porewater collection and risk evaluation 27 th alabama water resources conference orange beach, al...
TRANSCRIPT
Porewater Collection and Risk Evaluation
27th Alabama Water Resources Conference
Orange Beach, AL
Jacob Gruzalski
Environmental Standards, Inc.
Acknowledgements
I would like to thank the following individuals for their significant contributions and input: Dr. Bill Rogers - Tennessee Valley Authority Dr. Neil Carriker - Tennessee Valley Authority Mr. Rock Vitale - Environmental Standards, Inc. Mr. David Thal - Environmental Standards, Inc. Dr. James Markwiese - Environmental
Standards, Inc.
2
Objectives
Define Porewater Reason for Porewater Collection and Analysis Importance of Proper Porewater Sampling Overview of Case Studies Conclusions
3
Sediment
Sediment is naturally occurring material that is broken down by processes of weathering and erosion and transported by wind, water, or ice.
Sediment is comprised of an aqueous and solid phase.
5
Porewater – Definition
Porewater is the water filling the spaces between grains of the solid phase of sedimento Sand, silt, and clay
Porewater is the aqueous phase of sediment
By definition porewater cannot exist separate from the solid phase of sediment in the environment
6
Porewater – Ecological Significance
Sediment porewater is a primary exposure pathway of contaminants to the benthic community.
These organisms then have the potential of introducing contaminants into the food chain (fish, aerial feeding birds).
7
Why analyze porewater?
To collect complete information on sediment contamination
Chemical concentration profiles in sediment porewater are widely used in studies and investigations into contaminant exposure, fate, and transport.
To evaluate potential exposure pathwayso Bioavailable vs. Totalo Line of evidence in ecological risk assessmentso Toxicity testing
10
Why analyze porewater? (cont.)
An understanding of porewater in relation to
sediment properties provides for the following:
o Complete picture of the exposure to the
benthic aquatic environment;
o Comprehensive identification of contaminant
sources and sinks and their extent;
o Prediction of contaminant flux across the
sediment-water interface.11
Why analyze porewater? (cont.)
Evaluating concentrations in porewater is important to differentiate bioavailability of the contaminant from total concentration of the contaminant in the sediment.
This is possible only if porewater data truly reflects the in-situ conditions.
Many sampling and processing techniques do not address the possibility of geochemical transformation during porewater collection and extraction.
12
Porewater Collection
Collection and processing methods have the potential to cause geochemical changes to the porewater, primarily through oxidation.
This oxidation can lead to biased results that do not accurately represent the natural conditions.
Results can be biased to indicate both higher and lower concentrations compared to in-situ conditions.
What does this mean? The collection and processing technique selected should
be able to produce the most “realistic” data possible
14
Case Studies
Ubatuba Bay, Brazil, River Study Tennessee Valley Authority Kingston Ash Recovery Project
15
Ubatuba Bay, Brazil, River Study
Aim of study to present results of chemical analysis of ammonium ions from porewater extracted in oxygen-free environment
Sediment samples collected from four river estuaries on Ubatuba Bay in southeast Brazil
Historically, rivers have received discharges of raw sewage 16
Ubatuba Bay, Brazil, River Study (cont.)
Six samples collected from each location and split into two groups
One sample group processed in oxygen-free environment and other sample group exposed to the atmosphere
17
Tennessee Valley Authority Kingston Ash Recovery Project (TVA KRP)
Large release of fly ash spilled from containment area at the Kingston, TN, fossil plant in December 2008.
Approximately 5.4 million cubic yards of ash released from containment area with the majority discharging into the Emory River.
Two high flow storm events shortly after release
19
December 22, 2008
TVA KRP
In addition to the chemical constituents in fly ash (primarily metals – As, Se), this release also had the ecological impacts of large deposits of ash on the bottom of the river
Fly ash removed from the Emory River by hydraulic and mechanical dredging
Extensive sampling and monitoring program executed throughout the life of the project (ongoing)
20
TVA KRP – Porewater Sampling
Due to the nature of the project, multiple organizations are involved
Porewater samples have been collected by TVA and third-party researchers
Sampling occurred over multiple years at same general locations
Multiple porewater sampling methodologies have been implemented
21
As Sequential Extraction Procedure
23
SEP Fraction
Water Soluble Ion Exchangeable Carbonate Bound Fe/Mn Oxide Bound
Arse
nic
(mg/
kg)
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
ref 180d 600d ref 180d 600d ref 180d 600d ref 180d 600d
Days post spill (d)
mg/kg
TVA KRP - Summary
PW vs Total As concentrations between the collection methods suggest aerobic technique results in biased (high) data
Sediments included in TVA study have little to no sulfides
SEP data and previously published literature suggest Fe oxide is binding potentially bioavailable As.
Exposure to atmosphere during processing releases As to the porewater
24
Summary
If porewater sample collection is planned, proper
collection and processing methods are essential.
The documented effects of oxidation of porewater
during collection drives the need for collection and
processing of porewater in oxygen-free environment.
Improper sample collection can lead to biased data
not reflective of in-situ conditions.
Evaluating in-situ conditions needed to assess
bioavailability of contaminants.25
Contact
Environmental Standards, Inc.“Setting the Standards for Innovative Environmental Solutions”
Headquarters 1140 Valley Forge Road | PO Box 810 | Valley Forge, PA 19482 | 610.935.5577Virginia 1208 East Market Street | Charlottesville, VA 22902 | 434.293.4039
Tennessee 8331 East Walker Springs Lane, Suite 402 | Knoxville, TN 37923 | 865.376.7590Texas 11200 Richmond Avenue, Suite 350 | Houston, TX 77082 | 281.752.9782
Web www.envstd.com | E-mail [email protected]
27