philips heartstart frx defibrillator - microsoftlaerdalcdn.blob.core.windows.net/...philips... · 2...
TRANSCRIPT
For those who get there firstPhilipsHeartStartFRxDefibrillator
452296261601.indd 1 19-8-2010 10:05:40
The print quality of this copy is not an accurate representation of the original.
Philips HeartStart FRx Defibrillator2
Anyone, anywhere, anytime
•Thecurrentsurvivalrateforsuddencardiacarrest(SCA)isunder7%
•Thelikelihoodofsuccessfulresuscitationdecreasesbyabout10%witheveryminutethatpasses
•Itisestimatedanadditional40,000livescouldbesavedeachyearintheU.S.alonewithwidespreadaccesstoAEDs1
452296261601.indd 2 19-8-2010 10:05:49
The print quality of this copy is not an accurate representation of the original.
Philips HeartStart FRx Defibrillator 3
Anyone, anywhere, anytime
Power to save a lifeEachyearsuddencardiacarrest(SCA)strikesnearly300,000peopleintheUS,700,000peopleinEurope,andhundredsofthousandsmoreworldwide.MorepeoplediefromSCAthanfrombreastcancer,prostatecancer,housefires,handguns,trafficaccidents,andAIDScombined.
SCAcanhappentoanyone,anytime,anywhereandsometimesinextremeconditions.RelyonthePhilipsHeartStartFRxDefibrillatortobeuptothetask.Inthehandsofthosewhogettherefirst,itprovidesthepowertohelpsavealife.
Coming to the rescueIn many emergency situations, police are often the
first to arrive on the scene, and early defibrillation
by these first responders has been shown to
improve survival.2,3
Taking care of businessThirteen percent of workplace fatalities reported
in 1999 and 2000 were due to cardiac arrest.4
Protecting kids, parents and teachersAn estimated 5,000-7,000 children in the U.S.
succumb to sudden cardiac arrest annually,5 many
related to sporting events.
452296261601.indd 3 19-8-2010 10:06:09
The print quality of this copy is not an accurate representation of the original.
Philips HeartStart FRx Defibrillator4
Rugged and reliable
ThePhilipsFRxDefibrillatorfeaturestechnologicaladvancementstohelpintreatingthemostcommoncauseofSCA.It’sdesignedtobeeasytosetupanduse,aswellasruggedandreliableforthosewhogettherefirst.Onthescenewithlawenforcement,onthefieldwithstudentathletesoronthejobwithemployees,theFRxDefibrillatoristhesolutionfortreatingSCAinenvironmentsandconditionstoodemandingforotherdefibrillators.
Prescriptionrequired.
452296261601.indd 4 19-8-2010 10:06:16
The print quality of this copy is not an accurate representation of the original.
Philips HeartStart FRx Defibrillator 5
Preconnected SMART Pads II SMARTPadsIIcanbeusedforbothadultsandchildren.Theyeliminatetheexpenseofhavingtopurchasedifferentsetsofpadsfordifferentpatienttypes.SMARTPadsIIenabletheFRxtokeeppacewithrespondersbyadjustingtotheiractions.
Infant/Child keySimplyinserttheInfant/ChildkeyintotheFRxtosignaltothedevicethatyou’retreatinganinfantorachild.ThedefibrillatoradjuststoprovidespecialpadsplacementandCPRinstructions.Thepadsiconsalsoflashtoshowyoutheoptimizedpadsplacement,andthedevicereducestheshockenergytoalevelmoreappropriateforaninfantorachild.
IntuitiveCleandesignandclearvoiceinstructions,includingCPRcoaching,aredesignedtohelpinstilltheconfidencethat’sneededwhentreatingapersonincardiacarrest.
Wireless Data TransferInfrareddataportforeasytransmissiontoaSmartphoneorPCrunningEventReviewsoftware,withoutcablesorhardwirecompatibilityissues.
Bringinginnovationtothetreatmentofcardiacarrest
Proven therapyAtthecoreofallHeartStartDefibrillatorsisSMARTBiphasictechnology.ThePhilipsSMARTBiphasicwaveformishighlyeffective,yetminimizesharmfulsideeffects.Itseffectivenessisbackedbyover40published,peer-reviewedstudies.6
SMARTAnalysisautomaticallyassessesthevictim’sheartrhythmandisdesignednottodelivertherapyunlesstherhythmisdeterminedtobeshockable–eveniftheShockbuttonispressed.AndwithpatentedQuickShock,theFRxisamongthefastestinclassatdeliveringashockafterCPR.Studiesshowthatminimizingtimeto
shockafterCPRmayimprovesurvival.7,8,9,10,11AsAmericanHeartAssociationGuidelines2005note,“Reductionintheintervalfromcompressiontoshockdeliverybyevenafewsecondscanincreasetheprobabilityofshocksuccess.”12
Designed for real world useThePhilipsHeartStartFRxDefibrillatorisexceptionallyrugged.Designedtosurpassrigoroustestingrequirements,theFRxwithstandsjettingwater,loadsupto500pounds,andaone-meterdropontoconcrete.
452296261601.indd 5 19-8-2010 10:06:25
The print quality of this copy is not an accurate representation of the original.
Philips HeartStart FRx Defibrillator6
Built on a platform of proven ease-of-useTheHeartStartFRxDefibrillatorwasdesignedtobeaseasytouseastheHeartStartOnSiteDefibrillatorandsharesmanyofitsfeatures,includingCPRcoachingandintuitiveicon-drivenoperation.Smallandlightweight–just3.5lbs/1.5kg–theFRxisequippedtodirectyouthroughtheresuscitationofaSCAvictim.
TheHeartStartFRxguidesyouthrougheverystepwithclear,calmvoicecommandsanddescriptivevisualicons.TheFRxevenremindsyoutocallemergencymedicalservices(EMS).Pressingthebluei-buttonactivatesHeartStartCPRCoachingforassistancewithCPR.Theflashingiconsandthequickreferenceguidecanbeusedtoleadyouthroughthedefibrillationsteps–eveninsituationswherehearingvoiceinstructionsisachallenge.
OnceEMSarrives,hand-offisfastandeasybecausetheFRxiscompatiblewithadvanceddefibrillatorsliketheHeartStartMRx.WithHeartStartadapters,ourpadscanbepluggedintodevicesfromothermanufacturerstoensurecontinuityofcare.
Easy to set upTheHeartStartFRxReady-Packconfigurationarrivestoyoucompleteandvirtuallyreadytorescue.JustpullthegreentabtoinitiatetheFRxself-test,confirmingitsreadinessforuse,andputthedevicerightintoservice.TheFRxReady-PackcomeswiththeFRxalreadyinsideitscarrycase,padspre-connected,batteryinserted,andasetofsparepadsinplace.Set-upiseasy,andyouhavethepeaceofmindofknowingthedeviceisdeployedcorrectly.
Establishing a successful program from the startAstheworldleaderinautomatedexternaldefibrillators(AEDs),we’realsoaleaderinprovidingproductsandservicesdesignedtohelpyouestablishandmaintainasuccessfulAEDprogram,includingSMARTTrackAEDprogrammanagement,medicaldirection,accesstotrainingproviders,andpost-eventsupportoptions.
OurcustomersagreethatwithPhilips,you’rewellprepared,evenacrossmultiplesiteswithhundredsorthousandsofemployees.PhilipsexpertshavehelpeddefineindustrybestpracticesinAEDprogrammanagement,andwesupportAmericanHeartAssociationandEuropeanResuscitationCouncilguidelinesforearlydefibrillationprograms.
Designed to be the easiest-to-own AED
Easy as 1– 2 – 3 in an emergency
1Press the green
On/Off button, which
activates voice instruction
and visual icons.
2Place the pads
on the patient
as directed.
3When advised by
the device, press
the orange Shock button.
Reliability backed by PhilipsEveryHeartStartFRxgoesthrougha120-pointqualitytestbeforeitleavesthefactory.TheHeartStartFRxDefibrillatorispoweredbyaneasy-to-install,long-life(four-year)battery,soyouknowthedeviceischargedandready.Thedevice’sautomateddaily,weekly,andmonthlyself-testscheckpadreadiness,andverifyfunctionalityandcalibrationofcircuitsandsystems.Withover85tests,theFRxisoneofthemostcomprehensiveself-testingdevicesonthemarketandisvirtuallymaintenance-free.Theblinkinggreen“Ready”lightonthedefibrillatorisyourassurancethatthedevicehaspasseditslastselftestandthereforeisreadyforuse.
452296261601.indd 6 19-8-2010 10:06:29
The print quality of this copy is not an accurate representation of the original.
Philips HeartStart FRx Defibrillator 7
HeartStart FRx Defibrillator specificationsDefibrillatorDefibrillatorfamily
Order861304.Defibrillator,battery,SMARTPadsII(1set),SetupandMaintenanceGuides,OwnersManual,QuickReferenceGuide,Datesticker
HeartStartFRxReady-Packconfiguration
OrderOptionR01.Defibrillator,battery,carrycase,SMARTPadsII(1pre-connectedset,1spareset),SetupandMaintenanceGuides,OwnersManual,QuickReferenceGuide,DateSticker
Waveform TruncatedExponentialBiphasic.Waveformparametersadjustedasafunctionofeachpatient’simpedance
Therapy Adultdefibrillation:Peakcurrent32A(150Jnominalintoa50-ohmload).PediatricdefibrillationwithoptionalFRxInfant/Childkeyinstalled:Peakcurrent19A(50Jnominalinto50-ohmload)
Protocol Devicefollowspreconfiguredsettings.DefibrillationandCPRprotocolcanbecustomizedusingHeartStartEventReviewsoftware
User interfaceInstructions Detailedvoicepromptsandvisualiconsguide
responderthroughuseofthedefibrillatorCPRcoaching Voicecoachingforadultandinfant/childCPR
providesinstructionsandaudiocuesfortheappropriatenumber,rateanddepthofchestcompressions,aswellasforeachbreath
Controls GreenOn/Offbutton,bluei-button,orangeShockbutton,optionalInfant/Childkey
Indicators Readylight,bluei-button,cautionlight,illuminatedpads,icons,Shockbuttonlightsupwhenshockisadvised
PhysicalSize 2.4˝x7.1˝x8.9˝(6cmx18cmx22cm)
DxHxWWeight Withbatteryandpadscase:3.5lbs.(1.5kg)Environmental/physical requirementsSealing WaterjetproofIPX5perIEC60529
DustprotectedIP5XperIEC60529Temperature Operating/Standby:32º-122ºF(0º-50ºC)Altitude 0to15,000feetAircraft Device:RTCA/DO-160D;1997Crush 500poundsVibration Operating:meetsMILSTD810FFig.514.5C-17,
random;Standby:meetsMILSTD810FFig.514.5C-18,sweptsine
EMI(radiated/immunity)
CISPRIIGroupIClassB,IEC61000-4-3,andIEC61000-4-8
Data recording and transmissionInfrared Wirelesstransmissionofeventdatatoa
SmartphoneorPC,usingtheIrDAprotocolHeartStartEventReviewsoftware
Datamanagementsoftware(optional)fordownloadandreviewofdataretrievedthroughdefibrillator’sinfrareddataport
Datastored First15minutesofECGandtheentireincident’seventsandanalysisdecisions
Patient analysis systemPatientanalysis EvaluatespatientECGtodetermineifarhythm
isshockable.Rhythmsconsideredshockableareventricularfibrillation(VF)andcertainventriculartachycardias(VT)associatedwithlackofcirculation.Forsafetyreasons,someVTrhythmsassociatedwithcirculationwillnotbeinterpretedasshockable,andsomeverylow-amplitudeorlow-frequencyrhythmswillnotbeinterpretedasshockableVF
Sensitivity/specificity
MeetsAAMIDF80guidelinesandAHArecommendationsforadultdefibrillation
Shockadvised Abletodeliverashockassoonasthedeviceindicatesashockisadvised
QuickShock AbletodeliverashockaftertheendofaCPRinterval,typicallyin8seconds
Shock-to-Shockcycletime
Typicallylessthan20secondsbetweenshocksinaseries
Artifactdetection
AllowsaccurateECGanalysiseveninthepresenceofmostpacemakerartifactandelectricalnoisesources.Otherartifactsaredetectedandcorrectivevoicepromptsissued
Battery (M5070A)Itemnumber(s) Standard:M5070A
Aviation:989803139301(TSOC-142-U.S.only)Type 9VoltDC,4.2Ah,lithiummanganesedioxide,
disposablelong-lifeprimarycellCapacity Minimum200shocksor4hoursofoperating
time(EN60601-2-4:2003)Install-bydate Batteryislabeledwithaninstall-bydateofat
least5yearsfromdateofmanufactureStandbylife Fouryearstypicalwhenbatteryisinstalledbythe
install-bydate.(WillpowertheAEDinstandbystatewithinthespecifiedstandbytemperaturerange,assuming1batteryinsertiontestandnodefibrillationuses)
SMART Pads IIItemnumber 989803139261Activesurfacearea
12.4˝2(80cm2)each13.2˝2(85cm2)each
Cablelength 48˝(121.9cm)Use-bydate Padscaseislabeledwithause-bydateofatleast
2yearsfromdateofmanufactureInfant/ChildKey Item#989803139311Training Pads IIItemnumber 989803139271Function SpecialpadsplaceHeartStartFRxintotraining
modeanddisableitsenergydeliverycapability.Featureseightreal-worldtrainingscenarios
Automated and user-activated self-testsDailyautomaticself-tests
Testsinternalcircuitry,waveformdeliverysystem,pads,andbatterycapacity
Padsintegritytest
Specificallytestsreadiness-for-useofpads(gelmoisture)
Batteryinsertiontest
Uponbatteryinsertion,extensiveautomaticself-testsanduser-interactivetestcheckdevicereadiness
Statusindicators
Blinkinggreen“Ready”lightindicatesreadyforuse.Audible“chirp”indicatesneedformaintenance
*RefertotheHeartStartFRxDefibrillatorOwner’sManualfordetailedproductinstructions.
Allspecificationsbasedon25ºCunlessotherwisenoted.Thedefibrillatoranditsaccessoriesaremadeoflatex-freematerials.
452296261601.indd 7 19-8-2010 10:06:29
The print quality of this copy is not an accurate representation of the original.
©2010KoninklijkePhilipsElectronicsN.V.Allrightsarereserved.
PhilipsHealthcarereservestherighttomakechangesinspecificationsand/ortodiscontinueanyproductatanytimewithoutnoticeorobligationandwillnotbeliableforanyconsequencesresultingfromtheuseofthispublication.
PrintedinTheNetherlands.452296261601*JUL2010
Please visit www.philips.com/FRx for more information
1. AboutSuddenDeathandCardiacArrest.AmericanHeartAssociation.Availableat:http://www.americanheart.org/presenter.jhtml?identifier=604.AccessedJuly28,2010.
2. WhiteRD,AsplinBR,BugliosiTF,HankinsDG.Highdischargesurvivalrateafterout-of-hospitalventricularfibrillationwithrapiddefibrillationbypoliceandparamedics.Ann Emerg Med.1996;28:480-5.
3. MosessoVNJr,DavisEA,AubleTE,ParisPM,YealyDM.Useofautomatedexternaldefibrillatorsbypoliceofficersfortreatmentofout-of-hospitalcardiacarrest.Ann Emerg Med.1998;32:200-7.
4. OccupationalSafety&HealthAdministration(OSHA).www.osha.gov/dts/tib/tib_data/tib20011217.pdf.
5. BergerS,DhakaA,FriedbergDZ.SuddenCardiacDeathinInfants,ChildrenandAdolescents.Pediatric Clinics of North America.Apr.1999;46(2):221.
6. PhilipsMedicalSystems.SMARTBiphasicStudies,listedalphabeticallybystudyauthor:http://www.healthcare.philips.com/au_en/products/resuscitation/biphasic_technology/references.wpd
7. Yuetal.AdverseOutcomesofInterruptedPrecordialCompressionDuringAutomatedDefibrillation.Circulation.2002;106:368-372.
8. EftesolT,SundeK,SteenPA.EffectsofInterruptingPrecordialCompressionsintheCalculatedProbabilityofDefibrillationSuccessDuringOut-of-HospitalCardiacArrest.Circulation.2002;105:2270-2273.
9. Snyderetal.BiphasicDefibrillationWaveformCombinedwithAED-Imposed“Hands-Off”IntervalsSignificantlyAffectOutcomeFollowingProlongedCardiacArrest.Abstractfrom7thScientificCongressoftheEuropeanCouncil.2004.
10.Snyder&Morgan.CPRInterruptionIntervalVariesWidelyAmongCommerciallyAvailableAEDs.Abstractfrom7thScientificCongressoftheEuropeanCouncil,2004.
11.Snyder,D.E.andMorgan,C.WideVariationsinCardiopulmonaryResuscitationIntervalsAmongCommerciallyAvailableAutomatedExternalDefibrillatorsMayAffectSurvivalDespiteHighDefibrillationEfficacy.Critical Care Medicine.2004;32(9)Supplement:S421-S424.
12.AmericanHeartAssociation.2005AmericanHeartAssociationGuidelinesforCardiopulmonaryResuscitationandEmergencyCardiovascularCare.Circulation.2005.112:IV-36.
PhilipsisaGlobal500companyandoneoftheworld’slargestmedicalproductscompanies.
Philipshasshippednearlythree-quartersofamillionAEDunits.
PhilipsHeartStartdefibrillatorsaredeployedonairlinesandinairports,workplaces,schools,healthcarefacilities,andcommunitiesworldwide.
Philips Healthcare is part of Royal Philips Electronics
Howtoreachuswww.philips.com/[email protected]
Asia+4970314632254
Europe,MiddleEast,Africa+4970314632254
LatinAmerica+551121250744
NorthAmerica+142548770008002855585(tollfree,USonly)
HeartStartDefibrillators+197865933328002633342(tollfree,USonly)