pj-a77tv-b instructin manual - sharp malaysia...pj-a77tv-b air cooler. 220-240v~ 50hz fig 1 fig 2 4...

5
The product is subject to change without notice. The graphs in this instruction manual may be different from the actual products; please refer to the actual products. PJ-A77TV-B AIR COOLER

Upload: others

Post on 22-Jan-2021

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PJ-A77TV-B Instructin Manual - SHARP Malaysia...PJ-A77TV-B AIR COOLER. 220-240V~ 50Hz fig 1 fig 2 4 This unit is not applicable to be used in high-temperature environment. Do not put

The product is subject to change without notice. The graphs in this instruction manual may be different from the actual products; please refer to the actual products.

PJ-A77TV-BAIR COOLER

Page 2: PJ-A77TV-B Instructin Manual - SHARP Malaysia...PJ-A77TV-B AIR COOLER. 220-240V~ 50Hz fig 1 fig 2 4 This unit is not applicable to be used in high-temperature environment. Do not put

220-240V~ 50Hz

fig 1 fig 2

4 This unit is not applicable to be used in high-temperature environment. Do not put the unit at a high-temperature or low-temperature place. Water inside the water tank may be deteriorated easily in summer, please replace water in time. When room temperature is lower than 0 , please use warm water for humidifying. After operation is finished, dry the water in water tank with towel in time.5.Use wet cloth (or add some detergent) to wipe the outer surface of the unit. Do not use corrosive abluent or solvent to clean the surface. Prohibit washing the unit with water(see fig 4).

3.Do not put heavy objects on the top of the unit. Prohibit covering air outlet and air inlets at both sides (see fig 3). There should be no objects within 1m away from the unit.

Safety Notices

fig 3 fig 4

Air inlet Air inlet

1.Use normal power supply 220-240V~ 50Hz and use the independent 3A or 3A above socket which with national standard to ensure the safety (see fig 1).2.After the unit is filled with water, please push the unit slowly if you have to move the unit to prevent water overflowing. Prohibit tilting the unit during operation to prevent accident. (see fig 2)

-1-

Page 3: PJ-A77TV-B Instructin Manual - SHARP Malaysia...PJ-A77TV-B AIR COOLER. 220-240V~ 50Hz fig 1 fig 2 4 This unit is not applicable to be used in high-temperature environment. Do not put

6.If it needs to be stored or transported, drain out the water, operate at normal wind mode for approx. 30 mins to dry up the evaporator and then pack the unit.7.When the unit will not be used for a long time, please pull out the power plug to prevent damage to the unit.8.If the supply cord is damaged, it must be replaced by the manufacturer, its authorised service agent to avoid hazard.9.The unit is with humidifying effect; please do not operate the unit in enclosed environment. If you operate the unit in enclosed environment, please turn off humidifying and cooling function.10.When water level is lower than the minimum water level, please add water in time.11.This appliance is not intended for use by persons (including children)with reduced physical, sensory or mental capabilitiesor lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.12.Note:Before maintenance or disassembling the outer case, the unit must be disconnected with the power supply..

-2-

Standby: Once the unit is turned on, all indicators will be on for 1 second.Then, the unit will enter standby status.ON/OFF button: Press this button to turn on the unit under standby mode. The

default working status is level 1 normal wind; Press this button again to turn off the unit.

Fan Speed button: Under working status, press this button to set fan speed. Press this button repeatedly to select fan speed circularly.

Wind Mode button: Press this button under working status to select fan mode. Press this button continuously to select fan mode circularly in the sequence of: natural wind sleeping wind normal wind. There's no icon for general wind. If selecting natural wind or sleeping wind, corresponding icon will be turned on.

Air swing button: under working status, press this button to select air swing. Pressing this button repeatedly can select fan mode circularly.

When swinging, the corresponding icon will light up.

Cooling button: Press this button once under working status to start up cooling function. Water pump will start working and cool indicator is on. Press this button again to stop cool function. Water pump stops operation and cool indicator will be off.

Light button: Press this button for the first time and all indicators light will be turned off; press this button again and indicator light will be turned on.

-3-

Product Features

13.Unplug the appliance during water filling and cleaning.14.Ensure that the unit is switched off from the supply mains before removing the guard.15.This product is only for household use.

Timer button: Timer off function: Press this button under working status to set timer off function. Press this button continuously to set timer off time circularly in the sequence of 1h 2h 3h …… 15h. Timer on function: Press this button under standby status to set preset on function. Press this button continuously to set preset on time circularly in the sequence of 1h 2h 3h …… 15h. When preset on time is reached, preset indicator is off and the fan will be turned on automatically. The defaulted preset working status is low speed, normal wind, 2h timer off and air swing.

Page 4: PJ-A77TV-B Instructin Manual - SHARP Malaysia...PJ-A77TV-B AIR COOLER. 220-240V~ 50Hz fig 1 fig 2 4 This unit is not applicable to be used in high-temperature environment. Do not put

Water level protection: When the water level is low, water pump

will stop operation and buzzer will beep three times to alarm low water- level. Cooling indicator is flashing. Under cooling mode, fan motor won't be affected during low water level protection; (This function is only valid when cooling function is turned on).Note: After opening the air intake panel, the unit will be turned off automatically.

-4-

Operating Console and Display Panel

Air Guide, Swing Louver

Panel Clasp

Air InletAir Intake Panel

Power Cord HookerWater Tank (Inside)

Castor (With brake)

Outline Structure and Parts' Name

Specifications

Note: Water consumption will vary, depending on different of ambient humidity.

Operation Instruction

-5-

1.Unpack the carton box, take out the unit and check if all accessories are available.2.Add water: rotate the water tank lock in clockwise direction and then draw out the water tank (see fig 3).Note: Before adding water, please remove the pearl wool sticking at the left side of water tank.

When using the unit for the first time or the unit hasn't been used for a long time, please use clean water. Pull out the power plug before adding water to prevent electrical hazard.

Add water to “max water level” as indicated to prevent overflow.3.Push in the water tank, rotate the water tank lock in an anticlockwise to secure the water tank (see fig 2), and then install the air intake panel (see fig 1).

4.Operation of remote controller: the functions for some buttons on remote controller are same with those for buttons on control panel. Point the infrared transmitting tube at the main body directly. There should be no obstacles between the remote controller and the unit.5.Storage: If the unit will not be used for a long time, pour out the water from the water tank completely, and then operate it at room temperature for approx.

lock of water tank

(fig 1)

water tank

Maximum water level

Minimum water level

water tank

(fig 2) (fig 3)

Model Rated Power Noise Water Tank

Capacity Air Volume TypeRated Power Supply

Evaporation Capacity

7.0A) Cooling401000mL h220-240V~ 50HzPJ-A77TV-B

Accessories

Ice pack x4 Remote control x1(batteries included)

Displayed icon illustration

Cooling

Timer

Timer On

Swing

Sleeping wind

Natural wind

Page 5: PJ-A77TV-B Instructin Manual - SHARP Malaysia...PJ-A77TV-B AIR COOLER. 220-240V~ 50Hz fig 1 fig 2 4 This unit is not applicable to be used in high-temperature environment. Do not put

-6-

Troubleshooting

No wind1.Not put through the power2.Hasn't turn on the unit3.The body is damaged

1.Insert the power cord by the correct method2.Press ON/OFF button to start up the unit3.Send it to maintenance center

Malfunction Causes Troubleshooting

No power

Can't turn on the unit

There's abnormal sound

Can't change the wind direction

No cooling

Air-in panel hasn't been installed well

Malfunction of synchronous motor

1.The strainer at the air inlet is blocked2.Water channel is blocked3.Other causes

1.There's sediments inside the unit2.The impeller is loose3.Malfunction of motor

The body is damaged

Install the air-in panel tightly

1.Remove filter and then take out the sundries2.Send it to maintenance center3.Send it to maintenance center

1.Clean the filter at the water inlet2.Clean the water channel3.Send it to maintenance center

Send it to maintenance center

Send it to maintenance center

1.During operation, prohibit opening the ice pack cover or consuming the gel in ice pack is strictly prohibited. 2.Put the ice pack in the freezer to freeze for about 4h, and then put 2 packs into the water tank (add water inside water tank before putting the ice box in water tank).3.The ice pack will reduce the water temperature and produce cool air flow.

5.Please make sure to insert the ice pack at the designated location to prevent damage to the water pump.

ice pack

Operation Instruction for Ice Pack

-7-

(6)Wash the water tank, filter of water tank, evaporator and filter of evaporator with clean water, and then reinstall them correctly and securely.

Evaporator Filter of evaporator Filter of

water tank

(7)Put the evaporator at the appointed position of the unit. Otherwise, it may affect the normal operation and service life. (even the motor may be burnt out)

(8)When moving the unit, please check whether there's water inside water tank. If yes, please drain the water out completely. Note: Prohibit tilting and pulling the unit when there's water inside water tank to prevent water overflow.

Filter of water tank

Fig 4 Fig 5

Fixed rack of evaporator

Filter of evaporator

30mins to dry the evaporator. Cover the unit with plastic bag, and then put it carton box for storage.6.Cleaning: When the unit has been operated for a long time, water tank, filter of water tank, evaporator and filter of evaporator will be blocked by sediment and the air volume and cooling effect will be decreased. It is recommended to clean them every two weeks.Cleaning method:(1)Pull out power plug from wall power socket.(2)Press the clasp of panel with both hands, and then open the air intake panel (see fig 1).

(4)Draw out water tank (see fig 3), and then remove the filter of water tank (see fig 4).(5)Remove the filter of evaporator, and then remove the evaporator (see fig 5).

(3)Unlock the water tank by turning the lock clockwise.4.The equipped ice packs can be used repeatedly by rotating 2 packs in use and 2 packs standby in frozen condition.