post frame light gauge application guide
TRANSCRIPT
POST FRAME LIGHT GAUGE
APPLICATION GUIDE
Lebanon, PA • 888.339.0059Bridgton, ME • 888.339.0059
Howe, IN • 866.562.3782www.everlastroofing.com
Table of Contents
Post Frame Light Guage
All information is © copyright Everlast Roofing, Inc. 2010
Post Frame Light Gauge
Post Frame Trim Light Gauge Trim LG 02 - LG 03 Application Guidelines Safety and Minimum Slope LG 04 Handling and Storage LG 05 Installation / Ventilation / Cutting LG 06 Coverage / Overlap/Screw / Nail Patterns LG 07 - LG 08
Post Frame Details Post Frame Ridge and Hip LG 09 Post Frame Rake & Corner LG 10 Post Frame Base Angle LG 11 Post Frame Fascia LG 12 Post Frame Gable LG 13 Post Frame J Channel LG 14 Post Frame Double Angle LG 15 Post Frame Sidewall LG 16 Post Frame Drip Cap LG 17 Post Frame Post Trim LG 18 Post Frame Endwall LG 19 Post Frame F & J Trim LG 20 Post Frame Inside Corner LG 21 Post Frame Overhead Door LG 22 Post Frame Track Cover LG 23 Post Frame Drip Edge LG 24 Post Frame Fascia & Soffit LG 25 Post Frame Formed Valley LG 26 Post Frame Notched Endwall LG 27
All information is © copyright Everlast Roofing, Inc. 2010
Purpose:
This application guide is intended to assist in the application of light gauge Everlast Roofing products on post frame structures. The details and illustrations in this manual may not be applicable to all building plans or field situations. It is the buyer's responsibility to verify all applicable code requirements, check all field measurements, and determine suitability of the material for the job.
Post Frame Light GuagePost Frame Light Gauge
LG-02
O
C
G
J
BI
M
KH
E
N
FD
A
A 29 Ga. 13” Univ. Ridge 10’6” TLURC1xx
˝4
F
4˝
31˝4/ 1
˝4/35/8˝
Jan. 07
F
E 29 Ga. Fascia Trim 10’2” TLFT4xx
˝3
4 1/
2˝1˝
7/8˝
D 29 Ga. Base Angle 10’2” TLBA3xx
1˝
1 3
/4˝
11/
2˝
F
C 29 Ga. Gable Trim 10’2” TLGT5xx
F
7/8˝
˝2
/5
1
1˝4 1/2˝
1˝
Coverage/Overlap and Screw/Nail Pattern of Everlast II™Everlast II™ Post Frame Trim
I 29 Ga. Drip Cap 10’2” TLDC9xx
F
1˝
˝83/
2
˝8/7
L
B 29 Ga. Rake & Corner 10’ 12’ 14’ 16’ TLRC2xxxx
F4 1/2˝
4 1/
2˝
7/8˝
1˝
1˝
C
P
E “F” 6.5” Trim10’2” TL6.5F60xx29 Ga. Drip Edge
F
4˝
3/4˝
4˝/3
1/˝2
G 29 Ga. Double Angle 10’2” TLDA7xx
F
˝2
/1
1
1˝
˝4
/3
1
H 29 Ga. Univ. Sidewall 10’2” TLUS8xx
F
1˝
2 5/
8˝
3 1/2˝ 7/8˝
F 29 Ga. “J” Channel 10’2” TLJC6xx
F
˝8
/3
2
˝1
7/8˝
I
P
L 29 Ga. “F” & “J” 10’2” TLFJ12xx
1˝7/8˝
9/16˝
˝2
3/8
1 ˝
F
K 29 Ga. Univ. Endwall 10’2” TLUE11xx
F
6˝
˝4
K 29 Ga. Notched Endwall EL42” TLNEEL32xx
F
5˝
˝1
˝6
Notched to fit panel profileF
J 29 Ga. Post Trim 10’2” TLPT10xxxx
3 1/2˝5 1/2˝
6˝7 1/4˝
˝/2
1 1
7 1/2˝7 3/4˝9 3/4˝ 11˝
P
˝8/1 4
1/2˝
4 1/8˝
F
1/2˝
C 29 Ga. AG4 Gable Trim 10’2” TLFS17xx
L 29 Ga. 11.25” Fascia & Soffit 10’2” TLFS17xx
4 3/4˝
˝1/
25
11 1/4˝
1˝˝8/5
4 3/4˝
˝2
M 29 Ga. Inside Corner 10’2” TLIC13xx
F
1˝
˝/87
4 1/2˝
2˝/14
1˝
F
O 29 Ga. Track Cover Cannonball FM 10’2” TLCT15xx
F1 3/4˝
1 3
/4˝
˝8
/3
1
58/˝
7˝
N 29 Ga. Overhead Door 10’2” 12’6” TLODT14xx
F
1 1/2˝
1˝
˝8
/7
˝9
P
All information is © copyright Everlast Roofing, Inc. 2010
O
C
G
J
BI
M
KH
E
N
FD
A
A 29 Ga. 13” Univ. Ridge 10’6” TLURC1xx
˝4
F
4˝
31˝4/ 1
˝4/35/8˝
Jan. 07
F
E 29 Ga. Fascia Trim 10’2” TLFT4xx
˝3
4 1/
2˝1˝
7/8˝
D 29 Ga. Base Angle 10’2” TLBA3xx
1˝
1 3
/4˝
11/
2˝
F
C 29 Ga. Gable Trim 10’2” TLGT5xx
F
7/8˝
˝2
/5
1
1˝4 1/2˝
1˝
Coverage/Overlap and Screw/Nail Pattern of Everlast II™Everlast II™ Post Frame Trim
I 29 Ga. Drip Cap 10’2” TLDC9xx
F
1˝
˝8
3/
2
˝8/7
L
B 29 Ga. Rake & Corner 10’ 12’ 14’ 16’ TLRC2xxxx
F4 1/2˝
4 1/
2˝
7/8˝
1˝
1˝
C
P
E “F” 6.5” Trim10’2” TL6.5F60xx29 Ga. Drip Edge
F
4˝
3/4˝
4˝/3
1/˝2
G 29 Ga. Double Angle 10’2” TLDA7xx
F
˝2
/1
1
1˝˝
4/
3
1
H 29 Ga. Univ. Sidewall 10’2” TLUS8xx
F
1˝
2 5/
8˝
3 1/2˝ 7/8˝
F 29 Ga. “J” Channel 10’2” TLJC6xx
F
˝8
/3
2
˝1
7/8˝
I
P
L 29 Ga. “F” & “J” 10’2” TLFJ12xx
1˝7/8˝
9/16˝
˝2
3/8
1 ˝
F
K 29 Ga. Univ. Endwall 10’2” TLUE11xx
F
6˝
˝4
K 29 Ga. Notched Endwall EL42” TLNEEL32xx
F
5˝
˝1
˝6
Notched to fit panel profileF
J 29 Ga. Post Trim 10’2” TLPT10xxxx
3 1/2˝5 1/2˝
6˝7 1/4˝
˝/2
1 1
7 1/2˝7 3/4˝9 3/4˝ 11˝
P
˝8/1 4
1/2˝
4 1/8˝
F
1/2˝
C 29 Ga. AG4 Gable Trim 10’2” TLFS17xx
L 29 Ga. 11.25” Fascia & Soffit 10’2” TLFS17xx
4 3/4˝
˝1/
25
11 1/4˝
1˝˝8/5
4 3/4˝
˝2
M 29 Ga. Inside Corner 10’2” TLIC13xx
F
1˝
˝/87
4 1/2˝
2˝/14
1˝
F
O 29 Ga. Track Cover Cannonball FM 10’2” TLCT15xx
F1 3/4˝
1 3
/4˝
˝8
/3
1
58/˝
7˝
N 29 Ga. Overhead Door 10’2” 12’6” TLODT14xx
F
1 1/2˝
1˝
˝8
/7
˝9
P
LG-03
Post Frame Trim
All information is © copyright Everlast Roofing, Inc. 2010
Application Guidelines
Safety:
Always work safely when installing metal products. Use extreme caution on a roof at all times, and wear gloves and safety glasses to avoid injury. Hearing protection should be used when power-cutting metal panels. Do not walk on panels until all fasteners are installed. Metal panels are slippery when wet, dusty, frosty or oily. Do not attempt to walk on a metal roof under these conditions. Always use OSHA recommended safety harness or equipment when working on a roof. Wear soft-soled shoes to improve traction and to minimize damage to the paint finish. Always be aware of your position on the roof relative to any roof openings, roof edges, co-workers, and penetrations. Installing metal panels on a windy day can be dangerous and should be avoided. Consult OSHA guidelines for more comprehensive safety requirements.
Minimum Slope:
Everlast Roofing light gauge products are designed to be installed on pitches of no less than 3:12. Please contact an Everlast sales representative for product recommendations on lower sloped roofs.
ALLOWABLE UNIFORM LIVE LOADS IN POUNDS PER SQUARE FOOT
Live Load based on L/180 deflection Wind Load (Stress)
Span (Feet) 2ʹ0ʺ 2ʹ6ʺ 3ʹ0ʺ 3ʹ6ʺ 4ʹ0ʺ 2ʹ0ʺ 2ʹ6ʺ 3ʹ0ʺ 3ʹ6ʺ 4ʹ0ʺ
29 Gauge (.015) 156 79 46 - - 207 105 61 - -
1. Maximum allowable loads are based upon a continuous three span sheet application.2. Calculated in accordace with the 1996 AISI Cold Formed Steel Design Manual.3. Maximum allowable loads for wind have been increased by 33%.4. Allowable deflection loads are limited by a maximum deflection ratio of L/180 of span.5. Everlast Roffing, Inc. reserves the right to change the specifications of its products without notice.
Post Frame Light GuagePost Frame Light Gauge
LG-04
All information is © copyright Everlast Roofing, Inc. 2010
Handling:
A. Do not lift panels from ends while flat. Lift the panels on edge when moving individual panels or when moving panels onto the roof.
B. Do not unload in a jerking or bouncing fashion. While unloading, the bundle must be handled at lift point, specified by Everlast Roofing, Inc. Panels greater than 25' long should be unloaded using spreader bar to prevent panels from bending.
C. Although the paint coating is tough, dragging panels across the surface of one another will almost certainly damage the finish. Improper handling of metal panels may cause scratches to the paint finish. ELR offers matching touch up paint in a variety of standard colors in the event of any scratches to the paint finish. Please note: touch up paint will not weather as well or at the same rate as the original coating or finish.
Storage:
A. If the material is not to be used immediately, it should be stored in a dry place. Moisture trapped between sheets may cause damage to the paint system. The paint system may become soft or water stains may appear which can detract from the appearance and affect the service life of the material. To avoid problems store the materials in a well-ventilated dry area. Stack the materials in an incline position. DO NOT USE PLASTIC TO COVER MATERIALS. THIS CAN CAUSE SWEATING OR CONDENSATION!
Post Frame Light GuagePost Frame Light Gauge
LG-05
All information is © copyright Everlast Roofing, Inc. 2010
Installation Recommendations:
- Panels can be installed over open purlins. See load chart for spacing- Panels should be installed against any prevailing wind- Panels should be installed square, plumb and properly aligned to one another- Galvanized and galvalume panels should remain void of any condensation containing copper, lead or uncoated steel materials- In situations where an endlap of a panel is required, be certain to overlap upper panel a minimum of 8” over lower panel and apply sealant and butyl lap tape uniformly between the two panels.
Ventilation/Insulation:
Proper design and installation of vapor barriers and ventilation systems are important to prevent condensation and the resulting problems of moisture damage and loss of insulation efficiency. Condensation occurs when moisture-laden air comes in contact with a surface temperature equal to or below the dew point of the air. This phenomenon creates problems that are not unique to metal buildings; these problems are common to all types of construction. In addition to providing resistance to heat transfer, insulation can also protect against condensation forming on cold surfaces, either inside the building or within the wall/roof/system cavity. The arrangement of the building’s insulation system and vapor retarder is the responsibility of the building designer. These are some basic guides to help control condensation.
A. The insulation should have a vapor retarder face on the “warm” side of the insulation. For most buildings, this means that the vapor retarder is on the inside surface (toward the building’s interior).B. The thickness of the insulation must be designed to maintain temperature of the vapor retarder above the interior dew point, using the worst-case expected outside temperature.C. All perimeter conditions, seams, and penetrations of the vapor retarder must be adequately sealed in order to provide a continuous membrane to resist the passage of water vapor.D. Building ventilation, whether by gravity ridge vent, power-operated fans, or other means, contributes significantly to reduced condensation. The movement of air to the outside of the building reduces the interior level of vapor pressure. On the buildings that have an attic space or are being retrofitted with metal roofing systems, vents should be placed at both the eave and peak of the roof in order to prevent a buildup of moisture (humidity) in the attic space. Contact your local building code official or an engineer on proper ventilation practices for you area.
Cutting:
Everlast recommends the use of tin snips or a "nibbler" type electric tool to field cutting metal panels. Cutting metal panels may create metal shavings.
A. These shavings and/or chips must be removed immediately from the panel surface. Failure to remove such shavings or chips may cause staining and/or rust on the panel.. Any such surface damage will void the warranty.B. For your protection goggles should be worn when cutting metal panels and flashing.
* This same principle applies when driving steel fasteners (see pages LG07 & LG08)
Post Frame Light GuagePost Frame Light Gauge
LG-06
All information is © copyright Everlast Roofing, Inc. 2010
OVERLAP
Roof Structure
Siphon GrooveWoodscrew
SCREW PATTERN NAIL PATTERN
*Note - minimum of 1" fastener penetration is recommended
COVERAGE
Coverage/Overlap and Screw/Nail Pattern of Everlast II™Coverage/Overlap and Screw/Nail Pattern of Everlast II™
LG-07
All information is © copyright Everlast Roofing, Inc. 2010
SCREW PATTERN NAIL PATTERN
OVERLAP
Siphon Groove
Coverage/Overlap and Screw/Nail Pattern of Everdrain™
COVERAGE
Roof Structure
Wood Screw
Coverage/Overlap and Screw/Nail Pattern of Everdrain™
LG-08
All information is © copyright Everlast Roofing, Inc. 2010
Panel
Ridge CapFastener
Ridge Vent
Vapor Barrier
Profile01 Universal Ridge
TLURC1xx
Post Frame Vented RidgePost Frame Universal Ridge
LG-09
All information is © copyright Everlast Roofing, Inc. 2010
Profile02 Rake & Corner
TLRC2xxxx
Panel
Caulk
Caulk
Fastener
Girt
Post
Fastener
Post Frame Rake & Corner
LG-10
All information is © copyright Everlast Roofing, Inc. 2010
Profile03 Base Angle
TLBA3xx
1˝
SkirtBoard
Panel
Inside Closure
Fastener
Caulk
Post Frame Base Angle
LG-11
All information is © copyright Everlast Roofing, Inc. 2010
Profile04 Fascia Trim
TLFT4xx
Panel
Caulk
Caulk
Fastener
RoofFastener
Fastener
Outside Closure
Caulk
PanelTop Plate
Post
Roof Truss
Inside Closure
Caulk
Purlin
Post Frame Fascia Trim
LG-12
All information is © copyright Everlast Roofing, Inc. 2010
Profile05 Gable Trim
TLGT5xx
Panel
Panel
Caulk
Outside Closure
Purlin
End Rafter
Caulk
Post Frame Gable Trim
LG-13
All information is © copyright Everlast Roofing, Inc. 2010
06 “J” Channel
TLJC6xx
Profile
Girt
FastenerPanel
DoorDoor Jamb
Door Stop
Caulk
'J' Channel
Post Frame “J” Channel
LG-14
All information is © copyright Everlast Roofing, Inc. 2010
07 Double Angle
TLDA7xx
Profile
Panel
Caulk
Inside Closure
Butyl Tape Caulk
Fastener
Fastener
Panel
Girt
Outside Closure
Post Frame Double Angle
LG-15
All information is © copyright Everlast Roofing, Inc. 2010
08 Universal Sidewall
TLUS8xx
Profile
Panel
Girt
Sloping Rafter
Purlin
Panel
Fastener
Inside Closure
Fastener
Caulk
Butyl Tape
Post Frame Universal Sidewall
LG-16
All information is © copyright Everlast Roofing, Inc. 2010
09 Drip Cap
TLDC9xx
Profile
Panel
Window Unit
Inside Closure
Fastener
Caulk
Post Frame Drip Cap
LG-17
All information is © copyright Everlast Roofing, Inc. 2010
Profile10 Post Trim
TLPT10xxxx
Girt
Fastener
Panel
DoorDoor Jamb
Door Stop
Fastener
Caulk
'J' Channel
Post Frame Post Trim
LG-18
All information is © copyright Everlast Roofing, Inc. 2010
11 Universal Endwall
TLUE11xx
Profile
Post Frame Universal Endwall
Panel
Fastener
Fastener
OutsideClosure
Purlin
Butyl Tape
Inside Closure
Girt
Butyl Tape
LG-19
All information is © copyright Everlast Roofing, Inc. 2010
12 “F” & “J” Trim
TLFJ12xx
Profile
Post Frame “F” & “J” Trim
Panel
Fastener
InsideClosure
Wall Structure
Panel
Fastener
Caulk
Soffit
Facia Board
Post Trim
LG-20
All information is © copyright Everlast Roofing, Inc. 2010
Profile13 Inside Corner
TLIC13xx
Girt
Girt
Post
Caulk
Caulk
Fastener
Fastener
Post Frame Inside Corner
LG-21
All information is © copyright Everlast Roofing, Inc. 2010
Profile14 Overhead Door
TLODT14xx
Door Stops
Man Door
Panel
Door Header
OverheadDoor
Post Frame Overhead Door
LG-22
All information is © copyright Everlast Roofing, Inc. 2010
Profile15 Track Cover Cannonball FM
TLCT15xx
Post Frame Track Cover Cannonball FM
Girt
Fastener
Panel
Caulk
LG-23
All information is © copyright Everlast Roofing, Inc. 2010
Profile60 Drip Edge
TL6.5F60xx
Facia BoardCaulk
Drip Edge
Inside Closure
EL Panel
Fastener
Soffit
Butyl Tape
Post Trim
Post Frame Drip Edge
LG-24
All information is © copyright Everlast Roofing, Inc. 2010
Profile17 Fascia & Soffit
TLFS17xx
Facia Board
Panel
Fastener
Panel
Girt
SoffitFastener
Fastener
Inside Closure
Butyl Tape
Post Frame Fascia & Soffit
LG-25
All information is © copyright Everlast Roofing, Inc. 2010
Profile19 Formed Valley
TLFV19xx
Post Frame Formed Valley
Panel
Vapor Barrier
Formed ValleySolid Roof Structure
Valley Closure
LG-26
All information is © copyright Everlast Roofing, Inc. 2010
Profile32 Notched Endwall EL
TLNEEL32xx
Post Frame Notched Endwall EL
Panel
Purlin
Butyl TapeTop & Bottom
of Closure
Caulk
Inside Closure
Fastener
Notched to fit panel profile
Outside Closure
Girt
LG-27
Notes
All information is © copyright Everlast Roofing, Inc. 2010
10 Enterprise CourtLebanon, PA 17042
Office: 888-339-0059Fax: 717-270-6569
7180 N 050 EHowe, IN 46746
Office: 866-562-3782Fax: 260-562-3738
P.O. Box 278, 81 South High St.Bridgton, ME 04009-0278
Office: 888-339-0059Fax: 207-647-5599