RAB Lighting Inc. Xiao Xiang,15921313292,[email protected] Prepared By Prepared By Approved By Wangzun Zhu Kevin Jia Report Number Test Date Issue Date 2018/5/12 2018/5/12 The results contained in this report pertain only to the tested sample. This report shall not be reproduced, except in full, without written approval of Deliver Co.,Ltd. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP. Photometric Test Report Relevant Standards RANSI C82.77:2014 RIES LM-79-2008 Prepared For Room 6A33, No.1388, Wuzhong road,Shanghai ,China DLF1805109 DLF20180512001-3a Deliver Co.Ltd. Block 11, 78 Keling Road, SSTP, Suzhou, China 0512-66801950,[email protected] Project Number Doc No.: DLFLAB-ZY-01-28 Version:1.0 Page 1 of 16

Upload: others

Post on 26-Jul-2020

9 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Photometric Test Report · 2018-05-24 · Flux(lm) Zonal Lumen Requiremen t(0°-90°) Field Angle(10%) Beam Angle(50%) Luminous Efficacy (lm/W) 40644 The samples were tested according

RAB Lighting Inc.

Xiao Xiang,15921313292,[email protected]

Prepared By

Prepared By Approved By

Wangzun Zhu Kevin Jia

Report Number

Test Date

Issue Date

2018/5/12

2018/5/12

The results contained in this report pertain only to the tested sample.

This report shall not be reproduced, except in full, without written approval of Deliver Co.,Ltd.

This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP.

Photometric Test Report

Relevant Standards

RANSI C82.77:2014

RIES LM-79-2008

Prepared For

Room 6A33, No.1388, Wuzhong road,Shanghai ,China

DLF1805109

DLF20180512001-3a

Deliver Co., Ltd.

Block 11, 78 Keling Road, SSTP, Suzhou, China

0512-66801950,[email protected]

Project Number

Doc No.: DLFLAB-ZY-01-28

Version:1.0 Page 1 of 16

Page 2: Photometric Test Report · 2018-05-24 · Flux(lm) Zonal Lumen Requiremen t(0°-90°) Field Angle(10%) Beam Angle(50%) Luminous Efficacy (lm/W) 40644 The samples were tested according

DLC Technical Requirements v4.3

RequirementsTest

value

Results

(Fail/Pass)

1000 40644 P

≥85% 100.00% P

120 126.6 P

5700 5007 P

65 72.4 P

0.873 0.966 P

25.00% 12.20% P

2.0  Test List

Test Item Test Date Sample No.

1 2018/5/12 C1

2 2018/5/12 C1

3 2018/5/12 C1

Remark(If any)

1、This report shall not be used by the client to claim product endorsement by NVLAP,

NIST or any agency of the US government.

2、The results reported herein have been performed in accordance with the laboratory’s

terms of accreditation. This report shall not be reproduced except in full without the written

approval of the Laboratory. The results in this report apply to the test sample(s) mentioned

above at the time of the testing period only and are not to be used to indicate applicability

to other similar products. This report does not imply that the product(s) has met the criteria

for certification.

Integrating Sphere Test

Goniophotometer Test

THD and PF Test

FXLED300SFB33

FXLED300SFB33

FXLED300SFB33

Outdoor - Architectural Flood and Spot Luminaires

Test

IES LM-79-2008

IES LM-79-2008

IES LM-79-2008

IES LM-79-2008

CIE 13.3-1995

Lamp Output (lm)

ANSI C82.77:2014

ANSI C82.77:2014

Zonal Lumen Requirement

(0°-90°)

Alowable CCTs* (K)

Minimum CRI

Power Factor

Total Harmonic Distortion (A%)

Minimum Luminaire Efficacy

(lm/W)IES LM-79-2008

Model Number

1.0  Test Summary

Test MethodRequirement Category

Doc No.: DLFLAB-ZY-01-28

Version:1.0 Page 2 of 16

Page 3: Photometric Test Report · 2018-05-24 · Flux(lm) Zonal Lumen Requiremen t(0°-90°) Field Angle(10%) Beam Angle(50%) Luminous Efficacy (lm/W) 40644 The samples were tested according

3.0 Production Description

Luminaire Description:

Electrical Specification: 120V-277V,50/60HZ

Light source: LC040D_Gen2

Manufacturer Of Light Source: Samsung Electronics LED Business

Photos of Luminaire Characteristics

LUMCAT: FXLED300SFB33

LUMINAIRE: CAST FINNED METAL HOUSING, CAST DIFFUSE CIRCUIT BOARD

MOUNTING PLATE, 8 CIRCUIT BOARDS EACH WITH 1 LED, MOLDED SPECULAR

FINISHED PLASTIC REFLECTOR WITH 1 APERTURE AND 1 CLEAR PLASTIC

CONVEX INNER LENS WITH 3 INTEGRAL MOUNTING POSTS PER LED, CLEAR

GLASS LENS IN CAST BROWN PAINTED METAL LENS FRAME WITH VISOR.

LAMP: EIGHT WHITE MULTI-CHIP LIGHT EMITTING DIODES (LEDS), AIMED AT THE

HORIZON.

Doc No.: DLFLAB-ZY-01-28

Version:1.0 Page 3 of 16

Page 4: Photometric Test Report · 2018-05-24 · Flux(lm) Zonal Lumen Requiremen t(0°-90°) Field Angle(10%) Beam Angle(50%) Luminous Efficacy (lm/W) 40644 The samples were tested according

Sample ID. C1

Opreate time (Min.)Stabilization time

(Min.)45

The samples were tested according to the IES LM-79-2008.

Temperatur

e (°C)

Voltage

(Vac)

Frequency

(Hz)Current (A) Power (W) Power Factor

25.1 119.99 60 2.693 321.10 0.994

CCT (K) CRI (Ra) Duv

5007 72.4 2.9E-03

Photometric paramters were measured using an integrating sphere, a spectroradiometer and

software. The ambient temperature condition inside the sphere was maintained at 25º C ± 1º C.

The sample measurements were made using a spectroradiometer connected by a fiber optic cable

and detector through the detector port of the integrating sphere.

The voltage of an AC power supply (RMS voltage) or DC power supply (instantaneous voltage)

applied to the device under test shall be regulated to within ±0.2 percent under load.

The sample was measured using 4π geometry and operated at rated voltage and was stabilized

before measurement. Chromaticity coordinates, correlated color temperature and color rendering

index were calculated from the spectral radiant flux measurements taken at 1 nm intervals over the

range of 380 to 780 nm.

Test Conditions

Test Result

4.0 LM-79 Measurement and Test Results

Test Method

90

4.1 Integrating Sphere Test

Model No. FXLED300SFB33

Doc No.: DLFLAB-ZY-01-28

Version:1.0 Page 4 of 16

Page 5: Photometric Test Report · 2018-05-24 · Flux(lm) Zonal Lumen Requiremen t(0°-90°) Field Angle(10%) Beam Angle(50%) Luminous Efficacy (lm/W) 40644 The samples were tested according

4.1 Integrating Sphere Test

Spectroradiometric Parameters

Doc No.: DLFLAB-ZY-01-28

Version:1.0 Page 5 of 16

Page 6: Photometric Test Report · 2018-05-24 · Flux(lm) Zonal Lumen Requiremen t(0°-90°) Field Angle(10%) Beam Angle(50%) Luminous Efficacy (lm/W) 40644 The samples were tested according

Sample ID.

Opreate time (Min.) Stabilization time (Min.) 45

Voltage

(Vac)

Frequency

(Hz)Current (A) Power (W)

Power

FactorOrientation

119.94 60 2.696 321.14 0.993 Light Down

Horizontal

Spread

Vertical

Spread

Horizontal

Spread

Vertical

Spread

100.00% 42.8 39.0 25.4 21.3 126.6

C1

Temperature

(°C)

25.1

Test Result

The ambient temperature shall be maintained at 25° C ± 1° C, measured at a point not more than 1

m from the sample and at the same height as the sample.

The voltage of an AC power supply (RMS voltage)or DC power supply (instantaneous voltage)

applied to the device under test shall be regulated to within ±0.2 percent under load.

Flux(lm)

Zonal

Lumen

Requiremen

t(0°-90°)

Field Angle(10%) Beam Angle(50%) Luminous

Efficacy

(lm/W)

40644

The samples were tested according to the IES LM-79-2008.

Photometric paramters were measured using a type C goniophotometer and software.

4.0 LM-79 Measurement and Test Results

4.3 Goniophotometer Test

Model No. FXLED300SFB33

90

Test Method

Test Conditions

The samples were operated at rated voltage and was stabilized before measurement. Luminous

flux, luminaire efficacy, zonal lumen were calculated from the software taken at 0.5o vertical intervals

and 10o horizontal intervals.

Doc No.: DLFLAB-ZY-01-28

Version:1.0 Page 6 of 16

Page 7: Photometric Test Report · 2018-05-24 · Flux(lm) Zonal Lumen Requiremen t(0°-90°) Field Angle(10%) Beam Angle(50%) Luminous Efficacy (lm/W) 40644 The samples were tested according

Light Distrubtion Curve

Isolux Plot

4.3 Goniophotometer Test

Doc No.: DLFLAB-ZY-01-28

Version:1.0 Page 7 of 16

Page 8: Photometric Test Report · 2018-05-24 · Flux(lm) Zonal Lumen Requiremen t(0°-90°) Field Angle(10%) Beam Angle(50%) Luminous Efficacy (lm/W) 40644 The samples were tested according

Luminous Intensity Distribution (cd)

4.3 Goniophotometer Test

Doc No.: DLFLAB-ZY-01-28

Version:1.0 Page 8 of 16

Page 9: Photometric Test Report · 2018-05-24 · Flux(lm) Zonal Lumen Requiremen t(0°-90°) Field Angle(10%) Beam Angle(50%) Luminous Efficacy (lm/W) 40644 The samples were tested according

ZONAL LUMEN SUMMARY

Zonal (lm) Total (lm) Percent

14764.86 0 - 10 14764.86 36.33%

17742.78 0 - 20 32507.64 79.98%

5460.84 0 - 30 37968.48 93.42%

1844.42 0 - 40 39812.89 97.96%

537.06 0 - 50 40349.96 99.28%

225.46 0 - 60 40575.41 99.83%

54.13 0 - 70 40629.54 99.96%

12.27 0 - 80 40641.81 99.99%

2.15 0 - 90 40643.96 100.00%

0.00 0 - 100 40643.96 100.00%

0.00 0 - 110 40643.96 100.00%

0.00 0 - 120 40643.96 100.00%

0.00 0 - 130 40643.96 100.00%

0.00 0 - 140 40643.96 100.00%

0.00 0 - 150 40643.96 100.00%

0.00 0 - 160 40643.96 100.00%

0.00 0 - 170 40643.96 100.00%

0.00 0 - 180 40643.96 100.00%

140 - 150

150 - 160

160 - 170

170 - 180

90 - 100

100 - 110

110 - 120

120 - 130

130 - 140

40 - 50

50 - 60

60 - 70

70 - 80

80 - 90

4.3 Goniophotometer Test

0 - 10

10 - 20

20 - 30

30 - 40

Doc No.: DLFLAB-ZY-01-28

Version:1.0 Page 9 of 16

Page 10: Photometric Test Report · 2018-05-24 · Flux(lm) Zonal Lumen Requiremen t(0°-90°) Field Angle(10%) Beam Angle(50%) Luminous Efficacy (lm/W) 40644 The samples were tested according

4.3 Goniophotometer Test

Axial Candela

DEG. HOR. DEG. VERT.

90 0.16 90 0.17

85 1.97 85 0.2

75 9.08 75 8.22

65 39.67 65 27.39

55 227.6 55 379.81

47.5 488.26 47.5 821.68

42.5 753.31 42.5 819.66

37.5 1709.59 37.5 1551.96

33 3783.49 33 4650.02

29 6219.9 29 7883.13

25.5 9240.05 25.5 9973.89

22.5 13097.79 22.5 15992.74

19.5 21369.93 19.5 38953

17 36357.48 17 62092.602

15 57846.711 15 77894.922

13 82984.859 13 100989.703

11 105625.398 11 124088.602

9 129628.398 9 155979.703

7 149657.406 7 182005

5 168310.203 5 194338

3 186066.797 3 203203.094

1 196565.5 1 202627.094

0 199854.797 0 199854.797

-1 199040.5 -1 193579.594

-3 193981.094 -3 177151.797

-5 182256.094 -5 150383.094

-7 168597.906 -7 121353.703

-9 149146.906 -9 95866.531

-11 131496.703 -11 75537.133

-13 107769.5 -13 58612.199

-15 85664.938 -15 38182.738

-17 61040.84 -17 22891.66

-19.5 37993.488 -19.5 13076.75

-22.5 21114.74 -22.5 9101.76

-25.5 11996.87 -25.5 7359.72

-29 7417.25 -29 4116.81

-33 4715.02 -33 1635.08

-37.5 2564.82 -37.5 986.41

-42.5 852.08 -42.5 658.97

-47.5 522.51 -47.5 409.73

-55 265.06 -55 138.21

-65 39.18 -65 31.33

-75 10.67 -75 7.91

-85 3.43 -85 2.56

-90 0.191 -90 0.2

Doc No.: DLFLAB-ZY-01-28

Version:1.0 Page 10 of 16

Page 11: Photometric Test Report · 2018-05-24 · Flux(lm) Zonal Lumen Requiremen t(0°-90°) Field Angle(10%) Beam Angle(50%) Luminous Efficacy (lm/W) 40644 The samples were tested according

4.3 Goniophotometer Test

Characteristics

NEMA Type 3 H x 3 V

Maximum Candela 203203.094

Maximum Candela Angle 0 H 3 V

Horizontal Beam Angle (50%) 25.3

Vertical Beam Angle (50%) 21.5

Horizontal Field Angle (10%) 43

Vertical Field Angle (10%) 39.6

Lumens Per Lamp N.A. (absolute)

Total Lamp Lumens N.A. (absolute)

Beam Lumens 19188

Beam Efficiency N.A.

Field Lumens 33533

Field Efficiency N.A.

Spill Lumens 7111

Luminaire Lumens 40644

Total Efficiency N.A.

Total Luminaire Watts 321.142

Ballast Factor 1

ISOCANDELA CURVES

Doc No.: DLFLAB-ZY-01-28

Version:1.0 Page 11 of 16

Page 12: Photometric Test Report · 2018-05-24 · Flux(lm) Zonal Lumen Requiremen t(0°-90°) Field Angle(10%) Beam Angle(50%) Luminous Efficacy (lm/W) 40644 The samples were tested according

Axial Candela0 1 3 5 7 9 11 13 15 17 19.5 22.5 25.5 29 33 37.5 42.5 47.5 55 65 75 85 90

90 0.17 0.169 0.166 0.163 0.161 0.158 0.155 0.153 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.153 0.16 0.16 0.1685 0.2 0.198 0.194 0.19 0.186 0.182 0.178 0.174 0.17 0.172 0.173 0.172 0.17 0.17 0.172 0.17 0.165 0.168 0.165 0.179 0.16 0.167 0.1675 8.22 8.17 8.069 7.968 7.59 7.316 7.005 6.658 6.387 6.27 6.146 6.002 5.78 5.278 4.815 4.421 3.929 3.594 2.977 2.038 0.757 0.197 0.1665 27.39 27.478 27.653 27.812 28.001 28.223 28.491 28.897 29.568 30.358 31.229 31.302 30.935 30.838 30.017 24.963 20.381 14.121 7.73 4.583 2.664 0.305 0.1655 379.81 366.26 339.177 305.054 272.708 240.044 208.483 186.888 182.86 178.455 170.933 158.533 141.97 117.674 93.237 60.854 39.026 34.661 21.657 7.789 4.07 0.556 0.16

47.5 821.68 790.981 729.647 662.293 594.28 522.128 446.199 425.024 408.416 392.338 370.733 342.102 312.929 285.249 237.765 176.406 117.46 57.426 34.573 13.646 4.629 0.841 0.1642.5 819.66 813.116 800.048 773.104 747.399 717.437 687.131 663.345 631.812 597.147 560.529 520.063 470.457 414.745 351.832 305.474 204.419 117.751 37.839 18.832 5.145 1.036 0.1637.5 1551.96 1555.58 1539.75 1506.54 1465.83 1383.84 1306.21 1201.06 1073.81 984.967 895.954 769.023 691.595 625.272 540.335 467.676 353.021 191.083 49.624 22.393 5.384 1.24 0.1633 4650.02 4629.65 4471.22 4225 3893.4 3582.59 3273.13 2855.74 2485.82 2133.21 1730.51 1362.35 1045.97 831.261 720.653 672.419 513.109 279.632 76.83 27.151 5.783 1.349 0.1629 7883.13 7861.65 7738.77 7534.5 7206.61 6773.75 6258.23 5669.62 4983.2 4295.29 3493.52 2639.48 1793.58 1248.48 866.751 780.955 619.574 347.057 104.791 31.046 6.336 1.451 0.16

25.5 9973.89 10003.4 9909.2 9705.29 9433.73 9106.02 8636.57 7989.8 7202.76 6373.77 5288.42 4077.69 3004.67 1839.03 1092.42 825.954 663.663 383.073 123.82 32.769 6.893 1.534 0.1622.5 15992.7 16054.6 15655.5 15016.8 13973.8 12639.7 11210.9 10179 9248.2 8190.2 6826.38 5328.59 4035.06 2737.64 1500.91 860.038 683.455 402.849 138.82 34.164 7.279 1.621 0.1619.5 38953 * 37647.89 * 33217.194 * 28296.281 * 24100.507 *20024.5 17266.5 14817.2 12324.3 10273.8 8619.53 6614.92 4992.33 3478.02 1905.63 936.621 654.6 407.403 160.083 36.196 7.655 1.699 0.1617 62092.602 * 60721.736 * 55642.391 * 49039.218 * 41641.039 * 33762.113 * 26812.401 * 20391.454 *16425.4 13397.5 10023.4 7814.08 5738.17 4071.64 2362.64 1024.18 657.669 393.944 175.453 37.271 7.973 1.757 0.1615 77894.922 * 77191.743 * 73139.293 * 66966.535 * 58550.202 * 47091.228 * 38237.238 * 28754.113 * 21526.075 *16159.6 11731.3 8656.37 6451.84 4468.65 2682.38 1121.09 662.52 411.634 186.179 37.869 8.233 1.799 0.1613 100989.703 * 99655.115 * 93038.097 * 85928.283 * 77442.2 * 64749.081 * 51388.07 * 38464.264 * 27600.088 *19515.9 14013.6 9424.45 7130.9 4900.9 2945.69 1277.83 676.043 428.738 196.136 37.95 8.421 1.836 0.1611 124088.602 * 123257.57 * 116421.185 * 112145.378 * 97926.646 * 80991.629 * 65677.702 * 49928.129 * 34599.703 * 24166.803 *16019.4 10363.8 7734.08 5219.1 3215.99 1419.91 696.186 444.335 204.992 38.071 8.618 1.937 0.169 155979.703 * 152927.054 * 141645.743 * 131198.011 * 120575.169 * 102970.412 * 79771.064 * 60937.532 * 42765.107 * 28266.926 *17840.4 11340.8 8286.16 5524.52 3408.15 1537.55 714.619 458.645 212.942 38.261 8.78 1.943 0.167 182005 * 176522.86 * 162303.821 * 150463.366 * 136128.88 * 119367.291 * 96302.273 * 71171.917 * 51530.535 * 32487.765 *20208.1 12326.6 8760.17 5807.7 3546.08 1644.5 729.468 470.485 219.019 38.533 8.908 1.949 0.165 194338 * 189906.735 * 178715.614 * 163867.977 * 150396.013 * 128750.015 * 105977.572 * 80219.444 * 57507.911 * 36538.92 * 21503.803 *13059.9 9060.98 6035.08 3678.12 1687.67 743.399 479.798 223.528 38.856 9.112 1.955 0.163 203203.094 * 198476.523 * 187013.587 * 171531.629 * 154137.024 * 133956.211 * 108410.332 * 84989.162 * 60281.708 * 38547.108 * 21979.679 *13332.7 9232.75 6179.03 3761.9 1718.83 757.42 489.307 228.343 39.25 9.099 1.961 0.161 202627.094 * 199270.382 * 189115.113 * 170909.807 * 154219.807 * 133616.575 * 108130.511 * 85187.402 * 59730.571 * 37895.969 * 21838.319 *13310.9 9289.12 6238.01 3795.97 1723.91 754.682 488.609 227.848 39.53 9.086 1.97 0.160 199854.797 * 196565.5 * 186066.797 * 168310.203 * 149657.406 * 129628.398 * 105625.398 * 82984.859 * 57846.711 * 36357.48 * 21369.93 *13097.8 9240.05 6219.9 3783.49 1709.59 753.31 488.26 227.6 39.67 9.08 1.97 0.16-1 193579.594 * 190700.914 * 178681.904 * 165550.251 * 146820.381 * 126745.911 * 102669.857 * 79855.097 * 55642.162 * 35348.804 * 20735.364 *12854.3 9123.66 6154.69 3747.32 1691.25 754.165 489.503 226.835 39.715 9.059 1.969 0.16-3 177151.797 * 174279.909 * 165473.767 * 147060.681 * 133409.117 * 115464.891 * 92067.364 * 69252.534 * 48470.121 * 31521.854 *18760.1 12002.1 8754.99 5937 3618.71 1622.04 755.871 491.985 225.308 39.806 9.018 1.967 0.16-5 150383.094 * 150257.091 * 139805.159 * 128688.389 * 117369.405 * 96183.916 * 78445.695 * 57312.354 * 40498.446 * 26862.85 *16401.9 10951.9 8319.39 5655.07 3447.65 1529.96 737.334 483.249 218.396 39.655 8.977 1.964 0.16-7 121353.703 * 119795.793 * 113551.253 * 106158.331 * 93635.913 * 78369.291 * 61809.774 * 45904.615 * 32300.375 * 21661.443 *14649.8 9946.33 7807.02 5316.12 3235.71 1429.93 716.367 473.965 211.743 39.482 8.721 1.962 0.16-9 95866.531 * 95573.219 * 90512.447 * 83987.534 * 74195.015 * 61020.639 * 47973.308 * 35004.335 * 24606.231 *17447.6 12998.9 9285.18 7249.61 4938.9 3019.72 1275.8 692.361 460.701 203.431 39.189 8.54 1.96 0.16-11 75537.133 * 75001.24 * 70270.367 * 65582.22 * 56871.712 * 45799.566 * 34229.397 * 26025.946 *18734.8 14877.8 11154.7 8564.87 6579.57 4533.39 2721.53 1121.7 665.564 443.062 194.555 38.763 8.326 1.957 0.16-13 58612.199 * 57984.824 * 53705.75 * 47285.351 * 38220.046 * 31110.335 * 24409.759 *18740.7 15267 12407.8 9836.64 7804.16 5906.68 4082.44 2343.89 1028 644.32 422.888 185.401 38.577 8.078 1.863 0.16-15 38182.738 * 37765.932 * 34439.826 * 29790.841 * 25277.195 * 20729.38 *17165.4 14737.3 12478.3 10382.8 8734.11 6975.25 5200.38 3546.33 1944.83 980.201 633.587 400.336 175.322 38.368 7.839 1.83 0.16-17 22891.66 * 22741.145 * 20899.282 *18382.7 16503.4 14856.5 13186.7 11379.8 10131.7 9001.97 7680.37 6107.88 4527.03 3010.89 1624.11 928.153 648.834 376.847 164.978 37.433 7.54 1.794 0.16

-19.5 13076.8 13139.6 12718.4 12024 11265.3 10540.7 9881.81 9230.15 8421.35 7537.9 6457.91 4959.8 3662.49 2354.54 1337.69 903.407 673.18 381.592 150.979 35.672 7.178 1.744 0.16-22.5 9101.76 9119.23 9021.51 8822.32 8600.22 8291.05 7847.56 7265.52 6566.6 5815.45 4786.63 3621 2505.59 1604.44 1086.42 880.326 675.081 378.678 132.81 32.991 6.764 1.676 0.16-25.5 7359.72 7338.02 7168.4 6909.14 6523.93 6132.85 5660.03 5121.17 4486.96 3841.44 3132.97 2233.08 1618.09 1118.06 925.009 909.348 637.44 355.859 116.163 32.293 6.357 1.6 0.16-29 4116.81 4128.65 4023.96 3826.97 3528.94 3233.73 2929.33 2655.5 2292.93 1930.73 1633.49 1315.71 953.641 824.266 783.661 786.185 595.081 305.771 99.822 28.981 5.915 1.526 0.16-33 1635.08 1631.49 1604.61 1559.04 1489.46 1429.78 1371.65 1262.44 1151.04 1033.81 901.318 787.065 687.259 616.429 619.808 599.727 482.719 227.341 80.592 25.114 5.521 1.435 0.16

-37.5 986.41 977.103 950.088 919.367 889.944 849.718 809.033 768.334 723.415 678.136 634.139 571.214 517.898 458.078 419.249 406.948 288.5 156.747 49.463 21.403 5.311 1.338 0.16-42.5 658.97 652.496 639.568 612.938 589.833 569.596 556.734 547.517 526.842 491.866 444.046 406.913 372.232 324.027 263.65 230.619 160.774 95.635 40.51 16.595 4.94 1.127 0.16-47.5 409.73 409.433 408.841 398.953 388.837 375.518 359.528 344.553 328.809 312.933 293.409 263.127 229.925 200.444 171.145 130.663 85.613 49.847 31.779 10.208 4.336 0.926 0.16-55 138.21 138.199 138.178 134.712 131.46 127.208 121.612 116.449 112.818 108.384 101.025 90.508 75.723 60.086 48.335 39.394 36.736 31.073 18.887 6.286 3.902 0.637 0.16-65 31.33 31.289 31.206 30.834 30.53 30.207 29.893 29.003 28.065 27.539 27.149 26.086 26.106 25.011 21.675 18.411 13.246 9.276 6.053 4.254 2.582 0.364 0.16-75 7.91 7.853 7.738 7.624 7.453 7.3 7.135 6.958 6.798 6.655 6.463 6.19 5.875 5.568 5.371 5.077 4.587 4.152 3.579 2.366 1.184 0.211 0.16-85 2.56 2.523 2.448 2.373 2.298 2.223 2.148 2.009 1.918 1.845 1.753 1.638 1.518 1.355 1.189 1.034 0.818 0.69 0.568 0.375 0.203 0.17 0.16-90 0.2 0.199 0.198 0.197 0.195 0.194 0.193 0.191 0.19 0.189 0.187 0.185 0.183 0.181 0.18 0.18 0.18 0.178 0.173 0.17 0.17 0.163 0.16

Doc No.: DLFLAB-ZY-01-28

Version:1.0 Page 12 of 16

Page 13: Photometric Test Report · 2018-05-24 · Flux(lm) Zonal Lumen Requiremen t(0°-90°) Field Angle(10%) Beam Angle(50%) Luminous Efficacy (lm/W) 40644 The samples were tested according

LUMEN TABULATION 0 1 3 5 7 9 11 13 15 17 20 23 26 29 33 38 43 48 55 65 75 85 90 Total90

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 085

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 075

0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.2 0.2 0.2 0.2 0.2 0.1 0.1 0.1 0 0 065

0.6 1.2 1.1 1 0.9 0.8 0.7 0.6 0.6 0.7 0.8 0.8 0.8 0.7 0.6 0.5 0.3 0.3 0.2 0.1 0 055

1.4 2.6 2.4 2.1 1.9 1.7 1.5 1.4 1.4 1.6 1.7 1.5 1.6 1.5 1.2 0.9 0.5 0.4 0.2 0.1 0 047.5

1.2 2.4 2.3 2.2 2.1 1.9 1.8 1.7 1.6 1.8 2 1.8 1.8 1.7 1.5 1.2 0.7 0.5 0.2 0.1 0 042.5

1.8 3.6 3.6 3.5 3.4 3.2 3 2.8 2.5 2.9 3.1 2.7 2.7 2.6 2.4 2 1.2 0.7 0.3 0.1 0 037.5

4.3 8.5 8.3 7.9 7.4 6.9 6.2 5.4 4.8 5.1 4.9 3.9 3.6 3.3 3 2.6 1.6 1 0.3 0.1 0 033

7.6 15 15 14 14 13 12 10 8.9 9.3 8.7 6.3 5.2 4.1 3.5 3 1.9 1.2 0.4 0.1 0 029

9.5 19 19 18 18 17 16 14 13 14 13 9.4 7.5 5.3 3.8 3 1.9 1.3 0.4 0.1 0 025.5

12 24 23 22 21 19 18 16 15 16 15 11 9.3 6.5 4.1 2.8 1.8 1.2 0.4 0.1 0 022.5

25.11 * 48.95 * 45.57 * 40.95 * 36 31 26 22 19 20 19 14 12 8.7 5.1 3 1.8 1.3 0.5 0.1 0 019.5

38.36 * 74.35 * 68.96 * 61.72 * 53.30 * 44.23 * 35 28 22 21 19 14 12 8.8 5.2 2.7 1.5 1.1 0.4 0.1 0 017

42.59 * 83.35 * 78.76 * 72.10 * 63.19 * 52.91 * 42.25 * 32.54 * 25 22 18 13 11 8 4.8 2.3 1.2 0.9 0.4 0.1 0 015

54.43 * 106.35 *100.79 *93.34 * 82.93 * 70.54 * 57.07 * 43.51 * 31.93 * 28 22 15 12 8.8 5.3 2.5 1.3 0.9 0.4 0.1 0 013

68.57 * 134.32 *128.17 *118.77 *104.79 *88.88 * 72.54 * 55.56 * 39.94 * 34 26 17 13 9.4 5.8 2.8 1.3 1 0.4 0.1 0 011

85.26 * 166.60 *158.21 *146.45 *129.80 *109.36 *88.33 * 68.06 * 48.91 * 40.95 * 30 19 14 10 6.2 3 1.3 1 0.4 0.1 0 09

102.34 *197.78 *185.65 *171.33 *153.36 *130.59 *104.96 *80.36 * 57.99 * 47.69 * 35 21 15 10 6.6 3.2 1.4 1 0.4 0.1 0 07

113.96 *220.99 *207.56 *190.86 *170.83 *146.66 *119.04 *91.34 * 65.92 * 53.53 * 38 22 16 11 6.8 3.3 1.4 1.1 0.4 0.1 0 05

120.53 *234.76 *220.97 *202.52 *181.31 *155.92 *127.31 *98.58 * 71.09 * 57.31 * 40 23 16 11 7 3.4 1.4 1.1 0.4 0.1 0 03

122.94 *239.49 *225.75 *206.31 *184.23 *158.66 *130.00 *101.03 *72.63 * 58.41 * 41 23 16 12 7.1 3.5 1.4 1.1 0.4 0.1 0 01

60.99 * 118.95 *112.00 *102.25 *91.04 * 78.28 * 64.36 * 49.95 * 35.75 * 28.74 * 20 12 8.3 5.8 3.6 1.7 0.7 0.5 0.2 0 0 00

Doc No.: DLFLAB-ZY-01-28

Version:1.0 Page 13 of 16

Page 14: Photometric Test Report · 2018-05-24 · Flux(lm) Zonal Lumen Requiremen t(0°-90°) Field Angle(10%) Beam Angle(50%) Luminous Efficacy (lm/W) 40644 The samples were tested according

59.68 * 116.39 *109.69 *100.27 *89.00 * 76.47 * 62.87 * 48.61 * 34.71 * 27.92 * 20 11 8.2 5.8 3.6 1.7 0.7 0.5 0.2 0 0 0-1

112.72 *220.31 *207.37 *189.34 *168.48 *144.72 *118.01 *90.39 * 64.58 * 52.17 * 37 22 16 11 7 3.3 1.4 1.1 0.4 0.1 0 0-3

100.10 *196.26 *184.63 *169.80 *151.38 *129.04 *104.07 *78.80 * 56.41 * 45.91 * 33 20 15 11 6.7 3.2 1.4 1.1 0.4 0.1 0 0-5

83.34 * 164.21 *156.38 *145.49 *128.89 *108.60 *87.05 * 65.87 * 47.17 * 39 29 18 14 10 6.3 3 1.3 1 0.4 0.1 0 0-7

66.57 * 132.08 *126.86 *117.56 *103.76 *87.30 * 69.78 * 52.60 * 37.61 * 32 25 16 13 9.6 5.9 2.8 1.3 1 0.4 0.1 0 0-9

52.50 * 104.20 *100.08 *92.56 * 81.36 * 67.84 * 53.75 * 40.38 * 29 26 21 15 12 8.9 5.3 2.5 1.2 1 0.4 0.1 0 0-11

40.98 * 80.75 * 77.00 * 70.43 * 61.03 * 50.18 * 39.44 * 30 23 21 18 13 11 8.1 4.8 2.3 1.2 0.9 0.4 0.1 0 0-13

29.64 * 58.56 * 55.28 * 49.53 * 42.32 * 34.92 * 28 22 18 17 16 12 9.7 7.1 4.1 2.1 1.2 0.9 0.3 0.1 0 0-15

18.79 * 37.43 * 35.45 * 31.97 * 28 23 20 16 14 14 14 10 8.6 6.1 3.6 2 1.1 0.8 0.3 0.1 0 0-17

14 27 26 24 22 20 18 16 14 15 15 11 9.1 6.4 3.8 2.4 1.4 1 0.4 0.1 0 0-20

10 20 20 19 18 17 16 15 13 15 14 10 8.4 5.9 3.9 2.8 1.8 1.2 0.4 0.1 0 0-23

7.5 15 15 14 14 13 12 11 9.9 11 10 7.3 5.7 4.2 3.3 2.8 1.7 1.1 0.4 0.1 0 0-26

6.1 12 12 11 11 10 9.3 8.4 7.3 7.6 7.2 5.2 4.3 3.6 3.4 3.1 1.9 1.2 0.4 0.1 0 0-29

3.5 7.1 6.9 6.6 6.3 5.9 5.4 4.9 4.2 4.5 4.4 3.5 3.2 3.1 3.2 3.1 2 1.2 0.4 0.1 0 0-33

1.8 3.6 3.5 3.4 3.2 3.1 2.9 2.7 2.5 2.8 2.9 2.5 2.5 2.6 2.7 2.6 1.7 1 0.3 0.1 0 0-38

1.3 2.5 2.4 2.3 2.2 2.1 2 1.9 1.8 2 2.2 2 2 1.9 1.9 1.8 1.1 0.7 0.3 0.1 0 0-43

0.8 1.6 1.6 1.5 1.4 1.4 1.3 1.3 1.2 1.4 1.5 1.3 1.4 1.3 1.2 1 0.6 0.4 0.2 0.1 0 0-48

0.6 1.3 1.2 1.2 1.2 1.1 1.1 1 1 1.1 1.2 1.1 1.1 1 0.9 0.7 0.4 0.4 0.2 0.1 0 0-55

0.3 0.5 0.5 0.5 0.5 0.5 0.5 0.5 0.4 0.5 0.6 0.5 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0 0-65

0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.1 0.2 0.1 0.2 0.2 0.2 0.1 0.1 0.1 0.1 0 0 0-75

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0-85

0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0-90

Total 1484 2904 2749 2530 2253 1928 1577 1232 916 799 630 414 323 238 156 91 48.5 34.3 13.2 2.23 0.32 0.01 20322

Doc No.: DLFLAB-ZY-01-28

Version:1.0 Page 14 of 16

Page 15: Photometric Test Report · 2018-05-24 · Flux(lm) Zonal Lumen Requiremen t(0°-90°) Field Angle(10%) Beam Angle(50%) Luminous Efficacy (lm/W) 40644 The samples were tested according

Model No. Sample ID.

Temperature

(°C)

Voltage

(Vac)

Frequency

(Hz)Current (A) Power (W)

Power

FactorTHD

25.1 119.99 60 2.693 321.10 0.994 9.76%

25.1 276.97 60 1.175 314.50 0.966 12.20%

FXLED300SFB33 C1

5.0 THD and PF Test

Test Results

The ambient temperature condition was maintained at 25º C ± 1º C. The sample measurements

were made using a digital power meter and power supply. The sample was operated at rated

voltage and was stabilized before measurement. The total harmonic distortion were calculated.

Test Method

The samples were tested according to the ANSI C82.77:2002.

The total harmonic distortion shall be measured to the 40th order.

Doc No.: DLFLAB-ZY-01-28

Version:1.0 Page 15 of 16

Page 16: Photometric Test Report · 2018-05-24 · Flux(lm) Zonal Lumen Requiremen t(0°-90°) Field Angle(10%) Beam Angle(50%) Luminous Efficacy (lm/W) 40644 The samples were tested according

Equipment ID Last

Calibration

Calibration Due

DateDLF107 2017/12/28 2018/12/27

DLF108 2017/12/28 2018/12/27

DLF122 2017/12/28 2018/12/27

DLF116 2017/12/28 2018/12/27

DLF113 2017/12/28 2018/12/27

DLF112 2017/12/28 2018/12/27

DLF114 2017/12/28 2018/12/27

DLF101 2017/12/28 2018/12/27

DLF125 2017/12/28 2018/12/27

DLF104 2017/12/28 2018/12/27

DLF507 2017/12/28 2018/12/27

DLF102 2017/12/28 2018/12/27

DLF111 2017/12/28 2018/12/27

DLF119 2017/12/28 2018/12/27

DLF031 2017/12/28 2018/12/27

DLF022 2017/12/28 2018/12/27

DLF003 2017/12/28 2018/12/27

*************** End of Test Report******************

Temperature data logger

Digital power meter

Temperature & Humidity Datalogger

Goniophotometer

Standard Lamp

Standard Lamp Type: 76.58 V, 6.7875 A,

Tungsten, Omni-derectional

AC Power Source

DC Power Source

Power Meter

Temperature & Humidity Datalogger

Power Meter

Temperature & Humidity Datalogger

Temperature Recorder

6.0 Equipment Information

Measurement Standard Lamp

Standard Lamp Type: 220 V, 0.4720 A,

Tungsten, Omni-derectional

AC Power Source

Power Meter

Auxiliary Lamp

Test Equipment

Equipment Name

Integrating Sphere System

Doc No.: DLFLAB-ZY-01-28

Version:1.0 Page 16 of 16