pg15036_a01-a17 allure maribyrnong proposed showroom
TRANSCRIPT
perm
it iss
ue
SITE PLANScale 1:1500
ProjectClientDRAWN
CHEKED
APPROVED
SCALE
REVISION
JOB No
SHEET
· Planning/building design· Civil engineering· Structural engineering· Project management
PLATINUM GROUP DESIGNSuite 3, 71 Oxford Street, Collingwood Vic. 3066
Ph: (03) 9417 1220 / Fax: (03) 9417 1397
Drawing Title
DESIGN
© Copyright Platinium Group Design Pty. Ltd. This drawing shall not be copied or modified in whole or in part without the prior written permission of Platinum Group Design Pty. Ltd.
DATE
REV. DESCRIPTION BY DATE
NOVEMBER 2015 A01PG15036
L.D'AMICO
A3 1:500
1 OF 17 1
ALLURE BATHROOM8A/169 ROSAMOND RDMARIBYRNONG (VIC) 3032
PROPOSED SHOWROOMTENANCY 8A, 169 ROSAMOND RDMARIBYRNONG (VIC) 3032
LOCALITY PLAN AND INDEX
N
WHITE STREET
CO
ULSO
N C
LOSE
ROSA
MO
ND
RO
AD
INDEXA01 LOCALITY PLAN AND INDEXA02 GENERAL NOTESA03 EXISTING AND DEMOLITION PLANA04 PROPOSED OVERALL FLOOR PLANA05 PROPOSED FLOOR PLAN - AREA 1A06 PROPOSED FLOOR PLAN - AREA 2A07 PROPOSED FLOOR FINISHES PLAN - AREA 1A08 PROPOSED FLOOR FINISHES PLAN - AREA 2A09 PROPOSED FLOOR AREAS AND SET-OUT PLAN - AREA 1A10 PROPOSED FLOOR AREAS AND SET-OUT PLAN - AREA 2A11 EXISTING AND DEMOLITION REFLECTIVE CEILING PLANA12 PROPOSED REFLECTIVE CEILING PLAN AREA 1A13 PROPOSED REFLECTIVE CEILING PLAN AREA 2A14 COUNTER. PLAN VIEW.A15 PROPOSED SIGNAGE PLAN.A16 PROPOSED EAST ELEVATION AND DETAIL PLAN.A17 PROPOSED WEST ELEVATION AND DETAIL PLAN.
A FOR INFORMATION L.D. 10/11/15
8A/169 ROSAMOND RDPROPOSED SHOWROOM AT
MARIBYRNONG (VIC)3032
TEN
AN
CY
8A
TEN
AN
CY
8B
TEN
AN
CY
7
NEW ALLURE SHOWROOM
B FOR INFORMATION L.D. 16/11/151 FOR BUILDING PERMIT ISSUE L.D. 20/11/152 FOR BUILDING PERMIT ISSUE L.D. 27/11/15
perm
it iss
ue
ProjectClientDRAWN
CHEKED
APPROVED
SCALE
REVISION
JOB No
SHEET
· Planning/building design· Civil engineering· Structural engineering· Project management
PLATINUM GROUP DESIGNSuite 3, 71 Oxford Street, Collingwood Vic. 3066
Ph: (03) 9417 1220 / Fax: (03) 9417 1397
Drawing Title
DESIGN
© Copyright Platinium Group Design Pty. Ltd. This drawing shall not be copied or modified in whole or in part without the prior written permission of Platinum Group Design Pty. Ltd.
DATE
REV. DESCRIPTION BY DATE
NOVEMBER 2015 A02PG15036
L.D'AMICO
A3
2 OF 17 2
ALLURE BATHROOM8A/169 ROSAMOND RD,MARIBYRNONG (VIC) 3032
PROPOSED SHOWROOMTENANCY 8A 169 ROSAMOND RDMARIBYRNONG (VIC) 3032
GENERAL NOTES
GENERAL NOTES
A FOR INFORMATION L.D. 10/11/15
16. ALL STEPS, STAIRS, LANDINGS, HANDRAILS ANDBALUSTRADES SHALL CONFORM WITH D 2.13 D 2.16AND D 2.7 OF THE BCA.17. BUILDER MUST COMPLY WITH LOCALAUTHORITIES MUNICIPAL BY-LAWS, VICTORIANREGULATIONS AND THE BUILDING CODE OFAUSTRALIA.18. ALL WORK SHALL BE CARRIED OUT IN ATRADESMAN LIKE MANNER AND COMPLY WITHRELEVANT CODES AND TO THE SATISFACTION OF THERELEVANT BUILDING SURVEYOR.19. STRUCTURAL FRAMING, FIXING, BRACING ANDSUPPORTS TO BE IN ACCORDANCE WITH RELEVANTAUSTRALIAN STANDARDS, CODES AND GOODBUILDING PRACTICE.20. DENOTES - 250 MM DIAMETER EXHAUST FAN. AIRTO BE EXTRACTED TO OUTSIDE AIR AND TO PROVIDEFRESH AIR AT THE RATE OF 10 M3 PER HOUR.21. ALL SERVICE PIPES TO BE CONCEALED ININTERNAL DUCTS, STUD WALLS OR FLOOR SPACEWITHIN EXTERNAL WALLS.
1. ARCHITECTURAL DRAWINGS TO BE READ INCONJUNCTION WITH STRUCTURAL ENGINEER'SDRAWINGS AND COMPUTATIONS.2. ALL LEVELS RELATE TO AUSTRALIAN DATUM. REFERTO SURVEYOR'S DRAWINGS.3. DO NOT SCALE DRAWING, FIGURED DIMENSIONSTO TAKE PREFERENCE OVER SCALED SIZES.4. CLASSIFICATION - RESIDENTIAL CLASS 1 &10.5. RISE IN STOREY - 2 NO.6. STOREY'S CONTAINED - 2 NO.7. ALL GLAZING TO COMPLY TO AS1288.8. ALL CONCRETE TO COMPLY TO AS3600.9. ALL BRICKWORK TO COMPLY TO AS3700.10. ALL STRUCTURAL TIMBERS TO COMPLY TOAS1684, AND TO VICTORIAL TIMBER FRAMINGMANUAL.11. ALL BRICK VENEER WALLS (REFER TO INSULATIONNOTES)
AND LINED INTERNALLY;C. R2.5 BULK INSULATION INSTALL UNDERFLOOR;42. LAUNDRIES, BATHROOMS, ENSUITES ANDPOWDER ROOMS THAT ARE NOT NATURALLYVENTILATED, SHALL BE PROVIDED WITHMECHANICAL VENTILATION;43. THE STORM WATER DISCHARGE SHALL BECONNECTED TO THE EXISTING LEGAL POINT OFDISCHARGE;44. THE GROUND BENEATH THE SUSPENDED FLOORMUST BE GRADED SO THAT THE AREA BENEATH THEBUILDING IS ABOVE THE ADJACENT EXTERNALFINISHED GROUND LEVEL AND SURFACE WATER ISPREVENTED FROM PONDING UNDER THE BUILDING.ALTERNATIVELY, AGRICULTURAL PIPES SHALL BEPROVIDED BENEATH THE BUILDING TO DRAINPONDING SURFACE WATER. SURFACE WATERMUST BE DIVERTED AWAY FROM ASLAB-ON-GROUND, SO THAT THE ADJACENTEXTERNAL FINISHED SURFACE SURROUNDING THESLAB MUST BE DRAINED TO MOVE SURFACE WATERAWAY FROM THE BUILDING AND GRADED TO GIVEA SLOPE OF NOT LESS THAN 50MM OVER THE FIRST1M FROM THE BUILDING;
12. DENOTES SMOKE DETECTOR.SMOKE DETECTOR TO BE PLACED ON CEILING ASINDICATED ON PLAN AN DIRECTLY WIRED TO POWERSUPPLY WITH BATTERY BACK UP.13. THE BUILDER SHALL BE RESPONSIBLE FOROBTAINING ALL RELEVANT PERMITS AND APPROVALSFROM RELEVANT AUTHORITIES, INCLUDINGINSPECTIONS AT APPROPRIATE STAGES OFCONSTRUCTION.14. ANY VARIATIONS MUST BE APPROVED BY THECLIENT/ DESIGNER PRIOR TO PROCEEDING.15. ALL VICTORIAN WORKCARE - OCCUPATIONALHEALTH AND SAFETY DIVISION CODES OF PRACTICEARE TO BE COMPLIED WITH.
31. THE DOOR TO A FULLY ENCLOSED SANITARYCOMPARTMENT SHALL OPEN OUTWARDS, SLIDE ORBE READILY REMOVABLE FROM THE OUTSIDE OF THECOMPARTMENT, IE REMOVABLE HINGES.32. THE STUMPS ARE REQUIRED TO BE BRACED INACCORDANCE WITH AS 1684 - 1992, IF THE HEIGHTOF THE STUMP FROM NATURAL GROUND LEVEL TOTHE UNDERSIDE OF THE BEARER EXCEEDS THE RATIOOF 15 TIMES THE WIDTH OF THE STUMP, IE A 100 X 100STUMP HAS A MAXIMUM HEIGHT OF 1500MM.33. VERTICAL ARTICULATION JOINTS SHALL BEPROVIDED IN STRAIGHT, CONTINUOUS WALLS(HAVING NO OPENING) AT NOT MORE THAN 6MCENTRES AND LOCATED CLOSER THAN THE HEIGHTOF THE WALL AWAY FROM CORNERS. WHEREOPENINGS MORE THAN 900X900MM OCCUR, THENARTICULATION JOINTS ARE TO BE REDUCED TO 5MCENTRES AND POSITIONED IN LINE WITH AT LEAST
22. THE SITE SHALL BE ADEQUATELY FENCED OFFDURING CONSTRUCTION TO PREVENT PUBLICACCESS.23. NO PART OF THE BUILDING SHALL PROJECTBEYOND THE BUILDING LINE, IE: INCLIDING MOULDS,ARCHITECTURAL FEATURES AND THE LIKE:24. THE PREMISES SHALL BE TREATED FOR TERMITEPROTECTION USING A CHEMICAL BARRIER INACCORDANCE WITH AS3660.1-1995, ALTERNATIVELYPHYSICAL BARRIERS MAY BE ADOPTED, SUCH AS ANTCAPS OR GRANITGUARD. IF ADOPTING ANT CAPSENSURE THERE IS SUBFLOOR CLEARANCE OF 400MM.25. EVAES WITHIN 900MM (BUT NO CLOSER THAN450MM) OF THE BOUNDARY SHALL BE CONSTRUCTEDUSING NON COMBUSTABLE MATERIALS,26. EVAES EXPOSED TO WITHIN 450M OF THEBOUNDARY SHALL BE PROTECTED BY EITHER A WINGWALL OR CORBELLED BRICK WALL.27. RAINWATER HEADS, FASCIAS, GUTTERS,DOWNPIPES AND THE LIKE WITHIN 450MM 450MM 0FTHE BOUNDARY SHALL BE CONSTRUCTED OF NONCOMBUSTABLE MATERIALS.28. FLUES, CHIMNEYS, PIPES, DOMESTIC FUEL TANKS,COOLING OR HEATING APPLIANCES OR OTHERSERVICES MUST NOT BE BUILT WITHIN 450MM OF THEBOUNDARY.29. OPENINGS IN EXTERNAL WALLS WITHIN 900MMFORM THE SIDE FACING THE BOUNDARY REQUIRE TOBE PROTECTED, IE: WINDOWS SHALL BE FIXED, FIRERATED WINDOWS NO LESS THAN -/60/-.30. OPENABLE WINDOWS WITHIN 1 METRE OF THEFINISHED FLOOR LEVEL SHALL BE RESTRICTED SO THATTHE OPENINGS DO NOT PERMIT A 125MM SPHERE TOPASS THROUGH IT, IF THE FALL IS GREATER THAN 1METRE FROM THE NATURAL GROUND LEVEL.
ONE EDGE OF THE OPENING. FURTHERMORE,ARTICULATION JOINTS SHOULD BE PROVIDED AT ORNEAR CHANGES IN FOUNDATION SOIL, AT DEEPREBATES FOR SERVICE PIPES, WHERE WALLS CHANGEIN THICKNESS AND BETWEEN NEW AND OLDBRICKWORK;34. SUB FLOOR VENTILATION SHALL BE PROVIDED ATA RATE OF 7300MM2/M, WHEREIN THE MINIMUMSUB-FLOOR CLEARANCE IS 150MM;35. SMOKE DETECTORS SHALL BE A BRK 86 RAI 240VSELF-CONTAINED SMOKE ALARM OR THEEQUIVALENT TO BE CONNECTED TO THE CONSUMERPOWER MAINS IN ACCORDANCE WITH AS 3786.36. THE WALL SURFACE OF A SHOWER ENCLOSURESHALL BE IMPERVIOUS TO WATER TO A HEIGHT OF1.8M ABOVE THE FLOOR AND IMMEDIATELYADJACENT OR BEHIND A BATH, BASIN OR SINK TO AHEIGHT NOT LESS THAN 150MM ABOVE THE FIXTURE;37. ALL GLAZING SHALL BE IN ACCORDANCE WITHAS 1288-1994 WHEREIN, GLAZING WITHIN 500MM OFTHE FLOOR LEVEL SHALL BE 5MM THICKENEDANNEALED, GLAZED DOORS AND ASSOCIATED SIDEPANELS SHALL BE 5.38MM LAMINATED SAFETY GLASSAND BATHROOM WINDOWS WITHIN 1.5 OF THE BATHOR 500MM FROM THE SHOWER ENCLOSURE SHALLBE 3MM TOUGHENED SAFETY GLASS;38. STAIRS (OTHER THAN SPIRALS) SHALL BECONSTRUCTED IN ACCORDANCE WITH THEFOLLOWING:A. RISERS (R) - MAX. 190MM & MIN. 115MM;B. GOING (G) - MAX. 355MM & MIN. 240MM;C. WHERE 2R+G - MAX. 700MM & MIN. 550MM;ANDD. THE MINIMUM UNOBSTRUCTED HEAD HEIGHTFOR A STAIR SHALL BE 2000MM, MEASURED ABOVETHE NOSING OF THE TREAD.39. A LANDING NOT LESS THAN 750MM WIDE SHALLBE PROVIDED WHERE THE SILL OF A THRESHOLD OF ADOORWAY OPENS ON TO A STAIR THAT PROVIDES ACHANGE IN FLOOR LEVEL OR FLOOR TO GROUNDLEVEL GREATER THAN 3 RISERS OR 570MM.40. THE HEIGHT OF A BALUSTRADE SHALL BE NO LESSTHAN 1000MM ABOVE THE FLOOR LEVEL, BALCONYOR LANDING AND 865MM ABOVE THE NOSING OFTHE STAIR TREAD. THE SPACING OF BALUSTRADESEITHER VERTICALLY OR HORIZONTALLY SHALL NOT BEMORE THAN 125MM;41. TO SATISFY THE THERMAL INSULATION, THEFOLLOWING R VALUES MUST BE ACHIEVED;A. R4.0 BULK INSULATION TO BE INSTALLEDBETWEEN CEILING JOISTS AND LINED CEILING; ANDR2.0 BULK INSULATION BETWEEN THE STUDS
B FOR INFORMATION L.D. 16/11/151 FOR BUILDING PERMIT ISSUE L.D. 20/11/152 FOR BUILDING PERMIT ISSUE L.D. 27/11/15
K-FITTING
EM EM EM EM
H
FIRE SPRINKLER
EM
CONCEALED ALARM & SMOKE DETECTOR
ALARM SPEAKER
EMERGENCY LIGHT
EXIT SIGN
LEGEND
FIRE HYDRANTH
EXISTING FLOOR PLAN - OVERALLScale 1:200
ProjectClientDRAWN
CHEKED
APPROVED
SCALE
REVISION
JOB No
SHEET
· Planning/building design· Civil engineering· Structural engineering· Project management
PLATINUM GROUP DESIGNSuite 3, 71 Oxford Street, Collingwood Vic. 3066
Ph: (03) 9417 1220 / Fax: (03) 9417 1397
Drawing Title
DESIGN
© Copyright Platinium Group Design Pty. Ltd. This drawing shall not be copied or modified in whole or in part without the prior written permission of Platinum Group Design Pty. Ltd.
DATE
REV. DESCRIPTION BY DATE
NOVEMBER 2015 A03PG15036
L.D'AMICO
AS SHOW
3 OF 17 2
ALLURE BATHROOM8A/169 ROSAMOND RDMARIBYRNONG (VIC) 3032
PROPOSED SHOWROOMTENANCY 8A, 169 ROSAMOND RDMARIBYRNONG (VIC) 3032
EXISTING AND DEMOLITION PLAN
N
A FOR INFORMATION L.D. 10/11/15
EX. FIRE HYDRANT
2900
0 DI
STAN
CE
OF H
YDRA
NT TO
FRO
NT E
NTRY
EX. HOSE REEL
EX. HOSE REEL
EX. TOILET
TENANCY 8A
TENANCY 8B
TENANCY 7
MAIN SHOWROOM
STO
RE R
OO
MTE
NA
NC
Y 8A
TEN
AN
CY
7
EXIS
TING
CA
RPA
RK
EX. LIGHT POLE
LOADING BAY
B FOR INFORMATION L.D. 16/11/151 FOR BUILDING PERMIT ISSUE L.D. 20/11/15
perm
it iss
ue
2 FOR BUILDING PERMIT ISSUE L.D. 27/11/15
K-FITTING
PROPOSED FLOOR PLAN - OVERALLScale 1:200
ProjectClientDRAWN
CHEKED
APPROVED
SCALE
REVISION
JOB No
SHEET
· Planning/building design· Civil engineering· Structural engineering· Project management
PLATINUM GROUP DESIGNSuite 3, 71 Oxford Street, Collingwood Vic. 3066
Ph: (03) 9417 1220 / Fax: (03) 9417 1397
Drawing Title
DESIGN
© Copyright Platinium Group Design Pty. Ltd. This drawing shall not be copied or modified in whole or in part without the prior written permission of Platinum Group Design Pty. Ltd.
DATE
REV. DESCRIPTION BY DATE
NOVEMBER 2015 A04PG15036
L.D'AMICO
A3 1:200
4 OF 17 2
ALLURE BATHROOM8A/169 ROSAMOND RDMARIBYRNONG (VIC) 3032
PROPOSED SHOWROOMTENANCY 8A, 169 ROSAMOND RDMARIBYRNONG (VIC) 3032
PROPOSED OVERALL FLOOR PLAN
AREA 1 AREA 2
A FOR INFORMATION L.D. 10/11/15
EX. SINGLEENTRY DOOR
EX. AUTOMATICENTRY DOORS
EX. HOSE REEL
EX. TOILETAND
AMENITIES
EX. DOUBLEDOORS
EX. COLUMN
EX. ROLLER DOOR
1187
5 C
ON
FIRM
ON
SITE
45715 CONFIRM ON SITE 7360 CONFIRM ON SITE
1899
8 C
ON
FIRM
ON
SITE
GREET
ENTR
Y
DISPLAY
CASH WR
MEETING ROOM
CO
FFEE
TAPWARE & ACC
KIDSAREA
LOUNGE
WATER FEATURESSHOWER DISPLAY OR ALLURE DISPLAY VANITIES
BATH
W/C DISPLAYVANITIES
P.O.S.EX. HOSE REEL
EX. PLANTER BOX
TENANCY 8A700 sqm (Approx.)
TENANCY 8B
TENANCY 7
STORAGE
SINK DISPLAY
CONSULTMAJOR DISPLAY
MA
JOR
DIS
PLA
YM
AJO
R D
ISPL
AY
P.O.D.
P.O.D.
P.O.D.
DISPLAY
DISPLAY
TILES
DIS
PLA
Y
RECIEVE
WAREHOUSE
142 sqm (Approx.)
B FOR INFORMATION L.D. 16/11/151 FOR BUILDING PERMIT ISSUE L.D. 20/11/15
perm
it iss
ue
N
2 FOR BUILDING PERMIT ISSUE L.D. 27/11/15
PROPOSED FLOOR PLAN AREA1Scale 1:100
ProjectClientDRAWN
CHEKED
APPROVED
SCALE
REVISION
JOB No
SHEET
· Planning/building design· Civil engineering· Structural engineering· Project management
PLATINUM GROUP DESIGNSuite 3, 71 Oxford Street, Collingwood Vic. 3066
Ph: (03) 9417 1220 / Fax: (03) 9417 1397
Drawing Title
DESIGN
© Copyright Platinium Group Design Pty. Ltd. This drawing shall not be copied or modified in whole or in part without the prior written permission of Platinum Group Design Pty. Ltd.
DATE
REV. DESCRIPTION BY DATE
NOVEMBER 2015 A05PG15036
L.D'AMICO
A3 1:100
5 OF 17 2
ALLURE BATHROOM8A/169 ROSAMOND RDMARIBYRNONG (VIC) 3032
PROPOSED SHOWROOMTENANCY 8A, 169 ROSAMOND RDMARIBYRNONG (VIC) 3032
PROPOSED FLOOR PLAN AREA 1
A FOR INFORMATION L.D. 10/11/15
2500 3500 1700 17000 3120 4000 4000
2550 4730 14160 3389 3389 172 4100
TENANCY 8A
TENANCY 8B
TENANCY 7
1700
2500
3373
675
3628
4075
3600
4200
N
GREET
ENTR
Y
CASH WR
MEETING ROOM
CO
FFEE
KIDSAREA
LOUNGE
P.O.S.
TAPWARE & ACCWATER FEATURES
SHOWER DISPLAY OR ALLURE DISPLAY
VANITIES W/C DISPLAY
SINK DISPLAY
CONSULT
DISPLAY
DISPLAY
P.O.D.
P.O.D.
1 FOR BUILDING PERMIT ISSUE L.D. 20/11/15
perm
it iss
ue
2 FOR BUILDING PERMIT ISSUE L.D. 27/11/15
K-FITTING
PROPOSED FLOOR PLAN AREA 2Scale 1:100
ProjectClientDRAWN
CHEKED
APPROVED
SCALE
REVISION
JOB No
SHEET
· Planning/building design· Civil engineering· Structural engineering· Project management
PLATINUM GROUP DESIGNSuite 3, 71 Oxford Street, Collingwood Vic. 3066
Ph: (03) 9417 1220 / Fax: (03) 9417 1397
Drawing Title
DESIGN
© Copyright Platinium Group Design Pty. Ltd. This drawing shall not be copied or modified in whole or in part without the prior written permission of Platinum Group Design Pty. Ltd.
DATE
REV. DESCRIPTION BY DATE
NOVEMBER 2015 A06PG15036
L.D'AMICO
A3 1:100
6 OF 17 2
ALLURE BATHROOM8A/169 ROSAMOND RDMARIBYRNONG (VIC) 3032
PROPOSED SHOWROOMTENANCY 8A, 169 RODAMOND RDMARIBYRNONG (VIC) 3032
PROPOSED FLOOR PLAN AREA 2
A FOR INFORMATION L.D. 10/11/15
TENANCY 8A
TENANCY 8B
TENANCY 7
2064
1000
1000
3600
1000
1000
2200
6895 3000 150 4270 3090
1616
528
20
EX. DISABLE TOILET
N
STORAGE
EX. ROLLER DOORS
BATHDISPLAY
VANITIES
W/C DISPLAY
MA
JOR
DIS
PLA
YM
AJO
R D
ISPL
AY
P.O.D.
RECIEVE
WAREHOUSE
142 sqm (Approx.)
B FOR INFORMATION L.D. 16/11/151 FOR BUILDING PERMIT ISSUE L.D. 20/11/15
perm
it iss
ue
2 FOR BUILDING PERMIT ISSUE L.D. 27/11/15
K-FITTING
T-1
T-1
T-1
T-2
T-3
T-3
T-3
V-1
T-1
T-1
T-1
C-1
T-1
T-2
T-3
V-1
CARPET
TILE 1
TILE 2
TILE 3
VINYL 1
2.50 sqm
298 sqm
118.35 sqm
78 sqm
54.46 sqm
LEGEND
T-1 FLOOR TILESSUPPLIER: NATIONAL TILESPRODUCT: BELGIUM STONE ICE (600x600)CODE: MAXFL1130
T-2 FLOOR TILESSUPPLIER: NATIONAL TILESPRODUCT: BELGIUM STONE BRUNO (600x600)CODE: MAXFL1110
T-3 FLOOR TILESSUPPLIER: NATIONAL TILESPRODUCT: BELGIUM STONE CARBONE (600x600)CODE: MAXFL1125
V-1 VINYL FLOORSUPPLIER: POLYFLORPRODUCT: EXPONDA DESIGN - LIGHT ELMCODE: 6182
C-1 CARPET(ENTRY MAT - MARINE GRADE)
ProjectClientDRAWN
CHEKED
APPROVED
SCALE
REVISION
JOB No
SHEET
· Planning/building design· Civil engineering· Structural engineering· Project management
PLATINUM GROUP DESIGNSuite 3, 71 Oxford Street, Collingwood Vic. 3066
Ph: (03) 9417 1220 / Fax: (03) 9417 1397
Drawing Title
DESIGN
© Copyright Platinium Group Design Pty. Ltd. This drawing shall not be copied or modified in whole or in part without the prior written permission of Platinum Group Design Pty. Ltd.
DATE
REV. DESCRIPTION BY DATE
NOVEMBER 2015 A08PG15036
L.D'AMICO
A3 1:100
8 OF 17 2
ALLURE BATHROOM8A/169 ROSAMOND RDMARIBYRNONG (VIC) 3032
PROPOSED SHOWROOMTENANCY 8A, 169 ROSAMOND RDMARIBYRNONG (VIC) 3032
PROPOSED FLOOR FINISHESPLAN AREA 2
FLOOR FINISHES PLAN AREA 2Scale 1:100
A FOR INFORMATION L.D. 10/11/15
N
TENANCY 8A
TENANCY 8B
TENANCY 7
STORAGE
EX. DISABLE TOILET
B FOR INFORMATION L.D. 16/11/151 FOR BUILDING PERMIT ISSUE L.D. 20/11/15
perm
it iss
ue
FINISH FULL TILEBALANCE TO BETIMBER LOOKVINYL
2 FULL TILES
1200
2 FOR BUILDING PERMIT ISSUE L.D. 27/11/15
C-1
T-1
T-1 T-1 T-1
T-1T-1
T-1
T-1
T-1
T-1T-1
T-2
T-2
T-2
T-2 T-2
T-2
T-2
T-3 T-3 T-3
T-3T-3
T-3
T-3
T-3
T-3
V-1
V-1
T-3
T-1
T-1
T-1
T-1T-1 T-1
T-1 T-1 T-1
T-1T-1
T-1
T-1T-1
T-3
FLOOR SET-OUT PLAN AREA1Scale 1:100
ProjectClientDRAWN
CHEKED
APPROVED
SCALE
REVISION
JOB No
SHEET
· Planning/building design· Civil engineering· Structural engineering· Project management
PLATINUM GROUP DESIGNSuite 3, 71 Oxford Street, Collingwood Vic. 3066
Ph: (03) 9417 1220 / Fax: (03) 9417 1397
Drawing Title
DESIGN
© Copyright Platinium Group Design Pty. Ltd. This drawing shall not be copied or modified in whole or in part without the prior written permission of Platinum Group Design Pty. Ltd.
DATE
REV. DESCRIPTION BY DATE
NOVEMBER 2015 A09PG15036
L.D'AMICO
A3 1:100
9 OF 17 2
ALLURE BATHROOM8A/169 ROSAMOND RDMARIBYRNONG (VIC) 3032
PROPOSED SHOWROOMTENANCY 8A, 169 ROSAMOND RDMARIBYRNONG (VIC) 3032
PROPOSED FLOOR AREAS AND SET-OUT PLAN - AREA 1
A FOR INFORMATION L.D. 10/11/15
N
EX. COLUMN
ENTR
Y
TENANCY 8A
TENANCY 8B
TENANCY 7
B FOR INFORMATION L.D. 16/11/151 FOR BUILDING PERMIT ISSUE L.D. 20/11/15
perm
it iss
ue
2 FOR BUILDING PERMIT ISSUE L.D. 27/11/15
K-FITTING
T-1
T-1
T-1
T-2
T-3
T-3
T-3
V-1
T-1
T-1
T-1
ProjectClientDRAWN
CHEKED
APPROVED
SCALE
REVISION
JOB No
SHEET
· Planning/building design· Civil engineering· Structural engineering· Project management
PLATINUM GROUP DESIGNSuite 3, 71 Oxford Street, Collingwood Vic. 3066
Ph: (03) 9417 1220 / Fax: (03) 9417 1397
Drawing Title
DESIGN
© Copyright Platinium Group Design Pty. Ltd. This drawing shall not be copied or modified in whole or in part without the prior written permission of Platinum Group Design Pty. Ltd.
DATE
REV. DESCRIPTION BY DATE
NOVEMBER 2015 A10PG15036
L.D'AMICO
A3 1:100
10 OF 17 2
ALLURE BATHROOM8A/169 ROSAMOND RDMARIBYRNONG (VIC) 3032
PROPOSED SHOWROOMTENANCY 8A, 169 ROSAMOND RDMARIBYRNONG (VIC) 3032
PROPOSED FLOOR AREASAND SET-OUT PLAN - AREA 2
FLOOR SET-OUT PLAN AREA 2Scale 1:100
A FOR INFORMATION L.D. 10/11/15
N
EX. DISABLE TOILET
STORAGE
EX. ROLLER DOORS
TENANCY 8A
TENANCY 8B
TENANCY 7
TEN
AN
CY
7B FOR INFORMATION L.D. 16/11/151 FOR BUILDING PERMIT ISSUE L.D. 20/11/15
perm
it iss
ue
2 FOR BUILDING PERMIT ISSUE L.D. 27/11/15
K-FITTING
EM EM EM EM
FIRE SPRINKLER
EM
CONCEALED ALARM & SMOKE DETECTOR
ALARM SPEAKER
EMERGENCY LIGHT
EXIT SIGN
LEGEND
FIRE HYDRANTH
EXISTING LIGHTS (TO BE REMOVED)
CEILING TILES TO BE REMOVED
EX. REFLECTIVE CEILING PLAN Scale 1:200
ProjectClientDRAWN
CHEKED
APPROVED
SCALE
REVISION
JOB No
SHEET
· Planning/building design· Civil engineering· Structural engineering· Project management
PLATINUM GROUP DESIGNSuite 3, 71 Oxford Street, Collingwood Vic. 3066
Ph: (03) 9417 1220 / Fax: (03) 9417 1397
Drawing Title
DESIGN
© Copyright Platinium Group Design Pty. Ltd. This drawing shall not be copied or modified in whole or in part without the prior written permission of Platinum Group Design Pty. Ltd.
DATE
REV. DESCRIPTION BY DATE
NOVEMBER 2015 A11PG15036
L.D'AMICO
A3 1:100
11 OF 17 2
ALLURE BATHROOM8A/169 ROSAMOND RDMARIBYRNONG (VIC) 3032
PROPOSED SHOWROOMTENANCY 8A, 169 ROSAMOND RDMARIBYRNONG (VIC) 3032
EXISTING AND DEMOLITION REFLECTIVE CEILING PLAN
N
A FOR INFORMATION L.D. 06/11/15
1187
5 C
ON
FIRM
ON
SITE
45715 CONFIRM ON SITE
TENANCY 8A
TENANCY 8B
TENANCY 7
STORAGE
EXISTING600x1200mmCEILING TILES
NEW PLASTERCEILING
B FOR INFORMATION L.D. 16/11/15
4200 3090 12160 1815 10430 1815 9200 3000
3110
2065
3100
1800
1800
1800
1800
1800
4675
1800
1800
3600
4675
3600
1800
1800
4675
1800
1800
1800
2400
4675
1200
1800
1 FOR BUILDING PERMIT ISSUE L.D. 20/11/15
perm
it iss
ue
13295
1817 6335
1815 1815
2 FOR BUILDING PERMIT ISSUE L.D. 27/11/15
EM EM EM
PL2 PL2 PL2 PL2
PL2
PL1 PL1
PL2
LEGENDPL1
LEGEND
FIRE SPRINKLER
EM
CONCEALED ALARM & SMOKE DETECTOR
ALARM SPEAKER
EMERGENCY LIGHT
EXIT SIGN
PENDANT PL1 @1900 AFFL
PENDANT PL2 @ 1900 AFFL
LARGE LED DOWNLIGHT - 500 LUX AT 1100'PIN' LED DOWNLIGHTSANGLED SPOTS - 1000 LUX
REFLECTIVE CEILING PLAN AREA1Scale 1:100
ProjectClientDRAWN
CHEKED
APPROVED
SCALE
REVISION
JOB No
SHEET
· Planning/building design· Civil engineering· Structural engineering· Project management
PLATINUM GROUP DESIGNSuite 3, 71 Oxford Street, Collingwood Vic. 3066
Ph: (03) 9417 1220 / Fax: (03) 9417 1397
Drawing Title
DESIGN
© Copyright Platinium Group Design Pty. Ltd. This drawing shall not be copied or modified in whole or in part without the prior written permission of Platinum Group Design Pty. Ltd.
DATE
REV. DESCRIPTION BY DATE
NOVEMBER 2015 A12PG15036
L.D'AMICO
A3 1:100
12 OF 17 2
ALLURE BATHROOM8A/169 ROSAMOND RDMARIBYRNONG (VIC) 3032
PROPOSED SHOWROOMTENENACY 8A, ROSAMOND RDMARIBYRNONG (VIC) 3032
PROPOSED REFLECTIVECEILING PLAN AREA 1
A FOR INFORMATION L.D. 10/11/15
N
TENANCY 8A
TENANCY 8B
TENANCY 7
EX. COLUMN
ENTR
Y
EXISTING600x1200mmCEILING TILES
PLASTERBOARD FLUSHPLASTERBOARD
WATER FEATURESBELOW
CASH WRBELOW
SINK DISPLAYBELOW
SHOWERDISPLAY
DISPLAYBELOW
VANITIESBELOW
FLOORPATTERN
MEETING ROOMENCLOSURE
FLOORPATTERN
DISPLAYBELOW
B FOR INFORMATION L.D. 16/11/151 FOR BUILDING PERMIT ISSUE L.D. 20/11/15
perm
it iss
ue
DISPLAYBELOW
2 FOR BUILDING PERMIT ISSUE L.D. 27/11/15
K-FITTING
EM
PL2
PL2
LEGENDPL1
PENDANT PL1 @1900 AFFL
PENDANT PL2 @ 1900 AFFL
LARGE LED DOWNLIGHT - 500 LUX AT 1100'PIN' LED DOWNLIGHTSANGLED SPOTS - 1000 LUX
LEGEND
FIRE SPRINKLER
EM
CONCEALED ALARM & SMOKE DETECTOR
ALARM SPEAKER
EMERGENCY LIGHT
EXIT SIGN
ProjectClientDRAWN
CHEKED
APPROVED
SCALE
REVISION
JOB No
SHEET
· Planning/building design· Civil engineering· Structural engineering· Project management
PLATINUM GROUP DESIGNSuite 3, 71 Oxford Street, Collingwood Vic. 3066
Ph: (03) 9417 1220 / Fax: (03) 9417 1397
Drawing Title
DESIGN
© Copyright Platinium Group Design Pty. Ltd. This drawing shall not be copied or modified in whole or in part without the prior written permission of Platinum Group Design Pty. Ltd.
DATE
REV. DESCRIPTION BY DATE
NOVEMBER 2015 A13PG15036
L.D'AMICO
A3 1:100
13 OF 17 2
ALLURE BATHROOM8A/169 ROSAMOND RDMARIBYRNONG (VIC) 3032
PROPOSED SHOWROOMTENANCY 8A, 169 ROSAMOND RDMARIBYRNONG (VIC) 3032
PROPOSED REFLECTIVE CEILING PLAN AREA 2
REFLECTIVE CEILING PLAN AREA 2Scale 1:100
A FOR INFORMATION L.D. 10/11/15
N
TENANCY 8A
TENANCY 8B
TENANCY 7
STORAGE
EX. DISABLE TOILET
BATH DISPLAYBELOW
DISPLAYBELOW
FLUSHPLASTERBOARD
FLUSH PLASTERBOARD
B FOR INFORMATION L.D. 16/11/151 FOR BUILDING PERMIT ISSUE L.D. 20/11/15
perm
it iss
ue
2 FOR BUILDING PERMIT ISSUE L.D. 27/11/15
Scale 1:20
ProjectClientDRAWN
CHEKED
APPROVED
SCALE
REVISION
JOB No
SHEET
· Planning/building design· Civil engineering· Structural engineering· Project management
PLATINUM GROUP DESIGNSuite 3, 71 Oxford Street, Collingwood Vic. 3066
Ph: (03) 9417 1220 / Fax: (03) 9417 1397
Drawing Title
DESIGN
© Copyright Platinium Group Design Pty. Ltd. This drawing shall not be copied or modified in whole or in part without the prior written permission of Platinum Group Design Pty. Ltd.
DATE
REV. DESCRIPTION BY DATE
NOVEMBER 2015 A14PG15036
L.D'AMICO
A3 1:20
14 OF 17 2
ALLURE BATHROOM8A/169 ROSAMOND RDMARIBYRNONG (VIC) 3032
PROPOSED SHOWROOMTENANCY 8A, 169 ROSAMOND RDMARIBYRNONG (VIC) 3032
COUNTER. OVERVIEW PLAN
A FOR INFORMATION L.D. 23/11/15
prel
imin
ary
issue
- not
to u
se fo
r con
stru
ctio
n -
2 FOR BUILDING PERMIT ISSUE L.D. 27/11/15
TENANT
COMPUTERS - ELECTRICALFURNITURE - BEDDINGCARPET - FLOORING
TENANT
TENANT
TENANT
TENANT
TENANT
TENANT
BLK-01
DETAIL 1
ProjectClientDRAWN
CHEKED
APPROVED
SCALE
REVISION
JOB No
SHEET
· Planning/building design· Civil engineering· Structural engineering· Project management
PLATINUM GROUP DESIGNSuite 3, 71 Oxford Street, Collingwood Vic. 3066
Ph: (03) 9417 1220 / Fax: (03) 9417 1397
Drawing Title
DESIGN
© Copyright Platinium Group Design Pty. Ltd. This drawing shall not be copied or modified in whole or in part without the prior written permission of Platinum Group Design Pty. Ltd.
DATE
REV. DESCRIPTION BY DATE
NOVEMBER 2015 A15PG15036
L.D'AMICO
A3
15 OF 17 A
ALLURE BATHROOM8A/169 ROSAMOND RDMARIBYRNONG (VIC) 3032
PROPOSED SHOWROOMTENANCY 8A, 169 ROSAMOND RDMARIBYRNONG (VIC) 3032
PROPOSED SIGNAGE PLAN
A FOR INFORMATION L.D. 23/11/15
prel
imin
ary
issue
- not
to u
se fo
r con
stru
ctio
n -
KEY PLANSCALE 1:20DETAIL 2SCALE 1:20
DETAIL 3SCALE 1:100
DETAIL 3
DETAIL 1
DETAIL 2
TEN
AN
CY
8A
TEN
AN
CY
8B
TEN
AN
CY
7
ROSA
MO
ND
RO
AD
DETAIL 1.ASCALE 1:100
DETAIL 2.ASCALE 1:100
DETAIL 1.A DETAIL 2.A
6800
2200
1400
4925
700
4410
(TENANCY 8A)
EAST ELEVATIONScale 1:150
ProjectClientDRAWN
CHEKED
APPROVED
SCALE
REVISION
JOB No
SHEET
· Planning/building design· Civil engineering· Structural engineering· Project management
PLATINUM GROUP DESIGNSuite 3, 71 Oxford Street, Collingwood Vic. 3066
Ph: (03) 9417 1220 / Fax: (03) 9417 1397
Drawing Title
DESIGN
© Copyright Platinium Group Design Pty. Ltd. This drawing shall not be copied or modified in whole or in part without the prior written permission of Platinum Group Design Pty. Ltd.
DATE
REV. DESCRIPTION BY DATE
NOVEMBER 2015 A16PG15036
L.D'AMICO
AS SHOWN
16 OF 17 B
ALLURE BATHROOM8A/169 ROSAMOND RDMARIBYRNONG (VIC) 3032
PROPOSED SHOWROOMTENANCY 8A, 169 ROSAMOND RDMARIBYRNONG (VIC) 3032
PROPOSED EAST ELEVATIONAND DETAILS PLAN
A FOR INFORMATION L.D. 24/11/15
perm
it iss
ue
DETAIL 1Scale 1:50
DETAIL 2Scale 1:50
DETAIL 2DETAIL 1
B FOR INFORMATION L.D. 27/11/15
CASH DRAW
STUD WALLWITH TILEFINISHED MEETING ROOM WC DISPLAY
BATH DISPLAY
1200
1000
200
WEST ELEVATIONScale 1:150
ProjectClientDRAWN
CHEKED
APPROVED
SCALE
REVISION
JOB No
SHEET
· Planning/building design· Civil engineering· Structural engineering· Project management
PLATINUM GROUP DESIGNSuite 3, 71 Oxford Street, Collingwood Vic. 3066
Ph: (03) 9417 1220 / Fax: (03) 9417 1397
Drawing Title
DESIGN
© Copyright Platinium Group Design Pty. Ltd. This drawing shall not be copied or modified in whole or in part without the prior written permission of Platinum Group Design Pty. Ltd.
DATE
REV. DESCRIPTION BY DATE
NOVEMBER 2015 A17PG15036
L.D'AMICO
AS SHOW
17 OF 17 A
ALLURE BATHROOM8A/169 ROSAMOND RDMARIBYRNONG (VIC) 3032
PROPOSED SHOWROOMTENANCY 8A, 169 ROSAMOND RDMARIBYRNONG (VIC) 3032
PROPOSED WEST ELEVATIONAND DETAIL
A FOR INFORMATION L.D. 25/11/15
perm
it iss
ue
DETAIL 1Scale 1:50
DETAIL 2Scale 1:50
DETAIL 2 DETAIL 1
600
600
GLASS WALLSTUD WALLWITH TILEFINISHED
STUD WALLWITH TILEFINISHED
STUD WALLWITH TILEFINISHED
300
SHOWER DISPLAYS WATER FEATURES
DISPLAYSTAPWARE & ACC
CASH WR