plastic, cosmetic surgery

8
Plastic & Cosmetic Surgery with Swiss Quality Equipment 67234 EN • NOUVAG AG © , all rights reserved • Subject to change

Upload: agnes-kovacs

Post on 09-Mar-2016

244 views

Category:

Documents


9 download

DESCRIPTION

plastic, cosmetic surgery

TRANSCRIPT

Page 1: plastic, cosmetic surgery

Plastic & Cosmetic Surgerywith Swiss Quality Equipment

6723

4 EN

• N

OU

VAG

AG

©, a

ll ri

ghts

rese

rved

• Su

bjec

t to

chan

ge

Page 2: plastic, cosmetic surgery

Vacuson 60 LP, state of the art Liposuction System

Reliability and simple handling are the core characteristics of this high quality Liposuction System. Famous through-out the world for it’s outstanding performance it’s used by top masters in the field of liposuction. Available also as standing model on wheels with brakes.

The range topping Vacuson 60 LP is a vibration liposuction system with built–in infiltration pump. Supplied complete with the ergonomic Conform Cannula handpiece. The result is a pre-cisely adjusted device combina-tion for liposuction to facilitate the movement of the cannula within tissue, with or without tumescent local anaesthetic.

This combination supports mod-elling and guaranteed optimum cosmetic results. The handpiece is compatible with all common cannulaes. The Vacuson 60LP can be con-trolled with a foot pedal, allow-ing the surgeon to concentrate on the task at hand.

Type: Vacuson 60 LP

Input Voltage: 115/230 Volt at 50-60 Hz

Suction performance: up to 60 l/h

Max. vacuum: -0.9 bar /686 mm HG

Flow rate infiltration pump: 2 to 22 l/h

Max. pressure: 2.5 bar

Conform cannula stroke: 2.5 mm

Conform cannula frequency: 3600 strokes/min.

Conform cannula motor: electronic motor, autoclavable

Advantages for the surgeon:

• Point accurate work / optimum fat suction• Power-saving and gentle treatment

• Shorter operating times• Optimized time / cost calculation• Best possible gentle patient treatment• Handpiece is compatible with all common cannulaes

Advantages for the patient: • Optimum cosmetic results• Gentle treatment

• No thermal stress on the tissue• Fast recovery after the operation

within tissue, with or without tumescent local anaesthetic.

Art. No.: 4179

Page 3: plastic, cosmetic surgery

TCM 3000 BL, the workhors for versatile tasksDeveloped especially for surgery appliances, this microprocessor controlled unit is very user friendly and that considerably facilitates the daily practice routine of the surgeon .

Our Trauma care Instruments consist of a micro processor controlled micro motor – TCM 3000 BL that can be universally used for hand, foot and all other small bone surgeries. Due to its versatility the surgeon can use any type of saws like reciprocating, oscillating, sagittal as well as straight and angled handpieces and also the K-wire handpiece.

Art. No.: 3286

The constant torque settings are maintained by an automatic torque control circuit.

Type: TCM 3000 BL

Input Voltage (switchable): 100/115/230 Volt at 50-60 Hz

Speed range, micromotor: 500 – 40’000 rpm

Drive system: Electronic motor (brushless)

Motor torque: 10 Ncm

Dimensions, control unit: 115 x 120 x 180 mm, (W x H x D)

Weight, control unit: 1.8 kg

Conform cannula frequency: 3600 strokes/min.

Conform cannula motor: electronic motor, autoclavable

Approval: CE1275 Class IIa, CSA, FDA, IEC 601, protection class IIa, applied part type BF

• Best price/performance ratio

• High performance and torque

• Torque depends on the rota-tion speed and is reached even at low rotation speeds

• Highest quality and reliabil-ity

• Wide range of features and accessories

Page 4: plastic, cosmetic surgery

Type: TCM 3000

Input Voltage (switchable): 115/230 Volt at 50-60 Hz

Speed range, micromotor: 2’000 – 30’000 rpm

Drive system: DC-Motor (brush motor)

Motor torque: 5 Ncm

Dimensions, control unit: 85 x 100 x 170 mm, (W x H x D)

Weight, control unit: 1.9 kg

Approval: CE1275 Class IIa, CSA, FDA, IEC 601, protection class IIa, applied part type BF

• Best price-/performance ratio

• Small and reliable• Multifunctional• Easy handling and mainte-

nance• LED-Display

TCM 3000, convenient and powerfulIt’s a microprocessor controlled motor system used in plastic surgery, as well as for dental implantology, for drilling, milling and grinding.

Due to the size and versatility it is a very convenient solution in every practice. Instead of an ON/Off footswitch, it can be used with a vario pedal, that lets you regulate the speed by foot. The micro motor comes with a standard E-type coupling that accepts any E-type contra angle and handpiece. The torque Mode in this device persists of an automatic torque limiter and an automatic stop when the preselected torque is reached.

Art. No.: 1451

Page 5: plastic, cosmetic surgery

Kirschner Contra angle with INTRA EN3964 coupling, 90 mm length, 16:1 transmission, 2500 rpm, for surgical wires of 0.8 – 1.5 mm in diameter.

Surgical Wires

Length Ø mm Art. No.

70 mm 0.8 5013

70 mm 1.0 5014

150 mm 0.6 5023

150 mm 0.8 5015

150 mm 1.0 5016

150 mm 1.2 5017

150 mm 1.5 5018

Surgical Wires are available in a box of 10.

Kirschner hand piece, unique on the marketThe ultra light Kirschner Handpiece was developed for setting Kirschner wires to support the osteosynthesis and for the correction of degenerative alteration of the skeleton.

The Kirschner Wires used for temporary and permanent fixation of bones and implants are available in different lengths and diameters. They’re also available with a threaded portion in the middle. The simplicity of changing wires address the surgeons needs. With the motor system that best suites your needs the process of setting the wires with the Kirschner handpiece gets done easier with an accurate result that gives you confidence and safety.

Art. No.: 5160

Tattooing Handpiece, professional and ergonomic

Art. No.: 5020

Modern aesthetic reconstructive surgery required the development of a tattooing handpiece which meets both, the modern operators requirements and the complex hygiene regulations.The maximum penetration depth of 2 mm can be

adjusted in 0.2 mm increments using the distance sleeve. Dye uptake is induced by capillary action with a recommendet motor speed of 3’000 to 4’000 rpm, that corresponds to a stroke rate of 50 to 67 strokes per second.

Corresponding workpieces

Head 1 Needle 3 Needles

Art. No. 5021 5024 5025

Head 7 Needles 10 Needles 12 Needles

Art. No. 5022 5026 5027 5028

Page 6: plastic, cosmetic surgery

• Angled front surface for optimal visibility for the procedure

• Fine tuning of cutting depth, in increments of 0.05 mm

• 3 Dermatome sizes available• Easy blade changing• Reduction baseplates avail-

able for 75 mm Dermatome• Durable and solid design

Dermatome, precision paired with operational safetyOur Dermatomes are available in 3 different sizes. The cutting depth is adjustable from 0.05 mm up to 0.55 mm in increments of 0.05 mm. The easy handling keeps your focus on the patient.

Well designed details make these Dermatomes to leaders in skin transplantation. The front surface is slightly angled to give a clear visibility during the grafting procedure. The weight of the instrument is balanced for optimal results. To change the blade isn’t either a hassle. These features give you some extra confidence in your work and safety for your patient.

Art. No.: 1990

Art. No.: 1991

Art. No.: 1992

Art. No.: 19887Art. No.: 19886

Art. No.: 1997

Art. No.: 1996

Art. No.: 1995

Dermatome 25 mm /50 mm/75 mmThe Dermatomes with INTRA EN3964 coupling have a cutting depth of 0.05 mm – 0.55 mm. The recommended speed is 8,000 rpm.

Reduction Support BaseThe Reduction Support Base works only on the Dermatome with 75 mm width. It comes in two sizes, 50 mm and 25 mm.

Spare BladesThe spare blades are available in packing units with 10 pieces.

Page 7: plastic, cosmetic surgery

MSS 5000 Micro-jigsawwith INTRA EN3964 coupling, removable irrigation tube, recom-mended speed 15,000 rpmThe micro-jigsaw for sawing and rasping with tools of different lengths and designs.

Extensions and accessories, that perfectly fit to the Nouvag device of your choiceCheck out our Micro Motors, Contra Angles and Handpieces for your specific applications. We have a wide range of extensions and accessories that are manufactured at Nouvag in its legendary swiss quality. Contact our sales representative and share your wish.

Article No.: 5046

Rasp tool, hardened steel,Packing unit of 1 piece.

Article No.:

11 mm 5041 14 mm 5042 18 mm 5043 22 mm 5044 26 mm 5045 17 mm, rounded 510521 mm, rounded 5106

Spare blades of 0.4 mm thickness, in packing units of 6 pieces. Article No.:

OMS 5000 Oscillating micro-sawwith INTRA EN3964 coupling, removable irrigation tube, recom-mended speed 15,000 rpm.These micro-saws come into use in all applications where it is necessary to cut at right angles.

MOS 5000 Sagittal Sawwith INTRA EN3964 coupling, removable irrigation tube, recom-mended speed 15,000 rpm.The sagittal saw is ideal for applica-tions in which the two other saws are unsuitable for reasons of space.

6 mm

4 mm10 m

m

12 mm

9 mm15 m

m

16 mm

27 mm33 m

m

45 mm

6 mm

4 mm10 m

m

12 mm

9 mm15 m

m

16 mm

27 mm33 m

m

45 mm

Fine cuts with 0.4 mm of thickness! Packing unit with one piece.

Saw blade Cutting depth Shaft length Art. No.

6.3 mm 33 mm 5100

6.3 mm 45 mm 5099

13.3 mm 33 mm 5093

13.3 mm 45 mm 5096

13.3 mm 33 mm 5094

13.3 mm 45 mm 5097

13.3 mm 33 mm 5095

13.3 mm 45 mm 5098

6 m

m

4 m

m 10 m

m

12 m

m

9 m

m 15 m

m

16 m

m

27 m

m 33 m

m

45 m

m

6 m

m

4 m

m 10 m

m

12 m

m

9 m

m 15 m

m

16 m

m

27 m

m 33 m

m

45 m

m

6 m

m

4 m

m 10 m

m

12 m

m

9 m

m 15 m

m

16 m

m

27 m

m 33 m

m

45 m

m

6 mm

4 mm

10 mm

12 mm

9 mm

15 mm

16 mm

27 mm

33 mm

45 mm

6 mm

4 mm

10 mm

12 mm

9 mm

15 mm

16 mm

27 mm

33 mm

45 mm

6 m

m

4 m

m 10 m

m

12 m

m

9 m

m 15 m

m

16 m

m

27 m

m 33 m

m

45 m

m

4 mm 6 mm 6 mm 6 mm 10 mm 12 mm

10 mm

29 m

m

12 m

m

17 m

m

5 mm

Saw blades of 0.4 mm thickness, in packing units of 6 pieces.

Art.

No.

: 511

5Ar

t. N

o.: 5

116

Art.

No.

: 5114

Art.

No.

: 511

7Ar

t. N

o.: 5

118

Art.

No.

: 511

9

Art. No.: 5040

Art. No.: 5090

Art. No.: 5110

Article No.: 1960Angled handpiece for ENT, length 125 mm, 1:1 trans mission, spray nozzle and Quick lock for 70 mm/ ø 2.35 mm instruments

Article No.: 1961Angled handpiece for ENT, length 145 mm, 1:1 trans mission, spray nozzle and Quick lock for 95 mm/ ø 2.35 mm instruments

Article No.: 1962Angled handpiece for ENT, length 175 mm, 1:1 trans mission, spray nozzle and Quick lock for 125 mm/ ø 2.35 mm instruments

Article No.: 1710General surgery handpiece of 90 mm length, 1:1 trans mission, spray nozzle and Quick lock for instruments from 44 mm/ø 2.35 mm

Article No.: 1950ENT Handpiece of 105 mm length,1:1 trans mission, spray nozzle and Quick lock for 70 mm/ø 2.35 mm instruments

Article No.: 1951ENT Handpiece of 125 mm length,1:1 trans mission, spray nozzle and Quick lock for 95 mm/ø 2.35 mm instruments

Article No.: 1952ENT Handpiece of 155 mm length,1:1 trans mission, spray nozzle and Quick lock for 125 mm/ø 2.35 mm instruments

Page 8: plastic, cosmetic surgery

Overview

Vacuson 60 LP TCM 3000 BL TCM 3000

Kirschner Handpiece •

Dermatome • ( • )

Saws •

Drilling Handpiece • •

Milling, Dermabration • •

Conform Canula Handpiece • • ( • )

Tattooing Handpiece •

Suction System included •

Check the following table for which configuration suits best for your work. All contra Angles and Handpieces come with INTRA couplings and are compatible with other manufacturers. For further Information please contact the sales representative of your country.

• optimal( • ) suitable

Nouvag AG · St.Gallerstr. 23–25 · CH-9403 Goldach Phone +41 (0)71 846 66 00 · Fax +41 (0)71 846 66 [email protected] · www.nouvag.com

Nouvag GmbH · Schulthaißstr. 15 · D-78462 Konstanz Phone +49 (0)7531 1290-0 · Fax +49 (0)7531 [email protected] · www.nouvag.com

Nouvag trading partner: