POST FRAME LIGHT GAUGE

APPLICATION GUIDE

Lebanon, PA • 888.339.0059Bridgton, ME • 888.339.0059

Howe, IN • 866.562.3782www.everlastroofing.com

Page 2: post frame light gauge application guide
Page 3: post frame light gauge application guide

Table of Contents

Post Frame Light Guage

All information is © copyright Everlast Roofing, Inc. 2010

Post Frame Light Gauge

Post Frame Trim Light Gauge Trim LG 02 - LG 03 Application Guidelines Safety and Minimum Slope LG 04 Handling and Storage LG 05 Installation / Ventilation / Cutting LG 06 Coverage / Overlap/Screw / Nail Patterns LG 07 - LG 08

Post Frame Details Post Frame Ridge and Hip LG 09 Post Frame Rake & Corner LG 10 Post Frame Base Angle LG 11 Post Frame Fascia LG 12 Post Frame Gable LG 13 Post Frame J Channel LG 14 Post Frame Double Angle LG 15 Post Frame Sidewall LG 16 Post Frame Drip Cap LG 17 Post Frame Post Trim LG 18 Post Frame Endwall LG 19 Post Frame F & J Trim LG 20 Post Frame Inside Corner LG 21 Post Frame Overhead Door LG 22 Post Frame Track Cover LG 23 Post Frame Drip Edge LG 24 Post Frame Fascia & Soffit LG 25 Post Frame Formed Valley LG 26 Post Frame Notched Endwall LG 27

Page 4: post frame light gauge application guide

All information is © copyright Everlast Roofing, Inc. 2010

Purpose:

This application guide is intended to assist in the application of light gauge Everlast Roofing products on post frame structures. The details and illustrations in this manual may not be applicable to all building plans or field situations. It is the buyer's responsibility to verify all applicable code requirements, check all field measurements, and determine suitability of the material for the job.

Post Frame Light GuagePost Frame Light Gauge

LG-02

O

C

G

J

BI

M

KH

E

N

FD

A

A 29 Ga. 13” Univ. Ridge 10’6” TLURC1xx

˝4

F

31˝4/ 1

˝4/35/8˝

Jan. 07

F

E 29 Ga. Fascia Trim 10’2” TLFT4xx

˝3

4 1/

2˝1˝

7/8˝

D 29 Ga. Base Angle 10’2” TLBA3xx

1 3

/4˝

11/

F

C 29 Ga. Gable Trim 10’2” TLGT5xx

F

7/8˝

˝2

/5

1

1˝4 1/2˝

Coverage/Overlap and Screw/Nail Pattern of Everlast II™Everlast II™ Post Frame Trim

I 29 Ga. Drip Cap 10’2” TLDC9xx

F

˝83/

2

˝8/7

L

B 29 Ga. Rake & Corner 10’ 12’ 14’ 16’ TLRC2xxxx

F4 1/2˝

4 1/

7/8˝

C

P

E “F” 6.5” Trim10’2” TL6.5F60xx29 Ga. Drip Edge

F

3/4˝

4˝/3

1/˝2

G 29 Ga. Double Angle 10’2” TLDA7xx

F

˝2

/1

1

˝4

/3

1

H 29 Ga. Univ. Sidewall 10’2” TLUS8xx

F

2 5/

3 1/2˝ 7/8˝

F 29 Ga. “J” Channel 10’2” TLJC6xx

F

˝8

/3

2

˝1

7/8˝

I

P

L 29 Ga. “F” & “J” 10’2” TLFJ12xx

1˝7/8˝

9/16˝

˝2

3/8

1 ˝

F

K 29 Ga. Univ. Endwall 10’2” TLUE11xx

F

˝4

K 29 Ga. Notched Endwall EL42” TLNEEL32xx

F

˝1

˝6

Notched to fit panel profileF

J 29 Ga. Post Trim 10’2” TLPT10xxxx

3 1/2˝5 1/2˝

6˝7 1/4˝

˝/2

1 1

7 1/2˝7 3/4˝9 3/4˝ 11˝

P

˝8/1 4

1/2˝

4 1/8˝

F

1/2˝

C 29 Ga. AG4 Gable Trim 10’2” TLFS17xx

L 29 Ga. 11.25” Fascia & Soffit 10’2” TLFS17xx

4 3/4˝

˝1/

25

11 1/4˝

1˝˝8/5

4 3/4˝

˝2

M 29 Ga. Inside Corner 10’2” TLIC13xx

F

˝/87

4 1/2˝

2˝/14

F

O 29 Ga. Track Cover Cannonball FM 10’2” TLCT15xx

F1 3/4˝

1 3

/4˝

˝8

/3

1

58/˝

N 29 Ga. Overhead Door 10’2” 12’6” TLODT14xx

F

1 1/2˝

˝8

/7

˝9

P

Page 5: post frame light gauge application guide

All information is © copyright Everlast Roofing, Inc. 2010

O

C

G

J

BI

M

KH

E

N

FD

A

A 29 Ga. 13” Univ. Ridge 10’6” TLURC1xx

˝4

F

31˝4/ 1

˝4/35/8˝

Jan. 07

F

E 29 Ga. Fascia Trim 10’2” TLFT4xx

˝3

4 1/

2˝1˝

7/8˝

D 29 Ga. Base Angle 10’2” TLBA3xx

1 3

/4˝

11/

F

C 29 Ga. Gable Trim 10’2” TLGT5xx

F

7/8˝

˝2

/5

1

1˝4 1/2˝

Coverage/Overlap and Screw/Nail Pattern of Everlast II™Everlast II™ Post Frame Trim

I 29 Ga. Drip Cap 10’2” TLDC9xx

F

˝8

3/

2

˝8/7

L

B 29 Ga. Rake & Corner 10’ 12’ 14’ 16’ TLRC2xxxx

F4 1/2˝

4 1/

7/8˝

C

P

E “F” 6.5” Trim10’2” TL6.5F60xx29 Ga. Drip Edge

F

3/4˝

4˝/3

1/˝2

G 29 Ga. Double Angle 10’2” TLDA7xx

F

˝2

/1

1

1˝˝

4/

3

1

H 29 Ga. Univ. Sidewall 10’2” TLUS8xx

F

2 5/

3 1/2˝ 7/8˝

F 29 Ga. “J” Channel 10’2” TLJC6xx

F

˝8

/3

2

˝1

7/8˝

I

P

L 29 Ga. “F” & “J” 10’2” TLFJ12xx

1˝7/8˝

9/16˝

˝2

3/8

1 ˝

F

K 29 Ga. Univ. Endwall 10’2” TLUE11xx

F

˝4

K 29 Ga. Notched Endwall EL42” TLNEEL32xx

F

˝1

˝6

Notched to fit panel profileF

J 29 Ga. Post Trim 10’2” TLPT10xxxx

3 1/2˝5 1/2˝

6˝7 1/4˝

˝/2

1 1

7 1/2˝7 3/4˝9 3/4˝ 11˝

P

˝8/1 4

1/2˝

4 1/8˝

F

1/2˝

C 29 Ga. AG4 Gable Trim 10’2” TLFS17xx

L 29 Ga. 11.25” Fascia & Soffit 10’2” TLFS17xx

4 3/4˝

˝1/

25

11 1/4˝

1˝˝8/5

4 3/4˝

˝2

M 29 Ga. Inside Corner 10’2” TLIC13xx

F

˝/87

4 1/2˝

2˝/14

F

O 29 Ga. Track Cover Cannonball FM 10’2” TLCT15xx

F1 3/4˝

1 3

/4˝

˝8

/3

1

58/˝

N 29 Ga. Overhead Door 10’2” 12’6” TLODT14xx

F

1 1/2˝

˝8

/7

˝9

P

LG-03

Post Frame Trim

Page 6: post frame light gauge application guide

All information is © copyright Everlast Roofing, Inc. 2010

Application Guidelines

Safety:

Always work safely when installing metal products. Use extreme caution on a roof at all times, and wear gloves and safety glasses to avoid injury. Hearing protection should be used when power-cutting metal panels. Do not walk on panels until all fasteners are installed. Metal panels are slippery when wet, dusty, frosty or oily. Do not attempt to walk on a metal roof under these conditions. Always use OSHA recommended safety harness or equipment when working on a roof. Wear soft-soled shoes to improve traction and to minimize damage to the paint finish. Always be aware of your position on the roof relative to any roof openings, roof edges, co-workers, and penetrations. Installing metal panels on a windy day can be dangerous and should be avoided. Consult OSHA guidelines for more comprehensive safety requirements.

Minimum Slope:

Everlast Roofing light gauge products are designed to be installed on pitches of no less than 3:12. Please contact an Everlast sales representative for product recommendations on lower sloped roofs.

ALLOWABLE UNIFORM LIVE LOADS IN POUNDS PER SQUARE FOOT

Live Load based on L/180 deflection Wind Load (Stress)

Span (Feet) 2ʹ0ʺ 2ʹ6ʺ 3ʹ0ʺ 3ʹ6ʺ 4ʹ0ʺ 2ʹ0ʺ 2ʹ6ʺ 3ʹ0ʺ 3ʹ6ʺ 4ʹ0ʺ

29 Gauge (.015) 156 79 46 - - 207 105 61 - -

1. Maximum allowable loads are based upon a continuous three span sheet application.2. Calculated in accordace with the 1996 AISI Cold Formed Steel Design Manual.3. Maximum allowable loads for wind have been increased by 33%.4. Allowable deflection loads are limited by a maximum deflection ratio of L/180 of span.5. Everlast Roffing, Inc. reserves the right to change the specifications of its products without notice.

Post Frame Light GuagePost Frame Light Gauge

LG-04

Page 7: post frame light gauge application guide

All information is © copyright Everlast Roofing, Inc. 2010

Handling:

A. Do not lift panels from ends while flat. Lift the panels on edge when moving individual panels or when moving panels onto the roof.

B. Do not unload in a jerking or bouncing fashion. While unloading, the bundle must be handled at lift point, specified by Everlast Roofing, Inc. Panels greater than 25' long should be unloaded using spreader bar to prevent panels from bending.

C. Although the paint coating is tough, dragging panels across the surface of one another will almost certainly damage the finish. Improper handling of metal panels may cause scratches to the paint finish. ELR offers matching touch up paint in a variety of standard colors in the event of any scratches to the paint finish. Please note: touch up paint will not weather as well or at the same rate as the original coating or finish.

Storage:

A. If the material is not to be used immediately, it should be stored in a dry place. Moisture trapped between sheets may cause damage to the paint system. The paint system may become soft or water stains may appear which can detract from the appearance and affect the service life of the material. To avoid problems store the materials in a well-ventilated dry area. Stack the materials in an incline position. DO NOT USE PLASTIC TO COVER MATERIALS. THIS CAN CAUSE SWEATING OR CONDENSATION!

Post Frame Light GuagePost Frame Light Gauge

LG-05

Page 8: post frame light gauge application guide

All information is © copyright Everlast Roofing, Inc. 2010

Installation Recommendations:

- Panels can be installed over open purlins. See load chart for spacing- Panels should be installed against any prevailing wind- Panels should be installed square, plumb and properly aligned to one another- Galvanized and galvalume panels should remain void of any condensation containing copper, lead or uncoated steel materials- In situations where an endlap of a panel is required, be certain to overlap upper panel a minimum of 8” over lower panel and apply sealant and butyl lap tape uniformly between the two panels.

Ventilation/Insulation:

Proper design and installation of vapor barriers and ventilation systems are important to prevent condensation and the resulting problems of moisture damage and loss of insulation efficiency. Condensation occurs when moisture-laden air comes in contact with a surface temperature equal to or below the dew point of the air. This phenomenon creates problems that are not unique to metal buildings; these problems are common to all types of construction. In addition to providing resistance to heat transfer, insulation can also protect against condensation forming on cold surfaces, either inside the building or within the wall/roof/system cavity. The arrangement of the building’s insulation system and vapor retarder is the responsibility of the building designer. These are some basic guides to help control condensation.

A. The insulation should have a vapor retarder face on the “warm” side of the insulation. For most buildings, this means that the vapor retarder is on the inside surface (toward the building’s interior).B. The thickness of the insulation must be designed to maintain temperature of the vapor retarder above the interior dew point, using the worst-case expected outside temperature.C. All perimeter conditions, seams, and penetrations of the vapor retarder must be adequately sealed in order to provide a continuous membrane to resist the passage of water vapor.D. Building ventilation, whether by gravity ridge vent, power-operated fans, or other means, contributes significantly to reduced condensation. The movement of air to the outside of the building reduces the interior level of vapor pressure. On the buildings that have an attic space or are being retrofitted with metal roofing systems, vents should be placed at both the eave and peak of the roof in order to prevent a buildup of moisture (humidity) in the attic space. Contact your local building code official or an engineer on proper ventilation practices for you area.

Cutting:

Everlast recommends the use of tin snips or a "nibbler" type electric tool to field cutting metal panels. Cutting metal panels may create metal shavings.

A. These shavings and/or chips must be removed immediately from the panel surface. Failure to remove such shavings or chips may cause staining and/or rust on the panel.. Any such surface damage will void the warranty.B. For your protection goggles should be worn when cutting metal panels and flashing.

* This same principle applies when driving steel fasteners (see pages LG07 & LG08)

Post Frame Light GuagePost Frame Light Gauge

LG-06

Page 9: post frame light gauge application guide

All information is © copyright Everlast Roofing, Inc. 2010

OVERLAP

Roof Structure

Siphon GrooveWoodscrew

SCREW PATTERN NAIL PATTERN

*Note - minimum of 1" fastener penetration is recommended

COVERAGE

Coverage/Overlap and Screw/Nail Pattern of Everlast II™Coverage/Overlap and Screw/Nail Pattern of Everlast II™

LG-07

Page 10: post frame light gauge application guide

All information is © copyright Everlast Roofing, Inc. 2010

SCREW PATTERN NAIL PATTERN

OVERLAP

Siphon Groove

Coverage/Overlap and Screw/Nail Pattern of Everdrain™

COVERAGE

Roof Structure

Wood Screw

Coverage/Overlap and Screw/Nail Pattern of Everdrain™

LG-08

Page 11: post frame light gauge application guide

All information is © copyright Everlast Roofing, Inc. 2010

Panel

Ridge CapFastener

Ridge Vent

Vapor Barrier

Profile01 Universal Ridge

TLURC1xx

Post Frame Vented RidgePost Frame Universal Ridge

LG-09

Page 12: post frame light gauge application guide

All information is © copyright Everlast Roofing, Inc. 2010

Profile02 Rake & Corner

TLRC2xxxx

Panel

Caulk

Caulk

Fastener

Girt

Post

Fastener

Post Frame Rake & Corner

LG-10

Page 13: post frame light gauge application guide

All information is © copyright Everlast Roofing, Inc. 2010

Profile03 Base Angle

TLBA3xx

SkirtBoard

Panel

Inside Closure

Fastener

Caulk

Post Frame Base Angle

LG-11

Page 14: post frame light gauge application guide

All information is © copyright Everlast Roofing, Inc. 2010

Profile04 Fascia Trim

TLFT4xx

Panel

Caulk

Caulk

Fastener

RoofFastener

Fastener

Outside Closure

Caulk

PanelTop Plate

Post

Roof Truss

Inside Closure

Caulk

Purlin

Post Frame Fascia Trim

LG-12

Page 15: post frame light gauge application guide

All information is © copyright Everlast Roofing, Inc. 2010

Profile05 Gable Trim

TLGT5xx

Panel

Panel

Caulk

Outside Closure

Purlin

End Rafter

Caulk

Post Frame Gable Trim

LG-13

Page 16: post frame light gauge application guide

All information is © copyright Everlast Roofing, Inc. 2010

06 “J” Channel

TLJC6xx

Profile

Girt

FastenerPanel

DoorDoor Jamb

Door Stop

Caulk

'J' Channel

Post Frame “J” Channel

LG-14

Page 17: post frame light gauge application guide

All information is © copyright Everlast Roofing, Inc. 2010

07 Double Angle

TLDA7xx

Profile

Panel

Caulk

Inside Closure

Butyl Tape Caulk

Fastener

Fastener

Panel

Girt

Outside Closure

Post Frame Double Angle

LG-15

Page 18: post frame light gauge application guide

All information is © copyright Everlast Roofing, Inc. 2010

08 Universal Sidewall

TLUS8xx

Profile

Panel

Girt

Sloping Rafter

Purlin

Panel

Fastener

Inside Closure

Fastener

Caulk

Butyl Tape

Post Frame Universal Sidewall

LG-16

Page 19: post frame light gauge application guide

All information is © copyright Everlast Roofing, Inc. 2010

09 Drip Cap

TLDC9xx

Profile

Panel

Window Unit

Inside Closure

Fastener

Caulk

Post Frame Drip Cap

LG-17

Page 20: post frame light gauge application guide

All information is © copyright Everlast Roofing, Inc. 2010

Profile10 Post Trim

TLPT10xxxx

Girt

Fastener

Panel

DoorDoor Jamb

Door Stop

Fastener

Caulk

'J' Channel

Post Frame Post Trim

LG-18

Page 21: post frame light gauge application guide

All information is © copyright Everlast Roofing, Inc. 2010

11 Universal Endwall

TLUE11xx

Profile

Post Frame Universal Endwall

Panel

Fastener

Fastener

OutsideClosure

Purlin

Butyl Tape

Inside Closure

Girt

Butyl Tape

LG-19

Page 22: post frame light gauge application guide

All information is © copyright Everlast Roofing, Inc. 2010

12 “F” & “J” Trim

TLFJ12xx

Profile

Post Frame “F” & “J” Trim

Panel

Fastener

InsideClosure

Wall Structure

Panel

Fastener

Caulk

Soffit

Facia Board

Post Trim

LG-20

Page 23: post frame light gauge application guide

All information is © copyright Everlast Roofing, Inc. 2010

Profile13 Inside Corner

TLIC13xx

Girt

Girt

Post

Caulk

Caulk

Fastener

Fastener

Post Frame Inside Corner

LG-21

Page 24: post frame light gauge application guide

All information is © copyright Everlast Roofing, Inc. 2010

Profile14 Overhead Door

TLODT14xx

Door Stops

Man Door

Panel

Door Header

OverheadDoor

Post Frame Overhead Door

LG-22

Page 25: post frame light gauge application guide

All information is © copyright Everlast Roofing, Inc. 2010

Profile15 Track Cover Cannonball FM

TLCT15xx

Post Frame Track Cover Cannonball FM

Girt

Fastener

Panel

Caulk

LG-23

Page 26: post frame light gauge application guide

All information is © copyright Everlast Roofing, Inc. 2010

Profile60 Drip Edge

TL6.5F60xx

Facia BoardCaulk

Drip Edge

Inside Closure

EL Panel

Fastener

Soffit

Butyl Tape

Post Trim

Post Frame Drip Edge

LG-24

Page 27: post frame light gauge application guide

All information is © copyright Everlast Roofing, Inc. 2010

Profile17 Fascia & Soffit

TLFS17xx

Facia Board

Panel

Fastener

Panel

Girt

SoffitFastener

Fastener

Inside Closure

Butyl Tape

Post Frame Fascia & Soffit

LG-25

Page 28: post frame light gauge application guide

All information is © copyright Everlast Roofing, Inc. 2010

Profile19 Formed Valley

TLFV19xx

Post Frame Formed Valley

Panel

Vapor Barrier

Formed ValleySolid Roof Structure

Valley Closure

LG-26

Page 29: post frame light gauge application guide

All information is © copyright Everlast Roofing, Inc. 2010

Profile32 Notched Endwall EL

TLNEEL32xx

Post Frame Notched Endwall EL

Panel

Purlin

Butyl TapeTop & Bottom

of Closure

Caulk

Inside Closure

Fastener

Notched to fit panel profile

Outside Closure

Girt

LG-27

Page 30: post frame light gauge application guide

Notes

Page 31: post frame light gauge application guide
Page 32: post frame light gauge application guide

All information is © copyright Everlast Roofing, Inc. 2010

10 Enterprise CourtLebanon, PA 17042

Office: 888-339-0059Fax: 717-270-6569

7180 N 050 EHowe, IN 46746

Office: 866-562-3782Fax: 260-562-3738

P.O. Box 278, 81 South High St.Bridgton, ME 04009-0278

Office: 888-339-0059Fax: 207-647-5599