pike catalogue
DESCRIPTION
PIKE CatalogueTRANSCRIPT
WWW.PIKETECH.COM
C O M P R E H E N S I V E C A T A L O G O F
FTIR and UV-Vis Accessories and Supplies
MIRacle™The Most Universal ATR
A unique enterprise specializing in the imaginative
design and creation of excellent spectroscopic accessories,
providing high quality solutions to all customers.
We are PIKE Technologies, an innovative company growing consistently over our20 years and focused upon serving customers with their FTIR and spectroscopyapplications. We are always looking for new ways to help make your spectroscopysampling easier and more effective. We think you will see in our new products introduced each year that you, our customers, have helped us to achieve this goal.
If you do not see what you need in this catalog, please contact us. Your inputmay become one of our product offerings in the future. We look forward to serving you with our products and support.
6125 Cottonwood DriveMadison, WI 53719
(608) 274-2721(608) 274-0103 (FAX)
WWW. P I K E T E CH . COM
The PIKE Technologies team looksforward to helping you with our spectroscopy sampling accessoriesand thanks you for your business.
FTIR INSTRUMENT CODE XX
ABB Bomem FTLA2000-100 (Arid Zone) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 Michelson 100, MB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 MB 3000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Analect/Hamilton Sundstrand Diamond 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Bruker Optics IFS™, Vector™, Equinox™ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Tensor™, Vertex™ with recognition (Quick-Lock) . . . . . . . . . . . . . . . . . . . . . . . . 51
Buck Scientific M500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Digilab/Bio-Rad/Varian/Agilent Excalibur™, Scimitar™, FTS, 600-IR Series Cary 600/6000 Series . . . . . . . . . . . . 10 Excalibur, Scimitar, 600-IR Series Cary 600/6000 Series with recognition . . . . . 13
Horiba 7000 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Interspectrum Interspec 200-X . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Jasco 300/600 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 400. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 4000/6000 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 4000/6000 Series with recognition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
JEOL Winspec™ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Lumex InfraLUM® FT-02, FT-08 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Midac M Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
ORIEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
PerkinElmer 1700 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Spectrum™ GX, 2000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 Spectrum BX/RX, 1600, Paragon 1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Spectrum ONE, 65, 100, 400, FRONTIER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 Spectrum TWO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Shimadzu 8300, 8400 Series, IRPrestige, IRAffinity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 IRPrestige, IRAffinity with recognition (QuickStart) . . . . . . . . . . . . . . . . . . . . . . 16
Thermo Fisher Scientific/Nicolet/Mattson Infinity, Galaxy, RS Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Genesys™, Satellite, IR 300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Impact™ 400, Magna-IR™, Protégé™, 500/700 Series, Avatar™, Nexus™, Nicolet™ Series, Nicolet iS™10, Nicolet iS™50 . . . . . . . . . . . . . . . . . . . 40 Nicolet iS™5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Please contact PIKE for UV-Vis instrument codes
Sampling Kits – If You Don’t Know Where to Start
Products Overview .......................................................................................... 1
Standard Transmission Sampling Kit (STS)...................................................... 2
Comprehensive Transmission Sampling Kit (CTS) ........................................... 3
Educational Transmission Sampling Kit (ETS)................................................. 4
Valu-Line Kit .................................................................................................... 5
Ultima Sampling Kit ........................................................................................ 6
Pages 1–6
Attenuated Total Reflectance – Liquids, Solids and In-Between
Products Overview .......................................................................................... 7
MIRacle – Fast and Easy IR Sampling.............................................................. 8
GladiATR – Highest Performance Diamond ATR .............................................. 12
GladiATR Vision – Diamond ATR with Sample View ........................................ 14
Dedicated GladiATR and GladiATR Vision Sampling Tools – More Options to Address Your Specific Application Requirements ............ 16
Multiple Reflection HATR – Maximum Sensitivity and Highly Versatile FTIR Sampling........................ 17
ATRMax II Variable Angle Horizontal ATR Accessory – HATR for Inquisitive Minds ....................................................................... 21
VeeMAX III with ATR – Variable Angle, Single Reflection ATR for Depth Profiling Studies............. 24
JetStream ATR Accessory – Measurements of Liquids under Varying Conditions ................................ 27
Classic VATR – Variable Angle ATR for Analysis of Solids, Films and Coatings ................. 28
Theory and Applications ................................................................................. 29
Pages 7–32
Diffuse Reflectance – From Powders to Plastic Bumpers
Products Overview .......................................................................................... 33
EasiDiff – Workhorse Diffuse Reflectance Accessory......................................... 34
DiffusIR – Research Grade Diffuse Reflectance Accessory ................................ 35
UpIR – Upward Looking Diffuse Reflectance Accessory.................................... 37
AutoDiff – Automated Diffuse Reflectance Sampling....................................... 38
X, Y Autosampler – Transmission and Reflectance Automated Sampling in Microplate Format ................................................................. 39
Sample Preparation and Loading Kit – The Easiest Way to Work With Powder Samples ....................................... 40
Abrasion Sampling Kit..................................................................................... 40
Theory and Applications ................................................................................. 41
Pages 33–42
TABLE OF CONTENTS
01_Sampling 12-12-12_01_Sampling 12/13/12 1:11 PM Page 1
PIK
ET
EC
HN
OL
OG
IES
WW
W.
PIK
ET
EC
H.
CO
M6
08
-27
4-2
72
1
Microsampling Products – From Microns to Millimeters
Products Overview .......................................................................................... 71
µMAX – Sample Compartment Microscope for FTIR ........................................ 72
Compact Transmission/Reflection S84 Microscope Heat Stage – High Temp Measurements under Vacuum or Controlled Gas Flow ........... 75
Microsampling Tools – Compression Cells and Sample Manipulation ............ 76
Micro Diamond Cell – For Compressing and Holding Samples for Microanalysis... 77
Beam Condensers – 4X and 6X Versions for FTIR ........................................... 78
Pages 71–80
TABLE OF CONTENTS
Polarization – For Oriented Samples and Research Applications
Products Overview .......................................................................................... 53
Polarizers – Manual and Automated Versions for Molecular Spectroscopy ..... 54
Theory and Applications ................................................................................. 55
Pages 53–56
Integrating Spheres – Reflectance From All Perspectives
Products Overview .......................................................................................... 57
Mid-IR IntegratIR – Integrating Sphere............................................................ 58
NIR IntegratIR – Integrating Sphere ................................................................ 60
Introduction and Theory................................................................................. 62
Pages 57–64
Remote Sampling Accessories –Extending Your Sample Compartment
Products Overview .......................................................................................... 65
FlexIR – Hollow Waveguide Accessory for Remote Infrared Sampling ............. 66
FlexIR – NIR Fiber Optic Accessory for Fast and Remote Sample Identification ...... 68
Heated Liquid Sample Holder – Characterization of Liquids at Controlled Temperatures........................... 69
Pages 65–70
Specular Reflectance – Thin Films and More
Products Overview .......................................................................................... 43
VeeMAX III – The Ultimate Variable Angle Specular Reflectance Accessory ....... 44
30Spec and 45Spec – Specular Reflectance for Thick Films............................. 46
80Spec – Grazing Angle Specular Reflectance for Thin Films........................... 47
AGA – Advanced Grazing Angle Specular Reflectance for Thin Films with Precise Spot Control ............................................................................ 48
10Spec – Near-normal Sample Reflectivity Measurements .............................. 49
Absolute Reflectance Accessory – Measure Absolute Sample Reflectivity ........ 50
Theory and Applications ................................................................................. 51
Pages 43–52
01_Sampling 12-12-12_01_Sampling 12/13/12 1:11 PM Page 2
Transmission Sampling – Automated & Manual Technologies
Products Overview .......................................................................................... 81
Transmission Multi-SamplIR – Automated In-Sample Compartment Accessory .... 82
RotatIR – Automated Rotating Sample Stage................................................... 83
Automated Horizontal Transmission Accessories – For Films or Pellets......... 84
X, Y Autosampler – Transmission and Reflection, Automated Sampling in Microplate Format ....... 85
Liquid Samples
Press-On Demountable Cell – For Viscous Liquids and Mulls ......................... 86
Demountable Liquid Cells – For Versatile Pathlength Liquid Sampling.......... 87
Super-Sealed Liquid Cells – For Precision, Fixed Pathlength Liquid Sampling.... 88
Long-Path Quartz Liquid Cells – For Analysis of Hydrocarbon Content and Related Measurements................ 89
Falcon Mid-IR Transmission Accessory – For Precise Temperature Control of Demountable Liquid Cells ................ 90
Falcon NIR Transmission Accessory – Quantitative and Qualitative Analysis of Liquids under Precise Temperature Control............................ 92
Cryostat190 – Ultralow Temperature Accessory for Liquid and Solid Transmission Sampling ............................................................................. 93
Solid Samples
Cryostat190 – Ultralow Temperature Accessory for Liquid and Solid Transmission Sampling ............................................................................. 93
Heated Solid Transmission Accessory – Measurements of Optical Components and Polymers .............................. 94
Bolt Press & Hydraulic Die – Low-Cost Pellet Preparation .............................. 95
Hand Press – For Making Smaller Pellets ........................................................ 95
Evacuable Pellet Press – For Preparation of High Quality Pellets .................. 96
Heated Platens Accessory – For Making Thin Films of Polymeric Samples for Transmission FTIR Analysis ................................................................. 97
CrushIR – Digital Hydraulic Press .................................................................... 98
Auto-CrushIR – Programmable Hydraulic Press............................................... 99
ShakIR and Super ShakIR – For Optimized Sample Mixing ............................. 100
Sample Preparation Accessories – For Solid Material Analysis ....................... 101
Optical and Sampling Components, Polishing Kits
Sample Holders – For Transmission FTIR Analysis of Pellets and Films .......... 102
Disks, Windows and Powders – For Transmission FTIR Analysis of Solid and Liquid Samples ..................... 103
Crystal Polishing Kit – Extending the Life of IR Transparent Windows............ 106
Gas Samples
Short-Path Gas Cells – For Samples with Higher Vapor Phase Concentration..... 107
Heated Gas Flow Cell – For Streaming Gas Analysis ........................................ 108
Long-Path Gas Cells – For Measurement of Low Concentration Vapor Components ................... 109
Theory and Applications ................................................................................. 111
Pages 81–114
01_Sampling 12-12-12_01_Sampling 12/13/12 1:11 PM Page 3
PIK
ET
EC
HN
OL
OG
IES
WW
W.
PIK
ET
EC
H.
CO
M6
08
-27
4-2
72
1
TABLE OF CONTENTS
Special Applications
Products Overview .......................................................................................... 115
Vertical Wafer Accessory – For Analysis of Semiconductor Wafers.................. 116
MappIR and MAP300 – For Automated Analysis of Semiconductor Wafers .... 117
TGA/FTIR Accessory – Identification and Quantification of Evolved Gases from Thermogravimetric Analyzer ............................................................ 119
GC-FTIR Accessory – Combining GC Separation with Identification Power of FTIR ................... 121
External Sample Module – Extending Sampling Efficiency.............................. 122
PA301 and PA101 – Photoacoustic Accessory for Analysis of Difficult Samples and Depth Profiling ...................................................... 123
Semiconductor Applications – FTIR Sampling Techniques Overview .............. 125
Pages 115–126
Standards, Software and Databases
Products Overview .......................................................................................... 139
Reference Standards – For Calibrating FTIR Spectrometers ............................ 140
PIKECalc Software – For FTIR Sampling Computations ................................... 143
ATR Spectral Databases – Optimize Search Results for ATR Spectral Data ...... 144
Transmission Spectral Databases – High Quality Spectral Data for Optimized Search Results .......................... 145
Index
Catalog Index – Alphabetical........................................................................... 146
Catalog Index – Part Number.......................................................................... 149
Pages 139–145
UV-Vis Accessories
Products Overview .......................................................................................... 127
UV-Vis Cuvettes, Cells, Vials and Holders........................................................ 128
UV-Vis Polarizers – Manual and Automated Versions ..................................... 130
UV-Vis Spec – Slide Mounted Specular Reflectance Accessories ....................... 131
UV-VIS 85Spec – Specular Reflectance Accessory ............................................. 132
UV-Vis VeeMAX – Variable Angle Specular Reflectance Accessory.................... 133
Falcon UV-VIS – Precise Cell Temperature Control Accessory........................... 134
Peltier-Controlled Cuvette Holders for UV-Vis Spectrophotometers – Experiments Under Tightly Controlled Temperature Conditions ............... 135
Out-of-Compartment Microplate Reader – Plate Reading Option for UV-Vis Spectrophotometers .............................. 136
Automated XY, R-Theta and Y-rotation Stages for UV-Vis Spectrophotometers ..................................................................... 137
Pages 127–138
01_Sampling 12-12-12_01_Sampling 12/13/12 1:11 PM Page 4
Sampling KitsIf you are not sure where to start, check out these
PIKE Technologies sampling kits. You will immediately
find everything you need for the most basic FTIR
experiments, and you will be able to collect your
first spectrum in less than 30 minutes from the
time the kit arrives.
One of the goals of PIKE Technologies is to
make the life of an applications chemist easier. FTIR
spectroscopy can be confusing when it comes to
sampling techniques, sampling accessories and all
the little gadgets required to successfully prepare
the sample for analysis – especially if you want to
obtain good spectra. For this reason, the first few
pages of this catalog are fully dedicated to sampling
kits. We hope that this approach will give you a head
start and remove confusion when selecting accessories
for your applications, especially when you are a
first time user. The kits are carefully designed to
include all necessary components. They eliminate
guesswork and assure that you have everything you
need for immediate productivity.
Standard Transmission Sampling Kit Everything you need to run liquidand solid samples by transmissionIR spectroscopy
Page 2
Comprehensive Transmission Sampling Kit Complete gas, liquid and solid sampling
Page 3
Educational Transmission Sampling Kit An economical assembly of FTIR sampling tools for transmission sampling
Page 4
Valu-Line KitHigh performance set of modernFTIR accessories addressing all solid and liquid sampling needs
Page 5
Ultima Sampling Kit With the highest performance,single-reflection ATR and backupaccessories to do it all!
Page 6
01_Sampling 12-12-12_01_Sampling 12/13/12 1:12 PM Page 5
Standard Transmission Sampling Kit (STS) – Everything You Needto Run Liquid and Solid Samples by Transmission IR Spectroscopy
This general purpose kit contains tools and materials for liquidand solid sampling. A demountable cell (drilled and undrilledwindows with precision Teflon spacers, plus 2" x 3" standard cellholder) is provided for measurements of liquid samples. Viscousliquids can be measured directly as a thin film between the KBrwindows. The kit includes a hand operated press for the preparationof 7 mm KBr pellets. A mortar with pestle and Nujol™/Fluorolube®are provided for mull making – another popular method forpreparation of solid samples. In addition, the kit contains a set ofthe most popular sample holders including: universal holder forpolymer films, KBr pellet holder and PIKE disposable/storagecardboard cards for pellets and polymer films. For a completeproduct listing, please refer to the table below.
PIK
ET
EC
HN
OL
OG
IES
WW
W.
PIK
ET
EC
H.
CO
M6
08
-27
4-2
72
1
2
FE AT U R E S O F TH E S TA N DA R D
TR A N S M I S S I O N SA M P L I N G K I T
• Complete kit for transmission FTIR sampling
• Make KBr pellets and mulls for solid samples
• Run liquid samples for qualitative and quantitative analysis
OR D E R I N G IN F O R M AT I O N
PA R T N U M B E R D E S C R I P T I O N
162-1000 Standard Transmission Sampling Kit (STS) – Solids and LiquidsIncludes: Sample preparation tools, mull liquids, cells, windowsand cell holders required for preparation and analysis of solid and liquid samples
Included Parts and MaterialsPA R T N U M B E R D E S C R I P T I O N
160-8010 KBr Powder, 100 g
161-0510 Fluorolube, 1 oz
161-0500 Nujol, 1 oz
042-3035 Spatula – Spoon
042-3050 Spatula – Flat
161-5050 Mortar and Pestle, 50 mm
161-1027 PIKE Hand Press (for KBr Pellets)
161-1010 7 mm Die Set
161-1018 KBr Pellet Holder
161-6000 Finger Cots (12 pcs)
162-1100 Demountable Liquid Cell Assembly
160-1015 Window, KBr 32 x 3 mm, Drilled (6 ea.)
160-1010 Window, KBr 32 x 3 mm, Plain (6 ea.)
162-1290 Teflon® Spacers – Assortment
161-0521 Syringe, 2 mL (2 ea. in kit)
162-3610 Press-On Demountable Liquid Cell Holder for 32 mm Windows
162-5600 Universal Sample Holder*
162-5300 Magnetic Film Holder – for 13 mm pellets and film samples
162-5400 Film Sampling Card – 20 mm clear aperture, 10 each*
*Note: Cell holders marked “*” fit all standard slide mounts, but due to theirheight may not allow for a complete sample compartment door closure on somesmaller spectrometers. Please consult PIKE Technologies before placing an order.
01_Sampling 12-12-12_01_Sampling 12/13/12 1:12 PM Page 2
3
SA
MP
LIN
GK
IT
S–
IF
YO
UD
ON’T
KN
OW
WH
ERE
TO
START
Comprehensive Transmission Sampling Kit (CTS) – Complete Gas, Liquid and Solid Sampling
The CTS Kit includes a 100 mm long, 38 mm diameter gas cell, in addition to all the sample preparation and mounting toolsdescribed in the STS Kit on the previous page. The cell body ismade of Pyrex® glass and features straight-tube inlet and outletports with stopcocks. The gas cell comes with all necessary gaskets, two KBr windows and slide-mounted cell holder, and is designed for gas measurements at ambient temperature and normal atmospheric pressure.
OR D E R I N G IN F O R M AT I O N
PA R T N U M B E R D E S C R I P T I O N
162-2000 Comprehensive Transmission Sampling Kit (CTS) – Gases, Solids and LiquidsIncludes: Sample preparation tools, mull liquids, cells, windows and cell holders required for preparation and analysis of gas, solid and liquid samples
Included Parts and MaterialsPA R T N U M B E R D E S C R I P T I O N
160-8010 KBr Powder, 100 g
161-0510 Fluorolube, 1 oz
161-0500 Nujol, 1 oz
042-3035 Spatula – Spoon
042-3050 Spatula – Flat
161-5050 Mortar and Pestle, 50 mm
161-1027 PIKE Hand Press (for KBr Pellets)
161-1010 7 mm Die Set
161-1018 KBr Pellet Holder
161-6000 Finger Cots (12 ea.)
162-5300 Magnetic Film Holder – for 13 mm pellets and film samples
162-1100 Demountable Liquid Cell Assembly
160-1015 Window, KBr 32 x 3 mm, Drilled (6 ea.)
160-1010 Window, KBr 32 x 3 mm, Plain (6 ea.)
162-1290 Teflon® Spacers – Assortment
161-0521 Syringe, 2 mL (2 ea. in kit)
162-3610 Press-On Demountable Liquid Cell Holder for 32 mm Windows
162-5600 Universal Sample Holder*
162-2200 100 mm Gas Cell, 38 mm diameter
160-1320 Window, KBr 38 x 6 mm (2 ea. in kit)
162-5400 Film Sampling Card – 20 mm clear aperture, 10 each*
*Note: Cell holders marked “*” fit all standard slide mounts, but due to theirheight may not allow for a complete sample compartment door closure on somesmaller spectrometers. Please consult PIKE Technologies before placing an order.
F E AT U R E S O F TH E CO M P R E H E N S I V E
TR A N S M I S S I O N SA M P L I N G K I T
• Complete sampling kit for analysis of solids, liquids and gas samples by transmission
• Make KBr pellets and mulls for solid samples
• Run qualitative and quantitative analysis of liquid samples
• Identify and quantify gas samples
01_Sampling 12-12-12_01_Sampling 12/13/12 1:12 PM Page 3
Educational Transmission Sampling Kit (ETS) – An Economical Assembly of Sampling Tools
The Educational Sampling Kit contains all necessary tools for theanalysis of gas, liquid, and solid samples. It was designed as alow-cost alternative for busy teaching laboratories. The kit offers a100 mm x 25 mm gas cell with straight, septa protected tubes, BoltPress for making KBr pellets and a 35 mm mortar and pestle. Pleaserefer to the table below for the detailed list of all components.
PIK
ET
EC
HN
OL
OG
IES
WW
W.
PIK
ET
EC
H.
CO
M6
08
-27
4-2
72
1
4
OR D E R I N G IN F O R M AT I O N
PA R T N U M B E R D E S C R I P T I O N
162-3000 Educational Transmission Sampling Kit (ETS) – Gases, Solids and LiquidsIncludes: Sample preparation tools, mull liquids, cells, windows and cell holders required for preparation and analysis of gas, solid and liquid samples
Included Parts and MaterialsPA R T N U M B E R D E S C R I P T I O N
160-8010 KBr Powder, 100 g
162-1100 Demountable Liquid Cell Assembly
161-0510 Fluorolube, 1 oz
160-1015 Window, KBr 32 x 3 mm, Drilled (6 ea.)
161-0500 Nujol, 1 oz
160-1010 Window, KBr 32 x 3 mm, Plain (6 ea.)
042-3035 Spatula – Spoon
162-1290 Teflon® Spacers – Assortment
042-3050 Spatula – Flat
161-0521 Syringe, 2 mL (2 ea. in kit)
161-5035 Mortar and Pestle, 35 mm
162-3610 Press-On Demountable Liquid Cell Holder for 32 mm Windows
161-2500 Bolt Press (for KBr Pellets)
162-2100 100 mm Gas Cell, 25 mm diameter
161-2511 Wrench Set for Bolt Press (2 ea.)
160-1133 Window, KBr, 25 x 4 mm (2 ea. in kit)
161-6000 Finger Cots (12 ea.)
162-5300 Magnetic Film Holder – for 13 mm pellets and film samples
162-5400 Film Sampling Card – 20 mm clear aperture, 10 each*
*Note: Cell holders marked “*” fit all standard slide mounts, but due to their
height may not allow for a complete sample compartment door closure on some
smaller spectrometers. Please consult PIKE Technologies before placing an order.
F E AT U R E S O F TH E ED U C AT I O NA L
TR A N S M I S S I O N SA M P L I N G K I T
• Basic sampling kit for transmission FTIR sampling
• Perform qualitative and quantitative analysis
• Economical analysis of solids, liquids and gases
01_Sampling 12-12-12_01_Sampling 12/13/12 1:12 PM Page 4
5
SA
MP
LIN
GK
IT
S–
IF
YO
UD
ON’T
KN
OW
WH
ERE
TO
START
Valu-Line – High Performance Set of FTIR Accessories AddressingAll Solid and Liquid Sampling Needs
The number of available FTIR accessories is quite overwhelming.It is easy to be confused by multiple, often esoteric choices at typically exuberant prices. Sometimes, it is not easy to decidewhich accessory will do the job. An answer to this problem is PIKE Technologies’ Valu-Line Accessory Kit. This Kit, packaged in a durable and convenient storage case, combines the most oftenused and practical set of FTIR sampling accessories. It includesthe following components:
HATR – Horizontal ATRIs designed to analyze liquid and semi-liquid samples, pastes, gels,films, soft powders and multiple solid materials. This accessorycomes with trough and flat crystal plates to accommodate alltypes of samples. The HATR is carefully designed to provide excellent results with minimum effort. It can be easily placed in the sample compartment and locked into position on the sample compartment baseplate, or a standard slide holder.
EasiDiff – Diffuse Reflectance AccessoryIs an ideal accessory for the analysis of powders and intractablesolids. With a set of convenient tools for solid sample preparation,this compact, high performance accessory provides outstandingcollection efficiency.
30Spec – Specular Reflectance AccessoryIs a great accessory for the analysis of thin organic films depositedon reflective surfaces and a myriad of surface coatings and surfacetreatments. The 30Spec is slide-mounted and comes with a set ofthree masks which allow for the isolation of small, pre-determinedspots on larger samples, and the analysis of small samples.
Please refer to the appropriate section of this catalog for moredetail about these accessories.
F E AT U R E S O F TH E VA LU - L I N E S A M P L I N G K I T
• Combination of most widely used FTIR accessories including:– Horizontal ATR– Diffuse Reflectance – 30 Degree Specular Reflectance
• Full range of sampling options and applications
• Complete set of auxiliary sample preparation tools forimmediate productivity
• Pre-aligned, fixed-position optical designs offering reproducible, high quality data
• High performance accessories providing excellent sampling sensitivity
• Economical and logical addition to any FTIR spectrometer. Excellent starter kit for routine applications, research or teaching
OR D E R I N G IN F O R M AT I O N
PA R T N U M B E R D E S C R I P T I O N
050-10XX Valu-Line – FTIR Reflectance Accessories Kit Includes: HATR – combined trough and flat plate system, including 45º ZnSe crystals; trough plate, volatiles cover, powder press, flat plate and sample clampEasiDiff – Accessory with sampling tools, two micro, two macro sample cups, EasiPrep sample preparation kit, alignment mirror, pestle and mortar, KBr30Spec – Specular reflectance accessory with a set of three masks for control of the sampling spot size
Note: Select XX FTIR code from foldout on last page of this catalog. Add -GE, -KR, -SI or -AM to the part number to substitute the following HATR crystal plates:Germanium, KRS-5, Silicon or AMTIR.
01_Sampling 12-12-12_01_Sampling 12/13/12 1:12 PM Page 5
Ultima Sampling Kit – With the Highest Performance, Single-reflection ATR and Backup Accessories to Do it All
In recent years, single-reflection ATR measurements have becomequite popular for at least two main reasons – they further simplifysample preparation and also reduce the complexity of traditionalFTIR measurements. This is achieved through the reduction of thesampling area (smaller sample volume/size requirement), ease ofcleaning and the introduction of more rigid, diamond-protectedsampling interfaces, capable of withstanding higher pressures andharder samples. In many cases the single-reflection ATR hasbecome capable of analyzing a wide variety of samples – includingrigid solids and hard powders – which are difficult to achieve witha multi-reflection ATR. For these reasons, the single reflection ATRhas gained the reputation of being a universal sampling device.
This is true 80% of the time. The other 20% (especially whendealing with poor absorbers, some powders and films) still needto be analyzed by other methods. For this reason, PIKE designedan accessory kit built around the MIRacle – Single Reflection ATR,and also included basic diffuse reflectance and specularreflectance accessories. This combination offers one of the mostcomplete range of sampling devices used in FTIR and covers awide variety of sampling needs.The Ultima Sampling Kit containsthe following accessories:
MIRacle – Single Reflection ATRDesigned to analyze a wide variety of solid and liquid samples. Itoffers a number of unique features including: a universal samplingplate which accommodates liquids, solids and powders, small (1.8 mm) sampling interface making the analysis of small and/orawkward samples easy, and interchangeable sampling plates. Allthe above options allow for the best selection of an appropriate spectral range, and a configuration which matches the optical,physical and chemical properties of analyzed samples. Thepatented optical design of the accessory offers the highest optical throughput and sensitivity. The MIRacle is equipped with apressure clamp and purge attachments.
EasiDiff – Diffuse Reflectance AccessoryAn ideal product for the analysis of powders and intractablesolids. With a set of convenient tools for sample preparation, this compact, high performance accessory provides outstandingcollection efficiency.
30Spec – Specular Reflectance AccessoryA great accessory for the analysis of thin organic films depositedon reflective surfaces and a myriad of surface coatings and surfacetreatments. The 30Spec is slide-mounted and comes with a set ofthree masks which allow for the isolation of small, predeterminedspots on larger samples, and the analysis of small samples.
Please refer to the appropriate section of this catalog to reviewthe theory and detailed description of kit components.
PIK
ET
EC
HN
OL
OG
IES
WW
W.
PIK
ET
EC
H.
CO
M6
08
-27
4-2
72
1
6
FE AT U R E S O F TH E U LT I M A SA M P L I N G K I T
• Complete kit for ATR, diffuse reflectance, and specularreflectance
• High-performance accessories eliminate tedious pellet making
• Analysis of liquids, solids, powders, polymers, and thin film samples
OR D E R I N G IN F O R M AT I O N
PA R T N U M B E R D E S C R I P T I O N
050-20XX Ultima Sampling Kit with: MIRacle – Single-reflection ATR with ZnSe Crystal, Universal Configuration for solid and liquid analysis, and High Pressure ClampEasiDiff Accessory with Sampling Tools, two each micro and macro Sample Cups, EasiPrep Sample Preparation Kit,Alignment Mirror, Pestle and Mortar, and KBr 30Spec – Specular Reflectance Accessory with a set of threemasks for control of the sampling spot size
Notes: Select XX FTIR code from foldout on last page of this catalog. Add -DI, -GE or -SI, to the part number to substitute the following MIRacle crystal plates:Diamond/ZnSe, Germanium or Si.
01_Sampling 12-12-12_01_Sampling 12/13/12 1:12 PM Page 6
Attenuated Total ReflectanceATR products successfully replace constant path
transmission cells and salt plates used for analysis
of liquid and semi-liquid materials. Horizontal ATR
are used to analyze films, pastes, pliable solids and
fine powders. Thanks to the reproducible effective
pathlength, ATR is well suited for both qualitative
and quantitative applications. Several heating
options are available
GladiATR™ VisionDiamond ATR with sample view –monolithic diamond for easy positioning and analysis ofintractable samples
Page 14
HATR Multi-Reflection ATR – highest sensitivity for minor components
Page 17
ATRMax™ Variable Angle, Multi-ReflectionATR – research grade HATR
Page 21
VeeMAX™ ATRVariable Angle, Single-ReflectionATR – for depth profiling studies
Page 24
VATR™Classic Variable Angle ATR
Page 28
ATR Theory and ApplicationsPage 29
GladiATR™ Single Reflection ATR – monolithic diamond for intractablesamples and temperature studies
Page 12
MIRacle™ Single Reflection ATR – ideal for sample identification
Page 8
02_ATR 12-13-12_02_ATR 12/13/12 1:14 PM Page 7
PIK
ET
EC
HN
OL
OG
IES
WW
W.
PIK
ET
EC
H.
CO
M6
08
-27
4-2
72
1
8
MIRacle ATR – Fast and Easy IR Sampling
The PIKE MIRacle™ is a universal ATR sampling accessory foranalysis of solids, liquids, pastes, gels, and intractable materials.In its most popular configuration it is a single reflection ATRaccessory with high IR throughput which makes it ideal for sample identification and QA/QC applications. Advanced optionsinclude three reflection ATR crystal plates to optimize for lowerconcentration components. Easily changeable crystal plate designprovides analysis of a broad spectrum of sample types whileensuring constant sampling pathlength.
Single and three reflection ATR crystals are available to optimize general qualitative or quantitative analysis of minorcomponents.
MIRacle Optical DesignIn the patented MIRacle optical design the ATR crystal focuses the IRbeam and also provides the ATR sampling interface. This technologydelivers much higher throughput than competitive products,saves considerable time and produces higher quality spectra.
F E ATUR E S O F THE M IRAC L E
• Highest IR throughput – saving you time and improving youranalysis quality
• Complete flexibility – add options to your MIRacle as yoursampling needs change
• Highest value – for today’s competitive analytical andresearch needs
• Fully configurable – ZnSe, diamond, Ge and Si MIRacle crystal plates
• Pinned-in-place, changeable crystal plates – for fast andeasy sampling optimization
• Highest purity, type IIa diamond crystal – will not scratchand is chemically inert to acidic or caustic materials
• Optional specular reflectance plate – for measurement ofcoatings on reflective surfaces
• Choice of pressure clamps – high-pressure, digital high-pressure and micrometric sample clamps
• Sampling options – heating, temperature control, and flowthrough plate
MIRacle – Highest IR Throughput ATR
Thick Polymer Sample, using MIRacle with ZnSe Crystal and High-Pressure Clamp – No Sample Preparation.
MIRacle – High Throughput and Efficient Optical Design
02_ATR 12-13-12_02_ATR 12/13/12 1:14 PM Page 8
9
ATTENUATED
TOTAL
REFLECTANCE
– L
IQ
UI
DS
, SO
LI
DS
AN
DI
N-B
ET
WE
EN
MIRacle Crystal OptionsThe MIRacle ATR accessory is available with 4 different crystaltypes (ZnSe, diamond, Ge, and Si) and with unique versions ofthese crystal materials.
Crystal plates are pinned in place and easily changeable within seconds with no alignment required. With this flexibility,you can change the crystal type to exactly match your samplingrequirements. For example, diamond is ideal for brittle samplesbecause it will not scratch, whereas, Ge is ideal for carbon-filledsamples because of its high refractive index and lower depth of penetration. Three reflection crystal plates provide increasedsensitivity for minor components in liquid or non-rigid materials.
An optional liquids retainer andvolatiles cover set is compatible with allcrystal plates, eliminating the need topurchase flat and trough crystal plates.A high-pressure clamp is required foruse with the liquids retainer and thevolatiles cover.
Table 1 shows MIRacle ATR crystal characteristics includingrefractive index, spectral range cutoff, pH range and hardness forsingle reflection ATR crystal plates. Still have questions? Please callas we are pleased to discuss your sampling requirements.
MIRacle ATR Crystal Plates
“Faux” Black Pearl with MIRacle using Diamond ATR Crystal
Black Rubber Samples are best run using Ge ATR Crystal
Table 1: MIRacle Crystal Plate Specifications
Refractive Depth ofMIRacle Hardness Cutoff cm-1, Index @ Penetration pH RangeCrystal Plate Application kg/mm2 Spectral Range 1000 cm-1 @ 45°, µ of Sample
Diamond/ZnSe Ideal for hard samples, acids or alkaline 5700 525 2.4 2.00 1–14
Ge General purpose and carbon filled or rubber 550 575 4.0 0.66 1–14
Si Excellent for far-IR spectral measurement 1150 8900–1500, 475–40 3.4 0.85 1–12
ZnSe General purpose ATR crystal 120 520 2.4 2.00 5–9
MIRacle Crystal plates are covered by PIKE Technologies patent numbers 5,965,889 and 6,128,075 or are manufactured under license of 5,200,609,5,552,604 and 5,703,366.
Liquids Retainer andVolatiles Cover set
02_ATR 12-13-12_02_ATR 12/13/12 1:14 PM Page 9
PIK
ET
EC
HN
OL
OG
IES
WW
W.
PIK
ET
EC
H.
CO
M6
08
-27
4-2
72
1
10
MIRacle Pressure Clamp OptionsMIRacle pressure clamps are pinned in place and easily changeablewithin seconds. A high-pressure clamp is recommended for mostapplications and is available in basic and digital configurations.The digital version includes a high-pressure clamp and the DigitalForce Adapter (DFA) that attaches directly to the clamping assembly.The DFA’s embedded load cell exhibits high linearity, reproducibility,and exceptional accuracy. The magnitude of applied force is dis-played on an external easy-to-read LCD readout. The digital clampis ideal for applications that require controlled and reproduciblepressure. All clamps include tips for hard, soft and pellet-shapedsamples. High-pressure clamps are calibrated to deliver over10,000 psi of pressure when used with the single reflection crystal plates.
Ability to deliver high pressure is very important for achievingspectral quality. In the example below, we demonstrate spectraldifferences for a porous polymer sample measured with themicrometer clamp and the high-pressure clamp. Clearly the spectrum obtained using the high-pressure clamp is required for a high quality result.
MIRacle high-pressure clamps utilize a slip-clutch mechanismto prevent excessive pressure from being applied to the crystal.
MIRacle Sampling OptionsThe MIRacle can be configured with optional resistively heatedcrystal plates using a PIKE temperature control module. Digitaland digital with PC control versions are available. The PC controlmodule includes TempPRO software which provides a graphicaluser interface for temperature control and kinetic measurements.
MIRacle ATR SummaryThe MIRacle ATR accessory is a high performance FTIR samplingtool for solid, liquid, or polymer samples. Easily changeable crystalplates provide optimized spectral data for unique sample types.With options for single or three reflection crystal plates, severalpressure clamp styles and heating or cooling, the MIRacle is ableto address a wide range of FTIR sampling applications.
Porous Polymer Sample Measured Using High and Low-Pressure Clamp
Max lbs Crystal MIRacle Clamp Pressures Pressure Diameter, mm PSI
High-Pressure Clamps 401.8 10,141
6.0 913
Micrometer Pressure Clamp 81.8 2,028
6.0 183
Note: All clamps except Micrometer are high-pressure
TempPRO software for graphical setup and control ofkinetic measurements
MIRacle with Optional HeatedCrystal Plate and PIKETemperature Control Module
MIRacle Digital ClampIdeal for controlled pressure
MIRacle Pressure Clamps are Pinned in Place and Easily Upgraded
MIRacle ConfinedSpace Clamp – For instruments with limited sampling area
MIRacle High-PressureClamp – Ideal for routine sampling
MIRacle MicrometerClamp – For low pressure applications
02_ATR 12-13-12_02_ATR 12/13/12 1:14 PM Page 10
11
ATTENUATED
TOTAL
REFLECTANCE
– L
IQ
UI
DS
, SO
LI
DS
AN
DI
N-B
ET
WE
EN
MIRacle Base Optics (must select, insert spectrometer model for XX)PA R T NUMB E R D E S C R I P T I O N
025-18XX MIRacle ATR Base Optics/Platform Assembly
Notes: MIRacle Base Optics includes purge tubes, purge kit and spectrometer basemount. Please see the FTIR instrument code sheet.
MIRacle Crystal Plates (must select 1 or more)PA R T NUMB E R D E S C R I P T I O N
025-2108 Diamond/ZnSe Performance Crystal Plate
025-2107 Diamond/ZnSe HS Performance Crystal Plate
025-2118 3 Reflection Diamond/ZnSe Performance Crystal Plate
025-2018 ZnSe Performance Crystal Plate
025-2038 3 Reflection ZnSe Performance Crystal Plate
025-2058 Ge Performance Crystal Plate
025-2098 Si Performance Crystal Plate
025-2208 Specular Reflection Performance Plate
Notes: MIRacle Crystal Plates are pre-aligned and pinned-in-place. Changing crystalplates is easy and fast to optimize sampling results. Crystal plates are manufacturedusing polished stainless steel for chemical resistance. The diamond/ZnSe crystalplate is available with optional Hastelloy (HS) metal for exceptionally caustic oracidic samples.
MIRacle Sampling OptionsPA R T NUMB E R D E S C R I P T I O N
025-4018 Heated ZnSe Performance Crystal Plate
025-4058 Heated Ge Performance Crystal Plate
025-4108 Heated Diamond/ZnSe Performance Crystal Plate (60 °C Max)
026-5012 Flow-Through Attachment, sample volume 100 µL
026-5013 Liquids Retainer and Volatiles Cover Set
026-3051 Volatiles Cover for Performance Plates
026-5010 Liquids Retainer for Performance Plates
076-1220 Digital Temperature Control Module
076-1420 Digital Temperature Control Module, PC Control
Notes: Flow through attachment, liquids retainer and volatiles cover are compatiblewith all crystal plate offerings but require High-Pressure Clamp, PN 025-3020 or PN 025-3035, sold separately. Temperature controller selection is required for heated crystal plates. Digital temperature controller with PC control includesTempPRO software.
MIRacle Pressure Clamps (must select 1 or more for solids or polymer analysis)PA R T NUMB E R D E S C R I P T I O N
025-3020 High-Pressure Clamp
076-6025 Digital Force Adapter for High-Pressure Clamp
025-3050 Micrometric, Low-Pressure Clamp
025-3035 Confined Space Clamp
Notes: The High-Pressure Clamp is recommended for general applications. Pressure clamps include a flat tip, a swivel tip and a concave tip. The Digital ForceAdapter requires High-Pressure Clamp, PN 025-3020, sold separately.
MIRacle Replacement PartsPA R T NUMB E R D E S C R I P T I O N
025-3095 Flat Tip for High-Pressure Clamps
025-3093 Swivel Tip for High-Pressure Clamps
025-3092 Concave Tip for High-Pressure Clamps
025-3096 Sealed Pressure Tip for High-Pressure Clamp
025-3052 Flat Tip for Micrometric Clamp
025-3061 Swivel Tip for Micrometric Clamp
025-3054 Concave Tip for Micrometric Clamp
025-3053 MIRacle Micrometer Clamp Tip Assortment
025-3094 7.8 mm ATR Pressure Tip
025-3099 High-Pressure Tip Assortment
Notes: Please contact PIKE Technologies for items not described in this list.Reconditioning service for used MIRacle crystal plates is available.
ORDER I NG IN FORMAT I ON
MIRACLE ACCESSORY SPEC IF ICAT IONS
ATR Crystal Choices Diamond/ZnSe, Ge, ZnSe, Si
Crystal Plate Mounting User changeable plates
Crystal Plate Mount Stainless steel
Angle of Incidence 45 degrees, nominal
Crystal Dimensions, Surface 1.8 mm
Pressure Device Rotating, continuously variable pressure;click stop at maximum
Digital Force Adapter (option) Load cell sensor for precise and reproducible pressure control. Attachesdirectly to MIRacle clamp. Digital readout.
Maximum Pressure 10,000 psi
Sample Access 55 mm, ATR crystal to pressure mount
Heating Options Ambient to 60 or 130 ºC maximum
Accuracy +/- 0.5%
Sensor Type 3 wire Pt RTD (low drift, high stability)
Temperature Control Digital or digital with PC control (up to 10 ramps, automated data collection, USB interface)
Input Voltage 90–264 VAC, auto setting, external power supply
Operating Voltage 2.5 A/24 VDC/50 W
Specular Reflection Option Optional, 45 degree nominal angle ofincidence
Purge Sealing Purge tubes and purge line connectorincluded
Accessory Dimensions 104 x 103 x 210 mm(W x D x H) (excludes FTIR baseplate and mount)
FTIR Compatibility Most, specify model and type
02_ATR 12-13-12_02_ATR 12/13/12 1:14 PM Page 11
PIK
ET
EC
HN
OL
OG
IES
WW
W.
PIK
ET
EC
H.
CO
M6
08
-27
4-2
72
1
12
The GladiATR™ is an all new optical design from PIKE Technologiesproviding the highest energy throughput, highest available pres-sure, widest spectral range and offering optional heated or cooledcrystal plates. The GladiATR is a highly durable and rugged designto be used in environments where large numbers of samples aremeasured, where samples may be intractable solids, where youwant the best quality spectrum every time and where you needflexibility for new sample types in the future.
The GladiATR diamond crystal is a monolithic design whichwill not scratch or fracture even at extreme pressures. This designpermits analysis of hard, intractable objects such as coated metalwires, polymer pellets and geological samples without damage tothe ATR crystal. The diamond crystal is brazed into the stainlesssteel plate, which enables this ATR to be compatible with pressureup to 30,000 psi.
The energy throughput of the GladiATR is exceptional; twicethat of other monolithic diamond ATR accessories – significantlyimproving spectral quality and reducing sampling time.
The GladiATR is designed and manufactured using all reflectingoptics providing full spectral range in the mid-IR and far-IR spectralregions. An optional Ge crystal plate is available for analysis of highrefractive index samples. Crystal plates are easily changeable.
GladiATR – Highest Performance Diamond ATR
F E ATUR E S O F THE G L AD IATR
• Diamond crystal design – cannot scratch or fracture• Extreme pressure application – for hard and demandingsolid samples
• Highest energy throughput design – for excellent quality FTIRspectra and minimum scan time
• All reflective optics – full spectral range for mid-IR and far-IRanalysis
• Optional Ge crystal plate – for high refractive index samples• Heated crystal plate options – taking ATR temperature studies up to 300 °C
• 300 °C Diamond Version – for high temperature/high pressure materials studies
• Compatible with most FTIR spectrometers
ATR/FTIR spectrum of polymer pellet run on GladiATR with diamondcrystal. Spectral range in the mid-IR is 4000–400 cm-1.
Spectrum of sulfathiazole using GladiATR with diamond crystal plateand far-IR optics in FTIR
GladiATR with heated diamond crystal plate and temperature controller
02_ATR 12-13-12_02_ATR 12/13/12 1:14 PM Page 12
13
ATTENUATED
TOTAL
REFLECTANCE
– L
IQ
UI
DS
, SO
LI
DS
AN
DI
N-B
ET
WE
EN
Temperature controlled crystal plates are available for thermalstudy of materials. PIKE Technologies offers temperature controllerswith digital and PC programmable set points.
The GladiATR high performance diamond ATR is available inconfigurations to fit most FTIR spectrometers.
Selection of the digital control module, PC control includes PIKETempPRO™ software for graphical setup and automated data collectionfor thermal experiments
ATR/FTIR spectra from cure of thermoset epoxy using the heated diamondcrystal plate on the GladiATR
GLADIATR ACCESSORY SPEC I F I CAT IONS
ATR Crystal Choices Diamond, germaniumCrystal Plate Mounting User changeable platesCrystal Type MonolithicDiamond Mounting BrazedCrystal Plate Mounts Stainless steelAngle of Incidence 45 degrees, nominalCrystal Dimensions, Surface 3.0 mm diameterOptics All reflectivePressure Device Rotating, continuously variable pressure;
click stop at maximumDigital Force Adapter Load cell sensor for precise and reproducible(option) pressure control. Attaches directly to
GladiATR clamp. Digital readout.Maximum Pressure 30,000 psiSample Access 80 mm, ATR crystal to pressure mountSpectral Range, Diamond 4000 to 30 cm-1 (IR optics dependent)Heating Options Diamond, 210 or 300 ºC maximum
Accuracy +/- 0.5%Sensor Type 3 wire Pt RTD (low drift, high stability)Temperature Control Digital or digital with PC control (up to
10 ramps, automated data collection, USB interface)
Input Voltage 100–240 VAC, auto setting, external powersupply; 110/220 VAC switchable (300 °C version)
Operating Voltage 4A/24 VDC, 100 W6A/24 VAC, 150 W (300 °C version)
Cooling Options Liquid jacketed crystal plates availableSpecular Reflection Option Optional, 45 degree nominal angle of incidencePurge Sealing Purge tubes and purge line connector includedAccessory Dimensions 140 x 205 x 340 mm (W x D x H) (excludes FTIR baseplate and mount)FTIR Compatibility Most, specify model and type
GladiATR Base Optics (must select, insert spectrometer model for XX)PA R T NUMB E R D E S C R I P T I O N
026-18XX GladiATR Single Reflection ATR Base Optics, with heating capability up to 210 °C
026-17XX GladiATR 300 Single Reflection ATR Base Optics, 300 °C
Notes: All GladiATRs include purge tubes, purge kit, and selected spectrometer basemount. GladiATR 300 is configured and available only with the Diamond plate.Crystal plates for the basic model (026-18XX) must be selected from the table below.High-Pressure Clamp, Digital Force Adapter and Liquids Retainer/Volatiles Cover areoptional and need to be ordered separate, if required.
GladiATR Stainless Top (must select one or more)PA R T NUMB E R D E S C R I P T I O N
026-2001 GladiATR Standard Stainless Top
026-2002 GladiATR Heated Stainless Top
026-2003 GladiATR Liquid Jacketed Stainless Top
Notes: Stainless top is not required for 300 °C version.
GladiATR Crystal Plates for GladiATR (must select one or more)PA R T NUMB E R D E S C R I P T I O N
026-2100 Diamond Crystal Plate
026-2050 Ge Crystal Plate
026-2200 Specular Reflection Plate
Notes: GladiATR Crystal Plates are pre-aligned and pinned-in-place. Changing crystalplates is easy and fast to optimize sampling results.
GladiATR Pressure Clamp, all models (must select for solid or powdered samples)PA R T NUMB E R D E S C R I P T I O N
026-3020 High-Pressure Clamp
076-6026 Digital Force Adapter for High-Pressure Clamp
Notes: The High-Pressure Clamp is required for analysis of solids, powders and useof liquids retainer and/or Digital Force Adapter (Digital Force Adapter cannot beused with heated crystal plates). Pressure clamp includes a flat tip, a swivel tip anda concave tip.
GladiATR Temperature Controlled Crystal PlatesPA R T NUMB E R D E S C R I P T I O N
026-4102 Heated Diamond Crystal Plate, 300 °C (GladiATR 300 only)
026-4100 Heated Diamond Crystal Plate, 210 °C
026-4050 Heated Ge Crystal Plate, 130 °C
026-4110 Liquid Jacketed Diamond Crystal Plate
026-4150 Liquid Jacketed Ge Crystal Plate, 130 °C
076-1220 Digital Temperature Control Module, 210 °C
076-1420 Digital Temperature Control Module, PC Control, 210 °C
076-1210 Digital Temperature Control Module, 300 °C
076-1410 Digital Temperature Control Module, PC Control, 300 °C
Notes: For heated diamond crystal plates, maximum crystal temperature is 300 or210 °C, depending on the GladiATR model selected. Ge becomes optically opaque at190 °C. Max recommended temperature for this crystal is 130 °C. Temperature controller is required for heated crystal plates. Digital temperature controller, PC control includes PIKE TempPRO software. Liquid jacketed crystal plates require customer provided circulator.
GladiATR Sampling Options PA R T NUMB E R D E S C R I P T I O N
026-5012 Flow-Through Attachment, 210 °C, sample volume 100 µL
026-5014 Flow-Through Attachment, 300 °C, sample volume 100 µL
026-5013 Liquids Retainer and Volatiles Cover Set
026-5015 Liquids Retainer and Volatiles Cover Set, 300 °C
026-5010 Liquids Retainer for Performance Plates, 260 °C
026-3051 Volatiles Cover for Performance Plates
Notes: Flow-Through Attachment, Liquids Retainer and Volatiles Cover are compatiblewith all crystal offerings (require High-Pressure Clamp).
ORDER I NG IN FORMAT I ON
02_ATR 12-13-12_02_ATR 12/13/12 1:14 PM Page 13
PIK
ET
EC
HN
OL
OG
IES
WW
W.
PIK
ET
EC
H.
CO
M6
08
-27
4-2
72
1
14
GladiATR Vision – Diamond ATR with Sample View
F E ATUR E S O F THE G L AD IATR V I S I ON
• View through diamond crystal – easily find sample point• 110X magnification – find and position small sample areas• Optional USB image capture – document sample image• Diamond crystal design – cannot scratch or fracture• Highest energy throughput design – for excellent quality FTIRspectra and minimum scan time
• All reflective optics – full spectral range for mid-IR and far-IR analysis
• Optional heated, viewing crystal plate• Compatible with most FTIR spectrometers
Diamond crystal plate of the GladiATR Vision accessory. IR beam and visible illumination meet at the sample position.
ATR/FTIR spectrum of print area on paper run on GladiATR Vision withdiamond crystal. Image of the analysis area is shown in the inset.Spectral range is 4000–400 cm-1 with standard FTIR optics.
The GladiATR Vision™ is a novel sampling tool which couplessmall area infrared analysis with simultaneous viewing. Samplesare placed face down and positioned on the diamond crystalwhile its image is projected in real-time on the LCD screen. Findingand optimizing the sample placement for specific analysis areas iseasy and fast! Analysis of thick or non-transparent samples is noproblem because viewing is through the diamond crystal.
The GladiATR Vision accessory utilizes an innovative opticaldesign with IR beam and visible optical image converging at thesample position – ensuring that “What you see is what you sample!”The 110X magnification of the sample image enables the positioningof even relatively small samples into the center of the diamondcrystal for optimized analysis. Analysis of samples as small as 50 microns in size is doable with the GladiATR Vision accessory.Visible images from the GladiATR Vision are of highest qualitycolor rendition because its refractive optics are fully transparent.
The GladiATR Vision optical design is all reflective, preservingthe full spectral range inherent to diamond. For standard mid-IRFTIR spectrometers, the spectral range available with the GladiATRVision will be 4000–400 cm-1. For FTIR spectrometers equipped withfar-IR optics, the spectral range is extended to less than 50 cm-1.
The GladiATR Vision diamond ATR is available in configurationsto fit most FTIR spectrometers.
ATR / FTIR spectrum of 200 micron fiber run on GladiATR Vision with diamond crystal. Compressed fiber image is shown with the spectrum.
02_ATR 12-13-12_02_ATR 12/13/12 1:14 PM Page 14
15
ATTENUATED
TOTAL
REFLECTANCE
– L
IQ
UI
DS
, SO
LI
DS
AN
DI
N-B
ET
WE
EN
GladiATR Vision Base Optics (must select one, insert spectrometer model for XX)PA R T NUMB E R D E S C R I P T I O N
026-19XX GladiATR Vision Base Optics
Notes: GladiATR Vision Base Optics versions include purge tubes, illumination powersupply, purge kit and spectrometer base mount. Please see the FTIR instrumentcode sheet. USB interface software enables image capture on your PC.
GladiATR Stainless Top (must select one or more)PA R T NUMB E R D E S C R I P T I O N
026-2004 GladiATR Vision Stainless Top
026-2005 GladiATR Vision Heated Stainless Top
026-2006 GladiATR Vision Liquid Jacketed Stainless Top
GladiATR Vision Crystal Plates (must select one or more)PA R T NUMB E R D E S C R I P T I O N
026-2102 GladiATR Vision Diamond Crystal Plate
026-2050 Ge Crystal Plate (non-viewing)
026-2200 Specular Reflection Plate (non-viewing)
026-2202 Specular Reflection Plate (viewing)
Notes: GladiATR Crystal Plates are pre-aligned and pinned-in-place. Changing crystal plates is easy and fast to optimize sampling results. Only the GladiATR VisionDiamond Crystal Plate is compatible with sample viewing.
GladiATR Vision High-Pressure Clamp (must select for solid or powdered samples)PA R T NUMB E R D E S C R I P T I O N
026-3020 High-Pressure Clamp
076-6026 Digital Force Adapter for High-Pressure Clamp
Notes: The High-Pressure Clamp is required for analysis of solids, powders and useof liquids retainer and/or Digital Force Adapter (Digital Force Adapter cannot beused heated crystal plates). Pressure clamp includes a flat tip, a swivel tip and aconcave tip.
GladiATR Vision Temperature Controlled Crystal PlatePA R T NUMB E R D E S C R I P T I O N
026-4101 Heated Diamond Crystal Plate, 210 °C, Vision
026-4050 Heated Ge Crystal Plate, 130 °C (non-viewing)
026-4112 Liquid Jacketed Diamond Crystal Plate
076-1220 Digital Temperature Control Module
076-1420 Digital Temperature Control Module, PC Control
Notes: Digital temperature controller, PC control includes PIKE TempPRO software.
GladiATR Vision Sampling OptionsPA R T NUMB E R D E S C R I P T I O N
026-5012 Flow-Through Attachment, sample volume 100 µL
026-5013 Liquids Retainer and Volatiles Cover Set
026-5010 Liquids Retainer for Performance Plates, 260 °C
026-3051 Volatiles Cover for Performance Plates
Notes: Flow-Through Attachment, Liquids Retainer and Volatiles Cover are compatiblewith all crystal offerings (require High-Pressure Clamp).
ORDER I NG IN FORMAT I ONGLADIATR VIS ION ACCESSORY SPEC I F I CAT IONS
ATR Crystal Choices Diamond, germanium (non-viewing)
Crystal Plate Mounting User changeable plates
Crystal Type Monolithic
Diamond Mounting Brazed
Crystal Plate Mounts Stainless steel
Angle of Incidence 45 degrees, nominal
Crystal Dimensions, Surface 3.0 mm diameter
Optics All reflective
Pressure Device Rotating, continuously variable pressure;click stop at maximum
Digital Force Adapter (option) Load cell sensor for precise and reproduciblepressure control. Attaches directly toGladiATR clamp. Digital readout.
Maximum Pressure 30,000 psi
Sample Access 80 mm, ATR crystal to pressure mount
Spectral Range, Diamond 4000 to 30 cm-1 (IR optics dependent)
Viewing Optics Integrated 4" LCD
Magnification 110X magnification
View Area 770 x 590 microns
Optional Image Save USB image capture
Viewing Mode Through diamond crystal
Input Voltage 100–240 V, auto setting, external power supply
Operating Voltage, Wattage 12 VDC, 18 W maximum
Heating Options Diamond, 210 ºC maximum
Accuracy +/- 0.5%
Sensor Type 3 wire Pt RTD (low drift, high stability)
Temperature Control Digital or digital with PC control (up to 10 ramps, automated data collection,USB interface)
Input Voltage 100–240 VAC, auto setting, externalpower supply
Operating Voltage 4A/24 VDC, 100 W
Specular Reflection Option Optional, 45 degree nominal angle of incidence
Purge Sealing Purge tubes and purge line connectorincluded
Accessory Dimensions 140 x 225 x 340 mm (W x D x H) (excludes FTIR baseplate and mount)
FTIR Compatibility Most, specify model and type
02_ATR 12-13-12_02_ATR 12/13/12 1:14 PM Page 15
PIK
ET
EC
HN
OL
OG
IES
WW
W.
PIK
ET
EC
H.
CO
M6
08
-27
4-2
72
1
16
Dedicated GladiATR and GladiATR Vision Sampling Tools – More Options to Address Your Specific Application RequirementsExpanded Range Ge Crystal PlateDue to the compact crystal size and the all-reflective optics of theGladiATR platform, the Ge Crystal Plate offers an expanded spectralrange from 4000–450 cm-1. A Ge ATR crystal is used to measuresamples with a high refractive index. Types of high refractivematerials that would benefit from sampling on the expandedrange Ge ATR crystal are carbon black filled samples and inorganicmaterials such as oxides, aluminas, titania, and minerals. The Ge crystal plate (non-viewing) may be fitted for the GladiATR orGladiATR Vision. Crystal plates are easily interchangeable. A heatedversion is available.
Specular Reflection PlateThe GladiATR may be converted from an ATR accessory to a specular reflection accessory by using the Specular ReflectionPlate. A viewing Specular Reflection Plate is available for theGladiATR Vision. The angle of incidence is 45 degrees, and plate is easily interchangeable with ATR plates.
Flow-Through AttachmentThe Flow-Through Attachment is used for continuous monitoringor handling samples that pose a hazard from ambient exposure.Samples are introduced using the Luer-Lok fitting by connecting asyringe or a flow line. The High-Pressure Clamp is required.
Liquids Retainer and Volatiles CoverThe Liquids Retainer offers a trough configuration for GladiATRand GladiATR Vision. The volatiles cover reduces the amount ofevaporation of a highly volatile liquid sample on the surface ofthe crystal. The High-Pressure Clamp is required.
Digital Force Adapter for High-Pressure ClampThe Digital Force Adapter attaches directly to the clampingassembly to precisely measure the applied force by using anembedded load cell that exhibits high linearity and exceptionalaccuracy. The magnitude of applied force is displayed on anexternal easy-to-read LCD readout. The digital clamp is ideal forapplications that require controlled and reproducible pressure.
ORDER I NG IN FORMAT I ON
GladiATR Options PA R T NUMB E R D E S C R I P T I O N
026-2050 Ge Crystal Plate (non-viewing)
026-4050 Ge Crystal Plate, 130 °C (non-viewing)
076-1220 Digital Temperature Control Module
076-1420 Digital Temperature Control Module, PC control
026-2200 Specular Reflection Plate (non-viewing)
026-2202 Specular Reflection Plate (viewing)
076-6026 Digital Force Adapter for High-Pressure Clamp
026-5012 Flow-Through Attachment, 210 °C, sample volume 100 µL
026-5014 Flow-Through Attachment, 300 °C, sample volume 100 µL
026-5013 Liquids Retainer and Volatiles Cover Set
026-5015 Liquids Retainer and Volatiles Cover Set, 300 °C
026-5010 Liquids Retainer for Performance Plates
026-3051 Volatiles Cover for Performance Plates
Note: The heated Ge crystal plate requires a temperature control module.
Spectrum of malachitegreen oxalate collectedusing the GladiATR withGe crystal plate
GladiATR SpecularReflection Plate
Flow-ThroughAttachment
Liquids Retainer and VolatilesCover Set
GladiATR with Digital Force Adapter
02_ATR 12-13-12_02_ATR 12/18/12 9:02 AM Page 16
17
ATTENUATED
TOTAL
REFLECTANCE
– L
IQ
UI
DS
, SO
LI
DS
AN
DI
N-B
ET
WE
EN
Horizontal Attenuated Total Reflectance (HATR) accessories successfully replace constant path transmission cells, salt platesand KBr pellets used in the analysis of liquid, semi-liquid materialsand a number of solids. HATRs feature a constant and reproducibleeffective pathlength and are well suited for both qualitative andquantitative applications. In general, sampling is achieved byplacing the sample onto the HATR crystal – generally eliminatingsample preparation.
PIKE Technologies HATR products are available in 2 baseoptic configurations. The HATR is an in-compartment design forsamples which fit into the FTIR sample compartment.
The PIKE Technologies HATRPlus is an out-of-compartmentdesign for samples which are larger and do not fit into the FTIRsample compartment. The sampling surface of the HATRPlusextends above the FTIR cover, thereby permitting analysis of verylarge samples. Applications examples include coatings on largemanufactured components, layered composition analysis on largeobjects, and skin analysis in the health care industry.
The PIKE Technologies HATRs are high performance accessories,carefully designed to provide excellent results with minimum effort.The accessories are easily installed in the sample compartment,locking into position on the sample compartment baseplate.
Stable alignment provides excellent analytical precision.Crystal plate changeover is rapid, allowing a wide range of samplesto be analyzed with maximum convenience. PIKE TechnologiesHATRs have been optimized for maximum optical throughput andexcellent quality spectra can be obtained from demanding samples.Several high quality crystal materials covering a full spectrum ofapplications are available. Trough crystal plates are sealed usingmetallic gaskets, eliminating premature failure and the risk ofcross-contamination associated with inferior, epoxy-bonded systems. Flat crystal plates are designed with positive surfacerelief to aid in improved sample contact.
All PIKE HATRs include a purge tube interface for the FTIRspectrometer. This provides full integration of the accessory withthe FTIR spectrometer’s purging system (sealed and desiccated orpurged) and removal of water and carbon dioxide artifacts fromthe FTIR spectra. Thanks to this, purging is very efficient and thespectrometer can be operated with the sample compartmentdoor open.
F E ATUR E S O F THE HATR
• Excellent energy throughput offering high signal-to-noiseratio and spectral quality
• Up to 20 internal reflections for maximum sensitivity for low concentration components
• Removable crystal plates with pinned positioning for highprecision and quick cleanup
• HATR plates with ZnSe, KRS-5, Ge, AMTIR or Si crystals with selectable face angles to optimize sampling depth
• In-compartment (HATR) and out-of-compartment (HATRPlus)versions for small and extra large sample sizes
• Several temperature controlled and flow-through crystalplate options
HATR Accessory – in-compartment HATR for liquid and solid samples
HATRPlus™ Accessory –out-of-compartment
HATR for liquid and extra large solid samples
FTIR spectrum of fuel additive using HATR trough plate with ZnSe crystal
Multiple Reflection HATR – Maximum Sensitivity and Highly Versatile FTIR Sampling
02_ATR 12-13-12_02_ATR 12/13/12 1:14 PM Page 17
PIK
ET
EC
HN
OL
OG
IES
WW
W.
PIK
ET
EC
H.
CO
M6
08
-27
4-2
72
1
18
HATR Crystal Plate ChoicesPIKE Technologies HATR crystal plates are available in trough andflat plate configurations.
The trough plate is designed for easy sampling, with a large,recessed crystal to accommodate the sample – generally a liquid,powder, or paste. The trough plate is ideal when samples must be cleaned from the crystal with some type of aqueous or organic solvent.
Typically, only a thin layer of the sample needs to be appliedonto the crystal surface. For fast evaporating samples, a volatilescover should be used to cover the sampling area.
Soft powders will often produce good spectra when analyzedby HATR, assuming that they can be put in intimate contact withthe crystal. A powder press option is used to achieve this. Thisdevice is placed directly on top of the sample filled trough andpressed by hand until the desired result is obtained.
The flat plate is used for the analysis of solid materials –including polymer and film samples. It is ideal for solid sampleswhich are too large to fit within the trough plate configuration.
The crystal is mounted slightly above the surface of the metalplate, which helps to achieve good crystal/sample contact whenthe flat plate press is used (the press attaches easily to the back ofthe HATR with two thumb screws).
The ZnSe and Ge 45° flat plates are available in a sealed version, which is ideal for sampling of oils and other types of low surface tension liquids.
FTIR spectrum of coating on inner wall of food container by HATR withZnSe flat plate and pressure clamp
PIKE Technologies Crystal Plate Choices – for the HATR and HATRPlus
Flat plate HATR crystal plate – ideal for solids, polymer films and coatings
Trough plate HATR crystal plate – ideal for liquids, powders, pastes and gels HATR with Heated Trough Plate – foreground shows Heated Flow-Through Cell
PIKE TempPRO Software for kinetic experiments with our ResistivelyHeated Crystal Plates
All resistively heated HATR plates are controlled by PIKE temperature controllers in digital or digital PC versions. The selection of the digital PC version includes PIKE TempPRO software,which provides a graphical user interface for temperature controland kinetic measurements.
02_ATR 12-13-12_02_ATR 12/13/12 1:14 PM Page 18
19
ATTENUATED
TOTAL
REFLECTANCE
– L
IQ
UI
DS
, SO
LI
DS
AN
DI
N-B
ET
WE
EN
A large number of temperature-controlled and flow-throughsampling plates are available for PIKE Technologies HATRs – all are pin-mounted to the HATR with no alignment required.
All temperature controlled and flow-through crystal plateoptions are compatible and interchangeable with HATR andHATRPlus products. PIKE Technologies temperature controllersprovide static or ramped temperature control.
All PIKE HATR flow cells have removable HATR crystals. Theupper and lower part of the crystal plate is removed, and thecrystal can be easily taken out of the plate. This feature enablesreplacement of the crystals and facilitates special cleaning forproteins and other “sticky” samples.
For special applications where you need to look at coatings onan HATR crystal, PIKE Technologies offers the RCPlate™ option. Thenew RCPlate is designed to enable easy removal and reinsertionof the HATR crystal. Applications include analysis of coatings,mono-molecular layers, or bio-films deposited directly upon theHATR crystal. With these new RCPlates, it is easy to collect thebackground spectrum on the clean crystal, remove the HATR crystal from the RCPlate, coat the crystal and then reposition itinto the RCPlate to collect the sample spectrum.
SummaryThe PIKE Technologies HATR accessory provides high sensitivityfor analysis of low concentration components in liquid, solid, andpolymer samples. The highly flexible accessory is available for in-compartment and out-of-compartment configurations with complete selection of crystal material, sample format, and temperature and flow-through configurations.
Do you need an HATR product or feature not shown here inour catalog? Please contact us to discuss your application.
HATR with Flow Cell (background). Liquid Jacketed trough plate is shownin foreground.
RCPlate for HATR
Complete HATR SystemsBundled HATR Systems (must select, insert spectrometer model for XX)PA R T NUMB E R D E S C R I P T I O N
022-10XX HATR Trough Plate System with 45º ZnSe CrystalIncludes: Trough Plate, Volatiles Cover and Powder Press
022-11XX HATR Flat Plate System with 45º ZnSe CrystalIncludes: Flat Plate and HATR Pressure Clamp
022-12XX HATR Combined Trough and Flat Plate System with 45º ZnSe CrystalsIncludes: Trough Plate, Flat Plate, Volatiles Cover, Powder Press and Sample Clamp
024-11XX HATRPlus Flat Plate System with 45º ZnSe CrystalIncludes: Flat Plate and HATR Pressure Clamp
Notes: HATR and HATRPlus Systems may be purchased with crystal plates otherthan ZnSe. Just add – Ge for germanium, – KR for KRS-5, -AM for AMTIR, or –Si forSilicon. Additional plates can be added to an order for any system above. Otherconfigurations may be selected from the options below. Please see the FTIR instrument code sheet.
Configurable HATR SystemsHATR Base Optics (insert spectrometer model for XX)PA R T NUMB E R D E S C R I P T I O N
022-19XX HATR Platform Optics Assembly
024-19XX HATRPlus Platform Optics Assembly
Notes: HATR and HATRPlus Platform Optics Assemblies include volatiles cover, powder press, purge tubes, purge kit and spectrometer base mount. Please see theFTIR instrument code sheet.
HATR and HATRPlus Crystal Plates (must select 1 or more)PA R T NUMB E R D E S C R I P T I O N
022-2010-45 Trough Plate, ZnSe, 45°
022-2020-45 Flat Plate, ZnSe, 45°
022-2024-45 Sealed Flat Plate, ZnSe, 45°
022-2012-45 Trough Plate, ZnSe, 45°, 2 mm
022-2022-45 Flat Plate, ZnSe, 45°, 2 mm
022-2030-45 Trough Plate, KRS-5, 45°
022-2040-45 Flat Plate, KRS-5, 45°
022-2050-45 Trough Plate, Ge, 45°
022-2060-45 Flat Plate, Ge, 45°
022-2064-45 Sealed Flat Plate, Ge, 45°
022-2052-45 Trough Plate, Ge, 45°, 2 mm
022-2062-45 Flat Plate, Ge, 45°, 2 mm
022-2070-45 Trough Plate, AMTIR, 45°
022-2080-45 Flat Plate, AMTIR, 45°
022-2090-45 Trough Plate, Si, 45°
022-2100-45 Flat Plate, Si, 45°
Notes: HATR Crystal Plates are pre-aligned and pinned-in-place. Changing crystalplates is easy and fast to optimize sampling results. For most HATR crystal plates, 30 and 60 degree face angles are also available. Due to critical angle ZnSe, KRS-5 and AMTIR are not available in 30 degree face angle. Where not noted, crystals are 4 mm thick and generate 10 internal reflections. 2 mm crystals generate20 reflections (45° cut). If you need a crystal not listed here, please contact us.
ORDER I NG IN FORMAT I ON
02_ATR 12-13-12_02_ATR 12/13/12 1:14 PM Page 19
PIK
ET
EC
HN
OL
OG
IES
WW
W.
PIK
ET
EC
H.
CO
M6
08
-27
4-2
72
1
20
ORDER I NG IN FORMAT I ON
HATR and HATRPlus Pressure Clamp (must select for solids, films or powder analysis)PA R T NUMB E R D E S C R I P T I O N
022-3050 HATR (pivoting) Pressure Clamp
022-3054 HATR High-Pressure Clamp
024-3050 HATRPlus (pivoting) Pressure Clamp
024-3053 HATRPlus High-Pressure Clamp
Notes: The pressure clamp is required for solids, films, coatings and powdered samples. Maximum force for (pivoting) Pressure Clamp and High-Pressure Clamp is13 lbs and 30 lbs respectively.
HATR and HATRPlus Flow CellsPA R T NUMB E R D E S C R I P T I O N
022-4010 HATR Flow Cell, ZnSe, 45°
022-4020 HATR Flow Cell, AMTIR, 45°
022-4030 HATR Flow Cell, KRS-5, 45°
022-4040 HATR Flow Cell, Si, 45°
022-4050 HATR Flow Cell, Ge, 45°
Notes: HATR flow cells include Luer-Lok fittings for easy connection with a syringe. A set of 1/16" Swagelok fittings are included with each flow cell for connection with1/16" tubing. Flow cell volume is 500 µL.
HATR and HATRPlus Liquid Jacketed Crystal PlatesPA R T NUMB E R D E S C R I P T I O N
022-5310 HATR Liquid Jacketed Trough Plate, ZnSe, 45°
022-5320 HATR Liquid Jacketed Trough Plate, AMTIR, 45°
022-5330 HATR Liquid Jacketed Trough Plate, KRS-5, 45°
022-5340 HATR Liquid Jacketed Trough Plate, Si, 45°
022-5350 HATR Liquid Jacketed Trough Plate, Ge, 45°
Notes: Liquid jacketed crystal plates require customer provided circulating waterbath. Liquid jacketed crystal plates enable heating to 130 °C and cooling.
HATR and HATRPlus Heated Crystal PlatesP/N FORSINGLE RTD D E S C R I P T I O N
022-5110 HATR Heated Trough Plate, ZnSe, 45°
022-5120 HATR Heated Trough Plate, AMTIR, 45°
022-5130 HATR Heated Trough Plate, KRS-5, 45°
022-5140 HATR Heated Trough Plate, Si, 45°
022-5150 HATR Heated Trough Plate, Ge, 45°
PA R T NUMB E R D E S C R I P T I O N
022-5210 HATR Heated Flow-Through Cell, ZnSe, 45°
022-5220 HATR Heated Flow-Through Cell, AMTIR, 45°
022-5230 HATR Heated Flow-Through Cell, KRS-5, 45°
022-5240 HATR Heated Flow-Through Cell, Si, 45°
022-5250 HATR Heated Flow-Through Cell, Ge, 45°
PA R T NUMB E R D E S C R I P T I O N
076-1420 Digital Temperature Control Module, PC Control
076-1220 Digital Temperature Control Module
Notes: Temperature is adjustable to 130 °C for heated trough and flow-thru plates.Resistance heated plates require selection of a PIKE Technologies TemperatureController. PC Control Module includes PIKE Technologies TempPRO software.
HATR and HATRPlus Liquid Jacketed, Flow-Through Crystal PlatesPA R T NUMB E R D E S C R I P T I O N
022-5410 HATR Liquid Jacketed Flow-Through Plate, ZnSe, 45°
022-5420 HATR Liquid Jacketed Flow-Through Plate, AMTIR, 45°
022-5430 HATR Liquid Jacketed Flow-Through Plate, KRS-5, 45°
022-5440 HATR Liquid Jacketed Flow-Through Plate, Si, 45°
022-5450 HATR Liquid Jacketed Flow-Through Plate, Ge, 45°
Notes: Liquid jacketed flow-through crystal plates require customer provided circulating water bath. Liquid jacketed flow-through crystal plates enable heatingto 130 °C and cooling. HATR flow cells include Luer-Lok fittings for easy connectionwith a syringe. A set of 1/16" Swagelok® fittings are included with each flow cell forconnection with 1/16" tubing.
HATR RCPlatePA R T NUMB E R D E S C R I P T I O N
022-2300 RCPlate for HATR (for 45° crystals)
Notes: Requires a selection of HATR Crystal – see below.
HATR and HATRPlus Replacement PartsPA R T NUMB E R D E S C R I P T I O N
022-3051 HATR Volatiles Cover
022-3052 HATR Powder Press
022-3110 Crystal, 45°, Trap, 80 x 10 x 4 mm ZnSe
022-3111 Crystal, 45°, Trap, 80 x 10 x 4 mm KRS-5
022-3112 Crystal, 45°, Trap, 80 x 10 x 4 mm Ge
022-3113 Crystal, 45°, Trap, 80 x 10 x 4 mm AMTIR
022-3114 Crystal, 45°, Trap, 80 x 10 x 4 mm Si
022-3130 Crystal, 60°, Trap, 80 x 10 x 4 mm ZnSe
022-3132 Crystal, 60°, Trap, 80 x 10 x 4 mm Ge
022-3040 Viton O-Ring, HATR Flow Cell, Upper (6 ea.)
022-3045 Viton O-Ring, HATR Flow Cell, Lower (6 ea.)
022-3041 Perfluoroelastomer O-Ring, HATR Flow Cell, Upper (1 ea.)
022-3046 Perfluoroelastomer O-Ring, HATR Flow Cell, Lower (1 ea.)
Notes: Please contact PIKE Technologies for items not described in this list.Reconditioning service for used HATR crystal plates is available.
RES IST IVELY HEATED HATR PLATES SPEC IF ICAT IONS
Temperature Range Ambient to 130 °C
Accuracy +/- 0.5%
Sensor Type 3 wire Pt RTD (low drift, high stability)
Controllers
Digital +/- 0.5% of set point
Digital PC +/- 0.5% of set point, graphical setup, upto 10 ramps, USB interface
Input Voltage 90–264 V, auto setting, external power supply
Output Voltage 24 VDC/50 W maximum
02_ATR 12-13-12_02_ATR 12/13/12 1:14 PM Page 20
21
ATTENUATED
TOTAL
REFLECTANCE
– L
IQ
UI
DS
, SO
LI
DS
AN
DI
N-B
ET
WE
EN
ATRMax II Variable Angle Horizontal ATR Accessory – HATR for Inquisitive Minds
The ATRMax II is a high throughput, variable angle horizontal ATRaccessory developed for use in FTIR spectrometers. The designemploys a unique optical layout (U.S. patent 5,105,196) whichenables samples to be analyzed over a range of incident angles(from 25 to 65 degrees). Variable angle of incidence providesexperimental control over the depth of penetration of an IRbeam into the sample and the number of beam reflections in the ATR crystal, which in turn determines the effective IR beampathlength for a given experiment. Adjustable angle of incidenceallows immediate optimization of measurements for otherwisedifficult to analyze samples. The ATRMax can be used for depthprofiling studies where spectral composition can be analyzed relative to depth of penetration as the angle of incidence is changed.
Two crystal configurations, flat plate and trough plate, areavailable for the ATRMax II. The flat plate design is used for theanalysis of coatings, films and solids. Typical applications includedepth profiling studies and optimization of ATR spectral data. A sample clamp is required to provide intimate contact betweenthe sample and crystal surface.
F E ATUR E S O F THE ATRMAX I I
• Selectable angle of incidence – 20 to 70 degrees in onedegree increments
• 0.5 to 10 micron depth of penetration – dependent on crystalmaterial, angle of incidence, sample’s refractive index andwavelength of IR beam – ideal for depth profiling studies
• 3 to 12 reflections of IR beam – dependent upon angle of incidence – ideal for optimizing ATR sampling methods
• Flat and trough crystal plates for solids, films, powders andliquid samples – optional temperature control for all plates
• Optional, high-pressure clamp for sampling of films, coatings or powdered samples
• Motorized option with electronic control module and AutoPRO™software for automated, high-precision experiments
• Sealed and purgeable optical design to eliminate watervapor and carbon dioxide interferences
Depth profiling study of silicon release agent using ATRMax II accessory.FTIR spectra collected using Ge crystal flat plates at effective angles ofincidence from 25 to 65 degrees.
Proprietary beam path within the ATRMax II FTIR sampling accessory.
02_ATR 12-13-12_02_ATR 12/13/12 1:14 PM Page 21
PIK
ET
EC
HN
OL
OG
IES
WW
W.
PIK
ET
EC
H.
CO
M6
08
-27
4-2
72
1
22
The trough crystal plate is recommended for use with liquids,pastes and powdered samples. Typical applications include theanalysis of oils, detergents, and other liquid samples. A volatilescover and powder press are included with the ATRMax II for usewith this crystal mount.
The ATR crystals for the ATRMax II are of trapezoidal shapeand 56 mm long, 10 mm wide and 4 mm thick. Standard bevelangles at each end of the crystal are available in 30, 45, and 60degree versions. Coupling the variable angle of incidence of theATRMax II with the variable crystal face angles, one can selecteffective angle of incidence ranging from 25 to 65 degrees andthe range in number of reflections from 3 to 12.
The variable angle of incidence can be controlled manuallyor with an optional motorized attachment for the ATRMax II.Multiple ATR measurements at different angles of incidence canbe fully automated with the motorized version and PIKE TechnologiesAutoPRO software. Automation streamlines the collection of spectra from multiple angles of incidence. With the automatedATRMax accessory, the entire experiment can be pre-programmedand executed by the computer.
Advantages of the automated ATRMax II system include:
• Computer controlled precision, accuracy and repeatability
• Synchronization of mirror position changes with collection of sample spectra
• Full integration of the PIKE Technologies AutoPRO software withFTIR spectrometer programs
• Tailor made, predefined experiments
• “Hands-free” operation
Optimized FTIR spectrum of polymer film run with the ATRMax II at 60 degree angle of incidence.
Liquid cough syrup sample run with the ATRMax II accessory using theZnSe trough plate and a 40 degree angle of incidence.
AutoPRO Software control ofATRMax angle of incidence(automated polarizer available)for automated depth profilingstudies and ATR experimentoptimization.
Optional resistively heated crystalplates are available for the ATRMax IItrough, flat and flow cell versions.These heated crystal plates are drivenusing PIKE Technologies TemperatureControllers available in digital anddigital PC versions. The digital PC version includes PIKE TempPRO soft-ware for graphical setup and datacollection for kinetic experiments.
Ambient temperature and liquid-jacketed flow cells are available forthe ATRMax II. With the liquid-jacketedversion one can measure samples atheated or cooled temperatures usinga circulating water bath.
ATRMax II RCPlate
For special applications where you need to look at coatingson an ATR crystal, PIKE Technologies offers the RCPlate™ option.The new RCPlate is designed to enable easy removal and reinsertionof the ATR crystal. Applications include analysis of coatings,mono-molecular layers, or bio-films deposited directly upon the ATR crystal. With these new RCPlates, it is easy to collect the background spectrum on the clean crystal, remove the ATR crystalfrom the RCPlate, coat the crystal and then reposition it into theRCPlate to collect the sample spectrum.
02_ATR 12-13-12_02_ATR 12/13/12 1:14 PM Page 22
23
ATTENUATED
TOTAL
REFLECTANCE
– L
IQ
UI
DS
, SO
LI
DS
AN
DI
N-B
ET
WE
EN
ATRMax II System ConfigurationsPART NUMBER D E S C R I P T I O N
023-10XX ATRMax II Trough Plate System with 45º ZnSe CrystalIncludes: Trough Plate, Volatiles Cover and Powder Press
023-11XX ATRMax II Flat Plate System with 45º ZnSe CrystalIncludes: Flat Plate and HATR Pressure Clamp
023-12XX ATRMax II Combined Trough and Flat Plate System with 45º ZnSe CrystalsIncludes Trough Plate, Flat Plate, Volatiles Cover, Powder Press and Sample Clamp
Notes: ATRMax II Systems may be purchased with crystal plates other than ZnSe.Just add – Ge for germanium, -KR for KRS-5, -AM for AMTIR, or – Si for Silicon.Additional plates can be added to an order for any system above. Other configurationsmay be selected from the options below.
ATRMax II Base Optics (must select, insert spectrometer model for XX)PART NUMBER D E S C R I P T I O N
023-19XX ATRMax II Variable Angle HATR
Notes: ATRMax II Base Optics includes volatiles cover, powder press, purge tubes,purge kit and spectrometer base mount.
ATRMax II Crystal Plates (must select 1 or more)PART NUMBER D E S C R I P T I O N
023-2001 Trough Plate, ZnSe, 45°
023-2011 Flat Plate, ZnSe, 45°
023-2021 Trough Plate, ZnSe, 30°
023-2031 Flat Plate, ZnSe, 30°
023-2041 Trough Plate, ZnSe, 60°
023-2051 Flat Plate, ZnSe, 60°
023-2003 Trough Plate, Ge, 45°
023-2013 Flat Plate, Ge, 45°
023-2023 Trough Plate, Ge, 30°
023-2033 Flat Plate, Ge, 30°
023-2043 Trough Plate, Ge, 60°
023-2053 Flat Plate, Ge, 60°
023-2046 Trough Plate, AMTIR, 45°
023-2047 Flat Plate, AMTIR, 45°
023-2002 Trough Plate, KRS-5, 45°
023-2012 Flat Plate, KRS-5, 45°
023-2022 Trough Plate, KRS-5, 30°
023-2032 Flat Plate, KRS-5, 30°
023-2042 Trough Plate, KRS-5, 60°
023-2052 Flat Plate, KRS-5, 60°
023-2044 Trough Plate, Si, 45°
023-2045 Flat Plate, Si, 45°
Notes: ATRMax Crystal Plates are pre-aligned and pinned-in-place. Changing crystalplates is easy and fast to optimize sampling results. If you need a crystal plate notlisted here, please contact us.
ATRMax II Pressure ClampPA R T NUMB E R D E S C R I P T I O N
023-3050 ATRMax Pressure Clamp
Notes: The pressure clamp is required for solids, films, coatings and powdered samples.
ATRMax II Sampling OptionsPART NUMBER D E S C R I P T I O N
023-2800 Motorized Upgrade for ATRMax II
023-2850 Motorized Option for ATRMax II
090-1000 Manual Polarizer, ZnSe
090-2000 Automated Polarizer, ZnSe
023-2300 RCPlate for ATRMax II
023-4000 ATRMax Flow Cell Assembly (Order crystal separately)
023-4100 ATRMax Liquid-Jacketed Flow Cell Assembly (Order crystal separately)
023-4200 ATRMax Heated Flow Cell Assembly (Order crystal separately)
023-4300 ATRMax Heated Trough Plate Assembly (Order crystal separately)
023-4400 ATRMax Heated Flat Plate Assembly (Order crystal separately)
013-4200 ATR Variable Angle Heating Conversion Plate
076-1420 Digital Temperature Control Module, PC Control
076-1220 Digital Temperature Control Module
Notes: Motorized Option includes PIKE Technologies AutoPRO software and controller.Other polarizer options are found in the polarization section of this catalog. TheATR Variable Angle Heating Conversion Plate must be selected with temperaturecontrolled crystal plates. Resistively heated crystal plates require selection of theTemperature Control Module. Maximum crystal temperature is 120 °C.
ATRMax II CrystalsPART NUMBER D E S C R I P T I O N
023-3110 Crystal, 45°, Trap., 56 x 10 x 4, ZnSe
023-3130 Crystal, 60°, Trap., 56 x 10 x 4, ZnSe
023-3120 Crystal, 30°, Trap., 56 x 10 x 4, Ge
023-3112 Crystal, 45°, Trap., 56 x 10 x 4, Ge
023-3132 Crystal, 60°, Trap., 56 x 10 x 4, Ge
023-3121 Crystal, 30°, Trap., 56 x 10 x 4, Si
023-3114 Crystal, 45°, Trap., 56 x 10 x 4, Si
023-3134 Crystal, 60°, Trap., 56 x 10 x 4, Si
023-3113 Crystal, 45°, Trap., 56 x 10 x 4, AMTIR
023-3133 Crystal, 60°, Trap., 56 x 10 x 4, AMTIR
Notes: Please contact PIKE Technologies for crystals not on this list.
ATRMax II Replacement PartsPART NUMBER D E S C R I P T I O N
023-3051 ATRMax II Volatiles Cover
023-3052 ATRMax II Powder Press
Notes: Please contact PIKE Technologies for items not described in this list.Reconditioning service for used ATRMax crystal plates is available.
ORDER I NG IN FORMAT I ON
RES IST IVELY HEATED ATRMAX I I PLATES SPEC IF ICAT IONS
Temperature Range Ambient to 120 °C
Accuracy +/- 0.5%
Voltage 24 VDC
Sensor Type 3 wire Pt RTD (low drift, high stability)
Controller
Digital +/- 0.5% of set point
Digital PC +/- 0.5% of set point, graphical setup, up to 10 ramps, USB interface
Input Voltage 90–264 V, auto setting, external power supply
Operating Voltage 24 VDC/36 W
02_ATR 12-13-12_02_ATR 12/13/12 1:14 PM Page 23
PIK
ET
EC
HN
OL
OG
IES
WW
W.
PIK
ET
EC
H.
CO
M6
08
-27
4-2
72
1
24
VeeMAX III with ATR – Variable Angle, Single Reflection ATR for Depth Profiling Studies
The VeeMAX III with ATR offers continuous variable angle of incidenceand a variety of crystal plates to selectively control the depth ofpenetration of the IR beam into the sample. ATR applicationsinclude the study of layered samples, coatings, release agents,monolayers on silicon and chemical migration studies.
The VeeMAX III with ATR accessory provides exceptionally high throughput (over 50% with 45 degree ZnSe crystal) to minimizesampling time and enable detection of low concentration compo-nents in samples of complex composition. The flat plate crystalsoffered for the VeeMAX III are ideal for solid and layered samplesand are designed for use with the optional pressure clamp. The
combination of large crystal diameter (20 mm) and slip-clutchpressure clamp provides sample to crystal contact without alteringlayered sample composition. The optional liquids retainer may beadded to the crystal plate for analysis of liquid samples.
Monolayers and ultra-thin films absorbed on silicon or goldsubstrate are easily sampled using the VeeMAX III equipped with ahigh refractive index ATR crystal. Compared to specular reflectancesampling for monolayer analysis, an increase in sensitivity of upto 1–2 orders of magnitude may be realized via ATR sampling.For these applications, the VeeMAX III accessory is configured toinclude a high-angle Ge flat plate (60° or 65°), the VeeMAX IIIhigh-pressure clamp with a 7.8 mm pressure tip, and a polarizer.
A spectroelectrochemical cell option for the VeeMAX III is alsoavailable. The innovative design offers a polytetrafluoroethylenecup sealed to an ATR crystal, which is mounted on the VeeMAX.The crystals are interchangeable for optimizing spectral resultsand are removable to allow electrode coating on the ATR surface.The high throughput of the VeeMAX with ATR provides excellentsensitivity and reduced sampling time. Additionally, a flat IRtransparent window may be installed instead to permit specularreflectance sampling. The electrochemistry cell is equipped with aprecision micrometer for electrode positioning.
F E ATUR E S O F THE V E EMAX I I I W I TH ATR
• Continuously variable set angle of incidence – 30 to 75 degrees• 0.4 to 46 micron depth of penetration – dependent on crystalmaterial, angle of incidence, sample’s refractive index andwavelength of IR beam – ideal for depth profiling studies
• High throughput for excellent quality spectra in a short time period
• Optional, high-pressure clamp for sampling of films, coatingsor powdered samples
• Integrated position for optional manual or automatedpolarization
• Motorized option with electronic control module and AutoPROsoftware for automated, high-precision experiments
• VeeMAX III can be used as a variable angle of incidence specular reflection accessory
• Configurable for specialized applications – monolayer studiesand spectroelectrochemistry
• Sealed and purgeable optical design to eliminate watervapor and carbon dioxide interferences
Depth profiling study of layered polymer film. FTIR spectra collectedusing ZnSe crystal at set angles of incidence from 43 to 65 degrees. IR absorbance band at 1591 cm-1 clearly increases relative to otherbands as we probe deeper into the sample.
Analysis of monomolecular layer on silicon – VeeMAX III with 60 degreeGe crystal, pressure clamp with 7.8 mm tip and p polarization.
02_ATR 12-13-12_02_ATR 12/13/12 1:14 PM Page 24
25
ATTENUATED
TOTAL
REFLECTANCE
– L
IQ
UI
DS
, SO
LI
DS
AN
DI
N-B
ET
WE
EN
Motorized control of angle of incidence via personal computerfor automated data collection of depth profiling studies and ATRmeasurements is available for the accessory. The motorizedVeeMAX III is ideal for depth profiling studies as it greatly speedsand improves the precision and reproducibility of the data collection process.
Spectroelectrochemical cell with removable and interchangeable crystalsmounted on the VeeMAX
VeeMAX spectroelectrochemical cell offers maximum flexibility by itsinterchangeable and removable crystals
AutoPRO Software controlof VeeMAX III angle of incidence (automatedpolarizer available) forautomated depth profilingstudies, angle of incidenceand polarization anglecan be set independently.
Heated crystal plates are availablefor the VeeMAX III for TemperatureStudies
TempPRO software for graphical setup and control of kinetic measurements
VEEMAX I I I WITH ATR SPEC IF ICAT IONS
ATR Crystal Choice ZnSe, Ge, Si, ZnS
Crystal Plate Mounting User changeable plates
Crystal Plate Mounts Stainless Steel
Crystal Dimension, Surface 20 mm diameter
Optics All reflective
Pressure Device Rotating, continuous variable pressure; click stop at maximum
Heating Options 130 °CAccuracy +/- 0.5%Sensor Type 3 wire Pt RTD (low drift, high stability)Temperature Control Digital or digital with PC control (up to 10 ramps,
automated data collection, USB interface)Input Voltage 100–240 VAC, auto setting, external
power supply
Operating Voltage 24 VDC/50 W
Purge Sealing Purge tubes and purge barb included
Accessory Dimensions 177 x 92 x 162 mm (excludes clamp (W x D x H) height and baseplate)
Spectroelectrochemical Vessel Dimensions 19 mm diameter tapering to 25 mm, 25 mm tall
Spectroelectrochemical Vessel Volume 7.5 mL
Spectroelectrochemical Vessel Material Polytetrafluoroethylene
FTIR Compatibility Most, specify model and type
Temperature controlled crystal plates are available for thermalstudy of materials. PIKE Technologies offers temperature controllerswith digital and PC programmable set points.
VeeMAX withATR opticallayout
02_ATR 12-13-12_02_ATR 12/13/12 1:14 PM Page 25
PIK
ET
EC
HN
OL
OG
IES
WW
W.
PIK
ET
EC
H.
CO
M6
08
-27
4-2
72
1
26
VeeMAX III Pressure Clamp (must select for solids, films or powder analysis)PA R T NUMB E R D E S C R I P T I O N
013-3101 VeeMAX III ATR Pressure Clamp
025-3094 7.8 mm ATR Pressure Tip
Notes: Pressure clamp supplied with 20 mm tip for polymer films. The 7.8 mm pressuretip is required for monolayers on silicon or small samples. The pressure clamp isrequired for solids, films, coatings and powdered samples.
VeeMAX III Sampling OptionsPA R T NUMB E R D E S C R I P T I O N
013-2851 Motorized Option for VeeMAX III
013-2801 Motorized Upgrade for VeeMAX III
090-1000 Manual Polarizer, ZnSe
090-1200 Manual Polarizer, KRS-5
090-3000 Precision Manual Polarizer, ZnSe
090-3200 Precision Manual Polarizer, KRS-5
090-4000 Precision Automated Polarizer, ZnSe
090-4200 Precision Automated Polarizer, KRS-5
007-0300 PIKECalc Software
Notes: PIKECalc software provides easy calculations of depth of penetration, effectiveangle of incidence and critical angle for ATR measurements. Motorized Option includesPIKE Technologies AutoPRO software and controller. Other polarizer options arefound in the polarization section of this catalog. Motorized VeeMAX III andAutomated polarizer interface simultaneously with the same controller.
Spectroelectrochemical ConfigurationPA R T NUMB E R D E S C R I P T I O N
013-3300 Electrochemical Cell
013-3110 ZnSe Crystal, 45°
013-3130 ZnSe Crystal, 60°
013-3112 Ge Crystal, 45°
013-3132 Ge Crystal, 60°
013-3114 Si Crystal, 45°
013-3134 Si Crystal, 60°
013-3115 ZnS Crystal, 45°
013-3135 ZnS Crystal, 60°
160-1144 CaF2 Flat Window, 20 mm diameter
160-1304 ZnSe Flat Window, 20 mm diameter
013-3345 45° Crystal Holder
013-3360 60° Crystal Holder
Notes: The electrochemical configuration requires electrochemical cell and theVeeMAX III Specular Reflectance Accessory. Must select one or more crystals. Choose aCrystal Holder to match the crystal angle. A CaF2 window may be used for specularreflectance sampling. Other window types for specular reflectance measurementsmay be found in our listing of transmission windows, 20 mm x 2 mm. Either alignment fixture is applicable for mounting a flat window. Electrodes supplied bythe end-user.
Replacement PartsPA R T NUMB E R D E S C R I P T I O N
013-4010 Mask Set for VeeMAX
ORDER I NG IN FORMAT I ON
VeeMAX III Base Optics (must select, insert spectrometer model for XX)PA R T NUMB E R D E S C R I P T I O N
013-11XX VeeMAX III Variable Angle Specular Reflectance Accessory
Notes: VeeMAX III includes specular reflectance masks (2", 5/8" and 3/8"), purge tubes,purge kit and spectrometer base mount. Please see the FTIR instrument code sheet.
VeeMAX III ATR Crystal Plates (must select 1 or more for ATR)PA R T NUMB E R D E S C R I P T I O N
013-4021 Flat Plate, ZnSe, 45°
013-4031 Flat Plate, ZnSe, 60°
013-4041 Flat Plate, Ge, 45°
013-4051 Flat Plate, Ge, 60°
013-4061 Flat Plate, Ge, 65°
013-4081 Flat Plate, Si, 45°
013-4071 Flat Plate, Si, 60°
013-4091 Flat Plate, ZnS, 45°
013-4096 Flat Plate, ZnS, 60°
013-3401 Liquids Retainer for VeeMAX III ATR crystals
013-3501 VeeMAX III ATR Flow Cell
Notes: VeeMAX III Crystal Plates are pre-aligned and pinned-in-place. Changing crystal plates is easy and fast to optimize sampling results. ZnS crystal plate isexcellent for deepest penetration of IR beam. Si crystal plate is excellent for Far IR ATR. If you need a crystal not listed here, please contact us. Reconditioningservice for used VeeMAX crystal plates is available.
Heated VeeMAX III ATR Crystal Plates (optional)PA R T NUMB E R D E S C R I P T I O N
013-4121 Heated Flat Plate, ZnSe, 45°
013-4131 Heated Flat Plate, ZnSe, 60°
013-4141 Heated Flat Plate, Ge, 45°
013-4151 Heated Flat Plate, Ge, 60°
013-4161 Heated Flat Plate, Ge, 65°
013-4171 Heated Flat Plate, Si, 60°
013-4181 Heated Flat Plate, Si, 45°
013-4191 Heated Flat Plate, ZnS, 45°
013-4196 Heated Flat Plate, ZnS, 60°
076-1220 Digital Temperature Control Module
076-1420 Digital Temperature Control Module, PC Control
Notes: Heated VeeMAX crystal plates may be heated to 130 °C. A temperature controller must be selected.
02_ATR 12-13-12_02_ATR 12/13/12 1:14 PM Page 26
27
ATTENUATED
TOTAL
REFLECTANCE
– L
IQ
UI
DS
, SO
LI
DS
AN
DI
N-B
ET
WE
EN
JetStream ATR Accessory – Measurements of Liquids under Varying Conditions
The PIKE Technologies JetStream is a unique ATR accessory optimizedfor analysis of liquids in static or flow modes at varying pressure.The accessory design revolves around a cylindrical ATR crystalthat is encased in a heavy-duty stainless steel body. The sample is introduced via a Swagelok® (from 1/16" up to 1/4" tube OD)connection and completely surrounds the ATR crystal providingefficient sampling, excellent reproducibly and sufficient throughputfor high sensitivity measurements.
The compact cell design employs a pair of transfer optics todirect the infrared beam to one end of an IR transmitting ATRcrystal. A similar pair of optics directs the beam emitted from theother end of the ATR crystal to the spectrometer detector.
The ATR crystal for the JetStream ATR accessory is of a cylindrical shape and is 82 mm long and 6.4 mm in diameter.The volume of the sample chamber is 1.3 mL.
To optimize accessory performance, crystal geometry hasbeen carefully chosen. The design of the JetStream ATR accessoryprovides 12 reflections of the IR beam along the crystal surface.
The maximum pressure rating is 1500 psig. The accessory fitsin most brands of FTIR spectrometers.
F E ATUR E S O F THE J E T S T R E AM ATR AC C E S S ORY
• Efficient ATR design for static and flowing liquid measurements• Small sample chamber provides efficient sampling• ZnSe and Germanium crystal options to match samplerequirements
• Qualitative and quantitative applications
ORDER I NG IN FORMAT I ON
JetStream ATR (insert spectrometer model for XX)PA R T NUMB E R D E S C R I P T I O N
020-19XX JetStream ATR Base Optics Assembly
Notes: Contact PIKE Technologies for temperature control options
ATR Crystals (must select one)PA R T NUMB E R D E S C R I P T I O N
020-2010 ZnSe Rod
020-2050 Ge Rod
Replacement PartsPA R T NUMB E R D E S C R I P T I O N
020-3040 EPDM Crystal O-Rings (2 each)
020-3041 EPDM Housing O-Rings (2 each)
020-3045 Kalrez Crystal O-Rings (2 each)
020-3046 Kalrez Housing O-Rings (2 each)
J ETSTREAM ATR ACCESSORY SPEC IF ICAT IONS
Cell Body 316 Stainless Steel
ATR Crystals ZnSe or Germanium
Crystal Size 82 mm x 6.4 mm
Crystal Face Angle 45°
Number of Reflections 12
Cell Volume 1.3 mL
Liquid Connectors 316 Stainless Steel Swagelok®
Maximum Pressure 1500 psig
Optical diagram of the JetStream ATR
Isopropanol spectrum collected using the JetStream with ZnSe crystal
02_ATR 12-13-12_02_ATR 12/13/12 1:14 PM Page 27
PIK
ET
EC
HN
OL
OG
IES
WW
W.
PIK
ET
EC
H.
CO
M6
08
-27
4-2
72
1
28
Classic VATR – Variable Angle ATR for Analysis of Solids, Films and Coatings
The Variable Angle ATR, is a traditional in-compartment accessorywith the ATR crystal mounted vertically with respect to the spec-trometer baseplate. Its optical layout is based on an optimizedGilby configuration and allows continuous adjustment of the incident beam angle between 30 to 60 degrees. This accessory is suitable for the analysis of solids, films and coatings, but for obvious reasons, it cannot be used for working with liquids. Forenhanced sensitivity the sample may be mounted on both sidesof the crystal. A unique mirror adjustment mechanism which utilizes mirror placement and proportional pivoting allows precise and repeatable alignment. The PIKE Technologies VariableAngle ATR offers flexibility when the frequent replacement of ATR crystals is required. VATR is an excellent, low-cost tool forteaching the principles of internal reflection spectroscopy, and for basic research.
F E ATUR E S O F THE C L A S S I C VATR
• 30º to 60º – continuously variable angle of incidence • Full control over the number of reflections and depth of penetration
• Unique mechanism for fine-tuning mirror positions and precise and repeatable alignment
• High energy throughput • Stainless steel, easy to remove crystal mounts and anvils• Economical introduction to ATR techniques – excellent R&D and teaching tool
ORDER I NG IN FORMAT I ON
VATR Base Optics (must select, insert spectrometer model for XX)PA R T NUMB E R D E S C R I P T I O N
021-19XX VATR Variable Angle, Vertical ATR
Notes: VATR Base Optics includes plate for mounting in FTIR spectrometer slide mount.
VATR Crystal Options (must select 1 or more)P /N 5 0 MM DE S C R I P T I O N P /N 2 5 MM
021-4000 KRS-5, 45° Parallelogram 021-4020
021-4010 KRS-5, 60° Parallelogram 021-4030
021-4040 ZnSe, 45° Parallelogram 021-4050
021-4150 ZnSe, 60° Parallelogram 021-4120
021-4130 Ge, 30° Parallelogram 021-4100
021-4060 Ge, 45° Parallelogram 021-4080
021-4070 Ge, 60° Parallelogram 021-4090
021-4160 Si, 45° Parallelogram 021-4110
Notes: VATR crystals are available in 25 mm and 50 mm lengths – all are 3 mm thick and 10 mm wide. Select crystal length and type based upon desiredsample absorbance.
VATR Crystal Holder and Clamp (must select 1 or more to hold ATR crystals)PA R T NUMB E R D E S C R I P T I O N
021-5050 50 mm VATR Crystal Holder and Clamp
021-5020 25 mm VATR Crystal Holder, Clamp and Mirror
Notes: The pressure clamp is selected for the ATR crystal length.
VATR Replacement PartsPA R T NUMB E R D E S C R I P T I O N
021-5040 25 mm VATR Crystal Holder and Clamp
021-5030 Set of 25 mm and 50 mm Pads
Notes: Please contact PIKE Technologies for items not described in this list.
02_ATR 12-13-12_02_ATR 12/13/12 1:14 PM Page 28
29
ATTENUATED
TOTAL
REFLECTANCE
– L
IQ
UI
DS
, SO
LI
DS
AN
DI
N-B
ET
WE
EN
ATR – Theory and ApplicationsAttenuated Total Reflectance (ATR) is today the most widely usedFTIR sampling tool. ATR generally allows qualitative or quantitativeanalysis of samples with little or no sample preparation, whichgreatly speeds sample analysis. The main benefit of ATR samplingcomes from the very thin sampling pathlength and depth of penetration of the IR beam into the sample. This is in contrast totraditional FTIR sampling by transmission where the sample mustbe diluted with IR transparent salt, pressed into a pellet or pressed toa thin film, prior to analysis to prevent totally absorbing bands inthe infrared spectrum.
A comparison of transmission versus ATR sampling results fora thick polymer sample is shown below where the sample is toothick for high quality transmission analysis (shown in the lowerblue spectrum). In transmission spectroscopy, the IR beam passesthrough the sample and the effective pathlength is determined bythe thickness of the sample and its orientation to the directionalplane of the IR beam. Clearly in the example below the sample istoo thick for transmission analysis because most of the IR bandsare totally absorbing.
However, simply placing the thick sample on the ATR crystal(Diamond MIRacle) and applying pressure generates a nearly perfect result (upper red spectrum) – identified by library searchas a polybutylene terephthalate. The total analysis time for thethick polymer by ATR was less than 1 minute.
How ATR WorksWith ATR sampling we direct the IR beam into a crystal of relativelyhigher refractive index. The IR beam reflects from the internalsurface of the crystal and creates an evanescent wave, which projects orthogonally into the sample in intimate contact with the ATR crystal. Some of the energy of the evanescent wave isabsorbed by the sample and the reflected radiation (some nowabsorbed by the sample) is returned to the detector. This ATRphenomenon is shown graphically in the following representationof a single reflection ATR.
While the analysis of samples by ATR is easy, it is interestingand useful to be aware of each of the following experimental factors and how they affect the final spectrum:
• Refractive indices of the ATR crystal and the sample
• Angle of incidence of the IR beam
• Critical angle
• Depth of penetration
• Wavelength of the IR beam
• Effective pathlength
• Number of reflections
• Quality of the sample contact with ATR crystal
• ATR crystal characteristics
The refractive indices of the crystal and sample are importantconsiderations in the ATR sampling technique by virtue of the following equation,
where n2 is the refractive index of the sample, n1 is the refractiveindex of the crystal and θc is the critical angle.
When we exceed the critical angle, we will observe a purelyATR spectral result. If the critical angle is not met, we will observea combined ATR and external reflectance result. This occurs if theangle of incidence of the IR beam is too low, if the refractiveindex of the crystal is too low, if the refractive index of the sampleis too high or a combination of these 3 factors. In most cases thisproblem is not observed, however, an example of this is shown inthe following spectral data for your reference. The sample is ahigh refractive index liquid (n=1.8) run on a 45 degree accessoryusing diamond and Ge crystal plates. The spectrum run on the Ge crystal plate exhibits a normal baseline and symmetricabsorbance bands – critical angle is met. The spectrum run onthe diamond crystal plate has a baseline shifted and asymmetricabsorbance bands due to non-adherence to the critical anglerequirements for this set of analysis parameters.
Another way to correct the spectral artifacts observed (above) inthe high refractive index sample spectrum would be to increasethe angle of incidence in the ATR accessory to a value above thecritical angle. Adjustment or selection of the angle of incidence isavailable in several of the PIKE Technologies ATR accessories.
ATR and Transmission Spectra of a Thick Polymer Sample
Graphical Representation of a Single Reflection ATR
Spectra of High Refractive Index Liquid using Ge (upper red) andDiamond (lower blue) ATR Crystals
02_ATR 12-13-12_02_ATR 12/13/12 1:14 PM Page 29
PIK
ET
EC
HN
OL
OG
IES
WW
W.
PIK
ET
EC
H.
CO
M6
08
-27
4-2
72
1
30
Further useful consideration for ATR analysis is the depth ofpenetration (dp) of the IR beam into the sample. Technically, thisis defined as the distance required for the electric field amplitudeto fall to e-1 of its value at the surface and is further defined by:
where λ is the wavelength of light and θ is the angle of incidenceof the IR beam relative to a perpendicular from the surface of thecrystal. Typical depth of penetration in ATR ranges from about 0.5microns up to about 5 microns depending upon these experimentalconditions. Shown in the graphical representation of the ATR phenomenon, the strength of the evanescent wave decays rapidlyas we progress from the surface of the ATR crystal. If we wish tocompare the sample absorbance of the ATR measurement withthat of a transmission measurement, we need to calculate thevolume of the evanescent wave, known as the effective penetrationof the IR beam. The effective penetration (de), is unique for parallelpolarization (deII) and perpendicular polarization (d⊥) and theseare defined by:
The effective penetration for an unpolarized IR beam is the average of the parallel and perpendicular penetration.
Generally, a single reflection ATR is ideal for qualitative analysis,“What is my sample?” When we need to look at minor componentsof a sample for qualitative or quantitative analysis, then we needto increase the effective path length (EPL) by increasing the numberof reflections (N) within the ATR crystal. The effective pathlengthin ATR is derived by the following equation:
An example of the benefit of increased number of reflectionsis shown in the following spectral data for the analysis of carbo-hydrate content in a soft drink sample. The upper red spectrum isrun using a 10 reflection HATR accessory. The lower blue spectrumis run using a single reflection ATR using an identical scaling factor. Clearly the minor carbohydrate bands are more readilyapparent in the multi-reflection ATR accessory.
For your convenience we have calculated theoretical valuesof depth of penetration, effective penetration, and effective pathlength for typical combinations of crystal materials, angles of incidence, and number of reflections shown in Table 1.
With the thin penetration of the evanescent wave into thesample, it is obvious that intimate contact of the sample be madeonto the surface of the ATR crystal. For liquid or pliable samples,quality of sample contact with the ATR crystal is generally nota problem. For rigid, irregular shaped or porous samples, high pressure sufficient to deform the sample will increase the extentof sample contact and thereby increase sample absorbance. Thisis shown in the following spectral data collected for a porousfoam polymer using a MIRacle ATR with ZnSe crystal.
Soft Drink Sample using 10 Reflection and 1 Reflection ATR
ATR Sampling ZnSe, Diamond AMTIR Ge for n2 = 1.5 n1 = 2.4 n1 = 2.5 n1 = 4.0
λ = 1000 cm-1 θc = 38.7 θc = 36.9 θc = 22.0
θ N dp de EPL dp de EPL dp de EPL
45 1 2.0 4.36 4.36 1.7 3.38 3.38 0.66 0.61 0.61
45 3 2.0 4.36 13.08 1.7 3.38 10.15 0.66 0.61 1.84
45 10 2.0 4.36 43.60 1.7 3.38 33.84 0.66 0.61 6.14
30 1 N/A N/A N/A N/A N/A N/A 1.2 1.59 1.59
30 3 N/A N/A N/A N/A N/A N/A 1.2 1.59 4.76
30 10 N/A N/A N/A N/A N/A N/A 1.2 1.59 15.85
60 1 1.11 1.53 1.53 1.02 1.30 1.30 0.51 0.32 0.32
60 3 1.11 1.53 4.59 1.02 1.30 3.91 0.51 0.32 0.97
60 10 1.11 1.53 15.32 1.02 1.30 13.03 0.51 0.32 3.23
Table 1: Pathlengths (in microns) of ATR Crystals at Various Angles of Incidence and Numbers of Reflections
02_ATR 12-13-12_02_ATR 12/13/12 1:14 PM Page 30
31
ATTENUATED
TOTAL
REFLECTANCE
– L
IQ
UI
DS
, SO
LI
DS
AN
DI
N-B
ET
WE
EN
The lower blue spectrum was collected with low pressureapplied to the foam sample, whereas the upper red spectrum isproduced with high pressure. The ATR absorbance using highpressure is about 10 times greater than with low pressure – all other sampling factors are identical. For rigid, crystalline, orhard, irregular surface samples we recommend a single reflectionDiamond MIRacle ATR because it is relatively easy to apply highpressure onto the small crystal (1.8 mm diameter) with the high-pressure clamp, producing over 10,000 PSI.
The selection of the ATR crystal characteristics should bematched to the type of samples we run. Selection can be made tocontrol depth of penetration of the IR beam, for hardness to preventcrystal damage, for desired spectral range and for acceptable pHrange for acid or caustic samples. No individual crystal type willsolve all problems, so PIKE Technologies offers a broad range ofchoices for ATR. Table 2 will give you some guidelines for selectionof your ATR crystal.
Porous Foam Sample with High Pressure (upper red) and Low Pressure(lower blue)
dp, for n2 = 1.5 Water Solubility Hardnessn1 λ = 1000 cm-1, 45 deg, microns g/100 g pH Range Kg/mm
AMTIR 2.5 1.70 Insoluble 1–9 170
Diamond/ZnSe 2.4 2.01 Insoluble 1–14 5,700
Germanium 4.0 0.66 Insoluble 1–14 550
KRS-5 2.37 2.13 0.05 5–8 40
Silicon 3.4 0.85 Insoluble 1–12 1,150
ZnS 2.2 3.86 Insoluble 5–9 240
ZnSe 2.4 2.01 Insoluble 5–9 120
Table 2: ATR Crystal Characteristics for FTIR Sampling
02_ATR 12-13-12_02_ATR 12/13/12 1:14 PM Page 31
PIK
ET
EC
HN
OL
OG
IES
WW
W.
PIK
ET
EC
H.
CO
M6
08
-27
4-2
72
1
32
NOT E S
02_ATR 12-13-12_02_ATR 12/13/12 1:14 PM Page 32
Diffuse Reflectance Diffuse reflectance is a highly sensitive technique
for the analysis of powdered and solid samples.
Typically, a sample is ground with KBr to a fine
powder and run without making pellets. Some
samples can be run directly without dilution
especially, if one is looking for minor components.
Diffuse reflectance sampling is ideally suited
to automation and PIKE offers configurations for
high throughput diffuse reflectance sampling
DiffusIR™ – Research DiffuseReflectance Applications – Optional Heat Chambers
Page 35
UpIR™ – Upward Looking DiffuseReflectance – ideal for large samples and easy sample access
Page 37
AutoDiff™ Automated Diffuse ReflectanceSampling – up to 60 samples
Page 38
X, Y Autosampler Automated Diffuse Reflectance –microtiter format
Page 39
Sampling Kits Easing Diffuse Reflectance Sample Preparation
Page 40
EasiDiff™Workhorse Diffuse Reflectance Accessory
Page 34
Diffuse ReflectanceTheory and Applications
Page 41
03_Diffuse 12-12-12_03_Diffuse 12/13/12 1:17 PM Page 33
EasiDiff – Workhorse Diffuse Reflectance Accessory
The PIKE Technologies EasiDiff is an economical, high quality diffusereflectance accessory designed to analyze a wide variety of solidsamples. It is most often used in the analysis of pharmaceuticals,illicit drugs, inorganic solids and minerals, and powdered chemicals.The EasiDiff reduces the time required to produce an infraredspectrum compared to KBr pellet techniques. Typically, a smallamount of sample (about 1%) is mixed and ground with KBr powderand the spectrum is collected.
The EasiDiff employs an elegant, high performance opticaldesign for maximum energy throughput and ease of operation.Optical components critical to achieving this performance arepermanently aligned. Focusing is achieved by bringing the sample(not the collection mirror) to the optimum position with amicrometer. A dual position sample holder permits backgroundand sample collection in a simple, two-step process.
A special version of the EasiDiff for NIR measurements (gold-coated optics) is also available.
PIK
ET
EC
HN
OL
OG
IES
WW
W.
PIK
ET
EC
H.
CO
M6
08
-27
4-2
72
1
34
FE AT U R E S O F TH E EA S ID I F F
• Pre-aligned optical components for reproducible, high quality data
• Micrometer controlled sample positioning and focusing • High energy throughput providing nanogram sensitivity • Precision slide for repeatable sample introduction and efficientcollection of background and sample spectra
• Unique sample preparation and loading kit with two macrocups, two micro cups, spatulas, aluminum mirror and necessary tools
OR D E R I N G IN F O R M AT I O N
EasiDiff Accessory (Must Select One)PA R T N U M B E R D E S C R I P T I O N
042-10XX EasiDiff Accessory with Sample Preparation KitIncludes: Two Micro Sample Cups, Two Macro Sample Cups,EasiPrep Sample Preparation Kit, Alignment Mirror, 35 mm Mortarwith Pestle and KBr Powder (100 g)
042-50XX EasiDiff Accessory, NIR Version with Gold-Coated OpticsIncludes: Two Micro Sample Cups, Two Macro Sample Cups,EasiPrep Sample Preparation Kit, Alignment Mirror, 35 mmMortar with Pestle and KBr Powder (100 g)
Notes: Replace XX with your spectrometer model from code provided on the lastpage of this catalog.
EasiDiff Options PA R T N U M B E R D E S C R I P T I O N
042-3010 Abrasion Sampling KitIncludes: Heavy Duty Sampling Tool and Stainless Steel Sample Support, 25 Diamond Abrasive Disks and 75 Silicon Carbide Abrasive Disks
Notes: Abrasion disks are disposable with each sample analysis – order additionaldisks below.
Replacement Parts and SuppliesPA R T N U M B E R D E S C R I P T I O N
042-2010 Small Sample Cup (micro: 6.0 mm diameter, 1.6 mm deep),2 per package
042-2020 Large Sample Cup (macro: 10 mm diameter, 2.3 mm deep),2 per package
042-2025 EasiDiff Sample Slide
160-8010 KBr Powder, 100 g
042-3020 Silicon Carbide Abrasive Disks (Pack of 100)
042-3025 Diamond Abrasive Disks (Pack of 50)
042-3030 Sample Cup Holder and Base
042-3040 Sample Preparation Kit
042-3080 Alignment Mirror
042-3082 Alignment Mirror, Gold
042-3060 Flat Sample Post
Notes: Please contact PIKE Technologies for items not described in this list.
A spectrum of papaverine hydrochloride (about 1% in KBr powder) wascollected using the PIKE Technologies EasiDiff diffuse reflectance accessory
03_Diffuse 12-12-12_03_Diffuse 12/13/12 1:17 PM Page 34
35
DiffusIR – Research Grade Diffuse Reflectance Accessory
The PIKE Technologies DiffusIR™ is a research grade diffusereflectance accessory with a large, efficient optical design accommodating the optional PIKE Technologies environmentalchambers. These specialized chambers can be used to study thermodynamic properties of materials, determine reactionmechanisms, perform catalytic studies and much more.
The heart of the DiffusIR is a unique monolithic ellipsoidalreflector permanentlyfixed in place – eliminating the needfor repositioning thefocus optics for sampleplacement. TheDiffusIR optical designis optimized to efficiently collect diffuse radiation generated from the sample and minimize the effects ofthe specular radiation component.
With the DiffusIR, sample introduction is performed using an integral 2 position slide – enabling background and sample spectrato be collected without loss of purge. The sample height can be optimized by using the micrometer sample focusing adjustment. In this manner the sensitivity of the accessory is maximized without
sacrificing precision. The DiffusIR comesequipped with a Sample Preparation andLoading Kit and a Sample Abrasion Kit forthe analysis of intractable samples. TheDiffusIR optics are enclosed and equippedwith purge tubes for the elimination ofatmospheric interferences.
The PIKE Technologies environmental chambers for theDiffusIR can be operated at temperatures ranging from -150 to900 ºC and at pressures up to 1500 psi. The optional chambers areeasily inserted into the DiffusIR and secured using push lock pins.
Coupling the DiffusIR and environmental chambers with thePIKE PC Controlled Temperature Module and TempPRO™ softwareprovides the ability to graphically set up the experiment with up to 10 ramps and data collection initiated at specified time ortemperature intervals.
Advanced temperature studies of materials in controlled environments can be done using the PIKE environmental chambers.
A special version of the DiffusIR with gold-coated optics isavailable for maximum mid-IR performance and for NIR diffusereflectance sampling. The DiffusIR and its options are compatiblewith most FTIR spectrometers.
F E AT U R E S O F TH E D I F F U S IR
• Large, highly efficient collection optics for maximum sensitivityand detection limits
• Micrometer controlled sample focus to optimize results for every sample
• Optional environmental chambers for heating, cooling, high vacuum and high pressure applications
• Quick release feature of environmental chambers for easyinsertion and removal of sealed chambers
• Digital PC controller option for macro control of data collection at user specified temperatures or times
• Sealed and purgeable optical design to eliminate watervapor and carbon dioxide interference
PIKE Technologies TempPRO software provides a graphical interface for temperature control and kinetic measurements
Optical geometry of the DiffusIR accessory
Liquid nitrogen cooled system and temperature control module
Thermal transformation of hydrated inorganic compound measuredwith DiffusIR with environmental chamber. Spectra automatically collected between 80 and 160 ºC at 5 degree increments using PIKETempPRO software.
DIF
FU
SE
RE
FL
EC
TA
NC
E–
FROM
POWDERS
TO
PLASTICBUMPERS
03_Diffuse 12-12-12_03_Diffuse 12/13/12 1:17 PM Page 35
PIK
ET
EC
HN
OL
OG
IES
WW
W.
PIK
ET
EC
H.
CO
M6
08
-27
4-2
72
1
36
OR D E R I N G IN F O R M AT I O N
DiffusIR Accessory (must select one)PA R T N U M B E R D E S C R I P T I O N
041-10XX DiffusIR AccessoryIncludes Sample Preparation Kit with 2 micro and 2 macro sample cups, sample loading tools, Abrasion Sampling Kit,SiC and Diamond Sampling Disks, Alignment Mirror, 35 mmMortar with Pestle and KBr Powder (100 g)
041-60XX DiffusIR Accessory with Gold-Coated OpticsIncludes Sample Preparation Kit with 2 micro and 2 macro sample cups, sample loading tools, Abrasion Sampling Kit, SiC and Diamond Sampling Disks, Alignment Mirror, 35 mmMortar with Pestle and KBr Powder (100 g)
Notes: Please see the FTIR instrument code sheet.
DiffusIR Options (optional)PA R T N U M B E R D E S C R I P T I O N
162-4150 DiffusIR Environmental Chamber (HTV), ambient to 500 °C
162-4190 DiffusIR Environmental Chamber (HTV), ambient to 900 °C
162-4180 High Pressure Adaptation for Chambers (HTV)
162-4140 DiffusIR Environmental Chamber (LTV), -150 to 500 °C
Notes: DiffusIR Heated Chambers include front plate accommodating environmentalChamber (easily changeable with standard front plate), Pin-Loc Chamber insertionfor easy sample exchange, KBr window, ceramic sampling cups compatible withvacuum and reaction formats, ports and 2 shut-off valves for vacuum operation andports for connection of water cooling. The 500 °C and 900 °C HTV chambers maybe fitted with the high pressure adaption and are easily switchable from standardvacuum to high pressure operation. The LTV chamber is not compatible with simul-taneous pressurization and low temperature operation. Operation of the LTV at subambient temperatures requires customer supplied liquid chilling equipment or PN162-4160 Liquid Nitrogen Cooled System and Temperature Control Module. The HVTand LVT chambers require the selection of a temperature control module – below.
Temperature Control ModulesPA R T N U M B E R D E S C R I P T I O N
076-2420 PC Controlled Temperature Module, HTV ChambersIncludes Digital Temperature Selection and TempPROSoftware with Integrated Data Collection
076-2220 Digital Temperature Control Module, HTV Chambers
162-4160 Liquid Nitrogen Cooled System and Temperature ControlModule DiffusIR Environmental Chamber (LTV) -150 to 500 °C
076-2430 PC Controlled Temperature Module, LTV ChambersIncludes Digital Temperature Selection and TempPROSoftware with Integrated Data Collection
076-2230 Digital Temperature Control Module, LTV Chambers
Notes: PC Controlled Temperature Module with TempPRO software provides agraphical user interface for setting experiment parameters and data collection.Please contact PIKE for PC compatibility. The Temperature Control Modules for theHTV and LTV chambers are not interchangeable. 076-2430 and 076-2230 do notinclude cooling system.
Replacement Parts and SuppliesPA R T N U M B E R D E S C R I P T I O N
170-1000 Liquid Recirculator
042-2010 Small Sample Cup (micro: 6.0 mm diameter, 1.6 mm deep), 2 per package
042-2020 Large Sample Cup (macro: 10 mm diameter, 2.3 mm deep), 2 per package
042-3020 Silicon Carbide Abrasive Disks (Pack of 100)
042-3025 Diamond Abrasive Disks (Pack of 50)
042-3030 Sample Cup Holder and Base
160-8010 KBr Powder, 100 g
042-3040 Sample Preparation Kit
042-3010 Abrasion Sampling Kit
042-3060 Flat Sample Post
042-3080 Alignment Mirror
Replacement Parts and Supplies (cont.)PA R T N U M B E R D E S C R I P T I O N
160-1132 32 x 3 mm KBr Disk
160-1113 32 x 3 mm ZnSe Disk
160-5049 32 x 3 mm SiO2 Disk
160-5125 32 x 3 mm SiO2 Disk, low OH
160-1159 32 x 3 mm Si Disk
162-4210 O-Ring, DiffusIR Chamber, (Pack of 10)
162-4215 O-Ring, DiffusIR Chamber Cooling Line, (Pack of 10)
162-4251 Ceramic Cup, DiffusIR Chamber, porous
162-4270 Alignment Mirror, DiffusIR Chamber
042-3082 Alignment Mirror, Gold
Notes: Please contact PIKE Technologies for items not described in this list.
DIFFUSIR SPEC IF ICAT IONS
Optical Design 3X ellipsoidal
Angle of Incidence 30 degrees, nominal
Dimensions (W x D x H) 180 x 230 x 130 mm (excluding purge tubesand base plate)
Sample Focus Micrometer
Sample Positions 2 positions, slide stops for background and sample with no purge loss
Sample Cups Macro: 10 x 2.3 mm deepMicro: 6 x 1.6 mm deep
Purge Standard purge tubes and purge connection
DIFFUSIR ENVIRONMENTAL CHAMBER SPEC IF ICAT IONS
Temperature Range HTV Ambient to 500 or 900 °C
Temperature Range LTV -150 to 500 °C
Accuracy +/- 0.5%
Input Voltage 100–240 VAC (HTV version)110/220 V switchable (LTV version)
Operating Voltage 24 VDC/84 W (HTV version)48 VAC/100 W max. (LTV version)
Temperature Control Digital or Digital PC
Heating Rate, Maximum 120 °C/minute
Kinetic Setup • Up to 10 temperature ramps(requires Digital • Individual ramp rate and hold PC Controller, time settingsincludes PIKE • Graphical display of experiment settingsTempPRO software) • Trigger data collection at specified times
or temperatures• USB interface
Sensor K Type (for HTV)RTD Type, Pt100 (for LTV)
Vacuum Achievable 1 x 10-6 Torr (13 x 10-4 Pa)
Window Size 32 x 3 mm disk (vacuum)32 mm ZnSe dome (pressure)
Leaking Volume < 6.0 x 10-11 Pa m3/sec
Pressure Maximum • 1500 psi, with HP adaption (HTV versions only)
• 14.7 psi (1 atmosphere) without High Pressure Adaptation
Sample Cup Size 6.0 mm OD, 4.0 mm height4.7 mm ID, 2.0 mm depth
Sample Cup Design Ceramic, porous compatible with powdersand gas flow
Cooling Ports Quick-Fit, 6 mm ID
Gas/Vacuum Ports 1/8" Swagelok®
03_Diffuse 12-12-12_03_Diffuse 12/13/12 1:17 PM Page 36
UpIR – Upward Looking Diffuse Reflectance Accessory
The UpIR is an innovative FTIR accessory developed to support a wide range of diffuse reflectance applications. The UpIR isdesigned as a tall structured sampling accessory and is used by simply placing large, solid samples face down onto the top plateof the accessory. In the case of powdered or small solids, they canbe placed into a suitable sampling cup at the top of the UpIR.This design is uniquely suitable for mid-IR analysis of coatings onmetallic surfaces of large or small samples. For this application,analysis is rapid and easy because no sample preparation orcleanup is required. Since the sampling area of the UpIR is abovethe plane of the FTIR instrument, even large samples that do notfit into the sample compartment can be analyzed with this accessory.
In the NIR spectral region the UpIR is ideal for the QC analysis of powdered and tablet samples when the gold-coated optics version is selected.
The accessory is equipped with an upward-looking, high-per-formance ellipsoidal mirror which minimizes the effect of specularradiation. The sampling stage provides a sampling port with insertsfor diffuse reflectance or specular reflectance measurements.
All mirrors, including the ellipsoidal collection mirror, are per-manently mounted. The position of the sampling stage is controlledwith the adjustable micrometer to achieve the best possible through-put. Spectral analysis involves collecting a background spectrum withthe reference mirror in the sampling position. After this step, thesample is simply placed face down onto the sampling port and datacollection is initiated.
The gold-coated optics version of the UpIR provides highestthroughput in the mid-IR spectral region and is recommended forNIR sampling. The UpIR accessory includes a solids sampling plate forflat samples, and a ZnSe windowed sampling cup for powdered orsmall solids analysis. The accessory is equipped with purge tubes forelimination of CO2 and water interferences from infrared spectra.
For NIR sampling of solids, powders or tablet samples, thesapphire windowed sampling cup is recommended. In the NIRspectral region samples can be analyzed while contained in a glassvial. For this measurement, the optional 21 mm glass vial holder isrecommended.
37
DIF
FU
SE
RE
FL
EC
TA
NC
E–
FROM
POWDERS
TO
PLASTICBUMPERS
F E AT U R E S O F TH E UP IR
• Upward looking optics providing fast and easy analysis ofsamples placed face down on the UpIR sample port
• Out-of-compartment design for analysis of large samples• High optical throughput and exceptional signal-to-noise ratio• Analysis of powders, ground solid samples and coatings on metallic surfaces
• Pre-aligned, fixed-position optical components for reproducible,high quality data
• Micrometer controlled sample stage positioning and focusing• Optional gold-coated optics version for highest performance mid-IR and NIR applications
Analysis of a large painted metal panel using the UpIR accessory
Optical geometry for the UpIR
OR D E R I N G IN F O R M AT I O N
PA R T N U M B E R D E S C R I P T I O N
044-10XX UpIR – Out-of-compartment Diffuse Reflectance AccessoryIncludes solids sampling insert, powders sampling insertwith ZnSe window, gold mirror, purge tubes, purge kit and spectrometer base mount.
044-60XX UpIR – Out-of-compartment Diffuse Reflectance Accessorywith Gold-Coated Optics Includes solids sampling insert, powders sampling insert with ZnSe window, gold mirror,purge tubes, purge kit and spectrometer base mount.
Notes: Replace XX in part number with code for your spectrometer model found onthe last page of this catalog.
UpIR OptionsPA R T N U M B E R D E S C R I P T I O N
044-3030 Solids Sampling Insert
044-3040 Powders Sampling Insert
044-3010 21 mm Glass Vial Holder
044-3020 Sample Vials with Threaded Caps, 21 mm x 70 mm, (200 per package)
160-1155 25 x 2 mm ZnSe Window
160-1307 25 x 2 mm Ge Window
160-1201 25 x 2 mm AMTIR Window
160-5000 25 x 2 mm Sapphire Window
Notes: Solids and Powders Sampling Inserts do not include a window – please makea selection from the list above.
03_Diffuse 12-12-12_03_Diffuse 12/13/12 1:17 PM Page 37
The AutoDiff is a high performance, automated diffuse reflectanceaccessory developed to analyze multiple samples with minimaluser intervention. Typical applications include powdered pharma-ceutical samples, high throughput forensic sampling, kidney stoneanalysis, soils analysis and analysis of many other powderedsamples where speed and efficiency are important. The designemploys an automated R-theta sampling stage with positions forup to 60 samples, providing diffuse reflectance analysis withgreatly reduced operator intervention and increased samplethroughput.
The optical design of the AutoDiff utilizes a high efficiencyfixed ellipsoidal reflector to collect the maximum amount of diffusely reflected energy from the sample. Other optical compo-nents important to achieving this high performance are alignedand permanently located. The accessory is baseplate mounted inthe FTIR spectrometer sample compartment and can be purgedindependently or it can use the spectrometer’s purge.
Spectral quality and reproducibility are excellent with theAutoDiff. By programming the collection of spectra at precisetime periods and alternating sample and background collection,any effects of atmosphere are greatly reduced.
The PIKE AutoDiff fully automates diffuse reflectance FTIRspectroscopy. The sample holder contains positions for sixty samples,plus a center position for a background sample, which usuallyconsists of pure KBr powder.
The sample plate is marked intosix areas, labeled from A to F. Eacharea has ten sample positions markedfrom 1 through 10. This sample position numbering scheme is alsoused within the software for describingand positioning the samples.
The AutoDiff is controlled by PIKEAutoPRO software which incorporatesmulti-operator sample submission. Thesystem is extremely flexible and thegraphical user interface is intuitiveand simple. Multiple operators may independently log samplesonto the system. The AutoPRO software integrates easily withmost commercially available FTIR software packages.
The AutoDiff is also available with gold-coated optics forhighest performance mid-IR analysis and for automated NIR diffuse reflectance sampling.
AutoDiff – Automated Diffuse Reflectance Sampling
Spectra of pharmaceuticals using the AutoDiff accessory
PIK
ET
EC
HN
OL
OG
IES
WW
W.
PIK
ET
EC
H.
CO
M6
08
-27
4-2
72
1
38
FE AT U R E S O F TH E AU TOD I F F
• Complete automated diffuse reflectance accessory and softwarepackage for unattended analysis of up to 60 samples
• High-performance optical design-collecting maximumamount of diffusely reflected energy and providing highquality spectra in a short time period
• Flexible sample sequencing and background collection toprovide maximum sampling efficiency and greatly minimizeatmospheric contributions to sample spectra
• Easily programmable AutoPRO software providing automatedsample collection and storage
• Easily removable sample tray to speed sample loading and unloading
OR D E R I N G IN F O R M AT I O N
PA R T N U M B E R D E S C R I P T I O N
043-28XX AutoDiff – Automated Diffuse Reflectance SystemIncludes: Motion Control Unit (85/265 VAC), AutoPROSoftware, 60 Position Sample Mounting Tray, 60 Macro Sample Cups and Sample Preparation Kit
043-78XX AutoDiff – Automated Diffuse Reflectance System, Gold-Coated Optics System Includes: Motion Control Unit (85/265 VAC), AutoPROSoftware, 60 Position Sample Mounting Tray, 60 MacroSample Cups and Sample Preparation Kit
Notes: Replace XX code in part number with your spectrometer model – see lastpage of this catalog.
Replacement Parts and OptionsPA R T N U M B E R D E S C R I P T I O N
043-3090 AutoDiff Set of 60 Sampling Cups, Large
043-0900 AutoDiff, 60 Position Sampling Tray
042-2010 Small Sample Cup (micro: 6.0 mm diameter, 1.6 mm deep),2 per package
042-2020 Large Sample Cup (macro: 10 mm diameter, 2.3 mm deep),2 per package
042-3010 Abrasion Sampling Kit
042-3020 Silicon Carbide Abrasive Disks (Pack of 100)
042-3025 Diamond Abrasive Disks (Pack of 50)
042-3080 Alignment Mirror
042-3082 Alignment Mirror, Gold
03_Diffuse 12-12-12_03_Diffuse 12/13/12 1:17 PM Page 38
39
DIF
FU
SE
RE
FL
EC
TA
NC
E–
FROM
POWDERS
TO
PLASTICBUMPERS
X, Y Autosampler – Transmission and Reflection, AutomatedSampling in Microplate Format
The PIKE Technologies X, Y Autosampler is designed around standard 24, 48 or 96-well microplate architectures – ideal forhigh efficiency sample loading and FTIR analysis. The loading traymoves to a position outside of the accessory for easy loading andunloading of samples while conserving the purge. This also permitsinterface to a robot/autoloader.
Applications include high throughput analysis of liquid residuesand chemical reactions, powdered samples, and automated diffusereflection analysis. The X, Y Autosampler is available with standardall-reflective optics or with gold-coated optical components forhighest performance in mid-IR and optimized NIR sampling.
The Autosampler features an X, Y stage with both axes drivenby high precision servo motors with optical encoders for speedand reproducibility. USB and DC power are the only external connections required for this accessory. The transmission optionrequires an external IR detector port.
Programming and control of the X, Y Autosampler is donethrough PIKE Technologies’ AutoPRO software, which can be integrated easily with most FTIR software packages.
The optical design of the X,Y Autosampler is based upon aprecision ellipsoidal reflector. The size of the spot illuminated at the sample is approximately 2 mm – ideal for up to 96-wellconfigurations. The accessory is compatible with most brands and models of FTIR spectrometers.
A special silicon well plate is available for sample analysisby transmission. This unique 96-well plate allows collection of transmission spectra in mid-IR range. For diffuse reflectionmeasurements a dedicated plate is available. The plate features96 polished cavities for placement of powder samples. Pleasecontact PIKE Technologies if you require specialized samplingplate configurations.
High quality FTIR spectra ofsolvent residuescollected with the X, Y Autosampler
OR D E R I N G IN F O R M AT I O N
PA R T N U M B E R D E S C R I P T I O N
047-21XX X, Y Autosampler – Diffuse Reflectance ConfigurationIncludes: AutoPRO Software and 96-Well Diffuse Reflectance Sampling Plate
047-61XX X, Y Autosampler – Diffuse Reflectance Configuration with Gold-Coated OpticsIncludes: AutoPRO Software and 96-Well Diffuse ReflectanceSampling Plate
047-22XX X, Y Autosampler – Diffuse Reflectance/Transmission ConfigurationIncludes: AutoPRO Software, integrated DTGS detector, 96-Well Diffuse Reflectance and 96-Well Transmission Sampling Plates
047-62XX X, Y Autosampler – Diffuse Reflectance/TransmissionConfiguration with Gold-Coated OpticsIncludes: AutoPRO Software, integrated DTGS detector, 96-WellDiffuse Reflectance and 96-Well Transmission Sampling Plates
Notes: Replace XX in part number with code for your spectrometer listed on the last page of this catalog. For other options please contact PIKE Technologies. Fortransmission option your spectrometer must be capable of interfacing with anexternal detector.
X,Y Autosampler OptionsPA R T N U M B E R D E S C R I P T I O N
073-9110 96-Well Diffuse Reflectance Sampling Plate
073-9130 96-Well Transmission Sampling Plate
X, Y AUTOSAMPLER SPEC IF ICAT IONS
Optics Elliptical – 3X beam de-magnification
Accuracy +/- 25 µm
Mechanical Specifications
Repeatability +/- 5 µm
Resolution 1 µm
Minimum Run Time 56 seconds for 96-well plate (Actual time isspectrometer and application dependent)
Computer Interface USB
Dimensions (W x D x H) 6.25 x 13.2 x 5.55" (including micrometer)
Weight 10 lbs
F E AT U R E S O F TH E X ,Y AU TO S A M P L E R
• Complete hardware and software package for automatedanalysis with standard 24, 48, or 96-well plates. Special configurations available.
• Diffuse reflectance of powdered samples or specularreflectance sampling for reaction residues
• Gold-coated optics version for highest performance mid-IRand NIR sampling
• Optional transmission sampling with integrated DTGS detectorand transmission sampling plates
• Fully enclosed, purgeable design with CD-style loading tray• In-compartment mounting, compatible with most FTIR spectrometers
03_Diffuse 12-12-12_03_Diffuse 12/13/12 1:18 PM Page 39
Sample Preparation and Loading Kit – The Easiest Way to Work With Powder Samples
Abrasion Sampling Kit – The Plastic Bumper Sampler
The Sample Preparation Kit makes the handling of powder samples for diffuse reflectance sampling easy. It includes a roundmounting base and a matching tray with an opening whichaccommodates sampling cups. The cup is placed in the assemblyand overfilled with sample, and then excess powder is leveled-offwith a spatula. The overflow is retained on the tray and can beeasily returned to the sample container or disposed.
Two standard sampling cups offer 0.18 and 0.03 cubic centimeter capacities (10 mm diameter/2.3 mm depth and 6.0 mmdiameter/1.6 mm depth). The required approximate weight of thesample/KBr mixture is 450 mg for the large cup and 80 mg forthe small one.
Please note, the Sample Preparation and Loading Kit isincluded with PIKE Technologies EasiDiff and DiffusIR diffusereflectance accessories.
PIK
ET
EC
HN
OL
OG
IES
WW
W.
PIK
ET
EC
H.
CO
M6
08
-27
4-2
72
1
40
The Abrasion Sampling Kit consists of an abrasion disk holder and a set of silicone carbide (SiC) and diamond disks. Sampling isperformed by abrading the surface of the investigated substancewith a selected disk. The disk is placed in the accessory and a diffuse reflectance spectrum of the material is collected. Thismethod is particularly useful for the analysis of large painted surfaces (e.g. car panels) and other awkward objects.
• Convenient set of tools for collection of difficult solid samples
• Rigid construction, diamond and silicon carbide disks
OR D E R I N G IN F O R M AT I O N
PA R T N U M B E R D E S C R I P T I O N
042-3040 Sample Preparation KitIncludes: two Micro and Macro cups, Alignment Mirror,Sampling Cup Holder and Base, Two Spatulas, Brush
042-2010 Small Sample Cup (micro: 6.0 mm diameter, 1.6 mm deep),2 per package
042-2020 Large Sample Cup (macro: 10 mm diameter, 2.3 mm deep), 2 per package
042-3030 Delrin® Sampling Cup Holder and Base
042-3080 Alignment Mirror (Aluminum)
042-3082 Alignment Mirror, Gold
042-3070 Camel Hair Brush
042-3035 Spatula (Spoon)
160-8010 KBr Powder (100 g)
042-3050 Spatula (Flat)
OR D E R I N G IN F O R M AT I O N
PA R T N U M B E R D E S C R I P T I O N
042-3010 Abrasion Sampling KitIncludes: Heavy Duty Sampling Tool and Stainless Steel Disk Support, 75 SiC Disks and 25 Diamond Abrasive Disks
042-3020 Silicon Carbide Abrasive Disks (Pack of 100)
042-3025 Diamond Abrasive Disks (Pack of 50)
042-3060 Abrasion Kit Disk Support Post
03_Diffuse 12-12-12_03_Diffuse 12/13/12 1:18 PM Page 40
41
DIF
FU
SE
RE
FL
EC
TA
NC
E–
FROM
POWDERS
TO
PLASTICBUMPERS
Diffuse Reflectance – Theory and ApplicationsDiffuse Reflectance – Ideal for Powdered Samples and Intractable SolidsDiffuse reflectance is an excellent sampling tool for powdered orcrystalline materials in the mid-IR and NIR spectral ranges. It canalso be used for analysis of intractable solid samples. As withtransmission analysis, samples to be run by diffuse reflectance aregenerally ground and mixed with an IR transparent salt such aspotassium bromide (KBr) prior to sampling. Diffuse reflectance isan excellent sampling technique as it eliminates the time-consumingprocess of pressing pellets for transmission measurements. Diffusereflectance can also be used to study the effects of temperatureand catalysis by configuring the accessory with a heating chamber.
Perhaps one of the greatest additional benefits of diffusereflectance sampling is that it is ideally amenable to automation.Methods can be developed with a manual version diffuse reflectionaccessory and then moved to automation to increase samplethroughput. PIKE Technologies offers several diffuse reflectanceaccessory configurations – basic, advanced with heat chambercapabilities, upward directed IR beam for easy sampling access,and fully automated for maximum sampling efficiency.
How Diffuse Reflectance WorksDiffuse reflectance relies upon the focused projection of the spectrometer beam into the sample where it is reflected, scat-tered and transmitted through the sample material (shown onthe right). The back reflected, diffusely scattered light (some of which is absorbed by thesample) is then collected by theaccessory and directed to thedetector optics.
Only the part of the beamthat is scattered within a sampleand returned to the surface is considered to be diffuse reflection.
Some powders may be analyzed by diffuse reflectance asneat samples (coal samples, soil samples, diffuse coatings on areflective base). Usually, the sample must be ground and mixedwith a non-absorbing matrix such as KBr. The sample to matrixratio should be between 1 to 5% (by weight). Diluting ensures adeeper penetration of the incident beam into the sample whichincreases the contribution of the scattered component in thespectrum and minimizes the specular reflection component.
The specular reflectance component in diffuse reflectancespectra causes changes in band shapes, their relative intensity,and, in some cases, it is responsible for complete band inversions(Restrahlen bands). Dilution of the sample with a non-absorbingmatrix minimizes these effects (particle size and sample loadingmechanics also play an important role).
This is shown below in the spectral data for caffeine, wherethe upper spectrum is diluted to about 2% by weight in KBr anddemonstrates very high quality with sharp, well-definedabsorbance bands. The lower spectrum is of undiluted caffeinemeasured by diffuse reflectance and shows derivative shapedbands in the 1700 cm-1 and 1500 cm-1 region of the data. Theupper spectrum of diluted caffeine is clearly of higher spectralquality than that of the undiluted caffeine.
Other factors related to high spectral quality for diffusereflectance sampling are listed below;
• Particle Size – reducing the size of the sample particles reducesthe contribution of reflection from the surface. Smaller particlesimprove the quality of spectra (narrow bandwidths and betterrelative intensity). The recommended size of the sample/matrixparticles is 50 micrometers or less (comparable to the consistencyof the finely ground flour). This fine powder is easily achievedby using a ShakIR mixer.
• Refractive Index – effects result in specular reflectance contri-butions (spectra of highly reflecting samples will be more distorted by the specular reflectance component). This effectcan be significantly reduced by sample dilution.
• Homogeneity – samples prepared for diffuse reflectance measurements should be uniformly and well mixed. Non-homogenous samples will lack reproducibility and will be difficult to quantify. An ideal way to mix samples for diffusereflectance is by using a ShakIR.
• Packing – the required sample depth is governed by the amountof sample scattering. The minimum necessary depth is about1.5 mm. The sample should be loosely but evenly packed in the cup to maximize IR beam penetration and minimize spectral distortions.
Diffuse reflective spectra showing greatly improved results from sample dilution
03_Diffuse 12-12-12_03_Diffuse 12/13/12 1:18 PM Page 41
PIK
ET
EC
HN
OL
OG
IES
WW
W.
PIK
ET
EC
H.
CO
M6
08
-27
4-2
72
1
42
Even with all these sample preparation practices, the raw diffuse reflectance spectra will appear different from its transmissionequivalent (stronger than expected absorption from weak IR bands).A Kubelka-Munk conversion can be applied to a diffuse reflectancespectrum to compensate for these differences. This conversion isavailable in most FTIR software packages.
The Kubelka-Munk equation is expressed as
where R is the absolute reflectance of the sampled layer, k is themolar absorption coefficient and s is the scattering coefficient.
The spectra shown above demonstrate this spectral conversionfor ibuprofen collected by diffuse reflectance. The sample wasdiluted to about 1% by weight in KBr and mixed using the ShakIR.The Kubelka-Munk converted spectrum for ibuprofen showsexcellent comparison with the transmission spectrum and is easilyidentified using library search of a transmission spectral data base.
The Kubelka-Munk equation creates a linear relationship forspectral intensity relative to sample concentration (it assumesinfinite sample dilution in a non-absorbing matrix, a constantscattering coefficient and an “infinitely thick” sample layer). These conditions can be achieved for highly diluted, small particle samples (the scattering coefficient is a function of sample sizeand packing) and a sample layer of at least 1.5 mm. With propersample preparation diffuse, reflectance spectroscopy can provideppm sensitivity and high quality results.
Plastic Bumpers and Tough SamplesSometimes it is necessary to analyze a sample which simply doesnot fit in a spectrometer’s sample compartment – the analysis ofpolymer-based automotive components or painted panels aretypical examples.
A special diffuse reflectance technique allows quick and simpleanalysis of such samples in a relatively non-destructive manner. A small amount of the sample can be collected by abrasion on a diamond or silicon carbide (SiC) abrasion disk and analyzedimmediately with the help of a diffuse reflectance accessory.
The figure above shows the diffuse reflectance spectrum of aautomotive body component. The PIKE Abrasion Kit with diamondsampling disk was rubbed across the large automotive componentwhich collects some of the polymer material into the web of thesampling disk. Spectra were co-added for a 1 minute time periodand ratioed to the diamond disk background spectrum. Theresulting spectrum is of excellent quality and is identified as apolypropylene copolymer.
Diffuse reflectance can also be used for the analysis of liquidsamples. In this application a small amount of the sample is dispensed directly onto the KBr powder and analyzed.
For the analysis of powders the following procedure is recommended;
• Place about 200–400 mg of KBr into the ShakIR vial and shakefor 30 seconds
• Fill the background diffuse cup with this KBr
• Remove excess KBr with a flat edge – the KBr should be loosely packed
• Add 1 to 5 mg of the sample to the remaining KBr in theShakIR vial and shake for 30 seconds
• Fill the sample diffuse cup with this mixed sample/KBr
• Remove excess sample with a flat edge – the sample should be loosely packed
• Place the background and sample diffuse cups into the sample holder
• Slide the sample holder into the accessory
• Position the KBr cup in the beam and collect a background
• Move the holder to the sample position and collect a samplespectrum (the ratio of these two spectra will produce a spectrum of the sample)
• Convert the raw diffuse reflectance spectrum to Kubelka-Munk
Under ideal conditions the transmission of the strongestband in the spectrum should be in the 50% range. If the resultingbands are too intense or distorted, further dilute the sample andmake sure that all other measurement affecting factors (particlesize, homogeneity and packing) are within required limits.
SummaryDiffuse reflectance accessories make the analysis of a wide rangeof solid samples easier, faster and more efficient. Advanced optionsfor diffuse reflectance provide the ability to heat the sample and monitor a reaction process. Automation versions of diffusereflectance accessories provide the ability to greatly increase sample throughput.
Diffuse reflectance spectra of ibuprofen with and without Kubelka-Monk conversion
Diffuse reflectance spectrum using diamond abrasion disk
03_Diffuse 12-12-12_03_Diffuse 12/13/12 1:18 PM Page 42
Specular Reflectance Specular reflectance is an excellent sampling
technique for measurement of thin films on
reflective substrates and for non-invasive analysis
of samples. The specular reflectance spectrum may
be used for sample identification, for quality control
of coated materials, for analysis of monolayers and
for film thickness measurement.
PIKE Technologies offers several versions of
specular reflectance accessories to address
applications from research to quality control.
VeeMAX™Research Grade SpecularReflectance Accessory – with variable angle of incidence
Page 44
30Spec™Fixed angle Specular Reflectance –for relatively thick films
Page 46
80Spec™Analysis of monolayers and other relatively thin films
Page 47
AGA™80 degree Specular Reflectancewith precise control of sampling size
Page 48
10Spec™Fixed 10 degree specular forE1585-93 reflectance method
Page 49
Specular ReflectanceTheory and Applications
Page 51
Absolute Reflectance AccessorySpecular Reflection Accessory – to measure sample reflectivity
Page 50
04_Specular 12-12-12_04_Specular 12/13/12 1:20 PM Page 43
VeeMAX III – The Ultimate Variable Angle Specular Reflectance Accessory
The PIKE Technologies VeeMAX III is a high performance and highlyversatile specular reflectance accessory designed to analyze awide range of samples. From monolayers to relatively thick films,the VeeMAX III with variable angle of incidence can be optimizedfor all specular applications. The unique optical design of thisproduct (U.S. Patent No. 5,106,196) enables the accessory to be inalignment for all angles of incidence. The angle may be variedcontinuously from thirty to eighty degrees by the rotation of asingle control. The sample is placed face down on the samplingsurface. Because of the unrestricted access to the sampling area,large samples may be readily analyzed. To suit different samplinggeometries, masks with 2", 5/8" and 3/8" apertures are provided.Thanks to the optical design of this accessory, excellent throughputis available even at high angles of incidence. The VeeMAX III has abuilt-in polarizer mount to permit selection of polarization anglewithout disturbing purge.
An optional motorized version of the accessory is available. Itfeatures a stepper motor with complementary electronics, MotionControl Unit, and PIKE Technologies AutoPRO software. In thiscombination, operation of the VeeMAX III can be integrated withthe spectrometer software, which allows the operator to preciselyand reliably control a wide range of angles of incidence and datacollection simultaneously from the computer keyboard.
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
44
F E AT U R E S O F T H E V E E M A X I I I
• Selectable angle of incidence – from 30 to 80 degrees in onedegree increments
• Measurement of thin films and monolayers to relativelythick films
• Optimize specular reflectance results with selectable angle of incidence
• Integrated position for IR polarization – essential for monolayer analysis and study of sample orientation
• Optional single reflection ATR crystals – see ATR section• Motorized version option with electronic control module andAutoPRO software for automated, high-precision experiments
• Sealed and purgeable optical design to eliminate watervapor and carbon dioxide interferences
Proprietary beam path within the VeeMAX III Specular Reflectance accessory
Optimization of the analysis of a multi-layered coating on metal substrate using the VeeMAX III
04_Specular 12-12-12_04_Specular 12/13/12 1:20 PM Page 44
Changing the angle of incidence with the VeeMAX III is veryeasy. With this research grade specular reflectance accessory, onecan measure film thickness ranging from relatively thick to relativelythin, including monolayers, by selecting the optimal angle of incidence for the measurement.
The variable angle of incidence can be controlled manuallyor with an optional motorized attachment for the VeeMAX III.Multiple specular measurements at different angles of incidencecan be fully automated with the motorized version and PIKETechnologies AutoPRO software. Automation streamlines the collection of spectra from multiple angles of incidence. With theautomated VeeMAX III accessory, the entire experiment can be pre-programmed and executed by the computer.
Advantages of the automated VeeMAX III system include:
• Computer controlled precision, accuracy and repeatability
• Synchronization of mirror position changes with collection ofsample spectra
• Full integration of the PIKE Technologies AutoPRO software withFTIR spectrometer programs
• Tailor made, predefined experiments
• “Hands-free” operation
45
SP
EC
UL
AR
RE
FL
EC
TA
NC
E–
THIN
FILMS
AND
MORE
AutoPRO Software control of VeeMAX III angle of incidence forautomated specular reflectance studies – automated polarizer available
O R D E R I N G I N F O R M AT I O N
VeeMAX III AccessoryP A R T N U M B E R D E S C R I P T I O N
013-11XX VeeMAX III – Variable Angle Specular Reflectance AccessoryIncludes sample masks (2", 5/8" & 3/8"), gold substratealignment mirror, FTIR base mount, and purge tubes.
Notes: Select FTIR XX code from the last page of this catalog.
VeeMAX III Sampling OptionsP A R T N U M B E R D E S C R I P T I O N
013-2851 Motorized Option for VeeMAX III
013-2801 Motorized Upgrade for VeeMAX III
090-1000 Manual Polarizer, ZnSe
090-1200 Manual Polarizer, KRS-5
090-3000 Precision Manual Polarizer, ZnSe
090-3200 Precision Manual Polarizer, KRS-5
090-4000 Precision Automated Polarizer, ZnSe
090-4200 Precision Automated Polarizer, KRS-5
Notes: Motorized Option includes PIKE Technologies AutoPRO software and controller.Other polarizer options are found in the polarizer section of this catalog.
VeeMAX III Replacement PartsP A R T N U M B E R D E S C R I P T I O N
010-3010 Specular Mask Set
300-0002 Gold Substrate Alignment Mirror (1.25" x 3.0")
Notes: Please contact PIKE Technologies for items not described in this list.
FTIR spectrum of thiol monolayer measured using the VeeMAX III specular reflectance accessory set at 80 degrees angle of incidence, ZnSe polarizer and MCT detector.
VEEMAX I I I S P E C I F I C AT I O N S
Optics All reflective
Angle of Incidence Range 30° to 80°
Sample Masks 2", 5/8" and 3/8"
Purge Sealing Purge tubes and purge barb included
Dimensions (W x D x H) 177 x 92 x 162 mm (excludes baseplate)
FTIR Compatibility Most, specify model and type
04_Specular 12-12-12_04_Specular 12/13/12 1:20 PM Page 45
30Spec and 45Spec – Specular Reflectance for Thick Films
The PIKE Technologies 30Spec is ideal for the measurement of relatively thick films by specular reflectance. Samples are simplylaid across the top of the accessory and the spectrum of the filmis measured within a short time period. The 30Spec includes samplemasks of 3/8", 1/4" and 3/16" to define specific sampling areas.The 30Spec provides high quality FTIR spectra for identification ofcoatings and can also be used to measure coating thickness.
IR throughput is high using the 30Spec due to the relativelysimple optical design of the product.
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
46
F E AT U R E S O F T H E 3 0 S P E C
• Measurement of thick films• Measurement of film thickness by specular reflectance• Fixed 30 degree angle of incidence• Special version – 45Spec for fixed 45 degree angle of incidence• Sample masks to define sampling area• Slide mount design for easy installation of accessory – fits all FTIR spectrometers
Optical geometry for the 30Spec
O R D E R I N G I N F O R M AT I O N
30Spec and 45Spec AccessoryP A R T N U M B E R D E S C R I P T I O N
011-1000 30Spec – Specular Reflectance Accessory (30 degree)Includes sample masks (3/8", 1/4", and 3/16"), alignmentmirror and slide mount.
011-4500 45Spec – Specular Reflectance Accessory (45 degree)Includes sample masks (3/8", 1/4", and 3/16"), alignmentmirror and slide mount.
Notes: The 30Spec and 45Spec are slide mount accessories.
30Spec and 45Spec Sampling OptionsP A R T N U M B E R D E S C R I P T I O N
011-2010 Sample Masks (3/8", 1/4", and 3/16")
300-0039 Alignment Mirror
Notes: Sample masks and alignment mirror fit 30Spec and 45Spec.
FTIR spectrum of polymer coating on a food container run with thePIKE 30Spec
04_Specular 12-12-12_04_Specular 12/13/12 1:20 PM Page 46
80Spec – Grazing Angle Specular Reflectance for Thin Films
The PIKE Technologies 80Spec is ideal for the measurement of relatively thin films and mono-molecular layers by specularreflectance. Samples are simply laid face down across the top ofthe accessory and the spectrum of the film is measured. Generallythe measurement of ultra-thin film samples, especially monolay-ers, is significantly enhanced by using P-polarized light, with theelectric field vector perpendicular to the sample surface. The80Spec includes polarizer mounts on both incoming and outgoingbeams for positioning optional manual or automated IR polarizersfrom PIKE Technologies.
The 80Spec is available in two versions. The basic configurationfeatures a flat sampling surface with fixed sampling port. This version is ideal for analysis of larger, uniform samples. The secondversion includes 3 sample masks to define smaller areas on asample. This version is recommended for smaller samples or formeasurement of variations in thin film coatings.
47
SP
EC
UL
AR
RE
FL
EC
TA
NC
E–
THIN
FILMS
AND
MORE
F E AT U R E S O F T H E 8 0 S P E C
• Measurement of thin films and mono-molecular layers• Fixed 80 degree angle of incidence• Gold-coated reflective optics for highest throughput grazing angle analysis
• Dual polarizer mounts for incoming and outgoing IR beam• Optional sample masks version to define unique sampling areas• Baseplate mount design for stable operation and collectionof high quality spectra – fits all FTIR spectrometers
Beam path within the 80Spec – Specular Reflectance accessory
O R D E R I N G I N F O R M AT I O N
80Spec AccessoryP A R T N U M B E R D E S C R I P T I O N
012-10XX 80Spec – Specular Reflectance AccessoryIncludes a gold substrate alignment mirror, dual polarizer mount and FTIR base mount
012-11XX 80Spec – Specular Reflectance Accessory with Sample Masks (3/8", 5/8" and 2")Includes a gold substrate alignment mirror, dual polarizer mount and FTIR base mount
Notes: Select FTIR XX code from the last page of this catalog.
80Spec Replacement Parts and OptionsP A R T N U M B E R D E S C R I P T I O N
010-3010 Specular Mask Set
300-0002 Gold Substrate Alignment Mirror (1.25" x 3.0")
090-1000 Manual Polarizer, ZnSe
090-1200 Manual Polarizer, KRS-5
Notes: For other polarizer options see PIKE Technologies polarizer section of this catalog.
FTIR spectrum of an ultra-thin film on a reflective substrate using P-polarized IR beam
04_Specular 12-12-12_04_Specular 12/13/12 1:20 PM Page 47
AGA – Advanced Grazing Angle Specular Reflectance for Thin Films with Precise Spot Control
The PIKE Technologies AGA – Advanced Grazing Angle specularreflectance accessory is a novel instrument designed for quantitativemeasurement of spatially defined areas of thin films on reflectivesubstrates. Traditional grazing angle accessories produce a sampling area which is elliptical in shape and non-uniformly illuminates the sample area. This large asymmetrical samplingarea causes problems when quantitative analysis are to be performed on small sample areas.
The Advanced Grazing Angle (AGA) accessory has beendesigned to overcome this deficiency. The size and shape of theilluminated spot on the sample is defined by the optics containedin the accessory. The AGA optical design uses primary imagingfrom one of 5 user defined, slide-mounted pin mirrors selectablefrom 1/8" to 1/2".
The beam from the spectrometer is focused onto the pin mirror. The angle of incidence is equal to 80 degrees. The portionof the beam that is reflected from this mirror is imaged at unitmagnification onto the sample, striking it at the same 80 degrees.Thus, the beam at the sample position is uniform and circular indimension – providing excellent quantitative results for thedefined sample area.
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
48
F E AT U R E S O F T H E A G A
• Quantitative measurement of small areas of thin films andmono-molecular layers
• Fixed 80 degree angle of incidence• Measurement of lubricants on hard disks• Sampling dimensions selectable from 1/8", 3/16", 1/4", 3/8" and 1/2" sizes
• Polarizer mount for optional polarizer• Baseplate mount design for stable operation and collectionof high quality spectra – fits all FTIR spectrometers
• Spectral range 10,000–500 cm-1
Beam path within the AGA – Grazing Angle Specular Reflectance accessory
O R D E R I N G I N F O R M AT I O N
AGA AccessoryP A R T N U M B E R D E S C R I P T I O N
015-10XX AGA – Grazing Angle Specular Reflectance AccessoryIncludes: 5 selectable spot sizes of (1/8", 3/16" 1/4", 3/8" and 1/2"), gold substrate alignment mirror, polarizer mount and FTIR base mount.
Notes: Select FTIR XX code from the last page of this catalog.
AGA Replacement Parts and Sampling OptionsP A R T N U M B E R D E S C R I P T I O N
300-0002 Gold Substrate Alignment Mirror (1.25" x 3.0")
090-1000 Manual Polarizer, ZnSe
090-1200 Manual Polarizer, KRS-5
Notes: For other polarizer options see PIKE Technologies polarizer section of this catalog.
Sampling image on a hard disk surface produced by (A) the spatiallyresolved AGA and (B) a traditional grazing angle accessory
FTIR spectrum of an 18 angstrom thick lubricant on hard disk measuredin 15 seconds using a MCT detector
04_Specular 12-12-12_04_Specular 12/13/12 1:20 PM Page 48
10Spec – Near-normal Sample Reflectivity Measurements
The PIKE Technologies 10Spec is an optimized specular reflectanceaccessory designed to make high performance measurements ofsample reflectivity. The 10Spec produces a collimated beam toilluminate the sample area such that the reflectivity measurementis uniformly 10 degrees and not an average of angles producedby a focused beam accessory design.
The 10Spec specular reflectance accessory is recommendedto measure the reflectivity of glass per ASTM Standard E1585-93.The 10Spec may also be used to measure near-normal reflectivityof a wide variety of surfaces including military devices, reflectingoptics, anti-reflective (AR) coated surfaces, and other reflectingand non-reflecting materials.
49
SP
EC
UL
AR
RE
FL
EC
TA
NC
E–
THIN
FILMS
AND
MORE
F E AT U R E S O F T H E 1 0 S P E C
• Measure sample reflectance• Fixed 10 degree angle of incidence• Measure glass reflectivity per ASTM Standard E1585-93• Sample illumination using collimated beam precisely fixed at 10 degrees
• Sampling mask sizes of 3/8", 5/8" and 2"• Purge covers and purge tubes for removal of atmosphericinterferences
• Baseplate mount design for stable operation and collectionof high quality spectra – fits all FTIR spectrometers
Beam path within the 10Spec – Specular Reflectance accessory
O R D E R I N G I N F O R M AT I O N
10Spec AccessoryP A R T N U M B E R D E S C R I P T I O N
010-10XX 10Spec – 10 Degree Specular Reflectance AccessoryIncludes: 3 sample masks (3/8", 5/8" and 2"), gold substrate alignment mirror and FTIR base mount.
Notes: Select FTIR XX code from the last page of this catalog.
10Spec Replacement Parts and Sampling OptionsP A R T N U M B E R D E S C R I P T I O N
010-3010 Specular Mask Set
300-0002 Gold Substrate Alignment Mirror (1.25" x 3.0")
FTIR spectrum measuring the reflectively of glass with the 10Spec
04_Specular 12-12-12_04_Specular 12/13/12 1:20 PM Page 49
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
50
Absolute Reflectance Accessory – Measure Absolute Sample Reflectance
Sample reflectance is usually measured in comparison to a highreflectance diffuse gold or a high reflectance gold mirror. Thesample reflectance is measured and calculated against these standards that have 94–99% reflectance in the infrared region.
Absolute reflectance measurement has to be even more accurate than measured by other accessories. Unfortunately, nostandards exist today that have guaranteed 100% reflectance,against which unknown samples could be compared. PIKETechnologies have developed a Absolute Reflectance accessorywhich does not require reflectance standards due to its unique V / W optical arrangement. The beam in the V position reflectsfrom the reference mirror. In the W position it is reflecting fromthe sample twice and the same reference mirror at 12°. Theabsolute reflectance of a sample is then the square root of themeasured value at a given wavenumber or wavelength. The twoconfigurations are easily selected by rotating the sample holder180 degrees with its pinned-in-place mount and the sample isheld by a quick-release mount.
F E AT U R E S O F T H E A B S O L U T E
R E F L E C TA N C E A C C E S S O R Y
• For the measurement of absolute reflectance of optical surfaces,windows and metallic surfaces
• Performance evaluation of optical elements• Evaluation of test plates in medical, industrial and military applications
• Fixed 12 degree angle of incidence
Spectrum of a Silicon Plate Measured in the PIKE Absolute ReflectanceAccessory
Beam Path for V and W Positions for PIKE Absolute ReflectanceAccessory 12° Angle of Incidence
O R D E R I N G I N F O R M AT I O N
Absolute Reflectance AccessoryP A R T N U M B E R D E S C R I P T I O N
014-10XX Absolute Reflectance AccessoryIncludes: V / W sample holder, gold substrate alignmentmirror and FTIR base mount
Notes: Select FTIR XX code from the last page of this catalog.
Absolute Reflectance Parts and Sampling OptionsP A R T N U M B E R D E S C R I P T I O N
300-0002 Gold Substrate Alignment Mirror (1.25" x 3.0")
162-5460 Specular Reflectance Standard
04_Specular 12-12-12_04_Specular 12/13/12 1:20 PM Page 50
Specular Reflectance – Theory and ApplicationsSpecular reflectance sampling in FTIR represents a very importanttechnique useful for measurement of thin films on reflective substrates, analysis of bulk materials and measurement of mono-molecular layers on a substrate material. Often the specularreflectance technique provides a means of sample analysis withno sample preparation – keeping the sample intact for othermeasurements.
The basics of the sampling technique involve measurementof the reflected energy from a sample surface at a given angle ofincidence. The electromagnetic and physical phenomena whichoccur at and near the surface are dependent upon the angle ofincidence of the illuminating beam, refractive index and thicknessof the sample and other sample and experimental conditions. Adiscussion of all of the physical parameters and considerationssurrounding the specular reflectance sampling technique isbeyond the scope of this overview. We will present the specularreflectance sampling technique from an applications orientedperspective.
Types of specular reflectance experiments
• Reflection-Absorption of relatively thin films on reflective substrates measured at near normal angle of incidence
• Specular Reflectance measurements of relatively thick samplesmeasured at near normal angle of incidence
• Grazing Angle Reflection-Absorption of ultra-thin films or mono-layers deposited on surfaces measured at high angle of incidence
In the case of a relatively thin film on a reflective substrate,the specular reflectance experiment may be thought of as similarto a “double-pass transmission” measurement and can be represented as shown in the following illustration;
The incident FTIR beam represented by I0 illuminates the thinfilm of a given refractive index, n2 and at an angle of incidence, θ1.Some of the incident beam is reflected from the sample surface,represented by IR at the incident angle, θ1 and is also known asthe specular component. Some of the incident beam is transmittedinto the sample represented by IT at an angle of θ2 – calculatedfrom Snell’s Law.
n1sinθ1 = n2sinθ2
At the reflective substrate, the beam reflects back to the surface of the thin film. When the beam exits the thin film it hasgeometrically passed through the film twice and is now representedas IA. Infrared energy is absorbed at characteristic wavelengths asthis beam passes through the thin film and its spectrum is recorded.The specular reflectance spectra produced from relatively thinfilms on reflective substrates measured at near-normal angle ofincidence are typically of high quality and very similar to spectraobtained from a transmission measurement. This result is expectedas the intensity of IA is high relative to the specular component, IR.
For relatively thick samples, the specular reflectance experimentproduces results which require additional considerations as thespecular component of the total reflected radiation is relatively high.
Again, the incident FTIR beam represented by I0 illuminatesthe sample of a given refractive index, n2 and at an angle of incidence, θ1. Some of the incident beam is reflected from thesample surface, represented by IR at the incident angle, θ1. Someof the incident beam is transmitted into the sample representedby IT at an angle of θ2. As predicted by Fresnel equations, the percent of reflected vs. transmitted light increases with higherangles of incidence of the illuminating beam. Furthermore, therefractive index of the sample, surface roughness and sampleabsorption coefficient at a given wavelength all contribute to theintensity of the reflected beam.
51
SP
EC
UL
AR
RE
FL
EC
TA
NC
E–
THIN
FILMS
AND
MORE
Spectrum of thin film coating on a metal surface measured at 30 degreesangle of incidence using the VeeMAX III specular reflectance accessory
Beam path for a relatively thick sample measured by Specular Reflection
Beam path for Reflection-Absorption of a relatively thin film measuredby Specular Reflectance
04_Specular 12-12-12_04_Specular 12/13/12 1:20 PM Page 51
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74 2
721
52
At wavelengths where the sample exhibits a strong IR absorption,the reflectivity of the sample increases. The superposition of theextinction coefficient spectrum with the refractive index dispersionresults in a spectrum with derivative shaped bands. This specularreflection spectrum can be transformed using a Kramers-Kronigconversion to a transmission-like spectrum as shown in the example below.
Our third application of specular reflectance is the measure-ment of relatively thin films and mono-molecular layers at grazingangle of incidence. At high angles of incidence, between 60 and85 degrees, the electromagnetic field in the plane of the incidentand reflected radiation is greatly increased relative to a near normalangle of incidence. The perpendicular component of the electro-magnetic field of the reflecting radiation is not enhanced.
Because of the orientation of the electro-magnetic field atthe surface for grazing angle measurements, the use of an IRpolarizer greatly improves the sampling result. By collecting thespectrum at grazing angle of incidence with P-polarization, weonly examine the enhanced portion of the electromagnetic fieldat the sample surface, thereby producing a stronger absorbancespectrum.
Specular reflectance is a valuable FTIR sampling techniquefor the analysis of thin films on reflective substrates, for theanalysis of relatively thick films on reflective materials and foranalysis of bulk materials where no sample preparation is preferred. PIKE Technologies offers a complete line of specularreflectance accessories and options to do these analysis and perform these experiments.
Spectrum (upper – original) of a relatively thick polymer sample measuredat 30 degrees angle of incidence using the VeeMAX III. The lower spectrumhas been transformed using the Kramers-Kronig software algorithm andis very similar to a transmission spectrum of the polymer – polyethylene.
Grazing angle specular reflection analysis produces a strong electro-magnetic field oriented in the plane of the incident and reflected radiation
Grazing angle specular reflection analysis of a thiol mono-molecular layerdeposited on a gold surfaced mirror using the PIKE VeeMAX III at 80 degreesand P-polarization. The FTIR was equipped with an MCT detector.
04_Specular 12-12-12_04_Specular 12/13/12 1:20 PM Page 52
PolarizationPolarizers may be used to detect oriented samples
and for measurement of thin films on reflective
substrates. PIKE Technologies offers several crystal
forms of polarizers and automated versions for
transmission, reflection and ATR sampling.
Manual Polarizers6 different offerings for mid-IR,NIR, and far-IR spectroscopy
Page 54
Automated Polarizers6 different automated versions formid-IR, NIR, and far-IR spectroscopy
Page 54
Infrared PolarizersTheory and Applications
Page 55
05_Polarization 12-12-12_05_Polarization 12/13/12 1:27 PM Page 53
PIKE Technologies offers polarizers for a wide variety of spectroscopyapplications which are available in manual or automated versions.The polarizers are mounted in a standard 2" x 3" slide mount andare compatible with all FTIR spectrometers. Polarizer elements are25 mm in diameter and, with mount, have a 20 mm clear aperture.
The polarizers are also compatible with many PIKE Technologiesaccessories including the 80Spec, VeeMAX, and AGA specularreflectance accessories. If you would like to add mounting to anyof our accessories, please contact us.
PIKE Technologies automatedpolarizers provide specificationsidentical to our manual versions,plus they are fully computer con-trolled, making many previouslylabor-intensive applications feasible.With the automated polarizer ananalysis program can be set upthrough AutoPRO software to automatically collect all spectra.
There are two manual polarizer types available. The short formwith the 5 degree scale resolution and the long form with themore precise, 1 degree scale. The short and long versions of theautomated polarizer are also available to address various samplecompartment and accessory configurations. The automated polar-izers offer the added benefit of increased setting reproducibilitywith accuracy of +/- 0.5 degree.
Polarizers – Manual and Automated Versions for Molecular Spectroscopy
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
54
O R D E R I N G I N F O R M AT I O N
Manual Polarizers (select based upon spectral range and performance requirements)PA R T NUMB E R D E S C R I P T I O N
090-1000 Manual Polarizer, ZnSe
090-1200 Manual Polarizer, KRS-5
090-1500 Manual Polarizer, Ge
090-1400 Manual Polarizer, BaF2
090-1600 Manual Polarizer, Polyethylene
090-1300 Manual Polarizer, CaF2
090-3000 Precision Manual Polarizer, ZnSe
090-3200 Precision Manual Polarizer, KRS-5
090-3500 Precision Manual Polarizer, Ge
090-3400 Precision Manual Polarizer, BaF2
090-3600 Precision Manual Polarizer, Polyethylene
090-3300 Precision Manual Polarizer, CaF2Notes: All manual polarizers are mounted into a 2" x 3" plate for mounting intothe FTIR spectrometer slide sample holder or the appropriate sampling accessory.
Automated Polarizers (select based upon spectral range and performance requirements)PA R T NUMB E R D E S C R I P T I O N
090-2000 Automated Polarizer, ZnSe
090-2200 Automated Polarizer, KRS-5
090-2500 Automated Polarizer, Ge
090-2400 Automated Polarizer, BaF2
090-2600 Automated Polarizer, Polyethylene
090-2300 Automated Polarizer, CaF2
090-4000 Precision Automated Polarizer, ZnSe
090-4200 Precision Automated Polarizer, KRS-5
090-4500 Precision Automated Polarizer, Ge
090-4400 Precision Automated Polarizer, BaF2
090-4600 Precision Automated Polarizer, Polyethylene
090-4300 Precision Automated Polarizer, CaF2Notes: All automated polarizers are mounted into a 2" x 3" plate for mounting intothe FTIR spectrometer slide sample holder or the appropriate sampling accessory.The automated polarizers include the PIKE Technologies Motion Control Unit andAutoPRO software for fully automated operation.
F E AT U R E S O F P O L A R I Z E R S
• Convenient, slide-mount design for all FTIR spectrometers
• Also compatible with many PIKE Technologies accessories
• Available in manual and automated versions
• Available for mid-IR, NIR and far-IR applications
Manual Polarizers
Automated Polarizers
05_Polarization 12-12-12_05_Polarization 12/13/12 1:27 PM Page 54
Polarizers are valuable tools used for spectroscopic analysis ofsample orientation and for measuring thin films on reflective surfaces. This overview presents basic polarization theory andhighlights some useful polarization applications.
For the purposes of discussing polarizers, light is consideredan electric field with a magnitude oscillating in time. Light propagating along the z axis can be described as a combinationof electric vectors in x and y axis. Linearly polarized light may bethought of as consisting of an x and a y component with differentrelative magnitudes. For example, if the y component is close tozero, the light is considered fully polarized in the x direction.
Polarizers are devices that split unpolarized light into twoorthogonal components; one of the linearly polarized componentsis transmitted, the other is reflected, redirected or absorbed. Themost important features of a good polarizer are brightness, contrast and durability. Brightness and contrast can be describedby two main parameters; K1 and K2.
K1 = Transmission efficiency for normally incident polarizedlight whose electric field vector is perpendicular to thewire direction.
K2 = Transmission efficiency for normally incident polarizedlight whose electric field vector is parallel to the wiredirection.
For a ‘perfect polarizer’ K1 = 1, which means full transmissionof polarized light whose electric field vector is in the preferreddirection and K2 = 0, which means complete blockage of a beamof polarized light whose electric vector is perpendicular to the former. Other measures of performance deduced from K1 and K2 are
Degree of polarization =
Extinction Ratio =
Principal transmittance ratio or contrast =
Polarizers may be made from very fine conducting parallelelements or grid placed upon a suitable transparent base material.When the grid spacing is much smaller than the wavelength oflight, the light with the electric vector parallel with the grid willbe reflected and only the component with perpendicular electricvector will be transmitted (shown graphically on the right).
The overall transmission characteristic of the polarizerdepends upon the substrate, but the polarization efficiencydepends upon the period, line width and other design parametersof the polarizer.
In the mid-infrared range, the most practical and commonlyused polarizers are ruled or holographic wire grid structures. Thepolarization effect comes from the same principle as the freestanding wire grid, except the fine wires are formed on the surface of an infrared transmitting optical window material.
Polarization efficiency depends on smaller grid spacing than thewavelength and on the conductivity of the wires. In the case of aruled polarizer, the surface of the optical element is created by a diamond needle to form very fine parallel lines, such as 1200lines/mm, on the surface. The optical element is then placed into avacuum chamber and this pattern is partially coated with aluminumor other evaporated metallic layer. The spacing between theevaporated thin lines has to be very small, typically a fraction ofthe wavelength. Ruled polarizers have good performance and aredurable at high laser powers, but can only be made on hard,non-granular materials that can be ruled, such as ZnSe.
Holography is another method used to form the fine metallicwire pattern on the surface of the polarizer element. Two coherentlaser beams are directed onto the surface of the optical elementwhich is coated with a very thin layer of photo resist. The interference pattern formed at the intersection of the two beamsis allowed to expose the photo resist. The lines in between theexposed photo resist are removed and then coated in a vacuumchamber similar to the ruled grating type. The advantage of holographic polarizers is that a wider variety of materials can beused such as the softer KRS-5. As mentioned earlier, the efficiencyof the polarizer depends on the grid spacing formed among thewires. Holographic techniques allow more uniform grid patternsbecause the spacing is produced optically. Light scatter due toimperfections of ruled grooves are also reduced. If the grid spacingis smaller, the polarizer is more efficient. The spacing errors havealso much less effect on the efficiency if the grid is much smallerthan the wavelength. The trade-off with tighter grid is the reductionof the optical throughput. These parameters are carefully optimizedin the design of the polarizer elements and the right polarizercan be selected for specific experimental conditions.
Specifications and performance characteristics of polarizersoffered by PIKE Technologies are shown in Table 1.
Infrared Polarizers – Theory and Applications
55
PO
LA
RI
ZA
TI
ON
– F
OR
ORIENTED
SAM
PLES
AND
RESEARCH
APPLICATIONS
Cutoff, cm-1 Transmission Undesired Degree of Polarization,Polarizer Type Application Spectral Range Efficiency, K1 Transmission, K2 (K1-K2)/(K1+K2)
ZnSe Mid-IR, General Purpose 460 70% 1% 97%
KRS-5 Mid-IR, Wide-range 200 75% 0.25% 99%
Ge Mid-IR, Highest Efficiency 5500–570 90% 0.25% 99%
Polyethylene Far-IR, Widest Range 500–10 80% 4% 93%
CaF2 NIR Applications 800 85% 1% 98%
BaF2 Mid-IR 840 70% 0.1% 99%
Notes: Efficiency values reported at 1000 cm-1 for mid-IR, at 3300 cm-1 for NIR and 100 cm-1 for far-IR. All polarizers are holographic, wire grid for maximum performance.
Table 1: Polarizer properties
Graphical representation of the polarization effect
05_Polarization 12-12-12_05_Polarization 12/13/12 1:27 PM Page 55
The optical material substrate used to create the polarizersdetermines the wavelength range of the polarizer – such as ZnSeor KRS-5. Table 1 shows the K1 values of PIKE Technologies polarizers.The maximum transmitted light is affected by the transmission ofthe materials and the scattering of the ruled and evaporated surfaces. Fresnel losses are determined by the refractive indexand the performance of the anti-reflection coating on the element.The maximum transmission compared to a fully depolarized openbeam is typically less than 50%. However, FTIR spectrometers produce slightly polarized beams, which in most cases are orientedin the vertical direction in the sample compartment. Thus theapparent transmission of a single polarizer oriented vertically and compared to open beam can be over 50%.
The other critical parameter of polarizers, the contrast, canbe measured by crossing two polarizers and recording thethroughput signal. For efficient polarizers in a practical spectroscopysetting, such as using a converging infrared beam in the samplecompartment of an FTIR spectrometer, it is expected that thelight level should be less than 1%. For selected high performancepolarizers it can be better than 0.5%.
Polarizers are usually mounted in a plastic disc and placed in a rotating holder with an angle scale. This way, the angle ofthe polarizer orientation can be positioned with approximately 1 degree repeatability. Motorized polarizers are available withmuch better angular accuracy and precision. The automatedpolarizers are also very useful for conducting a series of experimentswith different angle settings under complete computer control.
One of the main uses of infrared polarizers is to monitormolecular orientation in samples such as films and fibers. Duringmanufacture polymers tend to orient along the axis of themechanical stretching and this preferred orientation is retainedafter the material stops flowing. In some cases, polymers are amixture of crystalline, more polarized, and amorphous, lesspolarized, forms of the material. In order to study orientation,polarized light is directed on the film or fiber. The polarized lightelectrical vector coinciding with the dipole of the infrared activemoiety increases in absorption intensity, thereby revealing theband assignment and the orientation of the molecular group.Single crystals placed in the focus of polarized light also absorbselectively, depending on the orientation of the crystal.
Polarizers can also be used in conjunction with attenuatedtotal reflection (ATR). Even without polarizers, for any ATR thatretains the orientation relative to the incoming infrared beam,there could be spectral differences noted when an oriented sampleis placed with its direction along the optical axis or perpendicularto it. The phenomenon is related to penetration depth differencesfor the light components polarized parallel or perpendicular withthe reflective surface (see ATR Theory and Applications).
Another important application of polarizers is the enhancementof the signal measuring thin films on polished semiconductors,metallic mirrors and other reflective surfaces.
Using large angle reflectance optics, the grazing anglereflectance of the thin films can be measured. Substantial signalenhancement can be achieved by using polarized light in conjunction with a grazing angle accessory. As an example, a thin oily deposit on a gold mirror can be measured with good signal-to-noise ratio by using polarized light with a specularreflectance accessory set at 80 degrees. Background spectra foreach result were collected at the identical polarization angle asthe sample. As seen in the spectra below, the light polarized suchthat the electric vector is perpendicular to the metallic mirror surface is enhanced. The spectrum measured with the polarizationperpendicular to the surface (electric vector parallel with the surface) is not detected. The non-polarized light measurement isa combination of the two polarized measurements, showing a signal with less contrast than the red trace.
SummaryPolarizers are highly useful spectroscopy sampling tools for the measurement of samples with molecular orientation, for measuring thin films on reflective surfaces and for molecularspectroscopic research.
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
56
Spectra for high density polyethylene (HDPE) with parallel and perpendicular polarization demonstrate that this sample is oriented
FTIR spectra with vertical and horizontal polarization
05_Polarization 12-12-12_05_Polarization 12/13/12 1:27 PM Page 56
Integrating Spheres Integrating spheres are useful for qualitative and
quantitative measurement of sample composition
when morphology, particle size, surface roughness
or sample flatness varies from sample to sample.
PIKE Technologies offers fully integrated accessories
for mid-IR and NIR applications.
Mid-IR IntegratIR™For advanced measurements in the mid-IR spectral region
Page 58
NIR IntegratIR For qualitative and quantitativeanalysis in the NIR spectral region
Page 60
Integrating SpheresIntroduction and Theory
Page 62
06_Integrating 12-13-12_06_Integrating 12/13/12 1:28 PM Page 57
Mid-IR IntegratIR™ – Integrating Sphere
The integrating sphere is very often an accessory of choice whenstudying reflectance properties of solids, analyzing light scatteringand/or highly absorbing samples and collecting spectra difficult toobtain with standard sampling techniques. PIKE Technologiesoffers Mid-IR integrating spheres, designed for research and standard applications that require high sensitivity and ability tocollect high quality data from difficult to analyze samples.
The PIKE IntegratIR spheres are available in the upward anddownward looking configurations and are suitable for the meas-urements of absolute and relative diffuse reflectance of solids,powders and opaque liquids. Both feature 3 inch diameter highlyreflective gold-coated integrating spheres. The accessories mountin the sample compartment of the FTIR spectrophotometer, butuse a dedicated detector for maximum performance.
The upward looking Mid-IR sphere features a 12 degree illumination of the sample, and offers a specular exclusion port.Reflectance samples are placed directly onto the sample portlocated on the top portion of the sphere. This sphere is ideal forlarge and/or thick solid samples. For powder samples, a standardZnSe window is available. If preferred, a KBr window can also beused with the sample plate to minimize the reflection loss com-pared to the ZnSe.
The downward looking Mid-IR IntegratIR allows the sample tobe placed underneath the sphere. This configuration is desirablefor measurements of powders and particulate materials becausean incidence beam strikes the sample directly, without passingthrough an IR transparent window. A specular exclusion port is astandard feature on this accessory.
For all spheres, the selection of light illumination onto thesample or onto the reference surface is done via a flipper mirror.This allows the background to be collected using either the substitution method or the Taylor method.
Diffuse transmittance of partially transmitting materials can bemeasured with either sphere. This is done by placing the sampleon a standard 2" x 3" sample holder and siding it in the mountlocated in front of the transmission port.
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-274-2721
58
FEATUR E S O F THE M ID - I R I N T E GRAT IR
• 3 inch sphere – gold-coated, Lambertian scatterer for high-performance measurements
• 12 degree hemispherical diffuse reflectance measurementwith specular exclusion port
• Diffuse transmission station for measurement of highly scattering samples in transmission mode
• Integrated, high-performance detector MCT or DTGS choicefor ultimate configurability
• Upward and downward-looking optical configurations toaccommodate a wide range of sample sizes and types
• In-sample compartment design to minimize laboratory space requirements
• Configurations available for most FTIR spectrometers
Optical diagram of the upward looking IntegratIR Sphere
Gold-coated Lambertian finish sphere
06_Integrating 12-13-12_06_Integrating 12/13/12 1:28 PM Page 58
A selection of Mercury cadmium telluride (MCT) or deuteratedtriglycine sulfate (DTGS) detectors is offered with the IntegratIRspheres. This allows the accessory to be optimized for the applicationand sample type. The wide band MCT is the commonly configureddetector while the less sensitive DTGS is an option for users whorequire the convenience of a room temperature detector. Theaccessory comes with built-in detector electronics and can beinterfaced to most FTIR spectrometers.
59
INTEGRATINGSPHERES– R
EFLECTANCE
FROM
ALL
PERSPECTIVES
Absolute reflectance spectrum of painted black panel measured usingthe PIKE Mid-IR IntegratIR
Comparison of transmission spectrum of paper collected using the integrating sphere to a spectrum collected in transmission mode withouta sphere
ORDER I NG IN FORMAT I ON
IntegratIR SpheresPA R T NUMB E R D E S C R I P T I O N
048-12XX 12 Degree Upward Sample Positioning Mid-Infrared IntegratIR Integrating Sphere Accessory
048-11XX 12 Degree Downward Sample Positioning Mid-Infrared IntegratIR Integrating Sphere Accessory
Notes: The IntegratIR spheres include the sphere, purge enclosure and tubing, one diffuse gold reference. The Downward IntegratIR includes a powder sample cup.Your FTIR spectrometer must be capable of interfacing with an external detector.
IntegratIR Detector Choice (must select one)PA R T NUMB E R D E S C R I P T I O N
048-3350 Wide-band MCT Detector
048-3250 Mid-band MCT Detector
048-3150 Narrow-band MCT Detector
048-3450 DTGS Detector with CsI Detector Window
Notes: The detector includes the preamplifier electronics. MCT detectors require liquid nitrogen for cooling.
Replacement Parts and Sampling OptionsPA R T NUMB E R D E S C R I P T I O N
048-0108 Sample Plate with 18 x 2 mm ZnSe Window, Upward IntegratIR
048-0208 Sample Plate with 18 x 2 mm KBr Window, Upward IntegratIR
048-3000 Diffuse Gold Reference, Upward Sample Position
048-3001 Diffuse Gold Reference, Downward Sample Position
048-2020 Powder Sample Cup for Downward IntegratIR
INTEGRATIR ACCESSORY SPEC IF ICAT IONS
Optical Design Upward or downward looking sample spheres
Sphere Size and Surface 3" (76.2 mm) gold-coated Lambertian surface
Sample Port Size 23.5 mm
Specular Exclusion Port, Standard12 Degree Sphere
12 Degree Sphere 159 x 248 x 154 mm (excludes baseplate)Dimensions (W x D x H)
Detector Choice DTGS or MCT
Spectral Range, Wide-band: 5000–500 cm-1
MCT Detectors Mid-band: 5000–650 cm-1
Narrow-band: 5000–800 cm-1
Spectral Range, 5000–250 cm-1
Extended DTGS Detectors with CsI Window
06_Integrating 12-13-12_06_Integrating 12/13/12 1:28 PM Page 59
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-274-2721
60
NIR IntegratIR – Integrating Sphere
The PIKE Technologies NIR IntegratIR is a near-infrared (NIR)Integrating Sphere for quantitative and qualitative measurementsof a wide variety of solids and paste materials. The NIR IntegratIR collects reflected energy from a spherical perspective and therebycaptures complete and quantitative response from the sample.Using near-infrared chemometrics, qualitative product identificationand quantitative analysis may be performed on pharmaceutical,nutraceutical, chemical, polymer, textile, food, agricultural andother samples.
The NIR IntegratIR accessory features a 2" high reflectivitygold-coated integrating sphere and a high-speed, low-noise indium-gallium-arsenide (InGaAs) detector, transfer optics andinterface electronics. The NIR IntegratIR fits into the sample compartment of most commercial FTIR spectrometers and itselectronics interface as an external detector of the spectrometer.A 10 mm diameter horizontal sampling port makes the placementof samples onto the accessory very easy. An optimized borosilicatewindow serves as a sampling port at the top of the integratingsphere. The window is bonded and sealed to protect the spherefrom corrosive materials and contamination.
Sampling of tablets, packaging materials and plastics is easilyaccomplished by placing the sample directly on the window ofthe upward facing sphere. Powders, creams, pastes or liquids containing reflective particles may be placed in disposable flat-bottom vials – eliminating the need for any sample cleanup. Thevials may be held in place by a sample-positioning vial holder,resulting in more repeatable measurements.
High quality spectra are produced quickly using the NIRIntegratIR – making qualitative and quantitative analysis of awide variety of sample types efficient and reliable.
For heterogeneous samples, PIKE Technologies offers a RotatingStage for the NIR IntegratIR. With this option, one obtains anaveraged result to eliminate variations in quantitative results forthe chosen sample area.
F E ATUR E S O F THE N IR I N T E GRAT IR
• Optimized 2" gold-coated integrating sphere with high signal-to-noise ratio
• Fully integrated InGaAs detector, detector electronics and transfer optics
• Optional automated transmission analysis stage for pharmaceutical analysis
• 10 mm horizontal sampling port for easy sample placement
• Excellent qualitative and quantitative NIR analysis tool
• Economical alternative to dedicated near-infrared analyzers
• Optional Rotating Stage for averaging of heterogeneous samples
• Spectral range 12200–3850 cm-1
• In-Sample Compartment design, compatible with most commercial FTIR spectrometers Qualitative analysis of steroids using the PIKE Technologies NIR
IntegratIR. Samples are measured within glass vials.
Optical diagram of the NIR IntegratIR Sphere
06_Integrating 12-13-12_06_Integrating 12/13/12 1:28 PM Page 60
61
INTEGRATINGSPHERES– R
EFLECTANCE
FROM
ALL
PERSPECTIVES
The NIR IntegratIR comes complete with diffuse gold reference,sample holders and a removable general-purpose sample mountingplate. The NIR IntegratIR is configured for each specific FTIR spectrometer and includes a pre-aligned mount for your instrument.
The NIR IntegratIR is a cost-effective, high-performance sampling option for laboratories with a standard FTIR spectrometerequipped with a near-infrared light source and beam splitter.
The optional transmission tablet analysis stage for the NIRIntegratIR provides an automated tool for sampling 10 tablets ofa variety of sizes. With this option you can measure formulationreproducibility or verify pharmaceutical composition.
ORDER I NG IN FORMAT I ON
PA R T NUMB E R D E S C R I P T I O N
048-60XX NIR IntegratIR Integrating Sphere AccessoryIncludes 2" diffuse gold-coated integrating sphere, InGaAsdetector, detector preamplifier, cable and baseplate for the specific model spectrometer. The accessory also includes a gold reference standard, vial holder, and 25 glass vials.
Notes: Please see the FTIR instrument code sheet. Your spectrometer must be capable of interfacing with an external detector.
Sampling Options for NIR IntegratIRPA R T NUMB E R D E S C R I P T I O N
048-2999 Glass Sample Vials (Pack of 25), 19 x 65 mm
048-3000 Diffuse Gold Reference
048-3070 NIST Traceable NIR Reference Standard
048-3071 NIST Traceable NIR Reference Standard – Recertification
044-3010 Glass Vial Holder (for 19 mm vials)
048-0150 Rotating Stage for Petri Dish (for heterogeneous samples)Includes 100 x 20 mm Petri Dish
048-0151 Rotating Stage Adapter for 500 mL beaker
048-0060 Automated Transmission Tablet Analysis Stage for NIR IntegratIR Includes 3 tablet plates for 7.5, 8.5 and 10 mm tablets
Note: Please contact us for other options. Stage rotates counterclockwise.
Quantitative measurement of active ingredient in a mixture of magnesiumstearate, lactose, EMCOMPRESS®, cellulose and CAB-O-SIL ®
NIR IntegratIR with optional transmission tablet analyzer
06_Integrating 12-13-12_06_Integrating 12/13/12 1:28 PM Page 61
Integrating Spheres – Introduction and TheoryMeasuring Sample ReflectanceReflectance sampling accessories rely upon a light beam comingfrom the spectrometer to be focused upon the sample. In orderto achieve the best signal-to-noise ratio (SNR), the smaller thefocus is, the easier it is to refocus the illuminated sample spotback onto the detector. In order to measure light reflected at alarger angle, optical designs will allow only a small area of thesample to be projected onto the detector. This arrangementserves well if the sample is microscopically homogeneous, butwill result in a larger sample position error. When the sample ismoved, the focused beam will see a different portion of the sampleresulting in measurement-to-measurement differences. This iscalled insertion error because the spectrum will be slightly different each time the sample is inserted.
Some industrial or natural samples are inhomogeneouseither because they are mixtures of different substances orbecause they have a particle size comparable to the probingbeam diameter. Clearly, if the probing beam could be larger andthe reflected light could all be collected, a more representativespectrum could be measured.
Some other samples develop a directional scattering. Forexample, fibers wound on a mandrel are highly oriented, not justmacroscopically as parallel, unidirectional filaments, but also inmany cases the molecules of the drawn fibers are oriented withinthe fiber itself. Such a sample, when placed in a reflectance accessory will generate different results depending on the anglefrom which the detector is “viewing” the sample. When the overallreflectance needs to be measured reproducibly, for example tomeasure the concentration of a minor ingredient in the sample,only isotropic optical systems, insensitive to such directionalitiescould be utilized.
Furthermore, in some cases, not just the reflectance in asmall solid angle but the reflectance in all angles is sought. Mostreflectance accessories measure at fixed or variable angles, nar-rower or wider collection angles, but there is a need for a devicethat uniformly collects all reflected light from a sample. In otherwords it measures the total reflectance of the sample.
Therefore the main reasons for using integrating spheres forthe measurement of sample reflectance are the following:
• Efficient measurement of combined diffuse and specularreflectance
• Uniform detection of reflectance even when sample is inhomogeneous
• Isotropic detection of reflectance even on samples that reflect in preferred directions
• Reduction of polarization effects from the illuminating beamand the sample
• Measurement of absolute reflectance (with special integrating spheres)
All of the above concerns are addressed with integratingsphere based reflectometers.
Integrating Sphere OpticsIntegrating spheres are highly reflective enclosures that areplaced in close proximity to the sample, such that the reflectedlight enters the sphere, bounces around the highly reflective diffuse surface of the sphere wall and finally impinges upon thedetector – usually part of the integrating sphere assembly. Thename, integrating sphere, refers to one of the main functions ofthe device, namely that it spatially integrates the light flux, in ourapplication the light reflected from a sample. In spite of the longhistory of engineering and development of the sphere, the appli-cations and further developments continue to this day. Advancesin the theory, detector and electronics development and most ofall, new applications, drive the progress.
As the name implies, the main part of the device is a spherewith a very highly reflecting inner surface. The surface shouldapproach the ideal Lambertian scatterer, which means that thelight falling on the surface is evenly scattered in all directions andthe scattered light intensity is proportional to the cosine of theangle of observation.
In an upward sample positioning sphere the infrared beamfrom the interferometer is directed through an entrance portonto the sample placed behind the sample port (shown above).Samples can be directly touching the sphere or separated fromthe sphere by a thin, infrared transparent window. The detector is placed close to the sphere, so that it can view the integratingsphere with a large solid angle. In order to improve the isotropy(non-directionality) of the detection, the detector is not directly inthe line of sight of the sample. A small, also highly reflective andscattering baffle is placed in the sphere such that it blocks thefirst reflection of the sample from reaching the detector.
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-274-2721
62
Optical geometry of an integrating sphere
Sample
ρw
SamplePort (As)
DetectorPort (Ad)
EntrancePort (Ae)
Area ofSurface (As)
Baffle
F.O.V.
06_Integrating 12-13-12_06_Integrating 12/13/12 1:28 PM Page 62
63
INTEGRATINGSPHERES– R
EFLECTANCE
FROM
ALL
PERSPECTIVES
A well-designed sphere has the sample close to the spheregeometry so that the sphere will collect close to the full availablehemispherical reflectance (2π steradians). A window to separatethe sphere and sample may be important in some cases, but itwill place the sample a small distance from the sphere, therebysomewhat reducing the collected high-angle reflectance. The PIKETechnologies integrating spheres are coated with the highest possible reflective surface for the desired wavelength region. Thecoating of the surface of the sphere has to be uniform and closeto being a perfect Lambertian scatterer. These characteristicsallow the light falling in the sphere to be uniformly distributedover the entire surface of the sphere. It is also important howmuch of this light is actually collected on the detector surface.
Sphere ThroughputThe throughput of a single sphere may be defined as a functionof the hemispherical reflectance to the average spherical wallreflectance ratio. The closer the sphere surface is to idealreflectance, the higher the throughput. The detector, the sampleand the illumination require that a portion of the wall of thecomplete sphere be removed. Smaller cutouts for beam input and output result in higher energy throughput. Due to other considerations, such as reduction of light scatter from the edgesof the sphere cutouts, called ports, these have to be optimizedand cannot be too small.
The throughput can be expressed with these sphere designparameters:
Where Ad is the detector area, As is the sphere area, Pw is thesphere wall hemispherical reflectance, Pw,avg is the average spherewall reflectance.
The sphere throughput is higher if the light falling on thedetector is increased by the multiple reflections of the light.Another way of looking at the integrating sphere is that it enhancesthe detector signal by collecting the light, and if the wall surfaceis reflective enough, bounce it around until it illuminates thedetector. The factor that is used to express this gain is called thesphere multiplier (M), which is a function of the wall reflectance(Pw), the proportion of the total area of ports to the surface of thesphere (f).
The brightness of the sphere, using the same amount ofinput light flux, is dependent on the wall reflectivity, the port-to-sphere surface ratio and the size of the sphere surface.
where Φi is the input light flux and As is the area of the spherewall surface.
For the sphere the area of the sphere obviously depends onthe sphere diameter, and thus the formula shows that a smallersphere is brighter than a larger diameter one.
The sphere diameter cannot be reduced too far however,because the sample diameter will also have to be decreased proportionally when the sphere is smaller. For typical spectroscopicapplications the optimum sphere diameter is influenced by thebeam size coming from the FTIR spectrometer and the typicalsample size of 3–25 mm. Most integrating sphere modules use a2–4 inch diameter sphere to accommodate the above designparameters. In a practical design, the openings of the sphere needto be kept around 5% for optimum throughput. Wall reflectanceis usually between 95–99% and results in a sphere gain of 10–30.
Integrating Spheres for Mid-IR and NIRIntegrating spheres, although much more efficient than an opticalsystem with an equivalent detector position, still have lowerthroughput than the direct imaging optics. In the visible and NIRspectral region, where there are very good sources and excellent,high-speed detectors are readily available, the SNR is usually notlimited by the reduced light level. In the mid-IR spectral region,in order to utilize the above discussed advantages and benefits ofintegrating spheres, the reduced throughput needs to be offset bythe use of the high sensitivity, cooled detectors, such as the liquidnitrogen cooled MCT detector utilized by PIKE Technologies. Thenear-infrared and mid-infrared measurements using integratingsphere optics have different analytical and measurement goals aswell as different features. PIKE Technologies offers both mid-IRand NIR versions.
06_Integrating 12-13-12_06_Integrating 12/13/12 1:28 PM Page 63
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-274-2721
64
NOT E S
06_Integrating 12-13-12_06_Integrating 12/13/12 1:28 PM Page 64
Remote SamplingAccessoriesHollow waveguide and fiber optic sampling
accessories provide a new dimension of flexibility –
expanding the reach of the sample compartment.
The sampling probe now is flexible and may be
taken to the sample; maybe an unwieldy sample –
too large to be fit onto an accessory. PIKE
Technologies offers NIR and Mid-IR versions of
remote sampling probes.
FlexIR – NIR Fiber Optic Accessoryfor remote sampling in the NIRspectral region
Heated Liquid Sample Holder Out-of-sample compartment characterization of liquids at controlled temperatures
Page 69
FlexIR™ – Mid-IR Hollow WaveguideAccessory for remote and flexiblesampling in the Mid-IR spectral region
Page 66
Page 68
07_RemoteSamp 12-13-12_07_RemoteSamp 12/13/12 1:29 PM Page 65
The PIKE FlexIR Hollow Waveguide Accessory is an excellent toolfor remote and specific area analysis of a wide variety of samples.Visible surface contamination, small area material identificationand bulky materials too large to fit into the FTIR sample compart-ment are a few of the many samples and application types forthe FlexIR accessory.
For reaction monitoring, the accessory can be equipped witha high temperature/high pressure probe. The probe is made ofHastelloy and features two-reflection ATR diamond crystal. The6.35 mm shaft diameter and 178 mm length make it suitable foruse in a wide variety of reaction vessels. The probe maximumtemperature is 150 °C, maximum pressure up to 8.3 MPa.
The FlexIR Hollow Waveguide Accessory is designed for highthroughput, ruggedness and wide spectral range. The FlexIR utilizes a customized optical design with diamond turned focusoptics providing exceptional IR throughput. The hollow wave-guides are very durable and free from the typical fracture problemsencountered with polycrystalline core fibers. The highly reflectivehollow waveguides transmit maximum energy through the fullmid-IR spectral region – eliminating the need for multiple fibersfor complete spectrum coverage when chalcogenide or halideprobes are used.
Two FlexIR bases are available for maximum configurability.The MCT version comes with an integrated detector which offershigh sensitivity and fast data collection rates. Three detectoroptions are available to best optimize the signal-to-noise ratio(SNR) against the required spectral range and the applicationneeds. The mid-band MCT is the most versatile and commondetector offered with this version of the accessory. A DTGS FlexIRbase is available for those applications that do not require a highSNR, and benefit from the flexibility and convenience of a roomtemperature detector. To optimize its performance, the DTGSdetector is integrated into the probe. This probe is equipped witha short handle for ease of positioning and sampling.
The PIKE Technologies FlexIR Hollow Waveguide Accessory is built and tested for optimum performance for your FTIR spectrometer.
FlexIR – Hollow Waveguide Accessory for Remote Infrared Sampling
F E ATUR E S O F THE F L E X IR
• Fast, easy identification of solids and liquid samples outsideof the sample compartment
• 1 or 2 meter, hollow waveguides (HWG) offer exceptionaldurability and high throughput
• Full mid-IR spectral range coverage• ATR, specular and diffuse reflectance probes for a completearray of sampling applications
• Standard and high temperature/high pressure probes forreaction monitoring
• Permanent alignment of sampling probe to the hollow waveguide for consistent analysis results
• MCT or DTGS detector choice for maximum sensitivity and convenience
• Compatible with most FTIR spectrometers
Visible defect on manufactured product – FlexIR HWG Accessory withATR probe
PIKETECHNOLOGIES
WWW.PIKETECH.COM
608-274-2721
66
FlexIR with DTGS Accessory
Diamond ATR Probe
Adjustable andstandard HollowWaveguide probeholders
Adjustable Probe Holder
Standard ProbeHolder
07_RemoteSamp 12-13-12_07_RemoteSamp 12/13/12 1:29 PM Page 66
67
REMOTESAMPLINGACCESSORIES– E
XTENDINGYOURSAMPLECOMPARTMENT
ORDER I NG IN FORMAT I ON
FlexIR Hollow Waveguide Base with MCT DetectorPA R T NUMB E R D E S C R I P T I O N
045-30XX FlexIR Hollow Waveguide Base for MCT Version
Notes: The FlexIR is provided with base optics mounting for the sample compartmentof your FTIR spectrometer and an onboard MCT detector. Your FTIR spectrometermust be capable of interfacing with an external detector.
Hollow Waveguide MCT Detector Choice (select one or more)PA R T NUMB E R D E S C R I P T I O N
045-3200 Mid-band MCT Detector
045-3100 Narrow-band MCT Detector
Probe Choices for Hollow Waveguide with MCT Detector (select one or more)PA R T NUMB E R D E S C R I P T I O N
045-4200 Diamond ATR Probe – Basic, 1 m
045-4300 Diamond ATR Probe – High Temperature/High Pressure, 1 m
045-4100 Diamond/ZnSe ATR Probe, 1 m
045-4102 Diamond/ZnSe ATR Probe, 2 m
045-4010 ZnSe ATR Probe, 1 m
045-4012 ZnSe ATR Probe, 2 m
045-4050 Ge ATR Probe, 1 m
045-4052 Ge ATR Probe, 2 m
045-4030 Specular Reflectance Probe, 1 m
045-4032 Specular Reflectance Probe, 2 m
045-4020 Diffuse Reflectance Probe, 1 m
Notes: Sampling probes are fixed to the Hollow Waveguides for maximum samplingreproducibility. Diffuse and specular probes are open-tipped and are not suitablefor powder sampling.
FlexIR Hollow Waveguide Base with DTGS Detector PA R T NUMB E R D E S C R I P T I O N
045-35XX FlexIR Hollow Waveguide Base for DTGS Version
Notes: The FlexIR is provided with base optics mounting for the sample compartmentof your FTIR spectrometer. Your FTIR spectrometer must be capable of interfacingwith an external detector. The DTGS detector is integrated into the probe.
Probe Choices for Hollow Waveguide with DTGS Detector (select one or more)PA R T NUMB E R D E S C R I P T I O N
045-5100 Diamond/ZnSe ATR Probe, 1 m
045-5010 ZnSe ATR Probe, 1 m
045-5050 Ge ATR Probe, 1 m
045-5030 Specular Reflectance Probe, 1 m
Notes: Sampling probes are fixed to the Hollow Waveguides for maximum sampling reproducibility. DTGS detector integrated into the probe. Specular probe is open-tipped and is not suitable for powder sampling.
Hollow Waveguide Probe HoldersPA R T NUMB E R D E S C R I P T I O N
045-3400 Adjustable Probe Holder
045-3410 Standard Probe Holder
Notes: Probe holders may be used with all Standard Hollow Waveguide probes.
FLEXIR ACCESSORY SPEC IF ICAT IONS
Optical Design All reflective, diamond turned focus optics
Probe Design Hollow waveguide (HWG), full mid-IR reflective
Bend Radius, Minimum 150 mm
HWG Dimensions 1 or 2 m long, 1.6 mm OD, 1.0 mm ID
Diamond High Temperature/High Pressure ATR Probe
Probe Body Hastelloy C-276
ATR Crystal Monolithic Diamond
ATR Crystal Diameter 4.5 mm
Number of Reflections 2
Maximum Temperature 150 °C
Maximum Pressure 8.3 MPa
Shaft Dimensions Length: 178 mm, Diameter: 6.35 mm
Diamond ATR Probe – Basic
Probe Body Hastelloy C-276
ATR Crystal Monolithic Diamond
ATR Crystal Diameter 4.5 mm
Number of Reflections 2
Maximum Temperature 80 °C
Maximum Pressure 8.3 MPa
Shaft Dimensions Length: 178 mm, Diameter: 6.35 mm
Standard ATR Probes
Probe Body Handle: Aluminum Sampling Tip: Stainless Steel
Maximum Sample Depth 60 mm
ATR Crystal Types Diamond/ZnSe composite, ZnSe, and Ge
ATR Crystal Diameter 4.5 mm
Maximum Operating Diamond/ZnSe: AmbientTemperatures ZnSe: 60 °C
Germanium:60 °C
Specular Reflectance Probe Gold-coated, 20 degree AOI
Diffuse Reflectance Probe Gold-coated, 2.5 mm port
Shaft Dimensions of all Length: 102 mm, Diameter: 22 mm Standard Probes
Other Specifications
Detector Choices DTGS or MCT
Spectral Range Diffuse Mid-band: 5000–650 cm-1
and Specular Reflectance, Narrow-band: 5000–800 cm-1
MCT Model
Spectral Range ATR, ZnSe: 5000–650 cm-1
Mid Band MCT Model Ge: 5000–700 cm-1
Diamond/ZnSe: 5000–650 cm-1
Spectral Range and 5000–650 cm-1
Specular Reflectance, DTGS Model (CsI window)
Spectral Range ATR, ZnSe: 5000–650 cm-1
DTGS Model Ge: 5000–600 cm-1
Diamond/ZnSe: 5000–650 cm-1
Accessory Dimensions, 153 x 132 x 150 mmMCT Model (W x D x H) (excludes FTIR baseplate and mount)
Accessory Dimensions, 60 x 70 x 75 mmDTGS Model (W x D x H) (excludes FTIR baseplate and mount)
07_RemoteSamp 12-13-12_07_RemoteSamp 12/13/12 1:29 PM Page 67
PIKETECHNOLOGIES
WWW.PIKETECH.COM
608-274-2721
68
The PIKE FlexIR™ near-IR (NIR) Fiber Optic Accessory is an excel-lent tool for remote and speedy analysis of a wide variety of mate-rials. Powders, plastics, coatings, and liquid samples are readily measured – typically within 30 seconds. The FlexIR accessory is ideal for performing incoming QC of materials used in pharmaceutical, polymer, and chemical manufacturing.
NIR sampling is fast and efficient as it eliminates the need for sample preparation. The FlexIR accessory further speeds theanalysis since the probe tip is simply touched onto the sample,often in drums, and the spectrum is collected. Powdered samplespackaged within a plastic bag can be analyzed without removalfrom the bag and this further speeds analysis time and eliminatesanalyst exposure to chemical materials.
The PIKE Technologies FlexIR NIR Fiber Optic Accessory isdesigned for maximum throughput and performance. The fiberoptic cable is directly coupled to the integrated indium galliumarsenide (InGaAs) detector – eliminating energy loss due to additional transfer optics and beam divergence.
With the optional Liquids Sampling Tip, it is easy to identifyincoming liquids by inserting the wand tip into the liquid sampleand collecting its spectrum.
The PIKE Technologies FlexIR NIR Fiber Optic Accessory is builtand tested for optimum performance for your FTIR spectrometer.
ORDER I NG IN FORMAT I ON
FlexIR NIR Fiber Optic AccessoryPA R T NUMB E R D E S C R I P T I O N
045-10XX FlexIR NIR Fiber Optic Accessory
Notes: The FlexIR is provided with base optics mounting for the sample compartmentof your FTIR spectrometer and includes electronic cabling and diffuse reflectanceprobe. Your FTIR spectrometer must be configured with NIR beamsplitter and NIRsource for optimum performance of the FlexIR accessory. Your FTIR spectrometermust be capable of interfacing with an external detector. Please see the FTIR codesheet for your instrument designation.
FlexIR NIR Fiber Optic Accessory, Sampling OptionsPA R T NUMB E R D E S C R I P T I O N
045-2001 Liquids Sampling Tip for FlexIR, 1.0 mm pathlength
045-2000 Liquids Sampling Tip for FlexIR, 1.5 mm pathlength
045-2002 Liquids Sampling Tip for FlexIR, 2.0 mm pathlength
Notes: The Liquids Sampling Tip is screw mounted and easily exchanged with thesolids sampling tip on the FlexIR sampling wand.
Replacement PartsPA R T NUMB E R D E S C R I P T I O N
045-2010 Diffuse Reflectance Tip for FlexIR NIR Probe
F E ATUR E S O F THE F L E X IR
• Fast, easy identification of solids and liquid samples in situ• 2 meter, low-OH fibers providing exceptional throughput andexcellent spectral data with short analysis time
• Spectral range from 1.0 to 2.5 microns (10,000 to 4000 cm-1)
• Integrated, high sensitivity InGaAs detector with electronicsconnection for your FTIR spectrometer
• Standard SMA connectors providing maximum flexibilitywith fiber probes
• Standard diffuse reflectance sampling tip with inert sapphirewindow for solid samples
• Optional transflectance sampling tip for liquid samples• Compatible with most FTIR spectrometers configured for NIR operation
Spectra of incoming pharmaceutical materials measured and verifiedwith the FlexIR NIR Fiber Optic Accessory
Spectra of incoming liquid materials measured and verified with theFlexIR NIR Fiber Optic Accessory
FlexIR – NIR Fiber Optic Accessory for Fast and Remote Sample Identification
07_RemoteSamp 12-13-12_07_RemoteSamp 12/13/12 1:29 PM Page 68
69
REMOTESAMPLINGACCESSORIES– E
XTENDINGYOURSAMPLECOMPARTMENT
The PIKE Technologies Heated Liquid Sample Holder has beendesigned to provide a quick and easy way of analyzing a widerange of liquids at prescribed temperatures or a pre-programmedtemperature ramp. The accessory features an open well with integrated heating coils and digital temperature controller locatedat its base. The sampling well can be fitted with molded cups –if disposable sampling is required.
Typical measurements are performed with fiber optic probesmounted in the well and connected to mid-IR, NIR or UV-Vis spectrometer – depending on application needs. The probe isfirmly held in place while the heated sample is introduced byraising the heated cup body. This configuration providesenhanced measurement precision because energy is maintainedthrough the constrained probe fibers.
The temperature range supported by the Heated LiquidSample Holder spans from ambient to 130 °C. The accessory is most often used in analysis and quality control of oils and high-boiling liquid samples.
The temperature of the Heated Liquid Sample Holder is regulated by an integrated digital temperature controller.
ORDER I NG IN FORMAT I ON
Heated Liquid Sample HolderPA R T NUMB E R D E S C R I P T I O N
045-1100 Heated Liquid Sample Holder
Replacement PartsPA R T NUMB E R D E S C R I P T I O N
045-1106 Sample Cups (set of 6)
FEATURES OF THE HEATED LIQUID SAMPLE HOLDER
• Simplified sampling and QC of oils and viscous liquids underprescribed temperatures
• Disposable sampling cups• Temperature range – from ambient to 130 °C• Integrated digital temperature control• For mid-IR, NIR and UV-Vis fiber optic probes
Heated Liquid Sample Holder – Characterization of Liquids at Controlled Temperatures
HEATED LIQUID SAMPLE HOLDER SPEC IF ICAT IONS
Well Material Aluminum
Well Capacity 156 mL
Temperature Range Ambient to 130 °C
Accuracy +/- 0.5%
Temperature Control
Digital +/- 0.5% of set point
Input Voltage 100–240 V, auto setting
Output Voltage Variable 24 VDC/120 W max.
Dimensions (W x D x H) 140 x 190 x 330 mm
Weight 3.4 kg
Heated Liquid Sample Holder with Probe
07_RemoteSamp 12-13-12_07_RemoteSamp 12/13/12 1:29 PM Page 69
PIKETECHNOLOGIES
WWW.PIKETECH.COM
608-274-2721
70
NOT E S
07_RemoteSamp 12-13-12_07_RemoteSamp 12/13/12 1:29 PM Page 70
Microsampling Microsampling accessories make an ideal addition
to an FTIR spectrometer when you need to do
analysis of samples which are considerably
smaller than a typical 8–10 mm IR beam size.
PIKE Technologies offers microsampling accessories
which demagnify the FTIR beam to a smaller
dimension and thereby increase IR throughput
for small samples.
S84 Heated Microscope StageFor temperature measurementsunder vacuum or controlled gas flow
Page 75
Microsampling Tools Sample handling tools for microanalysis
Page 76
4X and 6X Beam CondensersFor a wide variety of transmissionmeasurements of micro samples
µMAX™ FTIR MicroscopeFor transmission, reflection andATR analysis of micro samples
Page 72
Micro Diamond CellFor compressing and holdingsamples for microanalysis
Page 77
Page 78
08_Microsampling 12-13-12_08_Microsampling 12/13/12 1:30 PM Page 71
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
72
µMAX – Sample Compartment Microscope for FTIR
The µMAX™ is an all new optical design for IR microanalysis, providing high performance sampling at low-cost with exceptionalease of use. The µMAX is designed to fit into the sample compart-ment of most FTIR spectrometers. The compact, planar opticallayout minimizes the pathlength of the IR beam and therebymaximizes IR throughput.
All operations with the µMAX are intuitive and made eveneasier with standard Dichroic Optics which provides full viewingof the sample while collecting IR spectra. With Dichroic Optics youcan view the sample area and simultaneously search for appropriateIR spectral content – greatly speeding microanalysis. The fullyvariable X, Y, θ See Thru aperture for transmission provides optimized sample dimensioning – for getting the maximum IRsignal from every sample.
The µMAX IR microscope uses 7.45X Schwartzchild objectiveand condenser to focus the IR beam onto the sample and provideexcellent sample visualization – better than 1 micron visibleimage resolution. An optional CCD camera enables video imageprojection onto the PC. With the Dichroic Optics of the µMAX andspectral preview of the FTIR software one can view changing IRspectra and sample position in real-time on the PC.
The µMAX is the first sample compartment IR microscopeaccessory capable of all microsampling modes – transmission,reflection and ATR. The µMAX fits into the sample compartment,using the spectrometers detector for convenience and samplingflexibility. For relatively larger micro samples (100 microns andgreater) the DTGS detector provides excellent performance withthe µMAX and enables full mid-IR spectral range coverage to 450 cm-1. For smaller micro samples to 20 microns in size an MCT detector is recommended.
F E ATUR E S O F THE µMAX
• Compact sample compartment design to save lab space• Uses FTIR detectors – DTGS or MCT • Available with transmission, reflection and ATR • High throughput optical design• Simultaneously view and collect spectrum• Easy-to-use, robust design• Available for most FTIR spectrometers• Low-cost
Transmission spectra of polystyrene film at aperture sizes of 200 x 200,100 x 100, and 50 x 50 microns using the µMAX IR Microscope using theDTGS detector of the FTIR spectrometer. Spectra were collected using 4 cm-1 spectral resolution and 2 minute collection time.
Transmission spectra of polymer laminate sample using DTGSdetector. Samples held in PIKE Micro Compression Cell.
PIKE Technologies MicroCompression Cell
08_Microsampling 12-13-12_08_Microsampling 12/13/12 1:30 PM Page 72
73
MICROSAMPLING
– F
ROM
MICRONS
TO
MILLIM
ETERS
Switching from transmission to reflection on the µMAX is easywith a thumb wheel selection. Reflection sampling area is definedby use of the aperture slide with pre-defined sizes from 40 to 1000microns. Micro reflection analysis of small areas of interest onreflective surfaces is made easy with the PIKE Technologies µMAX.Simply focus and position the sampling stage, select the samplearea with the aperture slide and collect the spectrum. The back-ground spectrum is collected using the same dimension apertureusing the gold surfaced reference slide.
ATR is an excellent sampling option for the µMAX IR microscope.The RotATR™ is a unique, rugged pivot designed germanium ATRproviding easy and precise operation and excellent micro ATR spectra.Focus and select the sample area, rotate the ATR crystal into sample position, make sample contact and collect the IR spectrum.
Micro ATR works exceptionally well with the µMAX IR microscope. The 100 micron flat-tipped micro ATR crystal makesintimate contact with the sample easily achieved, providing highspectral quality as seen in the data above.
The Micro Diamond Cell is an excellent option for use withthe µMAX IR Microscope. Tiny chips or fiber segments can be flattened to obtain excellent transmission spectra.
Micro reflection spectrum of a coating on a reflective base metal, 200 x 200 micron sampling area using DTGS detector
Micro ATR spectra of a 40 micron carpet fiber (upper – blue) and a 50 micron caffeine crystal (lower – red) using DTGS detector
Single drug crystal identified as benzocaine flattened in Micro DiamondCell. Data collected using DTGS detector
µMAX SPEC IF ICAT IONS
Sampling Modes Transmission, Reflection and ATR
Objective 7.45X Schwartzchild, N.A. 0.64, fixed for sturdy, permanent alignment
Optional Condenser 7.45X Schwartzchild, N.A. 0.64, Z-adjust to optimize sample focus
Micro ATR RotATR with 100 micron tip, pivot pinned-in-placeand easily removable for maximum sample areaaccess. Universal Ge crystal for analysis of allmicro samples.
Sample Stage Z focus including X, Y slide sample holder, with 20 x 50 mm travel
IR Collection/Sample Dichroic Optics reflect IR energy and transmit visible,Viewing providing continuous view of the sample during
data collection. Dichroic Optics eliminate the need toswitch optics from view sample to collect spectrum.
Sample Masking X, Y, θ variable Glass Aperture for transmissionsampling to view sample and surrounding sample area. Standard pinhole aperture slide forreflection sampling.
Illumination Köhler, variable intensity, 50 watt
Sample Viewing Binocular or Trinocular Viewer with 10X eyepieces.Standard eyepiece reticule for sample dimensioning,optional Video Camera with USB interface.
Visible Field of View 1600 microns
Visible Image Contrast Better than 1 micron
Station In sample compartment, fits most FTIR spectrometers. Mounted on a baseplate for theFTIR spectrometer.
Detector Uses standard detectors of the FTIR, typically DTGS and MCT
Purge Includes purge tubes and purge inlet for additional purge. Compatible with sealed and desiccated FTIR spectrometers.
Regulatory RoHS and CE Mark compliant
Please contact PIKE Technologies for additional product detail.
Micro Diamond Cell
08_Microsampling 12-13-12_08_Microsampling 12/13/12 1:30 PM Page 73
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
74
Bundled µMAX PackagesP A R T N U M B E R D E S C R I P T I O N
034-21XX Complete µMAX Sample Compartment IR Microscope with Transmission, Reflection, ATR and video camera
034-22XX µMAX Sample Compartment IR Microscope withTransmission, Reflection and ATR
034-41XX Complete µMAX Sample Compartment IR Microscope for Reflection, ATR and video camera
034-42XX µMAX Sample Compartment IR Microscope with Reflection and ATR
Notes: All bundled µMAX Packages include a trinocular viewer, slide aperture forreflection, X, Y sample stage, micro sampling kit, spectrometer base mount, purgetubes and storage case. The transmission versions include the X, Y Variable See Thruaperture. Please see the FTIR instrument code sheet.
Configurable µMAX Systems
µMAX Base OpticsP A R T N U M B E R D E S C R I P T I O N
034-20XX µMAX Sample Compartment IR Microscope for Transmission and Reflection (ATR optional)
034-40XX µMAX Sample Compartment IR Microscope for Reflection (ATR optional)
Notes: The µMAX Sample Compartment IR Microscope is available in versions fortransmission and reflection sampling or refection only – both versions are also compatible with ATR sampling. RotATR µMAX ATR must be purchased separately.Both versions include the slide aperture for reflection, X, Y sample stage, micro sampling kit, spectrometer base mount, purge tubes, and storage case. The transmission version includes the X, Y Variable See Thru aperture. Please see the FTIR instrument code sheet.
Sample Viewing Options (must select one or more)P A R T N U M B E R D E S C R I P T I O N
034-3020 Binocular Viewer for µMAX
034-3030 Trinocular Viewer for µMAX
034-3010 Video Camera for µMAX
Notes: Trinocular Viewer is required for selection of the Video Camera option.Binocular and Trinocular Viewers include adjustable reticule to assist with sampledimensioning.
Micro ATR (optional)P A R T N U M B E R D E S C R I P T I O N
034-3040 RotATR, µMAX ATR, Ge Crystal
Notes: The RotATR micro ATR is compatible with the µMAX Sample Compartment IR Microscope.
Sampling Options, Upgrades and Replacement Parts
Micro Sampling OptionsP A R T N U M B E R D E S C R I P T I O N
034-3060 Micro Compression Cell for 13 mm IR Transparent Windows
160-1135 13 mm x 2 mm KBr Window
162-0030 Micro Plane with Carbide Blade
162-0040 Micro Plane with Diamond Blade
162-0010 Micro Diamond Cell 1.6 mm
162-0020 Micro Diamond Cell 2.0 mm
µMAX IR Microscope UpgradesP A R T N U M B E R D E S C R I P T I O N
034-0090 µMAX IR Microscope Transmission Upgrade
Notes: The Transmission Upgrade requires shipment of the accessory to PIKETechnologies. The upgrade includes the µMAX condenser, the X, Y Variable See ThruAperture, and all additional optics required for transmission, reflection and optionalATR sampling.
µMAX IR Microscope Replacement PartsP A R T N U M B E R D E S C R I P T I O N
300-0025 13 mm Gold Surfaced Disk for Reflection Analysis
034-3070 IR Microsampling Kit (3-position sample slide with gold mirror,2 KBr windows, scissors, tweezers, probes and roller knifewith replacement blades)
162-6401 3-position Sample Slide for 13 mm Windows
300-0002 Gold Surfaced Sample Slide
034-3080 Replacement Illumination Bulb for µMAX
Notes: For options not listed here, please contact PIKE Technologies.
ORDER I NG IN FORMAT I ON
08_Microsampling 12-13-12_08_Microsampling 12/13/12 1:30 PM Page 74
75
MICROSAMPLING
– F
ROM
MICRONS
TO
MILLIM
ETERS
The S84 Microscope Heat Stage is designed for spectroscopicanalysis and monitoring of small samples at varying temperatures.The accessory can be located directly on the sampling stages ofmost FTIR and Raman microscopes. It can be also used for trans-mission measurements when placed in the sample compartmentof the spectrometer.
The stage features a lightweight aluminum body that is 19.5 mmthick. The sample is located between two IR transparent windows(transmission measurements) or between the IR reflecting mirrorand single window (trans-reflection configuration). Samples canbe easily loaded and removed by unscrewing the upper windowplate by hand, or with a special tool provided with the product.Optional inserts for varying sample sizes and shapes are availableand a wide selection of window materials can be used with the stage.
The accessory can be used under ambient conditions orunder vacuum. In addition, inert or reaction gas can be flowedthrough the stage chamber. Valves and connectors required forthese special configurations should be ordered separately.
Temperature range of the S84 Microscope Heat Stage spansfrom ambient to 500 °C, and is controlled with +/- 0.5% accuracyby digital controllers available in PC or dedicated configurations.PC option provides graphical parameter setup, ramping and USBconnectivity. Liquid cooling is integrated into the accessory basein order to minimize heat transfer to the microscope stage, improve temperature stability and aid the cooling process.
F E ATUR E S O F S84 M I C RO S COP E HEAT S TAG E
• Compact design fits most stages of FTIR and Raman microscopes• Feasible for direct transmission measurements in samplecompartments of FTIR spectrometers
• Precise temperature control up to 500 °C• Vacuum, reaction gas or inert gas chamber environment• Easy sample loading, assembly and disassembly
S84 MICROSCOPE HEAT STAGE SPEC IF ICAT IONS
Stage Body Aluminum
Aperture Maximum: 4 mm, Minimum: 1 mm
Chamber Window 20 mm x 2 mm
Sample Port Window 13 mm x 1 mm
Leak Rate Less than 1 x 10-9 Pa/m3 per second
Gas Connection 1/16" Swagelok®
Coolant Connection 4 mm quick connection
Stage Dimensions (W x D x H) 84 x 100 x 19.5 mm
Stage Weight 0.5 kg
Temperature Control Resistive heating
Temperature Range Ambient to 500 °C
Accuracy +/- 0.5%
Sensor Type Type K thermocouple
Temperature Controllers
Digital +/- 0.5% of set point
Digital PC +/- 0.5% of set point, graphical setup, up to10 ramps, USB interface
Input Voltage 90–264 V, auto setting, external power supply
Output Voltage Variable 40 VDC/80 W max.
Controller Dimensions 125 x 200 x 60 mm(W x D x H)
ORDER I NG IN FORMAT I ON
P A R T N U M B E R D E S C R I P T I O N
162-4184 S84 Microscope Heat Stage
Notes: S84 Heat Stage includes 20 x 2 mm Window Mount, 13 x 1 mm ReferenceMirror, Teflon Tubing (gas), Urethane Tubing, and 5/16" Wrench
Temperature Controllers (must select one)P A R T N U M B E R D E S C R I P T I O N
076-2440 S84 Digital Temperature Controller – PC Control
076-2240 S84 Digital Temperature Controller
Windows (must select)(1) 20 x 2 mm and (1) 13 x 1 mm for Reflection Measurement (2) 20 x 2 mm and (1) 13 x 1 mm for Transmission MeasurementP A R T N U M B E R D E S C R I P T I O N
160-1134 KBr Disk (20 x 2 mm)
160-1148 BaF2 Disk (20 x 2 mm)
160-1144 CaF2 Disk (20 x 2 mm)
160-5003 KBr Disk (13 x 1 mm)
160-1149 BaF2 Disk (13 x 1 mm)
160-5001 CaF2 Disk (13 x 1 mm)
Options and Replacement Parts for Transmission/Reflection S84 Microscope Heat StageP A R T N U M B E R D E S C R I P T I O N
162-4105 Plate for Motorized Microscope Stage*
162-4106 2" x 3" Slide Mount for Transmission Measurements
162-4107 Holder for 1, 2, 3 mm diameter samples
162-4108 32 x 3 mm Window Mount
162-4109 Gas Valve 1/16" (Gas Connection) – 2 needed
162-4110 Quick Connector (for external circulating liquid) – 2 needed
162-4111 Reference Mirror (13 x 1 mm)
170-1000 Liquid Recirculator
*Must provide information for microscope make and model
Compact Transmission/Reflection S84 Microscope Heat Stage –High Temp Measurements under Vacuum or Controlled Gas Flow
LiquidRecirculator
08_Microsampling 12-13-12_08_Microsampling 12/13/12 1:30 PM Page 75
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
76
Microsampling Tools – Compression Cells and Sample Manipulation
ORDER I NG IN FORMAT I ON
Microsampling ToolsP A R T N U M B E R D E S C R I P T I O N
034-3060 Micro Compression Cell (requires selection of two 13 x 2 mm windows)
160-1135 13 x 2 mm KBr Window, 1 each
160-1008 13 x 2 mm KBr Windows, 6 pack
162-0030 Micro Plane with Carbide Blade
162-0040 Micro Plane with Diamond Blade
162-6401 3-Position Sample Slide (recommended selection of window or disk)
300-0025 13 x 2 mm Gold-Surfaced Disk
034-3070 IR Microsampling Kit (3-position sample slide with gold mirror, 2 KBr windows, scissors, tweezers, probes and rollerknife with replacement blades)
Notes: For items not in this list please contact PIKE Technologies.
PIKE Technologies Micro Compression CellThe Micro Compression Cell is an excellent sampling tool for supporting small samples for transmission analysis with the PIKEµMAX IR microscope. Single crystals, flattened fibers, multi-layerpolymer micro samples are firmly supported between salt windows – typically KBr for transmission analysis. The cell uses 13 x 2 mm windows and has a clear aperture of 10 mm. Compressionof the sample is achieved by rotation of the knurled retainer.
Micro Plane with either Carbide or Diamond BladeThe Micro Plane is a useful tool for preparation of thin slices ofmulti-layered samples for transmission microanalysis. The MicroPlane is available with either carbide or diamond blade. The carbide blade is recommended for general polymer materials.The diamond blade is recommended when the multi-layeredsample has metallic content. The Micro Plane features anadjustable knife edge to control the thickness of the sample.
PIKE Technologies 3-Position Sample SlideThe PIKE 3-Position Sample Slide is designed for placement of 13 mm windows for transmission analysis or the 13 mm gold-surfaced disk for reflection analysis when using the µMAX IRMicroscope. An open port of the 3-Position Sample Slide is usedconveniently to support a flattened free-standing fiber fortransmission analysis.
08_Microsampling 12-13-12_08_Microsampling 12/13/12 1:30 PM Page 76
77
MICROSAMPLING
– F
ROM
MICRONS
TO
MILLIM
ETERS
Small samples are easily held in place and flattened to idealthicknesses for FTIR analysis using the PIKE Technologies MicroDiamond Cell. The diamond windows in this cell are Type IIA synthetic for excellent transmission from the UV through Far-IRspectral regions. The hardness of diamond enables maximumpressure to be applied to all types of crystalline, fiber, or amor-phous materials. Typical samples include fibers, paint chips, rubbers, and plastic materials including laminates.
The large clear aperture of the PIKE Technologies MicroDiamond Cell (either 1.6 or 2.0 mm) makes it easy to place themicro sample into position while viewing under a stereomicroscope.The large thumb wheels provide easy means of tightening andflattening the samples.
The PIKE Technologies Micro Diamond Cell is mounted on astandard 2" x 3" plate compatible with your FTIR spectrometersample compartment. However, it performs best with a beamcondenser or IR microscope.
Micro Diamond Cell – For Compressing and Holding Samples for Microanalysis
F E ATUR E S O F THE M I C RO D I AMOND CE L L
• Compression and positioning for micro samples• 1.6 or 2.0 mm clear aperture versions• Easy thumb wheel mechanism for application of pressure• Compatible with UV to Far-IR spectral regions • Compatible with PIKE µMAX IR microscope and PIKE beam condensers
• 14,000 psi pressure (10 kgf/mm2)
Human hair sample flattened in the PIKE Diamond Cell and analyzedusing the µMAX IR microscope
ORDER I NG IN FORMAT I ON
Micro Diamond CellP A R T N U M B E R D E S C R I P T I O N
162-0010 Micro Diamond Cell, 1.6 mm
162-0020 Micro Diamond Cell, 2.0 mm
Notes: The Micro Diamond Cell is easily laid onto the X, Y stage of the PIKE µMAX IRmicroscope. Mounting the Micro Diamond Cell into the PIKE beam condensersrequires the optional slide holder.
08_Microsampling 12-13-12_08_Microsampling 12/13/12 1:30 PM Page 77
Basic beam condenser products have been available for many years.The PIKE Technologies Beam Condenser Accessories provide allthe functionality of these basic systems with exceptional opticaldesign and easy access to the sampling area. The unique enclosedoptics provide a purged environment.
Beam condensers offer easy transmission sampling with mini-mal sample preparation. The PIKE Technologies beam condensersare available in 4 and 6 times beam de-magnification. The systemdesign incorporates a layout of six mirrors, adjustable input andoutput mirrors and two matched 4:1 (or 6:1) ellipsoidal mirrors.Each offer a large working area to accept many types of transmis-sion sampling accessories, including high pressure diamond cells,liquid cells, mull cells, and miniature micro holders. The samplearea uses pins to ensure accurate and reproducible accessoryalignment requiring no further adjustment.
For the most demanding applications, a precision X, Y, ZSampling Stage is available as an option, which accommodates all sampling accessories to achieve the highest possible opticalthroughput and allows a point-by-point surveying an extendedsample.
Sample Holders for the PIKE Technologies Beam Condensers.Left to right; Universal Spring Sample Holder – ideal for smallspheres and gems, Magnetic Sample Holder – ideal for 1 or 3 mmpellet die, and the Micro KBr Pellet and Mull Holder – ideal for very small volume solids, liquids and paste samples (holds 13 mm windows).
Either the 4X or 6X beam condensers are available in standardor gold-coated optics for high performance mid-IR for near-IRoperation.
Beam Condensers – 4X and 6X Versions for FTIR
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
78
FEATUR E S O F B EAM CONDEN S E R S
• 4X and 6X versions – providing improved spectral data formicro sampling
• High optical throughput – beam condensing optics providehigher signal-to-noise ratio for small samples
• Standard pin mounting for sample holders – providing a precise, reproducible mount for samples
• Standard sample holder block and alignment pinhole (1.5 mm)• Optional universal spring sample holder, X, Y, Z adjustablestage, micro pellet and mull holder, and magnetic sample holder
• Purge enclosed accessory – includes purge tubes and purgeinlet for additional purge.
• Compatibility with most FTIR spectrometers
Wing of fruit fly within 1 mm aperture with and without use of a beam condenser
Beam Condenser Optical Diagram
BEAM CONDENSERS SPEC IF ICAT IONS
Optics All reflective, aluminum – standardgold-coated – optional
Configurations 4X and 6X de-magnifications
Sampling Options Standard sample holdersXYZ adjustable stagePressure diamond cells and micro holders
Purgeable Yes
Dimensions (W x D x H) 165 x 242 x 114 mm (4X)165 x 318 x 114 mm (6X)
FTIR Compatibility Most, specify model and type
08_Microsampling 12-13-12_08_Microsampling 12/13/12 1:30 PM Page 78
79
MICROSAMPLING
– F
ROM
MICRONS
TO
MILLIM
ETERS
Beam CondensersP A R T N U M B E R D E S C R I P T I O N
031-40XX 4X Beam CondenserIncludes the Non-Adjustable Sample Position, 1.5 mm alignment aperture, purge tubes and mount for the FTIR of your selection.
031-60XX 6X Beam CondenserIncludes the Non-Adjustable Sample Position, 1.5 mm alignment aperture, purge tubes and mount for the FTIR of your selection.
Notes: Please select the XX code from the fold-out on the last page of this catalog.
Adjustable Sample Position (optional)P A R T N U M B E R D E S C R I P T I O N
031-2010 X, Y, Z Adjustable Sample Position
Notes: The X, Y, Z Adjustable Sample Position can be easily exchanged with theNon-Adjustable Sample Position.
Sample Holders (optional)P A R T N U M B E R D E S C R I P T I O N
031-2030 Universal Spring Sample Holder
031-2040 Magnetic Sample Holder
031-2050 Micro KBr Pellet and Mull Holder
Notes: All of these Sample Holders fit to the pin position of either the Non-Adjustable Sample Position or the X, Y, Z Adjustable Sample Position.
Micro Diamond Cell (optional)P A R T N U M B E R D E S C R I P T I O N
162-0010 Micro Diamond Cell, 1.6 mm
162-0020 Micro Diamond Cell, 2.0 mm
031-2070 Holder for Micro Diamond Cell
Notes: The Micro Diamond Cell includes the anvil pressure cell assembly, and Type IIa diamonds. Holder is required for use with beam condenser.
Beam Condenser Replacement PartsP A R T N U M B E R D E S C R I P T I O N
031-2020 Non-Adjustable Sample Position
Notes: For options not listed here, please contact PIKE Technologies.
ORDER I NG IN FORMAT I ON
08_Microsampling 12-13-12_08_Microsampling 12/13/12 1:30 PM Page 79
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
80
NOT E S
08_Microsampling 12-13-12_08_Microsampling 12/13/12 1:30 PM Page 80
Transmission Sampling Transmission sampling techniques may be applied
to a very wide range of sample types including
liquids, solids and gases. Application of automation
technology to traditional transmission sampling
can improve sample throughput and improve
sampling precision.
Transmission Sampling TechniquesTheory and Applications
Page 111
Liquid CellsFor comprehensive liquids sampling
Page 86
Dies, Presses, Grinders and AccessoriesFor comprehensive solids analysis
Page 95
Holders, Windows and Polishing KitFor optimizing transmission sampling
Page 103
Short-Path, Long-Path, and Heated Gas CellsFor comprehensive gas sampling
Page 107
Automated Vertical AccessoriesMulti-SamplIR™ and RotatIR™
Page 82
Automated Horizontal Multi-Sample SystemHigh capacity sampling
Page 84
X, Y AutosamplerFor high throughput micro-titer format sampling
Page 85
09_Transmission 12-13-12_09_Transmission 12/13/12 1:31 PM Page 81
Transmission Multi-SamplIR –Automated In-Sample Compartment Accessory
The PIKE Technologies Transmission Multi-SamplIR accessory isdesigned to speed FTIR analysis. The accessory accommodates upto 18 samples (depending on sampling plate configuration) forunattended analysis. Flexible test sequences are easily definedand automatically implemented. This Multi-SamplIR is ideal foranalyzing a wide range of materials, including films, slides, pellets,windows and large area samples like multilayer coated substrates.
Samples are conveniently mounted onto a sampling plateand held in place during the analysis. The plates can be configuredfor different sample quantities, types and geometries. The systemcan be set to perform automated mapping of the sample, producingtransmission spectra as a function of position. Sampling platesare easily mounted on the support ring with spring-loaded clips,ensuring that the plate remains precisely located and correctlyregistered. The support ring mounts on the accessory’s drive andis rotated and translated laterally through a distance of 75 mm toproduce an R-theta motion covering the entire sampling range ofthe accessory.
Each system incorporates two precision stepper motors forrotation and translation of the plate. The motors are driven bythe PIKE Motion Control Unit.
The operation is managed by PIKE Technologies AutoPROsoftware, which provides full user programmability and easy tolearn “point-and-click” environment. Polar or X, Y coordinatesmay be used to define test points. AutoPRO software allows complex test sequences to be set up, stored as methods andimplemented with full flexibility. The Motion Control Unit incorporates a smart power supply and works with 85–265 VAC,47–63 Hz power lines.
The Transmission Multi-SamplIR accessory is designed to fitmost FTIR spectrometers. Please contact us for more product details.
82
FEATUR E S O F THE MULT I - S AMP L IR
• In-compartment automated transmission sampling• Selectable number of samples, size, configuration and placement
• Multiple point analysis on single sample• Custom sampling plates and blanks• Fully automated and manual versions available
ORDER I NG IN FORMAT I ON
Transmission Multi-SamplIR (select one)PA R T NUMB E R D E S C R I P T I O N
074-26XX Automated Transmission Multi-SamplIR for FTIRIncludes: AutoPRO Software and a Motion Control Unit (85–265 VAC), and a Standard Sampling Plate for 13 mm pellets (18 positions)
Notes: This accessory requires a minimum FTIR beam height of 3.5". Insert FTIRcode found on fold-out on last page of this catalog.
Transmission Multi-SamplIR OptionsPA R T NUMB E R D E S C R I P T I O N
074-3661 Additional Standard Sampling Plate
Notes: If you need options not described here, please contact us.
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
09_Transmission 12-13-12_09_Transmission 12/13/12 1:31 PM Page 82
RotatIR – Automated Rotating Sample Stage
The PIKE Technologies RotatIR is designed for automated selectionof the angle of transmission of the sample relative to the IR beamin the FTIR sample compartment. Applications include the studyof sample thickness and sample reflectivity. Selection of the angle of transmission is automated through the use of PIKE TechnologiesAutoPRO software, the Motor Control Unit and the integratedstepper motor. A full set of spectra may be collected automaticallyby pre-defining the angles from AutoPRO software.
The RotatIR features a standard 2" x 3" slide mount for easypositioning of different types of transmission sample holders.
AutoPRO software allows complex test sequences to be setup,stored as methods and implemented with full flexibility. TheMotion Control Unit incorporates a smart power supply and workswith 85–265 VAC, 47–63 Hz power lines.
The PIKE RotatIR accessory is designed to fit most FTIR spectrometers. Please contact us for more product details.
83
TRANSMISSION
SAMPLING– A
UTOMATED
ANDMANUALTECHNOLOGIES
F E ATUR E S O F THE ROTAT IR
• Automated selection of angle of sample transmission• Programmable from 0 to 360 degrees with resolution of 0.2 degrees
• Automated collection of spectra at the defined angle of transmission via AutoPRO software
• Compatible with most FTIR systems
AutoPRO software provides interface for automated collection of spectral data
ORDER I NG IN FORMAT I ON
RotatIR Automated Rotating Sample StagePA R T NUMB E R D E S C R I P T I O N
091-20XX RotatIR Automated Rotating Sample StageIncludes: AutoPRO Software and a Motion Control Unit (85–265 VAC)
Notes: Insert FTIR XX code found on the fold-out on the last page of this catalog.
RotatIR OptionsPA R T NUMB E R D E S C R I P T I O N
162-5400 Film Sampling Card – 20 mm clear aperture, 10 each
Notes: If you need options not described here, please contact us.
09_Transmission 12-13-12_09_Transmission 12/13/12 1:31 PM Page 83
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
84
Automated Horizontal Transmission Accessories – For Films or Pellets
PIKE Technologies offers Automated Horizontal TransmissionAccessories for increasing sample throughput for analysis of filmsand pellet samples.
The Automated Horizontal Transmission Accessories are available in an 8" or a 12" version depending upon sample loadingrequirements. The 8" version will accommodate up to 37–25 mmdiameter samples. The 12" version will accommodate up to 83–25 mm diameter samples. PIKE Technologies custom manufacturessampling plates to meet your exact sampling needs. Please contactus for other configurations.
Both the 8" and 12" versions of the Automated HorizontalTransmission Autosamplers also can do specular reflection analysisif your applications require.
PIKE Technologies Automated Horizontal TransmissionAccessories are compatible with most FTIR spectrometers.
F E ATUR E S O F THE AUTOMAT ED HOR I ZONTA LTRAN SM I S S I ON AC C E S S ORY
• Fully automated transmission analysis of polymer films,pellets or other transmission samples for FTIR
• Standard specular reflectance sampling• Sampling capacity of up to 114 samples, depending upon size• Continuous operation with multiple plates• Purgeable optical design for high quality FTIR spectra
The PIKE Autosamplers are controlledby AutoPRO software, with a point-and-click user environment to definesampling positions
ORDER I NG IN FORMAT I ON
PA R T NUMB E R D E S C R I P T I O N
075-28XX Automated 8" Horizontal Transmission AccessoryIncludes: Motion Control Unit (85–265 VAC), AutoPRO Software and one 37 Position Sampling Plate
076-28XX Automated 12" Horizontal Transmission AccessoryIncludes: Motion Control Unit (85–265 VAC), AutoPRO Software and one 83 Position Sampling Plate
Notes: Please select XX code from the fold-out on the last page of this catalog.
OptionsPA R T NUMB E R D E S C R I P T I O N
075-3881 Additional Sampling Plate for 8" Automated Horizontal Transmission Accessory
076-3881 Additional Sampling Plate for 12" Automated HorizontalTransmission Accessory
Notes: For options not shown here, please contact PIKE Technologies.
09_Transmission 12-13-12_09_Transmission 12/13/12 1:31 PM Page 84
85
TRANSMISSION
SAMPLING– A
UTOMATED
ANDMANUALTECHNOLOGIES
X, Y Autosampler – Transmission and Reflection, AutomatedSampling in Microplate Format
The PIKE Technologies X, Y Autosampler is designed around standard 24, 48 or 96-well microplate architectures – ideal forhigh efficiency sample loading and FTIR analysis. The loading traymoves to a position outside of the accessory for easy loading andunloading of samples while conserving the purge. This also permitsinterface to a robot/autoloader.
Applications include high throughput analysis of liquid residuesand chemical reactions, powdered samples, and automated diffusereflection analysis. The X, Y Autosampler is available with standardall-reflective optics or with gold-coated optical components forhighest performance in mid-IR and optimized NIR sampling.
The Autosampler features an X, Y stage with both axes drivenby high precision servo motors with optical encoders for speedand reproducibility. USB and DC power are the only external connections required for this accessory. The transmission optionrequires an external IR detector port.
Programming and control of the X, Y Autosampler is donethrough PIKE Technologies’ AutoPRO software, which can be integrated easily with most FTIR software packages.
The optical design of the X,Y Autosampler is based upon aprecision ellipsoidal reflector. The size of the spot illuminated at the sample is approximately 2 mm – ideal for up to 96-wellconfigurations. The accessory is compatible with most brands and models of FTIR spectrometers.
A special silicon well plate is available for sample analysisby transmission. This unique 96-well plate allows collection of transmission spectra in mid-IR range. For diffuse reflectionmeasurements a dedicated plate is available. The plate features96 polished cavities for placement of powder samples. Pleasecontact PIKE Technologies if you require specialized samplingplate configurations.
High quality FTIR spectra ofsolvent residuescollected with the X, Y Autosampler
ORDER I NG IN FORMAT I ON
PA R T NUMB E R D E S C R I P T I O N
047-21XX X, Y Autosampler – Diffuse Reflectance ConfigurationIncludes: AutoPRO Software and 96-Well Diffuse Reflectance Sampling Plate
047-61XX X, Y Autosampler – Diffuse Reflectance Configuration with Gold-Coated OpticsIncludes: AutoPRO Software and 96-Well Diffuse ReflectanceSampling Plate
047-22XX X, Y Autosampler – Diffuse Reflectance/Transmission ConfigurationIncludes: AutoPRO Software, integrated DTGS detector, 96-Well Diffuse Reflectance and 96-Well Transmission Sampling Plates
047-62XX X, Y Autosampler – Diffuse Reflectance/TransmissionConfiguration with Gold-Coated OpticsIncludes: AutoPRO Software, integrated DTGS detector, 96-WellDiffuse Reflectance and 96-Well Transmission Sampling Plates
Notes: Replace XX in part number with code for your spectrometer listed on the last page of this catalog. For other options please contact PIKE Technologies. Fortransmission option your spectrometer must be capable of interfacing with anexternal detector.
X,Y Autosampler OptionsPA R T NUMB E R D E S C R I P T I O N
073-9110 96-Well Diffuse Reflectance Sampling Plate
073-9130 96-Well Transmission Sampling Plate
X, Y AUTOSAMPLER SPEC IF ICAT IONS
Optics Elliptical – 3X beam de-magnification
Accuracy +/- 25 µm
Mechanical Specifications
Repeatability +/- 5 µm
Resolution 1 µm
Minimum Run Time 56 seconds for 96-well plate (Actual time isspectrometer and application dependent)
Computer Interface USB
Dimensions (W x D x H) 5.55 x 13.2 x 6.25" (including micrometer)
Weight 10 lbs
F E ATUR E S O F THE X ,Y AU TO S AMP L E R
• Complete hardware and software package for automatedanalysis with standard 24, 48, or 96-well plates. Special configurations available.
• Diffuse reflectance of powdered samples or specularreflectance sampling for reaction residues
• Gold-coated optics version for highest performance mid-IRand NIR sampling
• Optional transmission sampling with integrated DTGS detector and transmission sampling plates
• Fully enclosed, purgeable design with CD-style loading tray• In-compartment mounting, compatible with most FTIR spectrometers
09_Transmission 12-13-12_09_Transmission 12/13/12 1:31 PM Page 85
Press-On Demountable Cell – For Viscous Liquids and Mulls
The PIKE Technologies Press-On Demountable Liquid Cell is recommended for fast and convenient qualitative analysis of viscous liquids and mull samples. Simply spot the sample onto the middle of the transparent IR window and slip the second window over the top. The windows are conveniently held in placeby the friction fit of the Demountable Cell Holder. The Press-OnDemountable Cell is available in 2 sizes – 25 mm and 32 mm andhas optional Teflon spacers to assist with sampling pathlength. Awide variety of window types and spacer pathlengths are availableto cover mid-IR, NIR, and far-IR spectral regions and sample composition from organic to aqueous.
The PIKE Technologies Press-On Demountable Liquid Cell isdesigned with a standard 2" x 3" plate for use with all FTIR spectrometers.
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
86
FEATURES OF THE PRESS-ON DEMOUNTABLE CELL
• Flexible window selection for optimizing spectral range and sample compatibility
• Demountable cell design for optimal cleaning of difficult samples
• Compatible with all FTIR spectrometers
ORDER I NG IN FORMAT I ON
Press-On Demountable Liquid Cell HoldersPA R T NUMB E R D E S C R I P T I O N
162-3600 Press-On Demountable Liquid Cell Holder for 25 mm WindowsIncludes: cell holder, and o-ring
162-3610 Press-On Demountable Liquid Cell Holder for 32 mm WindowsIncludes: cell holder, and o-ring
Press-On Demountable Liquid Cell Windows (select minimum of 2)PA R T NUMB E R
D E S C R I P T I O N 2 5 X 4 MM 32 X 3 MM
BaF2 160-1217 160-1147
CaF2 160-1211 160-1143
Ge 160-1138 160-1137
KBr 160-1133 160-1132
KRS-5 160-1127 160-1126
NaCl 160-1124 160-1122
Polyethylene 160-5214 160-5216
Si 160-1116 160-1159
ZnSe 160-1114 160-1113
Notes: For window compatibility please consult the Materials Properties informationon page 113 of this catalog. For additional window selections please see page 104.
Press-On Demountable Liquid Cell Spacers (Optional)PA R T NUMB E R
PAT H L E N G T H (MM ) 2 5 MM 32 MM
0.015 162-1110 162-1210
0.025 162-1120 162-1220
0.050 162-1130 162-1230
0.100 162-1140 162-1240
0.200 162-1150 162-1250
0.500 162-1160 162-1260
1.000 162-1170 162-1270
Assortment 162-1190 162-1290
Notes: Spacer pathlength packages above include 12 each of the spacers. The assortment package includes 2 each of the different pathlengths.
Press-On Demountable Liquid Cell Replacement PartsPA R T NUMB E R D E S C R I P T I O N
162-3621 Viton® O-Rings, 25 mm (12 each)
162-1330 Viton O-Rings, 32 mm (12 each)
Notes: For other options for the Press-On Demountable Liquid Cell, please contactPIKE Technologies.
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 86
Demountable Liquid Cells – For Versatile Pathlength Liquid Sampling
The PIKE Technologies Demountable Liquid Cell is ideal for qualitativeand quantitative analysis of liquid samples where it is desirableto optimize the pathlength for varying samples. Furthermore theDemountable Liquid Cell is well suited for samples where it isuseful to disassemble the cell for cleaning. A wide variety of window types and spacer pathlengths are available. Window typesare available to cover mid-IR, NIR, and far-IR spectral regions andsample composition from organic to aqueous.
The PIKE Technologies Demountable Liquid Cell is designedwith a standard 2" x 3" plate for use with all FTIR spectrometers.The needle plate includes Luer-Lok™ fittings for easy syringe filling of the sample. The window size is 32 x 3 mm and the clear aperture of the cell is 13 mm.
87
TRANSMISSION
SAMPLING– A
UTOMATED
ANDMANUALTECHNOLOGIES
FEATURES OF THE DEMOUNTABLE LIQUID CELL
• Flexible window selection for optimizing spectral range and sample compatibility
• Flexible pathlength to optimize sample absorbance• Demountable cell design for optimal cleaning of difficult samples
• Compatible with all FTIR spectrometers• Heated version available (see page 90)
Demountable liquid cell assembly layout
ORDER I NG IN FORMAT I ON
Demountable Liquid Cell Holder PA R T NUMB E R D E S C R I P T I O N
162-1100 Demountable Liquid Cell HolderIncludes: cell holder, gaskets, and one complete set of spacers – select windows below
Notes: Requires selection of windows – below. Please select 2 syringes below for filling the demountable liquid cell.
Demountable Liquid Cell Windows (must select minimum of 1 Plain and 1 Drilled)
PA R T NUMB E R
D E S C R I P T I O N P L A I N DR I L L E D
BaF2 160-1147 160-1146
CaF2 160-1143 160-1142
Ge 160-1137 160-1136
KBr 160-1132 160-1131
KRS-5 160-1126 160-1125
NaCl 160-1122 160-1121
Polyethylene 160-5216 160-5215
Si 160-1159 160-1158
ZnSe 160-1113 160-1112
Notes: Above windows are 32 x 3 mm disks. For window compatibility please consultthe Materials Properties information on page 113 of this catalog. For additional window selections please see page 104.
Demountable Liquid Cell Spacers (Optional)PAT H L E N G T H (MM ) PA R T NUMB E R
0.015 162-1210
0.025 162-1220
0.050 162-1230
0.100 162-1240
0.200 162-1250
0.500 162-1260
1.000 162-1270
Assortment 162-1290
Notes: Spacer pathlength packages above include 12 each of the spacers. Theassortment package includes 2 each of the different pathlengths.
Demountable Liquid Cell Replacement PartsPA R T NUMB E R D E S C R I P T I O N
162-1104 Demountable Liquid Cell Needle Plate
162-1300 Teflon Stoppers for Needle Plate (12 each)
162-1310 Teflon Gaskets (12 each)
162-1320 Teflon O-Rings (12 each)
161-0520 Glass Syringe, 1 mL
161-0521 Glass Syringe, 2 mL
161-0522 Glass Syringe, 5 mL
Notes: For other options for the Demountable Liquid Cell, please contact PIKETechnologies.
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 87
Super-Sealed Liquid Cells – For Precision, Fixed Pathlength Liquid Sampling
The PIKE Technologies Super-Sealed Liquid Cells are ideal forquantitative analysis of liquid samples, especially where precise,reproducible pathlength is required.
The PIKE Technologies Super-Sealed Liquid Cells are designedto be leak-proof for long-lasting sampling and cost efficiency. TheSuper-Sealed Liquid Cells are amalgamated, further sealed withepoxy, and held firmly within the standard 2" x 3" slide mount cardcompatible with all FTIR spectrometers. The PIKE TechnologiesSuper-Sealed Liquid Cells include Luer-Lok fittings for easy syringefilling of the sample. The clear aperture of the assembled cell is 13 mm.
The PIKE Technologies Super-Sealed Cells are available in awide variety of window materials and sampling pathlengths.
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
88
ORDER I NG IN FORMAT I ON
Super-Sealed Liquid Cells – Window Options (select 1 or more)
FEATURES OF THE SUPER-SEALED LIQUID CELL
• Permanently mounted cell with fixed pathlength to provide maximum reproducibility of sample absorbance
• Flexible window selection for optimizing spectral range and sample compatibility
• Full range of cell pathlengths for optimized quantitative measurements
• Compatible with all FTIR spectrometers
Path (mm) 0.015 0.025 0.05 0.10 0.15 0.20 0.50 1.0 5.0 10.0
Volume (mL) 0.005 0.009 0.018 0.036 0.054 0.072 0.18 0.36 1.80 3.60
BaF2 162-1640 162-1641 162-1642 162-1643 162-1649 162-1644 162-1645 162-1646 162-1647 162-1648
CaF2 162-1630 162-1631 162-1632 162-1634 162-1635 162-1636 162-1633 162-1637 162-1638 162-1639
CsI 162-1680 162-1681 162-1682 162-1683 162-1689 162-1684 162-1685 162-1686 162-1687 162-1688
KBr 162-1620 162-1621 162-1622 162-1623 162-1624 162-1625 162-1626 162-1627 162-1628 162-1629
KRS-5 162-1660 162-1661 162-1662 162-1663 162-1669 162-1664 162-1665 162-1666 162-1667 162-1668
NaCl 162-1610 162-1611 162-1612 162-1613 162-1614 162-1615 162-1616 162-1617 162-1618 162-1619
SiO2 162-1609 162-1601 162-1602 162-1603 162-1609 162-1604 162-1605 162-1606 162-1607 162-1608
ZnSe 162-1650 162-1651 162-1652 162-1653 162-1659 162-1654 162-1655 162-1656 162-1657 162-1658
ZnS 162-1670 162-1671 162-1672 162-1673 162-1679 162-1674 162-1675 162-1676 162-1677 162-1678
Notes: All PIKE Technologies Super-Sealed Cells include Teflon stoppers. Please select 2 syringes (below) for filling the Super- Sealed Cell.
Super-Sealed Liquid Cell Replacement PartsPA R T NUMB E R D E S C R I P T I O N
162-1300 Teflon Stoppers (12 each)
161-0520 Glass Syringe, 1 mL
161-0521 Glass Syringe, 2 mL
161-0522 Glass Syringe, 5 mL
Notes: For other options please contact PIKE Technologies.
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 88
The PIKE Technologies Long-Path Quartz Liquid Cells are ideal forthe quantitative analysis of hydrocarbons in water and soil samplesor for the analysis of additive content in polymers after extraction.Sample extracts are easily transferred to the quartz cells forinfrared analysis. Pathlengths ranging from 10 mm to 100 mmare available for optimization of the sample absorbance. The cells are manufactured of special grade IR quartz which is fullytransparent in the hydrocarbon absorbance region. The quartzcells are compatible with organic and aqueous solvents and aresuitable for use with new D7066-04 ASTM method. A 2" x 3" slidemount holder is available for the cells.
89
TRANSMISSION
SAMPLING– A
UTOMATED
ANDMANUALTECHNOLOGIES
Spectrum of 10 mm Long-Path Quartz Cell
ORDER I NG IN FORMAT I ON
Long-Path Quartz Liquid CellsPA R T NUMB E R D E S C R I P T I O N
162-1801 Long-Path Quartz Cell, 10 mm
162-1802 Long-Path Quartz Cell, 20 mm
162-1805 Long-Path Quartz Cell, 50 mm
162-1810 Long-Path Quartz Cell, 100 mm
Notes: Cells include Teflon stoppers. Select slide sample holder below.
Long-Path Quartz Liquid Cell Parts and Sampling OptionsPA R T NUMB E R D E S C R I P T I O N
161-2530 Slide Sample Holder, Quartz Cell, 10–20 mm
161-2540 Slide Sample Holder, Quartz Cell, 50 mm
161-2550 Slide Sample Holder, Quartz Cell, 100 mm
Notes: Please contact PIKE Technologies for replacement Teflon stoppers and itemsnot described on this list.
Long-Path Quartz Liquid Cells – For Analysis of Hydrocarbon Content and Related Measurements
F E ATUR E S O F THE LONG -PATH QUART ZL I QU I D C E L L S
• For the analysis of hydrocarbon content of water, soil, andother environmental samples
• For analysis of polymer additives after extraction• Highest quality quartz cells for clear infrared spectral transmission and optimized result
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 89
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
90
The PIKE Technologies mid-IR Falcon accessory is recommendedfor qualitative and quantitative analysis of liquids where it is necessary to control the temperature of the sample. Temperaturerange of the accessory is 5 °C to 130 °C with +/- 0.5% accuracy.Heating and cooling is controlled by a built-in Peltier device providing for reproducible ramping and for reaching target temperatures quickly and reliably. The system is driven by aDigital Temperature Controller – directly, or via PC.
A wide variety of window types and spacer pathlengths areavailable for this product. Windows offered cover mid-IR, NIR, andfar-IR spectral regions and sample compositions from organic toaqueous. A complete heatable transmission cell set-up for usewith the mid-IR Falcon accessory consists of two 32 mm x 3 mmsize windows (drilled and undrilled), an assorted spacer set, theneedle plate with Luer-Lok fittings, two gaskets and a proprietarycell mount.
The full Falcon configuration requires the accessory base withcell holder, user selected windows, and one of the available temperature controllers. The Falcon accessory is compatible withmost brands of FTIR spectrometers.
FEATURES OF THE FALCON MID-IR ACCESSORY
• Peltier temperature control from 5 °C to 130 °C• Wide selection of windows for optimizing spectral range andsample compatibility
• Flexible pathlength to control sample absorbance• Demountable cell design for optimal cleaning of difficult samples
• Available for most FTIR spectrometers
ORDER I NG IN FORMAT I ON
Falcon Mid-IR Transmission AccessoryPA R T NUMB E R D E S C R I P T I O N
111-40XX Mid-IR Falcon Base with Cell HolderIncludes: Temperature controlled base, demountable cell, gaskets, and one complete set of spacers. Select windowsand the Digital Temperature Controller from the tables on the next page for complete system.
Notes: Please insert XX code found on the fold-out on the last page of this catalog.Please select 2 syringes (next page) for filling the demountable liquid.
Temperature ControllersPA R T NUMB E R D E S C R I P T I O N
076-1230 Digital Temperature Control Module for Falcon Accessory
076-1430 Digital Temperature Control Module, PC Control for Falcon Accessory
Notes: Digital Temperature Control Module is required to control temperature viaPC and includes PIKE TempPRO software.
Liquid RecirculatorPA R T NUMB E R D E S C R I P T I O N
170-1000 Liquid Recirculator
Falcon Mid-IR Transmission Accessory – For Precise Temperature Control of Demountable Liquid Cells
FALCON MID- IR TRANSMISS ION ACCESSORY SPEC IF ICAT IONS
Temperature Control Peltier (cooling and heating)
Temperature Range 5 °C to 130 °C
Accuracy +/- 0.5%
Sensor Type 3 wire Pt RTD (low drift, high stability)
Temperature Controllers
Digital +/- 0.5% of set point
Digital PC +/- 0.5% of set point, graphical setup, upto 10 ramps, USB interface
Input Voltage 90–264 V, auto setting, external power supply
Output Voltage 16 VDC/150 W max.
Dimensions (W x D x H) 89 x 121 x 83 mm(without FTIR baseplate and mount)
Notes: Peltier device must be water cooled for proper operation – this is achievedby running cold tap water through the water jacket integrated into the accessoryshell, or by the use of an external liquid circulator.
PIKE TempPRO Software for kinetic experiments
LiquidRecirculator
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 90
91
TRANSMISSION
SAMPLING– A
UTOMATED
ANDMANUALTECHNOLOGIES
Demountable Liquid Cell Windows (must select minimum of 1 Plain and 1 Drilled)
PA R T NUMB E R
D E S C R I P T I O N P L A I N DR I L L E D
BaF2 160-1147 160-1146
CaF2 160-1143 160-1142
Ge 160-1137 160-1136
KBr 160-1132 160-1131
KRS-5 160-1126 160-1125
NaCl 160-1122 160-1121
Si 160-1159 160-1158
ZnSe 160-1113 160-1112
Notes: Above windows are 32 x 3 mm disks. For window compatibility please consult the Materials Properties information on page 113 of this catalog. For additional window selections please see page 104 of this catalog.
Demountable Liquid Cell Spacers (Optional)DE S C R I P T I O N PA R T NUMB E R
0.015 mm 162-1210
0.025 mm 162-1220
0.050 mm 162-1230
0.100 mm 162-1240
0.200 mm 162-1250
0.500 mm 162-1260
1.000 mm 162-1270
Assortment 162-1290
Notes: Spacer pathlength packages above include 12 spacers. The assortment packageincludes 2 each of the different pathlengths.
Demountable Liquid Cell Replacement PartsPA R T NUMB E R D E S C R I P T I O N
162-1600 Demountable Liquid Cell for the mid-IR Falcon Accessory
162-1104 Demountable Liquid Cell Needle Plate
162-1300 Teflon Stoppers for Needle Plate (12 ea.)
162-1311 Viton Gasket, 32 mm (12 ea.)
161-0520 Glass Syringe, 1 mL
161-0521 Glass Syringe, 2 mL
161-0522 Glass Syringe, 5 mL
Notes: For other options for the Demountable Liquid Cell, please contact PIKE Technologies.
ORDER I NG IN FORMAT I ON
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 91
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
92
Falcon NIR Transmission Accessory – Quantitative and QualitativeAnalysis of Liquids under Precise Temperature Control
The PIKE Technologies NIR Transmission Accessory is an excellentchoice for quantitative and qualitative analysis of liquid samplesin the NIR spectral region. Temperature range of the accessory is5 °C to 130 °C with +/- 0.5% accuracy. Heating and cooling is controlled by a built-in Peltier device. The Peltier element providesfor reproducible ramping and for reaching target temperaturesquickly and reliably. The system is driven by a Digital TemperatureController – directly, or via PC.
Individual sample holders are designed to accommodatestandard 5 mm, 8 mm and 12 mm glass vials and 1 cm cuvettes.Sample Holders are pin positioned to ensure maximum reproducibility.
The complete NIR Falcon configuration requires the accessorybase, cell holder, and one of the available temperature controllers.The Falcon accessory is compatible with most brands of FTIRspectrometers.
F E ATUR E S O F THE FA L CON N IR A C C E S S ORY
• Fast, easy quantitative and qualitative analysis of samplesunder precise Peltier temperature control
• Choice of cuvette and vial adapters • Compatible with disposable 5 mm vials• Excellent thermal accuracy and precision • Available for most FTIR spectrometers
ORDER I NG IN FORMAT I ON
Heated NIR Transmission Accessory PA R T NUMB E R D E S C R I P T I O N
110-60XX NIR Falcon Base Includes: Temperature controlled base. Digital Temperature Controller and sample holder need to be selected from the tables below for complete system.
Notes: Please insert XX code found on the fold-out on the last page of this catalog.
Temperature ControllersPA R T NUMB E R D E S C R I P T I O N
076-1230 Digital Temperature Control Module
076-1430 Digital Temperature Control Module PC Control
Notes: Digital Temperature Control Module is required to control temperature viaPC and includes PIKE TempPRO software.
Sample Holders (must select one)PA R T NUMB E R D E S C R I P T I O N
111-3610 5 mm Vial Holder
111-3620 8 mm Vial Holder
111-3630 12 mm Vial Holder
111-3640 1 cm Cuvette Holder
Falcon NIR Accessory OptionsPA R T NUMB E R D E S C R I P T I O N
162-0205 5 mm Disposable Glass Vials, 6 mm x 50 mm (200/pk)
162-0208 8 mm Glass Vials (200/pk)
162-0212 12 mm Glass Vials (200/pk)
162-0255 Falcon 1 cm Quartz Cuvette
Notes: Please see more cuvette options on page 128.
Liquid RecirculatorPA R T NUMB E R D E S C R I P T I O N
170-1000 Liquid Recirculator
NIR transmission spectra of cooking oils in 8 mm glass vials measuredat 32 °C with the Falcon NIR Transmission Accessory
FALCON NIR TRANSMISS ION ACCESSORY SPEC IF ICAT IONS
Temperature Control Peltier (cooling and heating)
Temperature Range 5 °C to 130 °C
Accuracy +/- 0.5%
Sensor Type 3 wire Pt RTD (low drift, high stability)
Temperature Controllers
Digital +/- 0.5% of set point
Digital PC +/- 0.5% of set point, graphical setup, upto 10 ramps, USB interface
Input Voltage 90–264 V, auto setting, external power supply
Output Voltage 16 VDC/150 W max.
Dimensions (W x D x H) 89 x 121 x 83 mm (without FTIR baseplate and mount)
Notes: Peltier device must be water cooled for proper operation – this is achievedby running cold tap water through the water jacket integrated into the accessoryshell, or by the use of an external liquid circulator.
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 92
93
TRANSMISSION
SAMPLING– A
UTOMATED
ANDMANUALTECHNOLOGIES
Cryostat190 – Ultralow Temperature Accessory for Liquid andSolid Transmission Sampling
The Cryostat190 is a temperature controlled transmission accessoryfor the spectroscopic analysis of liquids and solids. Using a liquidnitrogen cryostat in combination with resistive heating the accessory’s temperature range is -190 to 150 °C.
The temperature control system uses a mass flow controllerto precisely meter the liquid nitrogen flow to maintaining steadysub ambient temperatures or to control temperature rampingwith accuracy. The 10 L Dewar provides cooling up to 10 hours,which is convenient for extended time studies and experimentsthat require long-term signal averaging.
Spectroscopic measurements at low temperatures may beperformed to refine the absorbance bands, which are generallysharper and narrower, to reduce sample degradation, and toinvestigate unstable intermediates.
F E ATUR E S O F THE CRYO S TAT190
• Temperature range is -190 °C to 150 °C• Liquid and solids holders• Cryostat cooling system with 10 L Dewar• Fits most spectrometers
ORDER I NG IN FORMAT I ON
Cryostat190 PA R T NUMB E R D E S C R I P T I O N
162-43XX Cryostat190 Includes: Cryostat, 10 L liquid nitrogen Dewar, diaphragm pump for flow of the liquid nitrogen, temperature controller with mass flow controller
Sample Holders (must select one)PA R T NUMB E R D E S C R I P T I O N
162-4301 Cryostat190 Liquid Transmission holder
162-4302 Cryostat190 Solid Transmission holder
Windows for Cryostat190 (must select two)PA R T NUMB E R D E S C R I P T I O N
160-1132 KBr window, 32 x 3 mm
160-1126 KRS-5 window, 32 x 3 mm
160-5216 Polyethylene window, 32 x 3 mm
Windows for Cryostat190 Liquid Holder (must select two)PA R T NUMB E R D E S C R I P T I O N
160-1133 KBr window, 25 x 4 mm
160-1114 ZnSe window, 25 x 4 mm
160-1312 KRS-5 window, 25 x 4 mm
160-5214 Polyethylene, 25 x 4 mm
Spacers for Cryostat190 Liquid Holder (optional)PA R T NUMB E R PAT H L E N G T H
162-1110 0.015 mm
162-1120 0.025 mm
162-1130 0.050 mm
162-1140 0.100 mm
162-1150 0.200 mm
162-1160 0.500 mm
162-1170 1.000 mm
162-1190 Assortment
Options PA R T NUMB E R D E S C R I P T I O N
162-4303 Rotary pump for vacuum insulation
162-4304 O-Ring for Liquid Cell (quantity 2)
CRYOSTAT190 SPEC IF ICAT IONS
Dimensions (W x D x H) 130 x 130 x 287 mm (excludes baseplate and fittings)
Weight 3 kgAccessory Body Stainless steelClear Aperture 20 mmCooling Method Liquid nitrogenCooling Hold Time 10 hoursTemperature Accuracy +/- 1 °C (-190 °C to 150 °C)
+/- 0.5 °C (-180 °C to 150 °C)Temperature Sensor Type-K thermocoupleOperational Conditions
Temperature Range 15–35 °CHumidity Range Below 90% RHPressure Range Ambient
Liquid nitrogen cooled system and temperature control module
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 93
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
94
Heated Solid Transmission Accessory –Measurements of Optical Components and Polymers
The Heated Solid Transmission Accessory is designed to analyzesolid samples at temperatures ranging from ambient to 300 °C. Itsupports a set of optional sample mounts able to hold samplesfrom 12 mm to 30 mm in diameter and up to 3 mm thick.Sample loading is simple and does not require any tools. Theaccessory is equipped with a standard 2" x 3" slide that makes iteasy to mount in all types of spectrometers.
The temperature of the Heated Solid Transmission Accessoryis regulated by a digital temperature controller. PC interfaced andfree-standing, dedicated versions are available. The accessorymust be equipped with a PIKE or third party liquid recirculator inorder to prevent overheating of the unit. The estimated heatingtime from ambient temperature to 300 °C is 30 minutes.
F E ATUR E S O F THE HEAT ED SO L I DTRAN SM I S S I ON AC C E S S ORY
• Quick sample loading and unloading• Selection of different size sample holders• Wide temperature range – from ambient to 300 °C• PC or dedicated controller temperature programming –including pre-set points and/or ramping
ORDER I NG IN FORMAT I ON
Heated Solid Transmission Accessory PA R T NUMB E R D E S C R I P T I O N
112-1000 Heated Solid Transmission Accessory
Notes: Please insert XX code found on the fold-out on the last page of this catalog.
Sample Holders (must select one or more)PA R T NUMB E R D E S C R I P T I O N
112-2010 12–15 mm Diameter Sample Holder
112-2020 16–20 mm Diameter Sample Holder
112-2030 21–25 mm Diameter Sample Holder
112-2040 26–30 mm Diameter Sample Holder
Temperature Controllers (must select one or more)PA R T NUMB E R D E S C R I P T I O N
076-1410 Temperature Controller – PC Control
076-1210 Temperature Controller
Liquid Recirculator PA R T NUMB E R D E S C R I P T I O N
170-1000 Liquid Recirculator
HEATED SOL ID TRANSMISS ION ACCESSORY SPEC IF ICAT IONS
Cell Body Aluminum
Mount 2" x 3" Slide Mount
Temperature Range Ambient to 300 °C
Cooling Requirements
Coolant Temp 6 °C to 28 °C
Coolant Pressure 0.1–2 kgf/cm2
Coolant Flow Rate 20–1000 mL/min
Temperature Controllers
Digital +/- 0.5% of set point
Digital PC +/- 0.5% of set point, graphical setup, up to 10 ramps, USB interface
Input Voltage 110/220 VAC switchable
Output Voltage 10A/24 VAC max.
Controller Dimensions 134 x 261 x 234 mm(W x D x H)
LiquidRecirculator
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 94
95
TRANSMISSION
SAMPLING– A
UTOMATED
ANDMANUALTECHNOLOGIES
The PIKE Technologies Bolt Press and Hydraulic Die are low-costtools for making KBr pellets for transmission FTIR analysis.
The press and die consist of a stainless steel barrel with twohardened and polished 13 mm rams. The barrels are equippedwith a fitting which allows evacuation of air while the pellet isformed. For the Bolt Press, the pressure is applied to the sampleby tightening the bolts against each other with standard 15/16"wrenches – included. For the Hydraulic Die the pressure isapplied to the sample by placing it in a hydraulic press – up to10,000 psi. Once a clear pellet is formed, the rams are removedand the sample is analyzed while still in the barrel (barrel is placeddirectly in the beam using the Press Holder with a standard 2" x 3" slide mount). Both accessories form a 13 mm pellet.
The PIKE Technologies Bolt Press and Hydraulic Die are bothequipped with a holder for your FTIR sample compartment.
Bolt Press & Hydraulic Die – Low-Cost Pellet Preparation
ORDER I NG IN FORMAT I ON
Pellet PressPA R T NUMB E R D E S C R I P T I O N
161-2500 Bolt Press for 13 mm pellets
161-3500 Hydraulic Die for 13 mm pellets
Notes: The Bolt Press includes evacuable barrel, 2 anvil bolts, 2 15/16" wrenches,and Bolt Press Holder. The Hydraulic Die includes evacuable barrel, 2 rams andHydraulic Die Holder. The maximum force limit 5 ton.
Pellet Press Options and Replacement PartsPA R T NUMB E R D E S C R I P T I O N
160-8010 KBr Powder, 100 g
161-5050 Agate Mortar and Pestle, 50 mm
161-2511 Wrench Set for Bolt Press (2 each)
161-2520 Bolt Press Holder
Notes: For other options for the Pellet Presses, please contact PIKE Technologies.
Hand Press – For Making Smaller Pellets
The PIKE Technologies Hand Press is an ideal solution for labora-tories that require only occasional preparation of KBr pellets andcannot justify the expense of a hydraulic press.
The Hand Press is an efficient, reliable and inexpensive toolwhich simplifies making small pellets. It consists of a long stainlesssteel barrel and movable stage controlled by a lever capable ofapplying high pressure to the KBr/powder mixture. The HandPress comes complete with three standard die sets (7, 3 and 1 mm).The pellet preparation involves loading of the powdered sampleinto the die chamber, placement of the upper anvil in the press andapplication of hand pressure to the lever (this is sufficient to provideclear, high quality KBr disks). The Die Collar with the formed pelletis removed from the press and in most cases it can be placeddirectly in the beam of the spectrometer for analysis. The HandPress is equipped with a platen position dial for adjustment ofthe force applied to the die and reproducible sample preparation.
ORDER I NG IN FORMAT I ON
Hand Press PA R T NUMB E R D E S C R I P T I O N
161-1100 Hand Press for 7 mm, 3 mm, and 1 mm pelletsIncludes: 7 mm, 3 mm, and 1 mm die sets, anvils, die collars, anvil ejectors and Dual Pellet Holder
Hand Press Options and Replacement PartsPA R T NUMB E R D E S C R I P T I O N
161-5700 Dual Pellet Holder for 7 mm, 3 mm, and 1 mm pellets
161-1018 Single Pellet Holder for 7 mm pellets
160-8010 KBr Powder, 100 g
161-5050 Agate Mortar and Pestle, 50 mm
161-1027 Hand Press Body
161-1028 1 mm die set
161-1024 3 mm die set
161-1010 7 mm die set
Notes: For other options for the Hand Press, please contact PIKE Technologies.
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 95
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
96
Evacuable Pellet Press – For Preparation of High Quality Pellets
The PIKE Technologies Evacuable Pellet Press is the preferredaccessory for making pellets for FTIR analysis. Preparation of KBr pellets with a 13 mm die and a hydraulic press is the mostpopular method used for generation of samples for transmissionmeasurements. It is also required by a number of standardizedprocedures, including some USLP and ASTM methods. The advantagesof this approach include the generation of high quality pellets,reproducibility, and the ability to deal with relatively difficult samples, thanks to a wide range of pressures available. The PIKEEvacuable KBr Die Kit features the following components: a stainlesssteel base with vacuum outlet, the main die block with a 13 mmcylinder, two anvils and a plunger. All components are made ofhardened stainless steel and surfaces that come in contact withthe sample are highly polished. Two O-rings are used to seal thebase/die assembly and the plunger.
Pellet preparation involves placement of the anvil in the diechamber and covering it up with the pre-measured amount ofKBr/sample mix.
The sample is covered with the second anvil and theplunger is inserted into thechamber. The entire assemblyis placed in a hydraulic pressand compressed (a vacuumline can be connected to thebase to remove moisture fromthe sample). For analysis, theformed pellet is ejected fromthe die with an extractor andmounted onto a standard 2" x 3" sample holder.
The PIKE TechnologiesEvacuable Pellet Press comescomplete with anvils and vacuum connector.
F E ATUR E S O F THE EVACUAB L E P E L L E T PR E S S
• Ideal for making high-quality KBr pellets • Apply up to 20,000 lbs (9,071 kg) of pressure• Evacuable to prevent cloudy pellets• Requires hydraulic press
Evacuable pellet press assembly layout
ORDER I NG IN FORMAT I ON
Evacuable Pellet PressPA R T NUMB E R D E S C R I P T I O N
161-1900 Evacuable Pellet Press for 13 mm pelletsIncludes: Die Block, Anvils and pellet extracting tool.
Evacuable Pellet Press Options and Replacement PartsPA R T NUMB E R D E S C R I P T I O N
160-8010 KBr Powder, 100 g
161-5050 Agate Mortar and Pestle, 50 mm
162-5300 Magnetic Film Holder – for 13 mm pellets and film samples
162-5410 Sample Card – for 13 mm pellets (10 each)
161-1908 Pellet Extracting Tool
161-1903 Anvils (2 each) for PIKE Evacuable Pellet Press
161-1906 Piston O-Rings (2 each)
161-1907 Base O-Rings (2 each)
430-1110 Vacuum Pump, 110V
430-1220 Vacuum Pump, 220V
Notes: For other options for the Evacuable Pellet Press, please contact PIKE Technologies.
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 96
97
TRANSMISSION
SAMPLING– A
UTOMATED
ANDMANUALTECHNOLOGIES
Heated Platens Accessory – For Making Thin Films of PolymericSamples for Transmission FTIR Analysis
The PIKE Heated Platens Accessory is designed to efficiently make thin films of polymer materials for infrared transmissionspectroscopy. Thin films are easily made from pellets or otherplastic sample forms.
Typically a 2–5 milligram portion of polymer is cut from thepellet or other plastic sample and placed between aluminumdisks within the heated base of the platens. The temperature ofthe platens is chosen to match the melting point of the polymermaterial. The top plate of the heated platens accessory is placedover the assembly and the unit is placed into the hydraulic press.A low force (2 tons) is generally applied to the sample in the heatedplatens accessory to make excellent films.
The PIKE Heated Platens Accessory includes insulating disksto maintain the desired temperature set point when making thinpolymer films. The insulating disks improve the quality of thinfilms, by making them more IR transmissive and thereby improving
the quality of the spectra produced from the pressed films. This isachieved by holding the temperature at the melting point of thepolymer during the film making process. Flattening the polymerbelow its melting point produces a cloudy film. Pressing the polymer film when it is above its melting point may cause polymer degradation.
The PIKE Heated Platens Accessory is compatible with the PIKECrushIR™ Hydraulic Press and other hydraulic presses (please inquire).
ORDER I NG IN FORMAT I ON
PIKE Heated Platens AccessoryPA R T NUMB E R D E S C R I P T I O N
181-2000 PIKE Heated Platens Accessory
Notes: The heated platens accessory includes spacer set, thermal insulating disks,cooling chamber, aluminum disks and magnetic film holder. Requires selection oftemperature controller below.
Temperature Controller for Heated Platens (must select) PA R T NUMB E R D E S C R I P T I O N
076-1220 Digital Temperature Control Module
Notes: The digital temperature controller is required for operation of the HeatedPlatens Accessory.
Options and Replacement Parts (optional) PA R T NUMB E R D E S C R I P T I O N
181-3000 Spacer Set (15, 25, 50, 100, 250, 500 microns)
181-3020 Aluminum Disks, 50 each
181-3010 Spacer, 15 micron
181-3011 Spacer, 25 micron
181-3012 Spacer, 50 micron
181-3013 Spacer, 100 micron
181-3014 Spacer, 250 micron
181-3015 Spacer, 500 micron
162-5300 Magnetic Film Holder – for 13 mm pellets and film samples
F E ATUR E S O F THE HEAT ED P L AT EN S AC C E S S ORY
• Fast, efficient means of making thin films for transmissionspectroscopy
• Temperature range – ambient to 300 ºC• Standard stainless steel spacer set (15, 25, 50, 100, 250 and500 microns all with 25 mm ID) included with accessory
• Integral design for easy insertion and removal of heatedplatens into the hydraulic press
• Included insulating disks to minimize heat loss during film pressing
• Standard cooling chamber included with accessory
Transmission Spectrum of Thin Film of high-density polyethylene (HDPE)produced from PIKE Heated Platens Accessory
HEATED PLATENS ACCESSORY SPEC IF ICAT IONS
Composition Stainless steel platens, mirrored surfaces
Temperature Range Ambient to 300 ºC
Temperature Stability Insulated, < 3 ºC loss at 125 ºC set pointduring press of film
Input Voltage 100–240 VAC, auto setting, external power supply
Operating Voltage 24 VDC/100 W
Sensor Type 3 wire Pt RTD (low drift, high stability)
Heating Time Ambient to 100 ºC, less than 7 minutes
Cooling Chamber Standard, conduction via liquid circulation (not supplied)
Pressing Height 3.3 cm
Spacer Thickness 15, 25, 50, 100, 250 and 500 microns
Spacer ID 25 mm
Dimensions (W x D x H) 64 x 264 x 52 mm
Maximum Force 10 US tons
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 97
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
98
CrushIR – Digital Hydraulic Press
PIKE Technologies introduces a new and advanced hydraulic pressfor making excellent quality KBr pellets for transmission FTIRanalysis. The CrushIR™ provides excellent reproducibility with itscombination of digital pressure reading and adjustable maximumpressure setting thus preventing damage to the pellet die.
The new PIKE CrushIR includes a transparent protective shieldmaking it safe for operation in a busy laboratory environment.Access for vacuum hose and other utilities is made through a portin the rear of the press.
The adjustable top screw provides flexibility for die designs ofshort and longer dimensions yielding an open stand range from2" to 4.5" (5 to 11.5 cm). The efficient sized ram stroke of 0.45"(12 mm) and adjustment screw speeds pellet making by minimizingthe time required to achieve the desired force.
The PIKE Evacuable Pellet Press and 13 mm pellet holder arean excellent addition to the PIKE CrushIR. A packaged version ofthese 3 products is available in the list below.
All mechanical components of the press are enclosed in asafety metal cabinet. The access area is protected by a high-impactpolymer shield.
ORDER I NG IN FORMAT I ON
Hydraulic Press (select one)PA R T NUMB E R D E S C R I P T I O N
181-1100 PIKE CrushIR Hydraulic Press
181-1110 PIKE CrushIR Hydraulic Press, Evacuable Pellet Press and Magnetic Holder
181-1120 PIKE CrushIR Heated Platens PackageIncludes CrushIR manual, Heated Platens and Digital Temperature Control Module
Notes: The PIKE CrushIR Hydraulic Press includes an integrated safety shield.Please specify voltage and country destination.
Hydraulic Press Options and Replacement Parts (optional) PA R T NUMB E R D E S C R I P T I O N
161-1900 Evacuable Pellet Press for 13 mm pellets
160-8010 KBr Powder, 100 g
161-5050 Agate Mortar and Pestle, 50 mm
162-5300 Magnetic Film Holder – for 13 mm pellets and film samples
162-5410 Sample Card – for 13 mm pellets (10 each)
430-1110 Vacuum Pump, 110V
430-1220 Vacuum Pump, 220V
F E ATUR E S O F THE P IKE C RU SH IR
• Up to 15 ton of force• Digital force readout for exceptional reproducibility• Adjustable maximum force• Small footprint • Transparent safety shield
FTIR spectrum of caffeine in KBr pellet made using the PIKE CrushIRHydraulic Press and Evacuable Pellet Press
PIKE CRUSHIR SPEC IF ICAT IONS
Metric English
Clamp Force (max) 13.6 metric ton 15 US ton
Platen Size (round) 100 mm 3.94"
Ram Stroke 12 mm 0.45"
Range Die Size 5–11.5 mm 2–4.5"
Dimensions (W x D x H) 30.5 x 24.9 x 34.3 cm 12 x 9.8 x 13.5"
Weight 31.8 kg 70 lbs
Input Voltage 90–264 V, auto setting, external power supply
Output Voltage 9 VDC/18 W
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 98
99
TRANSMISSION
SAMPLING– A
UTOMATED
ANDMANUALTECHNOLOGIES
Auto-CrushIR – Programmable Hydraulic Press
The PIKE Auto-CrushIR microprocessor controlled automatedhydraulic press, introduces an element of consistency into hydraulicpress applications such as pellet and thin film making. Pressure andcorresponding hold time are easily entered through its integratedtouch-screen control panel. Up to five pressure hold time rampsmay be programmed and performed within a run. During operationthe force measurement is shown on the bright color display. The pressure is released automatically after the prescribed time.This level of control enhances the uniformity and quality of transmission samples.
The Auto-CrushIR hydraulic press is equipped with a transparentprotective safety shield. Vacuum and other utilities can be conve-niently connected to the panel located in the back of the unit.
The adjustable screw at the top of the press provides flexibilityfor short and tall die designs, yielding an open stand range from2 to 4.5" (5 to 11.5 cm). The optimal ram stroke of 0.45" (12 mm)and easy top screw adjustment speed-up pellet making by reducingtime required to achieve the desired force.
PIKE offers several products that may accompany the Auto-CrushIRincluding a pellet press and heated platens.
ORDER I NG IN FORMAT I ON
Auto-CrushIR Automated Programmable Hydraulic Press (select one)PA R T NUMB E R D E S C R I P T I O N
181-1300 PIKE Auto-CrushIR Hydraulic Press (110V)
181-1302 PIKE Auto-CrushIR Hydraulic Press (220V)
181-1310 PIKE Auto-CrushIR, with Evacuable Pellet Press, and Magnetic Holder (110V)
181-1312 PIKE Auto-CrushIR, with Evacuable Pellet Press, and Magnetic Holder (220V)
Hydraulic Press Options and Replacement Parts (optional) PA R T NUMB E R D E S C R I P T I O N
161-1900 Evacuable Pellet Press for 13 mm pellets
160-8010 KBr Powder, 100 g
161-5050 Agate Mortar and Pestle, 50 mm
162-5300 Magnetic Film Holder – for 13 mm pellets and film samples
162-5410 Sample Card – for 13 mm pellets (10 each)
181-2000 Heated Platen Accessory including 15, 25, 50, 100, 250, and 500 micron spacers
F E ATUR E S O F THE P IKE AU TO - CRU SH IR
• Variable force from 1 to 15 US tons• Microprocessor controlled, consistent and reproducible forceapplication for quality pellet making
• Easy to use touch-screen programming• Small footprint• Transparent safety shield
FTIR Spectrum of cocaine in KBr pellet made with PIKE Auto CrushIRProgrammable Hydraulic Press and Evacuable Pellet Press
PIKE AUTO-CRUSHIR SPEC IF ICAT IONS
Metric English
Clamp Force (max) 13.6 ton 15 US ton
Platen Size (round) 100 mm 3.94"
Ram Stroke 12 mm 0.45"
Range Die Size 5–11.5 mm 2–4.5"
Dimensions (W x D x H) 35.6 x 29.2 x 34.3 cm 14.0 x 11.5 x 13.5”
Weight 40.8 kg 90 lbs
Voltage 110 or 220 V, 110 or 220 V, 50–60 Hz 50–60 Hz
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 99
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
100
ShakIR and Super ShakIR –For Optimized Sample Grinding
ShakIR accessories provide a fast and simple method of mixingand grinding samples for diffuse reflectance sampling and inpreparation for making KBr pellets. A small amount of sampleand the IR transparent diluent (typically KBr) are simply scoopedinto a vial with mixing ball. The accessory thoroughly mixes andpulverizes the sample within seconds.
The standard ShakIR uses reciprocating motion of the vialholder that follows a “figure 8” path. The vial is swung through a5 degree arc at high RPMs, causing the ball to strike the end ofthe vial, which is sufficient to grind most materials into a powder.
The accessory provides electronic control for precise andreproducible setting of grinding time up to 95 seconds. The protective shield provides security to grinder operation. TheShakIR construction and weight offer long-term, reliable operation and minimized vibration and noise. The ShakIR features a small footprint. The base is 14.4 cm x 17.2 cm with aheight of 27.3 cm.
The Super ShakIR also uses “figure 8” reciprocating motionfor sample grinding, plus it offers more control over grindingspeed and time intervals – specifically, 6 RPM levels, from 2500 to4600 are available and samples can be ground from 5 to 60 seconds.This provides a wide range of settings for bringing even very difficult samples to fine powder consistency quickly.
The Super ShakIR features a heavy duty metal body with achemically resistant stainless steel grinding chamber. The unitoperates quietly, regardless of RPM settings. The grinding chamberis protected by the door with a viewing window. For safety, theaccessory will not operate until the door is fully closed. The SuperShakIR footprint is 17.5 cm x 28 cm and its height is 16 cm.
F E ATUR E S O F THE SHAK IR S AMP L E GR I ND ER S
• Produce finely powdered mix of sample and diluent – ideal for clear pellets and excellent diffuse reflectance spectra
• Minimize exposure of sample to atmospheric moisture – a chief cause of cloudy pellets
• Options for grinding ordinary and difficult samples• Quiet operation and built-in safety features
ORDER I NG IN FORMAT I ON
ShakIRPA R T NUMB E R D E S C R I P T I O N
161-1070 ShakIR, Heavy Duty Sample Grinder, 110/220VIncludes mount for 1" vials
ShakIR Vials (required)PA R T NUMB E R D E S C R I P T I O N
161-1035 Stainless Steel Vial with Ball, 1" long x 0.5"
Options and Replacement Parts for ShakIRPA R T NUMB E R D E S C R I P T I O N
161-1037 Spare Stainless Steel Ball
160-8010 KBr Powder, 100 g
Super ShakIRPA R T NUMB E R D E S C R I P T I O N
161-1080 Super ShakIR, Sample Grinder, 110/220VIncludes mount for 1.7" vials with two end-cups, stainless steel vial, 50 stainless steel balls, bullet-shaped bead
Options and Replacement Parts for Super ShakIRPA R T NUMB E R D E S C R I P T I O N
161-1038 Bullet-Shaped Bead
161-1039 Stainless Steel Vial, 1.7" long
161-1041 Stainless Steel Ball Assortment (50)
160-8010 KBr Powder, 100 g
Standard ShakIR
Super ShakIR
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 100
Sample Preparation Accessories – For Solid Material Analysis (powders, mull agents, grinding tools and more)
Preparation of samples for FTIR analysis by diffuse reflection ortransmission analysis requires a number of tools and accessoriesfor convenient and high quality results. PIKE Technologies hasassembled these tools to make your FTIR sampling easier.
IR transparent powders and chunks, manual sample grindingtools with a complete selection of Agate Mortar and Pestle selectionand mulling agents are in stock and ready for immediate delivery.
101
TRANSMISSION
SAMPLING– A
UTOMATED
ANDMANUALTECHNOLOGIES
FEATURES OF SAMPLE PREPARATION ACCESSORIES
• Accessories for analysis of solids by transmission and diffuse reflectance
• Materials for pellets and mulls
ORDER I NG IN FORMAT I ON
IR Transparent PowdersPA R T NUMB E R D E S C R I P T I O N
160-8010 KBr Powder, 100 g
IR Transparent ChunksPA R T NUMB E R D E S C R I P T I O N
160-8015 KBr Chunks, 100 g
Agate Mortar and PestlesPA R T NUMB E R D E S C R I P T I O N
161-5035 35 mm Agate Mortar and Pestle
161-5040 40 mm Agate Mortar and Pestle
161-5050 50 mm Agate Mortar and Pestle
161-5065 65 mm Agate Mortar and Pestle
161-5095 95 mm Agate Mortar and Pestle
161-5100 100 mm Agate Mortar and Pestle
Notes: The 50 mm Agate Mortar and Pestle is our most popular size and recommended for most applications.
Solids and Mulls SpatulasPA R T NUMB E R D E S C R I P T I O N
042-3035 Spatula – Spoon Style
042-3050 Spatula – Flat Style
Mulling AgentsPA R T NUMB E R D E S C R I P T I O N
161-0500 Nujol
161-0510 Fluorolube
Notes: For other options for Sample Preparation Tools, please contact PIKETechnologies.
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 101
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
102
Sample Holders – For Transmission FTIR Analysis of Pellets and Films
All PIKE Technologies transmission holders are constructed ofhigh quality materials and feature a 2" x 3" standard slide mountcompatible with all FTIR spectrometers.
The Universal Sample Holders feature a spring-loaded mechanism which conveniently keeps in place films, salt plates,KBr pellets and other materials. The clear aperture of the holderare 20 mm and 10 mm. This universal holder offers great samplemounting flexibility.
Heavy-Duty Magnetic Film Holder is designed to hold thickpolymer materials and other transmission samples. The holderfeatures a large size magnet and steel plate with a 20 mm aperture.
The Magnetic Film/Pellet Holder is used to mount KBr pellets and thin polymer films. Its components include a steel plateand flexible magnetic strip. The holder is designed to support 13 mm KBr pellets and films less than 0.5 mm thick.
The PIKE Technologies Sampling Cards are inexpensive sampleholders for analysis of films, polymers, 13 mm KBr pellets andother materials. Self-adhesive treated sides make sample preparationeasy. The cards also offer compact and convenient means of sample storage.
A Dual Pellet Holder for 1, 3 and 7 mm KBr pellets is available. The holder features semi-circular mounts with slotsaccommodating specified size pellets as made using the PIKETechnologies Hand Press.
The Single Pellet Holder for 7 mm KBr pellets is designedfor use with the PIKE Technologies Hand Press. If you just make 7 mm pellets, this version is more convenient than the DualPellet Holder.
Bolt Press and Gas Cell Holders – three different sizes areavailable. Each holder has detachable support rods for differentsized accessories. The holders can also be used for placing saltplates and other large samples.
Press-On Demountable Cell Holders are used for the analysisof smears and mulls. Available in 25 mm and 38 mm versions,both include mounting plates and pressure cups. Windows andspacers must be ordered separately.
ORDER I NG IN FORMAT I ON
PA R T NUMB E R D E S C R I P T I O N
162-5600 Universal Sample Holder, 20 mm aperture*
162-5610 Universal Sample Holder, 10 mm aperture*
162-5500 Heavy-Duty Magnetic Film Holder
162-5300 Magnetic Film Holder – for 13 mm pellets and film samples
162-5400 Film Sampling Card – 20 mm clear aperture, 10 each*
162-5410 Sample Card for 13 mm pellets (10 each)*
161-5700 Dual Pellet Holder*
161-1018 Single Pellet Holder
161-2520 Bolt Press Holder
162-2105 25 mm x 100 mm Gas Cell Holder
162-2115 25 mm x 50 mm Gas Cell Holder
162-2205 38 mm x 100 mm Gas Cell Holder
162-2215 38 mm x 50 mm Gas Cell Holder
162-3600 Press-On Demountable Cell Holders for 25 mm windows
162-3610 Press-On Demountable Cell Holders for 32 mm windows
Notes: For other options for Sample Holders, please contact PIKE Technologies. Cellholders marked “*” fit all standard 2" x 3" slide mounts, but due to their heightmay not allow for a complete sample compartment door closure on some smallerspectrometers. Please consult PIKE Technologies before placing an order.
Replacement PartsPA R T NUMB E R D E S C R I P T I O N
162-5611 25 mm O-Rings for Universal Sample Holder (6 each)
162-5612 10 mm O-Rings for Universal Sample Holder (6 each)
Universal Sample Holder Heavy-Duty Magnetic Film Holder
Magnetic Film/Pellet Holder Sampling Cards
Dual Pellet Holder Single Pellet Holder
Bolt Press and Gas Cell Holders Press-On Demountable Cell Holders
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 102
Disks, Windows and Powders – For Transmission FTIR Analysis of Solid and Liquid Samples
PIKE Technologies offer Premier Stock window and crystal materials – a carefully selected range of IR transparent materialsmost often used by IR spectroscopists. They fit PIKE accessoriesand cell holders available from other vendors. All windows, crystals and powders are made from the best quality material.The optical components are individually packaged and silica gel is included with those materials which are affected by humidity.The products highlighted in Red are in stock and available forimmediate delivery. Please refer to the next pages for full rangeof IR optical materials, windows and crystals. Note, save on priceand shipping cost by selecting 6 pack versions of popular crystals.
103
TRANSMISSION
SAMPLING– A
UTOMATED
ANDMANUALTECHNOLOGIES
PowdersPA R T NUMB E R D E S C R I P T I O N
160-8010 KBr Powder, 100 g
ChunksPA R T NUMB E R D E S C R I P T I O N
160-8015 KBr Chunks, 100 g
Disks, 13 mm Diameter
1 mm ThicknessPA R T NUMB E R D E S C R I P T I O N
160-5003 13 x 1 mm KBr
160-5004 13 x 1 mm NaCl
160-1149 13 x 1 mm BaF2
160-5001 13 x 1 mm CaF2
2 mm ThicknessPA R T NUMB E R D E S C R I P T I O N
160-1301 13 x 2 mm AMTIR
160-1218 13 x 2 mm BaF2
160-1213 13 x 2 mm CaF2
160-1198 13 x 2 mm CsI
160-1191 13 x 2 mm Ge
160-1135 13 x 2 mm KBr
160-1008 13 x 2 mm KBr (6 pack)
160-1173 13 x 2 mm KRS-5
160-1170 13 x 2 mm NaCl
160-1005 13 x 2 mm NaCl (6 pack)
160-5201 13 x 2 mm SiO2
160-5120 13 x 2 mm SiO2, low OH
160-1160 13 x 2 mm Si
160-1241 13 x 2 mm ZnS
160-1115 13 x 2 mm ZnSe
160-1001 13 x 2 mm ZnSe (6 pack)
Disks, 20 mm Diameter
2 mm ThicknessPA R T NUMB E R D E S C R I P T I O N
160-1148 20 x 2 mm BaF2
160-1144 20 x 2 mm CaF2
160-1197 20 x 2 mm CsI
160-1139 20 x 2 mm Ge
160-1134 20 x 2 mm KBr
160-1128 20 x 2 mm KRS-5
160-1169 20 x 2 mm NaCl
160-5211 20 x 2 mm Polyethylene
160-5119 20 x 2 mm SiO2
160-5121 20 x 2 mm SiO2, low OH
160-1118 20 x 2 mm Si
160-5118 20 x 2 mm ZnS
160-1304 20 x 2 mm ZnSe
Disks, 25 mm Diameter
2 mm ThicknessPA R T NUMB E R D E S C R I P T I O N
160-1201 25 x 2 mm AMTIR
160-1306 25 x 2 mm BaF2
160-1212 25 x 2 mm CaF2
160-1002 25 x 2 mm CaF2 (6 pack)
160-1308 25 x 2 mm CsI
160-1307 25 x 2 mm Ge
160-1305 25 x 2 mm KBr
160-1172 25 x 2 mm KRS-5
160-1168 25 x 2 mm NaCl
160-1004 25 x 2 mm NaCl (6 pack)
160-5213 25 x 2 mm Polyethylene
160-5086 25 x 2 mm SiO2
160-5122 25 x 2 mm SiO2, low OH
160-1117 25 x 2 mm Si
160-5084 25 x 2 mm ZnS
160-1155 25 x 2 mm ZnSe
160-1007 25 x 2 mm ZnSe (6 pack)
ORDER I NG IN FORMAT I ON
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 103
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
104
Disks, 25 mm Diameter
4 mm ThicknessPA R T NUMB E R D E S C R I P T I O N
160-1217 25 x 4 mm BaF2
160-1211 25 x 4 mm CaF2
160-1196 25 x 4 mm CsI
160-1138 25 x 4 mm Ge
160-1133 25 x 4 mm KBr
160-1009 25 x 4 mm KBr (6 pack)
160-1127 25 x 4 mm KRS-5
160-1124 25 x 4 mm NaCl
160-1012 25 x 4 mm NaCl (6 pack)
160-5214 25 x 4 mm Polyethylene
160-5089 25 x 4 mm SiO2
160-5123 25 x 4 mm SiO2, low OH
160-1116 25 x 4 mm Si
160-5087 25 x 4 mm ZnS
160-1114 25 x 4 mm ZnSe
160-1109 25 x 4 Double AR coated ZnSe windows
160-1110 25 x 4 Single AR coatedZnSe windows
5 mm ThicknessPA R T NUMB E R D E S C R I P T I O N
160-1311 25 x 5 mm BaF2
160-1210 25 x 5 mm CaF2
160-1316 25 x 5 mm CsI
160-1313 25 x 5 mm Ge
160-1189 25 x 5 mm KBr
160-1003 25 x 5 mm KBr (6 pack)
160-1312 25 x 5 mm KRS-5
160-1123 25 x 5 mm NaCl
160-1011 25 x 5 mm NaCl (6 pack)
160-5100 25 x 5 mm SiO2
160-5124 25 x 5 mm SiO2, low OH
160-5090 25 x 5 mm ZnS
160-1154 25 x 5 mm ZnSe
Disks, 32 mm Diameter
3 mm ThicknessPA R T NUMB E R D E S C R I P T I O N
160-1200 32 x 3 mm AMTIR
160-1199 32 x 3 mm AMTIR, drilled
160-1147 32 x 3 mm BaF2
160-1146 32 x 3 mm BaF2, drilled
160-1143 32 x 3 mm CaF2
160-1142 32 x 3 mm CaF2, drilled
160-1195 32 x 3 mm CsI
160-1194 32 x 3 mm CsI, drilled
160-1137 32 x 3 mm Ge
160-1136 32 x 3 mm Ge, drilled
160-1132 32 x 3 mm KBr
160-1010 32 x 3 mm KBr (6 pack)
160-1131 32 x 3 mm KBr, drilled
160-1015 32 x 3 mm KBr, drilled (6 pack)
160-1126 32 x 3 mm KRS-5
160-1125 32 x 3 mm KRS-5, drilled
160-1122 32 x 3 mm NaCl
160-1013 32 x 3 mm NaCl (6 pack)
160-1121 32 x 3 mm NaCl, drilled
160-1014 32 x 3 mm NaCl, drilled (6 pack)
160-5216 32 x 3 mm Polyethylene
160-5215 32 x 3 mm Polyethylene, drilled
160-5049 32 x 3 mm SiO2
160-5125 32 x 3 mm SiO2, low OH
160-5052 32 x 3 mm SiO2, drilled
160-5126 32 x 3 mm SiO2, drilled, low OH
160-1159 32 x 3 mm Si
160-1158 32 x 3 mm Si, drilled
160-5047 32 x 3 mm ZnS
160-5048 32 x 3 mm ZnS, drilled
160-1113 32 x 3 mm ZnSe
160-1112 32 x 3 mm ZnSe, drilled
Disks, 37.5 mm Diameter
4 mm ThicknessPA R T NUMB E R D E S C R I P T I O N
160-1286 37.5 x 4 mm ZnSe, 1-side AR coated
160-1287 37.5 x 4 mm CaF2
160-1288 37.5 x 4 mm KBr
160-1289 37.5 x 4 mm KCl
160-1290 37.5 x 4 mm NaCl
160-1291 37.5 x 4 mm ZnSe
Disks, 38 mm Diameter
3 mm ThicknessPA R T NUMB E R D E S C R I P T I O N
160-1349 38 x 3 mm BaF2
160-1350 38 x 3 mm Ge
160-5220 38 x 3 mm KBr
160-1344 38 x 3 mm KRS-5
160-5218 38 x 3 mm Polyethylene
160-1233 38 x 3 mm SiO2
160-5127 38 x 3 mm SiO2, low OH
160-1353 38 x 3 mm Si
160-1315 38 x 3 mm ZnS
160-5025 38 x 3 mm ZnSe
6 mm ThicknessPA R T NUMB E R D E S C R I P T I O N
160-1357 38 x 6 mm AMTIR
160-1322 38 x 6 mm BaF2
160-1342 38 x 6 mm CaF2
160-1326 38 x 6 mm CsI
160-1323 38 x 6 mm Ge
160-1320 38 x 6 mm KBr
160-1343 38 x 6 mm KRS-5
160-1321 38 x 6 mm NaCl
160-5219 38 x 6 mm Polyethylene
160-1355 38 x 6 mm SiO2
160-5128 38 x 6 mm SiO2, low OH
160-1324 38 x 6 mm Si
160-1329 38 x 6 mm ZnSe
ORDER I NG IN FORMAT I ON
Note: The products highlighted in Red are in stockand available for immediate delivery.
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 104
Disks, 41 mm Diameter
3 mm ThicknessPA R T NUMB E R D E S C R I P T I O N
160-1216 41 x 3 mm BaF2
160-1209 41 x 3 mm CaF2
160-1188 41 x 3 mm KBr
160-1167 41 x 3 mm NaCl
160-5217 41 x 3 mm Polyethylene
160-5157 41 x 3 mm ZnS
160-1341 41 x 3 mm ZnSe
Disks, 49 mm Diameter
3 mm ThicknessPA R T NUMB E R D E S C R I P T I O N
160-5161 49 x 3 mm ZnS
160-1153 49 x 3 mm ZnSe
6 mm ThicknessPA R T NUMB E R D E S C R I P T I O N
160-5027 49 x 6 mm BaF2
160-5206 49 x 6 mm CaF2
160-5029 49 x 6 mm CsI
160-1187 49 x 6 mm KBr
160-5205 49 x 6 mm KRS-5
160-1166 49 x 6 mm NaCl
160-5164 49 x 6 mm SiO2
160-5129 49 x 6 mm SiO2, low OH
Disks, 50 mm Diameter
3 mm ThicknessPA R T NUMB E R D E S C R I P T I O N
160-5030 50 x 3 mm BaF2
160-1208 50 x 3 mm CaF2
160-5173 50 x 3 mm CsI
160-1186 50 x 3 mm KBr
160-1171 50 x 3 mm KRS-5
160-1165 50 x 3 mm NaCl
160-5177 50 x 3 mm ZnS
160-1152 50 x 3 mm ZnSe
Windows, 29 mm x 14 mm
4 mm ThicknessPA R T NUMB E R D E S C R I P T I O N
160-1215 29 x 14 x 4 mm BaF2
160-5010 29 x 14 x 4 mm BaF2, drilled
160-1207 29 x 14 x 4 mm CaF2
160-5011 29 x 14 x 4 mm CaF2, drilled
160-5007 29 x 14 x 4 mm Ge
160-5012 29 x 14 x 4 mm Ge, drilled
160-1185 29 x 14 x 4 mm KBr
160-1184 29 x 14 x 4 mm KBr, drilled
160-5009 29 x 14 x 4 mm KRS-5
160-5014 29 x 14 x 4 mm KRS-5, drilled
160-1164 29 x 14 x 4 mm NaCl
160-1163 29 x 14 x 4 mm NaCl, drilled
Windows, 38 mm x 19 mm
2 mm ThicknessPA R T NUMB E R D E S C R I P T I O N
160-1269 38 x 19 x 2 mm AMTIR
160-1270 38 x 19 x 2 mm AMTIR, drilled
160-1157 38 x 19 x 2 mm Si
160-1156 38 x 19 x 2 mm Si, drilled
160-1275 38 x 19 x 2 mm ZnS
160-1276 38 x 19 x 2 mm ZnS, drilled
160-1151 38 x 19 x 2 mm ZnSe
160-1150 38 x 19 x 2 mm ZnSe, drilled
4 mm ThicknessPA R T NUMB E R D E S C R I P T I O N
160-1214 38 x 19 x 4 mm BaF2
160-1145 38 x 19 x 4 mm BaF2, drilled
160-1141 38 x 19 x 4 mm CaF2
160-1140 38 x 19 x 4 mm CaF2, drilled
160-1193 38 x 19 x 4 mm CsI
160-1192 38 x 19 x 4 mm CsI, drilled
160-1190 38 x 19 x 4 mm Ge
160-5032 38 x 19 x 4 mm Ge, drilled
160-1130 38 x 19 x 4 mm KBr
160-1129 38 x 19 x 4 mm KBr, drilled
160-5031 38 x 19 x 4 mm KRS-5
160-5016 38 x 19 x 4 mm KRS-5, drilled
160-1162 38 x 19 x 4 mm NaCl
160-1006 38 x 19 x 4 mm NaCl (6 pack)
160-1161 38 x 19 x 4 mm NaCl, drilled
160-1292 38 x 19 x 4 mm SiO2
160-5130 38 x 19 x 4 mm SiO2, low OH
160-1293 38 x 19 x 4 mm SiO2, drilled
160-5131 38 x 19 x 4 mm SiO2, drilled, low OH
Windows, 41 mm x 23 mm
3 mm ThicknessPA R T NUMB E R D E S C R I P T I O N
160-1277 41 x 23 x 3 mm ZnS
160-1279 41 x 23 x 3 mm ZnS, drilled
160-1111 41 x 23 x 3 mm ZnSe
160-1280 41 x 23 x 3 mm ZnSe, drilled
6 mm ThicknessPA R T NUMB E R D E S C R I P T I O N
160-5146 41 x 23 x 6 mm BaF2
160-5152 41 x 23 x 6 mm BaF2, drilled
160-5147 41 x 23 x 6 mm CaF2
160-5153 41 x 23 x 6 mm CaF2, drilled
160-1183 41 x 23 x 6 mm KBr
160-1182 41 x 23 x 6 mm KBr, drilled
160-1120 41 x 23 x 6 mm NaCl
160-1119 41 x 23 x 6 mm NaCl, drilled
Notes: For disk and window sizes other than shownhere, please contact PIKE Technologies.
105
TRANSMISSION
SAMPLING– A
UTOMATED
ANDMANUALTECHNOLOGIES
ORDER I NG IN FORMAT I ON
Note: The products highlighted in Red are in stockand available for immediate delivery.
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 105
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
106
Crystal Polishing Kit – Extending the Life of IR Transparent Windows
Scratched and fogged windows diminish the quality of transmissionFTIR spectra. Their continuous replacement can be impracticaland quite expensive. A number of standard infrared windows canbe quickly restored to perfect condition with the Pike TechnologiesCrystal Polishing Kit. The Kit includes all the necessary componentsto re-polish KBr and NaCl windows quickly and effectively.
Note: We do not recommend polishing KRS-5 windows withoutexceptional safety precautions and for this reason do not includematerials for polishing KRS-5 windows.
F E ATUR E S O F THE CRY S TA L PO L I S H I NG K I T
• Complete kit for polishing IR transparent windows• Reduces cost of transmission analysis by extending KBr and NaCl window lifetime
ORDER I NG IN FORMAT I ON
PA R T NUMB E R D E S C R I P T I O N
162-4000 Crystal Polishing KitIncludes: Wooden base, glass plates, polishing pads, brushes and Polishing Compounds
Crystal Polishing Kit Replacement PartsPA R T NUMB E R D E S C R I P T I O N
162-4010 Glass Plate
162-4011 Polishing Pads (6 each)
162-4015 Brushes (6 each)
162-4012 Grinding Compound (400 grit)
162-4013 Grinding Compound (600 grit)
162-4014 Polishing Compound
Notes: For other options for window polishing, please contact PIKE Technologies.
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 106
Short-Path Gas Cells –For Samples with Higher Vapor Phase Concentration
PIKE Technologies offers several choices for analysis of gas sampleswith component concentrations generally above 1% by weight.Our Short-Path HT Gas Cells provide high throughput by virtue oftheir greater inside diameter providing more energy at the FTIRdetector. The Short-Path HT Gas Cells also include glass stopcocksfor flow input of the gas sample and sealing.
The PIKE Technologies Short-Path EC Gas Cells are recommendedfor use with occasional gas sampling and offer an economical choicewith standard septum-styled sealing of the vapor phase sample.
Both our Short-Path HT and EC Gas Cells are available in 50 mm and 100 mm versions. The complete gas cell requires yourselection of the appropriate IR transparent windows. Both HT andEC Gas Cells are slide mount accessories, compatible with all FTIRspectrometers.
107
TRANSMISSION
SAMPLING– A
UTOMATED
ANDMANUALTECHNOLOGIES
F E ATUR E S O F THE SHORT -PATH GA S C E L L S
• Gas cells for measuring higher vapor phase concentration• High throughput and economy versions• 100 mm and 50 mm pathlength versions• Fits all FTIR spectrometers
Short-Path Gas Cell PA R T NUMB E R D E S C R I P T I O N
162-2200 Short-Path HT Gas Cell, 100 mm pathlength
162-2250 Short-Path HT Gas Cell, 50 mm pathlength
162-2100 Short-Path EC Gas Cell, 100 mm pathlength
162-2150 Short-Path EC Gas Cell, 50 mm pathlength
Notes: The Short-Path Gas Cells include the glass body, o-rings and cell holder. The HT Gas Cells require selection of 38 mm x 6 mm windows. The EC Gas Cellsrequire selection of 25 mm x 4 mm windows.
Short-Path Gas Cell Windows (must select minimum of 2)PA R T NUMB E R
D E S C R I P T I O N 3 8 X 6 MM 25 X 4 MM
BaF2 160-1322 160-1217
CaF2 160-1342 160-1211
KBr 160-1320 160-1133
NaCl 160-1321 160-1124
ZnSe 160-1329 160-1114
Notes: For window compatibility please consult the Materials Properties informationon page 113 of this catalog. For additional window selections please see page 104of this catalog.
Short-Path Gas Cell Replacement Parts PA R T NUMB E R
D E S C R I P T I O N HT G A S C E L L E C G A S C E L L
Viton O-Rings (2 each) 162-2209 162-2109
Cell Window Cap 162-2202 162-2102
Gas Cell Holder 162-2205 162-2105
Glass Body for 100 mm Cell 162-2201 162-2101
Glass Body for 50 mm Cell 162-2255 162-2155
Septum Caps (12 each) NA 162-2106
Notes: For options not shown here, please contact PIKE Technologies.
ORDER I NG IN FORMAT I ON
Short-PathHT Cell
Short-PathEC Gas Cell
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 107
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
108
Heated Gas Flow Cell – For Streaming Gas Analysis
The PIKE Technologies Heated Gas Flow Cell is recommended forhigh-performance FTIR sampling of flowing gas samples. Thebeam-conforming design of the Heated Gas Flow Cell provides for minimum cell volume (38.5 mL) and a 100 mm pathlength,compatible with most FTIR spectrometers. This beam-conformingdesign also provides maximum IR throughput with no vignette ofthe IR beam. The gas cell may be heated up to 300 °C to preventcondensation of higher molecular weight gas species. The PIKETechnologies Heated Gas Flow Cell includes standard Swagelok® fittings for connection to 1/8" tubing and its stainless steel com-position is compatible with pressurized applications up to 100 psi.
Temperature control is provided by either digital or digital PCcontrollers from PIKE Technologies. Complete specification of the Heated Gas Flow Cell requires selection of your choice of IR transparent windows – 38 mm x 6 mm.
F E ATUR E S O F THE HEAT ED GA S F LOW CE L L
• High IR throughput, minimum cell volume ideal for preservingflowing gas composition
• Temperature control to 300 °C• Your choice of IR transparent windows – user changeable• Compatible with most FTIR spectrometers
Optical geometry for PIKE Technologies Heated Gas Flow Cell
Heated Gas Flow Cell PA R T NUMB E R D E S C R I P T I O N
162-20XX Heated Gas Flow CellIncludes: Cell, High Temp O-Rings, and FTIR mounting plate
Notes: Please select the XX code for your FTIR – found on the fold out on the lastpage of this catalog.
Temperature Controllers (must select one)PA R T NUMB E R D E S C R I P T I O N
076-1410 Digital Temperature Control Module, PC Control
076-1210 Digital Temperature Control Module
Notes: Digital Temperature Control Module, PC Control includes PIKE TempPROsoftware.
IR Transparent Windows for Heated Gas Flow Cell (select minimum of 2)DE S C R I P T I O N 3 8 X 6 MM PA R T NUMB E R
BaF2 160-1322
KBr 160-1320
KRS-5 160-1343
ZnSe 160-1329
Notes: For window compatibility please consult the Materials Properties informationon page 113 of this catalog. For additional window selections please see page 104 ofthis catalog.
Heated Gas Flow Cell Replacement Parts and OptionsPA R T NUMB E R D E S C R I P T I O N
162-2009 Viton O-Rings, (2 each), max temp. 200 ºC
162-2309 High Temperature O-Rings, (1 each), max temp. 325 ºC
162-2001 High Temperature Purge Tubes
Notes: For other options for the Heated Gas Flow Cell, please contact PIKE Technologies.Gas Cell requires 4 O-Rings.
ORDER I NG IN FORMAT I ON
HEATED GAS FLOW CELL SPEC IF ICAT IONS
Temperature Range Ambient to 300 °C
Accuracy +/- 0.5%
Voltage 24 VAC
Sensor Type 3 wire Pt RTD (low drift, high stability)
Controllers
Input Voltage 110/220 V, switchable
Output Voltage 10 A/24 VAC
Dimensions (W x D x H) 91 x 140 x 121 mm (excludes baseplate mount)
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 108
Long-Path Gas Cells – For Measurement of Low Concentration Vapor Components
PIKE Technologies offers several Long-Path Gas Cells for analysisof trace components in gas samples – typical concentrations mayrange from the ppm to ppb levels. The Long-Path Cells feature afolded path design providing an extended pathlength within acompact dimension. The FTIR beam enters the cell through an IRtransparent window and reflects a number of times between theaccessory mirrors before exiting to the detector. The number ofreflections is determined by the optical configuration of the celland may be selected as a permanently aligned version or a user-adjustable version (variable-path cells). Typical applicationsof the long-path gas cells include air pollution studies, gas puritydeterminations, monitoring of industrial processes, exhaust gasanalysis and many others.
All Long-Path Gas Cells are manufactured by PIKE Technologies.The fixed and variable long-path gas cell assemblies have either a nickel-coated aluminum cell or a heavy-wall borosilicate glasscell. Gas cells may be operated under vacuum or pressure. Thetop of the cell is enclosed by the valve/gauge assembly with stainless steel ¼" Swagelok valves. Tube compression fittings areavailable upon request.
For optimal performance the mirrors have been diamondturned and coated with the highest quality gold for maximumreflectivity and inertness. The accessory mirrors are mounted permanently with mechanical mirror mounts to eliminate out-gassing chemicals that may occur when using cements tosecure the mirrors. Windows are easily replaceable and differentwindow materials are available.
The anodized aluminum base includes spectrometer-specifictransfer optics allowing placement of the accessory in the FTIRsample compartment. As a standard feature, the optical base isfully purgeable allowing for the elimination of atmospheric watervapor and CO2 interference in the spectrum.
The construction and main components of the variable-pathgas cells are identical with those described above, with an exceptionof the internal mirror assembly. The cell has an adjustable mirrorlocated at the top of the enclosure (position controlled with a micrometer) and one stationary mirror. Adjust-ments to the mirror position allow selection of different pathlengths supported by the cell. The variable-path gas cell has an integrated laser that enables the determinationof the pathlength by counting the number of laser reflections on the bottom mirror.
Some gas measurement applications require temperature control for higher precision or to prevent condensation of specific components. PIKE Technologies offers heated versions of our fixed- and variable-path gas cells up to 200 °C. For high temperature accuracy, the temperature sensor has been imbedded inside the gas cell as opposed to mounted on the exterior of the cell. Contact PIKE Technologies on how to upgrade an existing cell to the heated version.
Custom pathlengths and cell materials are available. Contact PIKE Technologies for special orders.
109
TRANSMISSION
SAMPLING– A
UTOMATED
ANDMANUALTECHNOLOGIES
F E ATUR E S O F THE LONG -PATH GA S C E L L S
• Long-Path gas cells for measurements of vapor species to ppb levels
• Fixed and variable pathlength versions• Heated versions available up to 200 °C• Standard fully purgeable optics• Fits most FTIR spectrometers
Long-Path Gas Cells
C-H stretch spectral region for methane gas
5 m Heated Gas Cell
Laser reflections shown onthe bottom mirror of thevariable-path gas cell
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 109
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
110
ORDER I NG IN FORMAT I ON
Long-Path Gas Cells (insert spectrometer code for XX)PA R T NUMB E R D E S C R I P T I O N
163-12XX 2.4 m Metal Gas Cell
163-15XX 5 m Metal Gas Cell
163-10XX 10 m Metal Gas Cell
163-11XX 10 m Glass Gas Cell
163-16XX 1–16v m Glass Gas Cell
163-20XX 20 m Glass Gas Cell
Notes: Metal Gas Cells are made of nickel-plated aluminum. Long-Path Gas Cellsinclude KBr window(s) as specified in the table on this page. Please select the base-plate mount for your FTIR spectrometer model. Additional window materials can beordered from the table in the next column. Please select the xx code from the fold-out on the last page of this catalog.
Heated Long-Path Gas Cells (insert spectrometer code for XX)PA R T NUMB E R D E S C R I P T I O N
163-42XX 2.4 m Heated Metal Gas Cell, 115 V
163-42XX-30 2.4 m Heated Metal Gas Cell, 230 V
163-45XX 5 m Heated Metal Gas Cell, 115 V
163-45XX-30 5 m Heated Metal Gas Cell, 230 V
163-40XX 10 m Heated Metal Gas Cell, 115 V
163-40XX-30 10 m Heated Metal Gas Cell, 230 V
163-41XX 10 m Heated Glass Gas Cell, 115 V
163-41XX-30 10 m Heated Glass Gas Cell, 230 V
163-46XX 1–16v Heated Glass Gas Cell, 115 V
163-46XX-30 1–16v Heated Glass Gas Cell, 230 V
163-43XX 20 m Heated Glass Gas Cell, 115 V
163-43XX-30 20 m Heated Glass Gas Cell, 230 V
Notes: Metal Gas Cells are made of nickel-plated aluminum. Heated Long-Path GasCells include KBr window(s) as specified in the table on this page. Please select thebaseplate mount for your FTIR spectrometer model. Additional window materialscan be ordered from the table in the next column. Heated Long-Path Gas Cellsinclude a digital temperature controller and heating jacket. Heated Long-Path GasCells may be heated to 200 °C. Please select the xx code from the fold-out on the lastpage of this catalog.
Replacement Parts for Long-Path Gas CellsPA R T NUMB E R D E S C R I P T I O N
076-1240 Heated Long-Path Gas Cell Temperature Controller, 115 V/230 V
Notes: Please call PIKE Technologies for replacement O-rings.
Replacement Windows for Long-Path Gas CellsPA R T NUMB E R
D E S C R I P T I O N 2 5 X 4 MM 37 . 5 X 4 MM
BaF2 160-1217 –
CaF2 160-1211 160-1287
KBr 160-1133 160-1288
KCl 160-1178 160-1289
KRS-5 160-1127 –
NaCl 160-1124 160-1290
ZnSe 160-1114 160-1291
ZnSe, Anti-Reflective Coating 1-Side 160-1110 160-1286
ZnSe, Anti-Reflective Coating 2-Sides 160-1109 –
HEATED LONG-PATH GAS CELLS SPEC IF ICAT IONS
Temperature Range Ambient to 200 °C
Accuracy +/- 0.2%
Voltage 115 or 230 VAC
Sensor Type RTD
Controllers
Digital +/- 0.1 °C
Input Voltage 115 or 230 V, specify
Output Voltage 115 or 230 VAC/10A, specify
Notes: Other line voltages may require an additional transformer.
LONG-PATH GAS CELLS SPEC IF ICAT IONS
2.4 m 5.0 m 10.0 m 20.0 m 1–16 m Fixed Fixed Fixed Fixed Variable
Base Path (mm) 100 157 250 500 333
Body Material Metal Metal Glass or Metal Glass Glass
Optics Coatings Gold Gold Gold Gold Gold
Window Material KBr KBr KBr KBr KBr
Window 37.5 x 4 25 x 4 25 x 4 25 x 4 25 x 4Dimension (mm)
# Window 1 2 2 2 2
Cell Volume (L) 0.1 0.5 2.2 7.2 3.5
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 110
Transmission Sampling Techniques – Theory and ApplicationsFTIR sampling by transmission is a very popular method for collection of infrared spectra. Its use is easy to explain – themethods are intuitive and do not require sophisticated samplingaccessories. In many cases, the sample can be placed directly intothe path of the infrared beam (with the help of sample holder) andscanned. Further benefits of transmission sampling techniquesinclude compatibility with automated sampling and microsamplingtechniques such as IR Microscopy.
Transmission techniques are well documented and have beensuccessfully used for many years. A large number of spectrallibraries contain transmission spectra and are often used as references for the purpose of qualitative analysis. Transmissiontechniques offer many advantages and should be used wheneverpossible, unless reliable sample preparation becomes too difficult,too time consuming or impossible. Transmission is also widelyused for quantitative applications, as significant numbers of basicmeasurements adhere to the Beer-Lambert law. The law providesa mathematical relationship between the infrared radiationabsorbed by the sample and the sample concentration:
A = a • b • c
Where: A = absorbance a = absorptivity b = pathlength c = sample concentration
The Beer-Lambert law states that absorbance is linearly proportional to sample concentration (with sample pathlengthand absorptivity constant). The actual measurements are generatedin percent transmittance (which is not a linear function of con-centration), however, they can be converted in real time toabsorbance by all modern FTIR instrumentation. As mentionedbefore, transmission measurements are intuitive and simple.However, the majority of samples are too thick to be measureddirectly and they have to be processed in some way before meaningful data can be collected. Some of the sample preparationtechniques are time consuming and can be destructive. Liquidsand pastes are generally the easiest samples to run. A large number of liquid cells and windows are available for liquid meas-urements. Solid samples (with the exception of thin films) requiresample preparation – making a pellet (typically potassium bromide –KBr) or a mull. Gas samples require a suitable gas cell with apathlength sufficient to detect the desired component.
Sample Preparation and Analysis
LiquidsMost liquids and dissolved solids are easy to measure by transmission.Viscous liquids or pastes can be simply pressed between 2 IRtransparent windows and measured by FTIR.
Thin liquids or samples in solvent may be best run by using ademountable liquid cell or a sealed cell, consisting of two windowswith a precision spacer in-between. One of the windows has twodrilled holes for the introduction and evacuation of the sample. A large number of cell options are available – these include permanently sealed cells and demountable cells with different window materials and a wide selection of spacers.
The pathlength of liquid cells can be easily measured withyour FTIR spectrometer. Just place the empty cell into the FTIRand collect its spectrum. The frequency of the sine wave spectrum(produced by back reflection within the cell) provides the pathlength using the following equation;
P = (10 • N) / (2 • ∆ cm-1)
Where:
P = pathlength of cell in mmN = number of fringes within ∆ cm-1
∆ cm-1 = wavenumber range of fringe count
It is very important to select compatible IR transparent windowsfor your liquid samples. Please refer to the chart on the last pageof this note to select your windows. If you still have questions,please call us.
111
TRANSMISSION
SAMPLING– A
UTOMATED
ANDMANUALTECHNOLOGIES
FTIR Spectrum of 1 drop of Extra Virgin Olive Oil pressed between 25 mm KBr windows and held in the IR beam using the PIKE UniversalSample Holder.
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 111
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
112
SolidsThe easiest to analyze are film and polymer samples less than200 micrometers thick (ideal thickness for the major componentof a polymer film is about 20 microns). These samples can besimply placed into a sample holder and immediately scanned.
The thickness of the polymer film can be calculated from thefringe pattern in the spectrum using the following equation;
T = (10000 • N) / (2 • n • ∆ cm-1)
Where:
T = thickness of polymer film in micronsN = number of fringes within ∆ cm-1
∆ cm-1 = wavenumber range of fringe countn = refractive index of polymer
The same procedure can be used for samples which can besliced and pressed to an appropriate thickness – especially for IRmicrosampling.
For IR microsampling, one can place a small sliced sampleinto a sample compression cell and apply pressure to hold thesample and to thin it to a useable thickness – as shown in the following spectral data.
However, the majority of solid materials must be preparedbefore their infrared spectra can be collected. In many cases sample preparation involves grinding of the sample and mixing itwith an IR transparent material such as KBr and then pressing apellet. While this method of solids analysis is time consuming, itproduces an excellent result.
Solid Sample Preparation TipsThe best method for preparation of solid samples involves mixingthe sample (about 5% by weight) with an IR transparent material(typically KBr) and pressing a pellet. The mixing is best done withthe ShakIR accessory which produces a fully mixed and pulverizedsample in about 30 seconds. The mixing can also be done with amortar and pestle – but not as well. Generation of a pellet involvespressing the prepared mixture with a hydraulic or hand press intoa hard disk. The pellet, ideally 0.5 to 1 mm thick is then placed ina transmission holder and scanned. Typically, the pellet techniqueprovides good quality spectra with a wide spectral range and nointerfering absorbance bands.
Samples which do not grind well and/or are affected by solvents and mulling agents can be analyzed with high pressuretechniques. Typical samples include fibers and paint chips. Theaccessory used for such applications utilizes two diamond anvils.Difficult samples are placed between the diamonds and crushed,compressed and flattened to the thickness necessary to obtaingood quality FTIR spectra. Diamond cells are transparent to IRradiation except in the region of 2400 cm-1 to 1700 cm-1. The highpressure diamond cells require the use of a beam condenser oran infrared microscope.
Polymer Film from Product Packaging Material – held in place with the PIKE Universal Sample Holder. Polymer is identified as AtacticPolypropylene and the film is determined to be 27.1 microns thick.
Micro Spectrum of a Layered Polymer using a PIKE µMAX IR Microscopeand Compression Cell with KBr windows.
FTIR Spectrum of Caffeine prepared as a 13 mm KBr Pellet and held inposition with the PIKE Sampling Card.
FTIR Spectrum of Methanol Vapor measured with the PIKE 100 mm gascell using 0.50 cm-1 spectral resolution.
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 112
113
TRANSMISSION
SAMPLING– A
UTOMATED
ANDMANUALTECHNOLOGIES
An alternate method for analysis of solid materials involvesmaking a mull. Mulls are sample suspensions in Nujol (refinedmineral oil) or Fluorolube (perfluorohydrocarbon). The process is based upon mixing 1 to 2 drops of the mulling agent with aground sample until a uniform paste is formed. The paste istransferred onto a KBr or other IR transparent disk, placed in the sample compartment of the spectrometer and scanned. Theadvantage of this technique is that it is a relatively quick and simple procedure; disadvantages include interference frommulling agent absorption bands. (Both Nujol and Fluorolube havecharacteristic spectral features and in most cases have to be usedas a pair in order to generate a complete mid IR spectrum. Nujolis used below 1330 cm-1, Fluorolube above 1330 cm-1).
GasesAnalysis of gas samples is a unique form of transmission samplingby FTIR as the identified sample does not need to be of purecomposition. At high spectral resolution, most gas mixtures canbe identified and quantified since absorbance bands can beselected within the spectrum, which are resolved and distinctfrom other components within the sample.
Simple demountable cells (50 mm to 100 mm) are recom-mended for samples in a 1–10% by weight concentration range.
For highly dilute samples (ppm to ppb concentrations), long-path cells are required. The long-path cell reflects the IR beamseveral times through the sample using a set of mirrors positionedon the opposite ends of the cell, producing a pathlength to 10 to30 meters – or more. It is important to select window materialscompatible with the investigated sample. Gas sampling accessoriescan be fitted with different windows to accommodate the physicaland chemical characteristics of the measured gas. Special designsfor high pressure and temperature controlled experiments arealso available.
SummaryTransmission sampling by FTIR provides an excellent means forsample identification and quantification of sample components.Most samples measured by transmission techniques require some sample preparation, however, the quality of the results and amenability to automation and microsampling offer significant advantages.
Properties of Select Infrared Transmitting Materials For Transmission SpectroscopyMaterial Comments SWL cm-1 LWL cm-1 RI Solubility g/100 g Hardness kg/mm2 MP °C pH Range
AMTIR GeAsSe glass, brittle 11000 593 2.50 0.00 170 370 1–9
BaF2 Barium Fluoride 66600 691 1.45 0.17 82 1280 5–8
CaF2 Calcium Fluoride 79500 896 1.40 0.0017 158 1360 5–8
CsI Cesium Iodide, very hygroscopic, 42000 172 1.73 44 20 621 NASomewhat Toxic
Diamond Type IIa, strong IR absorbance 30000 <2 2.40 0.00 5700 550 1–14between 2700–1800 cm-1, costly flash point
Ge Germanium, brittle, becomes 5500 432 4.00 0.00 780 936 1–14opaque at elevated temperatures
KBr Potassium Bromide, most widely 48800 345 1.52 53 6 730 NAused for mid-IR applications
KRS-5 Thallium Bromide/Thallium 17900 204 2.37 0.05 40 414 5–8Iodide, Extremely Toxic!
NaCl Sodium Chloride 52600 457 1.49 36 18 801 NA
Polyethylene For Far-IR, swells with 625 <4 1.52 0.00 110 1.5–14some organic solvents
SiO2 Silicon Dioxide 50000 2315 1.53 0.00 460 1713 1–14
Si Silicon, strong IR absorbance 8900 624, 30 3.41 0.00 1150 1420 1–12between 624–590 cm-1
ZnS Zinc Sulfide 17000 690 2.20 0.00 240 1830 5–9
ZnSe Zinc Selenide 15000 461 2.40 0.00 120 1526 5–9
Notes: The above table is meant to be a general guide – brief and concise. For more information about these materials, consult appropriate reference books and Material Safety Data Sheets (MSDS).
SWL – Shortest wavelength for transmission, 1 mm, 50% transmission
LWL – Longest wavelength for transmission, 1 mm, 50% transmission
RI – Refractive Index, at relevant wavelength
MP – Melting point
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 113
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
114
NOT E S
09_Transmission 12-13-12_09_Transmission 12/13/12 1:32 PM Page 114
Special Applications PIKE Technologies offers several FTIR accessories
specially designed for use in a dedicated sampling
environment. Our semiconductor sampling accessories
highlight our dedication to providing tools to ease
and streamline FTIR sampling technology. If you
have special sampling needs not shown in our
catalog, please contact us – we may be able to help.
MAP300™For Fully Automated Analysis of 300 mm Semiconductor Wafers
TGA/FTIR AccessoryIdentification and Qualification of Evolved Gases fromThermogravimetric Analyzer
Page 121
Semiconductor Applications FTIR Sampling Techniques Overview
Page 125
External Sample ModuleAuxiliary Sample Compartment for Added Flexibility and CustomApplications
Page 122
Photoacoustic AccessoryNon-destructive Analysis
Page 123
GC-FTIR AccessoryIdentification of ComponentsSeparated in GC Experiment
MappIR™For Fully Automated Analysis of 200 mm Semiconductor Wafers
Vertical Wafer AccessoryFor Analysis of Semiconductor Wafers
Page 116
Page 117
Page 119
Page 117
10_SpecialApp 12-12-12_10_SpecialApp 12/13/12 1:34 PM Page 115
Vertical Wafer Accessory – For Analysis of Semiconductor Wafers
PIKE Technologies offers the Vertical Wafer Accessory for analysisof semiconductor wafers. The Vertical Wafer Accessory is an in-compartment tool for transmission analysis of semiconductorwafers for Carbon, Oxygen and BPSG. The accessory accommodateswafers up to 6 inches (150 mm) in diameter. Wafers are located ina demountable ring. Dimensional tolerances conform to SEMIstandards. Delrin (hard polymer) mounting clips eliminate contactbetween the wafer and metal surfaces during the analysis. The clipmechanism facilitates convenient and repeatable wafer placement.
The wafer support ring may be rotated through 360° andtranslated laterally through a distance of over 3" (75 mm) to produce an R-theta motion covering the entire surface of thewafer. The ring may be rotated and translated manually or auto-matically under stepper motor control using PIKE TechnologiesAutoPRO software. A scale is provided for each motion, providingverification of sample position.
The automated system incorporates two precision steppermotors for rotation and translation of the plate. The motors aredriven by the Motion Control Unit connected to a PC. The operationis managed by PIKE AutoPRO software which provides full userprogrammability and an easy to learn “point-and-click” environ-ment. Polar or Cartesian (X, Y) coordinates may also be used todefine test points. The AutoPRO software allows complex testsequences to be setup, stored as methods and implemented withfull flexibility. The Motion Control Unit features a smart powersupply and operates at 85–265 VAC, 47–63 Hz.
The PIKE Technologies Vertical Wafer Accessory requires minimum 3.5" beam height FTIR spectrometers. Please contact usfor more product details.
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
116
FEATURES OF THE VERTICAL WAFER ACCESSORY
• Transmission analysis of semiconductor wafers for Carbon,Oxygen and BPSG
• Manual and/or fully-automated operation• R-theta (rotation/translation) motion control providing complete wafer analysis
• Contamination-free wafer mount • 6", 5", 4", 3" and 2" wafer sizes and custom mounts and blanks
O R D E R I N G I N F O R M AT I O N
Vertical Wafer Accessory P A R T N U M B E R D E S C R I P T I O N
073-16XX Vertical Wafer Accessory, Manual VersionIncludes mount for your FTIR
073-26XX Vertical Wafer Accessory, Automated VersionIncludes the Motion Control Unit and AutoPRO software
Notes: Please insert FTIR XX code found on the fold-out on the last page of this catalog.Requires 3.5" beam height or greater in FTIR.
Options for Vertical Wafer AccessoryP A R T N U M B E R D E S C R I P T I O N
073-3600 6" Wafer Mount, Blank
073-3660 Additional Wafer Mount
073-3650 Insert to Support 5" Wafer
073-3640 Insert to Support 4" Wafer
073-3630 Insert to Support 3" Wafer
073-3620 Insert to Support 2" Wafer
Notes: For options not described here, please contact PIKE Technologies.
10_SpecialApp 12-12-12_10_SpecialApp 12/13/12 1:34 PM Page 116
MappIR and MAP300 – For Automated Analysis of Semiconductor Wafers
PIKE Technologies offers fully automated accessories for the analysisof semiconductor wafers. Our MappIR and MAP300 accessoriesprovide for analysis of EPI, BPSG, Oxygen and Carbon in wafersizes ranging from 2 to 12 inches (50 to 300 mm).
The MappIR and MAP300 have been developed to providethe semiconductor industry with reasonably priced, automatedtools for research and quality control of silicon wafers. TheMappIR was developed for the analysis of 8 inch (200 mm) andsmaller semiconductor wafers.
The MAP300 is a larger version of this original design and it iscapable of handling the newer 12 inch (300 mm) wafer formats. Theoperation, electronics and software are identical for both systems.
The MappIR and MAP300 accessories mount in the samplecompartment of the FTIR spectrometer. Semiconductor wafers are held in place by spring-loaded Delrin retaining clips and are never in contact with the aluminum stage of the accessory. A standard size slot for a vacuum or mechanical wand is providedfor ease of wafer handling. Individual wafers are rotated and/ortranslated by stepper motors in a sequence pre-programmed bythe system operator.
To minimize interferences of water vapor and carbon dioxidewith infrared measurements, the optical path of the accessories isequipped with purging lines and can be purged with dry air ornitrogen. To eliminate exposure to atmospheric interferences, apurge box providing full enclosure of the sampling area is offeredas an option.
The accessories are controlled by AutoPRO software whichprovides a simple user interface for multiple point wafer analysis(mapping). Up to 320 points with 8 mm beam and 5 mm edgeexclusion can be measured on a 12 inch wafer. The software provides ample flexibility in setting up various experiments.
The following are advantages of the AutoPRO package:
• Graphical and intelligent user interface for setting-up mapping patterns
• Selection of wafer size, IR beam diameter, and edge exclusion
• Operator selectable or pre-defined multiple point maps
• Polar and/or Cartesian coordinates options
• Real-time display of the experiment status
• Ability to save and recall various experimental patterns
• Flexible, COM enabled interface
• KLA and CSV file importer
Data collection and processing is provided by the spectrometersoftware. A number of FTIR manufacturers offer dedicated packageswhich fully integrate the accessory with the spectrometer. If suchan option is not available, AutoPRO can be controlled by thespectrometer’s program viamacros. AutoPRO is Windowscompliant and when run sep-arately, it allows configuration,programming and control of the accessory.
The automated wafertesting systems are compatiblewith most commercial FTIRspectrometers and softwarepackages.
117
SP
EC
IA
LA
PP
LI
CA
TI
ON
S
PIKE TechnologiesMappIR Accessory
F E AT U R E S O F M A P P I R A N D M A P 3 0 0
• Complete hardware and software package for automated,multi-position measurements and mapping of semiconductor wafers
• 8 inch (200 mm) and 12 inch (300 mm) semiconductor waferhandling. Optional inserts for wafer sizes from 2 to 12 inches
• EPI, BPSG, Oxygen and Carbon determination• Specular reflectance and transmission sampling – standard• Purgeable accessory for removal of atmospheric interferences
PIKE TechnologiesMAP300 Accessory
10_SpecialApp 12-12-12_10_SpecialApp 12/13/12 1:34 PM Page 117
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
118
MappIR and MAP300 Automated Semiconductor Wafer Accessories P A R T N U M B E R D E S C R I P T I O N
016-28XX MappIR Automated Semiconductor Wafer Accessory for 8" WafersIncludes: Wafer mount, Motion Control Unit, AutoPRO software and mount for your FTIR.
017-28XX MAP300 Automated Semiconductor Wafer Accessory for 12" WafersIncludes: Wafer mount, Motion Control Unit, AutoPRO software and mount for your FTIR. Insert to support 8" wafersis also included.
Notes: Please insert FTIR XX code found on the fold-out on the last page of this catalog.
Options for the MappIR and MAP300 AccessoriesP A R T N U M B E R D E S C R I P T I O N
073-3880 Additional 8" Wafer Mount (MappIR only)
073-3800 Blank Support – for custom wafers (MappIR only)
017-3912 Additional 12" Wafer Mount (MAP300 only)
017-3980 Insert to Support 8" Wafer (MAP300 only)
073-3860 Insert to Support 6" Wafer
073-3850 Insert to Support 5" Wafer
073-3840 Insert to Support 4" Wafer
073-3830 Insert to Support 3" Wafer
073-3820 Insert to Support 2" Wafer
016-30XX Purge Box for MappIR
017-30XX Purge Box for MAP300
Notes: Purge box will not fit with all spectrometer types. For additional informa-tion or for options not described here contact PIKE Technologies.
O R D E R I N G I N F O R M AT I O N
MAP300 MappIR
12"
8"
6"
5"
4"
3"
2"
Optional Purge Box mounted on 8" MappIR accessory
10_SpecialApp 12-12-12_10_SpecialApp 12/13/12 1:34 PM Page 118
119
SP
EC
IA
LA
PP
LI
CA
TI
ON
S
TGA/FTIR Accessory – Identification and Quantification of Evolved Gases from Thermogravimetric Analyzer
The PIKE Technologies TGA/FTIR Accessory is designed to be aninterface for evolved gas analysis from a thermogravimetric analyzer(TGA) to your FTIR spectrometer. Evolved gases from the TGA passthrough a heated transfer line into the beam conforming flow cellin the FTIR sample compartment. As these evolved gases travelthrough the flow cell, FTIR spectra are collected and stored forfurther processing. Qualitative and quantitative measurementsare doable from sample masses – typically in the low milligramrange. The PIKE TGA/FTIR Accessory is compatible with most FTIRspectrometers and most TGA instruments.
During the TGA analysis sample mass is lost through a combination of volatilization and degradation of the samplematerial. The heated TGA/FTIR system maintains the vapor stateof the evolved gases throughout the FTIR analysis.
The FTIR spectrometer is set to collect spectra at 10 secondintervals during the evolved gas analysis using the kinetics software package for your FTIR. With this software you can generatereconstructions of total IR response verses time or temperature(Gram-Schmidt) or specific IR band reconstructions to isolatepoints of unique component evolutions. FTIR spectra are extractedfrom the data set and an identification is made by comparingthese unknown spectra to vapor phase spectral libraries.
F E AT U R E S O F T H E TG A / F T I R A C C E S S O R Y
• Gas cell design conforming to IR beam geometry – maximizes IR throughput
• 100 mm IR beam pathlength for maximized FTIR sensitivity• Baseplate mounted in your FTIR for flexible sampling• Temperature control settable up to 300 °C for flow cell and transfer line
• User changeable IR transparent windows to minimize cost of operation
• Heated, glass lined stainless steel transfer line for inert transfer of TGA effluent
• Purge tubes provide stable purge environment for the FTIR system
TGA/FTIR Data for Cured Rubber Sample. Upper trace is the Gram-SchmidtReconstruct of the TGA evolved gases. Lower trace is a carbonyl recon-struction and a FTIR spectrum from this data set.
IR Beam Conforming Optical Design of PIKE Technologies TGA/FTIR Accessory
10_SpecialApp 12-12-12_10_SpecialApp 12/13/12 1:34 PM Page 119
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
120
TGA/FTIR Accessory Flow CellP A R T N U M B E R D E S C R I P T I O N
162-24XX TGA/FTIR Accessory Flow Cell
Notes: Please see the FTIR instrument code sheet. TGA/FTIR Accessory includesmount for your FTIR, exhaust line and High Temperature O-Rings. Complete accessory requires selection of IR transparent windows, heated transfer line andtemperature controller.The TGA/FTIR accessory requires installation by a trainedservice representative – please consult with your FTIR manufacturer.
IR Transparent Windows for TGA/FTIR Accessory (must select 2 or more)
P A R T N U M B E R D E S C R I P T I O N
160-1320 KBr window, 38 x 6 mm
160-1329 ZnSe window, 38 x 6 mm
Notes: For window compatibility please consult our Materials Properties informationin the Transmission section.
TGA/FTIR Accessory Heated Transfer Line (must select one)P A R T N U M B E R D E S C R I P T I O N
115-0001 Heated Transfer Line for Shimadzu TGAIncludes take-off valve modifications
115-0005 Heated Transfer Line for Mettler 851 TGA
115-0006 Heated Transfer Line for Mettler 851e/LF or TGA-DSC1 TGA
115-0007 Heated Transfer Line for TA Instruments Q600 TGA
115-0008 Heated Transfer Line for TA Instruments Q5000R TGA
115-0009 Heated Transfer Line for TA Instruments Q50/Q500 TGA
115-0010 Heated Transfer Line for TA Instruments 2050 TGA
115-0011 Heated Transfer Line for Netzsch TGA
115-0012 Heated Transfer Line for PESTA6/4000 110V TGA
115-0013 Heated Transfer Line for SETARAM
115-0014 Heated Transfer Line for PESTA6/4000 220V TGA
Notes: We will need to know the make and model number of your TGA. Please consult your TGA supplier to ensure compatibility with evolved gas analysis.Please contact us about interface to other TGA instruments.
TGA/FTIR Accessory Temperature Controllers (must select one)P A R T N U M B E R D E S C R I P T I O N
076-1120 Dual Digital Temperature Control Module
076-1130 4 Zone Digital Temperature Control Module for Shimadzu TGA
Notes: These temperature controllers provide setting for the heated gas cell and theheated transfer line.
TGA/FTIR Accessory Replacement Parts and OptionsP A R T N U M B E R D E S C R I P T I O N
162-2309 High Temperature O-Rings, (1 each), max temp, 325 °C
162-2001 High Temperature Teflon Purge Tubes
Notes: 4 o-rings are required for the gas cell.
O R D E R I N G I N F O R M AT I O N
TGA/FTIR ACCESSORY SPEC IF ICAT IONS
Temperature Range Ambient to 300 °C
Accuracy +/- 0.5%
Voltage 24 VAC
Sensor Type 3 wire Pt RTD (low drift, high stability)
Controllers
Input Voltage 110/220 V, switchable
Output Voltage 10 A/24 VAC
10_SpecialApp 12-12-12_10_SpecialApp 12/13/12 1:34 PM Page 120
121
SP
EC
IA
LA
PP
LI
CA
TI
ON
S
GC-FTIR Accessory – Combining GC Separation with Identification Power of FTIR
The PIKE Technologies GC-FTIR Accessory is an interface betweenthe GC and the FTIR instruments. When fully installed, the samplepathway from the end of the GC column is diverted to a heated gascell and back to the GC detector through the use of temperaturecontrolled transfer lines. To maximize sensitivity, the light pipe isgold-coated and the accessory includes an on-board MCT detector.
Coupling gas chromatography with infrared spectroscopy provides an effective method of separating compounds as thesample moves through the GC column and identifying these compounds by spectroscopy. GC-FTIR is a preferred method foridentifying isomers, which may be incorrectly identified usingGC/MS. In addition, GC-FTIR may be used as a complementaryanalytical technique to confirm GC/MS results. Typical applica-tions of GC-FTIR include the analysis of drugs, fragrances, andother organic compounds found in mixtures.
O R D E R I N G I N F O R M AT I O N
GC-FTIR Base Accessory (must select, insert spectrometer model for XX)P A R T N U M B E R D E S C R I P T I O N
140-10XXR GC-FTIR Accessory, Right Side
140-10XXL GC-FTIR Accessory, Left Side
Notes: GC-FTIR Accessory includes optics, mounting hardware, narrow-band MCTdetector and detector electronics, heated gas cell and temperature controller. TheGC-FTIR accessory requires installation by a trained service representative; pleaseconsult with your FTIR and GC manufacturer. Please see the FTIR instrument codesheet for XX.
GC-FTIR Transfer Line (must select transfer line)P A R T N U M B E R D E S C R I P T I O N
115-0050 GC-FTIR Accessory Transfer Line
GC-FTIR Accessory Replacement Parts P A R T N U M B E R D E S C R I P T I O N
160-1135 KBr Window, 13 mm x 2 mm (single)
160-1008 KBr Window, 13 mm x 2 mm (Pack of 6)
140-2001 GC Graphite Window Gasket
140-2010 Ferrule for 0.25 mm coupling (Pack of 5)
140-2015 Ferrule for 0.32 mm coupling (Pack of 5)
140-2020 Ferrule for 0.53 mm coupling (Pack of 5)
F E AT U R E S O F T H E G C - F T I R A C C E S S O R Y
• Isomer identification• Secondary confirmation of GC/MS results• 120 mm IR beam pathlength for maximized FTIR sensitivity• Temperature control settable up to 300 °C for flow cell and transfer line
• Purgeable module
Optical geometry of the GC-FTIR Accessory
GC-FTIR ACCESSORY SPEC IF ICAT IONS
Dimensions (W x D x H) 51 x 45 x 27 cm
Weight 16 kg
FTIR Placement Right or Left Side
Beam Height Specific for FTIR
Detector Options Yes
Purge Purgeable
Light Pipe Pathlength 120 mm
Maximum Temperature 300 °C
Integrated MCT Detector
Light Pipe
IR Beam From FTIR Transfer
Line
GC-FTIR data for IBMA
10_SpecialApp 12-12-12_10_SpecialApp 12/13/12 1:34 PM Page 121
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
122
External Sample Module – Extending Sampling Efficiency
The External Sample Module (ESM) from PIKE Technologies is aversatile sampling station for FTIR spectrometers. It provides an additional sample compartment to keep the main samplecompartment of the FTIR free for routine sampling and also provides a location for a more complex sampling setup. Examplesof experiments ideally suited to using the External SampleModule include a long-path gas cell, PIKE TGA/FTIR accessory,MappIR™ and the AutoDiff™ (PIKE’s automated diffuse reflectanceaccessory). The sample compartment of the ESM is full sized, andcompatible with all PIKE Technologies accessories.
In addition to being a traditional sample compartment, theESM has a screw-hole grid for customized optical layouts withremovable inner and outer walls.
The External Sample Module is compatible with either sealedand desiccated or purged FTIR spectrometers. The PIKE ESM maybe paired with most FTIR spectrometers with an external beam.
External Sample Module (must select, insert spectrometer model for XX)P A R T N U M B E R D E S C R I P T I O N
155-10XXR External Sample Module, Right Side
155-10XXL External Sample Module, Left Side
Notes: External Sample Module includes optics, mounting hardware, electricalcabling for FTIR and purge tubing and fittings to connect to purge air supply. Please see the FTIR instrument code sheet for XX.
Detector for External Sample Module (must select one or more)P A R T N U M B E R D E S C R I P T I O N
155-2010 DLaTGS Detector for External Sample Module
155-2020 MCT Detector (mid band) for External Sample Module
Notes: Detectors for the External Sample Module may be exchanged by the customerand are pin-mounted for easy exchange without alignment. Please ask us aboutother detector options.
F E AT U R E S O F T H E
E X T E R N A L S A M P L E M O D U L E ( E S M )
• Utilizes external beam of FTIR – keeps main sample compartment free for general sampling
• Right and left side external beam versions• Full sized dimensions – for all sample compartment accessories• Choice of integrated detector• Ideal accessory for heated applications or a difficult experi-mental setup – saving time and improving reproducibility
• Customizable configuration – removable sample compartmentwalls for specific optical layouts
• Vibration isolated design – providing highest spectral quality• Compatible with most FTIR spectrometers• Requires installation by your FTIR spectrometer provider
Optical geometry for right side ESM
O R D E R I N G I N F O R M AT I O N
EXTERNAL SAMPLE MODULE S P E C I F I C AT I O N S
Dimensions (W x D x H) 615 x 490 x 205 mm
Weight 28 kg
FTIR Placement Right or Left Side
Beam Height Specific for FTIR
Sample Compartment Size (W x D x H) 190 x 265 x 155 mm
Detector Options DTGS, MCT, others inquire
Screw Hole Grid 1" OC, 1/4-20, sealed
Sample Compartment EFL 6"
Purge Purgeable
Inner, Outer Walls Removable
FTIR Compatibility Most
10_SpecialApp 12-12-12_10_SpecialApp 12/13/12 1:34 PM Page 122
123
SP
EC
IA
LA
PP
LI
CA
TI
ON
S
PA301 and PA101 – Photoacoustic Accessory for Analysis ofDifficult Samples and Depth Profiling
Photoacoustic spectroscopy (PAS) overcomes drawbacks that mayoccur with traditional spectroscopic sampling techniques due tothe physical and chemical nature of the sample. PAS is ideal forthe analysis of highly absorbing samples, layered polymers, fibers,and samples with varying surface roughness such as minerals andsoils. The technique is non-destructive. Using PA technologies,Gasera accessories offer high sensitivity, good selectivity and fastresponse time for reliable analysis of gases, liquids, and solidmaterials. A dedicated gas analyzer and a multipurpose analyzerfor solids, semi-solids, liquids, and fibers are available.
High sensitivity is achieved by using a patented cantileverpressure sensor that is over hundred times more sensitive com-pared to a membrane, which is used in conventional techniques.Gasera's patented cantilever-type pressure sensor is designed tosignificantly improve the sensitivity of photoacoustic spectroscopy.An extremely thin cantilever portion moves like a flexible doordue to the pressure variations in the surrounding gas. The move-ment of the free end of the cantilever can be about two orders ofmagnitude greater than the movement of the middle point of thetightened membrane under the same pressure variation. This isbecause the cantilever only bends and does not stretch.
Data collection may be performed in rapid-scan mode optimized at 2.5 kHz or in step-scan mode with or without phasemodulation. In rapid-scan or slow step-scan mode the thermaldiffusion depth, defined as the length to decay 37% (1/e) of theoriginal thermal wave amplitude, increases at longer wavelengths.For experiments performed in step-scan mode with phase modu-lation, the thermal diffusion depth may be linearized, eliminatingthe signal dependency on wavelength. Table 1 and 2 summarizethermal diffusion depths for rapid-scan and step-scan experimentsfor a typical polymer. For optimal performance, Helium purge gasis recommended.
PA101 is a low volume gas analyzer having an internal gasvolume of 30 mL. The absorption is measured directly by applying photoacoustic techniques. This makes the measurementfree of drift. It is the key factor for the unbeatable stability and reliability with-out frequent backgroundmeasurement. Typical low volume applications are headspace analysis, synthesisand decomposition processanalysis, and outgassing ofmaterials measurements.Typical measurement concentration for PAS of the gas phase is in the sub-ppm region.
F E AT U R E S O F T H E P H O T O A C O U S T I C A C C E S S O R Y
• Versatile and rapid analysis of solid, semi-solid, liquid, and gas samples
• Ideal sampling technique for highly absorbing samples• Requires no sample preparation, and is non-destructive• Depth probing capabilities• Patented optical microphone based on cantilever sensortechnology
• May be used in the NIR/MIR/FIR spectral regions
Heavy oil spectrum collected using the PAS301 (8 cm-1, scan time 25 s)
PA101 for gas analysis
Table 1: Thermal diffusion depth (L) in microns from PAS step scan without phase modulation and rapid scan sampling modes for a polymer with thermal diffusivity = 0.001 cm2/s.
Frequency (Hz) L, 6000 cm-1 L, 3000 cm-1 L, 1000 cm-1 L, 400 cm-1
5 92 130 224 355
10 65 92 159 251
25 41 58 100 159
2,500 4 6 10 16
Table 2: Thermal diffusion depth (L) in microns from PAS sampling in step-scanmode with phase modulation for a polymer with thermal diffusivity = 0.001 cm2/s.
Phase Modulation Frequency (Hz) L
2 126
4 89
10 56
50 25
Phase Modulation Frequency (Hz) L
200 13
400 9
700 7
900 6
PA301 PhotoacousticDetector
10_SpecialApp 12-12-12_10_SpecialApp 12/13/12 1:34 PM Page 123
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
124
O R D E R I N G I N F O R M AT I O N
Photoacoustic AccessoryP A R T N U M B E R D E S C R I P T I O N
180-11XX PA301Includes photoacoustic cell, digital signal processing unit, sampling cups and holders, carbon black reference, baseplate, KBr window and cabling
180-10XX PA101Includes photoacoustic cell for gas sampling, digital processing unit, baseplate, BaF2 window and cabling
180-2010 Gas Flow Meter
Notes: PA301 and PA101 require the gas flow meter. Please see the FTIR instrumentcode sheet for XX.
Options P A R T N U M B E R D E S C R I P T I O N
180-2011 PAS301 Carbon Black Reference
180-2012 Sample Cups, small
180-2013 Sample Cups, large
180-2014 KBr, 19 x 2 mm
180-2015 BaF2, 19 x 2 mm
180-2016 Si, 19 x 2 mm
180-2017 Quartz, 19 x 2 mm
180-2018 ZnSe, 19 x 2 mm
180-2019 CsI, 19 x 2 mm
180-2020 KBr, 14 x 2 mm
180-2021 BaF2, 14 x 2 mm
180-2022 Si, 14 x 2 mm
180-2023 Quartz, 14 x 2 mm
180-2024 ZnSe, 14 x 2 mm
180-2025 CsI, 14 x 2 mm
Notes: PA301 uses one 19 x 2 mm window. PA101 uses one 14 x 2 mm window.
PHOTOACOUST IC ACCESSORY S P E C I F I C AT I O N S
PA301
Dimensions (W x D x H) 170 x 180 x 95 mm (excludes baseplate and fittings)
Weight 3.0 kg
Operational Conditions
Temperature Range 15–35 °C
Humidity Range below 90% RH
Pressure Range Ambient
Sample Cups 10 mm ID x 9 mm H5 mm ID x 1 mm H
Purge Gas He (preferred)
PA101
Dimensions (W x D x H) 165 x 165 x 290 mm (excludes baseplate and fittings)
Weight 6.0 kg
Gas Cell Volume 30 mL
Gas Pressure 300–1500 mbar
Temperature Ambient to 50 °C
Particulate Size Less than 1 micron
Operational Conditions
Temperature Range 0–45 °C
Humidity Range Below 90% RH
Pressure Range Ambient
Power Supply Unit for PA301 and PA101
Input Voltage 100–240 VAC; 50–60 Hz
Input Power Max 30 W
10_SpecialApp 12-12-12_10_SpecialApp 12/13/12 1:34 PM Page 124
125
SP
EC
IA
LA
PP
LI
CA
TI
ON
S
Semiconductor Applications – FTIR Sampling Techniques OverviewFTIR spectroscopy has established itself as a method of choice inseveral areas of industrial manufacturing. One of them is the qualitycontrol of semiconductor wafers. Here, the FTIR spectrometersare commonly used to measure Phosphosilicate glass (PSG) andBorophosphosilicate glass (BPSG) films, epitaxial film (EPI) thicknessand interstitial oxygen and substitution carbon content.
Addition of boron and phosphorus to silicate glass duringmanufacturing improves the final product uniformity and reducesglass forming temperatures. Borophosphosilicate glass (BPSG)melts 100 degrees lower than Phosphosilicate glass (PSG) andoffers better flow characteristics. To maintain and optimize pro-duction processes, evaluation and verification of doping levels isrequired. FTIR allows simultaneous measurements of boron andphosphorus as well as the thickness of the glass in a quick andnondestructive procedure. The measurements are based on theinterpretation of transmission spectra and quantification of boron,phosphorus and Si-O bands. K-matrix or Partial Least Squares(PLS) methods are used for concentration/thickness calculations.
The epitaxial film (EPI) is a grown crystal layer having thesame crystallographic orientation as the substrate crystal wafer.The epitaxial film differs from the substrate base as it is modifiedwith various additives. Accurate, fast and precise determination ofthe EPI film thickness is important in the manufacturing processsince film thickness and uniformity play a critical role in etchingtime and device yield across the wafer surface. Specularreflectance is used in FTIR measurements of the epitaxial layerthickness. The infrared beam enters the EPI layer, reflects off thesubstrate surface and makes another pass through the film whenexiting. The film thickness calculations are based on one of thefollowing methods:
• Interference measurements – also called Constant AngleReflection Interference Spectroscopy or CARIS. This method uses the interference fringe pattern obtained in the specularreflectance experiment.
• Interferogram subtraction – based on the measurement of the primary and secondary interferogram of the sample andsubtraction of this signal from that of the reference material.
• Second Fourier Transform of spectral response data (CEPSTRUM).This method takes the difference of two spectral response curvesand performs a second Fourier transform which provides signalintensity vs. sample thickness information.
Oxygen and carbon may be introduced to the molten siliconduring the manufacturing process. These impurities can be trappedin the crystal lattice and affect final product characteristics. Forthese reasons, both need to be monitored and quantified. FTIRspectroscopy (transmission measurements) provides excellentmeans to perform this analysis. The application uses the absorptionbands of Si-C and Si-O-Si to calculate concentration levels of substitution carbon and interstitial oxygen. Beer’s law is typicallyused to determine their concentrations.
FTIR spectrum of BPSG on silicon wafer – transmission sampling mode
10_SpecialApp 12-12-12_10_SpecialApp 12/13/12 1:34 PM Page 125
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
126
N O T E S
10_SpecialApp 12-12-12_10_SpecialApp 12/13/12 1:34 PM Page 126
UV-Vis Accessories This is the most recent addition to the PIKE accessory catalog addressing the growing need formore sophisticated UV-Vis accessories. It includesresearch-style specular reflectance, polarizers, and automated sampling stages. To simplify yourshopping experience, we also include a selection ofmost used UV-Vis cuvettes and cuvette holders. It isour intention to significantly increase this UV-Visoffering in the near future – therefore, please contactus if you do not find an accessory you need, or aresearching for a customized product or solution. Inmost likelihood, we will be able to assist you withyour special requests.
UV-Vis VeeMAX™Variable Angle SpecularReflectance Accessory
Page 133
Peltier Cuvette HoldersPrecise Control of Sample Temperature
Page 134Page 135
Automated XY, R-Theta and Y-rotation Stages for UV-VisSpectrophotometers
Page 137
UV-Vis PolarizersManual and Automated Versions
Page 130
UV-Vis Spec Slide Mounted SpecularReflectance Accessories
Page 131
UV-Vis Cuvettes, Cells, Vials and Holders
Page 128
UV-Vis 85Spec™ Specular Reflectance Accessory
Page 132
11_UV-Vis 12-13-12_11_UV-Vis 12/13/12 1:35 PM Page 127
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
128
UV-Vis Cuvettes, Cells, Vials and Holders
PIKE Technologies offers a selection of most popular cuvettes, vialsand cell holders used in the field of UV-Vis spectrophotometry.The cuvettes are manufactured using a heat fusing method whichensures that they are fused into a single homogeneous unit.Cuvettes are carefully annealed to remove any residual strain for maximum cell integrity and physical strength.
The cells can be used with most solvents and acidic solutions.Hydrofluoric acid (HF) and strong bases (pH >9) will negativelyaffect the cell surfaces.
UV-VIS CUVET TES SPECIFICATIONS
Window Thickness 1.25 mm
Beam Height (Z-dimension) 8.5 mm and 11 mm
Optical Glass Spectral Range 334 to 2500 nm
Far UV Quartz Spectral Range 170 to 2700 nm
NIR Quartz Spectral Range 220 to 3800 nm
Standard Rectangular Cuvettes
PATHLENGTH VOLUME OPTICAL GLASS (334–2500 nm) FAR UV QUARTZ (170–2700 nm) NIR QUARTZ (220–3800 nm)mm mL WITH PTFE COVER P/N WITH PTFE STOPPER P/N WITH PTFE COVER P/N WITH PTFE STOPPER P/N WITH PTFE COVER P/N WITH PTFE STOPPER P/N
1 0.40 162-0220 162-0228 162-0236 162-0244 162-0252 162-0260
2 0.70 162-0221 162-0229 162-0237 162-0245 162-0253 162-0261
5 1.70 162-0222 162-0230 162-0238 162-0246 162-0254 162-0262
10 3.50 162-0223 162-0231 162-0239 162-0247 162-0255 162-0263
20 7.00 162-0224 162-0232 162-0240 162-0248 162-0256 162-0264
40 14.00 162-0225 162-0233 162-0241 162-0249 162-0257 162-0265
50 17.50 162-0226 162-0234 162-0242 162-0250 162-0258 162-0266
100 35.00 162-0227 162-0235 162-0243 162-0251 162-0259 162-0267
Semi-micro Rectangular Cuvettes – 4 mm Opening
PATHLENGTH VOLUME WITH PTFE COVER/CLEAR WITH PTFE COVER/BLACK WALLED WITH PTFE STOPPER/CLEAR WITH PTFE STOPPER/BLACK WALLEDmm mL PART NUMBER PART NUMBER PART NUMBER PART NUMBER
OPTICAL GLASS (320–2500 nm)
5 0.70 162-0268 162-0273 162-0278 162-0283
10 1.40 162-0269 162-0274 162-0279 162-0284
20 2.80 162-0270 162-0275 162-0280 162-0285
40 5.60 162-0271 162-0276 162-0281 162-0286
50 7.00 162-0272 162-0277 162-0282 162-0287
FAR UV QUARTZ (170–2700 nm)
5 0.70 162-0288 162-0293 162-0298 162-0303
10 1.40 162-0289 162-0294 162-0299 162-0304
20 2.80 162-0290 162-0295 162-0300 162-0305
40 5.60 162-0291 162-0296 162-0301 162-0306
50 7.00 162-0292 162-0297 162-0302 162-0307
Micro Rectangular Cuvettes – 2 mm Opening
PATHLENGTH VOLUME WITH PTFE COVER/CLEAR WITH PTFE COVER/BLACK WALLED WITH PTFE STOPPER/CLEAR WITH PTFE STOPPER/BLACK WALLEDmm mL PART NUMBER PART NUMBER PART NUMBER PART NUMBER
OPTICAL GLASS (320–2500 nm)
5 0.35 162-0308 162-0313 162-0318 162-0323
10 0.70 162-0309 162-0314 162-0319 162-0324
20 1.40 162-0310 162-0315 162-0320 162-0325
40 2.80 162-0311 162-0316 162-0321 162-0326
50 3.50 162-0312 162-0317 162-0322 162-0327
FAR UV QUARTZ (170–2700 nm)
5 0.35 162-0328 162-0333 162-0338 162-0343
10 0.70 162-0329 162-0334 162-0339 162-0344
20 1.40 162-0330 162-0335 162-0340 162-0345
40 2.80 162-0331 162-0336 162-0341 162-0346
50 3.50 162-0332 162-0337 162-0342 162-0347
O R D E R I N G I N F O R M AT I O N
11_UV-Vis 12-13-12_11_UV-Vis 12/13/12 1:35 PM Page 128
129
UV
-VI
SA
CC
ES
SO
RI
ES
Vials and Disposable CuvettesPART NUMBER DESCRIPTION
162-0205 5 mm Disposable Glass Vials, 6 mm x 50 mm (200/pk)
162-0208 8 mm Glass Vials (200/pk)
162-0212 12 mm Glass Vials (200/pk)
162-0348 Polystyrene, Disposable Cuvettes, 10 mm pathlength, 4.5 mL (100/pk)
162-0349 Polystyrene, Semi-micro Disposable Cuvettes, 10 mm pathlength, 1.5 mL (100/pk)
O R D E R I N G I N F O R M AT I O N
Cell Holders, Spacers and Stoppers PART NUMBER DESCRIPTION
111-3650 Cuvette Holder, 10 mm
111-3660 Adjustable Cuvette Holder 10–100 mm
161-2530 Slide Sample Holder, Cylindrical Cell, 10–20 mm
161-2540 Slide Sample Holder, Cylindrical Cell, 50 mm
161-2550 Slide Sample Holder, Cylindrical Cell, 100 mm
162-1201 Spacer for 1 mm Pathlength Cuvette
162-1202 Spacer for 2 mm Pathlength Cuvette
162-1205 Spacer for 5 mm Pathlength Cuvette
Notes: Please contact PIKE Technologies for replacement Teflon stoppers, covers,and for items not described on this list.
10 mm Cuvette Holder Adjustable Cuvette Holder
Cylindrical Cell Holder Spacers for 1, 2 and 5 mm cells
Cylindrical Cells with Teflon Stoppers – 22 mm Diameter
PATHLENGTH VOLUME OPTICAL GLASS FAR UV QUARTZ NIR QUARTZmm mL 320–2500 nm 170–2700 nm 220–3800 nm
10 2.80 162-1831 162-1841 162-1801
20 5.60 162-1832 162-1842 162-1802
50 14.10 162-1835 162-1845 162-1805
100 28.20 162-1840 162-1850 162-1810
11_UV-Vis 12-13-12_11_UV-Vis 12/13/12 1:35 PM Page 129
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
130
UV-Vis Polarizers – Manual and Automated Versions
The sample material and sampling configuration dictate theneed for a UV-Vis polarizer. Typical materials that may require apolarizer during sampling are often crystals, films, paints, beamsplitters, coated glass, and anti-reflective, and anti-glare coatings.Additionally, we recommend using a polarizer for specularreflectance sampling at an angle of incidence greater than 15 degrees where the reflectivity becomes polarization dependent.
F E AT U R E S O F T H E U V - V I S P O L A R I Z E R S
• Glan-Taylor and UV Glan-Thompson designs
• High grade calcite
• High extinction ratio
• Manual versions – 1 degree settable scaling
• Automated version – 0.1 degree scaling resolution
• Fits in a standard 2 inch x 3 inch mount
Glan-Taylor field of view
UV Glan-Thompson field of view
O R D E R I N G I N F O R M AT I O N
UV-Vis Polarizers AccessoriesPA R T NUMB E R D E S C R I P T I O N
198-1623 Manual Glan-Taylor
198-1624 Manual UV Glan-Thompson
198-1625 Automated Glan-Taylor
198-1626 Automated UV Glan-Thompson
Note: Polarizers may not fit in the sample compartments of some smaller spectrophotometers. Please consult PIKE Technologies before placing an order.
UV-VIS POL ARIZERS SPEC IF ICAT IONS
Glan-Taylor UV Glan-Thompson
Material Calcite Calcite
Spectral Range 250–2300 nm 250–2300 nm
Clear Aperture 12 mm 14 mm
Extinction Ratio 5 x 10-5 1 x 10-4
Manual Polarizer 29 x 50 x 146 mm 49 x 50 x 146 mmDimensions (W x D x H)
Automated Polarizer 56 x 50 x 146 mm 56 x 50 x 146 mmDimensions (W x D x H)
Angular Resolution, Manual 1° 1°
Angular Resolution, Automated 0.1° 0.1°
PIKE Technologies offers Glan-Taylor and Glan-Thompson UV-Vispolarizers. These take advantage of the birefringent properties of UV-quality calcite. An air interface is assembled between tworight angle calcite prisms in the Glan-Taylor polarizer whereas a UV-transparent cement separates the calcite prisms in the Glan-Thompson polarizer. In both styles, the polarized extraordinaryray passes through both prisms and the ordinary ray is internallyreflected and absorbed. The spectral range of these polarizers is250–2300 nm. Due to the natural origin of calcite the achievableminimum wavelength fluctuates from polarizer to polarizer.However, at 250 nm the transmission throughput is no less than 25%.
Wavelength (nm) 2 5 0 300 400 > 500
Minimum Transmission (%) 2 5 4 0 65 85
Each polarizer type has a different field of view where theUV-Vis beam is polarized. The UV Glan-Thompson field of view iswider compared to the Glan-Taylor as shown in the figure.
Enhanced angular resolution of 0.1° is gained with the auto-mated version of the PIKE UV-Vis polarizer. This automated featureis advantageous where highly precise angular settings are requiredand for increasing the measurement simplicity for determining thepolarized orientation of a sample. By evaluating the transmission orreflectance of a sample as a function of the automated polarizerangle at a given wavelength, parallel and perpendicular orientationof the sample relative to the polarizer degree setting may bedetermined. The automated version includes integrated data collection with some commercial UV-Vis spectrophotometer software packages.
11_UV-Vis 12-13-12_11_UV-Vis 12/13/12 1:35 PM Page 130
131
UV
-VI
SA
CC
ES
SO
RI
ES
UV-Vis Spec – Slide Mounted Specular Reflectance Accessories
PIKE Technologies relative fixed angle specular reflectance accessories for UV-Vis spectrophotometers span from near normalto grazing angle. This product sheet highlights our specularreflectance accessories featuring slide mount design. These covermid-range angles of incidence, between 15–60°, and may bealigned to maximize throughput.
In specular reflectance sampling, the light source is directed tocontact the sample at a given angle of incidence. Measured lightis collected from the equivalent angle. Typical samples includesemiconductors, anti-reflective coatings, color filters, semi-trans-parent and highly reflective mirrors, optical materials, reflectionfilters, multiple layers, solar mirrors, and solar controlling filmson glass. Measured parameters of interest include film thickness,material reflectivity, and coating uniformity and homogeneity.
F E AT U R E S A N D A P P L I C AT I O N S O F F I X E D A N G L E
S P E C U L A R R E F L E C TA N C E A C C E S S O R I E S
• Fixed angle reflectance accessories including 15, 20, 30, 45, and 60 degrees
• Slide mount design for easy installation
• Optical and anti-reflective coatings testing
• Gloss measurements
• Determining reflectivity of mirrors
• Film thickness calculations
Optical geometry schematic for mid-range fixed anglespecular reflectance accessory
Anti-reflective optics coating spectrum collected using the PIKE UV-Vis 60Spec
SPECUL AR REFLECTANCE ACCESSORY SPEC IF ICAT IONS
Mounting Method Slide mount
Accessory Dimensions
Slide Mount (W x D x H) 95 x 51 x 76 mm
Mask Aperture 4 mm x 7 mm
Optical Mirrors UV optimized aluminum
O R D E R I N G I N F O R M AT I O N
Fixed Angle Specular Reflectance AccessoriesPA R T NUMB E R D E S C R I P T I O N
121-1500 UV-Vis 15Spec
121-2000 UV-Vis 20Spec
121-3000 UV-Vis 30Spec
121-4500 UV-Vis 45Spec
121-6000 UV-Vis 60Spec
300-0300 UV Aluminum Mirror (25.4 mm x 25.4 mm)
121-0500 Aperture Mask (4 mm x 7 mm)
11_UV-Vis 12-13-12_11_UV-Vis 12/13/12 1:35 PM Page 131
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
132
UV-VIS 85Spec – Specular Reflectance Accessory
F E AT U R E S O F T H E U V - V I S 8 5 S P E C
• Small footprint, compact design
• Fixed 85 degree angle of incidence
• Baseplate mount for stable operation and collection of high quality spectra
• Thin films and coatings measurements
AR coated ZnSe crystal measured using the 85Spec Specular Reflectance Accessory.
UV-V I S 85S P E C S P E C I F I C AT I O N S
Mounting Method Baseplate
Dimensions (W x D x H) 105 x 84 x 76 mm
Mask Aperture 35 x 3 mm
Optical Mirrors UV optimized aluminum
Optical diagram of the UV-Vis 85Spec Specular Reflectance Accessory
The 85Spec is an 85 degree specular reflectance accessory developed for UV-Vis applications. The accessory is used to analyzemirror-like planar surfaces and thin films on planar surfaces. The grazing angle (85°) measurements give the longest possiblepathlength through coated samples.
Pre-mounted on a baseplate specific to your UV-Vis spectrophotometer, the 85Spec is an easy-to-use accessory. The mounting allows the 85Spec to be inserted and removedfrom the sample compartment without alignment.
O R D E R I N G I N F O R M AT I O N
UV-Vis Specular Reflectance AccessoryPA R T NUMB E R D E S C R I P T I O N
121-85XXX UV-Vis 85Spec – Specular Reflectance AccessoryIncludes an Al substrate alignment mirror and sample mask
Note: XXX are instrument codes listed in the table below.
UV-Vis 85Spec Replacement PartsPA R T NUMB E R D E S C R I P T I O N
300-0301 UV Aluminum Mirror (38.1 mm x 38.1 mm)
121-0501 Aperture Mask (35 mm x 3 mm)
XXX Spectrophotometer CodesCOD E S P E C T RO PHOTOM E T E R
100 Agilent/Varian – Cary 50
110 Agilent/Varian – Cary 100, 300
120 Agilent/Varian – Cary 4000, 5000, 6000i
600 Jasco – 600 series
700 PerkinElmer Lambda 650, 750, 850, 950 and 1050
730 PerkinElmer – Lambda 25, 35, 45
200 Shimadzu – 1600 and 1700
210 Shimadzu – 1800 Series
400 Thermo Fisher Scientific – Evolution 300/600
410 Thermo Fisher Scientific – Evolution 200
Note: Contact PIKE Technologies if you do not find your spectrophotometer code listed.
11_UV-Vis 12-13-12_11_UV-Vis 12/13/12 1:35 PM Page 132
133
UV
-VI
SA
CC
ES
SO
RI
ES
UV-Vis VeeMAX – Variable Angle Specular Reflectance Accessory
FEATURES AND APPLICATIONS OF THE UV-VIS VEEMAXVARIABLE ANGLE SPECULAR REFLECTANCE ACCESSORY
• Selectable angle of incidence – from 30 to 80 degrees in one degree increments
• Film and coating thickness measurements at optimized angle of incidence
• Grazing angle measurements for the longest path through an ultra-thin films
• Characterization of variable reflectivity materials
Optical geometry schematic for UV-Vis VeeMAX variable angle specular reflectance accessory
Specular reflectance collected at two different angles of incidence (AOI)for an anti-reflective coating
UV-V I S V E E MAX S P E C I F I C AT I O N S
Mounting Method Baseplate
Nominal Accessory Dimensions 145 x 135 x 158 mm(W x D x H) (dimensions vary with spectrophotometer type)
Minimum Beam Height 50 mm
Mask Aperture 7 mm x 4 mm13 mm x 4 mm25 mm x 4mm
Optical Mirrors UV optimized aluminum
O R D E R I N G I N F O R M AT I O N
UV-Vis VeeMAX AccessoryPA R T NUMB E R D E S C R I P T I O N
013-10XXX UV- Vis VeeMAX Variable Angle Specular Reflectance Accessory
Note: Contact PIKE for the XXX spectrophotometer code.
UV-Vis VeeMAX Replacement PartsPA R T NUMB E R D E S C R I P T I O N
300-0300 UV Aluminum Mirror (25.4 mm x 25.4 mm)
013-4015 Aperture Mask Set (7 mm, 13 mm, and 25 mm x 4 mm)
XXX Spectrophotometer CodesCOD E S P E C T RO PHOTOM E T E R
100 Agilent/Varian – Cary 50
110 Agilent/Varian – Cary 100, 300
120 Agilent/Varian – Cary 4000, 5000, 6000i
600 Jasco – 600 series
700 PerkinElmer Lambda 650, 750, 850, 950 and 1050
730 PerkinElmer – Lambda 25, 35, 45
200 Shimadzu – 1600 and 1700
210 Shimadzu – 1800 Series
400 Thermo Fisher Scientific – Evolution 300/600
410 Thermo Fisher Scientific – Evolution 200
Note: Contact PIKE Technologies if you do not find your spectrophotometer code listed.
In specular reflectance sampling, the light source is directed tocontact the sample at a given angle of incidence. Measured lightis collected from the equivalent angle. Typical samples includesemiconductors, anti-reflective coatings, spectral wavelength filters,semi-transparent and highly reflective mirrors, optical materials,reflection filters, multiple layers, solar mirrors, and solar controllingfilms on glass. Measured parameters of interest include film thickness,material reflectivity, and coating uniformity and homogeneity.
With the UV-Vis VeeMAX™ accessory find versatility for specularreflectance measurements. The angle of incidence from 30 to 80°is easily changed by turning the angle setting dial. This flexibilityallows for optimization of spectra quality for film and coatingmeasurements. In other applications where it is desirable to study the effect of incident angle upon reflected radiation, the UV-Vis VeeMAX offers a sampling solution. Typical sample materials
are reflectors, bandpass filters, and hot and cold mirrors. The UV-VisVeeMAX makes an ideal accessory used to replicate real-world situations such as the effect of a rising and setting sun on absorbanceefficiency of solar collectors and architectural glass performance.
11_UV-Vis 12-13-12_11_UV-Vis 12/13/12 1:35 PM Page 133
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
134
Falcon UV-VIS – Precise Cell Temperature Control Accessory
F E AT U R E S O F T H E FA L C O N U V - V I S
• Fast and easy analysis of samples under precise Peltier temperature control
• Choice of cuvette and vial adapters
• Compatible with 1 mm to 10 mm pathlength cuvettes anddisposable 5 mm to 12 mm vials
• Excellent thermal accuracy and precision
• Available for selected UV-Vis spectrophotometers
The PIKE Technologies UV-Vis Cell Temperature Control Accessoryis an excellent choice for analysis of liquid samples that requireprecise temperature control. The accessory is well suited for pharmaceutical, life science and general industrial applications.Temperature range of the accessory is 5 °C to 130 °C with +/- 0.5%accuracy. Heating and cooling is controlled by a built-in Peltierdevice. The Peltier element provides for reproducible rampingand for reaching target temperatures quickly and reliably. Thesystem is driven by a Digital Temperature Controller – directly, orvia PC. Individual sample holders are designed to accommodatestandard 1 mm to 10 mm cuvettes (1, 2 and 5 mm cuvettes requireuse of spacers) and 5 mm, 8 mm and 12 mm glass vials. Sampleholders are pin positioned to ensure maximum reproducibility.
The complete Falcon UV-VIS configuration requires the accessorybase, cell holder, and one of the available temperature controllers.The Falcon accessory is compatible with a selected range of UV-Vis spectrophotometers.
FA L C O N UV-V I S S P E C I F I C AT I O N S
Temperature Control Peltier (cooling and heating)
Temperature Range 5 °C to 130 °C
Accuracy +/- 0.5%
Voltage 15 VDC
Sensor Type 3 wire Pt RTD (low drift, high stability)
Temperature Controllers
Digital +/- 0.5% of set pointDigital PC +/- 0.5% of set point, graphical setup,
up to 10 ramps, USB interface
Input Voltage 90–264 V, auto setting, external power supply
Output Voltage 16 VDC/150 W max.
Dimensions (W x D x H) 120 x 175 x 90 mm (without the spectrophotometer baseplate and mount)
Notes: Peltier device must be water cooled for proper operation – this is achievedby running cold tap water through the water jacket integrated into the accessoryshell, or by the use of an external liquid circulator.
O R D E R I N G I N F O R M AT I O N
Heated UV-Vis Transmission AccessoryPA R T NUMB E R D E S C R I P T I O N
110-60XXX UV-Vis Falcon BaseIncludes: Temperature controlled base. Digital TemperatureController and sample holder need to be selected from thetables below for complete system.
Note: Please insert XXX code found at the spectrophotometer table at the bottom ofthis page.
Temperature ControllersPA R T NUMB E R D E S C R I P T I O N
076-1230 Digital Temperature Control Module
076-1430 Digital Temperature Control Module PC Control (USB)
Sample Holders and SpacersPA R T NUMB E R D E S C R I P T I O N
111-3610 5 mm Vial Holder
111-3620 8 mm Vial Holder
111-3630 12 mm Vial Holder
111-3640 1 cm Cuvette Holder
162-1201 Spacer for 1 mm Cuvette
162-1202 Spacer for 2 mm Cuvette
162-1205 Spacer for 5 mm Cuvette
Notes: Spacers for short pathlength cuvettes are designed to work only with 1 cmCuvette Holder.
Please refer to pages 128–129 of this catalog for the selection of cuvettes and vials available for this accessory.
OptionsPA R T NUMB E R D E S C R I P T I O N
170-1000 Liquid Recirculator
XXX Spectrophotometer CodesCOD E S P E C T RO PHOTOM E T E R
100 Agilent/Varian – Cary 50
110 Agilent/Varian – Cary 100, 300
120 Agilent/Varian – Cary 4000, 5000, 6000i
600 Jasco – 600 series
700 PerkinElmer Lambda 650, 750, 850, 950 and 1050
730 PerkinElmer – Lambda 25, 35, 45
200 Shimadzu – 1600 and 1700
210 Shimadzu – 1800 Series
400 Thermo Fisher Scientific – Evolution 300/600
410 Thermo Fisher Scientific – Evolution 200
Note: Contact PIKE Technologies if you do not find your spectrophotometer code listed.
11_UV-Vis 12-13-12_11_UV-Vis 12/13/12 1:35 PM Page 134
135
UV
-VI
SA
CC
ES
SO
RI
ES
Peltier-Controlled Cuvette Holders for UV-Vis Spectrophotometers –Experiments Under Tightly Controlled Temperature Conditions
The new series of PIKE Technologies Peltier accessories includesair- and liquid-cooled cuvette holders, two-channel TemperatureController and optional Liquid Recirculator.
The cuvette holder can be used with single- and dual-beamspectrophotometers (two identical units are required for dual-beamconfiguration) and can be independently driven by the DigitalTemperature Controller. Each cuvette holder features an efficientheat exchange design and variable speed magnetic stirrers. Bothunits use a thermoelectric cooler based on Peltier principle andutilize air or liquid flow for excess heat removal. The temperaturerange for the air-controlled unit is 20 °C to 60 °C. Its cell body ismade from Delrin and an integrated copper insert provides highlyefficient heat transfer.
The cuvette holders are designed to accommodate standardsize 10 mm x 10 mm cuvettes and shorter path cuvettes withappropriate spacers. The holders fit in most makes of UV-Vis spectrophotometers and are available in 8.5 mm and 15 mmbeam height configurations.
The Temperature Controller offered with the Peltier-ControlledCuvette Holders supports two channels. For the single cuvetteholder configuration, the first channel can be used for monitoringand control of the block temperature and the second for moni-toring of the sample temperature (this configuration can be alsoreversed, where the sample temperature is driving the heating/cooling action). For the two holder configuration, a single controllercan be used to control each device independently or two controllerscan be used to control and monitor block and sample temperaturesof each cuvette holder. The Temperature Controller is equippedwith a color touch-screen and features intuitive, menu-driven programming. Single set points orsimple ramping functions can be pre-programmed and performedby this device. Custom PIDparameters can be implementedto modify and fine-tune controllerfunctions. The accessory is equippedwith precision RTDs for reliableand reproducible operation.
PC control is also available for this Peltier system. The digital controller can be connected to the computer via a USBport. PIKE TempPRO software provides functions required foraccessory programing, setting of temperature points, rampingand experiment monitoring.
F E AT U R E S O F T H E P E LT I E R - C O N T R O L L E D
C U V E T T E H O L D E R S
• Precision temperature control
• Single- and dual-beam configurations
• Two temperature range options
• Dedicated controller and PC control
• Built-in magnetic stirring
Dedicated TemperatureController main menu
PIKE TempPro software for kinetic experiments
S P E C I F I C AT I O N S
Cuvette Holders
Temperature Range
Air-Cooled 20–60 °C
Liquid-Cooled -5–110 °C
Precision +/- 0.1 °C
Temperature Accuracy
Air-Cooled +/- 0.1 °C from 20 °C to 60 °C
Liquid-Cooled +/- 0.1 °C from -5 °C to 110 °C
RTD Probe 3 Wire Pt RTD (low drift, high stability)
Stirring Speeds Low, Medium, High
Cuvette Size 12.5 mm x 12.5 mm (accommodates smallersize with appropriate spacers)
Z-height 8.5 mm and 15 mm (must specify)
Temperature Controller
Precision +/- 0.1 °C
Channels Two
Functions Set Point, Temperature Ramping, Custom PID Setup
Computer Interface USB
Input Voltage 90–264 V, auto setting, external power supply
Output Voltage 15 VDC/60 W max.
Dimensions (W x D x H) 83 x 105 x 85 mm
O R D E R I N G I N F O R M AT I O N
PA R T NUMB E R D E S C R I P T I O N
110-50XXX Single Position Cuvette Holder – Air-Cooled
110-70XXX Single Position Cuvette Holder – Liquid-Cooled
076-1250 Peltier Temperature Control Unit
076-1450 USB Peltier Temperature Control Unit
162-1900 RTD Probe
170-1000 Liquid Recirculator
007-0200 PIKE TempPRO Software
162-1905 Magnetic Stirring Bar (5 mm)
162-1201 Spacer for 1 mm Cuvette
162-1202 Spacer for 2 mm Cuvette
162-1205 Spacer for 5 mm Cuvette
Note: Must specify make and model of the spectrophotometer. Temperature ControlUnit must be selected.
11_UV-Vis 12-13-12_11_UV-Vis 12/13/12 1:35 PM Page 135
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
136
Out-of-Compartment Microplate Reader – Plate Reading Option for UV-Vis Spectrophotometers
F E AT U R E S O F T H E M I C R O P L AT E R E A D E R
• Microplate reading option for standard UV-Vis spectrophotometers
• Scanning and fixed wavelength measurements (spectrophotometer dependent)
• Two fiber optic cables or one cable and on-board detectorconfigurations
• 6-well to 384-well microplate reading capability
• Custom configurations for automated sampling
The PIKE Technologies Out-of-Compartment Microplate Reader isa unique option available for most UV-Vis spectrophotometers. It offers high throughput plate reading capability to a wide rangeof traditional instruments with standard sample compartments.This allows for flexibility when conducting experiments thatrequire optical configuration for cuvettes, temperature control,integrating spheres (among others) and extra microplate readingfunctionality when needed. Microplate reading capability is oftenrequired in research, drug discovery, bioassay validation, qualitycontrol and manufacturing processes in the pharmaceutical andbiotechnological industry and academia. The PIKE MicroplateReader can also be adapted to perform automated measurementsof filters, optical components and other materials.
The Microplate Reader module features a small footprint and can be positioned next to or above the spectrophotometer.For instruments that do not support an external detector, theoptical configuration features a transfer optics module mountedin the sample compartment and “light out” and “light in” opticalfiber cables that mount to the reader’s frame. For spectrometerswith external detector support, the light is sent to the accessoryvia a single optical fiber cable and collected by an on-board photodiode detector.
The mechanical design of theaccessory relies on an X, Y stage with both axes driven by highprecision servo motors with optical encoders for speed and reproducibility. USB and DC powerare the only external connectionsrequired for this accessory.
Programming and control of the Microplate Reader is donethrough PIKE Technologies AutoPRO software, which can be integrated easily with many third-party UV-Vis software packages.
M I C R O P L AT E R E A D E R S P E C I F I C AT I O N S
Optics Transfer Optics Module and two UV-Vis/NIROptical Fiber Cables or, Transfer OpticsModule, one Optical Fiber Cable and Photodiode Detector
Accuracy +/- 25 µm
Mechanical Specifications
Repeatability +/- 5 µm
Resolution 1 µm
Run Time 96-well plate – 32 seconds384-well plate – 84 seconds
Computer Interface USB
Power Requirements 100–240 Volts AC 50/60 Hz
Dimensions (W x D x H) 11.6 x 13.7 x 6"
Weight 15 lbs
O R D E R I N G I N F O R M AT I O N
Out-of-Compartment Microplate ReaderPA R T NUMB E R D E S C R I P T I O N
047-10XXX Microplate Reader Accessory
Required Optical Components (must select Transfer Optics Module and twoFiber Optic Cables, or Transfer Optics Module, one Fiber Optic Cable andPhotodiode Detector) PA R T NUMB E R D E S C R I P T I O N
047-11XXX Transfer Optics Module
047-3010 Photodiode Detector
047-3020 UV-Vis/NIR Optical Fiber Cable
Note: Contact PIKE Technologies to verify that the accessory is compatible with yourspectrophotometer.
AutoPRO Software – Plate Reader configuration screen
11_UV-Vis 12-13-12_11_UV-Vis 12/13/12 1:35 PM Page 136
137
UV
-VI
SA
CC
ES
SO
RI
ES
Automated XY, R-Theta and Y-rotation Stages for UV-Vis Spectrophotometers
PIKE Technologies offers a wide range of computer controlledaccessories for translating and rotating samples in the spectro -photometer beam. These tools enable mapping of sample surfacesand generating spectroscopy data as a function of sample position.Suitable for determination of film and coating thickness, multilayerfilm analysis, reflectivity studies, and characterization of opticalmaterials. Applications include transmittance and specular reflectancemeasurements at normal and variable incident light angles. XY control for microplate type configurations (in-sample compartment and with optical fibers) is also available.
Vertical and Horizontal R-Theta, Translation/Rotation These accessories are suitable for analyzing small and large sizesamples including coated and uncoated glass, optical filters, solarpanels and similar materials. The support ring mounts on theaccessory’s drive and is rotated and translated laterally to producean R-theta motion covering the entire sampling range of theaccessory. Each system incorporates two precision stepper motors for rotation and translation of the plate.
Vertical XY Sampling StageDesigned for research type UV spectrophotometers and typicallyused for precision mapping of large, flat samples. Suitable forthin coating studies and material quality control. Uses similar to R-Theta accessory sample mount, but samples are translatedvertically and horizontally by precision stepper motors.
Out-of-Compartment Microplate ReaderThis accessory is designed to work with standard 24-, 48- or 96-well microplates but can be also modified to accommodateother sample shapes. The unit features a horizontal XY stage withboth axes driven by high precision stepper motors for speed andreproducibility.
RotatIR, for %T/A Measurements at Various Beam ofIncidence AnglesThis accessory is designed for automated selection of the trans-mission angle of the UV-Vis beam that enters the sample. This isachieved by mounting and rotating the sample in the adjustableangle holder. A full set of spectral data may be collected by pre-defining the required measurement angles from the software. TheRotatIR features a standard 2" x 3" slide mount for easy positioningof different types of transmission samples and sample holders.
The operation is managed by the AutoPRO™ software which providesfull user programmability and easy to learn “point-and-click”environment. Polar or X and Y coordinates may be used to definetest points. The AutoPRO software allows complex test sequencesto be set up, stored as methods and implemented for full flexibility.
Each automated accessory is tailored to meet specific sampling needs. This includes adjustments for sample shape/size,and the type of spectroscopic data required. Please contact PIKE Technologies to verify that the selected stage can be integrated into your spectrophotometer’s sample compartmentand produce desired information.
11_UV-Vis 12-13-12_11_UV-Vis 12/13/12 1:35 PM Page 137
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-2
74-2
721
138
N O T E S
11_UV-Vis 12-13-12_11_UV-Vis 12/13/12 1:35 PM Page 138
Standards, Software and Databases We strive to provide you with useful sampling
tools for spectroscopy and offer these additional
products and information to serve your laboratory
requirements. If you have not found the exact
sampling tool or information within our catalog,
please contact us. Your spectroscopy sampling
requirements may become one of our product
offerings of the future.
Spectral Databases ATR and Transmission Versions for Your FTIR
Page 144
PIKECalc™ SoftwareFor FTIR sampling computations
Page 143
Reference Standards For Calibrating Your Spectrometers
Page 140
12_StandSoftDatabases 12-13-12_12_StandSoftDatabases 12/13/12 1:37 PM Page 139
Reference Standards – For Calibrating FTIR Spectrometers
FTIR spectrometers are highly accurate and reliable measurementtools. Their internal referencing laser (Connes advantage) is agreat leap forward in wavenumber accuracy and repeatability.Still it is often required by regulatory agencies and operating procedures, to calibrate the spectrometer. PIKE Technologiesoffers several new products to assist in this task.
PIKE Technologies offers several versions of polystyrene reference materials for FTIR spectrometer calibration. The 1.5 miland 55 micron thick polystyrene are generally specified for cali-brating wavenumber accuracy. PIKE also offers a NIST traceablepolystyrene version of these products which includes the referencematerial, calibration result for the material and its traceabilitydocumentation.
The Specular Reflectance Standard is a unique material for calibration of your reflectance measurement system. The standard isa specially treated germanium element which only allows reflectionfrom its front surface – thereby providing a reflection value whichcan be calculated relative to Fresnel equations. The SpecularReflectance Standard includes documentation to trace the specularreflectance to published refractive index data.
The Specular Reflectance Standard is compatible with the following PIKE Technologies products; VeeMAX III, 30Spec, 45Specand 10Spec.
140
FEATUR E S O F RE F E R EN C E S TANDARD S
• Mid-IR and NIR spectral regions products
• Transmission, reflection and ATR versions
• Traceable versions available
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-274-2721
140
Polystyrene Reference Standards – for calibrating FTIR wavenumber accuracy
Specular Reflectance Standard – for calibrating reflectance measurement system
Comparison of measured and calculated reflectance for the SpecularReflectance Standard using the PIKE 10Spec accessory
Polystyrene Reference StandardsPA R T NUMB E R D E S C R I P T I O N
162-5420 1.5 mil Polystyrene Reference Standard
162-5440 55 micron Polystyrene Reference Standard
162-5450 NIST Traceable 1.5 mil Polystyrene Reference Standard
Notes: Polystyrene reference standards are mounted in a 2" x 3" card and are compatible with all FTIR spectrometers.
Specular Reflectance StandardPA R T NUMB E R D E S C R I P T I O N
162-5460 Specular Reflectance Standard
Notes: Compatible with 10Spec, 30Spec, 45Spec and VeeMAX III.
ORDER I NG IN FORMAT I ON
12_StandSoftDatabases 12-13-12_12_StandSoftDatabases 12/13/12 1:37 PM Page 140
141
STANDARDS, S
OFTWARE
ANDDATABASES
For diffuse reflectance measurements in the NIR and UV-Visiblespectral region, it is often desirable to measure against the highestpossible reflectance material. The NIR and UV-Vis DiffuseReflectance Standards are available in highly reflective diffusegold and PTFE. Each standard is certified against a NationalResearch Council of Canada traceable plaque standard.
Diffuse reflectance sampling in the mid-infrared region isused to measure the reflectance of powders, films, painted panels,and other samples. Exhibiting sharp peaks throughout the mid-IRspectral region, the Mid-IR Diffuse Reflectance WavelengthStandard is used to verify and calibrate for wavelength accuracyfor diffuse reflectance measurements. This standard is NIST traceable to NIST 1921b and an analysis certificate is included.
Diffuse Gold Reference Standard
Measured reflectivity of Diffuse Gold Reference Standard
Mid-IR Diffuse Reflectance Wavelength Standard
Mid-IR Diffuse Reflectance Standard spectrum
NIR and UV-Vis Diffuse Reflectance StandardsPA R T NUMB E R D E S C R I P T I O N
162-5480 Diffuse PTFE Reference (0.9" optical diameter)
162-5481 Diffuse Gold Reference (0.9" optical diameter)
162-5482 Diffuse Gold Reference (1.7" optical diameter)
Mid-IR Diffuse Reflectance StandardsPA R T NUMB E R D E S C R I P T I O N
162-5485 Mid-IR Diffuse Reflectance Wavelength Standard (1.75" optical diameter)
162-5486 Mid-IR Diffuse Reflectance Wavelength, recertification
ORDER I NG IN FORMAT I ON
12_StandSoftDatabases 12-13-12_12_StandSoftDatabases 12/13/12 1:37 PM Page 141
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-274-2721
142
ATR spectra are somewhat different than those produced bytransmission sampling techniques – both in relative intensity ofthe absorbance bands and also the position of the bands.
To assist with calibrating your ATR/FTIR system, PIKETechnologies offers a new ATR Reference Standard. The ATRReference Standard is available as a standard material and also ina version which includes a recommended validation procedurefor your ATR/FTIR system.
In the near infrared (NIR) spectral region, PIKE Technologiesoffers its NIR Wavelength Standard for calibrating a NIR spec-trometer. The NIR Wavelength Standard meets USP wavelengthrequirements, provides calibration beyond 2.0 µm and is NISTtraceable. This standard is compatible with NIR analysis in the diffuse reflectance sampling mode. The NIR Wavelength Standardincludes analysis certificate and traceability documentation.
ATR Reference Standard
ATR Reference Standard Spectrum
NIR Wavelength Standard
NIR Wavelength Standard Spectral Data. (Upper green spectrum) PIKENIR Wavelength Standard. (Lower red spectrum) NIR standard fromanother supplier.
ATR Reference StandardPA R T NUMB E R D E S C R I P T I O N
162-5470 ATR Reference Standard
162-5475 ATR Reference Standard with Recommended ValidationProcedure and Validation Certificate
162-5476 ATR Reference Standard, recertification
Notes: Compatible with MIRacle, GladiATR and VeeMAX III with ATR.
NIR Wavelength StandardPA R T NUMB E R D E S C R I P T I O N
048-3070 Traceable NIR Reference Standard (0.9" optical diameter)
048-3071 Traceable NIR Reference Standard, recertification
Notes: Includes traceability measurement documentation.
ORDER I NG IN FORMAT I ON
12_StandSoftDatabases 12-13-12_12_StandSoftDatabases 12/13/12 1:37 PM Page 142
143
STANDARDS, S
OFTWARE
ANDDATABASES
PIKECalc software is easy-to-use – just select the type of computation,enter values from your spectral data and click on the calculatebutton. An instant calculation is performed.
PIKECalc eliminates the need to search through literature references to find the correct conversions and formulae and givesyou immediate results. All formulae and equations are documentedin the software, if you wish to reference our mathematics. Helpand how to use PIKECalc is included within the software.
PIKECalc is compatible with current versions of Microsoftoperating systems and is a free-standing program which can beused with all FTIR spectral data.
Please ask us about other FTIR spectroscopy calculations youmay need.
PIKECalc Software – For FTIR Sampling Computations
F E ATUR E S O F P IKECA LC
• Convert from wavelength (microns and nanometer) to wavenumber
• Calculate depth of penetration, critical angle, effective pathlength, effective angle of incidence and number ofreflections for ATR
• Calculate cell pathlength, thickness of free-standing film and thickness of coating
ORDER I NG IN FORMAT I ON
PA R T NUMB E R D E S C R I P T I O N
007-0300 PIKECalc Software
Notes: PIKECalc is loaded on a CD disk for upload to your PC and operates withcurrent versions of Microsoft operating systems.
12_StandSoftDatabases 12-13-12_12_StandSoftDatabases 12/13/12 1:37 PM Page 143
PIK
ETECHNOLOGIE
SWWW.PIK
ETECH.COM
608-274-2721
144
Spectral search is greatly improved when using databases collectedusing the same sampling mode – especially when the samplingmode is ATR. PIKE Technologies offers a large selection of ATRspectral databases.
The Aldrich ATR Spectral Database contains 18,513 spectra produced by the Aldrich Chemical Company. The collection includesorganic and inorganic compounds and also includes polymersand industrial chemicals. Spectral range is 4000–650 cm-1.
The IChem ATR Spectral Database contains 13,557 spectra produced by Fine Chemical manufacturers in Japan. This collec-tion includes organic and inorganic compounds, basic polymersand industrial chemicals. Spectral range is 4000–650 cm-1.
The Aldrich-IChem ATR Spectral Database Package includes36,639 spectra, a combination of all ATR spectra from both databases – with no duplicate entries.
A wide variety of applications spectral database packages areformed from the Aldrich ATR and the IChem ATR databases.
All spectral databases are supplied on a CD and operate withWindows® 2000 and Windows XP.
These spectral databases are compatible with ABB Horizon MB™,ACD/Labs, Bruker OPUS, Jasco Spectra Manager™ Suite, LumexSpectraLUM/Pro®, PerkinElmer Spectrum 10™, WinFirst™, ShimadzuIRSolution and HyperIR, LabControl SPECTACLE, Thermo ScientificOMNIC™, Varian Resolutions Pro™, GRAMS and Spectral ID softwarepackages. A USB port is required on your PC where a dongle isinstalled for copy protection.
ATR Spectral Databases – Optimize Search Results for ATR Spectral Data
ORDER I NG IN FORMAT I ON
ATR Spectral DatabasesPA R T NUMB E R D E S C R I P T I O N
008-1000 Aldrich ATR Spectral Database (18,513 spectra)
008-2000 IChem ATR Spectral Database (13,557 spectra)
008-3000 Aldrich-IChem ATR Spectral Database Package (36,639 spectra)
Notes: The spectral databases include a USB based device – dongle for copy protection. Please designate either 2 cm-1 or 4 cm-1 spectral data format.
ATR Application Specific Spectral DatabasesPA R T NUMB E R D E S C R I P T I O N
008-3002 ATR Applications – Polymers and Polymer Additives (4,520 spectra)
008-3003 ATR Applications – Food Additives and Food Packaging(2,762 spectra)
008-3004 ATR Applications – Solvents (667 spectra)
008-3005 ATR Applications – Organometallics and Inorganics (2,149 spectra)
008-3006 ATR Applications – Biochemicals (5,343 spectra)
008-3007 ATR Applications – Aldehydes and Ketones (3,482 spectra)
008-3008 ATR Applications – Alcohols and Phenols (2,671 spectra)
008-3009 ATR Applications – Esters and Lactones (4,170 spectra)
008-3010 ATR Applications – Hydrocarbons (1,175 spectra)
008-3011 ATR Applications – Flavors, Fragrances and Cosmetic Ingredients (2,716 spectra)
008-3012 ATR Applications – Pesticides (1,820 spectra)
008-3013 ATR Applications – Semiconductor Chemicals (919 spectra)
008-3014 ATR Applications – Forensic (3,579 spectra)
008-3015 ATR Applications – Dyes, Pigments and Stains (2,857 spectra)
008-3016 ATR Applications – Sulfur and Phosphorus Compounds (5,336 spectra)
008-3017 ATR Applications – Hazardous Chemicals (3,730 spectra)
008-3018 ATR Applications – Hazardous and Toxic Chemicals (8,136 spectra)
008-3020 ATR Applications – Pharmaceuticals, Drugs and Antibiotics(2,715 spectra)
008-3021 ATR Applications – High Production Volume (HPV) Chemicals(1,315 spectra)
008-3025 ATR Applications – Coatings (1,809 spectra)
008-3026 ATR Applications – Paints (2,507 spectra)
Notes: The spectral databases include a USB based device – dongle for copy protection. Please designate either 2 cm-1 or 4 cm-1 spectral data format. Specify yourFTIR software for correct format. Due to new additions or revisions to databases,spectral quantities may fluctuate. Please call for exact specifications at time of order.
F E ATUR E S O F ATR S P E C T RA L DATABA S E
• Select from databases with over 32,100 ATR spectra
• All spectra collected using FTIR spectrometers and a singlereflection ATR
• Complete collections and applications databases available
• Compatible with most FTIR software
12_StandSoftDatabases 12-13-12_12_StandSoftDatabases 12/13/12 1:37 PM Page 144
145
STANDARDS, S
OFTWARE
ANDDATABASES
PIKE Technologies offers a large collection of high quality, spectraldatabases collected in the transmission sampling mode.
The SDBS Transmission Spectral Databases include over50,000 spectra produced by Fine Chemical manufacturers in Japan.All spectra were collected at the Japanese National Laboratoriesunder highly controlled conditions with secondary verification ofthe materials by NMR and MS. Data is measured using severalsample preparation methods. Spectral range is 4000–400 cm-1.
The SDBS Transmission by KBr Pellet Spectral Database contains 22,995 spectra. This collection includes organic and inorganic compounds, basic polymers and industrial chemicals.
The SDBS Transmission by Liquid Film Spectral Database contains 7,018 spectra. This collection includes organic compoundsand industrial chemicals.
The SDBS Transmission by Nujol Mull Spectral Database contains 21,127 spectra. This collection includes organic and inorganic compounds and industrial chemicals.
A wide variety of applications spectral database packages areformed from the KBr Pellet and Liquid Film Spectral databases.
All spectral databases are supplied on a CD and operate withWindows® 2000, Windows XP, and Windows 7.
These spectral databases are compatible with ABB Horizon MB™,ACD/Labs, Bruker OPUS, Jasco Spectra Manager™ Suite, LumexSpectraLUM/Pro®, PerkinElmer Spectrum 10™, WinFirst™, ShimadzuIRSolution and HyperIR, LabControl SPECTACLE, Thermo ScientificOMNIC™, Varian Resolutions Pro™, GRAMS and Spectral ID softwarepackages. A USB port is required on your PC where a dongle isinstalled for copy protection.
ORDER I NG IN FORMAT I ON
Transmission Spectral DatabasesPA R T NUMB E R D E S C R I P T I O N
008-4001 SDBS Transmission by KBr Pellet Spectral Database (22,995 spectra)
008-4004 SDBS Transmission by Liquid Film Spectral Database (7,018 spectra)
008-4005 SDBS Transmission by Nujol Mull Spectral Database (21,127 spectra)
Notes: The spectral databases include a USB based device – dongle for copy protection. Please designate either 2 cm-1 or 4 cm-1 spectral data format.
Application Based Spectral DatabasesPA R T NUMB E R D E S C R I P T I O N
008-5002 Transmission Applications – Polymers and Polymer Additives (1,273 spectra)
008-5003 Transmission Applications – Food Additives and FoodPackaging (1,684 spectra)
008-5004 Transmission Applications – Solvents (668 spectra)
008-5005 Transmission Applications – Organometallics and Inorganics(1,445 spectra)
008-5006 Transmission Applications – Biochemicals (4,590 spectra)
008-5007 Transmission Applications – Aldehydes and Ketones (4,226 spectra)
008-5008 Transmission Applications – Alcohols and Phenols (2,744 spectra)
008-5009 Transmission Applications – Esters and Lactones (4,335 spectra)
008-5010 Transmission Applications – Hydrocarbons (1,417 spectra)
008-5011 Transmission Applications – Flavors, Fragrances andCosmetic Ingredients (1,912 spectra)
008-5012 Transmission Applications – Pesticides (958 spectra)
008-5013 Transmission Applications – Semiconductor Chemicals(664 spectra)
008-5014 Transmission Applications – Forensic (1,555 spectra)
008-5015 Transmission Applications – Dyes, Pigments and Stains(1,473 spectra)
008-5016 Transmission Applications – Sulfur and Phosphorus Compounds (5,025 spectra)
008-5017 Transmission Applications – Hazardous Chemicals (2,664 spectra)
008-5018 Transmission Applications – Hazardous and Toxic Chemicals (6,604 spectra)
008-5020 Transmission Applications – Pharmaceuticals, Drugs andAntibiotics (2,806 spectra)
008-5021 Transmission Applications – High Production Volume (HPV) Chemicals (1,123 spectra)
Notes: The spectral databases include a USB based device – dongle for copy protection. Please designate either 2 cm-1 or 4 cm-1 spectral data format. Specify yourFTIR software for correct format. Due to new additions or revisions to databases,spectral quantities may fluctuate. Please call for exact specifications at time of order.
Transmission Spectral Databases – High Quality Spectral Data for Optimized Search Results
FEATURES OF TRANSMIS S ION SPECTRAL DATABASE
• Select from databases with over 50,000 transmission spectra
• All spectra collected using FTIR spectrometers and transmissionsampling mode
• Complete collections and applications databases available
• Compatible with most FTIR software
12_StandSoftDatabases 12-13-12_12_StandSoftDatabases 12/13/12 1:37 PM Page 145
PIKETECHNOLOGIES
WWW.PIKETECH.COM
608-274-2721
146
Alphabetical Index
A
10Spec, Specular Reflectance 49
30Spec, Specular Reflectance 46
45Spec, Specular Reflectance 46
4X Beam Condenser 78
6X Beam Condenser 78
80Spec, Specular Reflectance 47
85Spec, UV-Vis 132
Abrasion Sampling Kit 40
Abrasion Sampling Disks, SiC 34, 36, 38, 40
Abrasion Sampling Disks, Diamond
34, 36, 38, 40
Absolute Reflectance Accessory 50
AGA, Specular Reflectance 48
Alignment Mirror, 10Spec, 30Spec 46, 47, 49
Alignment Mirror, 80Spec 47
Alignment Mirror, Diffuse Reflectance
34, 36, 38, 40
Alignment Mirror, VeeMAX III 45
AMTIR Crystal Plate, ATRMax 23
AMTIR Crystal Plate, HATR 18, 19
AMTIR, Properties 113
Analysis of Powders, Diffuse Reflectance 41
Angle of Incidence 51
Anvils for Die Kit 95, 96
Applications, Semiconductor Wafers
116, 117, 125
ATR, Cooled 13, 15, 19, 21, 22
ATR Crystal Properties 30, 31
ATR Crystals, Refractive Index 9, 30, 31
ATR Crystals, Spectral Range 9, 28, 29
ATR, GladiATR 12
ATR, GladiATR Vision 14
ATR, Heated 13, 15, 22
ATR, Products 7
ATR, Single Reflection 8, 12
ATR, Theory and Applications 29
ATR, Variable Angle 21, 24
ATRMax II, ATR Accessory 21
ATRMax II, Motorized 22
ATRMax II, Variable Angle ATR 22
ATR, MIRacle 8
ATR, VeeMAX 24
Auto-CrushIR Hydraulic Press 91
AutoDiff, Automated Diffuse Reflectance 38
Automated Diffuse Reflectance 38
Automated Specular Reflectance 43
Automated Transmission 60, 61, 82, 84
Automated Wafer Analysis 117
AutoPRO Software 22–26, 38, 39, 44, 45, 54,
82–85, 116–118, 136, 137
B
BaF2, Disks, Windows 75, 86, 87, 88, 91, 103,
104, 105, 107, 108, 110
BaF2, Properties 113
Beam Condensers 78
Beer-Lambert Law 111
Bolt Press 4, 95, 102
Boron 125
BPSG 126, 117, 125
C
CaF2, Disks, Windows 26, 54, 55, 75, 86, 87,
91, 103, 104, 105, 107, 110
CaF2, Properties 113
Carbide Blade, Micro Plane 74, 76
Card, Sample Holder 102
Catalytic Heat Chambers 35
Cell Holders 2, 3, 4, 86, 80, 89, 90, 94,
102, 103, 107, 116, 117, 128, 129
Cells, Long-Path, Quartz 89
Chunks, KBr 101, 103
Comprehensive Transmission Kit 3
Compression Cells 72, 74, 76
Compression Cells, Diamond 77
Constant Path Cells 88
Critical Angle 29
CrushIR 97, 98, 99
Cryostat190, Transmission Accessory 93
Crystal Polishing Kit 106
Crystals, Properties 29, 30, 113
CsI, Disks, Windows 59, 88, 103, 104,
105, 113, 124
CsI, Properties 113
Cuvette Holders 92, 129, 134, 135
Cuvettes 128
D
Degree of Polarization 29, 55
Delivery Terms 157
Demountable Liquid Cell 2, 3, 4, 86, 87, 91
Depth of Penetration 9, 21, 24, 28,
29, 30, 31, 143
Diamond ATR Probe 12, 44, 66, 67
Diamond Blade, Micro Plane 74, 76
Diamond Compression Cell 77
Diamond Crystal Plate, GladiATR 9
Diamond Crystal Plate, MIRacle 9, 11
Diamond, Properties 113
Diffuse Reflectance, Automated 38, 41
Diffuse Reflectance, Heating 35
Diffuse Reflectance, Products 33
Diffuse Reflectance, Theory and Applications 41
DiffusIR, Diffuse Reflectance 35
Digital Force Adapter for High-Pressure Clamp
10, 11, 13, 15, 16
Dilution, KBr 113
Disks, IR Materials 103, 104, 105
Disposable Cuvettes 129
E
EasiDiff, Diffuse Reflectance 3, 5, 6, 34
Educational Sampling Kit 4
Effective Pathlength 7, 17, 29, 30, 143
Electrochemistry 24
EPI 117, 125
Evanescent Wave 29, 30
External Sample Module 122
Extinction Ratio, Polarizers 55, 130
F
Falcon Mid-IR Transmission Accessory 90
Falcon NIR Transmission Accessory 92
Falcon UV-Vis Temperature Control 134
Fiber Optic Accessories 68, 136
Film Thickness 29, 43, 45, 46, 125, 131, 133
Flat Plate, ATRMax 21, 23, 24, 26
Flat Plate, HATR 18, 19
FlexIR, Mid-IR Fiber Optic Accessory 66, 67
FlexIR, NIR Fiber Optic Accessory 68
Flow-Through Attachment, MIRacle
and GladiATR 11, 13, 15, 16
Flow-Through Plate, HATR 18, 19, 20
Flow-Through Plate, MIRacle 11, 13
Fluorolube 2, 3, 4, 101, 113
Fringe Pattern 112, 125
FTIR Model Codes Fold out flap
G
Gas Analysis 107, 108, 109, 110, 119
Gas Cells, Flow-Through 107, 109, 110
Gas Cells, Heated 108, 109, 110
Gas Cell, Holders 102
Gas Cells, Long-Path 109, 110
Gas Cells, Short-Path 107
Gasera PA301, PA101 123, 124
GC-FTIR Interface 121
Ge Crystal Plate, GladiATR 12, 13, 16
Ge, Crystal Plate, HATR 18, 19, 20
Ge, Crystal Plate, MIRacle 9, 11
Ge, Disks, Windows 103, 104, 105
Ge, Properties 113
GladiATR 12, 13
GladiATR Options 16
GladiATR Vision 14, 15, 16
Grazing Angle, Applications 51, 52, 56
Grazing Angle, Specular Reflectance 47, 48
Grinder, ShakIR and Super ShakIR 100
Grinding, Samples 100
Guarantee 157
13_Index 12-13-12_39131 107-122 12/13/12 1:38 PM Page 146
147
INDEX
H
Hand Press 95
HATR 5, 17, 18, 19, 20, 21,
HATR, Out-of-Compartment 17
HATRPlus 17, 18, 19, 20
Heated, ATR 22, 23
Heated, Diffuse Reflectance 35
Heated Liquid Sample Holder 69
Heated Platens Accessory 97
Heated S84 Microscope 75
Heated Solid Transmission Accessory 94
Heated Transmission Cell 90
High-Pressure Clamps 10, 11
Holder, Pellets 2, 3, 95, 102
Holder, Sample Cards 94
Holders, Sample, Cell 78, 79, 83, 92, 102
Holder, Universal 2, 79, 102
Horizontal ATR (HATR) 2, 3, 5, 17, 18,
19, 20, 21, 102
How to Order 157
Hydraulic Die 95
Hydraulic Presses 95, 96, 97, 98, 99
I
Index of Refraction 41, 51
Infrared Reference Materials 113
Inserts for Auto Samplers 116, 118
Inserts for Wafer Holders 116, 118
Integrating Sphere, Mid-IR 58
Integrating Sphere, NIR 60
Integrating Sphere, Products 57
International Distribution 157
IR Disks, Windows 103, 104, 105, 106
J
JetStream ATR 27
K
KBr, Chunks, Powder 2, 3, 4, 34, 36, 38, 40,
42, 95, 96, 98, 99, 100, 101, 103
KBr, Dilution Ratio 113
KBr, Disks, Windows 36, 59, 74, 75, 76, 86, 87,
88, 91, 93, 108, 110, 120, 121
KBr, Pellet 2, 3, 4, 17, 34, 78, 79, 95,
96, 98, 99, 100, 102, 112, 145
KBr, Properties 113
Kit, Abrasion 35, 40, 42
Kit, Crystal Polishing 106
Kit, Reflectance Sampling 2, 5
Kit, Sample Preparation 5, 6, 34, 36, 40
Kit, Transmission Sampling 2, 3, 4
Kramers-KronigTransform 52
KRS-5, ATRMax Plates 19, 23
KRS-5, Disks, Windows 93, 103, 104, 105
KRS-5, HATR Plates 17, 20
KRS-5, VATR Crystal 28
Kubelka-Munk Conversion 42
L
Lambertian Scatterer 58, 59, 62, 63
Library Spectra 144, 145
Liquid Cells 86, 87, 88, 89, 90, 91
Liquid Cells, Demountable 2, 3, 4, 86, 87, 90
Liquid Cells, Holder 2, 3, 4, 86, 87
Liquid Cells, Sealed 88
Liquids Plate, MIRacle 11
Liquid Recirculator 36, 75, 90, 92, 94, 134, 135
Liquids Retainer and Volatiles Cover
11, 13, 15, 16
Liquid Sampling, Transmission 86, 87, 88, 89
Long-Path Gas Cells 109, 110
Long-Path Quartz Liquid Cells 89
M
Magnetic Film Holder 2, 3, 4, 96, 97, 98, 99, 102
MAP300 Inserts 117
MAP300, Wafer Analysis 117
MappIR Inserts 118
MappIR, Wafer Analysis 117
Masks, 10Spec 45, 49
Masks, 30Spec 6, 45, 46
Masks, 80Spec 45, 47
Masks, VeeMAX 23
Materials, IR properties 113
Micro ATR 73, 74
Micro Compression Cell 72, 74, 76
Micro Diamond Cell 73, 74, 77, 79
µMAX, IR Microscope 72, 73, 74, 76, 77, 112
Micro Plane 74, 76
Microplate Reader 136, 137
Microscope, Heated Stage 75
Microscope, IR 72, 73, 74, 76, 77, 112
Microscope, µMAX 72, 73, 74, 76, 77, 112
Microtiter Plates 39
Mid-IR, Falcon 90
MIRacle, ATR Accessory 8
MIRacle, Crystal Plates 8, 9, 10, 11
MIRacle, Flow-Through Options 11, 13
MIRacle, Heating Options 11
MIRacle, Pressure Clamps 11
Mirror, Alignment, 10Spec, 30Spec 46, 47, 49
Mirror, Alignment, 80Spec 47
Mirror, Alignment, AGA 48
Mirror, Alignment, VeeMAX 45
Monolayer Analysis 24, 44
Mortar and Pestle 2, 3, 4, 95, 96,
98, 99, 101, 112
Motorized VeeMAX 25, 26
Mull Cell 78, 79
Mull Cell, Holders 79
Mull Cell, Spacers 79
Mull Cell, Windows 79
Mull Agents 101
Multi-Reflection ATR 6, 17, 21, 30
Multi-SamplIR, Transmission 82
N
NaCl Disks and Windows 86, 87, 88, 91, 103,
104, 105, 107, 110
NaCl Properties 113
Needle Plate 87, 90, 91
NIR, AutoDiff 38
NIR, Heated Transmission 92
NIR, Diffuse Reflectance 35, 38
NIR, Falcon 92
NIR, X,Y Autosampler 39
NIST Traceable NIR Standard 61
NIST Traceable Polystyrene 140
Nujol 2, 3, 4, 101, 113, 145
Number of Reflections 22, 27, 28, 29, 30, 67, 109
O
Optical Materials 56, 103, 131, 133, 137
Ordering Information 157
O-Rings Die Kit 96
O-Rings, Liquid Cells 86, 87, 102
O-Rings, Mull Cells 86, 87, 102
Out-of-Compartment ATR 17
P
Pads, Crystal Polishing Kit 106
Payment Terms 157
Pellet Preparation 95, 96
Pellet Press 95, 96, 98, 99
Peltier Cuvette Holders 134, 135
Pestle 2, 3, 4, 5, 6, 34, 36,
95, 96, 98, 99, 101, 112
Photoacoustic Accessories 123, 124
PIKECalc Software 26, 143
Plate Reader 136, 137
Polarization, Thin Films 53, 55
Polarizers 55
Polarizers, Automated 54, 55
Polarizers, Manual 54, 55
Polarizers, UV-Vis 130
Polyethylene, Disks and Windows
86, 87, 93, 97, 103, 104, 105
Polyethylene, Properties 113
Polystyrene Reference Material 140
Powder, KBr 2, 3, 4, 34, 36, 38, 40, 42,
95, 96, 98, 99, 100, 101, 103
P-polarization 52
Press, Hydraulic 95, 96, 97, 98, 99
Press-On Mull Cell Holders 2, 3, 4, 80
Press Tips, MIRacle 11
Pressure Clamp, ATRMax 23
Pressure Clamp, GladiATR 13
Pressure Clamps, HATR 19
Pressure Clamps, MIRacle 11
Pressure Clamps, VeeMAX 24, 26, 28
Properties, IR Materials 113
13_Index 12-13-12_39131 107-122 12/13/12 1:38 PM Page 147
PIKETECHNOLOGIES
WWW.PIKETECH.COM
608-274-2721
148
Q
Quantitative Analysis 29, 30, 48, 60,
87, 88, 89, 90
Quartz Liquid Cells, Long-Path 89
R
Reference Materials, for FTIR 140
Reference Standards 140
Reflectance Sampling 3, 38, 41, 51
Reflection-Absorption 51
Returns, Product 157
Rotating Stage, IntegratIR 60, 61
RotatIR 83, 137
RotATR 73, 74
S
S84 Microscope Stage 75
Sample Cards 96, 98, 99, 102
Sample Cup, Diffuse 34, 36, 38, 40
Sample Cup Holder, Diffuse 34, 36,
Sample Grinder 100
Sample Holders, Transmission 93, 94, 102, 103
Sampling Kits 1, 2, 3, 4, 5, 6
Sample Module, External 122
Sample Preparation, Diffuse 40, 41, 112
Sample Preparation Kit 34, 36, 40
Sample Preparation, Transmission 111, 112, 113
Sample Vials, UpIR 37
Sealed Liquid Cells 88
Semiconductor Applications 125
Semiconductor Wafers 116, 117
Septum Cap for Gas Cells 107
ShakIR Sample Grinder 100
Short-Path Gas Cells 107
Si Crystal Plate for ATRMax 23
Si Crystal Plate for HATR 17, 19, 20
Si Crystal Plate for MIRacle 11
Si, Disks, Windows 86, 87, 91, 103, 104, 105
Si, Properties 113
Single Reflection ATR 6, 8, 12, 24
Single Reflection ATR, GladiATR 12
Single Reflection ATR, MIRacle 8
Single Reflection ATR, VeeMAX 24
SiO2, Disks, Windows 36, 88, 103, 104, 105
SiO2, Properties 113
Snell’s Law 51
Software, AutoPRO 22, 23, 24, 25, 26, 38, 39,
44, 45, 54, 82, 83, 85, 116, 117, 136, 137
Software, TempPRO 90, 92, 108, 135
Solid Sampling, ATR 28, 29
Solid Sampling, Diffuse 41
Solid Sampling, Transmission 111
Spacers, Demountable Cells 86, 87, 91
Spacers, Mull Cells 86
Special Applications 115
Spectral Databases 144
Specular Reflectance, 10Spec 49
Specular Reflectance, 30Spec 46
Specular Reflectance, 80Spec 47
Specular Reflectance, 85Spec, UV-Vis 132
Specular Reflectance, Absolute 50
Specular Reflectance, Automated 44
Specular Reflectance Standard 50, 140
Specular Reflectance, Theory, Applications 51
Specular Reflectance, VeeMAX 44
S-Polarization 51
Standards 139, 140
Standard Transmission Kit 2
Super Sealed Liquid Cells 88
Super ShakIR 100
T
Teflon Gaskets, Demountable Cell 87
Teflon Gaskets, Liquid Cell 87
Teflon O-Rings, Demountable Cell 87
Teflon O-Rings, Liquid Cell 87
Temperature Control, Diffuse 36
Temperature Control, HATR 20
Temperature Control, MIRacle 11
Temperature Control, Transmission 90, 92
TempPRO Software 90, 92, 108, 135
Terms and Conditions 157
TGA/FTIR Accessory 119
Theory, ATR 29
Theory, Diffuse Reflectance 41
Theory, Polarization 55
Theory, Specular Reflectance 51
Theory, Transmission 111
Thin Film Sampling 97
Trademarks 157
Transmission Auto Samplers 39, 81
Transmission Cells 87, 90
Transmission Cells, Heated 87, 90
Transmission Cells, NIR 92
Transmission Efficiency, Polarizers 54
Transmission Sampling Kits 2, 3, 4
Transmission Sampling, Gas 3, 107
Transmission Sampling Products 75
Transmission, Theory and Applications 111
Trough Plate, ATRMax 21, 23
Trough Plate, HATR 18, 19, 20
U
Ultima Sampling Kit 6
Universal Sample Holder 2, 3, 102, 112
UpIR, Diffuse Reflectance 37
UV-Vis 85Spec 132
UV-Vis Accessories 127
UV-Vis Cuvettes, Cells, Vials, and Holders 128
UV-Vis Microplate Reader 136
UV-Vis Polarizers 130
UV-Vis Spec 131
UV-Vis VeeMAX 133
V
Vacuum Pumps 96, 98
Valu-Line Reflectance Sampling Kit 5
Variable Angle ATR 21, 24, 28
Variable-Path Gas Cell 109
VATR 28
VeeMAX, ATR 24
VeeMAX, Motorized 24
VeeMAX, UV-Vis 133
VeeMAX, Variable Angle Specular 24, 44
Vertical Wafer Transmission Accessory 116
Vial Holder, UpIR 37
Vials 128
Vials, UpIR 37
Viewer Pressure Clamp, MIRacle 10
Volatiles Cover, ATRMax 23
Volatiles Cover, HATR 19, 20
Volatiles Cover, MIRacle 11
W
Wafer Holders 116, 118
Website, PIKE Technologies 157
Windows, Drilled 2, 3, 4, 105
Windows, Gas Cells 107, 108, 110
Windows, Liquid Cells 86, 87, 88, 89
Windows, Mull Cells 86, 102
Windows, Transmission 102
Windows, UpIR 37
Wire-Grid Polarizers 53
X
X, Y Autosampler 39, 85
X, Y Autosampler, Diffuse 39
X, Y Autosampler, Transmission 39, 85
XY, R-Theta and Y Autosampler for UV-Vis 137
Z
ZnS, Disks, Windows 88, 103, 104, 105
ZnS, Properties 113
ZnSe, ATRMax Crystal Plates 23
ZnSe, Disks, Windows 86, 87, 88, 91, 93,
103, 104, 105, 108, 110
ZnSe, HATR Crystal Plates 18, 19
ZnSe, MIRacle Crystal Plate 11
ZnSe, Properties 113
ZnSe, VeeMAX, ATR Crystal 24, 25, 26
13_Index 12-13-12_39131 107-122 12/13/12 1:38 PM Page 148
149
INDEX007-0200 PIKE TempPRO Software 135
007-0300 PIKECalc Software 26, 143
008-1000 to ATR Spectral Data Bases 144008-3026
008-4001 to Transmission Spectral Data Bases 145008-5021
010-10XX 10Spec – 10 Degree Specular Reflectance Accessory 49
010-3010 Specular Masks (3/8", 5/8" and 2") 45, 47
011-1000 30Spec – Specular Reflectance Accessory, 30 Degree 30, 46
011-2010 Sample Masks (3/8", 1/4", and 3/16") 46
011-4500 45Spec – Specular Reflectance Accessory, 45 Degree 46
012-10XX 80Spec – Specular Reflectance Accessory 47
012-11XX 80Spec – Specular Reflectance Accessory with Sample Masks (3/8", 5/8" & 2") 47
013-11XX VeeMAX III Variable Angle Specular Reflectance Accessory 26, 45
013-10XXX UV-Vis VeeMAX Variable Angle Specular Reflectance Accessory 133
013-2801 Motorized Upgrade for VeeMAX III 26, 45
013-2851 Motorized Option for VeeMAX III 26, 45
013-3101 VeeMAX III ATR Pressure Clamp 26
013-3110 ZnSe Crystal, 45° 26
013-3112 Ge Crystal, 45° 25
013-3114 Si Crystal, 45° 26
013-3115 ZnS Crystal, 45° 26
013-3130 ZnSe Crystal, 60° 26
013-3132 Ge Crystal, 60° 26
013-3134 Si Crystal, 60° 26
013-3135 ZnS Crystal, 45° 26
013-3300 Electrochemical Cell 26
013-3345 45° Crystal Holder 26
013-3360 60° Crystal Holder 26
013-3401 Liquids Retainer for VeeMAX III ATR Crystals 26
013-3501 VeeMAX III ATR Flow Cell
013-4010 Mask Set for VeeMAX 26
013-4015 Aperture Mask Set (7 mm, 13 mm, and 25 mm x 4 mm) 133
013-4021 Flat Plate, ZnSe, 45° 26
013-4031 Flat Plate, ZnSe, 60° 26
013-4041 Flat Plate, Ge, 45° 26
013-4051 Flat Plate, Ge, 60° 26
013-4061 Flat Plate, Ge, 65° 26
013-4071 Flat Plate, Si, 60° 26
013-4081 Flat Plate, Si, 45° 26
013-4091 Flat Plate, ZnS, 45° 26
013-4096 Flat Plate, ZnS, 60° 26
013-4121 Heated Flat Plate, ZnSe, 45° 26
013-4131 Heated Flat Plate, ZnSe, 60° 26
013-4141 Heated Flat Plate, Ge, 45° 26
013-4151 Heated Flat Plate, Ge, 60° 26
013-4161 Heated Flat Plate, Ge, 65° 26
013-4171 Heated Flat Plate, Si, 60° 26
013-4181 Heated Flat Plate, Si, 45° 26
013-4191 Heated Flat Plate, ZnS, 45° 26
013-4196 Heated Flat Plate, ZnS, 60° 26
013-4200 ATR Variable Angle Heating Conversion Plate 23
014-10XX Absolute Reflectance Accessory 50
015-10XX AGA – Grazing Angle Specular Reflectance Accessory 48
016-28XX MappIR Automated Wafer Accessory for 8" Wafers 118
016-30XX Purge Box for MappIR 118
017-28XX MAP300 Automated Wafer Accessory for 12" Wafers 118
017-30XX Purge Box for MAP300 118
017-3912 Additional 12" Wafer Mount (MAP300 only) 118
017-3980 Insert to Support 8" Wafer (MAP300 only) 118
020-19XX JetStream ATR Base Optics Accessory 27
020-2010 ZnSe Rod 27
020-2050 Ge Rod 27
020-3040 EPDM Crystal O-Rings 27
020-3041 EPDM Housing O-Rings 27
020-3045 Kalrez Crystal O-Rings 27
020-3046 Kalrez Housing O-Rings 27
021-19XX VATR Variable Angle, Vertical ATR 28
021-4000 KRS-5, 45° Parallelogram, 50 mm 28
021-4010 KRS-5, 60° Parallelogram, 50 mm 28
021-4020 KRS-5, 45° Parallelogram, 25 mm 28
021-4030 KRS-5, 60° Parallelogram, 25 mm 28
021-4040 ZnSe, 45° Parallelogram, 50 mm 28
021-4050 ZnSe, 45° Parallelogram, 25 mm 28
021-4060 Ge, 45° Parallelogram, 50 mm 28
021-4070 Ge, 60° Parallelogram, 50 mm 28
021-4080 Ge, 45° Parallelogram, 25 mm 28
021-4090 Ge, 60° Parallelogram, 25 mm 28
021-4100 Ge, 30° Parallelogram, 25 mm 28
021-4110 Si, 45° Parallelogram, 25 mm 28
021-4120 ZnSe, 60° Parallelogram, 25 mm 28
021-4130 Ge, 30° Parallelogram, 50 mm 28
021-4150 ZnSe, 60° Parallelogram, 50 mm 28
021-4160 Si, 45° Parallelogram, 50 mm 28
021-5020 VATR Crystal Holder, Clamp and Mirror, 25 mm 28
021-5030 Set of Pads, 25 mm and 50 mm 28
021-5040 VATR Crystal Holder and Clamp, 25 mm 28
021-5050 VATR Crystal Holder and Clamp, 50 mm 28
022-10XX HATR Trough Plate System with 45º ZnSe Crystal 19
022-11XX HATR Flat Plate System with 45º ZnSe Crystal 19
022-12XX HATR Combined Trough and Flat Plate System with 45º ZnSe Crystals 19
022-19XX HATR Platform Optics Assembly 19
022-2010-45 Trough Plate, ZnSe, 45º 19
022-2012-45 Trough Plate, ZnSe, 45°, 2 mm 19
022-2020-45 Flat Plate, ZnSe, 45º 19
022-2022-45 Flat Plate, ZnSe, 45°, 2 mm 19
022-2024-45 Sealed Flat Plate, ZnSe, 45° 19
022-2030-45 Trough Plate, KRS-5, 45º 19
022-2040-45 Flat Plate, KRS-5, 45º 19
022-2050-45 Trough Plate, Ge, 45º 19
022-2052-45 Trough Plate, Ge, 45°, 2 mm 19
022-2060-45 Flat Plate, Ge, 45º 19
022-2062-45 Flat Plate, Ge, 45°, 2 mm 19
022-2064-45 Sealed Flat Plate, Ge, 45° 19
022-2070-45 Trough Plate, AMTIR, 45º 19
022-2080-45 Flat Plate, AMTIR, 45º 19
022-2090-45 Trough Plate, Si, 45º 19
022-2100-45 Flat Plate, Si, 45º 19
022-2300 RCPlate for HATR (for 45° Crystals) 20
022-3040 Viton O-ring, HATR Flow Cell, Upper 20
022-3045 Viton O-ring, HATR Flow Cell, Lower 20
Part Number Index
13_Index 12-13-12_39131 107-122 12/13/12 1:38 PM Page 149
PIKETECHNOLOGIES
WWW.PIKETECH.COM
608-274-2721
150
022-3050 HATR (pivoting) Pressure Clamp 20
022-3051 HATR Volatiles Cover 20
022-3052 HATR Powder Press 20
022-3054 HATR High-Pressure Clamp 20
022-3110 Crystal, 45°, Trap, 80 x 10 x 4 mm ZnSe 20
022-3111 Crystal, 45°, Trap, 80 x 10 x 4 mm KRS-5 20
022-3112 Crystal, 45°, Trap, 80 x 10 x 4 mm Ge 20
022-3113 Crystal, 45°, Trap, 80 x 10 x 4 mm AMTIR 20
022-3114 Crystal, 45°, Trap, 80 x 10 x 4 mm Si 20
022-3130 Crystal, 60°, Trap, 80 x 10 x 4 mm ZnSe 20
022-3132 Crystal, 60°, Trap, 80 x 10 x 4 mm Ge 20
022-4010 HATR Flow Cell, ZnSe, 45° 20
022-4020 HATR Flow Cell, AMTIR, 45° 20
022-4030 HATR Flow Cell, KRS-5, 45° 20
022-4040 HATR Flow Cell, Si, 45° 20
022-4050 HATR Flow Cell, Ge, 45° 20
022-5110 HATR Heated Trough Plate, ZnSe, 45° 20
022-5120 HATR Heated Trough Plate, AMTIR, 45° 20
022-5130 HATR Heated Trough Plate, KRS-5, 45° 20
022-5140 HATR Heated Trough Plate, Si, 45° 20
022-5150 HATR Heated Trough Plate, Ge, 45° 20
022-5210 HATR Heated Flow-Through Cell, ZnSe, 45° 20
022-5220 HATR Heated Flow-Through Cell, AMTIR, 45° 20
022-5230 HATR Heated Flow-Through Cell, KRS-5, 45° 20
022-5240 HATR Heated Flow-Through Cell, Si, 45° 20
022-5250 HATR Heated Flow-Through Cell, Ge, 45° 20
022-5310 HATR Liquid Jacketed Trough Plate, ZnSe, 45° 20
022-5320 HATR Liquid Jacketed Trough Plate, AMTIR, 45° 20
022-5330 HATR Liquid Jacketed Trough Plate, KRS-5, 45° 20
022-5340 HATR Liquid Jacketed Trough Plate, Si, 45° 20
022-5350 HATR Liquid Jacketed Trough Plate, Ge, 45° 20
022-5410 HATR Liquid Jacketed Flow-Through Plate, ZnSe, 45° 20
022-5420 HATR Liquid Jacketed Flow-Through Plate, AMTIR, 45° 20
022-5430 HATR Liquid Jacketed Flow-Through Plate, KRS-5, 45° 20
022-5440 HATR Liquid Jacketed Flow-Through Plate, Si, 45° 20
022-5450 HATR Liquid Jacketed Flow-Through Plate, Ge, 45° 20
023-10XX ATRMax II Trough Plate System with 45º ZnSe Crystal 23
023-11XX ATRMax II Flat Plate System with 45º ZnSe Crystal 23
023-12XX ATRMax II Combined Trough & Flat Plate System with 45º ZnSe Crystals 23
023-19XX ATRMax II Variable Angle HATR 23
023-2001 Trough Plate, ZnSe, 45° 23
023-2002 Trough Plate, KRS-5, 45° 23
023-2003 Trough Plate, Ge, 45° 23
023-2011 Flat Plate, ZnSe, 45° 23
023-2012 Flat Plate, KRS-5, 45° 23
023-2013 Flat Plate, Ge, 45° 23
023-2021 Trough Plate, ZnSe, 30° 23
023-2022 Trough Plate, KRS-5, 30° 23
023-2023 Trough Plate, Ge, 30° 23
023-2031 Flat Plate, ZnSe, 30° 23
023-2032 Flat Plate, KRS-5, 30° 23
023-2033 Flat Plate, Ge, 30° 23
023-2041 Trough Plate, ZnSe, 60° 23
023-2042 Trough Plate, KRS-5, 60° 23
023-2043 Trough Plate, Ge, 60° 23
023-2044 Trough Plate, Si, 45° 23
023-2045 Flat Plate, Si, 45° 23
023-2046 Trough Plate, AMTIR, 45° 23
023-2047 Flat Plate, AMTIR, 45° 23
023-2051 Flat Plate, ZnSe, 60° 23
023-2052 Flat Plate, KRS-5, 60° 23
023-2053 Flat Plate, Ge, 60° 23
023-2300 RCPlate for ATRMax II 23
023-2800 Motorized Upgrade for ATRMax II 23
023-2850 Motorized Option for ATRMax II 23
023-3050 ATRMax Pressure Clamp 23
023-3051 ATRMax II Volatiles Cover 23
023-3052 ATRMax II Powder Press 23
023-3110 Crystal, 45°, Trap., 56 x 10 x 4, ZnSe 23
023-3112 Crystal, 45°, Trap., 56 x 10 x 4, Ge 23
023-3113 Crystal, 45°, Trap., 56 x 10 x 4, AMTIR 23
023-3114 Crystal, 45°, Trap., 56 x 10 x 4, Si 23
023-3120 Crystal, 30°, Trap., 56 x 10 x 4, Ge 23
023-3121 Crystal, 30°, Trap., 56 x 10 x 4, Si 23
023-3130 Crystal, 60°, Trap., 56 x 10 x 4, ZnSe 23
023-3132 Crystal, 60°, Trap., 56 x 10 x 4, Ge 23
023-3133 Crystal, 60°, Trap., 56 x 10 x 4, AMTIR 23
023-3134 Crystal, 60°, Trap., 56 x 10 x 4, Si 23
023-4000 ATRMax Flow Cell Assembly 23
023-4100 ATRMax Liquid-Jacketed Flow Cell Assembly 23
023-4200 ATRMax Heated Flow Cell Assembly 23
023-4300 ATRMax Heated Trough Plate Assembly 23
023-4400 ATRMax Heated Flat Plate Assembly 23
024-11XX HATRPlus Flat Plate System, with 45º ZnSe Crystal 19
024-19XX HATRPlus Platform Optics Assembly 19
024-3050 HATRPlus (pivoting) Pressure Clamp 20
024-3053 HATRPlus High-Pressure Clamp 20
025-18XX MIRacle ATR Base Optics/Platform Assembly 11
025-2018 ZnSe Performance Crystal Plate 11
025-2038 3 Reflection ZnSe Performance Crystal Plate 11
025-2058 Ge Performance Crystal Plate 11
025-2098 Si Performance Crystal Plate 11
025-2107 Diamond/ZnSeHS Performance Crystal Plate 11
025-2108 Diamond/ZnSe Performance Crystal Plate 11
025-2118 3 Reflection Diamond/ZnSe Crystal Plate 11
025-2208 Specular Reflection Performance Plate 11
025-3020 High-Pressure Clamp 11
025-3035 Confined Space Clamp 11
025-3050 Micrometric, Low-Pressure Clamp 11
025-3052 Flat Tip for Micrometric Clamp 11
025-3053 MIRacle Clamp Tip Assortment 11
025-3054 Concave Tip for Micrometric Clamp 11
025-3061 Swivel Tip for Micrometric Clamp 11
025-3092 Concave Tip for High-Pressure Clamps 11
025-3093 Swivel Tip for High-Pressure Clamps 11
025-3094 7.8 mm ATR Pressure Tip 11, 26
025-3095 Flat Tip for High-Pressure Clamps 11
025-3096 Sealed Pressure Tip for High-Pressure Clamp 11
025-4018 Heated ZnSe Performance Crystal Plate 11
025-4058 Heated Ge Performance Crystal Plate 11
025-4108 Heated Diamond/ZnSe Performance Crystal Plate, 60 °C max. 11
026-17XX GladiATR 300 Single Reflection ATR Base Optics 13
026-18XX GladiATR Single Reflection ATR Base Optics 13
026-19XX GladiATR Vision Base Optics 15
026-2001 GladiATR Standard Stainless Top 13
026-2002 GladiATR Heated Stainless Top 13
13_Index 12-13-12_39131 107-122 12/13/12 1:38 PM Page 150
151
INDEX
026-2003 GladiATR Liquid Jacketed Stainless Top 13
026-2004 GladiATR Vision Stainless Top 15
026-2005 GladiATR Vision Heated Stainless Top 15
026-2006 GladiATR Vision Liquid Jacketed Stainless Top 15
026-2050 Ge Crystal Plate (non-viewing) 13, 15, 16
026-2100 Diamond Crystal Plate 13
026-2102 GladiATR Vision Diamond Crystal Plate 15
026-2200 Specular Reflection Plate (non-viewing) 13, 15, 16
026-2202 Specular Reflection Plate (viewing) 15, 16
026-3020 High-Pressure Clamp 13, 15
026-3051 Volatiles Cover for Performance Plates 11, 13, 15, 16
026-4050 Heated Ge Crystal Plate, 130 °C (non-viewing) 13, 15, 16
026-4100 Heated Diamond Crystal Plate, 210 °C 13
026-4101 Heated Diamond Crystal Plate, 210 °C, (GladiATR Vision) 15
026-4102 Heated Diamond Crystal Plate, 300 °C 13
026-4110 Liquid Jacketed Diamond Crystal Plate 13
026-4112 Liquid Jacketed Diamond Crystal Plate (GladiATR Vision) 15
026-4150 Liquid Jacketed Ge Crystal Plate 13
026-5010 Liquids Retainer for Performance Plates, 260 °C 11, 15, 16
026-5012 Flow-Through Attachment, 210 °C 11, 13, 15, 16
026-5014 Flow-Through Attachment, 300 °C 13, 16
026-5013 Liquids Retainer and Volatiles Cover Set 11, 13, 15, 16
026-5015 Liquids Retainer and Volatiles Cover Set, 300 °C 13, 16
031-2010 X, Y, Z Adjustable Sample Position 79
031-2020 Non-Adjustable Sample Position 79
031-2030 Universal Spring Sample Holder 79
031-2040 Magnetic Sample Holder 79
031-2050 Micro KBr Pellet and Mull Holder 79
031-2070 Holder for Micro Diamond Cell 79
031-40XX 4X Beam Condenser 79
031-60XX 6X Beam Condenser 79
034-0090 µMAX IR Microscope Transmission Upgrade 74
034-20XX µMAX Sample Compartment IR Microscope for Transmission and Reflection 74
034-21XX Complete µMAX Sample Compartment IR Microscope with Transmission, Reflection, ATR and Video Camera 74
034-22XX µMAX Sample Compartment IR Microscope with Transmission, Reflection and ATR 74
034-3010 Video Camera for µMAX 74
034-3020 Binocular Viewer for µMAX 74
034-3030 Trinocular Viewer for µMAX 74
034-3040 RotATR, µMAX ATR, Ge Crystal 74
034-3060 Micro Compression Cell for 13 mm IR Transparent Windows 74, 76
034-3070 IR Microsampling Kit 74, 76
034-3080 Replacement Illumination Bulb for µMAX 74
034-40XX µMAX Sample Compartment IR Microscope for Reflection (ATR optional) 74
034-41XX Complete µMAX Sample Compartment IR Microscope for Reflection, ATR and Video Camera 74
034-42XX µMAX Sample Compartment IR Microscope with Reflection and ATR 74
041-10XX DiffusIR Accessory 36
041-60XX DiffusIR Accessory with Gold-Coated Optics 36
042-10XX EasiDiff Accessory with Sample Preparation Kit 32
042-2010 Small Sample Cup 34, 36, 38, 40
042-2020 Large Sample Cup 34, 36, 38, 40
042-2025 EasiDiff Sample Slide 34
042-3010 Abrasion Sampling Kit 34, 36, 38, 40
042-3020 Silicon Carbide Abrasive Disks 34, 36, 38, 40
042-3025 Diamond Abrasive Disks 34, 36, 38, 40
042-3030 Sample Cup Holder and Base 34, 38, 40
042-3035 Spatula – Spoon Style 2, 3, 4, 40, 101
042-3040 Sample Preparation Kit 34, 36, 40
042-3050 Spatula – Flat Style 2, 3, 4, 40, 101
042-3060 Abrasion Kit Disk Support Post/Flat Sample Post 34
042-3070 Camel Hair Brush 40
042-3080 Alignment Mirror 34, 36, 38, 40
042-3082 Alignment Mirror, Gold 34, 36, 38, 40
042-50XX EasiDiff Accessory, NIR Version with Gold-Coated Optics 34
043-0900 AutoDiff, 60 Position Sampling Tray 38
043-28XX AutoDiff – Automated Diffuse Reflectance System 38
043-3090 AutoDiff Set of 60 Sampling Cups, Large 38
043-78XX AutoDiff – Automated Diffuse Reflectance System, Gold-Coated Optics System 38
044-10XX UpIR – Out-of-Compartment Diffuse Reflectance Accessory 37
044-3010 Glass Vial Holder 37, 61
044-3020 Sample Vials with Threaded Caps, 21 x 70 mm 37
044-3030 Solids Sampling Insert 37
044-3040 Powders Sampling Insert 37
044-60XX UpIR – Out-of-Compartment Diffuse Reflectance Accessory with Gold-Coated Optics 37
045-10XX FlexIR NIR Fiber Optic Accessory 68
045-1100 Heated Liquid Sample Holder 69
045-1106 Sample Cups 69
045-2000 Liquids Sampling Tip for FlexIR, 1.5 mm pathlength 68
045-2001 Liquids Sampling Tip for FlexIR, 1.0 mm pathlength 68
045-2002 Liquids Sampling Tip for FlexIR, 2.0 mm pathlength 68
045-2010 Diffuse Reflectance Tip for FlexIR NIR Probe 68
045-30XX FlexIR Hollow Waveguide Base for MCT Version 67
045-3100 Narrow-band MCT Detector 67
045-3200 Mid-band MCT Detector 67
045-3400 Adjustable Probe Holder 67
045-3410 Standard Probe Holder 67
045-35XX FlexIR Hollow Waveguide Base for DTGS Version 67
045-4010 ZnSe ATR Probe, 1 m 67
045-4012 ZnSe ATR Probe, 2 m 67
045-4020 Diffuse Reflectance Probe, 1 m 67
045-4030 Specular Reflectance Probe, 1 m 67
045-4032 Specular Reflectance Probe, 2 m 67
045-4050 Ge ATR Probe, 1 m 67
045-4052 Ge ATR Probe, 2 m 67
045-4100 Diamond/ZnSe ATR Probe, 1 m 67
045-4102 Diamond/ZnSe ATR Probe, 2 m 67
045-4200 Diamond ATR Probe – Basic 67
045-4300 Diamond ATR Probe – High Temperature/High Pressure 67
045-5010 ZnSe ATR Probe, 1 m 67
045-5030 Specular Reflectance Probe, 1 m 67
045-5050 Ge ATR Probe, 1 m 67
045-5100 Diamond/ZnSe ATR Probe, 1 m 67
047-10XXX Microplate Reader Accessory 136
047-11XXX Transfer Optics Module 136
047-21XX X, Y Autosampler – Diffuse Reflectance Configuration 39, 85
047-22XX X, Y Autosampler – Diffuse Reflectance/Transmission Configuration 39, 85
047-3010 Photodiode Detector 136
047-3020 UV-Vis/NIR Optical Fiber Cable 136
047-61XX X, Y Autosampler – Diffuse Reflectance Configuration with Gold-Coated Optics 39, 85
047-62XX X, Y Autosampler – Diffuse Reflectance/Transmission Configuration with Gold-Coated Optics 39, 85
048-0060 Automated Transmission Tablet Analysis Stage for NIR IntegratIR 61
13_Index 12-13-12_39131 107-122 12/13/12 1:38 PM Page 151
PIKETECHNOLOGIES
WWW.PIKETECH.COM
608-274-2721
152
048-0108 Sample Plate with 18 x 2 mm ZnSe Window, Upward IntegratIR 59
048-0150 Rotating Stage for Petri Dish (for Heterogeneous Samples) 61
048-0151 Rotating Stage Adapter for 500 mL Beaker 61
048-0208 Sample Plate with 18 x 2 mm KBr Window, Upward IntegratIR 59
048-11XX Downward Sample Positioning Mid-Infrared IntegratIR 59
048-12XX 12 Degree Upward Sample Positioning Mid-Infrared IntegratIR 59
048-2020 Powder Sample Cup for Downward IntegratIR 59
048-2999 Glass Sample Vials, 19 x 65 mm 61
048-3000 Diffuse Gold Reference 59, 61
048-3001 Diffuse Gold Reference (Downward IntegratIR) 59
048-3070 NIST Traceable NIR Reference Standard 61, 142
048-3071 NIST Traceable NIR Reference Standard – Recertification 61, 142
048-3150 Narrow-band MCT Detector 59
048-3250 Mid-band MCT Detector 59
048-3350 Wide-Band MCT Detector 59
048-3450 DTGS Detector with Csl Detector Window 59
048-60XX NIR IntegratIR Integrating Sphere Accessory 61
050-10XX Valu-Line – FTIR Reflectance Accessories Kit 5
050-20XX Ultima Sampling Kit 6
073-16XX Vertical Wafer Accessory, Manual Version 116
073-26XX Vertical Wafer Accessory, Automated Version 116
073-3600 6" Wafer Mount, Blank 116
073-3620 Insert to Support 2" Wafer 116
073-3630 Insert to Support 3" Wafer 116
073-3640 Insert to Support 4" Wafer 116
073-3650 Insert to Support 5" Wafer 116
073-3660 Additional Wafer Mount 116
073-3800 Blank Support – for Custom Wafers (MappIR only) 118
073-3820 Insert to Support 2" Wafer 118
073-3830 Insert to Support 3" Wafer 118
073-3840 Insert to Support 4" Wafer 118
073-3850 Insert to Support 5" Wafer 118
073-3860 Insert to Support 6" Wafer 118
073-3880 Additional 8" Wafer Mount (MappIR only) 118
073-9110 96-Well Diffuse Reflectance Sampling Plate 39, 85
073-9130 96-Well Transmission Sampling Plate 39, 85
074-26XX Automated Transmission Multi-SamplIR for FTIR 82
074-3661 Additional Standard Sampling Plate 82
075-28XX Automated 8" Horizontal Transmission Accessory 84
075-3881 Additional Sampling Plate for 8" Automated HorizontalTransmission Accessory 84
076-1120 Dual Digital Temperature Control Module 120
076-1130 4 Zone Digital Temperature Control Module for Shimadzu TGA 120
076-1210 Digital Temperature Control Module, 300 °C 13, 94, 108
076-1220 Digital Temperature Control Module 11, 13, 15, 16, 20, 23, 26, 97
076-1230 Digital Temperature Control Module for Falcon Accessory 90, 92, 134
076-1240 Heated Gas Cell Temperature Controller 110
076-1250 Peltier Control Unit 135
076-1410 Digital Temperature Control Module, PC Control, 300 °C 13, 94, 108
076-1420 Digital Temperature Control Module, PC Control 11, 13, 16, 20, 23, 26
076-1430 Digital Temperature Control Module, PC Control for Falcon Accessory 90, 92 134
076-1450 USB Peltier Control Unit 135
076-2220 Digital Temperature Control Module, HTV Chambers 36
076-2230 Digital Temperature Control Module, LTV Chamber 36
076-2240 S85 Digital Temperature Controller 75
076-2420 PC Controlled Temperature Module, HTV Chambers 36
076-2430 PC Controlled Temperature Module, LTV Chamber 36
076-2440 S84 Digital Temperature Controller – PC Control 75
076-28XX Automated 12" Horizontal Transmission Accessory 84
076-3881 Additional Sampling Plate for 12" Automated HorizontalTransmission Accessory 84
076-6025 Digital Force Adapter for High-Pressure Clamp 11, 16
090-1000 Manual Polarizer, ZnSe 23, 26, 45, 47, 48, 54
090-1200 Manual Polarizer, KRS-5 26, 45, 47, 48, 54
090-1300 Manual Polarizer, CaF2 54
090-1400 Manual Polarizer, BaF2 54
090-1500 Manual Polarizer, Ge 54
090-1600 Manual Polarizer, Polyethylene 54
090-2000 Automated Polarizer, ZnSe 23, 54
090-2200 Automated Polarizer, KRS-5 54
090-2300 Automated Polarizer, CaF2 54
090-2400 Automated Polarizer, BaF2 54
090-2500 Automated Polarizer, Ge 54
090-2600 Automated Polarizer, Polyethylene 54
090-3000 Precision Manual Polarizer, ZnSe 26, 45, 54
090-3200 Precision Manual Polarizer, KRS-5 26, 45, 54
090-3300 Precision Manual Polarizer, CaF2 54
090-3400 Precision Manual Polarizer, BaF2 54
090-3500 Precision Manual Polarizer, Ge 54
090-3600 Precision Manual Polarizer, Polyethylene 54
090-4000 Precision Manual Polarizer, ZnSe 26, 45, 54
090-4200 Precision Manual Polarizer, KRS-5 26, 45, 54
090-4300 Precision Manual Polarizer, CaF2 54
090-4400 Precision Manual Polarizer, BaF2 54
090-4500 Precision Manual Polarizer, Ge 54
090-4600 Precision Manual Polarizer, Polyethylene 54
091-20XX RotatIR Automated Rotating Sample Stage 83
110-50XXX Single Position Cuvette Holder – Air-Cooled 135
110-60XX NIR Falcon Base 92
110-60XXX UV-Vis Falcon Base 134
110-70XXX Single Position Cuvette Holder – Liquid-Cooled 135
111-3610 5 mm Vial Holder 92, 134
111-3620 8 mm Vial Holder 92, 134
111-3630 12 mm Vial Holder 92, 134
111-3640 10 mm Cuvette Holder, Falcon 92, 134
111-3650 10 mm Cuvette Holder 129
111-3660 10–100 mm Adjustable Cuvette Holder 129
111-40XX Mid-IR Falcon Base with Cell Holder 90
112-1000 Heated Solid Transmission Accessory 94
112-2010 12–15 mm Diameter Sample Holder 94
112-2020 16–20 mm Diameter Sample Holder 94
112-2030 21–25 mm Diameter Sample Holder 94
112-2040 26–30 mm Diameter Sample Holder 94
115-0001 Heated Transfer Line for Shimadzu TGA 120
115-0005 Heated Transfer Line for Mettler 851 TGA 120
115-0006 Heated Transfer Line for Mettler 851e/LF or TGA-DSC1 120
115-0007 Heated Transfer Line for TA Instruments Q600 TGA 120
115-0008 Heated Transfer Line for TA Instruments Q5000R TGA 120
115-0009 Heated Transfer Line for TA Instruments Q50/Q500 TGA 120
115-0010 Heated Transfer Line for TA Instruments 2050 TGA 120
115-0011 Heated Transfer Line for Netzsch TGA 120
115-0012 Heated Transfer Line for PESTA6/4000 110V TGA 120
115-0013 Heated Transfer Line for SETARAM 120
115-0014 Heated Transfer Line for PESTA6/4000 220V TGA 120
115-0050 GC-FTIR Accessory Transfer Line 121
121-0500 Aperture Mask, 4 x 7 mm 131
121-0501 Aperture Mask, 35 x 3 mm 132
13_Index 12-13-12_39131 107-122 12/13/12 1:38 PM Page 152
153
INDEX
121-1500 UV-Vis 15Spec 131
121-2000 UV-Vis 20Spec 131
121-3000 UV-Vis 30Spec 131
121-4500 UV-Vis 45Spec 131
121-6000 UV-Vis 60Spec 131
121-85XXX UV-Vis 85Spec – Specular Reflectance Accessory 132
140-10XXR GC-FTIR Accessory, Right Side 121
140-10XXL GC-FTIR Accessory, Left Side 121
140-2001 GC Graphite Window Gasket 121
140-2010 Ferrule for 0.25 mm Coupling 121
140-2015 Ferrule for 0.32 mm Coupling 121
140-2020 Ferrule for 0.53 mm Coupling 121
155-10XXL External Sample Module, Left Side 122
155-10XXR External Sample Module, Right Side 122
155-2010 DLaTGS Detector for External Sample Module 122
155-2020 MCT Detector (mid band) for External Sample Module 122
160-1001 13 x 2 mm ZnSe (6 pack) 103
160-1002 25 x 2 mm CaF2 (6 pack) 103
160-1003 25 x 5 mm KBr (6 pack) 104
160-1004 25 x 2 mm NaCl (6 pack) 103
160-1005 13 x 2 mm NaCl (6 pack) 103
160-1006 38 x 19 x 4 mm NaCl (6 pack) 105
160-1007 25 x 2 mm ZnSe (6 pack) 103
160-1008 13 x 2 mm KBr (6 pack) 76, 103, 121
160-1009 25 x 4 mm KBr (6 pack) 104
160-1010 32 x 3 mm KBr (6 pack) 2, 3, 4, 104
160-1011 25 x 5 mm NaCl (6 pack) 104
160-1012 25 x 4 mm NaCl (6 pack) 104
160-1013 32 x 3 mm NaCl (6 pack) 104
160-1014 32 x 3 mm NaCl, Drilled (6 pack) 104
160-1015 32 x 3 mm KBr, Drilled (6 pack) 2, 3, 4, 104
160-1109 25 x 4 mm Double Anti-Reflective Coated ZnSe 104, 110
160-1110 25 x 4 mm Single Anti-Reflective Coated ZnSe 104, 110
160-1111 41 x 23 x 3 mm ZnSe 105
160-1112 32 x 3 mm ZnSe, Drilled 87, 91, 104
160-1113 32 x 3 mm ZnSe 36, 86, 87, 91, 104
160-1114 25 x 4 mm ZnSe 86, 93, 104, 107, 110
160-1115 13 x 2 mm ZnSe 103
160-1116 25 x 4 mm Si 86, 104
160-1117 25 x 2 mm Si 103
160-1118 20 x 2 mm Si 103
160-1119 41 x 23 x 6 mm NaCl, Drilled 105
160-1120 41 x 23 x 6 mm NaCl 105
160-1121 32 x 3 mm NaCl, Drilled 87, 91, 104
160-1122 32 x 3 mm NaCl, Plain 86, 87, 91, 104
160-1123 25 x 5 mm NaCl 104
160-1124 25 x 4 mm NaCl 86, 104, 107, 110
160-1125 32 x 3 mm KRS-5, Drilled 87, 91, 104
160-1126 32 x 3 mm KRS-5, Plain 86, 87, 91, 93, 104
160-1127 25 x 4 mm KRS-5 86, 104, 110
160-1128 20 x 2 mm KRS-5 103
160-1129 38 x 19 x 4 mm KBr, Drilled 105
160-1130 38 x 19 x 4 mm KBr 105
160-1131 KBr, 32 x 3 mm, Drilled 87, 91, 104
160-1132 KBr, 32 x 3 mm, Plain 36, 86, 87, 91, 93, 104
160-1133 KBr, 25 x 4 mm 4, 86, 93, 104, 107, 110
160-1134 20 x 2 mm KBr 75, 103
160-1135 13 x 2 mm KBr Window 74, 76, 103, 121
160-1136 32 x 3 mm Ge, Drilled 87, 91, 104
160-1137 32 x 3 mm Ge, Plain 86, 87, 91, 104
160-1138 25 x 4 mm Ge 86, 104
160-1139 20 x 2 mm Ge 103
160-1140 38 x 19 x 4 mm CaF2, Drilled 105
160-1141 38 x 19 x 4 mm CaF2 105
160-1142 32 x 3mm CaF2, Drilled 87, 91, 104
160-1143 32 x 3 mm CaF2, Plain 86, 87, 91, 104
160-1144 20 x 2 CaF2 26, 75, 103
160-1145 38 x 19 x 4 mm BaF2, Drilled 105
160-1146 32 x 3 mm BaF2, Drilled 87, 91, 104
160-1147 32 x 3 mm BaF2, Plain 86, 87, 91, 104
160-1148 20 x 2 mm BaF2 75, 103
160-1149 13 x 1 mm BaF2 75, 103
160-1150 38 x 19 x 2 mm ZnSe, Drilled 105
160-1151 38 x 19 x 2 mm ZnSe 105
160-1152 50 x 3 mm ZnSe 105
160-1153 49 x 3 mm ZnSe 105
160-1154 25 x 5 mm ZnSe 104
160-1155 25 x 2 mm ZnSe 37, 103
160-1156 38 x 19 x 2 mm Si, Drilled 105
160-1157 38 x 19 x 2 mm Si 105
160-1158 32 x 3 mm Si, Drilled 87, 91, 104
160-1159 32 x 3 mm Si 36, 86, 87, 91, 104
160-1160 13 x 2 mm Si 103
160-1161 38 x 19 x 4 mm NaCl, Drilled 105
160-1162 38 x 19 x 4 mm NaCl 105
160-1163 29 x 14 x 4 mm NaCl, Drilled 105
160-1164 29 x 14 x 4 mm NaCl 105
160-1165 50 x 3 mm NaCl 105
160-1166 49 x 6 mm NaCl 105
160-1167 41 x 3 mm NaCl 105
160-1168 25 x 2 mm NaCl 103
160-1169 20 x 2 mm NaCl 103
160-1170 13 x 2 mm NaCl 103
160-1171 50 x 3 mm KRS-5 105
160-1172 25 x 2 mm KRS-5 103
160-1173 13 x 2 mm KRS-5 103
160-1178 37.5 x 4 mm KCl 110
160-1182 41 x 23 x 6 mm KBr, Drilled 105
160-1183 41 x 23 x 6 mm KBr 105
160-1184 29 x 14 x 4 mm KBr, Drilled 105
160-1185 29 x 14 x 4 mm KBr 105
160-1186 50 x 3 mm KBr 105
160-1187 49 x 6 mm KBr 105
160-1188 41 x 3 mm KBr 105
160-1189 25 x 5 mm KBr 104
160-1190 38 x 19 x 4 mm Ge 105
160-1191 13 x 2 mm Ge 103
160-1192 38 x 19 x 4 mm CsI, Drilled 105
160-1193 38 x 19 x 4 mm CsI 105
160-1194 32 x 3 mm CsI, Drilled 104
160-1195 32 x 3 mm CsI 104
160-1196 25 x 4 mm CsI 104
160-1197 20 x 2 mm CsI 103
160-1198 13 x 2 mm CsI 103
160-1199 32 x 3 mm AMTIR, Drilled 104
160-1200 32 x 3 mm AMTIR 104
160-1201 25 x 2 mm AMTIR 37, 103
160-1207 29 x 14 x 4 mm CaF2 105
13_Index 12-13-12_39131 107-122 12/13/12 1:38 PM Page 153
PIKETECHNOLOGIES
WWW.PIKETECH.COM
608-274-2721
154
160-1208 50 x 3 mm CaF2 105
160-1209 41 x 3 mm CaF2 105
160-1210 25 x 5 mm CaF2 104
160-1211 25 x 4 mm CaF2 86, 104, 107, 110
160-1212 25 x 2 mm CaF2 103
160-1213 13 x 2 mm CaF2 103
160-1214 38 x 19 x 4 mm BaF2 105
160-1215 29 x 14 x 4 mm BaF2 105
160-1216 41 x 3 mm BaF2 105
160-1217 25 x 4 mm BaF2 86, 104, 107, 110
160-1218 13 x 2 mm BaF2 103
160-1233 38 x 3 mm SiO2 104
160-1241 13 x 2 mm ZnS 103
160-1269 38 x 19 x 2 mm AMTIR 105
160-1270 38 x 19 x 2 mm AMTIR, Drilled 105
160-1275 38 x 19 x 2 mm ZnS 105
160-1276 38 x 19 x 2 mm ZnS, Drilled 105
160-1277 41 x 23 x 3 mm ZnS 105
160-1279 41 x 23 x 3 mm ZnS, Drilled 105
160-1280 41 x 23 x 3 mm ZnSe, Drilled 105
160-1286 37.5 x 4 mm Single AR Coated ZnSe 104, 110
160-1287 37.5 x 4 mm CaF2 104, 110
160-1288 37.5 x 4 mm KBr 104, 110
160-1289 25 x 4 mm KCl 104, 110
160-1290 37.5 x 4 mm NaCl 104, 110
160-1291 37.5 x 4 mm ZnSe 104, 110
160-1292 38 x 19 x 4 mm SiO2 105
160-1293 38 x 19 x 4 mm SiO2, Drilled 105
160-1301 13 x 2 mm AMTIR 103
160-1304 20 x 2 mm ZnSe 26, 103
160-1305 25 x 2 mm KBr 103
160-1306 25 x 2 mm BaF2 103
160-1307 25 x 2 mm Ge 37, 103
160-1308 25 x 2 mm CsI 103
160-1311 25 x 5 mm BaF2 104
160-1312 25 x 5 mm KRS-5 93, 104
160-1313 25 x 5 mm Ge 104
160-1315 38 x 3 mm ZnS 104
160-1316 25 x 5 mm CsI 104
160-1320 38 x 6 mm KBr 3, 104, 107, 108, 120
160-1321 38 x 6 mm NaCl 104, 107
160-1322 38 x 6 mm BaF2 104, 107, 108
160-1323 38 x 6 mm Ge 104
160-1324 38 x 6 mm Si 104
160-1326 38 x 6 mm CsI 104
160-1329 38 x 6 mm ZnSe 104, 107, 108, 120
160-1341 41 x 3 mm ZnSe 105
160-1342 38 x 6 mm CaF2 104, 107
160-1343 38 x 6 mm KRS-5 104, 108
160-1344 38 x 3 mm KRS-5 104
160-1349 38 x 3 mm BaF2 104
160-1350 38 x 3 mm Ge 104
160-1353 38 x 3 mm Si 104
160-1355 38 x 6 mm SiO2 104
160-1357 38 x 6 mm AMTIR 104
160-5000 25 x 2 mm Sapphire 37
160-5001 13 x 1 mm CaF2 75, 103
160-5003 13 x 1 mm KBr 75, 103
160-5004 13 x 1 mm NaCl 103
160-5007 29 x 14 x 4 mm Ge 105
160-5009 29 x 14 x 4 mm KRS-5 105
160-5010 29 x 14 x 4 mm BaF2, Drilled 105
160-5011 29 x 14 x 4 mm CaF2, Drilled 105
160-5012 29 x 14 x 4 mm Ge, Drilled 105
160-5014 29 x 14 x 4 mm KRS-5, Drilled 105
160-5016 38 x 19 x 4 mm KRS-5, Drilled 105
160-5025 38 x 3 mm ZnSe 104
160-5027 49 x 6 mm BaF2 105
160-5029 49 x 6 mm CsI 105
160-5030 50 x 3 mm BaF2 105
160-5031 38 x 19 x 4 mm KRS-5 105
160-5032 38 x 19 x 4 mm Ge, Drilled 105
160-5047 32 x 3 mm ZnS 104
160-5048 32 x 3 mm ZnS, Drilled 104
160-5049 32 x 3 mm SiO2 Disk 36, 104
160-5052 32 x 3 mm SiO2, Drilled 104
160-5084 25 x 2 mm ZnS 103
160-5086 25 x 2 mm SiO2 103
160-5087 25 x 4 mm ZnS 104
160-5089 25 x 4 mm SiO2 104
160-5090 25 x 5 mm ZnS 104
160-5100 25 x 5 mm SiO2 104
160-5118 20 x 2 mm ZnS 103
160-5119 20 x 2 mm SiO2 103
160-5120 13 x 2 mm SiO2, low OH 103
160-5121 20 x 2 mm SiO2, low OH 103
160-5122 25 x 2 mm SiO2, low OH 103
160-5123 25 x 4 mm SiO2, low OH 104
160-5124 25 x 5 mm SiO2, low OH 104
160-5125 32 x 3 mm SiO2, low OH 36, 104
160-5126 32 x 3 mm SiO2, low OH, Drilled 104
160-5127 38 x 3 mm SiO2, low OH 104
160-5128 38 x 6 mm SiO2, low OH 104
160-5029 49 x 6 mm SiO2, low OH 105
160-5130 38 x 19 x 4 mm SiO2, low OH 105
160-5131 38 x 19 x 4 mm SiO2, low OH, Drilled 105
160-5146 41 x 23 x 6 mm BaF2 105
160-5147 41 x 23 x 6 mm CaF2 105
160-5152 41 x 23 x 6 mm BaF2, Drilled 105
160-5153 41 x 23 x 6 mm BaF2, Drilled 105
160-5157 41 x 3 mm ZnS 105
160-5161 49 x 3 mm ZnS 105
160-5164 49 x 6 mm SiO2 105
160-5173 50 x 3 mm CsI 105
160-5177 50 x 3 mm ZnS 105
160-5201 13 x 2 mm SiO2 103
160-5205 49 x 6 mm KRS-5 105
160-5206 49 x 6 mm CaF2 105
160-5211 20 x 2 mm Polyethylene 103
160-5213 25 x 2 mm Polyethylene 103
160-5214 25 x 4 mm Polyethylene 86, 93, 104
160-5215 32 x 3 mm Polyethylene, Drilled 87, 104
160-5216 32 x 3 mm Polyethylene 86, 87, 93, 104
160-5217 41 x 3 mm Polyethylene 105
13_Index 12-13-12_39131 107-122 12/13/12 1:38 PM Page 154
155
INDEX
160-5218 38 x 3 mm Polyethylene 104
160-5219 38 x 6 mm Polyethylene 104
160-5220 38 x 3 mm KBr 104
160-8010 KBr Powder, 100 g 2, 3, 4, 34, 36, 40, 95, 96, 98, 99, 100, 101, 103
160-8015 KBr Chunks, 100 g 101, 103
161-0500 Nujol, 1 0z. 2, 3, 4, 101
161-0510 Fluorolube, 1 0z. 2, 3, 4, 101
161-0520 Glass Syringe, 1 mL 87, 88, 91
161-0521 Glass Syringe, 2 mL 2, 3, 4, 87, 88, 91
161-0522 Glass Syringe, 5 mL 87, 88, 91
161-1010 7 mm Die Set 2, 3, 95
161-1018 KBr Single Pellet Holder 2, 3, 95, 102
161-1024 3 mm Die Set 95
161-1027 PIKE Hand Press Body 2, 3, 95
161-1028 1 mm Die Set 95
161-1035 ShakIR Stainless Steel Vial with Ball, 1" long 100
161-1037 Stainless Steel Ball 100
161-1038 Bullet-Shaped Bead 100
161-1039 Super ShakIR Stainless Steel Vial with Ball, 1.7" long 100
161-1041 Stainless Steel Ball Assortment 100
161-1070 ShakIR, Heavy Duty Sample Grinder 100
161-1080 Super ShakIR Sample Grinder 100
161-1100 Hand Press for 7 mm, 3 mm, and 1 mm pellets 95
161-1900 Evacuable Pellet Press for 13 mm pellets 96, 98, 99
161-1903 Anvils for Evacuable Pellet Press 96
161-1906 Piston O-Rings 96
161-1907 Base O-Rings 96
161-1908 Pellet Extracting Tool 96
161-2500 Bolt Press (for KBr pellets) 4, 95
161-2511 Wrench Set for Bolt Press 4, 95
161-2520 Bolt Press Holder 95, 102
161-2530 Slide Sample Holder, Quartz/Cylindrical Cell, 10–20 mm 89, 129
161-2540 Slide Sample Holder, Quartz/Cylindrical Cell, 50 mm 89, 129
161-2550 Slide Sample Holder, Quartz/Cylindrical Cell, 100 mm 89, 129
161-3500 Hydraulic Die for 13 mm pellets 95
161-5035 35 mm Agate Mortar and Pestle 4, 101
161-5040 40 mm Agate Mortar and Pestle 101
161-5050 50 mm Agate Mortar and Pestle 2, 3, 95, 96, 98, 99, 101
161-5065 65 mm Agate Mortar and Pestle 101
161-5095 95 mm Agate Mortar and Pestle 101
161-5100 100 mm Agate Mortar and Pestle 101
161-5700 Dual Pellet Holder for 7 mm, 3 mm, and 1 mm pellets 95, 102
161-6000 Finger Cots 2, 3, 4
162-0010 Micro Diamond Cell, 1.6 mm 74, 77, 79
162-0020 Micro Diamond Cell, 2.0 mm 74, 77, 79
162-0030 Micro Plane with Carbide Blade 74, 76
162-0040 Micro Plane with Diamond Blade 74, 76
162-0205 5 mm Disposable Glass Vials, 6 mm x 50 mm 92, 129
162-0208 8 mm Glass Vials 92, 129
162-0212 12 mm Glass Vials 92, 129
162-0220 to Standard Rectangular Cuvettes 128162-0267
162-0268 to Semi-micro Rectangular Cuvettes – 4 mm Opening 128162-0307
162-0308 to Micro Rectangular Cuvettes – 2 mm Opening 128162-0347
162-0348 Polystyrene, Disposable Cuvettes 129
162-0349 Polystyrene, Semi-micro Disposable Cuvettes 129
162-1000 Standard Transmission Sampling Kit (STS) – Solids and Liquids 2
162-1100 Demountable Liquid Cell Assembly/Holder 2, 3, 4, 87
162-1104 Demountable Liquid Cell Needle Plate 87, 91
162-1110 to Press-On Demountable Liquid Cell Spacers, 25 mm 86, 93162-1190
162-1201 Spacer for 1 mm Pathlength Cuvette 117, 122
162-1202 Spacer for 2 mm Pathlength Cuvette 117, 122
162-1205 Spacer for 5 mm Pathlength Cuvette 117, 122
162-1210 to Demountable Liquid Cell Spacers, 32 mm 86, 87, 91162-1290
162-1300 Teflon Stoppers for Needle Plate 87, 88, 91
162-1310 Teflon Gaskets 87
162-1320 Teflon O-Rings 87
162-1330 Viton O-Rings, 32 mm 86
162-1600 Demountable Liquid Cell for the mid-IR Falcon Accessory 91
162-1601 to Super-Sealed Liquid Cells 88162-1689
162-1801 Long-Path Quartz Cell, 10 mm 89, 129
162-1802 Long-Path Quartz Cell, 20 mm 89, 129
162-1805 Long-Path Quartz Cell, 50 mm 89, 129
162-1810 Long-Path Quartz Cell, 100 mm 89, 129
162-1831 Cylindrical Cells with Teflon Stoppers, Optical Glass, 10 mm 129
162-1832 Cylindrical Cells with Teflon Stoppers, Optical Glass, 20 mm 129
162-1835 Cylindrical Cells with Teflon Stoppers, Optical Glass, 50 mm 129
162-1840 Cylindrical Cells with Teflon Stoppers, Optical Glass, 100 mm 129
162-1841 Cylindrical Cells with Teflon Stoppers, Far UV Quartz, 10 mm 129
162-1842 Cylindrical Cells with Teflon Stoppers, Far UV Quartz, 20 mm 129
162-1845 Cylindrical Cells with Teflon Stoppers, Far UV Quartz, 50 mm 129
162-1850 Cylindrical Cells with Teflon Stoppers, Far UV Quartz, 100 mm 129
162-1900 RTD Probe 135
162-1905 Magnetic Stirring Bar, 5 mm 135
162-2000 Comprehensive Transmission Sampling Kit (CTS) 3
162-2001 High Temperature Purge Tubes for Heated Gas Flow Cell 102, 108
162-2009 Viton O-Rings, 200 ºC max. 108
162-20XX Heated Gas Flow Cell 108
162-2100 Short-Path EC Gas Cell, 100 mm 4, 107
162-2101 EC Gas Cell Glass Body, 100 mm 107
162-2102 EC Gas Cell Window Cap 107
162-2105 EC Gas Cell Holder, 100 mm 107
162-2106 Septum Cap 107
162-2109 EC Viton O-Rings 107
162-2115 EC Gas Cell Holder, 50 mm 102
162-2150 EC Gas Cell, 50 mm 107
162-2155 EC Gas Cell Glass Body, 50 mm 107
162-2200 HT Gas Cell, 100 mm 3, 107
162-2201 HT Glass Body, 100 mm 107
162-2202 HT Cell Window Cap 107
162-2205 HT Gas Cell Holder, 100 mm 102, 107
162-2209 HT Viton O-Rings 107
162-2215 Gas Cell Holder, 50 mm 102
162-2250 HT Gas Cell, 50 mm 107
162-2255 HT Glass Body, 50 mm 107
162-2309 High Temperature O-Rings, 325 ºC max. 108, 120
162-24XX TGA/FTIR Accessory Flow Cell 112
162-3000 Educational Transmission Sampling Kit (ETS) 4
162-3600 Press-On Demountable Liquid Cell Holder, 25 mm 86, 102
162-3610 Press-On Demountable Liquid Cell Holder, 32 mm 2, 3, 4, 86, 102
162-3621 Viton® O-Rings, 25 mm 86
13_Index 12-13-12_39131 107-122 12/13/12 1:38 PM Page 155
PIKETECHNOLOGIES
WWW.PIKETECH.COM
608-274-2721
156
162-4000 Crystal Polishing Kit 106
162-4010 Glass Plate 106
162-4011 Polishing Pads 106
162-4012 Grinding Compound, 400 grit 106
162-4013 Grinding Compound, 600 grit 106
162-4014 Polishing Compound 106
162-4015 Camel Hair Brush 106
162-4105 Plate for Motorized Microscope Stage 75
162-4106 2" x 3" Slide Mount for Transmission Measurements 75
162-4107 Holder for 1, 2, 3, mm Diameter Samples 75
162-4108 Window Mount, 32 x 3 mm 75
162-4109 Gas Valve 1/16", Gas Connection 75
162-4110 Quick Connector 75
162-4111 Reference Mirror, 13 x 1 mm 75
162-4140 DiffusIR Environmental Chamber (LTV), -150 to 500 °C 36
162-4150 DiffusIR Environmental Chamber (HTV), Ambient to 500 °C 36
162-4160 Liquid Nitrogen Cooled System and Temperature Control Module DiffusIR Environmental Chamber (LTV), -150 to 500 °C 36
162-4180 High-Pressure Adaptation for Heated Chambers (HTV) 36
162-4184 S84 Microscope Heat Stage 75
162-4190 DiffusIR Environmental Chamber (HTV), Ambient to 900 °C 36
162-43XX Cryostat190 93
162-4210 O-Ring, DiffusIR Chamber 36
162-4215 O-Ring, DiffusIR Chamber Cooling Line 36
162-4251 Ceramic Cup, DiffusIR Chamber, Porous 36
162-4270 Alignment Mirror, DiffusIR Chamber 36
162-4301 Cryostat190 Liquid Transmission Holder 93
162-4302 Cryostat190 Solid Transmission Holder 93
162-4303 Rotary Pump for Vacuum Insulation 93
162-4304 O-Ring for Liquid Cell 93
162-5300 Magnetic Film Holder 2, 3, 4, 96, 97, 98, 99, 102
162-5400 Film Sampling Card, 20 mm, Clear Aperture 2, 3,4, 83, 102
162-5410 Sampling Card for 13 mm Pellets 96, 98, 99, 102
162-5420 1.5 mil Polystyrene Reference Standard 140
162-5440 55 micron Polystyrene Reference Standard 140
162-5450 1.5 mil NIST Traceable Polystyrene Reference Standard 140
162-5460 Specular Reflectance Standard 50, 140
162-5470 ATR Reference Standard 142
162-5475 ATR Reference Standard with Recommended Validation Procedure 142
162-5476 ATR Reference Standard, Recertification 142
162-5480 Diffuse PTFE Reference, 0.9" Optical Diameter 141
162-5481 Diffuse Gold Reference, 0.9" Optical Diameter 141
162-5482 Diffuse Gold Reference, 1.7" Optical Diameter 141
162-5485 MidIR Diffuse Reflectance Wavelength Standard 141
162-5486 MidIR Diffuse Reflectance Wavelength, Recertification 141
162-5500 Heavy-Duty Magnetic Film Holder 102
162-5600 Universal Sample Holder, 20 mm Aperture 2, 3, 102
162-5610 Universal Sample Holder, 10 mm Aperture 102
162-5611 25 mm O-Rings for Universal Sample Holder 102
162-5612 10 mm O-Rings for Universal Sample Holder 102
162-6401 3-position Sample Slide for 13 mm Windows 74, 76
163-10XX 10 m Metal Gas Cell 110
163-11XX 10 m Glass Gas Cell 110
163-12XX 2.4 m Metal Gas Cell 110
163-15XX 5 m Metal Gas Cell 110
163-16XX 1-16v m Glass Gas Cell 110
163-20XX 20 m Glass Gas Cell 110
163-40XX 10 m Heated Metal Gas Cell, 115 V 110
163-40XX-30 10 m Heated Metal Gas Cell, 230 V 110
163-41XX 10 m Heated Glass Gas Cell, 115 V 110
163-41XX-30 10 m Heated Glass Gas Cell, 230 V 110
163-42XX 2.4 m Heated Metal Gas Cell, 115 V 110
163-42XX-30 2.4 m Heated Metal Gas Cell, 230 V 110
163-43XX 20 m Heated Glass Gas Cell, 230 V 110
163-43XX-30 20 m Heated Glass Gas Cell, 230 V 110
163-45XX 5 m Heated Metal Gas Cell, 115 V 110
163-45XX-30 5 m Heated Metal Gas Cell, 230 V 110
163-46XX 1–16v Heated Glass Gas Cell, 115 V 110
163-46XX-30 1–16v Heated Glass Gas Cell, 230 V 110
170-1000 Liquid Recirculator 36, 75, 90, 92, 94, 134, 135
180-10xx Photoacoustic Accessory – Gas Analysis – PA 101 124
180-11xx Photoacoustic Accessory – PA 301 124
180-2010 Gas Flow Meter 124
180-2011 PAS301 Carbon Black Reference 124
180-2012 PAS Sample Cups, Small 124
180-2013 PAS Sample Cups, Large 124
180-2014 KBr, 19 x 2 mm 124
180-2015 BaF2, 19 x 2 mm 124
180-2016 Si, 19 x 2 mm 124
180-2017 Quartz, 19 x 2 mm 124
180-2018 ZnSe, 19 x 2 mm 124
180-2019 CsI, 19 x 2 mm 124
180-2020 KBr, 14 x 2 mm 124
180-2021 BaF2, 14 x 2 mm 124
180-2022 Si, 14 x 2 mm 124
180-2023 Quartz, 14 x 2 mm 124
180-2024 ZnSe, 14 x 2 mm 124
180-2025 CsI, 14 x 2 mm 123
181-1100 CrushIR Hydraulic Press 98
181-1110 CrushIR Hydraulic Press, Evacuable Pellet Press and Magnetic Holder 98
181-1120 CrushIR Heated Platens Package 98
181-1300 Auto-CrushIR Hydraulic Press, 110 V 99
181-1302 Auto-CrushIR Hydraulic Press, 220 V 99
181-1310 Auto-CrushIR, with Evacuable Pellet Press and Magnetic Holder, 110 V 99
181-1312 Auto-CrushIR, with Evacuable Pellet Press and Magnetic Holder, 220 V 99
181-2000 Heated Platens Accessory 97, 99
181-3000 Spacer Set (15, 25, 50, 100, 250, 500 microns) 97
181-3020 Aluminum Disks 97
181-3010 to Spacer, 15 micron 97181-3015
198-1623 Manual Glan-Taylor 130
198-1624 Manual UV Glan-Thompson 130
198-1625 Automated Glan-Taylor 130
198-1626 Automated UV Glan-Thompson 130
300-0002 Gold Substrate Alignment Mirror, 1.25" x 3.0" 45, 47, 48, 49, 50, 74
300-0025 Gold Surfaced Disk for Reflection Analysis, 13 mm 70, 71
300-0039 Alignment Mirror 46
300-0300 UV Aluminum Mirror, 25.4 mm x 25.4 mm 131, 133
300-0301 UV Aluminum Mirror, 38.1 mm x 38.1 mm 132
430-1110 Vacuum Pump, 110 V 96, 98
430-1220 Vacuum Pump, 220 V 96, 98
13_Index 12-13-12_39131 107-122 12/13/12 1:38 PM Page 156
ORDERING TERMS, CONTACT INFORMATION AND GUARANTEE
Part Numbers and PriceThe PIKE price list includes accessories that may be used with a variety of makes and models of spectrometers. Please specifythe part number and description when ordering, includingyour instrument type and model number. The table listed onthe last page fold-out of this catalog summarizes instrumentcodes for most FTIR manufacturers. These codes are substitutedfor the final two digits (XX) in the accessory part number. PIKE Technologies is continually extending the accessory product range. If you are unable to find a required item, pleasecontact us to discuss your needs. We will be glad to assist.
Payment TermsPurchase Order Number, C.O.D, Letter of Credit, Cash in advance, MasterCard and Visa are acceptable. Payment is net 30 days, and shipments are FOB Madison, WI USA. Freightcharges are prepaid and added to your invoice. If you wish topay freight charges, please specify this on your order.
International Handling FeeFor orders placed from outside the United States or Canada, a handling fee of $40 will apply per order to cover the costs associated with the additional documentation and bankcharges required for international shipments.
Ways to OrderPlease include the following information for all orders: yourname, phone number, product part number, quantity, ship toaddress, bill to address, purchase order number or credit cardnumber with expiration date and name as they appear on thecard, and spectrometer model on which the accessory will beused. You can place your orders via mail, phone, fax, e-mail orinternet. An electronic order form is available on our web page(for P.O. Numbers only – do not use this form for credit cardorders). There is no minimum order requirement.
Please use the following addresses and phone/fax numbers when placing your orders:
PIKE Technologies, Inc. 6125 Cottonwood Drive Madison, WI 53719
(608) 274-2721 (608) 274-0103 (FAX)
[email protected] (E-MAIL) www.piketech.com
DeliveryMost items are available ex-stock, and can be shipped to youwithout delay. PIKE will notify you if the required item is temporarily out of stock. The delivery/shipment date is confirmed upon receipt of an order.
Special requirements and custom accessories are subjectto different lead times. Please contact us for price quotes anddelivery information on these products.
GuaranteeAll PIKE products are guaranteed to be free from defects inmaterial and workmanship for a period of 12 months from the date of shipment. Should you be dissatisfied, or have anyqueries, please contact us immediately and we will promptlyrepair or replace the product at no charge.
Product ReturnsPlease contact PIKE to receive your Return Material Authorization(RMA) number if you wish to return any of our products. Customers are responsible for shipping charges for all returnedproducts. For products under warranty, back to customer shipping charges will be covered by PIKE. Please do not return any products without obtaining the RMA number first.
Technical AssistancePIKE Technologies offers comprehensive technical assistance.Please contact us via mail, phone, fax or e-mail with your questions.
International DistributionPIKE Products are available worldwide. Call or send us an e-mail and we will provide you with an address of the sales office closest to your location. All exports are handled in accordance with the US Export Administration Regulations.
PIKE Technologies on the WebVisit our web site to find out more information about newproducts, up-to-date PIKE news, pricing, and to see the latestcopy of the PIKE Reflections Newsletter!
www.piketech.com • [email protected]
Customer satisfaction is very important to all of us here at PIKE Technologies, Inc. We have hopefully made the orderingprocess very fast and simple for you. If you have any questionsor concerns about our products or services, please don’t hesitate to contact us. We will be happy to make adjustmentsto fit your needs.
Products and prices are subject to change without notification.
©2013 PIKE Technologies, Inc.
Horizon MB™ belongs to ABB; Luer-Lok™ belongs to Becton Dickenson; Equinox™, IFS™, Quick-Lock™, Tensor™, Vector and Vertex™ belongs to Bruker Optics Inc.; CAB-O-SIL® belongs to Cabot Corporation; Pyrex® belongs to Corning Glass Works; Delrin®, Kalrez®, Teflon®, and Viton® belong to E.I. du Pont de Nemours and Company; Interspec belongs to Interspectrum OU; Spectra Manager™ belongs to Jasco, Inc; Winspec™ belongs to JEOL; EMCOMPRESS® belongs to JRS Pharma; InfraLUM® and SpectraLUM/Pro® belongs to Lumex Ltd; Visual BASIC™ and Windows belongs to Microsoft Corporation; Fluorolube® belongs to OxyChem Corporation; Spectrum™ and Spectrum 10™ belongs to PerkinElmer, Inc; Nujol™ belongs to Schering-Plough; IRPrestige™ belongs to Shimadzu Corporation; Swagelok® belongs to Swagelok Company; Avatar™, Genesys™, Impact™, iS™5, iS™10, iS™50,Magna-IR™, Nexus™, Nicolet™, WinFirst™, OMNIC™ and Protégé™ belong to Thermo Fisher Scientific; Excalibur™, Resolutions Pro™ and Scimitar™ belong to Varian, Inc. All other trademarks are the property of PIKE Technologies.
FA X O R D E R F O R M
Date ____________________________________________________
Name ___________________________________________________
Telephone Number ________________________________________
E-mail ___________________________________________________
Fax Number ______________________________________________
PIK
ET
EC
HN
OL
OG
IES
WW
W.
PIK
ET
EC
H.
CO
M6
08
-27
4-2
72
1
144
S H I P P I N G A D D R E S S
Company Name___________________________________________
Address __________________________________________________
City _____________________________________________________
State _______________________________ Zip Code ____________
Attention ________________________________________________
B I L L I N G A D D R E S S
Company Name___________________________________________
Address __________________________________________________
City _____________________________________________________
State _______________________________ Zip Code ____________
Attention ________________________________________________
� Same as Shipping Address
S P E C I A L R E Q U I R E M E N T S / C O M M E N T S
Fax to: 608-274-0103
� P.O. � MasterCard � Visa
P.O. Number______________________________________________
Card Number _____________________________________________
Card Security Number______________________________________
Issued to _________________________________________________
Expiration Date ___________________________________________
Terms: Payment net 30 days; Ship FOB: Madison, WI (typically UPS Blue) unless specified otherwise.
PA R T N U M B E R D E S C R I P T I O N Q U A N T I T Y
FTIR INSTRUMENT CODE XX
ABB Bomem FTLA2000-100 (Arid Zone) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80 Michelson 100, MB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 MB 3000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 82
Analect/Hamilton Sundstrand Diamond 20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Bruker Optics IFS™, Vector™, Equinox™ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 Tensor™, Vertex™ with recognition (Quick-Lock) . . . . . . . . . . . . . . . . . . . . . . . . 51
Buck Scientific M500 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65
Digilab/Bio-Rad/Varian/Agilent Excalibur™, Scimitar™, FTS, 600-IR Series Cary 600/6000 Series . . . . . . . . . . . . 10 Excalibur, Scimitar, 600-IR Series Cary 600/6000 Series with recognition . . . . . 13
Horiba 7000 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Interspectrum Interspec 200-X . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 90
Jasco 300/600 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56 400. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 4000/6000 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58 4000/6000 Series with recognition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
JEOL Winspec™ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Lumex InfraLUM® FT-02, FT-08 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 67
Midac M Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
ORIEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
PerkinElmer 1700 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70 Spectrum™ GX, 2000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 Spectrum BX/RX, 1600, Paragon 1000 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73 Spectrum ONE, 65, 100, 400, FRONTIER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74 Spectrum TWO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75
Shimadzu 8300, 8400 Series, IRPrestige, IRAffinity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 IRPrestige, IRAffinity with recognition (QuickStart) . . . . . . . . . . . . . . . . . . . . . . 16
Thermo Fisher Scientific/Nicolet/Mattson Infinity, Galaxy, RS Series. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Genesys™, Satellite, IR 300 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Impact™ 400, Magna-IR™, Protégé™, 500/700 Series, Avatar™, Nexus™, Nicolet™ Series, Nicolet iS™10, Nicolet iS™50 . . . . . . . . . . . . . . . . . . . 40 Nicolet iS™5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Please contact PIKE for UV-Vis instrument codes
6125 Cottonwood DriveMadison, WI 53719
(608) 274-2721(608) 274-0103 (FAX)
WWW. P I K E T E CH . COM