3.01
6 ROOF EDGE CONDITION ALTERNATES
SLAM LATCH WITH HASP
THERMALLY BROKEN COVER WITH EPDM GASKET
AUTOMATIC HOLDOPEN ARM
THERMALLY BROKEN CURB WITH CAP FLASHING
BLOCKING AS REQUIRED
8"
MIN
.
WHERE 3" OVERLAP IS NOT ACHIEVABLE WITH EXISTING EQUIPMENT, ADD 316L / No.3 FINISH SST. COUNTERFLASHING
316L / No3 FINISH SST. COUNTERFLASHING WHERE REQ.
EXISTING ROOFTOP EQUIPMENT (REMOVE AND RE-INSTALL). SIZE AND TYPE VARIES - FIELD VERIFY ALL
REMOVE AND REINSTALL EXISTING ROOFTOP EQUIPMENT CAP AND FLASHING ASSEMBLY -REPAIR OR REPLACE AS REQUIRED
CONTINUOUS SEALANT OR GASKET SEAL - TYPICAL
TREATED BLOCKING AS REQUIRED
FIBER CANT STRIP
SBS MODIFIED ROOFING SYSTEM
EXISTING ROOF DECK AND TOPPING
EXISTING STRUCTURE
PROTECTION/COVER BOARD
RIGID INSULATION
8"
MIN
.
3"
MIN
.
3"
MIN
.
MIN
.
4"
SBS MODIFIED ROOFING SYSTEM
PROTECTION/COVER BOARD
RIGID INSULATION
EXISTING ROOF DECK AND CONCRETE FILL
SBS MODIFIED FLASHING MEMBRANE
ROOFING SYSTEM COMPATIBLE SEALANT
PRIME FLANGE - TYPICAL
EQUIPMENT GUY WIRE ANCHOR, CONDUIT PENETRATION, OR OTHER
6"
PROVIDE SST. UMBRELLA FLASHING WITH SST DRAW BAND AND SEALANT WHERE ASSEMBLY ALLOWS
NON-SHRINK GROUT
POURABLE SEALANT WITH SLOPED TOP
NOTE: UTILIZE ROOF PENETRATION POCKET DETAILS ONLY WHEN OTHER APPLICABLE DETAILS ARE NOT ACHIEVABLE
COPYRIGHT DRAWINGS AND SPECIFICATIONS AS INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE ARCHITECT WHETHER THE PROJECT FOR WHICH THEY WERE PREPARED IS EXECUTED OR NOT. THEY ARE NOT TO BE USED BY THE OWNER ON OTHER PROJECTS OR EXTENSIONS TO THE ORIGINAL PROJECT EXCEPT BY AGREEMENT WITH AND APPROPRIATE COMPENSATION TO THE ARCHITECT. TEXAS BOARD OF ARCHITECTURAL EXAMINERS, (512) 305-9000 / WWW.TBAE.STATE.TX.US, HAS JURISDICTION OVER INDIVIDUALS LICENSED UNDER THE ARCHITECTS REGISTRATION LAW. TEXAS CIVIL STATUTES, ARTICLE 249A.
REVISIONS:
DATE:
ww
w.f
rescharc
h.c
om
418 P
eople
s S
t, S
te.
101
Corp
us C
hristi,
TX
78418
(361)
960 -
3771
(
361)
500 -
3058
DE
TA
ILS
PE
RF
OR
MIN
G A
RT
S C
EN
TE
R R
E-R
OO
F
TE
XA
S A
&M
UN
IVE
RS
ITY
CO
RP
US
CH
RIS
TI
A3.02
9/7/2018
9/7/2018
6" 12"0'
1 1/2" = 1'-0"A3.02
2 ROOF HATCH
3" 6"0' 12"
3" = 1'-0"A3.02
1 ROOF EQUIPMENT FLASHING
NOTE: SIMILAR AT METAL DECK
SEE A3.03 FOR TYPICAL DETAILS AT METAL DECK
3" 6"0' 12"
3" = 1'-0"A3.02
3 ROOF PENNETRATION
NOTE: SIMILAR AT METAL DECK
3"
3"
3"
1"
3" MIN.
3" MIN.
6"
2"
3" MIN.
6"
3"
3"
4" MIN.
DRAIN SUPPER / OVERFLOW SCUPPER DETAIL NOTES:
1). AXONOMETRIC DETAILS ARE DIAGRAMMATIC. FIELD VERIFY ALL CONDITIONS PRIOR TO THE PRODUCTION AND SUBMITTAL OF SHEET METAL SHOP DRAWINGS.
2). ALL SHEET METAL WORK TO BE 316S STAINLESS STEEL WITH No.2 FINISH.
3). ALL OVERLAPS SHOWN AND/OR DIMENSIONED ARE MINIMUMS.
4). SHEET METAL WORK TO CONFORM TO SMACNA GUIDELINES.
CUT INTO EXISTING GROUT JOINT TO ALLOW FLASHING INSERTION
EXISTING MASONRY WALL
DRAIN SCUPPER OVERFLOW SCUPPER
EXISTING MASONRY WALL
SALVAGE AND REUSE STAINLESS STEEL DOWNSPOUT OR REPLACE AS REQUIRED.
316L / No.3 FINISH STAINLESS STEEL CONDUCTOR HEAD - SHOP FABRICATED WITH ALL SEAMS WELDED.
EXISTING ROOF STRUCTURE AND ROOF DECK
MODIFIED SBS ROOFING SYSTEM
RIGID INSULATION AND COVERBOARD
316L / No.3 FINISH SST. FLASHING HOOD - SEAL ENDS
MODIFIED SBS ROOFING SYSTEM FLASHING MEMBRANE
CONTINUOUS SEALANT - TYPICAL
PROVIDE CONDUCTOR HEAD OVERFLOW
STRAP AS REQ. TO STRENGTHEN BOX ASSEMBLY
CUT CONDUCTOR HEAD BOX BACK TO ALLOW FOR FLASHING HOOD
316L / No.3 FINISH SST. SCUPPER AND TRIM ASSEMBLY
MODIFIED SBS ROOFING SYSTEM
RIGID INSULATION AND COVERBOARD
316L / No.3 FINISH SST. SCUPPER AND TRIM ASSEMBLY
MINERAL FIBER CANT
TREATED BLOCKING
EXISTING ROOF STRUCTURE
EXISTING ROOF DECK
CONTINUOUS SEALANT - TYPICAL
CONTINUOUS SEALANT - TYPICAL
MODIFIED SBS ROOFING SYSTEM FLASHING MEMBRANE
THERMAL BARRIER AND NAILBOARD
THERMAL BARRIER AND NAILBOARD
SBS FLASHING MEMBRANE
TREATED BLOCKING
SBS MODIFIED ROOFING SYSTEM OVER EXISTING METAL DECK
PROTECTION/COVER BOARD
RIGID INSULATION
EXISTING STRUCTURE
EXPANSION JOINT ASSEMBLY AND CONTINUOUS COVER PLATE
6" MIN COVERPLATE AT JOINTS
FACTORY FABRICATE CORNERS
FIBER CANT STRIP
FACTORY FABRICATE END CAP
SBS MODIFIED ROOFING SYSTEM OVER EXISTING CONCRETE FILL DECK
THERMAL BARRIER
NAILBOARD
SBS FLASHING MEMBRANE
TREATED BLOCKING
FIBER CANT STRIP
SBS MODIFIED ROOFING SYSTEM
PROTECTION/COVER BOARD
RIGID INSULATION
6"4"
AT CORNERS
1' - 0" MIN. TYP.
MIN. TYP.
6"
PLAN VIEW
316L / No.3 FINISH SST. PARAPET CAP FLASHING AND CLEATS
FACTORY FABRICATED, WELDED CORNER
SEAM COVER IN FULL BED OF SEALANT - TYP.
EXISTING STRUCTURE
EXISTING MASONRY WALL
5/8" EXTERIOR GYPSUM SHEATHING
THERMAL BARRIER
NAILBOARD
FLASHING MEMBRANE
COPYRIGHT DRAWINGS AND SPECIFICATIONS AS INSTRUMENTS OF SERVICE ARE THE PROPERTY OF THE ARCHITECT WHETHER THE PROJECT FOR WHICH THEY WERE PREPARED IS EXECUTED OR NOT. THEY ARE NOT TO BE USED BY THE OWNER ON OTHER PROJECTS OR EXTENSIONS TO THE ORIGINAL PROJECT EXCEPT BY AGREEMENT WITH AND APPROPRIATE COMPENSATION TO THE ARCHITECT. TEXAS BOARD OF ARCHITECTURAL EXAMINERS, (512) 305-9000 / WWW.TBAE.STATE.TX.US, HAS JURISDICTION OVER INDIVIDUALS LICENSED UNDER THE ARCHITECTS REGISTRATION LAW. TEXAS CIVIL STATUTES, ARTICLE 249A.
REVISIONS:
DATE:
ww
w.f
rescharc
h.c
om
418 P
eople
s S
t, S
te.
101
Corp
us C
hristi,
TX
78418
(361)
960 -
3771
(
361)
500 -
3058
DE
TA
ILS
PE
RF
OR
MIN
G A
RT
S C
EN
TE
R R
E-R
OO
F
TE
XA
S A
&M
UN
IVE
RS
ITY
CO
RP
US
CH
RIS
TI
A3.03
9/7/2018
9/7/2018
3" = 1'-0"A3.03
1 ROOF SCUPPER DETAILS
3" 6"0' 12"
3" = 1'-0"A3.03
2 ROOF EXPANSION JOINT COVER
3" 6"0' 12"
3" = 1'-0"A3.03
3 ROOF PARAPET CAP FLASHINGN. T. S.
SEE A3.01 AND A3.02 FOR TYPICAL DETAILS AT CONCRETE DECK