planet partitioning – planet partitioning · web view25mm venetian blinds, tilt only via battery...
TRANSCRIPT
V1.02
XxxxxxXxxxxxXxxxxxXxxxxxXxxxxx
130A RELOCATABLE PARTITION SYSTEM(Insert usage/location)
Product Manufacturer:- Planet Partitioning
Contact details: (insert details from below) Product Reference:
- p20 FireClear Partition System Strength Grade: (delete as appropriate)
- BS 5234-2:1992 partitions Annex A (determination of partition stiffness)Maximum deflection allowedMedium Duty 20mmHeavy Duty 15mmSevere Duty 10mmAnnex G (Determination of resistance to crowd pressure)Horizontal uniformly distributed line load0.74kN/m1.5kN/m3.0kN/m
- BS 6180:2011 Barriers in and about buildingsHorizontal uniformly distributed line load (L/65 or 25mm whichever is smaller)0.74kN/m1.5kN/m3.0kN/m
Fire Resistance of complete system to BS 476-22:- E30 Integrity Only (30/30 Through Glass)
Sound Insulation to EN ISO 10140-2 and ISO 717-1: - 38dB (Rw)
Partition Height: - insert height mm (max height 2900mm)
Partition Abutments: - Head Detail:
50mm deep x 27mm wide Aluminium Channel (no deflection)- Floor Detail:
27mm deep x 27mm wide Aluminium Channel- Wall Abutments:
27mm deep x 27mm wide Aluminium Channel Framing:
- Extruded Aluminium sections Glazing Junctions/Corners:
- Intumescent silicone capped butt joint Skirting/Sills:
- Refer to floor detail options detailed above Trims:
- Not applicable – Refer to framing/head/floor/wall abutment clauses Solid Panels:
- Not applicable Glazing Type: (delete as appropriate)
- Single, centre glazed multi layer laminated FireGlass Manifestation: (delete as appropriate)
- To architects choice and in accordance with the requirements of Approved Document K: (delete as appropriate)
- Allowance of 2nr rows 50mm dots or square (minimum) Opal Frost- Artwork and custom manifestation to client design
Blinds: - Not Applicable
Door Sets Type:- Various doorsets are compatable with the FireClear range of glazed screens, please consult with
your local Planet office for further information & options
Accessories: - Refer to Planet Partitioning for further information
Special Requirement’s: (Delete as appropriate)- Sustainability – System to conform to the requirements of
BREEAMSKALEED
- BIM – System to come complete with Revit models- Special Requirement’s (Insert Requirement’s)
Finishes/Colour: (delete as appropriate)- Polyester Powder Coated RAL (Insert Reference)- Polished & Chemically brightened (Insert Reference)- Linish & Chemically brightened (Insert Reference)- Etch & Anodise (Insert Reference)
130B RELOCATABLE PARTITION SYSTEM(Insert usage/location)
Product Manufacturer:- Planet Partitioning
Contact details: (insert details from below) Product Reference:
- P54 FireClear Partition System Strength Grade: (delete as appropriate)
- BS 5234-2:1992 partitions Annex A (determination of partition stiffness)Maximum deflection allowedMedium Duty 20mmHeavy Duty 15mmSevere Duty 10mmAnnex G (Determination of resistance to crowd pressure)Horizontal uniformly distributed line load0.74kN/m1.5kN/m3.0kN/m
- BS 6180:2011 Barriers in and about buildingsHorizontal uniformly distributed line load (L/65 or 25mm whichever is smaller)0.74kN/m1.5kN/m3.0kN/m
Fire Resistance of complete system to BS 476-22:- E30 Integrity Only (30/30 Through Glass)
Sound Insulation to EN ISO 10140-2 and ISO 717-1: (delete as appropriate)- 38dB (Rw) single glazed- 43db (Rw) double glazed- 44dB (Rw) double glazed
Partition Height: - insert height mm (max height 2900mm)
Partition Abutments: - Head Detail:
50mm deep x 54mm wide Aluminium Channel (no deflection)deep x 100mm wide Aluminium Channel (no deflection)
- Floor Detail:27mm deep x 54mm wide Aluminium Channel
- Wall Abutments:p54 - 27mm deep x 54mm wide Aluminium Channel
Framing:- Extruded Aluminium sections
Glazing Junctions/Corners: (delete as appropriate)- Intumescent silicone capped butt joint to fire glass- Vertex/Linea/Nova dryjoint to non fire glass
Skirting/Sills:
- Refer to floor detail options detailed above Trims:
- Not applicable – Refer to framing/head/floor/wall abutment clauses Solid Panels:
- Not applicable Glazing Type: (delete as appropriate)
- Single, offset glazed multi layer laminated FireGlass- Double, offset glazed multi layer laminated FireGlass plus non fire
Laminated glassToughened glassHeat Soaked Toughened glass
Manifestation: (delete as appropriate)- To architects choice and in accordance with the requirements of Approved
Document K: (delete as appropriate)- Allowance of 2nr rows 50mm dots or square (minimum) Opal Frost- Artwork and custom manifestation to client design
Blinds: - Not Applicable
Door Sets Type:- Various doorsets are compatable with the FireClear range of glazed screens, please consult with
your local Planet office for further information & options Accessories:
- Refer to Planet Partitioning for further information Special Requirement’s: (Delete as appropriate)
- Sustainability – System to conform to the requirements of BREEAMSKALEED
- BIM – System to come complete with Revit models- Special Requirement’s (Insert Requirement’s)
Finishes/Colour: (delete as appropriate)- Polyester Powder Coated RAL (Insert Reference)- Polished & Chemically brightened (Insert Reference)- Linish & Chemically brightened (Insert Reference)- Etch & Anodise (Insert Reference)
130C RELOCATABLE PARTITION SYSTEM(Insert usage/location)
Product Manufacturer:- Planet Partitioning
Contact details: (insert details from below) Product Reference:
- p100 FireClear Partition System Strength Grade: (delete as appropriate)
- BS 5234-2:1992 partitions Annex A (determination of partition stiffness)Maximum deflection allowedMedium Duty 20mmHeavy Duty 15mmSevere Duty 10mmAnnex G (Determination of resistance to crowd pressure)Horizontal uniformly distributed line load0.74kN/m1.5kN/m3.0kN/m
- BS 6180:2011 Barriers in and about buildingsHorizontal uniformly distributed line load (L/65 or 25mm whichever is smaller)0.74kN/m1.5kN/m3.0kN/m
Fire Resistance of complete system to BS 476-22:- E30 Integrity Only (30/30 Through Glass)
Sound Insulation to EN ISO 10140-2 and ISO 717-1: (delete as appropriate)- 38dB (Rw) single glazed- 50dB (Rw) double glazed- 54db (Rw) double glazed
Partition Height: - insert height mm (max height 2900mm)- Partition Abutments: - Head Detail:
50mm deep x 100mm wide Aluminium Channel (no deflection) - Floor Detail:
27mm deep x 100mm wide Aluminium Channel - Wall Abutments:
p100 - 27mm deep x 100mm wide Aluminium Channel Framing:
- Extruded Aluminium sections Glazing Junctions/Corners:
- Intumescent silicone capped dry joint Skirting/Sills:
- Refer to floor detail options detailed above Trims:
- Not applicable – Refer to framing/head/floor/wall abutment clauses Solid Panels:
- Not applicable Glazing Type: (delete as appropriate)
- Single, offset glazed multi layer laminated FireGlass- Double, offset glazed multi layer laminated FireGlass plus non fire
Laminated glassToughened glassHeat Soaked Toughened glass
Manifestation: (delete as appropriate)- To architects choice and in accordance with the requirements of Approved
Document K: (delete as appropriate)- Allowance of 2nr rows 50mm dots or square (minimum) Opal Frost- Artwork and custom manifestation to client design
Blinds: (delete as appropriate)- Not Required- 15mm Venetian blinds, tilt only via battery operated remote control - 25mm Venetian blinds, tilt only via battery operated remote control
Door Sets Type:- Various doorsets are compatable with the FireClear range of glazed screens, please consult with
your local Planet office for further information & options Accessories:
- Refer to Planet Partitioning for further information Special Requirement’s: (Delete as appropriate)
- Sustainability – System to conform to the requirements of BREEAMSKALEED
- BIM – System to come complete with Revit models- Special Requirement’s (Insert Requirement’s)
Finishes/Colour: (delete as appropriate)- Polyester Powder Coated RAL (Insert Reference)- Polished & Chemically brightened (Insert Reference)- Linish & Chemically brightened (Insert Reference)- Etch & Anodise (Insert Reference)
NOTE:All Planet products are exclusively supplied and installed by fully trained Planet Partitioning operatives only. Please see below for the regional office supporting the project.
Planet Regional Installation Offices: (delete as applicable)
South/London DivisionPlanet HouseEdward WayBurgess WayWest SussexRH15 9TZTel : 01444 [email protected]
West DivisionUnit 6Lansdowne CourtBumpers WayChippenhamWiltshireSN14 6RZTel : 01249 [email protected]
Midlands DivisionUnit 3Mercian ParkFelspar RoadTamworthB77 4DPTel : 01827 [email protected]
North West Division10 Woodway CourtThursby RoadWirral International Business ParkBromboroughWirralCH62 3PRTel : 0151 [email protected]
North DivisionUnit 3Apex Business ParkApex WayLeedsLS11 5LNTel : 0113 [email protected]
Scotland DivisionThe Wright Business Centre1 Lonmay RoadGlasglowG33 4ELTel: 0141 773 [email protected]