pipenet detailed
DESCRIPTION
pipenetTRANSCRIPT
![Page 1: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/1.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
SUNRISE SYSTEMSPIPENET VISION
DETAILED DEMONSTRATION AND
DISCUSSION OF APPLICATIONS
![Page 2: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/2.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATIONS
• Transient Analysis of Pipelines
• Firewater Systems
• Water Injection Systems
• Cooling Water Systems
• Loading and Unloading Systems
• Generating Loads for Pipe Stress Analysis
![Page 3: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/3.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATIONSURGE ANALYSIS OF A LARGE COOLING WATER
SYSTEMNANHAI PETROCHEMICAL PLANT, CHINA
![Page 4: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/4.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATIONSURGE ANALYSIS OF A LARGE COOLING WATER
SYSTEMNANHAI PETROCHEMICAL PLANT, CHINA
KEY POINTS
• One of the Biggest Petrochemical Plants• Main Header Is 2.0 M Diameter• Plant Has 4 Systems in Parallel• Cooling Water System Uses GRP• Open System With Cooling Tower• Slow Valve Closure Necessary – 240 Sec• Severe Oscillations After Valve
• Valve Closure Scenario• Pump Trip Scenario
![Page 5: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/5.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATIONSURGE ANALYSIS OF A LARGE COOLING WATER
SYSTEMNANHAI PETROCHEMICAL PLANT, CHINA
OBJECTIVES
• Reduce Oscillations To Less Than 1 Bar
• Keep Pressure Surge to Less Than 8 Barg
• Optimise Valve Closure Time
![Page 6: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/6.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATIONSURGE ANALYSIS OF A LARGE COOLING WATER
SYSTEMNANHAI PETROCHEMICAL PLANT, CHINA
• Downstream pressure with 240 sec closure
![Page 7: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/7.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATIONSURGE ANALYSIS OF A LARGE COOLING WATER
SYSTEMNANHAI PETROCHEMICAL PLANT, CHINA
• Downstream pressure with 40 sec closure
![Page 8: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/8.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATIONSURGE ANALYSIS OF A LARGE COOLING WATER
SYSTEMNANHAI PETROCHEMICAL PLANT, CHINA
![Page 9: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/9.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATIONSURGE ANALYSIS OF A LARGE COOLING WATER
SYSTEMNANHAI PETROCHEMICAL PLANT, CHINA
• Pressure Range with 240 Sec Valve Closure
![Page 10: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/10.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATIONSURGE ANALYSIS OF A LARGE COOLING WATER
SYSTEMNANHAI PETROCHEMICAL PLANT, CHINA
• Pressure Range with 60 Sec Valve Closure
![Page 11: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/11.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATIONSURGE ANALYSIS OF A LARGE COOLING WATER
SYSTEMNANHAI PETROCHEMICAL PLANT, CHINA
CONCLUSIONS
• Pressure Range Is Below 1 Bar
• Maximum Pressure Is Below 8 Barg
• 240 Sec Valve Closure Time Is Necessary
![Page 12: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/12.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION OFFSHORE FIREWATER SYSTEM
NOWROOZ OFFSHORE PLATFORM COMPLEX, IRAN
Fire pump 20-P-4510B
20-A-4502
NPP2 Platform
NLQ Platform
20-A-4503
20-A-4504
Weather deck
Closed
Closed
Closed
Vac Brkr
Vac Brkr
Vac Brkr
Vac Brkr
Vac Brkr
Runs constantly
Caisson modelled as pipe
Monitor closes5 - 10 secs
![Page 13: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/13.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION OFFSHORE FIREWATER SYSTEM
NOWROOZ OFFSHORE PLATFORM COMPLEX, IRAN
KEY POINTS
• Operator Is Shell, In Offshore Iran
• Two Sister Platform Complexes – Soroosh (3 Platforms) And Nowrooz (2 Platforms)
• The Firewater Ringmain Is Made Of GRP Pipes
• Pressure Controlled Deluge Valves Were Used
• Bridge Connection Between The Platforms. (So There Is Large Volume)
![Page 14: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/14.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION OFFSHORE FIREWATER SYSTEM
NOWROOZ OFFSHORE PLATFORM COMPLEX, IRAN
OBJECTIVES
• To calculate the maximum pressure surges and check if they are within the limit – deluge valve closure, deluge valve opening and pump trip
• Check the need for vacuum breakers, their position and sizes
• Check stability of the control valve
• Calculate hydraulic transient forces for pipe stress analysis, and positioning pipe supports.
![Page 15: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/15.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION OFFSHORE FIREWATER SYSTEM
NOWROOZ OFFSHORE PLATFORM COMPLEX, IRAN
POINTS OF SPECIAL INTEREST
• Elevation Changes in Offshore Platforms often cause large pressure surges due to cavity formation. Vacuum breakers are used to eliminate them.
• In this system, the large capacity of the bridge connection between the platforms combined with the elasticity of GRP material was instrumental in reducing the pressure surge. GRP is generally thought to be bad for pressure surge but in this case it was good.
![Page 16: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/16.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION OFFSHORE FIREWATER SYSTEM
NOWROOZ OFFSHORE PLATFORM COMPLEX, IRAN
![Page 17: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/17.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION SUBSEA PIPELINE SYSTEM – ARABIAN GULF
ZADCO, ABU DHABI
![Page 18: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/18.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION SUBSEA PIPELINE SYSTEM – ARABIAN GULF
ZADCO, ABU DHABI
KEY POINTS
• 35 Km Pipeline Transporting Oil From Platform To Tank Farm
• Two Specific Problems– Pipeline Is 25 Years Old And Is Corroded– Water Cut In Oil Is High – Less Compressible –
High Pressure Surge
• Feasibility Analysis Of Leak Detection System
![Page 19: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/19.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION SUBSEA PIPELINE SYSTEM – ARABIAN GULF
ZADCO, ABU DHABI
OBJECTIVES
• Determine The Valve Closure Time For Maximum Pressure Of Closed Head Pressure Of Pump Plus 5 Barg
• Determine The Volume Of Oil Leakage With And Without Leak Detection System
![Page 20: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/20.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION SUBSEA PIPELINE SYSTEM – ARABIAN GULF
ZADCO, ABU DHABI
• VALVE CLOSURE TIME OF 60 SEC
![Page 21: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/21.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION SUBSEA PIPELINE SYSTEM – ARABIAN GULF
ZADCO, ABU DHABI
VALVE CLOSURE TIME – 600 SEC LINEAR
![Page 22: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/22.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION SUBSEA PIPELINE SYSTEM – ARABIAN GULF
ZADCO, ABU DHABI
VALVE CLOSURE TIME – 600 SEC QUADRATIC
![Page 23: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/23.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION SUBSEA PIPELINE SYSTEM – ARABIAN GULF
ZADCO, ABU DHABI
![Page 24: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/24.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION SUBSEA PIPELINE SYSTEM – ARABIAN GULF
ZADCO, ABU DHABI
CONCLUSION
The shut off valve must be closed no faster than 600 sec in quadratic mode
![Page 25: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/25.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION JETTY LOADING SYSTEM
ENGINEERING COMPANY, KOREA
![Page 26: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/26.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION JETTY LOADING SYSTEM
ENGINEERING COMPANY, KOREA
KEY POINTS
• 5700 M Pipeline From Refinery to Ship
• Carrying Lube Oil
• Maximum Pressure Is Limited to 15 Barg
• Environmental Considerations Are Crucial
• Planned Shut Down As Well As Emergency Shut Down Need to Considered
![Page 27: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/27.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION JETTY LOADING SYSTEM
ENGINEERING COMPANY, KOREA
OBJECTIVES
• To reduce the maximum pressure to 15 barg.• Consider alternative strategies for reducing the
pressure surge.• Determine the best position for the surge relief device• Calculate the forces on the expansion loop• Optimise the size of surge relief valve
![Page 28: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/28.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION JETTY LOADING SYSTEM
ENGINEERING COMPANY, KOREA
ALTERNATIVE STRATEGIES
• Two Stage Valve Closure
• Use Surge Relief Valve
• Use Accumulator
![Page 29: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/29.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION JETTY LOADING SYSTEM
ENGINEERING COMPANY, KOREA
25 Sec Linear Valve Closure
![Page 30: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/30.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION JETTY LOADING SYSTEM
ENGINEERING COMPANY, KOREA
USE OF SURGE RELIEF VALVE
Pipeline
Sh ut off valve
ERC valve
Jetty
Pe trochemical plant
Tanker(C loses)
(Remains open)
Su rge Relief Valve
![Page 31: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/31.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION JETTY LOADING SYSTEM
ENGINEERING COMPANY, KOREA
SURGE RELIEF VALVE, CV = 200 (M3/HR, BAR)
![Page 32: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/32.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION JETTY LOADING SYSTEM
ENGINEERING COMPANY, KOREA
SURGE RELIEF VALVE, CV = 100 (M3/HR, BAR)
![Page 33: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/33.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION JETTY LOADING SYSTEM
ENGINEERING COMPANY, KOREA
SURGE RELIEF VALVE, CV = 25 (M3/Hr, BAR)
![Page 34: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/34.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION JETTY LOADING SYSTEM
ENGINEERING COMPANY, KOREA
SURGE RELIEF VALVE, CV = 10 (M3/Hr, BAR)
![Page 35: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/35.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION JETTY LOADING SYSTEM
ENGINEERING COMPANY, KOREA
POSITIONING OF SURGE RELIEF VALVE, CV = 100 (M3/Hr, BAR)
Pipeline
Shut off valve
ERC valve
JettyPetrochemical plant
Tanker(Closes)
(Remains open)
Surge Relief Valve
![Page 36: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/36.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION JETTY LOADING SYSTEM
ENGINEERING COMPANY, KOREA
POSITIONING OF SURGE RELIEF VALVE, CV = 100 (M3/Hr, BAR)
![Page 37: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/37.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION JETTY LOADING SYSTEM
ENGINEERING COMPANY, KOREA
TWO STAGE VALVE CLOSURE – NO SURGE RELIEF VALVE
Pipeline
Sh ut off valve
ERC valve
Jet ty
Pe trochemical plant
Tanker(Closes)
(Remains op en)
![Page 38: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/38.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION JETTY LOADING SYSTEM
ENGINEERING COMPANY, KOREA
TWO STAGE VALVE CLOSURE – SLOW SECOND STAGE
![Page 39: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/39.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION JETTY LOADING SYSTEM
ENGINEERING COMPANY, KOREA
TWO STAGE VALVE CLOSURE – FAST SECOND STAGE
![Page 40: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/40.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION JETTY LOADING SYSTEM
ENGINEERING COMPANY, KOREA
SINGLE STAGE VALVE CLOSURE – WITH ACCUMULATOR
Pipeline
Shut off valve
ERC valve
Jetty
Petrochemical plant
Tanker(Closes)
(Remains open)
![Page 41: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/41.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION JETTY LOADING SYSTEM
ENGINEERING COMPANY, KOREA
SINGLE STAGE VALVE CLOSURE – WITH ACCUMULATORDiameter = 1.0 m, height = 15 m
![Page 42: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/42.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION JETTY LOADING SYSTEM
ENGINEERING COMPANY, KOREA
SINGLE STAGE VALVE CLOSURE – WITH ACCUMULATORDiameter = 0.5 m, height = 10 m
![Page 43: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/43.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION JETTY LOADING SYSTEM
ENGINEERING COMPANY, KOREA
FORCE CALCULATION AT AN EXPANSION LOOP
PipelineShut off valve
ERC valve
Jetty
Petrochemical plant
Tanker(Closes)
(Remains open)
EXPANSION LOOP
2000M
10M
100M10M
![Page 44: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/44.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION JETTY LOADING SYSTEM
ENGINEERING COMPANY, KOREA
FORCE CALCULATION AT AN EXPANSION LOOP
![Page 45: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/45.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION JETTY LOADING SYSTEM
ENGINEERING COMPANY, KOREA
FORCE CALCULATION AT AN EXPANSION LOOP
![Page 46: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/46.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION JETTY LOADING SYSTEM
ENGINEERING COMPANY, KOREA
FORCE CALCULATION AT AN EXPANSION LOOP
![Page 47: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/47.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION RAS LAFFAN COMMON COOLING WATER SYSTEM
QATAR PETROLEUM
![Page 48: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/48.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION RAS LAFFAN COMMON COOLING WATER SYSTEM
QATAR PETROLEUM
KEY POINTS 1• Most complex cooling water system ever
designed• Made of GRP material• Main header size in Phase 1 of the project was
3.5 m diameter• Main header size in Phase 2 of the project was
4.5 m diameter• The system has 9 variable speed pumps with
pressure control (7 lead, 2 stand by)• The system (Phase 1) has 190 vacuum breakers
![Page 49: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/49.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION RAS LAFFAN COMMON COOLING WATER SYSTEM
QATAR PETROLEUM
KEY POINTS 2• Each pump had a capacity of some 48,000
m3/hr, making a total of 336,000 m3/hr• There were flow control valves in the system• The allowable working pressure had a very
narrow range.– Minimum pressure = -0.3 barg– Maximum pressure = 6.0 barg
• The system has two receiving basins to stop air flowing back into the system if the pumps tripped
• PIPENET was specified for the project by Qatar Petroleum.
![Page 50: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/50.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION RAS LAFFAN COMMON COOLING WATER SYSTEM
QATAR PETROLEUM
OBJECTIVES
• To size the receiving basins• To select the vacuum breakers and ensure their
adequacy• To check the stability of the control systems• The users were plants operated by other
companies. It was necessary to guarantee availability of water.
• Optimise the control systems in order to minimise power consumption
• Safe operation under pump trip and valve closure events.
![Page 51: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/51.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION RAS LAFFAN COMMON COOLING WATER SYSTEM, QP
ZOOMED VIEW 1
![Page 52: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/52.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION RAS LAFFAN COMMON COOLING WATER SYSTEM, QP
ZOOMED VIEW 2
![Page 53: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/53.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION RAS LAFFAN COMMON COOLING WATER SYSTEM, QP
![Page 54: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/54.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION RAS LAFFAN COMMON COOLING WATER SYSTEM, QP
![Page 55: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/55.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATION RAS LAFFAN COMMON COOLING WATER SYSTEM, QP
![Page 56: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/56.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATIONFIREWATER RINGMAIN SYSTEM TRANSIENT ANALYSIS
EASTERN BECHTEL CO. LTD.
![Page 57: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/57.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATIONFIREWATER RINGMAIN SYSTEM TRANSIENT ANALYSIS
EASTERN BECHTEL CO. LTD.ZOOMED VIEW 1
![Page 58: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/58.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATIONFIREWATER RINGMAIN SYSTEM TRANSIENT ANALYSIS
EASTERN BECHTEL CO. LTD.ZOOMED VIEW 2
![Page 59: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/59.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATIONFIREWATER RINGMAIN SYSTEM TRANSIENT ANALYSIS
EASTERN BECHTEL CO. LTD.
KEY POINTS• Liquefied Natural Gas Plant (LNG)• GASCO, Abu Dhabi• Mixture of Carbon steel, Lined/Unlined and
GRP• Complicated bypass valve arrangement• Pump Startup with no system running• Pump startup with the largest system
running• Pump trip
![Page 60: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/60.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
TRANSIENT MODULE APPLICATIONFIREWATER RINGMAIN SYSTEM TRANSIENT ANALYSIS
EASTERN BECHTEL CO. LTD.Monitor Valve Closing Case
![Page 61: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/61.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
SPRAY/SPRINKLER MODULE APPLICATIONS
• Deluge systems
• Firewater ring mains
• Foam solution systems
• Sprinkler systems
![Page 62: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/62.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
SPRAY/SPRINKLER MODULE APPLICATION REFINERY FIREWATER RINGMAIN SYSTEM
M W KELLOGG, UNITED KINGDOM
![Page 63: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/63.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
SPRAY/SPRINKLER MODULE APPLICATION REFINERY FIREWATER RINGMAIN SYSTEM
ZOOMED VIEW
![Page 64: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/64.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
SPRAY/SPRINKLER MODULE APPLICATIONAIRPORT HANGAR DELUGE SYSTEM
SINGAPORE INTERNATIONAL AIRPORT
891 PIPES730 NOZZLES
![Page 65: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/65.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
SPRAY/SPRINKLER MODULE APPLICATIONAIRPORT HANGAR FIREWATER SYSTEM
ZOOMED VIEW
![Page 66: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/66.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
SPRAY/SPRINKLER MODULE APPLICATIONOFFSHORE PLATFORM COMPLEX FIREWATER
SYSTEMDANF PLATFORMS, DENMARK
![Page 67: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/67.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
SPRAY/SPRINKLER MODULE APPLICATIONOFFSHORE PLATFORM COMPLEX FIREWATER
SYSTEMZOOMED VIEW
![Page 68: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/68.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
STANDARD MODULE APPLICATIONS
• Cooling Water Systems
• Steam Distribution Systems
• Ventilation Systems
• Compressed Air Systems
• Seawater Systems
• Closed Loop Systems
![Page 69: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/69.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
STANDARD MODULE APPLICATIONREFINERY STEAM DISTRIBUTION SYSTEM
RELIANCE INDUSTRIES, INDIA
![Page 70: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/70.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
STANDARD MODULE APPLICATIONREFINERY STEAM DISTRIBUTION SYSTEM
ZOOMED VIEW 1
![Page 71: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/71.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
STANDARD MODULE APPLICATIONREFINERY STEAM DISTRIBUTION SYSTEM
ZOOMED VIEW 2
![Page 72: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/72.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
STANDARD MODULE APPLICATIONPLANT COOLING WATER SYSTEM
QATAR PETROLEUM
![Page 73: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/73.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
STANDARD MODULE APPLICATIONPLANT COOLING WATER SYSTEM, QP
ZOOMED VIEW 1
![Page 74: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/74.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
STANDARD MODULE APPLICATIONPLANT COOLING WATER SYSTEM, QP
ZOOMED VIEW 2
![Page 75: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/75.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
STANDARD MODULE APPLICATIONPLANT WATER DISTRIBUTION SYSTEM
![Page 76: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/76.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
STANDARD MODULE APPLICATIONPLANT WATER DISTRIBUTION SYSTEM
ZOOMED VIEW
![Page 77: Pipenet Detailed](https://reader036.vdocuments.net/reader036/viewer/2022081416/5695d0161a28ab9b0290ea73/html5/thumbnails/77.jpg)
PIPENETTM - Leading the Way in Fluid Flow Analysis
SUNRISE SYSTEMS LIMITED
Flint BridgeBusiness CentreEly RoadWaterbeach Cambridge CB5 9QZUnited Kingdom
Tel.: +44 1223 441311Fax:+44 1223 441297
E-mail:[email protected]
Web:www.sunrise-sys.com
DIFFERENCES BETWEEN PIPENET AND TWO-PHASE FLOW PROGRAMS
ITEM PIPENET TWO-PHASE FLOW
Thermodynamics Simple Complex
Network Complex Simple
Main Systems Utility systems, firewater systems, surge analysis
Two-phase flow pipelines, process lines
Main applications Steady state (Design), Transient state (Analysis)
Steady State
Priority 1 Fast input of complex networks
Good thermodynamics
Priority 2 Fast calculations and reliable results
Reliable results