power optimizer - commercial solar systems€¦ · power optimizer p600 / p700 / p800p / p850 pv...

Power Optimizer P600 / P700 / P800p / P850 PV power optimization at the module-level The most cost effective solution for commercial and large field installations Specifically designed to work with SolarEdge inverters Up to 25% more energy Superior efficiency (99.5%) Balance of System cost reducon; 50% less cables, fuses and combiner boxes, over 2x longer string lengths possible Fast installaon with a single bolt Advanced maintenance with module-level monitoring Module-level voltage shutdown for installer and firefighter safety Use with two PV modules connected in series or in parallel POWER OPTIMIZER www.solaredge.com

Upload: others

Post on 03-Jun-2020

3 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Power Optimizer - Commercial Solar Systems€¦ · Power Optimizer P600 / P700 / P800p / P850 PV power optimization at the module-level The most cost effective solution for commercial

Power OptimizerP600 / P700 / P800p / P850

PV power optimization at the module-level The most cost effective solution for commercial and large field installations SpecificallydesignedtoworkwithSolarEdgeinverters Upto25%moreenergy Superiorefficiency(99.5%) BalanceofSystemcostreduction;50%lesscables,fusesandcombinerboxes,

over2xlongerstringlengthspossible Fastinstallationwithasinglebolt Advancedmaintenancewithmodule-levelmonitoring Module-levelvoltageshutdownforinstallerandfirefightersafety UsewithtwoPVmodulesconnectedinseriesorinparallel

POW

ER O

PTIM

IZER

www.solaredge.com

Page 2: Power Optimizer - Commercial Solar Systems€¦ · Power Optimizer P600 / P700 / P800p / P850 PV power optimization at the module-level The most cost effective solution for commercial

Power Optimizer P600 / P700 / P800p / P850

PV SYSTEM DESIGN USING A SOLAREDGE INVERTER(5)(6)

THREE PHASE SE15K AND LARGER

THREE PHASE SE16K AND LARGER

THREE PHASE FOR MV GRID

CompatiblePowerOptimizers P600 P600 P700(3) P800p P850(3) P600 P700(3) P800p P850(3)

MinimumStringLength PowerOptimizers 13 12 13PVModules 26 24 26

MaximumStringLengthPowerOptimizers 30

PVModules 60MaximumPowerperString 11250(7) 13500 12750(8) 15300 WParallelStringsofDifferentLengthsorOrientations Yes

Optimizer model(typical module compatibility)

P600 (for 2 x 60-cell PV modules)

P700 (for 2 x 72-cell PV modules)

P800p(for parallel connection of 2x 96-cell 5’’ PV modules)

P850(for series connection of

2x high power or bi-facial modules)

INPUTRatedInputDCPower(1) 600 730 800 850 WAbsoluteMaximumInputVoltage(Vocatlowesttemperature) 96 125 83 120 Vdc

MPPTOperatingRange 12.5-80 12.5-105 12.5-83 12.5-105 VdcMaximumShortCircuitCurrent(Isc) 10.25 11 14 12.5 AdcMaximumEfficiency 99.5 %WeightedEfficiency 98.6 %OvervoltageCategory IIOUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER)MaximumOutputCurrent 15 18 AdcMaximumOutputVoltage 85 VdcOUTPUT DURING STANDBY (POWER OPTIMIZER DISCONNECTED FROM SOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF)SafetyOutputVoltageperPowerOptimizer 1±0.1 VdcSTANDARD COMPLIANCEEMC FCCPart15ClassB,IEC61000-6-2,IEC61000-6-3Safety IEC62109-1(classIIsafety)RoHS YesFireSafety VDE-AR-E2100-712:2013-05INSTALLATION SPECIFICATIONS CompatibleSolarEdgeInverters Threephaseinverters

SE15K&largerThreephaseinverters

SE16K&largerMaximumAllowedSystemVoltage 1000 Vdc

Dimensions(WxLxH) 128x152x43/ 5x5.97x1.69

128x152x50/5x5.97x1.93

128x158x59/5x6.22x2.32

128x152x59/5x5.97x2.32 mm/in

Weight(includingcables) 834/1.8 933/2.1 1019/2.2 1064/2.3 gr/lbInputConnector(2)(3) MC4 MC4DualInput(6) MC4OutputConnector MC4

OutputWireLength

1.2/3.9(portraitorientation)or

1.8/5.9(landscapeorientation)

1.2/3.9(portraitorientation)or

2.1/6.9(landscapeorientation)

1.2/3.9(portraitorientation)or

1.8/5.9(landscapeorientation)

1.2/3.9(portraitorientation)or

2.1/6.9(landscapeorientation)

m/ft

OperatingTemperatureRange(4) -40-+85/-40-+185 ˚C/˚F

ProtectionRating IP68/NEMA6PRelativeHumidity 0-100 %

(1)RatedSTCpowerofthemodule.Moduleofupto+5%powertoleranceallowed.(2) ForotherconnectortypespleasecontactSolarEdge.(3) Longerinputswirelength(90cm)areavailableforusewithsplitjunctionboxmodules(OrderP700-XXXLXXXorP850-XXXLXXX).(4)Forambienttemperatureabove+70˚C/+158˚Fpowerde-ratingisapplied.RefertoPowerOptimizersTemperatureDe-RatingApplicationNoteformoredetails.

© SolarEdge Technologies, Inc. All rights reserved. SOLAREDGE, the SolarEdge logo, OPTIMIZED BY SOLAREDGE are trademarks or registered trademarks of SolarEdge Technologies, Inc. All other trademarks mentioned herein

are trademarks of their respective owners. Date: 07/2018/V01/ENG ROW. Subject to change without notice.

(5)P600andP700canbemixedinonestring.ItisnotallowedtomixP600/P700/P800p/P850withP300/P370/P500/P404/P405/P505inonestring.(6)InacaseofoddnumberofPVmodulesinonestringitisallowedtoinstalloneP600/P700/P800p/P850poweroptimizerconnectedtoonePVmodule.WhenconnectingasinglemoduletotheP800psealthe

unusedinputconnectorswiththesuppliedpairofseals.(7)ForSE27.6K,SE50K,SE55K,SE82.8K:Itisallowedtoinstallupto13,500Wperstringwhen3stringsareconnectedtotheinverterandwhenthemaximumpowerdifferencebetweenthestringsisupto

2,000W;invertermaxDCpower:37,250W.(8)ForinvertersforMVgrid:Itisallowedtoinstallupto15,000Wperstringwhen3stringsareconnectedtotheinverterandwhenthemaximumpowerdifferencebetweenthestringsisupto2,000W;inverter

maxDCpower:45,000W.