precision microfluidic oscillators for on-chip timing and control

17
Professor: Cheng-Hsien, Liu Student: Hao-Ran, Shih (9933533) Date: 2010/12/28 Philip N. Duncan, Transon V. Nguyen and Elliot E. Hui Department of Biomedical Engineering, University of California, Irvine, CA, USA

Upload: raya-chaney

Post on 30-Dec-2015

45 views

Category:

Documents


0 download

DESCRIPTION

PRECISION MICROFLUIDIC OSCILLATORS FOR ON-CHIP TIMING AND CONTROL. Philip N. Duncan, Transon V. Nguyen and Elliot E. Hui Department of Biomedical Engineering, University of California, Irvine, CA, USA. Professor: Cheng-Hsien, Liu Student: Hao-Ran, Shih (9933533) Date: 2010/12/28. Outline. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: PRECISION MICROFLUIDIC OSCILLATORS FOR ON-CHIP TIMING AND CONTROL

Professor: Cheng-Hsien, LiuStudent: Hao-Ran, Shih (9933533)

Date: 2010/12/28

Philip N. Duncan, Transon V. Nguyen and Elliot E. HuiDepartment of Biomedical Engineering, University of California, Irvine, CA, USA

Page 2: PRECISION MICROFLUIDIC OSCILLATORS FOR ON-CHIP TIMING AND CONTROL

OutlineABSTRACTINTRODUCTIONTHEORYEXPERIMENTALCONCLUSION

Page 3: PRECISION MICROFLUIDIC OSCILLATORS FOR ON-CHIP TIMING AND CONTROL

ABSTRACT1.A precision pneumatic oscillator which provides timing signals for integrated microfluidic digital logic circuits2.The design is based on the classical ring oscillator circuit and requires only a vacuum supply for power3.Integrate pneumatic and fluidic circuits to

create an autonomously driven peristaltic pump

Page 4: PRECISION MICROFLUIDIC OSCILLATORS FOR ON-CHIP TIMING AND CONTROL

INTRODUCTION1.Microfluidic Large-Scale-Integration has been

a highly successful technology for the automation of multiplexed chemical reactions

2.A control system built solely out of microfluidic components would be attractive because it could be manufactured in parallel with fluid-handling elements on a single chip

3.Lab-on-a-chip devices require timing to control fluid-handling elements such as peristaltic pumps must be driven by carefully coordinated waveforms

Page 5: PRECISION MICROFLUIDIC OSCILLATORS FOR ON-CHIP TIMING AND CONTROL

Device fabrication

THEORY

Page 6: PRECISION MICROFLUIDIC OSCILLATORS FOR ON-CHIP TIMING AND CONTROL

Mathies technology

IN

OUT

Vacuum Source Ground

Page 7: PRECISION MICROFLUIDIC OSCILLATORS FOR ON-CHIP TIMING AND CONTROL

Ring Oscillator Circuit1.The system is inherently unstable and will

thus oscillate indefinitely. (odd number )2.The frequency of oscillation should vary

linearly with 1/(pneumatic resistance ), allowing tuning of the oscillator.

Page 8: PRECISION MICROFLUIDIC OSCILLATORS FOR ON-CHIP TIMING AND CONTROL

EXPERIMENTAL mask layout for a 3-

inverter ring oscillator

Page 9: PRECISION MICROFLUIDIC OSCILLATORS FOR ON-CHIP TIMING AND CONTROL
Page 10: PRECISION MICROFLUIDIC OSCILLATORS FOR ON-CHIP TIMING AND CONTROL

photodiode detector Movement of the elastomeric membrane in

the valve causes a deflection of the laser beam resulting in a change in measured intensity

Page 11: PRECISION MICROFLUIDIC OSCILLATORS FOR ON-CHIP TIMING AND CONTROL

Frequency Design other resistances in the circuit begin to

dominate, such as the resistance of the lines connecting the 3 inverter stages

saturate

Page 12: PRECISION MICROFLUIDIC OSCILLATORS FOR ON-CHIP TIMING AND CONTROL

changing the mask layout to minimize interconnect distances

Page 13: PRECISION MICROFLUIDIC OSCILLATORS FOR ON-CHIP TIMING AND CONTROL

The worst long-term drift was measured to be approximately 4% per hour.

The timing of a 1-hour chemicalreaction should be accurate to within 3 minutes.

Page 14: PRECISION MICROFLUIDIC OSCILLATORS FOR ON-CHIP TIMING AND CONTROL

The use of an oscillating pneumatic circuit to drive the operation of a peristaltic pump

Next page

Page 15: PRECISION MICROFLUIDIC OSCILLATORS FOR ON-CHIP TIMING AND CONTROL
Page 16: PRECISION MICROFLUIDIC OSCILLATORS FOR ON-CHIP TIMING AND CONTROL

CONCLUSION1.The tuning of oscillator frequency through

the variation of resistor sizes in the circuit, achieving a range of 1 Hz to 100 Hz.

2.No characterized oscillator stability,but establishing in devices that the short-term fluctuation and longterm drift is suitable for lab-on-a-chip applications.

3.The only external input required is a vacuum source, it may be possible to use such devices in limited-resource settings.

Page 17: PRECISION MICROFLUIDIC OSCILLATORS FOR ON-CHIP TIMING AND CONTROL