    1/6

    y(

    )

    Displa y your ne tw o rk

    a na lysis a ll in pictu re fo rma t!

    Ready-to-use measurements in a glance

    Structured use for accurate and effective operations

    Very simple connections; easily accessed keys

    An instrument "built for the field"

    (straps, around-the-neck holder)

    Measurements made in compliance with EN 50160

    OBSERVE, DIAGNOSE, MONITOR...

    C.A 8332C.A 8334

    ThreePhase

    Power QualityAnalysers

  • 8/12/2019 Power Quality Analizer (Ca_8332)

    2/6

    Principal parameters measured:

    TRM S A C +D C voltage: single voltage

    up to 480 V ; phase-phase voltage up to 600 V.

    TRM S AC , A C +D C current up to 3000 A

    (according to sensors used).

    Peak voltage and current.

    Frequency from 40 to 70 H z.

    A ctive, reactive and apparent pow er per phase

    and their aggregate.

    A ctive, reactive, consum ed and produced energy.

    H arm onics for voltage, current, or pow er up

    to the 50thorder.

    Principal values computed:

    N eutral current.

    C rest factors for current and voltage.

    K factors for current (transform er application).

    Pow er factor, displacem ent factor and tangent.

    Short-term voltage flicker.

    Voltage and current unbalance.

    Total harm onic distortion.

    Average, m in and m ax values

    of any com puted value.

    Regardless of the screen, the synergy

    between the display and the keyboard

    is very efficient.

    Additional functions:

    G raphic data processing.

    A larm s, transients.

    Recording, dating and characteristics of

    disturbances (sw ells, dips and interruptions, etc.)

    D ata storage.

    Im m ediate screen printout to printer.

    Screen storage.

    O ptical link com m unication.

    Designed for Electrical Energy departments and Maintenance

    services in industrial and administrative buildings, the Qualistar

    C.A 8332 and C.A 8334 give an instantaneous image of the main

    characteristics of the quality of your electrical network.

    These instruments also provide numerous calculated values

    and processing functions in compliance with standards in use

    (EN 50160, IEC 61000-4-15, IEC 61000-4-30, IEC 61000-4-7).

    Display mode

    Horizontal cursor

    Vertical cursorfor selecting phases

    Date and Hour

    Battery status

    Pop-up menu functions;the active function stays yellow.

    P R E S E N TATI O N

  • 8/12/2019 Power Quality Analizer (Ca_8332)

    3/6

    A keyboard divided

    into easily identifiable zones

    Along with its high-performance measurements,the Qualistar is ergonomic and offers a user-friendly

    operating mode.

    Waveform Mode

    F U N C T I O N S

    G lobal THD and phase by phase in U, I,V, VA in % , RM S value and harm onicsphase shift.O nly the C .A 8334 m odel offers theharm onics function in VA and theexpert m ode. This m ode provides ananalysis of harm onics influence onneutral heating or rotating m achines.

    Pow er /Energy Mode

    "Diagnosis" stage:Harmonics Mod e

    Very structured display modes

    for 3 distinct stages

    "Observation" stage:

    In this m ode, three types of representations are possible: graphic, table, vectoral.

    RM S m easurem ents in U and I. PEA K, M IN, M AX, AVG , KF, Pst, C F, phase shift, unbalance m easurem ents

    This m ode displays all of the valuesrelative to the pow er and energy.The Start and Stop keys activateand deactivate the aggregate ofenergies.M easurem ents for:

    W , Var, VAW h, W arh, VAhPF, DPF or cos and tan

    Pop-up menus

    Display modes

    Cursors and validation

    Direct functions

    The keys, w hich are clearly identifiable

    by their shapes, positioning and

    pictogram , m ake m astering the instrum ent's

    functions rapid and easy.

  • 8/12/2019 Power Quality Analizer (Ca_8332)

    4/6

    C onfiguring instrum ent via softw are: setup, recording and alarm s m odes.

    Recorded and alarm data processing.

    G raphic representation of data in W indow sTM

    environm ent.

    D ata analysis in com pliance w ith EN 50160 standard.

    Screen printout and transient transfers in BM P form at.

    3D representation of harm onics.

    D ata to spreadsheet transfer (Excel).

    Input characteristics

    Voltages: phase-phase: 600 V TRM Sphase-neutral: 480 V TRM S

    Currents: according to sensorsM N clam p: 2 A ... 240 AC clam p: 3 A ... 1 200 AA m pFLEX: 10 A ... 3 000 APA C : 10 A ... 1 000 A A C

    10 A ... 1 400 A D CA dapter unit casing for external C T

    S P E C I F I C A T I O N S

    General characteristics

    Power supply: M ains: 110 V and 230 VN iM H (9.6 V ) rechargeable battery

    Autonomy: 10 hoursTemperature for use: 0... 50CStorage temperature: - 40... 70C

    Standards: EN IEC 61010, 600 V cat. III, pollution 2D ouble insulation for inputs and outputs

    Dimensions (L x W x H): 180 x 55 x 240Weight: 1.5 kg w ith battery

    Frequency range: 40 - 70 H zVoltage accuracy: 0.5 %

    Current: 0.5 %Power: 1 %

    Power factor: 0.01Frequency: 0.01 Hz

    THD (total harmonic distortion): 1 % L 2 ptsEnergy: 1 % L

    Sampling frequency: 12.8 kH z / channel at 50 H z

    Functional characteristics

    Functions C.A 8332 C.A 8334

    Display color LCD 320 x 240 color LCD 320 x 240

    Memory 2 M bytes 4 M bytes

    Battery 1800 m Ah 3800 m Ah

    Harmonics Yes Yes + expert m ode

    Recording Yes (lim ited) Yes

    Alarms Yes Yes

    Transients No Yes

    Mains AC+DC AC+DC

    Digital link RS 232 RS 232

    W ith the

    around-the-neck

    holder, m aking

    m easurem ents

    is easy: operating

    the instrum ent and

    reading the displays

    at the sam e tim e.

  • 8/12/2019 Power Quality Analizer (Ca_8332)

    5/6

    A ll desired param eters are savedw ith their visual graphics duringa recording.N ote that a bargraph locatedat the top of the w indow givesthe total recording period,program m able recording periodand storing rate.

    The transient m ode captureschanges of the voltage and currentw ith triggers on thresholds.Representation over 4 periodsof the captured event at 256 counts/ period, also available w ith zoom .

    Tra nsient Mo d e

    "Monitoring" stage:

    Alarms Mode

    The sim plicity of theinstrum ent's set-up isenhanced by the use ofgraphic representations:type of clam p, connection,color of phases, param eters

    to record

    Q ualistar can be connecteddirectly to a printer forim m ediate screen printing.

    If needed, the help keyexplains functions inrelation to the view edscreen in sim ple term s.

    Press this key to m akea copy of the screen.Storing the view ed screenis autom atic w ith dateand tim e recording.U p to 12 screenrecordings (C .A 8334).

    Recording Mod e

    Printing

    Help

    The alarm s are defined duringthe instrum ent's configuration.The alarm m ode displays allthreshold events w hich occurduring the m easurem ent period.

    Direct function keys:

    Configuration

    Screen Shot

    A utom atic tim e and daterecording of the alarm ,the m axim um correspondingvalue, and the duration ofthe event.

  • 8/12/2019 Power Quality Analizer (Ca_8332)

    6/6

    YOUR DISTRIBUTOR

    TEST & MEASU REMEN T DIV ISION

    FRANCE

    190, rue C ham pionnet

    75876 PAR IS C edex 18

    Tel: +33 1 44 85 44 86

    Fax: +33 1 46 27 95 59

    e-m ail: exp ort@ chauvin-arnoux.fr

    w w w .chauvin-arnoux.fr

    UNITED KINGDOM

    W aldeck H ouse - W aldeck R oad

    M AIDEN HEAD SL6 8BR

    Tel: 01628 788 888

    Fax:01628 628 099

    e-m ail: info@ chauvin-arnoux.co .uk

    w w w .chauvin-arnoux.co.uk

    Power Quality Analyser :

    Instrum ent com es com plete (as per grid) w ith:

    - 1 Q ualistarView softw are- 1 D B9F standard optical lead

    - 4 x 3m leads fitted w ith banana plugs

    - 4 crocodile clips

    - 1 m ains lead

    - User's m anual

    VERSIONS (terminals colors)French (red, green, yellow , blue) F R

    International (red, blue, black, w hite) I N

    CURRENT SENSORS IN A SHOULDER BAGNone X X

    Set of 3 C193 clam ps (1000A - dia: 52 m m ) C X

    Set of 3 Am pflex A193 (3000A -dia: 140 m m / length 450 m m ) A 1

    Set of 3 Am pflex A193 (3000A -dia: 250 m m / length 800 m m ) A 2

    Set of 3 M N93 clam ps (240A- dia: 20 m m ) M N

    Set of 3 PAC 93 clam ps (1400A - dia: 42 m m ) P A

    USER'S MANUAL LANGUAGESFrench (by default) F R

    English G B

    G erm an A L

    Italian I T

    Spanish E S

    Portuguese P T

    2P MAINS SUPPLY LEADFrench, G erm an, or Spanish (by default) F

    English G

    Italian I

    Sw iss C

    USA U

    O r:

    P01160501: W ATT C.A 8332-F M N clam p P01160503: W ATT C .A 8332-Int M N clam p

    P01160601: W ATT C.A 8334-F M N clam p P01160603: W ATT C .A 8334-Int M N clam p

    P01160502: W ATT C.A 8332-F Am pflex (450 m m ) P01160504: W ATT C.A 8332-Int Am pflex (450 m m )

    P01160602: W ATT C.A 8334-F Am pflex (450 m m ) P01160604: W ATT C.A 8334-Int Am pflex (450 m m )

    ACCESSORIES:P01120327: SET O F 3 C193-F* CLAM PS P01120321: SET O F 3 C193-Int** C LA M PS

    P01120422: SET O F 3 M N 93-F* C LAM PS P01120423: SET O F 3M N 93-Int** C LAM PS

    P01120535: SET O F 3 AM PFLEX A 193 450 m m -F* P01120523: SET O F 3 AM PFLEX A 193 450 m m -Int**

    P01120536: SET O F 3 AM PFLEX A 193 800 m m -F* P01120524: SET O F 3 AM PFLEX A 193 800 m m -Int**

    P01120076: SET O F 3 PAC 93-F* CLA M PS P01120077: SET O F 3 PAC 93-Int** C LA M PS

    P01101959: 5A CA833X-F* ADAPTER UNIT P01101959A: 5A CA833X-Int** ADAPTER UNIT

    P01298051: SHO U LDER BAG FO R C ABLE N 6 P01298055: SHO ULDER BAG FO R INSTRUM ENT N 21

    TO O R D E R

    906211032-Ed.

    2-VS02/2002-Characteristicssubjecttomodificationsaccordingtotechnologicaldevelopments.

    C A 8 3 3 2

    C A 8 3 3 4

    * F = French version: Users manual in French L1 / red, L2 / green, L3 / yellow, N / blue

    * * Int. = Internat ional version: Users manual in English L1 / red, L2 / blue, L3 / black, N / wh ite