Technical DatasheetTD 00029E/24/EN/01.13
• Flush-mounted process connections with metal diaphragm
•Up to four times overload resistant and longterm stability
• FDA compliant fill oil•Materials in contact with process
made of 316L SS with a surface finish of Ra ≤ 0.8 µm
Complete product information:www.e-direct.us/pmp135
Specs at a glance:
•Product: Liquids, vapors and gases in the food industry
•Output: 4 to 20 mA•Accuracy: < 0.5 % •Product temperature:
-13 to +212 °F (-25 to +100 °C), +275 °F (135 °C ) for 1 h
•Measuring range (limits): 0 to 15 psi (1 bar), 0 to 600 psi (40 bar)
Hygienic pressure transmitter
CerabarTPMP135
$ 383.00
4 to 20 mA
Power supply(e.g. RN221N)
p
CerabarTPMP135 2Contact
Overview Technical data Dimensions
Electrical connection Accessories Price tableGo to shop
Application / Function
Application The Cerabar T PMP135 is a pressure transmitter designed for measuring absolute and gauge pressures in hygienic applications within in the food processing and pharmaceutical industries.
ApplicationexampleFunction The process pressure acting on the metallic separating diaphragm of the sensor is transmitted to a resistance bridge via a fill fluid. The change in the output voltage of the bridge is proportional to the pressure and can be measured directly.
Cerabar T pressure transducer with 4 to 20 mA output and auxiliary power supply, such as RN221N.
CerabarTPMP135 3Contact
Application / FunctionOverview Dimensions
Electrical connection Accessories Price tableGo to shop
Technical data
Technicaldata
OutputOutput signal 4 to 20 mALoad RB ≤ (US - 12 V)/0.02 A (US = power supply)
AccuracyNon-linearity ≤ 0.5 % including hysteresis and non-
reproducibilityReference operating conditions
As per DIN IEC 60770, T = 77 °F (25 °C)
Effect of ambient temperature
In relation to nominal valuezero point: typ. 0.2 % of URL/10 K;Range: typ. 0.2 % of URL/10 K
Long-term drift ≤ 0.15 % per year
Operating conditionsMaterial temperature -13 to +212 °F (-25 to +100 °C),
+275 °F (135 °C) for 1 hAmbient temperature -13 to +158 °F (-25 to +70 °C)
Ex i: -13 to +149 °F (-25 to +65 °C)Storage temperature -40 to +185 °F (-40 to +85 °C)Climate class 4 Z: with Z = 158 °F (70 °C) as per VDI/VDE
3540Mounting position Any orientation. Orientation dependent zero
shift can be corrected using potentiometer adjustments
Degree of protection Plug PG 11 or ½" NPT: IP 65Plug M12×1 when using gauge pressure sensors: IP 65Plug M12×1 when using absolute pressure sensors: IP 68 (1 m (3.3 ft) water column)Cable: IP 68 (1 m (3.3 ft) water column)
Limiting medium pressure range
Maximum overload resistance, refer to measuring range Vacuum resistance up to 10 mbarabs
Vibration resistance 4M5 as per DIN EN 60721-3EMC According to EN 61326
Mechanical constructionProcess connection ½", 1" Clamp; G1A with tapered metallic seal
or with sealing surface for flush-mounted installation
Materials Process connections and diaphragm: 316L SS; wetted surface smoothness: Ra ≤ 0.8 µm; Transmitter housing: 304 SS Cable outer covering: polyurethane (PUR) Fill fluid: Neobee M20
Power supply Ub
Supply voltage 12 to 30 V DCResidual ripple Max. 5 %
ApprovalsEx approval ATEX II 1/2 G EEx ib IIC T6
ATEX II 2 G EEx ib IIC T63A
CerabarTPMP135 4Contact
Application / FunctionOverview Technical data
Price tableGo to shopAccessoriesElectrical connection
Dimensions
Dimensions(ininches) Electricalconnection Accessory:DisplayPHX20 / PHX21
12...30 V
4...20 mA
1+ 2–
1
2
–
+
Plug ISO 4400/M16 or ½" NPT
1.65
1.65
(Dimensions in inches)
1.89
Technical dataDisplay 4 digits, red LED, loop powered to use in
4 to 20 mA loops, angular connector DIN 43650 7.62 mm (0.3") display height, turnable in angle of 90°
Display range -1 999 to +9 999, programmable via two keysProtection class IP 65Material Plastic PA6 GF30, front screen PMMAVoltage drop ≤ 5 V (equivalent burden of max. 250 Ω)Approval PHX21: ATEX II 2G
1.46
3.11
Ø 1.08
2.05
Plug M16,IP 65
Housing
Installation according to instruction manual.
1.30
1.30
Ø 0.68Ø 0.68
Ø 2.00
Ø 1.71
Ø 2.52
Tri-Clamp 1" to 1½" (ISO 2852)
Process connections
Tri-Clamp 2" (ISO 2852)
M
Ø 2.22
CerabarTPMP135 5Contact
Application / FunctionOverview Technical data Dimensions
Electrical connection AccessoriesGo to shopPrice table
Pricetable
*
Moreproductstocompleteyourmeasuringpoint…
Cerabar T PMP135; Output: 4-20mA SIL Order no. Price/pcs. in USDElectrical Connection Process Connection 1 to 5 6 to 10 11 to 35Plug ISO4400 NPT½, IP65 NEMA4X
Tri-Clamp ISO2852 DN25-38 (1...1½"), 316L, DIN32676 DN25-40, EHEDG, 3A
PMP135-A2G01 435.00 405.00 383.00
Tri-Clamp ISO2852 DN40-51 (2"), 316L, DIN32676 DN50, EHEDG, 3A
PMP135-A2H01 435.00 405.00 383.00
Plug and cable to be ordered as ‘accessory’* Please add code for measuring range.
Accessories Order no. Price/pcs. in USDDisplay PHX20 52022914 222.00Display PHX21 52022915 265.00Weld-in adapter G1, d=60, 316L 52001051 88.00Prices valid until 09.30.2013 in U.S. dollars per unit (not including shipping and applicable sales tax).See Endress+Hauser, Inc. Terms and Conditions of Sale for shipping, tax, and payment terms.
Complete product information:www.e-direct.us/pmp135
Measuring Range
Code Gauge pressure OverloadA1G 0 to 1 bar, 0 to 100 kPa 4 bar, 400 kPaA1H 0 to 1.6 bar, 0 to 160 kPa 6.4 bar, 640 kPaA1N 0 to 2.5 bar, 0 to 250 kPa 10 bar, 1 MPaA1Q 0 to 4 bar, 0 to 400 kPa 16 bar, 1.6 MPaA1R 0 to 6 bar, 0 to 600 kPa 24 bar, 2.4 MPaA1S 0 to 10 bar, 0 to 1 MPa 40 bar, 4 MPaA1T 0 to 16 bar, 0 to 1.6 MPa 64 bar, 6.4 MPaA1W 0 to 25 bar, 0 to 2.5 MPa 100 bar, 10 MPaA1X 0 to 40 bar, 0 to 4 MPa 160 bar, 16 MPaQ4H 0 to 15 psi 60 psiQ4K 0 to 30 psi 150 psiQ4N 0 to 50 psi 240 psiQ4R 0 to 150 psi 600 psiQ4S 0 to 300 psi 1500 psiQ4T 0 to 500 psi 2400 psi
Code Absolute pressure OverloadA2G 0 to 1 bar, 0 to 100 kPa 4 bar, 400 kPaA2H 0 to 1.6 bar, 0 to 160 kPa 6.4 bar, 640 kPaA2N 0 to 2.5 bar, 0 to 250 kPa 10 bar, 1 MPaA2Q 0 to 4 bar, 0 to 400 kPa 16 bar, 1.6 MPaA2R 0 to 6 bar, 0 to 600 kPa 24 bar, 2.4 MPaA2S 0 to 10 bar, 0 to 1 MPa 40 bar, 4 MPaA2T 0 to 16 bar, 0 to 1.6 MPa 64 bar, 6.4 MPaA2W 0 to 25 bar, 0 to 2.5 MPa 100 bar, 10 MPaA2X 0 to 40 bar, 0 to 4 MPa 160 bar, 16 MPaR4H 0 to 15 psi 60 psiR4K 0 to 30 psi 150 psiR4N 0 to 50 psi 240 psiR4R 0 to 150 psi 600 psiR4S 0 to 300 psi 1500 psiR4T 0 to 500 psi 2400 psi
*
CompactthermometerEasytemp TMR35
PointlevelswitchLiquiphant T FTL20H
FieldindicatorRIA16
Application / FunctionOverview Technical data Dimensions
Electrical connectionGo to shopContactAccessories Price table
Contact
E-directEndress+Hauser, Inc.2350 Endress PlaceGreenwood, IN 46143
Direct order
Internet www.e-direct.usby phone 888- EH-DIRECT
(343-4732)per Fax 317-535-8498E-Mail [email protected]