Concorde Career College, Department of Surgical Technology. Physical Environment & Safety Standards. Objectives. Recognize and understand the designs of the OR suite Determine the physical components of the OR Learn OR furniture and their names and functions - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Physical Environment & Safety Standards

Concorde Career College, Department of Surgical Technology

1

Page 2: Physical Environment & Safety Standards

Recognize and understand the designs of the OR suite

Determine the physical components of the OR Learn OR furniture and their names and functions Review the type of air-handling system required

in the OR Indicate cleaning procedures Distinguish among the support services that work

with the OR Recognize the hazards in the OR Analyze the role of the ST in the protection of self

patients and others from the hazards of the OR

2

Page 3: Physical Environment & Safety Standards

The location of the OR in the hospital is made to be easily accessible to and from surgical patient support departments

It is located and designed in an area where traffic is limited and the general public does not have access

3

Page 4: Physical Environment & Safety Standards

4

HOTEL – ORs are arranged along a central corridor

SPECIALTY – variation of the racetrack or hotel

Page 5: Physical Environment & Safety Standards

RACETRACK – involves a series of ORs around a clean central core

5

Page 6: Physical Environment & Safety Standards

RESTRICTED Proper O.R. attire required Mask required

SEMI-RESTRICTED Proper O.R. attire required

UNRESTRICTED Street clothes allowed

Separated by walls, doors, and red lines

6

Page 7: Physical Environment & Safety Standards

Semirestricted areas

Restricted areas Scrub suit Hair cover Shoe covers

and/or mask may be required

Jewelry, cosmetics, artificial nails are restricted

7

Page 8: Physical Environment & Safety Standards

8

Semi-restricted

Unrestricted

Restricted

Page 9: Physical Environment & Safety Standards

9

Red Line = semi restricted and restricted

Green Line = Unrestricted

Page 10: Physical Environment & Safety Standards

10

Page 11: Physical Environment & Safety Standards

ELCTRICAL OUTLETS – 110/220, must be 5’ above the floor. Explosion proof, red outlets are connected to the emergency generator

SUCTIONS OUTLETS – each OR must have at least 2 suction outlets; one for the surgical team, one for anesthesia

GAS OUTLETS (color coded) – oxygen – green; nitrogen –nitrogen – blackblack, nitrous oxide – blue, air- yellow, carbon dioxide – grey; outlets--- walls, ceiling, or mobile tanks; emergency shut off valve in exterior hall

11

Page 12: Physical Environment & Safety Standards

12

Page 13: Physical Environment & Safety Standards

LIGHTS – regular overhead, OR spot lights VIEWING BOX – to view diagnostic images OPERATING TABLE – narrow, padded and

flexible, traditional beds are manual, modern is electrical, mobile; features: Break points or bendable – knee, waist, and

head Removable sections at the head and foot Height can be adjusted Wide base to prevent tipping Rails along side for attachments ▪ Other OR beds- cysto, fracture- radiolucent

13

Page 14: Physical Environment & Safety Standards

14

Page 15: Physical Environment & Safety Standards

CLOCKS AND TIMERS – wall mounted, easily readable face, and a sweeping second hand; additional timer

COMMUNCATION SYSTEM – telephone; intercom system for intra-department (room to room; front desk) and inter-department use (pathology, radiology) some are foot operated

COMPUTER TERMINAL – for the circulator to fill out intra-op record, lab reports, order supplies for the room

OTHER – closed circuit TV

15

Page 16: Physical Environment & Safety Standards

16

Page 17: Physical Environment & Safety Standards

17

Page 18: Physical Environment & Safety Standards
Page 19: Physical Environment & Safety Standards

19

MAYO STAND – usually spans across patient; holds immediate necessary instruments; two wheeled and can be used to set up gowns and gloves.

Page 20: Physical Environment & Safety Standards

20

KICKBUCKET – four wheeled stands very low to the floor; can be maneuvered by a foot; lined with biohazard bags; holds soiled counted

sponges; NOT FOR TRASH!

Page 21: Physical Environment & Safety Standards

21

RING STAND – four wheeled with one or two rings waist high; used to hold basins; basins hold case related sterile fluids

Page 22: Physical Environment & Safety Standards

Used for skin prep, urinary catheterization, medical handling, etc.

Page 23: Physical Environment & Safety Standards

23

SUCTION SETS – low wheel based stands which hold suction canisters; sterile tubing form the surgical field will be hooked up to this by the circulator; the suction sets is hooked up to a wall suction outlet

Page 24: Physical Environment & Safety Standards
Page 25: Physical Environment & Safety Standards
Page 26: Physical Environment & Safety Standards
Page 27: Physical Environment & Safety Standards
Page 28: Physical Environment & Safety Standards
Page 29: Physical Environment & Safety Standards
Page 30: Physical Environment & Safety Standards
Page 31: Physical Environment & Safety Standards
Page 32: Physical Environment & Safety Standards

Monitoring equipment

Supplies

32

Page 33: Physical Environment & Safety Standards
Page 34: Physical Environment & Safety Standards
Page 35: Physical Environment & Safety Standards
Page 36: Physical Environment & Safety Standards
Page 37: Physical Environment & Safety Standards

37

Page 38: Physical Environment & Safety Standards

LINEN HAMPER – holds soiled linensTRASH CONTAINER – may be 2 per

room; one lined with a clear trash bag for clean trash and one lined with a biohazard bag for contaminated trash; some facilities are equipped with a metal detector to find instruments that may have been discarded accidentally

38

Page 39: Physical Environment & Safety Standards

SMOOTH, POUROUS FREEEASY TO CLEANNON REFLECTIVEPLEASANT IN COLOR WATERPROOFFIREPROOFNONGLARE

39

Page 40: Physical Environment & Safety Standards

DOORS RECESS INTO WALL (if poss.)

DOORS SHOULD BE KEPT CLOSED

40

Page 41: Physical Environment & Safety Standards

Provide clean airRemove air-borne contaminates that

are produced in the roomRemove waste anesthesia – besides

scavenger line Remove toxic fumes and vaporsComfortable working environment

41

Page 42: Physical Environment & Safety Standards

Produces positive pressureUnidirectional flow of air20 air exchanges per hourFiltered by High-efficiency

Particulate Air (HEPA) FiltersAt least 20% of the air change per

hour be fresh outside air

42

Page 43: Physical Environment & Safety Standards

An air exchanger system pulls air from the outside of the OR and pushes stale air from inside the OR out at frequent intervals thus becoming the air exchanger system.

43

Page 44: Physical Environment & Safety Standards

TEMPERATURE – should be kept between 65 and 75°F

RELATIVE HUMIDITY - should be kept between 20-60%

44

Page 45: Physical Environment & Safety Standards

SAME DAY or DAY SURGERY – patient arrives here, changes clothes, awaits surgery

LABORATORY – perioperative lab values

RADIOLOGY – x-ray films, fluroscopePATHOLOGY – processing specimensENVIRONMENTAL SERVICES-

cleaning 45

Page 46: Physical Environment & Safety Standards

Within the surgical services department

Entrance to OR suite for patientsShould be shielded from noise and

views of the ORs IVs startedPreop interviews

46

Page 47: Physical Environment & Safety Standards

Patient is recovered from anesthesia and surgery

47

Page 48: Physical Environment & Safety Standards

Usually above or below surgical services, or adjacent

Decontamination of soiled instruments

Assembly of instrument sets Sterilization of instrumentation andDistribution of supplies

48

Page 49: Physical Environment & Safety Standards

ERGONOMICS

SLIPPERY FLOORS

STANDING STOOLS

CROWDED O.R.’S

49

Page 50: Physical Environment & Safety Standards

Physical Noise, ionizing radiation, electricity,

injury to body, fire, explosionBiologic

Laser/electrosurgical plume, pathogens, latex sensitivity, sharps injury

50

Page 51: Physical Environment & Safety Standards

Chemical Disinfecting agents, waste anesthetic

gas, vapors and fumes

51

Page 52: Physical Environment & Safety Standards

OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION- OSHA

AMERICAN SOCIETY FOR TESTING AND MATERIALS - ASTM

ASSOCIATION FOR THE ADVANCMENT OF MEDICAL INSTRUMENTATION – AAMI

NATIONAL FIRE PROTECTION AGENCY - NFPA

52

Page 53: Physical Environment & Safety Standards

SOURCES X-ray machines▪ Portable▪ Fluoroscope (C-ARM)

PROTECTION – Time, shielding, and distance ▪ Lead aprons▪ Lead gloves▪ Lead glasses▪ Thyroid shield▪ Radiation badge

53

Page 54: Physical Environment & Safety Standards

LASER Light Amplification by the Simulated

Emission of Radiation Laser plume

Found to contain DNA of HPVCO2 laser can cause corneal burns

54

Page 55: Physical Environment & Safety Standards

Nd: Yag laser can cause retina blindness

High filtration mask and appropriate goggles are worn to protect the OR team

55

Page 56: Physical Environment & Safety Standards

Fire Laser and Bovie burns

R.A.C.ER- rescue, A-alert, alarm, C-contain, E-

extinguish,evacuate

56

Page 57: Physical Environment & Safety Standards

57

Page 58: Physical Environment & Safety Standards

Ignition

Fuel

Oxygen

58

Ignition

Page 59: Physical Environment & Safety Standards

ESU

Laser

Fiber-Optic Beam

Static Electricity

59

Page 60: Physical Environment & Safety Standards

Class A – water

Class B- dry chemical

Class C- halon

60

Page 61: Physical Environment & Safety Standards

Protect the patient

Contain the fire

Move anesthesia machine

61

Page 62: Physical Environment & Safety Standards

Electrical current

Electrical burns

Static electricity

62

Page 63: Physical Environment & Safety Standards

SOURCES Any body fluid or any item contaminated

with body fluids

PROTECTION PPE

63

Page 64: Physical Environment & Safety Standards

Universal precautions Applies to blood, certain fluids that contain

blood Standard states that blood and all body

fluids should be treated as potentially infectious

PERSONAL PROTECTIVE EQUIPMENT – PPE▪ Gloves▪ Masks▪ Eye protection

64

Page 65: Physical Environment & Safety Standards

SHARPS Suture, hypodermic needles, blades,

bovie tips, sharp instruments

CAUSES▪ Loading and passing suture, unsecured

sharps on field, recapping needles, catching falling items, poor sharp container management

65

Page 66: Physical Environment & Safety Standards

PREVENTION▪ Assume responsibility for you own safety▪ PPE▪ Never losing track of a sharp▪ Secure needles ▪ Leaving needles in package until use▪ Secured in a needle holder▪ Placed properly in needle board

66

Page 67: Physical Environment & Safety Standards

MANAGEMENT Postexposure prophylaxis –PEP

▪ Prophylaxis- prevention of a disease or condition

▪ Antibiosis- making the environment hostile to an organism

67

Page 68: Physical Environment & Safety Standards

68

Page 69: Physical Environment & Safety Standards

Smoke from burning tissue

Precautions

▪ High volume smoke evacuator

▪ Laser face masks

69

Page 70: Physical Environment & Safety Standards

Patient and personnel allergies

Latex free cart Patients with Spina Bifida are high risk

70

Page 71: Physical Environment & Safety Standards

71

Page 72: Physical Environment & Safety Standards

Polymethyl Methacrylate (PMMA) Bone Cement

Formalin: preservative for specimens in pathology

Glutaraldehyde (Cidex): liquid disinfectant and sterilizing agent

72

Page 73: Physical Environment & Safety Standards

73

Page 74: Physical Environment & Safety Standards

74

Page 75: Physical Environment & Safety Standards

75

Page 76: Physical Environment & Safety Standards

Page 91 Table 5-1

76