pictus b - kampakampa.co.tz/web/products/b50bd039d429e6ed375481c097c7403...specifications pictus b...

4
Pictus B The semi-automated analyzer for all laboratories Diatron Clinical Chemistry Quality without Compromise

Upload: others

Post on 23-Jan-2021

25 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: Pictus B - KaMpakampa.co.tz/web/products/b50bd039d429e6ed375481c097c7403...Specifications Pictus B We are at your service any time. Diatron reserves the right to change any of the

Pictus BThe semi-automated analyzer

for all laboratories

Diatron Clinical Chemistry • Quality without Compromise

Page 2: Pictus B - KaMpakampa.co.tz/web/products/b50bd039d429e6ed375481c097c7403...Specifications Pictus B We are at your service any time. Diatron reserves the right to change any of the

Pictus B analyzer meets the needs of small laboratories having not only a low sample volume but also require a cost effective and reliable system. With a built-in thermal printer and simple operation it can be used to run a number of manual clinical chemistry and coagulation tests (in a cuvette). It is an open system but for optimal performance the Diatron range of reagents should be used.

Analyzer Overview

Pictus B

Page 3: Pictus B - KaMpakampa.co.tz/web/products/b50bd039d429e6ed375481c097c7403...Specifications Pictus B We are at your service any time. Diatron reserves the right to change any of the

Key features and benefits

Fast, Flexible and Robust – the Pictus B provides reliable results.

Dual sampling modes: flow through-cell or standard and semi-micro cuvettes.

Multiple measurement options: Kinetic, 2 point kinetic & end point monochromatic or bichromatic.

User friendly with internal printer and simple operation through on-board keypad. It is also possible to use an optional PC keyboard.

High quality optical system with 9 filter positions with wide absorbance reading range.

Test options include photometry, turbidimetry and coagulation measurements.

Page 4: Pictus B - KaMpakampa.co.tz/web/products/b50bd039d429e6ed375481c097c7403...Specifications Pictus B We are at your service any time. Diatron reserves the right to change any of the

Specifications Pictus B

We are at your service any time.Diatron reserves the right to change any of the specifications without prior notice.Version Nr. PB131010V3

www.diatron.com

Optical system

• Light source: Quartz-halogen lamp, 6VDC, 10W

• Photometric range: -0,5 to 4 ABS

• Detector: Photodiode (320-11000nm)

• Wavelength range: automatic selection from a filter wheel of up to 9 filter positions

• Standard interferential filters: 340, 405, 450, 505, 550, 620 and 750 nm, plus 2 empty positions for optional filters

Blanks

• Automatic zero setting

• Water blanking

• Reagent blanking

Cuvette System

• Dual-cuvette system: selectable between 30 µL metallic flow cell with quartz windows OR

• standard 10 x10 mm holder for macro or semi-micro cuvettes

• Temperature control: automatic cooling/heating system using Peltier-element

• Temperature setting between: 25°C to 37°C

• Aspirator system: built-in peristaltic pump driven by stepper motor with volume calibration; reversible for sample recovery

• Reaction volume: selectable between 100 to 1000 µL per test

• Carry over: less than 2% for sipping volume 400 µL or more

Methods

• Max. 200 methods in memory, protected with built-in battery

Patients In Memory

• Max. 200 patients in memory (name, age, gender) with 10 test/patient

Measurement Procedures

• Kinetics, with linearity check

• Kinetics, with linearity check and blanking

• Two point kinetics, with or without reagent blank

• End point monochromatic or bichromatic, with or without reagent blank

• Coagulation

Measuring Time

• Programmable between 1 to 600 seconds for end-point methods and 2 to 600 for kinetics

Delay Time

• Programmable between 1 to 600 seconds

Calibration

• Factor, one-point, two-points and multi-points

• Automatic on 1 standard (linear mode)

• Automatic for up to 10 standards (non-linear mode)

Quality Control

• High/Low flags• On board statistical analysis and

Levey-Jennings plots• 5 control sets, 10 methods for control and 50

results for method: capacity of 2500 control values in memory

Operator Interface

• Membrane keypad with 25 buttons for function and numeric entries

• Graphic LCD, 240x128dot, 40x16 characters with backlight

• PC Keyboard (optional)

Printer

• Thermal graphic, 384 dots, 27 characters per inch

• Fast, quiet and heavy duty

Interface

• USB-B interface connector for PC connection• PS2 port for external keyboard• RS 232 Port for external printer or

PC text capture

Power Requirements

• 100-240 VAC 50/60 Hz,150W, earth grounded

Dimensions

• Size (Width x Depth x Height): 34 cm x 44 cm x 16 cm (13,4 in x 17,3 in x 6,3 in)

• Weight: 6 kg (13,2 lbs)

Your distributor