A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH CALIFORNIA OSHA REQUIREMENTS. THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY GRID INTERACTIVE SYSTEM. A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH CEC 690.47, 250.50 THROUGH 60, AND 250.166 SHALL BE PROVIDED. PER CEC, GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BE USED AND BONDED TO AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, OR IS ONLY METALLIC WATER PIPING, A SUPPLEMENTAL GROUNDING ELECTRODE WILL BE USED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO GREATER THAN #8 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE OR A COMPLETE GROUND. EACH MODULE WILL BE GROUNDED USING THE SUPPLIED GROUNDING POINTS IDENTIFIED BY THE MANUFACTURER. EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENT, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH CEC 250.134 OR 250.136(A) REGARDLESS OF VOLTAGE. PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED PER CEC 110.26. ALL SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE CEC. HEIGHT OF INTEGRATED AC/DC DISCONNECT SHALL NOT EXCEED 6' 7" PER CEC 240.24. THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE BETWEEN THE GROUNDING ELECTRODE AND THE PANEL (OR INVERTER) IF SMALLER THAN #6 AWG COPPER WIRE PER CEC 250.64(B). THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER CEC 250.64(C). ALL EXTERIOR CONDUIT SHALL BE PAINTED TO MATCH ADJACENT SURFACES. THE PV CONNECTION IN THE PANEL BOARD SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END FROM THE INPUT FEEDER LOCATION OR MAIN CIRCUIT LOCATION PER CEC 705.12 (B)(2)(3)(b). SITE CONDITIONS SHALL PREVAIL IF NO SCALE IS GIVEN. DRAWINGS ARE NOT NECESSARILY TO SCALE. ALL DIMENSIONS SHALL BE VERIFIED BY SUBCONTRACTOR UPON COMMENCEMENT OF CONSTRUCTION. PER THE CA RESIDENTIAL CODE (CRC) § R314 & R315, 10 YEAR BATTERY CARBON MONOXIDE AND SMOKE ALARMS SHALL BE INSTALLED IN EACH SLEEPING AREA AND HALLWAYS LEADING TO SLEEPING AREAS. WIRELESS SYSTEM INFORMATION SYSTEM SIZE PV MODULES RACKING INVERTER(S) ECOFASTEN CLICK-FIT SHEET INDEX IE-01 IE-02 IE-03 IE-04 TITLE SHEET MOUNTING LAYOUT ELECTRICAL DIAGRAM IE-05 LABELING APPLICABLE CODES LEGEND SCOPE OF WORK MOUNTING EXISTING BUILDING INFORMATION STRUCTURE TYPE: RESIDENTIAL OCCUPIED BUILDING ROOF FRAMING: 2"X4" TRUSSES, 24" O.C. ROOF TYPE: STORIES: 2 CONSTRUCTION NOTES M METER INVERTER GROUND SWITCH BREAKER FUSE CONDUIT RUN VICINITY MAP FLAT TILE 9 LONGI: LR4-60HPH-350M 9 ENPHASE IQ7-60-2-US ECOFASTEN CLICK-FIT 3.150 kW DC / 3.055 kW AC PROJECT INFORMATION AHJ SIGNATURE AND DATE SHEET TITLE SHEET NUMBER Infinity Energy 3855 Atherton Rd Rocklin, CA 95765 T:(888)-244-2513 [email protected] CSLB#: 998627 MICHAEL CARLSON 5343 CORMORANT CT. JURUPA VALLEY CA, 91752 SUNNOVA CITY OF JURUPA VALLEY DRAWN BY: DATE: NAME: ADDRESS: CITY: STATE, ZIP: AHJ: FINANCE TYPE: R. KOPBAYEV 8/23/2021 TITLE SHEET IE-01 160-474-005 APN#: SITE PLAN INSTALLATION CONSISTS OF 9 LONGI: LR4-60HPH-350M PV MODULES, 9 MICRO INVERTERS AND RELATED ELECTRICAL METERING (IF USED) AND SAFETY EQUIPMENT. ALL COMPONENTS ARE UL LISTED AND CEC CERTIFIED, WHERE WARRANTED ALL EQUIPMENT WILL BE INSTALLED AS REQUIRED BY APPLICABLE CODES AND LOCAL UTILITY COMPANY REQUIREMENTS. AIR CONDITIONER CHIMNEY A/C DESIGN CRITERIA WIND SPEED: 110 MPH WIND EXPOSURE: C SNOW LOAD: 0 PSF C7.8 R. Kopbayev 2019 CALIFORNIA ELECTRICAL CODE (CEC) 2019 CALIFORNIA BUILDING CODE (CBC) 2019 CALIFORNIA RESIDENTIAL CODE (CRC) 2019 PLUMBING CODE 2019 MECHANICAL CODE 2019 FIRE CODE 2019 ENERGY CODE

Upload: others

Post on 01-Mar-2022

4 views

Category:

Documents


0 download

TRANSCRIPT

A LADDER SHALL BE IN PLACE FOR INSPECTION IN COMPLIANCE WITH CALIFORNIA OSHA REQUIREMENTS.

THE PV MODULES ARE CONSIDERED NON-COMBUSTIBLE AND THIS SYSTEM IS A UTILITY GRID INTERACTIVE SYSTEM.

A GROUNDING ELECTRODE SYSTEM IN ACCORDANCE WITH CEC 690.47, 250.50 THROUGH 60, AND 250.166 SHALL BE PROVIDED. PER CEC, GROUNDING ELECTRODE SYSTEM OF EXISTING BUILDING MAY BEUSED AND BONDED TO AT THE SERVICE ENTRANCE. IF EXISTING SYSTEM IS INACCESSIBLE, OR INADEQUATE, OR IS ONLY METALLIC WATER PIPING, A SUPPLEMENTAL GROUNDING ELECTRODE WILL BEUSED AT THE INVERTER LOCATION CONSISTING OF A UL LISTED 8 FT GROUND ROD WITH ACORN CLAMP. GROUNDING ELECTRODE CONDUCTORS SHALL BE NO LESS THAN #8 AWG AND NO GREATER THAN#8 AWG COPPER AND BONDED TO THE EXISTING GROUNDING ELECTRODE TO PROVIDE OR A COMPLETE GROUND.

EACH MODULE WILL BE GROUNDED USING THE SUPPLIED GROUNDING POINTS IDENTIFIED BY THE MANUFACTURER.

EXPOSED NON-CURRENT CARRYING METAL PARTS OF MODULE FRAMES, EQUIPMENT, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE WITH CEC 250.134 OR 250.136(A) REGARDLESSOF VOLTAGE.

PROPER ACCESS AND WORKING CLEARANCE AROUND EXISTING AND PROPOSED ELECTRICAL EQUIPMENT WILL BE PROVIDED PER CEC 110.26.

ALL SIGNAGE WILL BE INSTALLED AS REQUIRED BY THE CEC.

HEIGHT OF INTEGRATED AC/DC DISCONNECT SHALL NOT EXCEED 6' 7" PER CEC 240.24.

THE GROUNDING ELECTRODE CONDUCTOR SHALL BE PROTECTED FROM PHYSICAL DAMAGE BETWEEN THE GROUNDING ELECTRODE AND THE PANEL (OR INVERTER) IF SMALLER THAN #6 AWG COPPERWIRE PER CEC 250.64(B). THE GROUNDING ELECTRODE CONDUCTOR WILL BE CONTINUOUS, EXCEPT FOR SPLICES OR JOINTS AT BUSBARS WITHIN LISTED EQUIPMENT PER CEC 250.64(C).

ALL EXTERIOR CONDUIT SHALL BE PAINTED TO MATCH ADJACENT SURFACES.

THE PV CONNECTION IN THE PANEL BOARD SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END FROM THE INPUT FEEDER LOCATION OR MAIN CIRCUIT LOCATION PER CEC 705.12 (B)(2)(3)(b).

SITE CONDITIONS SHALL PREVAIL IF NO SCALE IS GIVEN. DRAWINGS ARE NOT NECESSARILY TO SCALE. ALL DIMENSIONS SHALL BE VERIFIED BY SUBCONTRACTOR UPON COMMENCEMENT OFCONSTRUCTION.

PER THE CA RESIDENTIAL CODE (CRC) § R314 & R315, 10 YEAR BATTERY CARBON MONOXIDE AND SMOKE ALARMS SHALL BE INSTALLED IN EACH SLEEPING AREA AND HALLWAYS LEADING TO SLEEPINGAREAS.

WIRELESS

SYSTEM INFORMATIONSYSTEM SIZEPV MODULES

RACKINGINVERTER(S)

ECOFASTEN CLICK-FIT

SHEET INDEXIE-01IE-02IE-03IE-04

TITLE SHEET

MOUNTING LAYOUTELECTRICAL DIAGRAM

IE-05 LABELING

APPLICABLE CODES

LEGEND

SCOPE OF WORK

MOUNTING

EXISTING BUILDING INFORMATIONSTRUCTURE TYPE: RESIDENTIAL OCCUPIED BUILDINGROOF FRAMING: 2"X4" TRUSSES, 24" O.C.ROOF TYPE:STORIES: 2

CONSTRUCTION NOTES

M METER

INVERTER

GROUND

SWITCH

BREAKER

FUSE

CONDUIT RUN

VICINITY MAP

FLAT TILE

9 LONGI: LR4-60HPH-350M 9 ENPHASE IQ7-60-2-US

ECOFASTEN CLICK-FIT

3.150 kW DC / 3.055 kW AC

PROJECT INFORMATION

AHJ SIGNATURE AND DATE

SHEET TITLE

SHEET NUMBER

Infinity Energy3855 Atherton RdRocklin, CA 95765T:(888)-244-2513

[email protected]#: 998627

MICHAEL CARLSON

5343 CORMORANT CT.

JURUPA VALLEY

CA, 91752

SUNNOVA

CITY OF JURUPA VALLEY

DRAWN BY:

DATE:

NAME:

ADDRESS:

CITY:

STATE, ZIP:

AHJ:

FINANCE TYPE:

R. KOPBAYEV

8/23/2021

TITLE SHEET

IE-01

160-474-005APN#:

SITE PLAN

INSTALLATION CONSISTS OF 9 LONGI: LR4-60HPH-350M PV MODULES,9 MICRO INVERTERS AND RELATED ELECTRICAL METERING (IF USED)AND SAFETY EQUIPMENT.

ALL COMPONENTS ARE UL LISTED AND CEC CERTIFIED, WHEREWARRANTED

ALL EQUIPMENT WILL BE INSTALLED AS REQUIRED BY APPLICABLECODES AND LOCAL UTILITY COMPANY REQUIREMENTS.

AIR CONDITIONER

CHIMNEY

A/C

DESIGN CRITERIA

WIND SPEED: 110 MPH

WIND EXPOSURE: C

SNOW LOAD: 0 PSF

C7.8

R. Kopbayev

2019 CALIFORNIA ELECTRICAL CODE (CEC)2019 CALIFORNIA BUILDING CODE (CBC)2019 CALIFORNIA RESIDENTIAL CODE (CRC)2019 PLUMBING CODE2019 MECHANICAL CODE2019 FIRE CODE2019 ENERGY CODE

DRIVEWAY

CO

RM

OR

ANT

CO

UR

T

INFI

NIT

Y EN

ERG

Y38

55 A

THER

TON

RD

RO

CKL

IN, C

A 95

765

T:(8

88)-2

44-2

513

CSL

B#: 9

9862

7

PRO

JEC

T IN

FOR

MAT

ION

MIC

HAE

L C

ARLS

ON

5343

CO

RM

OR

ANT

CT.

JUR

UPA

VAL

LEY

CA,

917

52

AHJ:

CIT

Y O

F JU

RU

PA V

ALLE

YFI

NAN

CE

TYPE

: SU

NN

OVA

DAT

E:8/

23/2

021

LEGEND:3' SETBACK

18" SETBACK Scale:1" = 10'

SITE

PLA

N

IE

-02

FLAT TILE

COORDINATES:(33.988155, -117.543431)

R. Ko

pbay

ev

R324.6.2 - PROVING ARRAYS TAKELESS THAN 33% OF TOTAL ROOFAREA.WHEN THE ARRAYS TAKE LESSTHAN 33% WE CAN JUSTIFY AN 18"SETBACK ON BOTH SIDES OF THERIDGE. WHEN IT TAKES MORE THAN33% OF THE ROOF AREA WE MUSTUSE A 3' SETBACK ON BOTH SIDES OFTHE RIDGE.TOTAL ROOF AREA:3250 sqft

AREA OF ARRAYS:3'-5" x 5'-10" ( PANEL DIMENSIONS)40.92" x 69.84" = 19.85 sqft

panel

19.85 sqftpanel X 9 panels = 178.62 sqft

(TOTAL PANEL AREA)

PERCENTAGE OF TOTAL ROOF AREA:(178.62 sqft / 3250 sqft)(100)= 5.50%

∴ THE PANELS USE 5.50% OF THETOTAL ROOF AREA

AZIMUTH AND SLOPEMOUNTING PLANE

AZIMUTH

MP1

MODULE COUNT

MP2 MP3

2

24

4

20

3

22

180180270

TILT (degrees)

MP2

MP3

MP1

SHED (NO ELECTRICAL)

MAIN HOUSE (CONTAINS ELECTRICAL CIRCUITS)

(E) 15 LG320E1K-A5PV MODULES

KNIFEBLADE AC DISCONNECT

(E) KNIFEBLADE AC DISCONNECT

(E) COMBINER BOX

LOAD CENTER

MAIN SERVICE PANEL

COMBINER BOX

(E) LOAD CENTER

PATIO COVER(NO ELECTRICAL)

PATIO COVER(NO ELECTRICAL)

EXTERNAL 3 4" CONDUIT

JUNCTION BOX

2"X4" TRUSSES, 24" O.C.

INFI

NIT

Y EN

ERG

Y38

55 A

THER

TON

RD

RO

CKL

IN, C

A 95

765

T:(8

88)-2

44-2

513

CSL

B#: 9

9862

7

PRO

JEC

T IN

FOR

MAT

ION

MIC

HAE

L C

ARLS

ON

5343

CO

RM

OR

ANT

CT.

JUR

UPA

VAL

LEY

CA,

917

52

AHJ:

CIT

Y O

F JU

RU

PA V

ALLE

YFI

NAN

CE

TYPE

: SU

NN

OVA

DAT

E:8/

23/2

021

Scale: 1" = 10'

MO

UN

TIN

G L

AYO

UT

IE-0

3

R. Ko

pbay

ev

ROOF FRAMING DETAILScale: 1/8" = 1'

TILE ROOFING

PREMANUFACTURED GANGNAILTYPE TRUSS AT 24" ON CENTER.

9' MAX SPANPANELS

34" PLYWOOD DECKING

ROOF ATTACHMENT DETAILScale: 1" = 1'

6" Max

34"PLYWOOD

516" x 4" LAG WITH SEALER

1 PER TILE HOOK(MIN EMBEDMENT 3")

CLICKFIT TILE HOOK SUB FLASHING WITH SEALANT AND REINFORCING FABRIC

SPACING OF HOOK TILE MOUNTS ARE 4' MAXIMUMECOFASTEN CLICKFIT SYSTEM

RACKING RAIL (TYP)

ROOF ATTACHMENT (TYP)4' MAX SPAN

ENGINEERED FOR 110 MPHWINDS AND EXPOSURE C

R.Ko

pbay

ev

INFI

NIT

Y EN

ERG

Y38

55 A

THER

TON

RD

RO

CKL

IN, C

A 95

765

T:(8

88)-2

44-2

513

CSL

B#: 9

9862

7

PRO

JEC

T IN

FOR

MAT

ION

MIC

HAE

L C

ARLS

ON

5343

CO

RM

OR

ANT

CT.

JUR

UPA

VAL

LEY

CA,

917

52

AHJ:

CIT

Y O

F JU

RU

PA V

ALLE

YFI

NAN

CE

TYPE

: SU

NN

OVA

DAT

E:8/

23/2

021

ELEC

TRIC

AL D

IAG

RAM

IE-0

4

NOTE ON CONDUITALL CONDUIT SHALL BE EMT3/4" IN DIAMETER, UNLESSOTHERWISE SPECIFIED

(E) CONDUCTORS

BRANCH OF 9 PANELS

3

J-BOX

GDC Equipment GroundingConductor per CEC 690.43#6 BARE COPPER

ENPHASE Q CABLE2 Conductor

Type: THWN-2UL3003, DG CABLE

2

CONTINUOUS GROUNDING

G

LOAD CENTER

5

(N) SUB OCPDSIZE: 40A

(E) SOLAR OCPDSIZE: 20A

SOLAR OCPD

OUTPUT PER MICROINVERTER240W / 240V = 1.00ATOTAL OUTPUT9 MICROINVERTERS9*1.00A = 9.00ACONTINUOUS LOAD RULE 125%9.00A*1.25 = 11.25A∴ BREAKER SIZE 20A

MODULE MODULEMODULEMODULE

CEC 690.12 RAPIDSHUTDOWN COMPLIANT

1 TYP.

G

ENVOY

20A SOLAROCPD (2P)

4MONITOR15A OCPD

CELLMODEM

AC DISCONNECT

G

AC DISCONNECTAC DISCONNECT

G

6(E) LOADS

MAIN PANEL BUSSize: 225A

MAIN OCPDSize:200A

MG

BUILDINGGROUNDINGELECTRODE

BOTTOM FEDMAIN SERVICE

PANEL

8Meter #: 222013-411413

7

A >7/8"N/AQ-CABLE FREE AIR

B >7/8"(2) #10 AWG (90°C Cu) = 40A .91 2 CONDUCTORS 40A* 1 *.91 = 36.4A 35.0A 3/4" EMT

20.0A

35.0A 1

36°C

36°C

#6 AWG (Cu)

#8 AWG (Cu)

N/A .911 36°C(3) #10 AWG (90°C Cu) = 40A 40A* 1 *.91 = 36.4A 35.0A 35.0A C 3/4" EMT2 CONDUCTORS #8 AWG (Cu)

N/A .911 36°C(3) #8 AWG (90°C Cu) = 55A 55A* 1 *.91 = 50.0A 50.0A 50.0A D 3/4" EMT2 CONDUCTORS #8 AWG (Cu)

N/A N/AN/AN/A

DESCRIPTIONOBJ

.

COMPONENT

# OF CURRENTCARRYING

CONDUCTORSELEC

.TAG

CONDUCTOR CONDUCTORTEMPERATURE DERATING

CORRECTEDAMPACITY

HEIGHTABOVEROOF

AMBIENTTEMP (°C)

AMPACITYCORRECTION310.15(B)(2)(a)

AMP CORR310.15(B)(3)(a)

ORIG.AMPS

TEMPDER.

CCC DER.

CORR.AMPS* * =

CONDUITSIZE

MAXAMPSFOR A75°C

RATEDTERMINAL

90°C RATED THWN-2 @30°C PER 310.15(B)(16) &

310.15(B)(17)

CONDUIT CONDUCTORCOUNT ADJ FACTOR USABLE

AMPS

GROUNDINGWIRE SIZE =MAX OCPD

(PROTECTEDUNLESSSTATED)(# OF WIRES INCLUDING NEUTRAL

IF APPLICABLE)

9 ENPHASE IQ7-60-2-US WITH RAPID SHUTDOWN

(N) J-BOX

(N) BRANCH OF MICROINVERTERS IN PARALLEL

9 LONGI: LR4-60HPH-350M

1

2 JUNCTION BOX

3 (N) SOLAR PV MODULES

4 (N) COMBINER BOX COMBINER BOX W/ ENPHASE ENVOY-IQ / CELL MODEM: MTC-H5-B03

5

6

(E) SCE UTILITY METER SCE UTILITY METER: #222013-411413

(E) MAIN ELECTRICAL SERVICE PANEL 225A RATED, 240V, 2P, WITH 200A MAIN BREAKER7

(N) AC DISCONNECT 60A NON-FUSIBLE - DG222URB

B

D

A

PV MODULES 15 LG320E1K-A5

INVERTERS 15 ENPHASE IQ6PLUS

EXISTING SOLAR SYSTEM SIZE: 4.8 kW DC

AC DISCONNECT 30A NON-FUSIBLE - DG221URB

COMBINER BOX ENPHASE COMBINER

8

(N) LOAD CENTER EATON 125A

C

D

THIS SYSTEM CONTAINSNO DC POWER LOADS RELOCATED

OVER 6' WILL REQUIREAFCI PROTECTION

INFI

NIT

Y EN

ERG

Y38

55 A

THER

TON

RD

RO

CKL

IN, C

A 95

765

T:(8

88)-2

44-2

513

CSL

B#: 9

9862

7

PRO

JEC

T IN

FOR

MAT

ION

MIC

HAE

L C

ARLS

ON

5343

CO

RM

OR

ANT

CT.

JUR

UPA

VAL

LEY

CA,

917

52

AHJ:

CIT

Y O

F JU

RU

PA V

ALLE

YFI

NAN

CE

TYPE

: SU

NN

OVA

DAT

E:8/

23/2

021

LABE

LIN

G

IE

-05

LABELING NOTES1. LABELING REQUIREMENTS BASED ON THE CALIFORNIA ELECTRICAL CODE, INTERNATIONAL FIRE CODE 605.11, OSHA STANDARD1910.145, CCR TITLE 8 §3340, ANSI Z535.4-20112. MATERIAL BASED ON THE REQUIREMENTS OF THE AUTHORITY HAVING JURISDICTION.3. LABELS TO BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED.4. LABELS TO BE A MINIMUM LETTER HEIGHT OF 3/8" AND PERMANENTLY AFFIXED.5. ALERTING WORDS TO BE COLOR CODED. "DANGER" WILL HAVE RED BACKGROUND; "WARNING" WILL HAVE ORANGE BACKGROUND;"CAUTION" WILL HAVE YELLOW BACKGROUND.[ANSI Z535.4-2011]

DIRECTORYA PERMANENT PLAQUE OR DIRECTORY PROVIDING THE LOCATION OF ALL ELECTRICPOWER SOURCE DISCONNECTING MEANS SHALL BE PROVIDED AT EACH SERVICEEQUIPMENT LOCATION AND PV SYSTEM DISCONNECTING MEANS IN ACCORDANCEWITH CEC 705.10. PV SYSTEM EQUIPMENT AND DISCONNECTING MEANS SHALL NOT BEINSTALLED IN BATHROOMS [CEC 690.4(E)]

AT RAPID SHUTDOWN SYSTEM[CEC 690.56(C)(1)(A)]

LABEL 1

WARNING: PHOTOVOLTAICPOWER SOURCE

AT EXPOSED RACEWAYS, CABLE TRAYS, AND OTHER WIRINGMETHODS; SPACED AT MAXIMUM 10FT SECTION OR WHERESEPARATED BY ENCLOSURES, WALLS, PARTITIONS,CEILINGS, OR FLOORS. [CEC 690.31(G)(3)]

LABEL 5

LABELINGLETTERING TO BE AT LEAST 3 8" WHITEON RED BACKGROUND; REFLECTIVE, UVRESISTANT STICKERS. [CEC 690.31(G)(4)]

RATED AC OUTPUT CURRENT: 9.00A NOMINAL OPERATING AC VOLTAGE: 240V

LABEL 2AT EACH AC DISCONNECTING MEANS[CEC 690.13(B) AND 690.54]

PHOTOVOLTAICAC DISCONNECT

RAPID SHUTDOWN SWITCHFOR SOLAR PV SYSTEM

AT RAPID SHUTDOWN SWITCH[CEC 690.56(C)(3)]

LABEL 7

R. Ko

pbay

ev

LABEL 4

LABEL 6AT POINT OF INTERCONNECTIONOVERCURRENT DEVICE[CEC 705.12(B)(2)(3)(B)]

AT MAIN SERVICE PANEL, PULL BOXES[CEC 705.12(B)(3)]

POWER SOURCE OUTPUTCONNECTION - DO NOT RELOCATE

THIS OVERCURRENT DEVICE

WARNING

PHOTOVOLTAIC SYSTEMCIRCUIT IS BACKFED

CAUTION

5343 CORMORANT CT.N

CAUTIONPOWER TO THIS BUILDING ISALSO SUPPLIED FROM THE

FOLLOWING SOURCE(S) WITHDISCONNECTS LOCATED AS

SHOWN.

INSTALLED BY:INFINITY ENERGY INC.(916) 474-4723

LOAD CENTERMAIN SERVICE PANEL

COMBINER BOX

LOAD CENTER(INSIDE)

COMBINER BOXKNIFEBLADE AC DISCONNECTKNIFEBLADE AC DISCONNECT

The Enphase IQ Combiner 3C™ with

Enphase IQ Envoy™ and integrated LTE-M cell

modem with 5-year data plan consolidates

interconnection equipment into a single

enclosure and streamlines PV and storage

installations by providing a consistent, pre-

wired solution for residential applications.

It offers up to four 2-pole input circuits and

Eaton BR series busbar assembly.

Enphase IQ Combiner 3C(X-IQ-AM1-240-3C)

To learn more about Enphase offerings, visit enphase.com

Data SheetEnphase Networking

Smart

• Includes IQ Envoy for communication and control

• Includes LTE-M cell modem and 5-year data plan• Flexible networking supports Wi-Fi,

Ethernet, or cellular• Optional AC receptacle available for PLC bridge• Provides production metering and optional

consumption monitoring

Simple

• Reduced size from previous combiner• Centered mounting brackets support single

stud mounting• Supports back and side conduit entry• Up to four 2-pole branch circuits for 240 VAC

plug-in breakers (not included)• 80 A total PV or storage branch circuits

Reliable

• DurableNRTL-certifiedNEMAtype 3R enclosure

• Five-year limited warranty• UL listed

To learn more about Enphase offerings, visit enphase.com© 2019 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Combiner 3C, and other trademarks or service names are the trademarks of Enphase Energy, Inc. 2019-11-04

MODEL NUMBER

IQ Combiner 3C X-IQ-AM1-240-3C

IQ Combiner 3C with Enphase IQ Envoy™ printed circuit board for integrated revenue grade PV production metering (ANSI C12.20 +/- 0.5%) and optional* consumption monitoring (+/- 2.5%).IncludesEnphaseMobileConnectLTE-Mcellmodemandfive-yeardataplan.Aplug-and-playindustrial-grade cellular modem with data plan for systems up to 60 microinverters. (Available in the US, Canada, Mexico, Puerto Rico, and the US Virgin Islands, where there is adequate cellular service in the installation area.)

ACCESSORIES and REPLACEMENT PARTS (not included, order separately)

Consumption Monitoring* CTCT-200-SPLIT

Split core current transformers enable whole home consumption metering (+/- 2.5%).

* Consumption monitoring is required for Enphase Storage Systems

Wireless USB adapterCOMMS-KIT-01

Installed at the IQ Envoy. For communications with Enphase Encharge™ storage and Enphase Enpower™ smart switch. Includes USB cable for connection to IQ Envoy or Enphase IQ Combiner™ and allows redundant wireless communication with Encharge and Enpower.

Circuit Breakers BRK-10A-2-240 BRK-15A-2-240 BRK-20A-2P-240

Supports Eaton BR210, BR215, BR220, BR230, BR240, BR250, and BR260 circuit breakers.Circuit breaker, 2 pole, 10A, Eaton BR210 Circuit breaker, 2 pole, 15A, Eaton BR215Circuit breaker, 2 pole, 20A, Eaton BR220

EPLC-01 Power line carrier (communication bridge pair), quantity - one pair

XA-PLUG-120-3 Accessory receptacle for Power Line Carrier in IQ Combiner 3C (required for EPLC-01)

XA-ENV-PCBA-3 Replacement IQ Envoy printed circuit board (PCB) for Combiner 3C

ELECTRICAL SPECIFICATIONS

Rating Continuous duty

System voltage 120/240 VAC, 60 Hz

Eaton BR series busbar rating 125 A

Max. continuous current rating (output to grid) 65 A

Max. fuse/circuit rating (output) 90 A

Branch circuits (solar and/or storage) Up to four 2-pole Eaton BR series Distributed Generation (DG) breakers only (not included)

Max. continuous current rating (input from PV) 64 A

Max. total branch circuit breaker rating (input) 80A of distributed generation / 90A with IQ Envoy breaker included

Production Metering CT 200 A solid core pre-installed and wired to IQ Envoy

MECHANICAL DATA

Dimensions (WxHxD) 37.5 x 49.5 x 16.8 cm (14.75” x 19.5” x 6.63”). Height is 21.06" (53.5 cm) with mounting brackets.

Weight 7.5 kg (16.5 lbs)

Ambient temperature range -40º C to +46º C (-40º to 115º F)

Cooling Natural convection, plus heat shield

Enclosure environmental rating Outdoor,NRTL-certified,NEMAtype3R,polycarbonateconstruction

Wire sizes • 20 A to 50 A breaker inputs: 14 to 4 AWG copper conductors• 60 A breaker branch input: 4 to 1/0 AWG copper conductors• Main lug combined output: 10 to 2/0 AWG copper conductors• Neutral and ground: 14 to 1/0 copper conductorsAlways follow local code requirements for conductor sizing.

Altitude To 2000 meters (6,560 feet)

INTERNET CONNECTION OPTIONS

Integrated Wi-Fi 802.11b/g/n

Cellular CELLMODEM-M1 (4G based LTE-M)

Ethernet Optional, 802.3, Cat5E (or Cat 6) UTP Ethernet cable (not included)

COMPLIANCE

Compliance, Combiner UL 1741, CAN/CSA C22.2 No. 107.1, 47 CFR, Part 15, Class B, ICES 003Production metering: ANSI C12.20 accuracy class 0.5 (PV production)

Compliance, IQ Envoy UL 60601-1/CANCSA 22.2 No. 61010-1

Enphase IQ Combiner 3C

The high-powered smart grid-ready Enphase IQ 7 Micro™ and Enphase IQ 7+ Micro™ dramatically simplify the installation process while achieving the highest system efficiency.

Part of the Enphase IQ System, the IQ 7 and IQ 7+ Microinverters integrate with the Enphase IQ Envoy™, Enphase IQ Battery™, and the Enphase Enlighten™ monitoring and analysis software.

IQ Series Microinverters extend the reliability standards set forth by previous generations and undergo over a million hours of power-on testing, enabling Enphase to provide an industry-leading warranty of up to 25 years.

Enphase IQ 7 and IQ 7+Microinverters

To learn more about Enphase offerings, visit enphase.com

Data SheetEnphase MicroinvertersRegion: AMERICAS

Easy to Install

• Lightweight and simple• Faster installation with improved, lighter two-wire cabling• Built-in rapid shutdown compliant (NEC 2014 & 2017)

Productive and Reliable

• Optimized for high powered 60-cell and 72-cell* modules• More than a million hours of testing• Class II double-insulated enclosure• UL listed

Smart Grid Ready

• Complies with advanced grid support, voltage and frequency ride-through requirements

• Remotely updates to respond to changing grid requirements

• Configurableforvaryinggridprofiles• Meets CA Rule 21 (UL 1741-SA)

* The IQ 7+ Micro is required to support 72-cell modules.

1. No enforced DC/AC ratio. See the compatibility calculator at https://enphase.com/en-us/support/module-compatibility. 2. Nominal voltage range can be extended beyond nominal if required by the utility.3. Limits may vary. Refer to local requirements to define the number of microinverters per branch in your area.

To learn more about Enphase offerings, visit enphase.com© 2018 Enphase Energy. All rights reserved. All trademarks or brands used are the property of Enphase Energy, Inc. 2018-05-24

INPUT DATA (DC) IQ7-60-2-US / IQ7-60-B-US IQ7PLUS-72-2-US / IQ7PLUS-72-B-USCommonly used module pairings¹ 235 W - 350 W + 235 W - 440 W +Module compatibility 60-cell PV modules only 60-cell and 72-cell PV modulesMaximum input DC voltage 48 V 60 VPeak power tracking voltage 27 V - 37 V 27 V - 45 VOperating range 16 V - 48 V 16 V - 60 VMin/Max start voltage 22 V / 48 V 22 V / 60 VMax DC short circuit current (module Isc) 15 A 15 AOvervoltage class DC port II IIDC port backfeed current 0 A 0 APVarrayconfiguration 1 x 1 ungrounded array; No additional DC side protection required;

AC side protection requires max 20A per branch circuitOUTPUT DATA (AC) IQ 7 Microinverter IQ 7+ MicroinverterPeak output power 250 VA 295 VAMaximum continuous output power 240 VA 290 VANominal (L-L) voltage/range² 240 V /

211-264 V208 V / 183-229 V

240 V / 211-264 V

208 V / 183-229 V

Maximum continuous output current 1.0 A (240 V) 1.15 A (208 V) 1.21 A (240 V) 1.39 A (208 V)Nominal frequency 60 Hz 60 HzExtended frequency range 47 - 68 Hz 47 - 68 HzAC short circuit fault current over 3 cycles 5.8 Arms 5.8 ArmsMaximum units per 20 A (L-L) branch circuit³ 16 (240 VAC) 13 (208 VAC) 13 (240 VAC) 11 (208 VAC)Overvoltage class AC port III IIIAC port backfeed current 0 A 0 APower factor setting 1.0 1.0Power factor (adjustable) 0.7 leading ... 0.7 lagging 0.7 leading ... 0.7 laggingEFFICIENCY @240 V @208 V @240 V @208 VPeakCECefficiency 97.6 % 97.6 % 97.5 % 97.3 %CECweightedefficiency 97.0 % 97.0 % 97.0 % 97.0 %

MECHANICAL DATAAmbient temperature range -40ºC to +65ºCRelative humidity range 4% to 100% (condensing)Connector type (IQ7-60-2-US & IQ7PLUS-72-2-US) MC4 (or Amphenol H4 UTX with additional Q-DCC-5 adapter)Connector type (IQ7-60-B-US & IQ7PLUS-72-B-US) Friends PV2 (MC4 intermateable).

Adaptors for modules with MC4 or UTX connectors:- PV2 to MC4: order ECA-S20-S22- PV2 to UTX: order ECA-S20-S25

Dimensions (WxHxD) 212 mm x 175 mm x 30.2 mm (without bracket)Weight 1.08 kg (2.38 lbs)Cooling Natural convection - No fansApproved for wet locations YesPollution degree PD3Enclosure Class II double-insulated, corrosion resistant polymeric enclosureEnvironmental category / UV exposure rating NEMA Type 6 / outdoorFEATURESCommunication Power Line Communication (PLC)Monitoring Enlighten Manager and MyEnlighten monitoring options.

Both options require installation of an Enphase IQ Envoy.Disconnecting means The AC and DC connectors have been evaluated and approved by UL for use as the load-break

disconnect required by NEC 690.Compliance CA Rule 21 (UL 1741-SA)

UL 62109-1, UL1741/IEEE1547, FCC Part 15 Class B, ICES-0003 Class B, CAN/CSA-C22.2 NO. 107.1-01 This product is UL Listed as PV Rapid Shut Down Equipment and conforms with NEC-2014 and NEC-2017 section 690.12 and C22.1-2015 Rule 64-218 Rapid Shutdown of PV Systems, for AC and DC conductors, when installed according manufacturer’s instructions.

Enphase IQ 7 and IQ 7+ Microinverters

 

 

pe.eaton.com

 

 

 

Eaton general duty non-fusiblesafety switchDG222URB

UPC:782113144238

Dimensions:Height: 14.38 IN●

Length: 7.38 IN●

Width: 8.69 IN●

Weight:9 LB

Notes:WARNING! Switch is not approved forservice entrance unless a neutral kit is installed.

Warranties: Eaton Selling Policy 25-000, one (1) year fromthe date of installation of the Product oreighteen (18) months from the date of shipmentof the Product, whichever occurs first.

Specifications:Type: Non-fusible, single-throw●

Amperage Rating: 60A●

Enclosure: NEMA 3R, Rainproof●

Enclosure Material: Painted galvanized steel●

Fuse Configuration: Non-fusible●

Number Of Poles: Two-pole●

Number Of Wires: Two-wire●

Product Category: General duty safety switch●

Voltage Rating: 240V●

Supporting documents:Eatons Volume 2-Commercial Distribution●

Eaton Specification Sheet - DG222URB●

Certifications: UL Listed●

Product compliance: No Data

 

 

pe.eaton.com

 

 

 

BR style 1-inch loadcenterBR816L125RP

UPC:786676001472

Dimensions:Height: 13 IN●

Length: 3.56 IN●

Width: 11 IN●

Warranties: 10 year●

Specifications:Special Features: Current design●

Type: Main lug●

Amperage Rating: 125A●

Box Size: 7r●

Bus Material: Aluminum●

Cover: Cover included●

Enclosure: NEMA 3R●

Enclosure Material: Metallic●

Interrupt Rating: 10 kAIC●

Main Circuit Breaker: BR●

Number Of Circuits: 16●

Number Of Spaces: 8●

Number Of Wires: Three-wire●

Phase: Single-phase●

Voltage Rating: 120/240V●

Wire Size: #14-1 AWG Cu/Al●

Supporting documents:Eatons Volume 1-Residential and LightCommercial

Cutler-Hammer Type CH and BR Loadcenters -Instructions

Type BR Arc Fault Circuit Breakers andLoadcenters

Eaton Specification Sheet - BR816L125RP●

Certifications: UL 67●

 UL 50●

Product compliance: No Data

______________________________________________________________________

© 2016 Eaton. All rights reserved.

CANTEX INC. | 301 Commerce Street, Suite 2700, Fort Worth, TX 76102 | 817.215.7000 | www.cantexinc.com

Junction Box

PVC Junction Boxes

Part Number

Trade Size

DescriptionCarton

Qty.

Junction Box Base CoverScrews

“A” “B” “C” “D” “E” “F” “G” “H” “J” “K” “A” “B” “C” “D”

51337051

4x4x2 Molded 10 2.000 2.150 5.375 4.400 4.400 4.000 4.000 .250 .125 .160 .240 .370 4.375 4.375 #8 x 1/2”

51337091

4x4x4 Molded 10 4.000 4.150 5.375 4.400 4.400 4.000 4.000 .250 .188 .160 .240 .700 4.375 4.375 #8 x 1/2”

51337071

4x4x6 Molded 10 6.000 6.150 5.375 4.400 4.400 4.000 4.000 .250 .188 .160 .240 .370 4.375 4.375 #8 x 1/2”

51337061

5x5x2 Molded 10 2.000 2.170 6.375 5.375 5.375 5.000 5.000 .250 .188 .170 .180 .267 5.375 5.375 #8 x 1/2”

51337101

6x6x4 Molded 10 4.000 4.200 7.375 6.438 6.438 6.000 6.000 .250 .188 .220 .180 .350 6.750 6.750 #8 x 1/2”

51337111

6x6x6 Molded 5 6.000 6.250 7.375 6.438 6.438 6.000 6.000 .250 .188 .220 .180 .350 6.750 6.750 #8 x 1/2”

51337121

8x8x4 Molded 5 4.000 4.250 9.375 8.625 8.625 8.000 8.000 .250 .188 .220 .180 .350 9.000 9.000 #10 x 3/4”

51331641

8x8x6 Molded 4 6.000 6.250 9.375 8.625 8.625 8.000 8.000 .250 .188 .220 .180 .350 9.000 9.000 #10 x 3/4”

51337081

8x8x7 Molded 4 7.000 7.250 9.375 8.625 8.625 8.000 8.000 .250 .188 .220 .180 .350 9.000 9.000 #10 x 3/4”

51337141

12x12x4 Molded 2 4.000 4.250 13.625 12.625 12.625 11.875 11.875 .250 .188 .220 .220 .437 13.000 13.000 #10 x 3/4”

51337131

12x12x6 Molded 2 6.000 6.250 13.750 12.625 12.625 11.875 11.875 .250 .188 .220 .220 .437 13.000 13.000 #10 x 3/4”

*5133176 12x12x12 Fab 1 -- -- -- -- -- -- -- -- -- -- -- -- -- -- --

**5133163 16x14x6 Molded 1 6.00 6.250 16.000 14.875 16.875 16.435 14.435 .220 .125 .220 .214 .500 17.125 17.125 #10 x 3/4”

*5133167 18x18x6 Fab 1 -- -- -- -- -- -- -- -- -- -- -- -- -- -- --

*5133165 24x18x8 Fab 1 -- -- -- -- -- -- -- -- -- -- -- -- -- -- --

*5133161 24x18x12 Fab 1 -- -- -- -- -- -- -- -- -- -- -- -- -- -- --

*5133177 24x24x6 Fab 1 -- -- -- -- -- -- -- -- -- -- -- -- -- -- --

*5133166 24x24x8 Fab 1 -- -- -- -- -- -- -- -- -- -- -- -- -- -- --

*5133173 36x24x8 Fab 1 -- -- -- -- -- -- -- -- -- -- -- -- -- -- --

Dimensions are nominal * Not UL Listed - 4X NEMA Rating

** UL Listed with only a Type 1 NEMA Rating

Fabricated Junction Box

UL Catagory - QCUP UL File #E205935 Control #92CM

1. NEMA Ratings for Types, 1, 3, 3S, 4, 4X, 5, 6, and 6P

Junction Boxes are designed to support electrical devices and fixtures. They also provide necessary protection for wires and terminals.

• Material is Rigid PVC• Neoprene gasket with

zinc plated steel screws• UL Listed, UL Marine

Listed• Made in USA

• Material is Rigid PVC• Neoprene gasket with

zinc plated steel screws• Fully gasketed cover• Made in USA• See certifications below

Molded Junction Box

1

2

44

3

6 7

89

10

5

ITEM DESCRIPTION SKU(S)

1 GREENFASTEN FLASHING GF1M-810-GAL-BLK, GF1-810-GAL-MIL

2 CLICKFIT L-FOOT ASSEMBLY 1500004

3 CLICKFIT TILE HOOK ASSEMBLY 1500005

4 SS LAG BOLT AND EPDM BONDED WASHER, 5/16 X 4 IN LONG POLY KIT LAG4/W-50CT

5 ROOFING SCRW #15 X 2 IN DRILL PT SCRW DP 15-13X02

6 CLICKFIT RAIL 1500033, 1500034, 1500035

7 CLICKFIT RAIL SPLICE 1008061

8 CLICKFIT MIDCLAMP ASSEMBLY 1510011, 1510012

9 CLICKFIT END CLAMP ASSEMBLY 1510016, 1510017, 1510018, 1510019, 1510020, 1510021

10 CLICKFIT END CAP 1510041

ITEM NO. PART NUMBER DESCRIPTION QTY.

1 750044 (REV 01) 1

2 701043 (REV 06) 1

3 701044 (REV 02) 1

4 750002-04 (REV 02) SS LAG BOLT AND EPDM WASHER, 5/16-9 X 4.00 IN LONG 2

5 150040-01 16 450006-08 17 201017 Rail coupler 1

8 750043-01 (REV 02) 1

9 750054 (REV 04) 110 301033 End Cap Grey 1

REVISION

DESCRIPTION

PRODUCT

DO NOTSCALE 1 OF 11A3800042

CLICK FIT SYSTEM CUT SHEET

SHEETSHEET SIZE

A. MORANO T. RAY 1/24/2020DRAWN BY APPROVED BY DATE

01DRAWING NUMBER

C COPYRIGHT ECOFASTEN SOLAR, ALL RIGHTS RESERVED. THE INFORMATION DISCLOSED HEREIN IS DEEMED TO BE CONFIDENTIAL, PROPRIETARY, AND A TRADE SECRET OF ECOFASTEN SOLAR. THIS INFORMATION MAY NOT BE USED, REPRODUCED, OR DISCLOSED WITHOUT THE EXPRESSED WRITTEN CONSENT OF ECOFASTEN SOLAR.

THIRD ANGLE PROJECTION

A A

B B

C C

D D

E E

F F

8

8

7

7

6

6

5

5

4

4

3

3

2

2

1

1

DIMENSIONS ARE IN INCHES

CLICKFIT SYSTEM

1

2

5

4 6

3

6.6

9.6

DATE OF MANUFACTURE

1/2 IN HEX

1/2 IN HEX

8.7 5.6

0.24

0.73

0.35 1.0

2.3 3.2

1.8

6.2

1.5

2.0

1.0

7.7

SIDE VIEW

TOP VIEW

FRONT VIEW

SIDE VIEW (EXPLODED)

ISO VIEW

ITEM DESCRIPTION MATERIAL

1 CLICKFIT TILE HOOK BASE POSMAC (COATED STEEL)

2 CLICKFIT CLICKER POSMAC (COATED STEEL)

3 HEX FLANGE BOLT, 5/16-18 UNC X 0.5 IN, GREY COATED STEEL W/ MAGNI COATING

4 HEX FLANGE BOLT, 5/16-18 UNC X 1.25 IN, GREY COATED STEEL W/ MAGNI COATING

5 CLICKFIT CLICKER POSMAC (COATED STEEL)

6 SQUARE NUT, 5/16-18 UNC, GREY COATED STEEL W/ MAGNI COATING

REVISION

DESCRIPTION

PRODUCT

DO NOTSCALE 4 OF 11A3800042

CLICK FIT SYSTEM CUT SHEETCLICKFIT TILE HOOK

ASSEMBLY

SHEETSHEET SIZE

A. MORANO T. RAY 1/24/2020DRAWN BY APPROVED BY DATE

01DRAWING NUMBER

C COPYRIGHT ECOFASTEN SOLAR, ALL RIGHTS RESERVED. THE INFORMATION DISCLOSED HEREIN IS DEEMED TO BE CONFIDENTIAL, PROPRIETARY, AND A TRADE SECRET OF ECOFASTEN SOLAR. THIS INFORMATION MAY NOT BE USED, REPRODUCED, OR DISCLOSED WITHOUT THE EXPRESSED WRITTEN CONSENT OF ECOFASTEN SOLAR.

THIRD ANGLE PROJECTION

A A

B B

C C

D D

E E

F F

8

8

7

7

6

6

5

5

4

4

3

3

2

2

1

1

DIMENSIONS ARE IN INCHES

1500005

0.75

0.31

4.0

1/2 IN HEX

12

SIDE VIEW (EXPLODED)

ISO VIEW

ITEM DESCRIPTION MATERIAL

1 SS LAG BOLT, 5/16 X 4.00 IN LONG 18-8 STAINLESS STEEL

2 EPDM BONDED WASHER, 5/16 18-8 STAINLESS STEEL AND EPDM

REVISION

DESCRIPTION

PRODUCT

DO NOTSCALE 5 OF 11A3800042

CLICK FIT SYSTEM CUT SHEETLAG BOLT AND BONDED

WASHER, 5/16 X 4 IN LONG

SHEETSHEET SIZE

A. MORANO T. RAY 1/24/2020DRAWN BY APPROVED BY DATE

01DRAWING NUMBER

C COPYRIGHT ECOFASTEN SOLAR, ALL RIGHTS RESERVED. THE INFORMATION DISCLOSED HEREIN IS DEEMED TO BE CONFIDENTIAL, PROPRIETARY, AND A TRADE SECRET OF ECOFASTEN SOLAR. THIS INFORMATION MAY NOT BE USED, REPRODUCED, OR DISCLOSED WITHOUT THE EXPRESSED WRITTEN CONSENT OF ECOFASTEN SOLAR.

THIRD ANGLE PROJECTION

A A

B B

C C

D D

E E

F F

8

8

7

7

6

6

5

5

4

4

3

3

2

2

1

1

DIMENSIONS ARE IN INCHES

POLY KIT LAG4/W-50CT

2.00 1.75

0.204

SELF DRILLING POINT

0.437

TOP VIEW

#3 PHILLIPS TYPE 1 RECESS

ISO VIEW

SIDE VIEW

ITEM DESCRIPTION MATERIAL

1 ROOFING SCREW, #15 X 2 IN, DRILL POINT 18-8 STAINLESS STEELSTEEL, CATHODIC EPOXY E-COAT

REVISION

DESCRIPTION

PRODUCT

DO NOTSCALE 6 OF 11A3800042

CLICK FIT SYSTEM CUT SHEETDECK SCREW

#15 X 2 IN, #3 PHILLIPS HEAD

SHEETSHEET SIZE

A. MORANO T. RAY 1/24/2020DRAWN BY APPROVED BY DATE

01DRAWING NUMBER

C COPYRIGHT ECOFASTEN SOLAR, ALL RIGHTS RESERVED. THE INFORMATION DISCLOSED HEREIN IS DEEMED TO BE CONFIDENTIAL, PROPRIETARY, AND A TRADE SECRET OF ECOFASTEN SOLAR. THIS INFORMATION MAY NOT BE USED, REPRODUCED, OR DISCLOSED WITHOUT THE EXPRESSED WRITTEN CONSENT OF ECOFASTEN SOLAR.

THIRD ANGLE PROJECTION

A A

B B

C C

D D

E E

F F

8

8

7

7

6

6

5

5

4

4

3

3

2

2

1

1

DIMENSIONS ARE IN INCHES

SCRW DP 15-13X02

L

1.50

1.57 1.18

0.762

SIDE VIEW

ISO VIEW

FRONT VIEW

X

Y

ITEM DESCRIPTION MATERIAL

1 CLICKFIT RAIL ALUMINUM

CONFIGURATION TABLE

SKU LENGTH L

1500033 83.9

1500034 124.6

1500035 165.4

RAIL SECTION PROPERTIES

PROPERTY VALUE

TOTAL CROSS-SECTIONAL AREA 0.328 IN2

MOMENT OF INERTIA (X-AXIS) 0.116 IN4

MOMENT OF INERTIA (Y-AXIS) 0.092 IN4

POLAR MOMENT OF INERTIA 0.208 IN4

REVISION

DESCRIPTION

PRODUCT

DO NOTSCALE 7 OF 11A3800042

CLICK FIT SYSTEM CUT SHEETRAIL

SHEETSHEET SIZE

A. MORANO T. RAY 1/24/2020DRAWN BY APPROVED BY DATE

01DRAWING NUMBER

C COPYRIGHT ECOFASTEN SOLAR, ALL RIGHTS RESERVED. THE INFORMATION DISCLOSED HEREIN IS DEEMED TO BE CONFIDENTIAL, PROPRIETARY, AND A TRADE SECRET OF ECOFASTEN SOLAR. THIS INFORMATION MAY NOT BE USED, REPRODUCED, OR DISCLOSED WITHOUT THE EXPRESSED WRITTEN CONSENT OF ECOFASTEN SOLAR.

THIRD ANGLE PROJECTION

A A

B B

C C

D D

E E

F F

8

8

7

7

6

6

5

5

4

4

3

3

2

2

1

1

DIMENSIONS ARE IN INCHES

SEE CONFIG TABLE

1.06

1.37

7.9

SIDE VIEW

ISO VIEW

FRONT VIEW

ITEM DESCRIPTION MATERIAL

1 CLICKFIT RAIL SPLICE MAGNELIS (COATED STEEL)

REVISION

DESCRIPTION

PRODUCT

DO NOTSCALE 8 OF 11A3800042

CLICK FIT SYSTEM CUT SHEETRAIL SPLICE

SHEETSHEET SIZE

A. MORANO T. RAY 1/24/2020DRAWN BY APPROVED BY DATE

01DRAWING NUMBER

C COPYRIGHT ECOFASTEN SOLAR, ALL RIGHTS RESERVED. THE INFORMATION DISCLOSED HEREIN IS DEEMED TO BE CONFIDENTIAL, PROPRIETARY, AND A TRADE SECRET OF ECOFASTEN SOLAR. THIS INFORMATION MAY NOT BE USED, REPRODUCED, OR DISCLOSED WITHOUT THE EXPRESSED WRITTEN CONSENT OF ECOFASTEN SOLAR.

THIRD ANGLE PROJECTION

A A

B B

C C

D D

E E

F F

8

8

7

7

6

6

5

5

4

4

3

3

2

2

1

1

DIMENSIONS ARE IN INCHES

1008061

1

2

5

4

3

1.0

0.2

0.79

0.4

1/2 IN HEX

2.0

1.6

DATE OF MANUFACTURE

SIDE VIEW

ISO VIEW

FRONT VIEW

SIDE VIEW (EXPLODED)

CONFIGURATION TABLE

SKU COMPATIBLE PANNEL HEIGHTS

1510011 30MM TO 40MM

1510012 40MM TO 50MM

ITEM DESCRIPTION MATERIAL

1 MIDCLAMP CLICKER ALUMINUM, MILL FINISH

2 MIDCLAMP TOP PLATE ALUMINUM, ANNODIZED BLACK

3 BONDING PIN STAINLESS STEEL

4 SS SQUARE NUT, 5/16-18 UNC STAINLESS STEEL

5 SS HEX SERRATED FLANGE BOLT, 5/16-18 UNC, BLACK COATED STAINLESS STEEL W/ POWDER COATED HEAD

REVISION

DESCRIPTION

PRODUCT

DO NOTSCALE 9 OF 11A3800042

CLICK FIT SYSTEM CUT SHEETMIDCLAMP

SHEETSHEET SIZE

A. MORANO T. RAY 1/24/2020DRAWN BY APPROVED BY DATE

01DRAWING NUMBER

C COPYRIGHT ECOFASTEN SOLAR, ALL RIGHTS RESERVED. THE INFORMATION DISCLOSED HEREIN IS DEEMED TO BE CONFIDENTIAL, PROPRIETARY, AND A TRADE SECRET OF ECOFASTEN SOLAR. THIS INFORMATION MAY NOT BE USED, REPRODUCED, OR DISCLOSED WITHOUT THE EXPRESSED WRITTEN CONSENT OF ECOFASTEN SOLAR.

THIRD ANGLE PROJECTION

A A

B B

C C

D D

E E

F F

8

8

7

7

6

6

5

5

4

4

3

3

2

2

1

1

DIMENSIONS ARE IN INCHES

SEE CONFIG TABLE

1

4

2

3

1.6 1/2 IN HEX

PANNELHEIGHT

1.5 1.1

0.2

0.6

1.5

DATE OF MANUFACTURE

SIDE VIEW

ISO VIEW

FRONT VIEW

TOP VIEW

FRONT VIEW (EXPLODED)

CONFIGURATION TABLE

SKU COMPATIBLE PANNEL HEIGHT

1510016 30MM

1510017 32MM

1510018 35MM

1510019 38MM

1510020 40MM

1510021 45MM

ITEM DESCRIPTION MATERIAL

1 ENDCLAMP CLICKER ALUMINUM, ANNODIZED BLACK

2 SS HEX SERRATED FLANGE BOLT, 5/16-18 UNC, BLACK COATED STAINLESS STEEL W/ POWDER COATED HEAD

3 SS SQUARE NUT, 5/16-18 UNC STAINLESS STEEL

4 ENDCLAMP TOP PLATE ALUMINUM, ANNODIZED BLACK

REVISION

DESCRIPTION

PRODUCT

DO NOTSCALE 10 OF 11A3800042

CLICK FIT SYSTEM CUT SHEETEND CLAMP

SHEETSHEET SIZE

A. MORANO T. RAY 1/24/2020DRAWN BY APPROVED BY DATE

01DRAWING NUMBER

C COPYRIGHT ECOFASTEN SOLAR, ALL RIGHTS RESERVED. THE INFORMATION DISCLOSED HEREIN IS DEEMED TO BE CONFIDENTIAL, PROPRIETARY, AND A TRADE SECRET OF ECOFASTEN SOLAR. THIS INFORMATION MAY NOT BE USED, REPRODUCED, OR DISCLOSED WITHOUT THE EXPRESSED WRITTEN CONSENT OF ECOFASTEN SOLAR.

THIRD ANGLE PROJECTION

A A

B B

C C

D D

E E

F F

8

8

7

7

6

6

5

5

4

4

3

3

2

2

1

1

DIMENSIONS ARE IN INCHES

SEE CONFIG TABLE

3.4

SYSTEM IDENTIFICATION STICKER

2.7

2.0

SIDE VIEW

ISO VIEW

FRONT VIEW

TOP VIEW

ITEM DESCRIPTION MATERIAL

1 CLICKFIT RAIL ENDCAP BLACK PLASTIC

REVISION

DESCRIPTION

PRODUCT

DO NOTSCALE 11 OF 11A3800042

CLICK FIT SYSTEM CUT SHEETRAIL END CAP

SHEETSHEET SIZE

A. MORANO T. RAY 1/24/2020DRAWN BY APPROVED BY DATE

01DRAWING NUMBER

C COPYRIGHT ECOFASTEN SOLAR, ALL RIGHTS RESERVED. THE INFORMATION DISCLOSED HEREIN IS DEEMED TO BE CONFIDENTIAL, PROPRIETARY, AND A TRADE SECRET OF ECOFASTEN SOLAR. THIS INFORMATION MAY NOT BE USED, REPRODUCED, OR DISCLOSED WITHOUT THE EXPRESSED WRITTEN CONSENT OF ECOFASTEN SOLAR.

THIRD ANGLE PROJECTION

A A

B B

C C

D D

E E

F F

8

8

7

7

6

6

5

5

4

4

3

3

2

2

1

1

DIMENSIONS ARE IN INCHES

1510041