pl3 calibration step - swellpro calibration step.pdf · pl3 camera calibration 1、first, install...

6
PL3 Camera Calibration 1First, install the calibration software "SimpleBGC_GUI_2_40" on your Windows computer. 2Loosen the two screws in the red box below and you can see the USB interface. Use the USB cable to link the camera and the computer. 3Place the camera on the horizontal table and press it flat with your hand. 4Run the camera calibration software "SimpleBGC_GUI_2_40". And complete the calibration according to the following steps:

Upload: others

Post on 18-Jun-2020

19 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: PL3 Calibration Step - Swellpro Calibration Step.pdf · PL3 Camera Calibration 1、First, install the calibration software "SimpleBGC_GUI_2_40" on your Windows computer. 2、Loosen

PL3CameraCalibration

1、First,installthecalibrationsoftware"SimpleBGC_GUI_2_40"onyourWindowscomputer.

2、LoosenthetwoscrewsintheredboxbelowandyoucanseetheUSBinterface.UsetheUSB

cabletolinkthecameraandthecomputer.

3、Placethecameraonthehorizontaltableandpressitflatwithyourhand.

4、Runthecameracalibrationsoftware"SimpleBGC_GUI_2_40".Andcompletethecalibration

accordingtothefollowingsteps:

Page 2: PL3 Calibration Step - Swellpro Calibration Step.pdf · PL3 Camera Calibration 1、First, install the calibration software "SimpleBGC_GUI_2_40" on your Windows computer. 2、Loosen

Table1:Clickonthelabeledredbox,selectCOM66orothermaximumvalues,andclickonthe

connection(BlueArrow)

Page 3: PL3 Calibration Step - Swellpro Calibration Step.pdf · PL3 Camera Calibration 1、First, install the calibration software "SimpleBGC_GUI_2_40" on your Windows computer. 2、Loosen

Table 2: After the connection is successful, the parameters on the right will change. The

arrow indicates that the connection is successful. Click Load(red rectangle)

Table3:Afterloading,selectfirmwaremarkedwithredboxandselectOpen

Page 4: PL3 Calibration Step - Swellpro Calibration Step.pdf · PL3 Camera Calibration 1、First, install the calibration software "SimpleBGC_GUI_2_40" on your Windows computer. 2、Loosen

Table4:Selectthewritingoftheredbox,andthearrowinthelowerleftcornerwillshow“从控

制器上成功载入参数”whenthewritingissuccessful.

Table5:clicktheredboxandthearrowinthelowerleftcornerwillshow”加速度计校准开

始”,andthearrowinthelowerrightcornerwillshowaslightchange.

Note:Ifyoucan'tseethevaluejumpinthelowerrightcorner,justwait10secondsforthenext

step.

Page 5: PL3 Calibration Step - Swellpro Calibration Step.pdf · PL3 Camera Calibration 1、First, install the calibration software "SimpleBGC_GUI_2_40" on your Windows computer. 2、Loosen

Table6:SelectCALIBGYRO,thelowerleftcornerwilldisplaytheEnglishletters,andthelower

rightcornerarrowvaluewilljumpslightly.

Note:Ifyoucan'tseethevaluejumpinthelowerrightcorner,justwait10secondsforthenext

step.

Page 6: PL3 Calibration Step - Swellpro Calibration Step.pdf · PL3 Camera Calibration 1、First, install the calibration software "SimpleBGC_GUI_2_40" on your Windows computer. 2、Loosen

Table7:ChooseWriting.ThelowerleftcornerofsuccessfulWritingwillshow”当前配置文件成

功写入控制器”

CalibrationiscompletedandpulledoutUSBcable.CheckwhetherPL3cameraworksproperlyby

electrifying.