Lumen Maintenance Testing of Outdoor Lighting Installations Dr Gareth John, Technical Director, Photometric & Optical Testing ILP Lighting Summit, 24 th of September 2015

Upload: institution-of-lighting-professionals

Post on 09-Apr-2017

585 views

Category:

Presentations & Public Speaking


5 download

TRANSCRIPT

Page 1: PLS 2015: Lumen maintenance testing of outdoor lighting installations

Lumen Maintenance Testing of Outdoor Lighting

Installations

Dr Gareth John, Technical Director, Photometric & Optical Testing

ILP Lighting Summit, 24th of September 2015

Page 2: PLS 2015: Lumen maintenance testing of outdoor lighting installations

Maintenance Factor• Need for maintenance-• The luminance/illuminance initially provided by a lighting installation will

decrease gradually throughout the life of the installation. • “Ratio of the average luminance/illuminance on the working plane after a certain

period of use of a lighting installation to the average luminance/illuminance obtained under the same conditions for the installation considered conventionally as new.” CIE Technical Report 154, “Maintenance of Outdoor Lighting Systems. • Degradation is down to a combination of lamp depreciation, lamp failure and

accumulated dirt.

Page 3: PLS 2015: Lumen maintenance testing of outdoor lighting installations

Maintenance FactorMF = LLMF x LSF x LMF (x SMF)*

where LLMF = the lamp lumen maintenance factor; LSF = the lamp survival factor;

LMF = the luminaire maintenance factor; and where appropriate (e.g. pedestrian subways):

SMF = the surface maintenance factor.

Page 4: PLS 2015: Lumen maintenance testing of outdoor lighting installations

Lamp Lumen Maintenance Factor

Page 5: PLS 2015: Lumen maintenance testing of outdoor lighting installations

Lamp Survival Factor

Page 6: PLS 2015: Lumen maintenance testing of outdoor lighting installations

Luminaire Maintenance Factors

Page 7: PLS 2015: Lumen maintenance testing of outdoor lighting installations

Maintenance Factor and LEDs

Page 8: PLS 2015: Lumen maintenance testing of outdoor lighting installations

Measurement of Maintenance Factor

Page 9: PLS 2015: Lumen maintenance testing of outdoor lighting installations

TR28- Measurement of Road Lighting Performance on site

• Based upon BS EN 13201-4, “Road Lighting, Methods of Measuring Lighting Performance• A practical guide to

onsite measurements with calibrated photometers

Page 10: PLS 2015: Lumen maintenance testing of outdoor lighting installations

TR28- Measurement of Road Lighting Performance on site

• A random sample of sites are checked, ideally once a month• Multipoint measurement across a grid on the roadway• Checked against software simulation

Page 11: PLS 2015: Lumen maintenance testing of outdoor lighting installations

TR28- Measurement of Road Lighting Performance on site

• Measurement conditions (from 13201-4:) • The luminaire output should be

stable• The effect of climate upon

measurement results must be considered• [Extraneous light and sources of

obstruction (parked cars, trees) must be eliminated as far as possible.

Page 12: PLS 2015: Lumen maintenance testing of outdoor lighting installations

TR28- Measurement of Road Lighting Performance on site

(Obstructions)

Page 13: PLS 2015: Lumen maintenance testing of outdoor lighting installations

TR28- Measurement of Road Lighting Performance on site

(Photometer)

Page 14: PLS 2015: Lumen maintenance testing of outdoor lighting installations

TR28- Measurement of Road Lighting Performance on site

(Uncertainties)• Ambient temperature- 25°C or 15°C?• Moonlight- up to 0.3 lux• Cloud cover• Extraneous Light• Luminous Intensity Distribution and angular errors• Photometer- TR28 states ~6% at best

Page 15: PLS 2015: Lumen maintenance testing of outdoor lighting installations

TR28- Luminous Intensity Distribution

Page 16: PLS 2015: Lumen maintenance testing of outdoor lighting installations

TR28- Measurement of Road Lighting Performance on site

(Uncertainties)• What can be controlled or eliminated?• Variation in lamp type • Variation in supply voltage• Variation in lamp mounting and tilt• Accuracy of light meters

• What can’t be accurately controlled:• Access to area • Climate conditions• Obstructions• Extraneous light • Reflections from roadway

Page 17: PLS 2015: Lumen maintenance testing of outdoor lighting installations

CSS Street Lighting Project 2007: Review of Maintenance

Factors• Published in 2008• Collaboration between the County Surveyors’

Society and the lighting industry• Carried out in order to assess if maintenance

factors were accurate

Page 18: PLS 2015: Lumen maintenance testing of outdoor lighting installations

CSS Street Lighting Project 2007: Review of Maintenance

Factors• Sites selected at random

with at least two luminaires from each site• Testing for total lumen

output, carried out in a photometric laboratory• Luminaires tested for

light output before and after cleaning

Page 19: PLS 2015: Lumen maintenance testing of outdoor lighting installations

Laboratory Testing of Luminaire Maintenance

• Uncertainties:• Environmental conditions- temperature can be controlled to within ±0.5°C and

wind speed to within ±0.2 m/s• Moonlight- not applicable• Cloud cover- not applicable• Extraneous Light- not applicable• Luminous Intensity Distribution and angular errors- not applicable because the

light distribution is integrated• Use of spectroradiometer means light measurement errors are >2%• Input voltage can be controlled to an accuracy of ±0.1 V

Page 20: PLS 2015: Lumen maintenance testing of outdoor lighting installations

Laboratory Testing of Luminaire Maintenance

• Benefits-

• Elimination of unknown factors • Repeatable • Much lower level of uncertainty

Page 21: PLS 2015: Lumen maintenance testing of outdoor lighting installations

Any Questions?

01242 701300