Page 1: Permeate Concentrate HT SERIES - Puroserve · Puroserve HT Series Reverse Osmosis System Operator’s Guide 6925 Canoga Avenue, Canoga Park, CA 91303 (800) 594-3300 Page 10 PLUMBING

City PSI Pump PSI

ConcentrateAdjustment

Permeate Concentrate

HT SERIES

��

HT600Operation Manual

FOR ILLUSTRATION PURPOSES ONLY

Page 2: Permeate Concentrate HT SERIES - Puroserve · Puroserve HT Series Reverse Osmosis System Operator’s Guide 6925 Canoga Avenue, Canoga Park, CA 91303 (800) 594-3300 Page 10 PLUMBING

Puroserve HT Series Reverse Osmosis System Operator’s Guide

6925 Canoga Avenue, Canoga Park, CA 91303www.Puroserve.com (800) 594-3300 Page 2

TABLE OF CONTENTS

UNIT SPECIFICATIONS 3

OPERATING DO’S AND DONT’S 4

UNIT AUTOMATION 4

UNIT SHUT-DOWN 4

UNIT MONITORING, MAINTENANCE RECORD KEEPING 4

HT 600 OVERVIEW 5

GENERAL INFORMATION AND SAFETY 6

SYSTEM INSTALLATION 6

PRODUCT WATER STORAGE TANK FLOAT TREE INSTALLATION 7

PLUMBING 9-10

PLUMBING LAYOUT 8

INITIAL SYSTEM STARTUP 11

SERVICE MAINTENANCE PROCEDURES 12-13

HT SERIES ELECTRICAL DIAGRAM 14

OZONE GENERATOR 13

TROUBLESHOOTING 15

TANK DIMENSIONS 16

PUROSERVE LIMITED WARRANTY 17

Page 3: Permeate Concentrate HT SERIES - Puroserve · Puroserve HT Series Reverse Osmosis System Operator’s Guide 6925 Canoga Avenue, Canoga Park, CA 91303 (800) 594-3300 Page 10 PLUMBING

Puroserve HT Series Reverse Osmosis System Operator’s Guide

6925 Canoga Avenue, Canoga Park, CA 91303www.Puroserve.com (800) 594-3300 Page 3

UNIT SPECIFICAITIONS

MODEL

HT600

DESIGN CONDITIONS

PERMEATE FLOW CONC. FLOW

DESIGN

RECOVERY*GPD GPM

600 0.42

GPM (%)

50%0.42

PLUMBING

INLET

(Inches)(Inches)

OUTLET

1/2” 3/8”

Electrical

Voltage LoadControlVoltage

110 <1 24

AC Amps AC

Plumbing with HQ-800H 1” Pump

INLET

(Inches) (Inches)

OUTLET

1” 1”

Voltage

AC

Load

Amps

110 9

Unit Operating Parameters

Unit rated at 77 °F (25°C) at 500 part per million (PPM) total dissolved solids (TDS) operating at 80 psi. (5.62kg/cm ) pressure. Unit capacity changes significantly with water temperature. For higher TDS, a water analysis must beperformed and could result in modifications to the unit.

Minimum feed pressure to unit: 80 psi.

Chlorine must be removed if present in feed water prior to RO with a carbon filter or with chemical injection.

Feed water turbidity: less than 1 NTU; feed water silt density index (SDI) : 5 maximum. If exceeded, pretreatment withmedia filter recommended. All pretreatment equipment and SDI test kits are available from Puroserve.

Capacity Basis: 24 hours/day.

Unit Design Notes

Permeate Flow: indicated design flow rate from RO membranes as product water for use.

Concentrate Flow: water flowing to the drain. Concentrate flow is critical for proper unit operation. For properconcentrate flows, refer to unit design information above.

!

!

System pressure is a variable. It is important to adjust the pressure to get the correct permeate & concentrate flows. The exact value of the pressure is not important.

Permeate flow will increase at higher temperatures.

Feed waterTempurature Correction

Factor C° F°

5 41.0 2.58 6 42.8 2.38 7 44.6 2.22 8 46.6 2.11 9 48.2 2.00 10 50.0 1.89 11 51.8 1.78 12 53.6 1.68 13 55.4 1.61 14 57.2 1.54 15 59.0 1.47 16 60.8 1.39 17 62.6 1.34

18 64.4 1.29 19 66.2 1.24 20 68 1.19 21 69.8 1.15 22 71.6 1.11 23 73.4 1.09 24 75.2 1.04 25 77.0 1.00 26 78.8 .97 27 80.6 .94 28 82.4 .91 29 84.2 .88 30 86.0 .85

Feed waterTempurature

C° F°Correction Factor

2

* Recovery=Production vs. Waste/Reclaim 50%

Page 4: Permeate Concentrate HT SERIES - Puroserve · Puroserve HT Series Reverse Osmosis System Operator’s Guide 6925 Canoga Avenue, Canoga Park, CA 91303 (800) 594-3300 Page 10 PLUMBING

Puroserve HT Series Reverse Osmosis System Operator’s Guide

6925 Canoga Avenue, Canoga Park, CA 91303www.Puroserve.com (800) 594-3300 Page 4

Operating Do’s and Dont’s

Do: 1. Change the filter elements regularly. 2. Monitor the unit and, ideally, keep a monthly log. 3. Run the unit as often as possible on a continuous basis.

Don’t: 1. Shut down the unit for extended periods of time. 2. Close the drain flow adjustment valve completely. 3. Operate the unit with insufficient flow.

Unit AutomationThe unit will automatically turn on when the water level in the pearmeate tank reaches the mid level float, and willturn off when the water meets the high level float switch.

There are two (2) float switches on the unit. 1. High level float switch: Signals when the tank is full and shuts down the unit. 2. Low level float switch: Signals when to turn the unit on.

Example of Typical Start-up Sequence

1. The water in the atmospheric tank drops to a low level. 2. A solenoid opens to allow the feed water into the unit. 3. Permeate and concentrate flows are determined by the drain flow adjustment valve manually. 4. The unit will continue to run until the level in the tank activates the high level float switch, at which point it will shut itself off.

Unit Shut-Down

1. Shut the water supplying the unit off. 2. Unplug the unit from the wall. 3. If the unit is to be shut down for more than two weeks a membrane preservative should be used. Refer to the instructions for preserving the membrane(s).

Unit Monitoring and Maintenance Record Keeping

The unit should be monitored and all pertinent data recorded on a monthly basis. Data is needed to determine the operating efficiency and for performing maintenance. Maintenance includes cleaning of the membrane, adjustment ofthe drain flow, and replacing the sediment and carbon filter elements on a regular basis. Use the RO service record form included in this manual.* Membrane warranty claims cannot be processed without adequate operating data and history of the RO unit.

Page 5: Permeate Concentrate HT SERIES - Puroserve · Puroserve HT Series Reverse Osmosis System Operator’s Guide 6925 Canoga Avenue, Canoga Park, CA 91303 (800) 594-3300 Page 10 PLUMBING

Puroserve HT Series Reverse Osmosis System Operator’s Guide

6925 Canoga Avenue, Canoga Park, CA 91303www.Puroserve.com (800) 594-3300 Page 5

Product Feed Drain3/8” 1/2” 3/8”

City PSI Pump PSI

ConcentrateAdjustment

Permeate Concentrate

HT SERIES

Membrane

Drain �ow adjustment valve

Permeate & Concentrate �ow meters

5 Micron Sediment

5 Micron Carbon Block

21.5”

8.5”

8”

24.5”

FOR ILLUSTRATION PURPOSES ONLY.

Page 6: Permeate Concentrate HT SERIES - Puroserve · Puroserve HT Series Reverse Osmosis System Operator’s Guide 6925 Canoga Avenue, Canoga Park, CA 91303 (800) 594-3300 Page 10 PLUMBING

Puroserve HT Series Reverse Osmosis System Operator’s Guide

6925 Canoga Avenue, Canoga Park, CA 91303www.Puroserve.com (800) 594-3300

GENERAL INFORMATION AND SAFETY

WARNINGFlush the system for at least 30 minutes before use.

CAUTIONTo avoid electrical shock, disconnect the unit fromthe 110vac power source prior to servicing the unit.

WARNINGDo not make any modifications or alterations to thewiring or plumbing of the system. This can result indamage to the system and cause injury to the operators or users.

CAUTIONThis unit is designed to operate at 80 PSI. To help avoid water damage and damage to thesystem ensure all tubing is secured and keptaway from sharp objects and heat.

System Installation

Location Select a location for the unit with adequate clearance around the unit and where studs are present.

Use a stud finder and the included mounting template to determine hole spacing and placement.

The height needs to be no less that four feet from the ground when mounting to allow service to the unit.

Mounting Ensure your hole spacing is correct and lined up with a stud before affixing the unit to the chose space.

If studs are unavailable then other means will need to be discussed with your Puroserve representative in order to properly hang the unit and ensure safety and strength.

Electrical A grounded 110vac power outlet is required to supply the unit and pumps with power. The 110vac power outlet

should be on a dedicated 15 amp breaker.

Plumbing The HT600 features flexible tubing as its primary plumbing. Using a combination of 1/2” tubing (Inlet) and 3/8” tubing (Outlet) plumbing is made simple and tidy. Other options for material and installation can be made available by discussing it with your Puroserve representative.*

*Contact your Puroserve representative for optional drain features compatible with the HT series.

Page 6

Page 7: Permeate Concentrate HT SERIES - Puroserve · Puroserve HT Series Reverse Osmosis System Operator’s Guide 6925 Canoga Avenue, Canoga Park, CA 91303 (800) 594-3300 Page 10 PLUMBING

Puroserve HT Series Reverse Osmosis System Operator’s Guide

6925 Canoga Avenue, Canoga Park, CA 91303www.Puroserve.com (800) 594-3300 Page 7

Product Water Storage Tank Float Switch Installation

1. Carefullly place the float switch tree assembly inside the storage tank.

2. Align the threaded end of the float tree with the hole near the top of the tank and ensure the threadedend protrudes through the tank.

3. Attach the provided white nut to the threaded end of the float tree and firmly tighten down.

4. Connect one end of the provided communications cable to the system control box located underthe unit and the other end of the communications cable to the protruding end of the float switch tree.

! Make sure all electrical components are in accordance with the NESC guidelines

as dictated by the authorities holding proper jurisdiction in your community.

Alignment pinsfor float tree plug

Tank wallmounting hole

Plastic nut

Jackto systemcontroller

Plug to system controller

Float switch tree

Inside of storage tank

White plastic nut

Systemcontrolboxlocation

Rear of unit

Float tree plug locationon system control box

System control box

Page 8: Permeate Concentrate HT SERIES - Puroserve · Puroserve HT Series Reverse Osmosis System Operator’s Guide 6925 Canoga Avenue, Canoga Park, CA 91303 (800) 594-3300 Page 10 PLUMBING

Puroserve HT Series Reverse Osmosis System Operator’s Guide

6925 Canoga Avenue, Canoga Park, CA 91303www.Puroserve.com (800) 594-3300

160g Tank

High level float switch (Deactivates Unit)

Low level float switch (Activates Unit)

City PSI Pump PSI

ConcentrateAdjustment

Permeate Concentrate

HT SERIES

Product Feed Drain

Side Panel

Product/Permeate

Drain

Feed line

To point of use

Ozone

120VAC

Communications Cable

For Illustration Purposes Only

Page 8

Page 9: Permeate Concentrate HT SERIES - Puroserve · Puroserve HT Series Reverse Osmosis System Operator’s Guide 6925 Canoga Avenue, Canoga Park, CA 91303 (800) 594-3300 Page 10 PLUMBING

Puroserve HT Series Reverse Osmosis System Operator’s Guide

6925 Canoga Avenue, Canoga Park, CA 91303www.Puroserve.com (800) 594-3300 Page 9

PLUMBING

!

!

All plumbing must be in accordance with state and local codes.

This unit produces high-quality water that must be neutralized to preventleaching of the plumbing following the system. Make sure to use plumbing materials suitable for your specific application.

Materials

The HT600 is designed as a point of use system and uses linear low-density polyethylene tubing (LLDPE). All materials used in the plumbing phase should be rated for potable water use.

Plumbing materials can significantly contribute to the contamination of the water. Take the time to choose the right kind of material for your application. Teflon tape is suitable for all threaded connections in this system.

Copper is not to be used after the system for the product/permeate stream as the quality of the water can corrode the copper over time. If copper is to be used ensure there is calcite or an equivalent nuetralizing filter after the system and before going back into the copper.

Typical installation plumbing materials consists of a combination of Polypropylene tubing, Pex , schedule 40 or 80 if desired. To request specific or optional plumbing materials speak with your Puroserve sales representative.

R

R

Feed Water Connection

Connect the raw water supply to the port labled (Feed) on the HT600 RO system, making sure the tubing is firmly inserted and seated.

A manual valve should be installed on this line to shut off the water supply when needed for service. Be sure the valve in no way restricts the water flow when it is fully open.

Minimum working water pressure must be at least 80 psi. Maximum static water pressure must be no more than 100 psi. A boost pump may be required for pressure less than 65psi. A pressure regulator may be required for pressure above 100 psi.

Product Feed Drain

Side Panel

Page 10: Permeate Concentrate HT SERIES - Puroserve · Puroserve HT Series Reverse Osmosis System Operator’s Guide 6925 Canoga Avenue, Canoga Park, CA 91303 (800) 594-3300 Page 10 PLUMBING

Puroserve HT Series Reverse Osmosis System Operator’s Guide

6925 Canoga Avenue, Canoga Park, CA 91303www.Puroserve.com (800) 594-3300 Page 10

PLUMBING (CONTINUED)

Permeate/Product

Connect permeate outlet (located on the left hand side of the HT600) to the elbow located on the top of the storage tank. See Fig A.

Concentrate/Drain

Connect concentrate outlet (located on the left hand side of the HT600) labled (Drain) to a suitable drain using 3/8” O.D. tubing or larger. See Fig B

Product Feed Drain

Side Panel

FigA FigB

!

!

To avoid damage to the membrane, tubing should not exceed a height of 4 feetabove the top of the membrane housing.

Be sure to install an overflow drain to the storage tank at the highest point possible.Drain to the outside drain for protection against overfilling due to possible floatfailure. 1/2” drain line should be sufficient.

Page 11: Permeate Concentrate HT SERIES - Puroserve · Puroserve HT Series Reverse Osmosis System Operator’s Guide 6925 Canoga Avenue, Canoga Park, CA 91303 (800) 594-3300 Page 10 PLUMBING

Puroserve HT Series Reverse Osmosis System Operator’s Guide

6925 Canoga Avenue, Canoga Park, CA 91303www.Puroserve.com (800) 594-3300 Page 11

INITIAL SYSTEM STARTUP

1. Direct your product water tubing to the drain

2. Turn the drain valve counter clockwise all the way.

3. Open the feed water supply valve. System will be on.

4. Note inlet pressure must be at least 80 psi.

5. If incoming pressure is too high, an inlet pressure regulator (Not Included) should be installed. This should be set to 80 psi.

6. Some fittings may have loosened during shipment. Check for leaks at all tube fitting and threaded joints.

7. Allow the unit to run for at least 20-30 minutes to flush any remaining preservative solution from the unit.

8. Once the preservative solution has been flushed from the unit, shut it down by turning off the dee water and re-directing the permeate/product tube to the elbow at the top of the storage tank.

9. Adjust the drain flow valve clockwise to get the desired permeate/product rate. NEVER close the valve completely----you will damage the membrane.

10. Run unit and check again for leaks, which should be repaired prior to placing the unit in service.

11. Once all the desired flow rates are set, allow the unit to run for approximately 30 minutes. Then record the performance information using the RO service record included in this manual. The values recorded at startup will be important for detirmining unit performance at a later date.

!

!

!

If the pump chatters loudly it is starving for water (cavitating). Unplug the pump immediately to prevent pump damage. Correct the low pressure condition before proceeding.

DO NOT operate the unit with the drain flow valve closed.

If the pump does not shut off, turn the unit off immediatelyto prevent pump damageUnplug the pumps’ power source, then check the wiring and replace or adjust switchas needed.

Page 12: Permeate Concentrate HT SERIES - Puroserve · Puroserve HT Series Reverse Osmosis System Operator’s Guide 6925 Canoga Avenue, Canoga Park, CA 91303 (800) 594-3300 Page 10 PLUMBING

Puroserve HT Series Reverse Osmosis System Operator’s Guide

6925 Canoga Avenue, Canoga Park, CA 91303www.Puroserve.com (800) 594-3300 Page 12

SERVICE MAINTENANCE PROCEDURES (To be performed by a Puroserve-trained technician)

Items Required 1. 20” 5-micron sediment �lter 2. 20” 5-micron carbon block (Chloraguard) 3. Silicone lubricant (O-rings) 4. Filter wrench 5. 4 ounces of chlorine (12% concentration preferred) 6. A 4-6 foot ladder

Take Note of: a. City psi. b. Pump psi. c. Any visable leaks d. Tank level

If unit is not in run mode, actuate the �oat switches in the tank or use a test box (technician tool).

With system in run mode observe the following: a. Product (permeate) �ow rate b. Drain (concentrate) �ow rate c. City psi. d. Proper function of the ozone generator

Sediment �lter and carbon block replacement. a. Turn the unit o� by closing the feed water valve. b. City psi. gauge should read zero. c. Using a �lter wrench loosen the two sediment �lter housings turning counter-clockwise. d. Remove and inspect the �lter elements. e. Put 1 cap full of the chlorine and �ll the housing to the top while agitating the mixture. f. Allow the mixture to sit for 10 minutes followed by a thorough rinse until the chlorine is no longer present. g. Place the new 5-micron sediment �lter and carbon block into their respective housings. h. Use a light coat of silicone lubricant to seat the O-ring into its groove. i. Twist the �lter housing clockwise back onto the unit ensuring it is hand tight.

SedimentHousingCap

Sediment Pre-FilterCartridge

SedimentHousing

O Ring Seal

Page 13: Permeate Concentrate HT SERIES - Puroserve · Puroserve HT Series Reverse Osmosis System Operator’s Guide 6925 Canoga Avenue, Canoga Park, CA 91303 (800) 594-3300 Page 10 PLUMBING

Puroserve HT Series Reverse Osmosis System Operator’s Guide

6925 Canoga Avenue, Canoga Park, CA 91303www.Puroserve.com (800) 594-3300 Page 13

SERVICE MAINTENANCE PROCEDURES (CONTINUED)

Membrane Air Scrubbing

a. Once the sediment housings are properly reinstalled, open the drain �ow control valve all the way turning counter-clockwise. b. Divert the permeate/product outlet to a drain. c. Open the feed line valve completely allowing the air from the sediment housing into the membrane housing. d. Once the air bubble are seen through the rotameter allow it run until the bubbles begin to slow. e. Once the bubbles have slowed, close the feed line valve completely and allow the unit to sit for 20-30 seconds. f. Repeat this process two additional times to allow all the air to scrub the membrane and exit to drain. g. When the air scrub process is complete replace the permeate line to its outlet and open the feed line valve. h. Allow the unit to run for 2-3 minutes then adjust the drain �ow valve at a 1:1 ratio.

Test Functionality of the Ozone Generator

a. Ensure the ozone generator is running and the tubing is not blocked. b. Ensure the stone is attached at the other end of the line hanging, mid length, in the storage tank.

OZONE GENERATOR SETUP

a. Locate the on/off rocker switch on the right hand side of the ozone generator in Figure 1 labeled (A).

b. Ensure the rocker switch is switched on (red illumination from on/off switch).

c. The ozone generator will run for exactly 5 minutes every 24 hours from when the rocker switch is first initiated.

Air inlet (DO NOT BLOCK)

Ozone Out

FIG. 1

A. Rocker Switch

Page 14: Permeate Concentrate HT SERIES - Puroserve · Puroserve HT Series Reverse Osmosis System Operator’s Guide 6925 Canoga Avenue, Canoga Park, CA 91303 (800) 594-3300 Page 10 PLUMBING

Puroserve HT Series Reverse Osmosis System Operator’s Guide

TROUBLESHOOTING

No Water To Home?

Could Be: a. No power to unit b. Repressurization pump failure c. Manual bypass valve is off

Solutions: a. Check power supply b. Check operation of pump (consult pump manual) c. Check position of bypass

Water Conditioning, Inc.6925 Canoga Avenue, Canoga Park, CA 91303

www.puroserve.com | (800) 594-3300

Unit in Bypass, No Water in Storage Tank?

Could Be: a.Excessive water usage b. Water production failure c. Level switch failure

Solutions: a. Check home for leaks b. Determine customer’s consumption c. Check operation of level switches

Low or No Water Production?

Could be: a. Insufficient feed PSI b. Sediment cartridge plugged c. Carbon block cartridge plugged d. Membrane scaled e. Inlet solenoid failure

Solutions: a. Check that incoming PSI is at least 80 PSI during production b. Check and change sediment cartridge as needed c. Check and change carbon block cartridge as needed d. Replace or de-scale membrane as needed e. Ensure the inlet solenoid valve is opening properly

High TDS? (After Membrane)

Could be: a. Membrane worn

Solution: a. Replace membrane

Page 14

Page 15: Permeate Concentrate HT SERIES - Puroserve · Puroserve HT Series Reverse Osmosis System Operator’s Guide 6925 Canoga Avenue, Canoga Park, CA 91303 (800) 594-3300 Page 10 PLUMBING

Puroserve HT Series Reverse Osmosis System Operator’s Guide

6925 Canoga Avenue, Canoga Park, CA 91303www.Puroserve.com (800) 594-3300 Page 15

49”

81”72”66”

81”

23” 23” 28” 31” 35”

75 Gallons 130 Gallons 160 Gallons 200 Gallons 300 Gallons

Page 16: Permeate Concentrate HT SERIES - Puroserve · Puroserve HT Series Reverse Osmosis System Operator’s Guide 6925 Canoga Avenue, Canoga Park, CA 91303 (800) 594-3300 Page 10 PLUMBING

Water Conditioning, Inc. 6925 Canoga Avenue Canoga Park, CA 91303www.puroserve.com (800) 594-3300

RO Service Record InformationModel: Installation Date:

Installed by:

Contact: Phone:

Pre Filter(s) Changed

Yes No

Membrane(s) Changed

Yes No

CityPressure

PSI

Concentrate/Permeate Flow Rate

GPM GPM

Calcite Topped O

Yes No

Service

Date Technician Yes No

Pump Kick On Pressure

Delivery psi Boost psi

CarbonChange

Notes

Page 30Page 16