Portable Evaporative Air Cooler OWNER’S MANUAL Read and save these instructions before use Ideal for Indoor & Outdoor Use 0 3 2 1 ON COOL SPEED SWING ON OFF OFF Model: CO60PM Power rating: 220 Watts Voltage rating: 220 Volt AC, 50Hz Made in P.R.C.

Upload: truongnga

Post on 06-Mar-2018

221 views

Category:

Documents


2 download

TRANSCRIPT

Portable Evaporative Air Cooler

OWNER’S MANUALRead and save these instructions before use

Ideal for Indoor & Outdoor Use

0 3

21ON

COOLSPEED

SWING

ON

OFF

OFF

Model: CO60PM

Power rating: 220 WattsVoltage rating: 220 Volt AC, 50Hz

Made in P.R.C.

QUICK START GUIDE

Fill with water and plug into standardpower outlet.

Place near open door or window.(When used in Indoors)

Note : Please make sure that the power outlet isset to correct settings as per product specifications.

Note : Evaporative Air Coolers work on evaporativecooling mechanism which requires cross ventillation.

Turn ON and enjoy the cooling breeze.

Note: Start with LOW speed and gradually increaseto higher speed for optimum cooling performance.

SECTION PAGE

1. THANK YOU .........................................................................................................2. USER TIPS ...........................................................................................................3. SAFETY RULES ...................................................................................................4. PARTS DESCRIPTION .........................................................................................5. USE & OPERATION .............................................................................................

Control Panel ....................................................................................................Function Buttons ...............................................................................................

6. CLEANING & MAINTENANCE .............................................................................7. TROUBLESHOOTING GUIDE .............................................................................8. TECHNICAL SPECIFICATIONS ...........................................................................9. ELECTRICAL WIRING DIAGRAM ........................................................................

2357888

Fill Water .......................................................................................................... 1011131415

INDEX

1

Read all instructions carefully before setting up and operating the unit, and please keep this instruction manual for future reference. This manual is designed to provide you with important information needed to setup, operate, maintain, and troubleshoot your cooler. Failure to follow these instructions may damage and/or impair its operation and void the warranty.

THANK YOU!

THANK YOU!

2

Congratulations on your purchase of this versatile Honeywell Evaporative Air Cooler. For optimum cooling performance from your unit, fill the water tank with water & ice (if available) to increase itscooling power.

COOLER LOCATION (IMPORTANT TO READ)(When used in Indoors)

Place the cooler in front of an open door or window. Ensure thatthere is adequate cross - ventillation in the room by leaving adoor or window open opposite from the cooler.Following these rules will ensure your cooler will work aseffectively as possible.

COOL ~ EFFICIENT ~ NATURAL

3

Pump

Water

Honeycomb Cooling Media

Evaporative Air Cooling Mechanism

Warm and

dry air

Cold and

humid air

Evaporative air cooling is the natural way of cooling, similar to a breeze blowing across a lake. This breeze drops the temperature and has a relaxing cooling effect.

The evaporative air cooler cools the air by means of the evaporation of water. When water evaporates into the air, the result is a mixture of air and water molecules. This chemical change requires heat which is taken from the water molecules, resulting in cooler air propelled from the unit.

USER TIPS

NOTE

4

USER TIPS

OFF

COOL

ON OFF

SWING

ON0 321

OFF

COOL

ON OFF

SWING

ON0 321

When the product is used for the first time the Honeycomb cooling media will have an odour which will dissipate in a weekor so of initial use.

The recommended maximum relative humidity level is 60% orless, which allows a noticeable temperature decrease. Thetemperature decrease will be greater in drier climates becausehigher evaporation occurs when the humidity is low.

The evaporative air cooler should not be used in enclosedspaces. It must be kept level and there must be water in thewater tank. The room should have doors and windows openedto allow free air flow. The evaporative air cooler works bestwhen placed near an open window, so that outside air is drawninto the evaporative air cooler, the air circulates in the room,then exits via the door. The maximum cooling effect is feltwhen a person is in the flow of air coming out of the evaporativeair cooler.

The evaporative air cooler can also be used to humidify dry airduring cool weather. To be used for humidification thewindows and doors should be closed to allow the humidifiedair to accumulate. The evaporative air cooler is not an airconditioner as it does not use a compressor or refrigerant gas.It should not be expected to cool as efficiently as a refrigeratedair conditioner.

READ AND SAVE THESE INSTRUCTIONS:

SAFETY RULES

220 Volt AC 50Hz

SHOCK HAZARD

WATER LEVEL INDICATOR

5

MAX

MIN

OFF

COOL

ON OFF

SWING

ON0 3 21

When using electrical appliances, basic safety precautions should always be followed:

••

Your cooler runs on 220 Volts, 50 Hz current. Check thehousehold voltage to ensure it matches the appliance's ratespecification.Before operating the product remove it from its packagingand check it is in good condition.DO NOT operate any product with a damaged cord or plug.We recommend not using an extension cord with thisappliance.DO NOT run power cord under carpeting, or cover it withrugs or runners. Keep the cord away from areas where itmay be tripped over.Always unplug the product before refilling the water tank.Always unplug the appliance from the power source beforecleaning, servicing or relocating the unit."Remove the power cord from the electrical receptacle bygrasping and pulling on the power cord plug-end only, neverpull the cord.DO NOT use the product in areas where gasoline, paint orother flammable goods and objects are stored.When using the ''COOL'' setting, please check the water tankto ensure it is full. Operation of this unit on the ''COOL'' settingwith an empty tank may result in damage to the water pump.

OFF

COOL

ON OFF

SWING

ON

01

2 3

Water / Ice compartment

SAFETY RULES

FLOOR LEVEL

6

•••

••

DO NOT attempt to repair or adjust any electrical or mechanicalfunctions of the cooler, as this may void the warranty.DO NOT cover the air inlet or outlet on the appliance as this may cause motor damage.DO NOT insert or allow objects to enter any ventilation orexhaust opening as this may damage the product and couldcause an electrical shock or fire.DO NOT operate with the Honeycomb media removed as thiswill overload and damage the motor.DO NOT leave the appliance operating unattended for anyextended period of time.DO NOT let children play with this appliance, packaging orplastic bags.If the unit is damaged or it malfunctions, do not continue tooperate it. Refer to the troubleshooting section and /or pleaseseek professional advice.Place the unit on a level floor.This product is not intended for use in wet or damp locations.Never locate the product where it may fall into a bathtub orother water container. DO NOT use in bathrooms.When the unit is not in use always store in a dry area.This appliance is not intended for use by persons (includingchildren or elderly) with reduced physical, sensory or mentalcapabilities, or lack of experience and knowledge, unless theyhave been given supervision or instruction concerning use ofthe appliance by a person responsible for their safety.Always grip the side handles to move the unit.

7

PARTS DESCRIPTION

OFF

COOL

ON OFF

SWING

ON0 3 21

1

2

9

8

3

10

11

14

12

13 4

5

6

7

1 Water / Ice Inlet2 Handle3 Left Honeycomb Panel4 Lever for Horizontal Louvers5 Water Tank6 Castors Wheels7 Horizontal Louvers

8 Water Level Indicator9 Control Panel10 Right Honeycomb Panel11 Continuous Water Inlet12 Water Drain Plug13 Backside Honeycomb Panel14 Power Cord & Plug

CONTROL PANEL

COOL SPEED SWING

OFF ON OFF ON0 32

1

NOTE:

Speed control may be marked as High / Med / Low in certain units.

USE & OPERATION

8

CONTROL KNOBS

SPEED / ON - OFF

COOL

OFF ON

SWING

OFF ON

SPEED

0 32

1

Connect to the power supply and turn the Speed knob. The fanwill start. Change the speed from 1 for Low to 2 for Medium to3 High. To switch OFF the unit turn the Speed know to "0".

COOLTo begin cooling the desired area press the ''COOL'' button. The indicator light will come on and the water pump will operate. You can feel the cooler air after the Honeycomb media is completely wet.

SWINGPress the ''SWING'' button. The indicator light will come on and the louvers will begin to move from right to left automatically. Manually adjust the horizontal louvers to change vertical airflow.

HORIZONTAL LOUVERS Manually adjust the horizontal louvers to change vertical airflow.

9

USE & OPERATION

Hose Connector

USE & OPERATION

INSTALLING HOSE ADAPTER

Manual operation

10

NOTE : Continuous water supply connection is optional, and may not be provided with all models.Connect the garden hose Connector and turn on the water.Verify water tight connections by visually examining boththe float/hose connections.

Water can be filled into the air cooler by:Continuous water supplyWith the help of garden hose connected to the hose connector on the unit, water will refill inside the tank on turning on the water tap.

Open the Water fill door located at the top of the unit (when facing front) & fill water up to the maximum tank level. Water level display is located on the front of the unit. Refill the water tank when water level is low. Do not fill water above the Max water level mark. Check water level in the tank before running the ''COOL'' function. Please be sure water in the tank is always above minimum water level mark. Running the unit with inadequate water may cause pump failure. If ice is available you may add ice in the top compartment to enhance the cooling performance.

As soon as the water inside the tank reaches the maximum level, the float valve inside the water tank will stop the in-flow of in the water tank.Due to the float valve and continuous supply of water. The water tank in this model will never be empty and will refill on its own as soon as the float wall goes below the desired level of maximum water inside the tank.

WARNING

CLEANING & DRAINING THE WATER TANK

••

••

11

Turn the power "off" and disconnect the unit from power supply.Move the unit to a location where it can be drained and remove the drainagetube/cap (see parts description on page 7).Once the tank is empty, refill with clean water and drain it again. This should be repeated weekly to maintain the integrity of the unit and to remove particles filtered from the air.Install the clean water tank to its original position and fill clean water inside the tank.

CLEANING & MAINTENANCE

Before cleaning the unit, switch it to the ''off'' position and remove the plug from the power socket.To clean the outside, use a damp cloth to remove dirt and dust.Never use corrosive elements or any chemicals to clean this product.When the product is not in use, store the unit in a dry place out of direct sunlight.

CLEANING & MAINTENANCE

MAINTAINING AND CHANGING THE HONEYCOMB

••

12

This unit is supplied with three (3) Honeycomb Cooling Media's located on the back &two sides. The removal procedure for all the media's is same as explained above.

NOTE:

Hand ScrewHand Screw

Honeycomb Holder

Side PanelFig.1

The appliance is supplied with Honeycomb cooling media.The cleaning frequency for the Honeycomb media depends on local air and waterconditions. In areas where the mineral content of water is high, mineral depositsmay build up on the honeycomb cooling media and restrict air flow. Draining thewater reservoir and refilling with fresh water at least once a week will help reduce mineral deposits. If mineral deposits remain on the Honeycomb media, the media should be removed and washed under fresh water. The media should be cleaned every two months or sooner, depending on your needs.Do not run the unit in COOL mode with stale water in the tank. It is recommendedto empty the tank and refill it with fresh water if the water has been standing in the tank for an extended period of time.For best results, allow the honeycomb cooling media to dry after each use by turning off the cool function 15 minutes before turning the unit off.To change the Honeycomb, remove the hand screws which hold the side panel(Refer Fig.1). Remove the Honeycomb holder and replace the Honeycomb.Refix theHoneycomb holder and screw back the panel to the unit.

TROUBLESHOOTING GUIDE

No discharge of air Cord is not plugged in. Make sure power cord is pluggedin and the supply switch in ON.

Power is not on.

Not Cooling / Unit ismaking noise

Pump is not turned ON. Turn on COOL function fromcontrol panel.

Low or no water in tank,when COOL is selected.

Refill water tank.

Odour omission New Unit.

Old Unit.

Damaged Pump orCalciumdeposits on blower.

Contact service centre.

PROBLEM POSSIBLE CAUSE SOLUTION

Try to turn the unit ON by changing the operation settings of manual knobs on the control panel.

When the unit is used for thefirst time, the Honeycomb cooling media will have an odour, which will dissipate within a week of initial use.

There may be an algae issue,Replace the honeycomb cooling media. Contact service centre.

13

MODEL NO. CO60PM

220V50Hz

200 Watts60 Litre

Honeycomb700 (L) x 466 (W) x 1017 (H)

20 Kg

VoltageFrequencyWattageWater Tank CapacityCooling MediaProduct DimensionNet Weight

TECHNICAL SPECIFICATIONS

14

ELECTRICAL WIRING DIAGRAM

15

© 2012 AirTek International Corporation LimitedThe Honeywell Trademark is used under license fromHoneywell International Inc.Honeywell International Inc. makes no representation or warranties with respect to this product.Manufactured by AirTek International Corporation Limited.

: