pod used as a filtering method
DESCRIPTION
Decompose the flow, and preserve the highest energy levels (Here upper 10%). Calculated Instantaneous velocity vectors. Subtract the Mean image. Raw Images. POD used as a filtering method. Example: Poorly seeded Helium Jet. Holes in gappy dataset - PowerPoint PPT PresentationTRANSCRIPT
![Page 1: POD used as a filtering method](https://reader030.vdocuments.net/reader030/viewer/2022020208/56814d07550346895dba3927/html5/thumbnails/1.jpg)
Slide 1 Den Haag September 2007
POD used as a filtering methodExample: Poorly seeded Helium Jet
Raw ImagesSubtract the Mean image
Calculated Instantaneous
velocity vectors
Decompose the flow, and preserve the highest energy levels (Here
upper 10%)
![Page 2: POD used as a filtering method](https://reader030.vdocuments.net/reader030/viewer/2022020208/56814d07550346895dba3927/html5/thumbnails/2.jpg)
Slide 2 Den Haag September 2007
POD as filtering• Holes in gappy dataset
• Poorly seeded TR measurements often have that
VectorsImage POD Projection (90% of energy)
![Page 3: POD used as a filtering method](https://reader030.vdocuments.net/reader030/viewer/2022020208/56814d07550346895dba3927/html5/thumbnails/3.jpg)
Slide 3 Den Haag September 2007
POD as filtering• Example – a jet where the surrounding air has not been seeded
![Page 4: POD used as a filtering method](https://reader030.vdocuments.net/reader030/viewer/2022020208/56814d07550346895dba3927/html5/thumbnails/4.jpg)
Slide 4 Den Haag September 2007
EndoscopesSetup for 3D PIV
Two different endoscopes:
-Normal end
-45 slanted end
![Page 5: POD used as a filtering method](https://reader030.vdocuments.net/reader030/viewer/2022020208/56814d07550346895dba3927/html5/thumbnails/5.jpg)
Slide 5 Den Haag September 2007
Endoscopic light sheet optics
![Page 6: POD used as a filtering method](https://reader030.vdocuments.net/reader030/viewer/2022020208/56814d07550346895dba3927/html5/thumbnails/6.jpg)
Slide 6 Den Haag September 2007
300
310
320
330
340
350
360
370
380
390
400
410
0.5 1 1.5
0.5
0.6
0.7
0.8
0.9
1
1.1
1.2
1.3
1.4
1.5
ResultsRotor - Position 1in-plane velocity
-50
-40
-30
-20
-10
0
10
20
30
40
50
0.5 1 1.5
0.5
0.6
0.7
0.8
0.9
1
1.1
1.2
1.3
1.4
1.5
Rotor - Position 1out-of--plane velocity
Rotor-Position 1Instantaneous Vortivcity
More details about the measurements in a transonic test turbine can be found in: Lang et al., "Stereoscopic particle image velocimetry in a transonic turbine stage", Experiments in Fluids 32, 2002, pp 700-709
![Page 7: POD used as a filtering method](https://reader030.vdocuments.net/reader030/viewer/2022020208/56814d07550346895dba3927/html5/thumbnails/7.jpg)
Slide 7 Den Haag September 2007
• Slow, low-turbulentwater flow
• 60 µm polyamide particles
• 20W AR-Ion laser w. scanning mirror
• NanoSense camera
• Frame rate ~100 Hz
• Measuring distance 3.7m(1.2 m in water)
• Measuring area820 x 1000 mm
I.e. almost 1 m2 !!!
Large area TR-PIV
![Page 8: POD used as a filtering method](https://reader030.vdocuments.net/reader030/viewer/2022020208/56814d07550346895dba3927/html5/thumbnails/8.jpg)
Slide 8 Den Haag September 2007
Understanding tip vortices in detailswith PIV measurements in water
x/b=6.80.2 nm
K. & C. Huenecke, Airbus
x/b=30.00.9 nm
x/b=63.02.0 nm
1962 CTA measurements in open air,waiting for the fly-by of the aircraft
Wingtip vortices, then and now
![Page 9: POD used as a filtering method](https://reader030.vdocuments.net/reader030/viewer/2022020208/56814d07550346895dba3927/html5/thumbnails/9.jpg)
Slide 9 Den Haag September 2007
Laser housing on vertical traverse
1 - 6 m down
10 m laserumbilical
Power supplyon platformTowed
aircraftmodel
Cross section of HSVA tank
Submerged PIV for large towing tank
![Page 10: POD used as a filtering method](https://reader030.vdocuments.net/reader030/viewer/2022020208/56814d07550346895dba3927/html5/thumbnails/10.jpg)
Slide 10 Den Haag September 2007
Vector Field Vorticity
Click on the picture
![Page 11: POD used as a filtering method](https://reader030.vdocuments.net/reader030/viewer/2022020208/56814d07550346895dba3927/html5/thumbnails/11.jpg)
Slide 11 Den Haag September 2007
Trajectory of the Vortex Core
y-z
![Page 12: POD used as a filtering method](https://reader030.vdocuments.net/reader030/viewer/2022020208/56814d07550346895dba3927/html5/thumbnails/12.jpg)
Slide 12 Den Haag September 2007
Vector Field and Velocity Magnitude
Click on the picture
![Page 13: POD used as a filtering method](https://reader030.vdocuments.net/reader030/viewer/2022020208/56814d07550346895dba3927/html5/thumbnails/13.jpg)
Slide 13 Den Haag September 2007
Thank you!