pm gearless elevator i_pdf.… · pm gearless elevator 7 pm gearless elevator : iris sigma`s...

24
PM Gearless Elevator IRIS enhancing the value of the building... IRIS maximizing energy savings IRIS enabling environment protections IRIS pursuing space savings IRIS providing ride comfort IRIS ensuring safety & reliability

Upload: others

Post on 18-Sep-2020

30 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: PM Gearless Elevator I_pdf.… · PM Gearless Elevator 7 PM Gearless Elevator : IRIS SIGMA`s cutting-edge gearless technology is favored to suit contemporary buildings. IRIS enables

PM Gearless Elevator

IRIS enhancing the value of the building...

IRIS maximizing energy savings

IRIS enabling environment protections

IRIS pursuing space savings

IRIS providing ride comfort

IRIS ensuring safety & reliability

Page 2: PM Gearless Elevator I_pdf.… · PM Gearless Elevator 7 PM Gearless Elevator : IRIS SIGMA`s cutting-edge gearless technology is favored to suit contemporary buildings. IRIS enables

IRIS represents High Quality, Excellent Aesthetic Design,Short Delivery and Best Service

IRIS is the rainbow goddess in Greek mythology

Truly your elevator partner

2SIGMA Elevator

Page 3: PM Gearless Elevator I_pdf.… · PM Gearless Elevator 7 PM Gearless Elevator : IRIS SIGMA`s cutting-edge gearless technology is favored to suit contemporary buildings. IRIS enables

Groundbreaking low & mid speed elevators

substitute the Geared Machine with highly

efficient Gearless Machine that adopts

Permanent Magnet Synchronous Motor(PMSM)

and exclusive PMSM controller

PM

Ge

arle

ss E

leva

tor I

RIS

: Fe

atu

res

Revolutionary PM Gearless Elevator

�Speed : 1.0 ~ 2.5m/s

�Duty : Up to 1,600kg

�Stops : Up to 32stops (1.0 ~ 1.75m/s)

Up to 40stops (2.0 ~ 2.5m/s)

�Green Elevator- Energy Savings - Environment Protections - Space Savings

�Ride Comfort�Safety and Reliability

Development Concept

Coverage

Main Features

3PM Gearless Elevator

Page 4: PM Gearless Elevator I_pdf.… · PM Gearless Elevator 7 PM Gearless Elevator : IRIS SIGMA`s cutting-edge gearless technology is favored to suit contemporary buildings. IRIS enables

Green Elevator : IRIS

Sigma's goal of green product includes compliance with stringentenvironmental standards.

Accordingly, our approach to an environmentally acceptable productdesign requires careful consideration of the entire product life cyclefrom design to production, and has better solutions for people.

Energy SavingsIRIS pursues cost savings of building power supply by

reducing the capacity of electical facility required for the

operation of the elevator.

High Motor Efficiency

By using permanent magnet(PM) gearless motor,

IRIS improves motor efficiency.

Lower Power Consunptiom

Compact motor design enables IRIS to lower initial

electricity load and power consumption. It also allows

IRIS to reduce heat from the motor.

0.95

0.93

0.91

0.89

0.87

0.85

0.83

0.81

0.79

0.77

0.75

0 10 20 30 40 50 60 70 80

PM Gearless Machine

GearMachine

PM MotorEfficiencyAdvantage of PM

4SIGMA Elevator

Page 5: PM Gearless Elevator I_pdf.… · PM Gearless Elevator 7 PM Gearless Elevator : IRIS SIGMA`s cutting-edge gearless technology is favored to suit contemporary buildings. IRIS enables

PM

Ge

arle

ss E

leva

tor I

RIS

: B

ene

fit

Evironment ProtectionsNo need for lubricant oil

By using PM Gearless, IRIS is free from lubricate oil for the gear box. This enables us

not only to reduce maintenance cost but also to keep machineroom cleaned.

EMC filters

IRIS uses EMC filters which meet CISPR public 22 class. It minimizes interference

from electrical and electronic equipment like home appliances in the building.

Space SavingsCompact machine

Customers may benefit 1/3 space from a smaller size.

Flexible space design and utilization

IRIS enables architects to design building structure

flexibly and use building space efficiently.

5PM Gearless Elevator

Page 6: PM Gearless Elevator I_pdf.… · PM Gearless Elevator 7 PM Gearless Elevator : IRIS SIGMA`s cutting-edge gearless technology is favored to suit contemporary buildings. IRIS enables

6SIGMA Elevator

SPEED

TIMEAdjustableacceleration

Adjustabledecceleration

ConstantSpeed

Final stop

Ride ComfortGearless system

The absense of gearbox allows to eliminate noise from gear

friction. Its coaxial transmission also reduces vibration and

noise effectively.

Controller design for lower noise

Low noise is possible by applying high frequency of 8kHz for

synchronous motor controller.

Smooth Operation

IRIS adopts VVVF(Variable Voltage Variable Frequency)control

with 5th generation IPM and IGBT, and is designed for low

vibration.

Page 7: PM Gearless Elevator I_pdf.… · PM Gearless Elevator 7 PM Gearless Elevator : IRIS SIGMA`s cutting-edge gearless technology is favored to suit contemporary buildings. IRIS enables

7PM Gearless Elevator

PM Gearless Elevator : IRIS

SIGMA`s cutting-edge gearless technology is favored to suitcontemporary buildings.

IRIS enables the value of the building to increase with its newconcepts.

Safety and ReliabilityFlexible CPU

Totally digitally design applying 32bit DSP(Digital Signal

Processor) or PM motor speed control.

Easy Maintenance

Operation history log, mal-function analyzing system

applied.

Guaranteed Reliability

HALT(Highly Accelerated Life Test) on parts to decrease

defects and increase life span of parts.

Full power reserve of motor

A sufficrent power reserve will ensure safer and more

reliable operation of the elevator.

EMI Test(Electro Magnetic Interference)

Vibration and Dropping Test

ESD Test(Electro Static Discharge)

Burst Test

PM

Ge

arle

ss E

leva

tor I

RIS

: B

ene

fit

Page 8: PM Gearless Elevator I_pdf.… · PM Gearless Elevator 7 PM Gearless Elevator : IRIS SIGMA`s cutting-edge gearless technology is favored to suit contemporary buildings. IRIS enables

8SIGMA Elevator

C O O L L I N E

RearView

Ceiling C-32A

OPB CBM-10C

Wall STS Hairline

Door STS Hairline

Handrail HR-04

Floor Deco Tile

Specification

Page 9: PM Gearless Elevator I_pdf.… · PM Gearless Elevator 7 PM Gearless Elevator : IRIS SIGMA`s cutting-edge gearless technology is favored to suit contemporary buildings. IRIS enables

E n t r a n c e D e s i g n

9PM Gearless Elevator

N AT U R A L L I N E

RearView

Ceiling C-HX2

OPB CBM-10C

Wall STS Hairline Etching (DSE-019W)

Door STS Hairline Etching (DSE-019D)

Handrail HR-04

Floor Deco Tile

Specification

Page 10: PM Gearless Elevator I_pdf.… · PM Gearless Elevator 7 PM Gearless Elevator : IRIS SIGMA`s cutting-edge gearless technology is favored to suit contemporary buildings. IRIS enables

10SIGMA Elevator

M O D E R N L I N E

Ceiling C-HX3

OPB CBM-31

CPI CID-10

Wall STS Hairline Etching (DSE-006W)

Door STS Hairline Etching (DSE-006D)

Handrail HR-04

Floor Deco Tile

Specification

RearView

Page 11: PM Gearless Elevator I_pdf.… · PM Gearless Elevator 7 PM Gearless Elevator : IRIS SIGMA`s cutting-edge gearless technology is favored to suit contemporary buildings. IRIS enables

11PM Gearless Elevator

Specification

Jamb�Narrow Jamb in Painted Steel Sheet (No. DSP-004W)

Door�Painted Steel Sheet (No. DSP-004W)

Sill�Extruded Hard Aluminum

Hall Indicator & Button�VID-M432

Specification

Jamb�Wide Jamb in STS Hairline Door�STS Hairline Sill�Extruded Hard Aluminum Hall Indicator & Button�VID-M432

Specification

Jamb�Wide Tapered Jamb with Transom Panel in STS Hairline Door�STS Hairline Etching (No. DSE-019D)Sill�Extruded Hard Aluminum Hall Indicator�HID-A122Hall Button�HBM-S43

E n t r a n c e D e s i g n

Page 12: PM Gearless Elevator I_pdf.… · PM Gearless Elevator 7 PM Gearless Elevator : IRIS SIGMA`s cutting-edge gearless technology is favored to suit contemporary buildings. IRIS enables

12SIGMA Elevator

C e i l i n g

Comfortable Design

Eco Design

Universal Design

Luxury & Stylish Design

C-32A

C-SL4

C-HX2

C-HX3

C-MX3

Page 13: PM Gearless Elevator I_pdf.… · PM Gearless Elevator 7 PM Gearless Elevator : IRIS SIGMA`s cutting-edge gearless technology is favored to suit contemporary buildings. IRIS enables

E n t r a n c e D e s i g n

13PM Gearless Elevator

DSE-***D Etching Pattern for Car / Landing doorDSE-***W Etching Pattern for Car Wall

Actual colors may be different from these prints.

Painted Steel Sheet Color

Etching Pattern

DSP-002W DSP-004W DSP-007W DSP-016C DSP-017C

DSE-001D / DSE-001W DSE-006D / DSE-006WDSE-003D / DSE-003WDSE-002D / DSE-002W

DSE-019D / DSE-019WDSE-015D / DSE-015W

E t c h i n g P a t t e r n & C o l o r s

DSE-001D / DSE-001W DSE-014D / DSE-014W

Page 14: PM Gearless Elevator I_pdf.… · PM Gearless Elevator 7 PM Gearless Elevator : IRIS SIGMA`s cutting-edge gearless technology is favored to suit contemporary buildings. IRIS enables

14SIGMA Elevator

F i x t u r e s

CBM-10C CBM-31

HBM-S43 VID-M432TVID-M432

HBM-S42

CBM-42SH

VID-M422 VID-M422T

Hall Button

Handicapped COP

Car Operating Panel

Page 15: PM Gearless Elevator I_pdf.… · PM Gearless Elevator 7 PM Gearless Elevator : IRIS SIGMA`s cutting-edge gearless technology is favored to suit contemporary buildings. IRIS enables

15PM Gearless Elevator

HLV-C08 HLV-630 HLV-C11HLV-C10

HID-A122

CID-10

CID-12

HID-C132 HID-A132

Hall Position Indicator

Car Position Indicator

Handrail Hall Lantern

HR-08

HR-02

HR-04

Page 16: PM Gearless Elevator I_pdf.… · PM Gearless Elevator 7 PM Gearless Elevator : IRIS SIGMA`s cutting-edge gearless technology is favored to suit contemporary buildings. IRIS enables

16SIGMA Elevator

Te c h n i c a l D a t a

Hoistway & Machine Room Plan Hoistway Section

Overhead, Pit & Machine Room Height

Speed (m/min)

60

90

105

120150

Load (kg)

450 ~ 10001150 ~ 1600450 ~ 10001150 ~ 1600450 ~ 10001150 ~ 1600750 ~ 1600750 ~ 1600

TR ≤100

TR ≤100

TR ≤100

TR ≤130

42004400

4400

4500

51005300

14001400145015001600165019002200

23002000230020002300200020002000

30004500300045003000450045004500

Travel (m) Overhead (mm) PIt Depth (mm) Machine Room Height(mm) Hook Load (kg)

Page 17: PM Gearless Elevator I_pdf.… · PM Gearless Elevator 7 PM Gearless Elevator : IRIS SIGMA`s cutting-edge gearless technology is favored to suit contemporary buildings. IRIS enables

17PM Gearless Elevator

Planning Guide for Dimensions (60m/min)Standard

6

8

9

10

11

13

15

17

20

24

Capacity

Persons

450

550

600

680

750

900

1000

1150

1350

1600

Load(kg)

800

800

800

800

800

900

900

1000

1100

1000

1100

1100

EntranceOpening

(min)

Car InsideSize

AN ×BN

HoistWay Size

Simplex Duplex

Machine Room Size

Simplex Duplex

AH ×BH AH ×BH AM ×BM AM ×BM3600

4200

4500

4900

5250

5750

6150

12300

13100

13900

Machine RoomReaction Load(kg)

R1

2000

2800

3100

3400

3700

4100

4600

8250

8850

9350

R2

4920

7060

7340

7860

8690

9430

10210

17550

18050

19550

Pit ReactionLoad(kg)

R3

3930

5850

6020

6370

6930

7450

8010

13300

13550

14350

R4

1400×850

1400×1030

1400×1100

1400×1250

1400×1350

1600×1350

1600×1500

1800×1500

2000×1350

1800×1700

2000×1500

2000×1750

2150×1600

Car OutsideSize

AS ×BS

1450×1015

1450×1195

1450×1265

1450×1415

1450×1515

1650×1515

1650×1665

1890×1685

2090×1535

1890×1885

2090×1685

2090×1935

2240×1785

1850×1500

1850×1700

1850×1750

1850×1900

1850×2000

2050×2000

2050×2150

2400×2250

2600×2100

2400×2450

2600×2250

2600×2500

2750×2350

3900×1500

3900×1700

3900×1750

3900×1900

3900×2000

4300×2000

4300×2150

5000×2250

5400×2100

5000×2450

5400×2250

5400×2500

5700×2350

1850×1500

1850×1700

1850×1750

1850×1900

1850×2000

2050×2000

2050×2150

2400×2250

2600×2100

2400×2450

2600×2250

2600×2500

2750×2350

3900×1500

3900×1700

3900×1750

3900×1900

3900×2000

4300×2000

4300×2150

5000×2250

5400×2100

5000×2450

5400×2250

5400×2500

5700×2350

1400×850

1400×1030

1400×1100

1400×1250

1400×1350

1600×1350

1600×1500

1800×1500

2000×1350

1800×1700

2000×1500

2000×1750

2150×1600

1450×1015

1450×1195

1450×1265

1450×1415

1450×1515

1650×1515

1650×1665

1890×1685

2090×1535

1890×1885

2090×1685

2090×1935

2240×1785

1850×1500

1850×1700

1850×1750

1850×1900

1850×2000

2050×2000

2050×2150

2400×2250

2600×2100

2400×2450

2600×2250

2600×2500

2750×2350

3900×1500

3900×1700

3900×1750

3900×1900

3900×2000

4300×2000

4300×2150

5000×2250

5400×2100

5000×2450

5400×2250

5400×2500

5700×2350

1850×1500

1850×1700

1850×1750

1850×1900

1850×2000

2050×2000

2050×2150

2400×2250

2600×2100

2400×2450

2600×2250

2600×2500

2750×2350

3900×1500

3900×1700

3900×1750

3900×1900

3900×2000

4300×2000

4300×2150

5000×2250

5400×2100

5000×2450

5400×2250

5400×2500

5700×2350

6

7

8

9

10

12

13

16

18

21

450

525

600

675

800

900

1000

1200

1350

1600

800

800

800

800

800

900

900

1000

1100

1000

1100

1100

3600

4200

4500

4900

5250

5750

6150

12300

13100

13900

2000

2800

3100

3400

3700

4100

4600

8250

8850

9350

4920

7060

7340

7860

8690

9430

10210

17550

18050

19550

3930

5850

6020

6370

6930

7450

8010

13300

13550

14350

EN Code

Malaysia Code

Unit : mm

1400×850

1400×1030

1400×1100

1400×1250

1400×1350

1600×1350

1600×1500

1800×1500

2000×1350

1800×1700

2000×1500

2000×1750

2150×1600

1450×1015

1450×1195

1450×1265

1450×1415

1450×1515

1650×1515

1650×1665

1890×1685

2090×1535

1890×1885

2090×1685

2090×1935

2240×1785

1850×1500

1850×1700

1850×1750

1850×1900

1850×2000

2050×2000

2050×2150

2400×2250

2600×2100

2400×2450

2600×2250

2600×2500

2750×2350

3900×1500

3900×1700

3900×1750

3900×1900

3900×2000

4300×2000

4300×2150

5000×2250

5400×2100

5000×2450

5400×2250

5400×2500

5700×2350

1850×1500

1850×1700

1850×1750

1850×1900

1850×2000

2050×2000

2050×2150

2400×2250

2600×2100

2400×2450

2600×2250

2600×2500

2750×2350

3900×1500

3900×1700

3900×1750

3900×1900

3900×2000

4300×2000

4300×2150

5000×2250

5400×2100

5000×2450

5400×2250

5400×2500

5700×2350

6

8

9

10

11

13

15

17

20

23

450

545

615

680

750

885

1025

1160

1365

1565

800

800

800

800

800

900

900

1000

1100

1000

1100

1100

3600

4200

4500

4900

5250

5750

6150

12300

13100

13900

2000

2800

3100

3400

3700

4100

4600

8250

8850

9350

4920

7060

7340

7860

8690

9430

10210

17550

18050

19550

3930

5850

6020

6370

6930

7450

8010

13300

13550

14350

Page 18: PM Gearless Elevator I_pdf.… · PM Gearless Elevator 7 PM Gearless Elevator : IRIS SIGMA`s cutting-edge gearless technology is favored to suit contemporary buildings. IRIS enables

18SIGMA Elevator

Te c h n i c a l D a t a

Planning Guide for Dimensions (90, 105m/min)

Standard

8

9

10

11

13

15

17

20

24

Capacity

Persons

550

600

680

750

900

1000

1150

1350

1600

Load(kg)

800

800

800

800

900

900

1000

1100

1000

1100

1100

EntranceOpening

(min)

Car InsideSize

AN ×BN

HoistWay Size

Simplex Duplex

Machine Room Size

Simplex Duplex

AH ×BH AH ×BH AM ×BM AM ×BM4200

4500

4900

5250

5750

6150

12300

13100

13900

Machine RoomReaction Load(kg)

R12800

3100

3400

3700

4100

4600

8250

8850

9350

R27060

7340

7860

8690

9430

10210

17550

18050

19550

Pit ReactionLoad(kg)

R35850

6020

6370

6930

7450

8010

13300

13550

14350

R4

1400×1030

1400×1100

1400×1250

1400×1350

1600×1350

1600×1500

1800×1500

2000×1350

1800×1700

2000×1500

2000×1750

2150×1600

Car OutsideSize

AS ×BS

1450×1195

1450×1265

1450×1415

1450×1515

1650×1515

1650×1665

1890×1685

2090×1535

1890×1885

2090×1685

2090×1935

2240×1785

1850×1700

1850×1750

1850×1900

1850×2000

2050×2000

2050×2150

2400×2250

2600×2100

2400×2450

2600×2250

2600×2500

2750×2350

3900×1700

3900×1750

3900×1900

3900×2000

4300×2000

4300×2150

5000×2250

5400×2100

5000×2450

5400×2250

5400×2500

5700×2350

1850×1700

1850×1750

1850×1900

1850×2000

2050×2000

2050×2150

2400×2250

2600×2100

2400×2450

2600×2250

2600×2500

2750×2350

3900×1700

3900×1750

3900×1900

3900×2000

4300×2000

4300×2150

5000×2250

5400×2100

5000×2450

5400×2250

5400×2500

5700×2350

1400×1030

1400×1100

1400×1250

1400×1350

1600×1350

1600×1500

1800×1500

2000×1350

1800×1700

2000×1500

2000×1750

2150×1600

1450×1195

1450×1265

1450×1415

1450×1515

1650×1515

1650×1665

1890×1685

2090×1535

1890×1885

2090×1685

2090×1935

2240×1785

1850×1700

1850×1750

1850×1900

1850×2000

2050×2000

2050×2150

2400×2250

2600×2100

2400×2450

2600×2250

2600×2500

2750×2350

3900×1700

3900×1750

3900×1900

3900×2000

4300×2000

4300×2150

5000×2250

5400×2100

5000×2450

5400×2250

5400×2500

5700×2350

1850×1700

1850×1750

1850×1900

1850×2000

2050×2000

2050×2150

2400×2250

2600×2100

2400×2450

2600×2250

2600×2500

2750×2350

3900×1700

3900×1750

3900×1900

3900×2000

4300×2000

4300×2150

5000×2250

5400×2100

5000×2450

5400×2250

5400×2500

5700×2350

7

8

9

10

12

13

16

18

21

525

600

675

800

900

1000

1200

1350

1600

800

800

800

800

900

900

1000

1100

1000

1100

1100

4200

4500

4900

5250

5750

6150

12300

13100

13900

2800

3100

3400

3700

4100

4600

8250

8850

9350

7060

7340

7860

8690

9430

10210

17550

18050

19550

5850

6020

6370

6930

7450

8010

13300

13550

14350

EN Code

Malaysia Code

Unit : mm

1400×1030

1400×1100

1400×1250

1400×1350

1600×1350

1600×1500

1800×1500

2000×1350

1800×1700

2000×1500

2000×1750

2150×1600

1450×1195

1450×1265

1450×1415

1450×1515

1650×1515

1650×1665

1890×1685

2090×1535

1890×1885

2090×1685

2090×1935

2240×1785

1850×1700

1850×1750

1850×1900

1850×2000

2050×2000

2050×2150

2400×2250

2600×2100

2400×2450

2600×2250

2600×2500

2750×2350

3900×1700

3900×1750

3900×1900

3900×2000

4300×2000

4300×2150

5000×2250

5400×2100

5000×2450

5400×2250

5400×2500

5700×2350

1850×1700

1850×1750

1850×1900

1850×2000

2050×2000

2050×2150

2400×2250

2600×2100

2400×2450

2600×2250

2600×2500

2750×2350

3900×1700

3900×1750

3900×1900

3900×2000

4300×2000

4300×2150

5000×2250

5400×2100

5000×2450

5400×2250

5400×2500

5700×2350

8

9

10

11

13

15

17

20

23

545

615

680

750

885

1025

1160

1365

1565

800

800

800

800

900

900

1000

1100

1000

1100

1100

4200

4500

4900

5250

5750

6150

12300

13100

13900

2800

3100

3400

3700

4100

4600

8250

8850

9350

7060

7340

7860

8690

9430

10210

17550

18050

19550

5850

6020

6370

6930

7450

8010

13300

13550

14350

Page 19: PM Gearless Elevator I_pdf.… · PM Gearless Elevator 7 PM Gearless Elevator : IRIS SIGMA`s cutting-edge gearless technology is favored to suit contemporary buildings. IRIS enables

19PM Gearless Elevator

Standard

EN Code

Malaysia Code

Planning Guide for Dimensions(120, 150m/min)

EntranceOpening

(mm)

Car InsideSize

Car OutsideSize

Hoistway SizeSimplex Duplex

Machine Room SizeSimplex Duplex

Machine RoomReaction Load(kg)

Pit ReactionLoad(kg)

11

13

15

17

20

24

750

900

1000

1150

1350

1600

800

900

900

1000

1100

1000

1100

1100

1400×1350

1600×1350

1600×1500

1800×1500

2000×1350

1800×1700

2000×1500

2000×1750

2150×1600

1490×1535

1690×1535

1690×1685

1890×1685

2090×1535

1890×1885

2090×1685

2090×1935

2240×1785

2000×2100

2200×2100

2200×2250

2400×2250

2600×2100

2400×2450

2600×2250

2600×2500

2750×2350

AH ×BHAN ×BN AS ×BS

4200×2100

4600×2100

4600×2250

5000×2250

5400×2100

5000×2450

5400×2250

5400×2500

5700×2350

AH ×BH

2000×2100

2200×2100

2200×2250

2400×2250

2600×2100

2400×2450

2600×2250

2600×2500

2750×2350

AM ×BM

4200×2100

4600×2100

4600×2250

5000×2250

5400×2100

5000×2450

5400×2250

5400×2500

5700×2350

AM ×BM

11000

11000

11650

12300

13100

13900

R1

7550

7550

7850

8250

8850

9350

R2

10000

13250

13950

17550

18050

19550

R3

8300

10100

10550

13300

13550

14350

R4

Capacity

Persons Load(kg)

Unit : mm

1490×1535

1690×1535

1690×1685

1890×1685

2090×1535

1890×1885

2090×1685

2090×1935

2240×1785

10

12

13

16

18

21

800

900

1000

1200

1350

1600

800

900

900

1000

1100

1000

1100

1100

1400×1350

1600×1350

1600×1500

1800×1500

2000×1350

1800×1700

2000×1500

2000×1750

2150×1600

2000×2100

2200×2100

2200×2250

2400×2250

2600×2100

2400×2450

2600×2250

2600×2500

2750×2350

4200×2100

4600×2100

4600×2250

5000×2250

5400×2100

5000×2450

5400×2250

5400×2500

5700×2350

2000×2100

2200×2100

2200×2250

2400×2250

2600×2100

2400×2450

2600×2250

2600×2500

2750×2350

4200×2100

4600×2100

4600×2250

5000×2250

5400×2100

5000×2450

5400×2250

5400×2500

5700×2350

11000

11000

11650

12300

13100

13900

7550

7550

7850

8250

8850

9350

10000

13250

13950

17550

18050

19550

8300

10100

10550

13300

13550

14350

1490×1535

1690×1535

1690×1685

1890×1685

2090×1535

1890×1885

2090×1685

2090×1935

2240×1785

11

13

15

17

20

23

750

885

1025

1160

1365

1565

800

900

900

1000

1100

1000

1100

1100

1400×1350

1600×1350

1600×1500

1800×1500

2000×1350

1800×1700

2000×1500

2000×1750

2150×1600

2000×2100

2200×2100

2200×2250

2400×2250

2600×2100

2400×2450

2600×2250

2600×2500

2750×2350

4200×2100

4600×2100

4600×2250

5000×2250

5400×2100

5000×2450

5400×2250

5400×2500

5700×2350

2000×2100

2200×2100

2200×2250

2400×2250

2600×2100

2400×2450

2600×2250

2600×2500

2750×2350

4200×2100

4600×2100

4600×2250

5000×2250

5400×2100

5000×2450

5400×2250

5400×2500

5700×2350

11000

11000

11650

12300

13100

13900

7550

7550

7850

8250

8850

9350

10000

13250

13950

17550

18050

19550

8300

10100

10550

13300

13550

14350

Page 20: PM Gearless Elevator I_pdf.… · PM Gearless Elevator 7 PM Gearless Elevator : IRIS SIGMA`s cutting-edge gearless technology is favored to suit contemporary buildings. IRIS enables

20SIGMA Elevator

Te c h n i c a l D a t a

Speed(m/min)

CapacityLoad(kg)

MotorCapacity(kW) Simplex Duplex

MCCB Capacity(A) Transformer Capa.(kVA) Lead-in Wire Size(mm2)Simplex Duplex Simplex Duplex

Earth WireSize(mm2)

StartingPower(kVA/set))Persons

60

90

105

6891011131517202489101113151720248910111315172024

450550600680750900100011501350160055060068075090010001150135016005506006807509001000115013501600

5.55.55.55.55.56.76.711.111.111.18.88.88.88.810.710.717.717.717.7

9.7 / 9.99.7 / 9.99.7 / 9.99.7 / 9.9

11.711.719.419.419.4

35353540505050608080505060606080100100125808080100100100100125125

60506080100100100125125150100100125125125150200200250125125125150150200200225250

16161620252525324040252532323240505063323232404050506363

323232405050506363805050636363801001001256363638080100100125140

6.06.06.26.97.88.49.110.912.314.18.18.69.510.811.612.615.117.219.89.910.511.513.114.115.317.319.722.6

11.911.912.513.815.616.818.121.924.728.216.217.219.021.523.125.130.234.339.619.821.023.026.228.230.634.539.345.3

8.08.08.08.08.08.08.016.016.016.08.08.08.016.016.016.022.022.022.016.016.016.016.016.022.022.022.038.0

16.016.016.016.016.016.022.022.038.038.022.022.022.022.022.038.038.038.050.022.038.038.038.038.038.038.050.050.0

4.04.04.04.04.04.04.06.06.06.04.04.04.06.06.06.08.08.08.06.06.06.06.06.08.08.08.016.0

6.06.06.06.06.06.08.08.016.016.08.08.08.08.08.016.016.016.025.08.016.016.016.016.016.016.025.025.0

6666666666666666666666666666

645785860975114512851430164519302285118012851460171519302145246528953430137515001700200022502500287533754000

7.37.37.78.710.010.911.914.716.819.510.511.212.614.515.717.221.024.028.013.214.115.618.019.521.324.227.832.3

Power Supply Plan

Speed 60, 90, 105m/min

Heat Output(kcal / H)

Speed(m/min)

Capacity

Load(kg)

MotorCapacity

(kW) Simplex Duplex Triplex Fourplex Simplex Duplex Triplex Fourplex Simplex Duplex Triplex Fourplex

MCCB Capacity of Building(A) Power Supply Capacity(kVA) Lead-in Wire Size(mm2) Earth WireSize

(mm2)

HeatOutput

(kcal / H)

StartingPower

(kVA/set)Persons

120

150

111315172024111315172024

75090010001150135016007509001000115013501600

1113.513.516

18.522

13.517172023

27.5

60607510010012575175100125125150

4040505060755050607575100

125125150175200225150150175200225300

75100100100125150100100125125150175

200200200250300350225225250300350400

100125125150175200125150150175200250

250250300350400500300300350400550600

125125150175200225150150175200225300

131416182125161820232631

252731364250313539455262

343842485767424752607184

394348556577485460698196

383838383850383838505038

8888814888141414

60606010012515060100100125150150

141414223038142222303838

100100150150200200150150200200250250

222230303850303038506060

150200200200250250200200250250325325

223030385080303850608080

8888814888141414

228525702860330038604575286032153575411048255715

252729323641323538424754

Speed 120, 150 m/min

220V400V

220V400V

Page 21: PM Gearless Elevator I_pdf.… · PM Gearless Elevator 7 PM Gearless Elevator : IRIS SIGMA`s cutting-edge gearless technology is favored to suit contemporary buildings. IRIS enables

21PM Gearless Elevator

� Standard � Option

FEATURES DESCRIPTION

Technical Features

Attendant Operation

Independent Operation

Back-up operation

Safe Drive Operation

Car Call Cancellation

Automatic Turn-Off of

Car Light & Fan

Automatic Bypass

Overload Holding Stop

(110% of rated load)

Detection of Jammed

Hall Button

Car Door Safety Edge

Micro Levelling

N-Plex Operation

Non-Stop Operation

Parking Operation

VIP Operation

Emergency Power

Operation

Fire return operation

Firemen Operation

Anti-nuisance Operation

Door Nudging

Voice Synthesizer

Door Photo Sensor

The operating mode of an elevator can be changed from the normal automatic operation to theattendant service by an attendant switch.Key switch in the car operating panel will cancel any existing car calls and hold the door open at thelanding position. During independing operation, the car will respond only to car calls. When Electrical transmission device between hall call and control panel comes into the abnormalcondition and it lasts during some period, elevator control device is converted to Back-up operationautomatically. Then, the elevator moves in sequence up and down repeatedly from top to bottom floorto service every other floor which is in normal condition.When a car stops between floors due to mechanical malfunction, it will descend to the nearest floorat a low speed and hold the doors open after checking all safety measures.Allows cancellation of an incorrectly registered car call. If you push a wrong floor button in the car, youcan cancel it by pressing that floor button one more time.Car illumination and fan are turned off automatically in case there is no hall call or car call, this savesenergy.A fully-loaded car ( More than 80% of rated load) bypasses hall calls in order to maintain maximumoperational efficiency.When the number of passengers exceeds the normal capacity, a buzzer sounds and the elevatorremains stopped at that floor. When the excessive number of passengers disembark, the buzzerstops, the elevator doors close, and operation continues.If a hall button is jammed mechanically, the hall call will be automatically bypassed after being servedonce, until the program is resolved.Extending the full height of the car door, this decice causes the doors to return to the fully openposition, should the door encounter a person or obstacle while closing.An automatic two way levelling device is provided to maintain the elevator car level with the landing,regardless of elevator load or direction of travel.It can control up to 4 sets of elevators to optimize allocation of hall calls.Specific floors which are memorized in control panel can be set to disable using switch on caroperating panel or in security room.The elevator can be automatically parked at the predetermned floor with its door closed, as well asturn off the lights and ventillation.The specified elevator is controlled by the special call buttons provided only for VIP elevatorIf normal building power supply fails and the building provides emergency power to the controller(s),one elevator at a time will proceed to the lowest landing where it will stop with doors open and withall of its power and operating circuit in an inoperative standby condition. In case of fire, every car should be returned to the specified floor in order to evacuate pasengers tosafety.In case of fire, a firemen can use the elevator which is stopped at the specified floor in order tosupport firemen for fire-fighting.In case of substantial difference between the number of calls registered on the car operating paneland actual load in the elevator, the elevator prevents unnecessary operation by cancelling allregistered calls when it arrives at the nearest floor.When the doors remain open for more than the fixed door open time, this feature closes the doors atreduced closing speed with the buzzer sounding.This system provides riding passengers with audio information about car operation such as directionof travel, landing floor, etc.The doors reverse to fully open position if the light ray unit detects an obstacle when the doors areclosing.

Operation Functions

Page 22: PM Gearless Elevator I_pdf.… · PM Gearless Elevator 7 PM Gearless Elevator : IRIS SIGMA`s cutting-edge gearless technology is favored to suit contemporary buildings. IRIS enables

22SIGMA Elevator

Te c h n i c a l D a t a

The works below are not included in the elevator installation work and should be carried out bybuilding contractors in accordance with our drawings, relevant international or local codes andregulations.

Hoistway

�A properly framed and enclosed hoistway, including any venting as requried by the governing code or authority.�A dry pit constructed to the elevator manufacturer's specifications to reinforce or sustain any vertical forces on

the guide rails and impacted loads from the car and counterweight buffers.�A metal sill angle or concrete haunch across the full width of the hoistway at each elevator landing.�Provision of steel bars to fix jamb around the entrance of each floor.�All cutting, including cutouts to accommodate hall singal fixtures, patching, painting of walls, floors, or partitions,

together with finish painting of entrance doors and frames, if required.�Provision of entrance or ladder for pit access�Supply and installation of fascia plate.�Installation of emergency exits and electric wiring in blind sections of hoistway where required.�The tolerance of perpendicular line over the whole hoistway height must not exceed ±30mm.�A waterproof outlet and light fixture in the elevator pit area with the light switch being located adjacent to

the access door or ladder.�Suitable light fixture and convenience outlet in the pit with a light switch adjacent to the access door or ladder.

The receptacles shall have protection for ground fault circuit interrupter.

Machine Room

�Provision of wiring between controller and building management system.�A construction hoisting beam or hook, if required, with the correct location and size as determined by the elevator

contractor for each hoistway.�Noise insulation should be installed between machine room and adjacent residential area.�A suitable machine room with legal access, ventilation and concrete floor.

The temperature in the machine room should be maintained between 5℃ and 40℃.Relative humidity should not exceed 90%(monthly) and 95%(daily) non-condensing.Ventilation fan or Air conditioner should be provided as per heat dissipation by the elevator contractor.�The size of entrance shall be Min.1000mm(W) x 2000mm(H).�Installation of lead-in wire and earth wire between building main power board and machine room incoming

distribution board. However, machine room lighting source supply shall be installed separately.�Provision of suitable light fixture and convenience outlets in the machine room

Miscellaneous

�Wiring and piping between monitoring system.�Machine room and hoistway shall be free of dust or harmful gas.�All electric power for lighting, tools, welding, etc during installation.�All single phase receptacles installed in machine rooms, pits, and machinery spaces shall have ground fault circuit

interrupter protection.�Fire detector for fire emergency operation.�A secured area for stroage of elevator equipment and materials during installtion.

Work by Others

Page 23: PM Gearless Elevator I_pdf.… · PM Gearless Elevator 7 PM Gearless Elevator : IRIS SIGMA`s cutting-edge gearless technology is favored to suit contemporary buildings. IRIS enables

PM Gearless Elevator

233PM Gearless Elevator

Page 24: PM Gearless Elevator I_pdf.… · PM Gearless Elevator 7 PM Gearless Elevator : IRIS SIGMA`s cutting-edge gearless technology is favored to suit contemporary buildings. IRIS enables

SIGMA constantly endeavors to improve products so that information in this catalog is subject to change without notice. 2006. 11 Printed in Korea

PM Gearless Elevator