    1/12

    HIGHE

    FFICIENCY

    HEATR

    ECOVER

    Y

    ECMFAN

    S

    ECMCASSE

    TTES

    More

    than40

    NEW

    PRODUCTS

    www.f

    rance-

    air.com

    /innova

    tions2

    012

  • 8/14/2019 Plaquette Innov 2012 GB.pdf

    2/12

    Zaio

    Heating fan coil unit with gas burner.High performance energy solution forlow consumption buildings.

    Heating system combining a ductedlow consumption fan coil unit with a

    controller allowing temperature control

    room by room and a gas absorption

    heat pump.Collective housing dedicated solution.Medium water temperature for high

    performance system.

    EC motor guarantees a lowconsumption unit.

    Lyxos

    Solar energy recovery for SanitaryHot Water (SHW).

    SHW production system with solarcaptor and high temperature heat

    pump.

    Lyxos takes the best of each climatesituation (solar radiation, heat, rain, fog,

    wind, night and day).Thanks to the optimization of the solar

    captor performance by the heat pump,

    the system can produce SHW all year

    long.

    Soraya

    Heat recovery on housing ventilationsystem in order to pre-heat SanitaryHot Water (SHW).

    SHW pre-heating system combiningan air/water heat pump with a CMV

    exhaust fan.

    100% heat recovery on air extraction to

    pre-heat SHW.Up to 60% savings on SHW production.Collective housing dedicated solution

    with a targeted consumption lower

    than 25kWh primary energy/m2/year on

    SHW production.

    The Airfficient concept qualifies the products on which the energy efficiency is significantly improved, and the noise

    level, architectural integration and user-operation are optimized. The airfficient concept emphasizes both energyefficiency and comfort on a product performance. This concept is based on measurable and objective criterias. The

    Airfficient logo applies on ventilation products but also on heat recovery, fire protection and kitchen applications.

    The Airfficient products show one or several innovations developed by the France Air R&D teams.

    Housing |

    02

    Comfort & energy ef f i c iency

    HightEfficiencyProduct

    HightEfficiencyProduct

    HightEfficiencyProduct

    France Air 2012 creation - All rights reserved.

  • 8/14/2019 Plaquette Innov 2012 GB.pdf

    3/12

    Loona

    Static heat recovery unit with counter flow

    heat exchanger, efficiency up to 90%.

    Loona can be integrated in a globaldouble flow ventilation system in

    collective housing and allows to do

    heat recovery flat by flat according to

    the needs.

    Counter flow exchanger, efficiency upto 90%.

    By-pass integrated for free-cooling.Integrated controller.

    NaosRT ControlLow consumption exhaust fan (CMV)with constant pressure (VAV).

    Up to 50% savings on your energy bill.New high efficiency motor

    IE2.

    Air flow from 500 to 10 000 m3/h.Easy building integration with multiple

    configuration available: air dischargehorizontal or vertical.

    Variable Air Volume application.Adapted to new construction and

    revamping.

    RT control controller remote for VAVoptimization.

    Easy access for maintenance.Lower footprint.

    Obsydia

    Wall condensation gas boiler: Vergnetechnology, made in France.

    Wall gas boiler for heating and sanitaryhot water (SHW).

    Capacity 28 kW.3 models: SHW production with micro-

    accumulation, 20L integrated tank, 100L

    remote tank.Multifunction LED controller allowing

    temperature and water pressure display.

    Simplified maintenance with an accessto the main items gathered on a single

    plate.

    Better classification: lower NOxemission.

    | Housing

    BoraSupply/Return valve.

    CTD

    Design roof exhaust.

    03

    IE2motor

    Comfort & energy effic iency

    HightEfficiencyProduct

    France Air 2012 creation - All rights reserved.

  • 8/14/2019 Plaquette Innov 2012 GB.pdf

    4/12

    Massaya

    Radiating ceiling: heating and cooling.

    4 dimensions available: 1200 x 600 /1800 x 600 / 2400 x 600 / 3000 x 600.

    3 types of ceilings: PQ4 - 080 : Average of 82 W/m -maximum pressure : 10 bars,

    PQ4 - 120 : Average of 88 W/m -

    maximum pressure : 10 bars, PQ6 - 080 : Average of 94 W/m -maximum pressure : 16 bars.

    Especially designed for close or openspace offices, shops, airports, hospitals

    or other institutional buildings.

    Energy savings. Solution for lowconsumption buildings.

    Easy maintenance.Easy integration in false ceilings.Higher comfort due to the radiated

    mode used.

    Opti Drive

    Variable air volume box, small airflows.

    Air flow from 30 m3/h onwards.Diameter from 100 to 630mm.Class 4 sealness according to EN 1751.Double skin 50mm insulation with

    rockwool available on option.

    Parameters can be set at the factoryor on site.

    Low noise level.Low pressure drop.

    BTDRDcoSmoke exhaust damper without grillecompliant to the European norm EN1366-10.

    Smoke damper 1 or 2 leaves.New concept compliant to the

    European norm EN 1366-10.

    The BTDR Deco is conceived without

    grille for a perfect architecturalintegration in the building.

    Possibility to paint or cover the BTDRDeco without any constraints.

    The BTDR Deco is perfectly sealedin order to avoid air leaks on the

    ventilation network.

    Tertiary |

    04

    HightEfficiencyProduct

    France Air 2012 creation - All rights reserved.

  • 8/14/2019 Plaquette Innov 2012 GB.pdf

    5/12

    Twintop

    Supply/Return grille in ABS (plastic).

    Grille + plenum allowingsimultaneously:

    Air supply with Coanda eect, Fresh air supply. Return air.

    Easy and quick fitting of the plenum.

    Low noise level.Low pressure drop.Light and robust.Esthetical and discrete.3 sizes from 50 to 700 m3/h.Adapted to the housing, hotel and

    tertiary applications.

    Wall or ceiling mounted.

    Actinys

    Kitchen hood with heat recovery andair make-up integrated.

    Heat recovery on kitchen exhaust inorder to pre-heat fresh air:When fresh air is close to 0C, air supply

    in the kitchen is close to 18C.

    Efficient control:Parameters control(summer/winter/automatic mode,washes frequency settings, LED

    settings). User-friendly controller with

    a touch mode.

    Energy savings:efficient heat recoveryexchanger, energy savings display, light

    by LED technology.

    Airgicook

    Design software (air flow calculation)for professional kitchen.

    Calculation of operational air flowsaccording to the norm VDI 2052.

    User-friendly software.Quick selection of the adapted

    equipment: hoods, fans and heat

    recovery.Detailed technical sheets edition.

    | Tertiary /Kitchen

    Deox EvoMotorized kitchen hood with lights and variator integrated.

    Alto Compensation

    Kitchen hood high comfort with integrated compensation (make-up).

    05

    C om f ort & energ y ef f i c i enc y

    EUROPEAN PATENTIN PROGRESS

    France Air 2012 creation - All rights reserved.

  • 8/14/2019 Plaquette Innov 2012 GB.pdf

    6/12

    Plate Box95High efficiency heat recoveryunit with counter flow exchanger.Installation in false ceiling.

    Double skin insulation 30mm

    Air ow from 100 to 2500 m3/h.

    Counter flow exchanger, efficiency

    up to 95%. Eurovent certified.

    ECM motor low consumption.High efficiency plug fan.F5 filter on supply side and G4 on return

    side.

    Electrical/Hot water coil or change-overintegrated.

    Easy maintenance with access from thebottom.

    Power Box95 BCHigh efficiency heat recoveryunit with counter flow exchanger.Outdoor/Indoor installation.

    Double skin insulation 25mm

    Air ow from 100 to 4500 m3/h.

    Counter flow exchanger, efficiencyup to 95%. Eurovent certified.

    ECM motor low consumption.High efficiency plug fan.F5 filter on supply side and G4 on return

    side.

    Electrical/Hot water coil or change-overintegrated.

    Multiple air configuration.

    No Play95High efficiency heat recoveryunit with counter flow exchanger.Outdoor/Indoor installation.

    Double skin insulation 50mm

    Air ow from 500 to 6000 m3/h.

    Counter flow exchanger, efficiency

    up to 95%. Eurovent certified.

    ECM motor low consumption.High efficiency plug fan.F5 filter on supply side and G4 on return

    side.

    Electrical/Hot water coil integrated.

    Heat recovery |

    06

    Touch screen remote controller

    Control dedicated to the building ventilation Air flow control :

    - Constant air volume (CAV)- Variable Air Volume (VAV) connected to a CO2sensor / Presence sensor or 0-10V signal

    - Constant pressure- Over-ventilation management (night mode) Supply or Return temperature set point

    Heat recovery optimization

    - Free cooling- Summer/Winter heat recovery BMS communication compliant

    C om f ort & energ y ef f i c i enc y

    HightEfficiencyProduct

    HightEfficiencyProduct

    HightEfficiencyProduct

    France Air 2012 creation - All rights reserved.

  • 8/14/2019 Plaquette Innov 2012 GB.pdf

    7/12

    Power Play90 BCHigh efficiency heat recovery unitwith thermal wheel exchanger.

    Air ow from 100 to 7000 m3/h.

    Wheel exchanger, efficiency up to 85%.

    ECM motor low consumption.F5 filter on supply and return side.Electrical/Hot water coil integrated.Integrated controller.BMS communication: Modbus RTU.

    Power Play MaxAir Handling Unit with highefficiency exchanger.

    Air ow up to 26000 m3/h.

    Compact AHU.

    Double skin 45mm.Double stage filtration.ECM low consumption motor (option).Heating/Cooling coil.Software selection for customized

    selection.

    Adapted for comfort ventilationin tertiary or industrial buildings.

    Power School

    Heat recovery unit for classrooms.

    Air ow from 200 to 900 m3/h.

    Compact heat recovery vertical cabinet.Counter flow exchanger, efficiency

    up to 90%.

    ECM motor low consumption.

    F7 filter on supply side and F5 on returnside.Variable Air Volume with CO2 sensor.Installation directly in the room to be

    treated.

    Easy maintenance.Low noise level.

    |Heat recovery / AHU

    Vista 400Extra slim AHU for ceiling installation.

    07

    HightEfficiencyProduct

    HightEfficiencyProduct

    HightEfficiencyProduct

    France Air 2012 creation - All rights reserved.

  • 8/14/2019 Plaquette Innov 2012 GB.pdf

    8/12

    NoumaECM4 ways cassette with ECM motor.

    Savings on your electricity bill

    up to 65%.

    Capacity from 1.4 to 8.5 kW.3 sizes available.

    2 pipes or 4 pipes version.Integrated controller on 3 way valve

    and air ventilation.

    Infra-red or wired remote controller.Adapted to air conditioning

    of shopping malls, lobbies, etc

    AdeliaECM1 or 3 ways cassette with ECM motor.

    Savings on your electricity bill

    up to 75%.

    Capacity from 0.51 to 5.1 kW.4 sizes available.

    2 pipes or 4 pipes version.2 types of diusion:

    1 way diusion: Adelia One,3 ways diusion design: Adelia XO.

    Integrated controller on 3 way valveand air ventilation.

    Infra-red or wired remote controller.Adapted to air conditioning of offices,

    hotel rooms, lobbies, etc

    ElviraDco ECM4 ways cassette with ECM motor.Architectural integration.

    Savings on your electricity bill

    up to 75%.

    Capacity from 1.2 to 11 kW.3 sizes available.2 pipes or 4 pipes version.Low noise level.Perfect Coanda eect.Infra-red or wired remote controller.Adapted to air conditioning of offices,

    conference and hotel rooms, etc

    Chilled water FCU |

    VRFVariable Refrigerant flow DX systems:GENERAL Distributor.

    Available 2ndquarter 2012

    08

    Available 2ndquarter 2012

    C om f ort & energ y ef f i c i enc y

    France Air 2012 creation - All rights reserved.

  • 8/14/2019 Plaquette Innov 2012 GB.pdf

    9/12

    Vista400Extra slim AHU.

    False ceiling installation Height 400mm. Access from the bottom or the side.

    3 sizes: Air flow up to 4 500 m3/h.4 configurations available: Filter +

    Fan section with:

    electrical coil, hot water coil, cold water coil, change-over coil.

    High performance plug fan.Low footprint.

    Prozone3Direct expansion / DRV

    Prozone3Chilled water

    Temperature controller for each room.

    Ideal for heating or cooling applicationin centralized air conditioning system.

    Ducted FCU application in housing oroffices (tertiary buildings).

    Centralized installation.Individual control from 6 to 16 areas.Optimal diusion and architectural

    integration.

    Available in version 2 pipes / 2 pipes +wire /4 pipes.

    Wireless communication system.Easy installation.Touch and design controller.Energy savings:

    BMS compatible (Modbus). Option BOXDX (for DX/DRVapplication) for an optimal control

    of both the outdoor and indoor units.

    By-pass rarely used thanks to theoptimal control.

    Hgoa ECMFan Coil Unit with ECM lowconsumption motor.

    Savings on your electricity bill

    up to 75%.

    Versions with or without cabinet

    (casing).5 sizes: air flow from 120 to 1400 m3/h.

    3 versions: 2 pipes / 2 pipes + wire /

    4 pipes.

    Additional coil 1 or 2 rows.

    Mounted controllers with water and air

    control.

    Adapted to shops, offices, hotels

    | Direct expansion units

    09

    HightEfficiencyProduct

    France Air 2012 creation - All rights reserved.

  • 8/14/2019 Plaquette Innov 2012 GB.pdf

    10/12

    RectilysECMFan with low consumption ECM motorand filter section.

    High efficiency ECM motor.VAV control available with Evolys

    controller.

    Optimal electrical consumption with airflow from 100 to 4000 m3/h.

    Fine tuning control thanks to a 0-100%fader integrated in the fan.

    Remote control thanks to the Evolyscontroller (option).

    Lower footprint of the fan (-20% vsstandard Rectilys).

    Compact fan with filter drawerG4, F5 or F7.

    Optimization of the dynamic pressureloss.

    SimounECMRoof fan low consumptionup to 14 000 m3/h.

    High efficiency ECM motor: up to 40%energy savings.

    New top design: compact andesthetical.

    Air flow setting (0-100%) thanks to

    the integrated fader or via the remotecontroller Evolys (option).

    VAV or CAV control available with Evolyscontroller (option).

    7 sizes from 250 to 630.Adapted to air exhaust or transfer

    in tertiary or industrial premises

    (not adapted to smoke extraction).

    Evolys

    Controller for ECM motors.

    Design controller for ECM motor wallmounted or fitted on the unit.

    Accurate air flow setting 0-100% with a0-10V signal or PWM.

    IP 54 protection for the wall mountedversion and IP44 for the tted version.

    Remote control up to 40m in PWMversion.

    Low consumption ventilation |

    Evolys VLCD controller for ECM motors. Variousintegrated functions such as: clock, cloggedfilter, instantaneous air flow meter

    Hint!The Evolys controller canalso control tensionor frequency variators witha 0-10V input signal

    10

    TKC V ECMCompact low consumption roof fan verticaldischarge and ECM motor. Available also inhorizontal discharge.

    Kana ECMExtra slimlow consumption fan with ECM motorfor false ceiling or tiny places installation.

    C om f ort & energ y ef f i c i enc y

    Comfort & energy efficiency

    HightEfficiencyProduct

    HightEfficiencyProduct

    France Air 2012 creation - All rights reserved.

  • 8/14/2019 Plaquette Innov 2012 GB.pdf

    11/12

    SilensairECMDouble skin and ECM motor fan.

    High efficiency ECM motor.50mm insulation.Air flow from 100 to 5400 m3/h.6 sizes with circular connections

    from 125 to 500mm.

    VAV control available for optimal

    electrical consumption.Air flow setting (0-100%) thanks to

    the integrated fader or via the remote

    controller Evolys (option).

    Easy maintenance, access panel easyto take o.

    HeliciaECMAxial roof fan low consumptionup to 6 000 m3/h.

    ECM motor: up to 30% energy savings.Lower noise level thanks to

    aerodynamic 3D blades.

    Air flow setting (0-100%) thanks tothe integrated fader or via the remote

    controller Evolys (option).VAV or CAV control thanks to Evolys V

    (option).

    Diameters available from 315 to 500mm.Air flow from 0 to 6000 m3/h.Adapted to air extraction in industrial

    premises or warehouses.

    Ventilation only.

    HelipacECMAxial fan low consumptionup to 6 000 m3/h.

    ECM motor: up to 30% energy savings.Lower noise level.Air flow setting (0-100%) thanks to

    the integrated fader or via the remote

    controller Evolys (option).

    VAV or CAV control thanks to Evolys V(option).

    Available in ducted or wall mountedversions.

    Air flow from 0 to 6000 m3/h.Diameters available from 315

    to 500mm.

    | Low consumption ventilation

    Ibiza RVPolypropylene exhaust roof fan, verticaldischarge for corrosive atmospheres.

    11

    Airgif@nSelection Software for consumption inhousing, tertiary and kitchen applications.

    C om f ort & energ y ef f i c i enc y

    HightEfficiencyProduct

    HightEfficiencyProduct

    HightEfficiencyProduct

    France Air 2012 creation - All rights reserved.

  • 8/14/2019 Plaquette Innov 2012 GB.pdf

    12/12

    Cassiope

    Filtering ceiling for operation theatreswith high recycling air flow.

    Unidirectional flow ceiling for Risk 3or 4 operation theatres.

    Recycling unit allowing to recycleup to 90% of the total air flow supplied.

    3 return air modes available: high, low

    or mix (high and low).8 sizes available.Coils on option.Air flow from 2300 to 13000 m3/h.Adapted to hospital hygiene

    application.

    Energy savings.Operation theatres multiple use.

    Installation cost reduced thanks to a lowfresh air volume needed.

    Technical rooms size reduced.

    Opus

    Packaged unit.

    Gas heating burner with evaporativecooling in a single packaged unit.

    Green system: no refrigerant used.Integrated Controller.

    Economical solution compare to directexpansion roof tops.

    2 sizes: Opus 35: 35 kW heating capacity. Opus 50 : 50 kW heating capacity. From 16 to 38 kW cooling capacityaccording to the outdoor conditions

    (temperature and humidity).

    Variable air flow : Heating: from 3 000 to 10 000 m3/h, Cooling: from 1 000 to 10 000 m3/hwith 1000 m3/h step.

    Adapted to industrial premises or bigvolume warehouses.

    Titanium C2autonomeDust extractor with horizontalcartridges and pneumatic uncloggingsystem with integrated low noise fan.

    Adapted to mechanical industry (drydust, welding fumes, light oil clouds)

    and simple dust extraction.

    Low footprint.Integrated fan.Big filtration dimension.Easy maintenance thanks to the

    horizontal cartridges.

    All in one system: Ventilation + filtration+ integrated unclogging system.

    4 sizes available.Air flow from 2200 to 6500 m3/h.Filtration area: from 37 to 108 m2.Static pressure available: from

    1000 to 1200 Pa.

    Accessories available on option.

    Air quality / Heating |

    Box AirGas Heating burner (ducted or direct).Application: big volumes heating (for medium or wellinsulated buildings). Packaged unit including fan,

    gas burner and control box.

    Evolix VoltaA new range of electrical radiating panels for tertiaryor industrial application. A discrete architectural integrationfor an efficient heating solution.

    12

    www.traitdunion-co

    m.fr-DCO1201/01

    HightEfficiencyProduct