Positron Insulator Testers for High Voltage Live Line Testing Benefits Detects the following types of problems Critical failure can cause long term damages as well as equipment and financial loses Live-line work requires that the insulators be in good condition for lineman safety Outages due to insulator failure are costly Surface contamination Captive moisture Punctured insulators Carbon tracking Leaking insulators Allows early detection of leaking insulators Provides assessment of rate of degradation for future reference and analysis Includes insulator counting and location coordination No direct electrical contact therefore danger is minimized Single button operation makes it easy to use Allows for the testing of all types and sizes of insulators Enhanced operator safety Why is insulator testing so important?

Upload: phamque

Post on 07-Dec-2018

249 views

Category:

Documents


2 download

TRANSCRIPT

Page 1: Positron Insulator Testers for High Voltage Live Line Testing · The Positron Insulator Testers are revolutionary, simple to use lightweight tools that record defects and dangerous

Positron Insulator Testers for High Voltage Live Line Testing

Benefits

Detects the following types of problems

• Criticalfailurecancauselongtermdamagesaswellasequipmentandfinancialloses

• Live-lineworkrequiresthattheinsulatorsbeingoodconditionforlinemansafety

• Outagesduetoinsulatorfailurearecostly

• Surfacecontamination

• Captivemoisture

• Puncturedinsulators

• Carbontracking

• Leakinginsulators

• Allowsearlydetectionofleakinginsulators• Providesassessmentofrateofdegradationforfuturereferenceandanalysis

• Includesinsulatorcountingandlocationcoordination

• Nodirectelectricalcontactthereforedangerisminimized

• Singlebuttonoperationmakesiteasytouse

• Allowsforthetestingofalltypesandsizesofinsulators

• Enhancedoperatorsafety

Why is insulator testing so important?

Page 2: Positron Insulator Testers for High Voltage Live Line Testing · The Positron Insulator Testers are revolutionary, simple to use lightweight tools that record defects and dangerous

ThePositron Insulator Testers are revolutionary, simple to use lightweight tools that record defects anddangerousconditionsonenergizedsuspensioninsulators,stationposts,bushingsandlightningarresters.Theymeasuretheelectricfieldalongthe insulators,recordtheelectricalfieldandallconductive insulatordefects. They can be used on all types of insulators (Porcelain, Composite, Glass* for contaminationassessment,etc.)andaresafe,simpleandaccurate.

Theoperationalintegrityofhighvoltageinsulatorsisapriority,particularlywhenyouconsiderthatadamaged,electricallydeficient insulatorcan leadtosystemfailure,serious injury,or lossof life.Positron’s InsulatorTesters are amajor advance in insulatormaintenance, they allow for the safe and reliable evaluation ofhighvoltageinsulators.Simplyslidethetestersledalongtheinsulatororinsulatorstringandtheresultsareautomaticallyprocessedandavailable.

Electric Field MethodologyPositron’sInsulatorTesterallowsforthediagnosticevaluationofbothPorcelainandCompositeinsulators.

• The Insulator Tester measures the AC electric field surroundingporcelainandcompositeinsulators

• Thefieldisproportionaltothevoltageacrossaninsulatoranddropsataconductivedefectlocation

• Theelectricfieldisreadandstoredoneachdiscorskirt

How it works(Stepstofollow)

1. Theoperatorpositionshimselfandpressesthepushbuttonontheprobeandthelogger(optional).

2. Thetesterisplacedonthestringafewinsulatorsbelowthegroundedend.

3. Thetesterisslidbacktothebeginningofthestringandkeptstation-aryforatleast10secondsuntilalongbeepingsoundisheard.

4. The tester isslid to the lineendof thestringandthenback to thestartingpoint.Thebuzzersoundseachtimeareadingistakenateachinsulator.

5. Thetester isremovedfromthestringbymakingsureacontinuoussoundisheard(indicatingasuccessfulscan)andthenthepushbut-tonispressedtostorethedata.

Safe, Simple and Accurate

TheimagebelowdepictstheuseofanInsulatorTesteronaVString

ElectricfieldmethodologyconfirmsthataleakingdiscisdetectedonaPorcelainstring

Microprocessor Based TechnologyTestresultsareacquiredandstoredbyanonboardmicroprocessor allowing readings to then beuploaded to any PC-based laptop for graphicaldisplay,analysisandlongtermcomparisons.Compatible with Standard Field EquipmentAll units include a universal hot stick mountingbracketcompatiblewithstandardindustryhotsticks.

Tests Porcelain, Composite, Glass, Station Post and other InsulatorsTesterunitsallowforthetestingofalltypesandsizesofinsulators.

Features

Lightweight and DurableThe Positron Insulator Testers are lightweight,durableandengineeredtowithstandfieldconditions.Theycomesecureinaruggedizedcarryingcaseforconvenientportabilityandfielddurability.

Optional Data Logger (Mini Laptop)The data logger is used to identify each insulatorstring to be tested, eliminating the need to takeon-sitehandwrittennoteswhile testing.The loggerstores the identification of each insulator stringtested.

Page2of6

*forcontaminationassessment

Page 3: Positron Insulator Testers for High Voltage Live Line Testing · The Positron Insulator Testers are revolutionary, simple to use lightweight tools that record defects and dangerous

Composite Insulator Tester

DataPortRS-232-TheTesterunit’sdataportallowsuploadingofdatatoaPC-basedworkstationforgraphicaldisplay,analysisandstorage.ON/OFFPowerswitchlocatedundercover.

SinglebuttonoperationmakestheCompositeTestereasytouse.Theoperatorsimplyturnsontheunit,slidesthetesteralongtheinsulatorstring.Thereisnodirectelectricalcontactsodangerisminimizedonmarginalinsulators.

• UsedforPolymerorCompositeNCI(NonCeramicInsulators)• Sledmounted(customdesignsledavailable)• Bestforinsulatorsofmorethan10skirts• Capturesupto15,000readings• Rechargeablebattery• Adjustableskidfordifferentinsulatordiametersfrom4.3”to6.7”(10.9to17cm)• AlsoavailablewithGO/NO-GOfeaturecapableofdeterminingifitissafefortransmissionpersonnelto

performworkonliveACtransmissionpowerlines

SledFieldProbe

Skid-Adjustableskidfordifferentinsulatordiameters

UniversalHotStickMountingBracket

MiniLaptop

BluetoothTransmitter(Transferringofdatatotheminilaptop)

OperationActivationButton

StatusLED

Page3of6

Page 4: Positron Insulator Testers for High Voltage Live Line Testing · The Positron Insulator Testers are revolutionary, simple to use lightweight tools that record defects and dangerous

UniversalHotStickMountingBracket

AlternateProbeAttachement

Porcelain Insulator Tester

DataPortRS-232-TheTesterunit’sdataportallowsuploadingofdatatoaPC-basedworkstationforgraphicaldisplay,analysisandstorage.ON/OFFPowerswitchlocatedundercover

SinglebuttonoperationmakesthePorcelainTesterveryeasytouse.Theoperatorsimplyturnsontheunit,slides the testeracross the insulatordiscs.There isnodirectelectrical contact sodanger isminimizedonmarginalinsulators.• UsedforPorcelainandGlass*insulators• Sledmounted(customdesignsledavailable)• Bestforinsulatorstringsof4bellsormore• Capturesupto15,000readings• Rechargeablebattery• Adjustableskidfordifferentinsulatordiametersfrom9”to13”(22.9to33cm)• Providesinstantstatusreportinganddangerconditions

Sled

FieldProbe

Skid-Adjustableskidfordifferentinsulatordiameters

OperationActivationButton

StatusLED

Page4of6

*forcontaminationassessment

Page 5: Positron Insulator Testers for High Voltage Live Line Testing · The Positron Insulator Testers are revolutionary, simple to use lightweight tools that record defects and dangerous

Universal Insulator Tester

TheUniversalTestercanbeusedforvariousshapesofinsulatorsandonlowervoltageapplications(from7kVto115kV).TheUniversalTesterusesanactuatorswitchinsteadofasled.

• Usedonalltypesofinsulators(Porcelain,GlassorComposite)• Idealforsubstationenvironments(conicalshapedinsulators,bushings,stationposts,lightning

arresters,etc)

UniversalHotStickMountingBracket

DataPortRS-232andON/OFFPowerswitchlocatedundercover

ActuatorSwitch

Graphicaloutputofadamageddisc(on#15)ofastringofPorcelainInsulators

GraphicaloutputofadamagedCompositeInsulator(Carbontrackingof8skirtslongfrom#43to#51)

OperationActivationButton

StatusLED

FieldProbe

Examples of Insulator Test Result Graphs

Page5of6

Page 6: Positron Insulator Testers for High Voltage Live Line Testing · The Positron Insulator Testers are revolutionary, simple to use lightweight tools that record defects and dangerous

Page6of6

PORCELAIN COMPOSITE UNIVERSAL Parameter Model #

3781301P/60-60Hz3781301P/50-50Hz

3782091C/60-60Hz3782091C/50-50Hz

3782651U/60-60Hz3782651U/50-50Hz

Maximumdiscs/skirtsperinsulatorstring

55discsperinsulatorstring

150skirtsperinsulatorstring

40testedpointsperinsulator(80readings)

Minimumdiscs/skirtsperinsulatorstring

4discsperinsulatorstring

10skirtsperinsulatorstring

3testedpointsperinsulator(6readings)

Maximumcoronaprotection

1millionVolts 1millionVolts 1millionVolts

Minimumelectricalfield 10kV/meter 10kV/meter 7kV/meterMaximummemorycapacity

300stringsofinsulatorsor15,000readings,whichevercomesfirst

300stringsofinsulatorsor15,000readings,whichevercomesfirst

300stringsofinsulatorsor15,000readings,whichevercomesfirst

Maximumscanningspeed 6discspersecond 5skirtspersecond(Max)0.5skirtspersecond(Min)

Manualscanning

Maximumtimebetweenuploadingofcumulativedata

12days 12days 12days

Maximumtimebetweenbatterycharges

12hours 12hours 10hours

Minimumtimeofbatteryrecharging

10hours(onenight) 10hours(onenight) 10hours(onenight)

Timetagupdateinterval 16seconds 16seconds 16secondsOperatingtemperaturerangefortheprobe

-22°Fto122°F(-30°Cto50°C)

-22°Fto122°F(-30°Cto50°C)

-22°Fto122°F(-30°Cto50°C)

Operatingtemperatureforthelogger

32°Fto122°F(0°Cto50°C)

32°Fto122°F(0°Cto50°C)

32°Fto122°F(0°Cto50°C)

Dimensions W:14”xH:19”xD:9”(35.5x48x23cm)

W:12”xH:11”xD:6”(30.5x28x15cm)

W:10.6”xH:4.7”xD:2“(27x12x5cm)

Weight(loggerexcluded) 3.5lbs(1.59kg) 2.4lbs(1.09kg) 1.76lbs(0.8kg)

Sizeofinsulator 9”to13”(23to33cm)

4.3“to6.7“(11to17cm)

Any

Calibration Calibratedatfactory,nosubsequentcalibrationrequired

Calibratedatfactory,nosubsequentcalibrationrequired

Calibratedatfactory,nosubsequentcalibrationrequired

Note:ApplicationonAClinesonly

Insulator Tester Specifications

Doc#: PID 103117

www.positronpower.comPositronInc.,5101Buchan,Suite220Montreal,Quebec,H4P2R9Canada•Tel:+1-514-345-2220

Salvatore CarbonaroDir.BusinessDevelopment&[email protected]