prefabricated cabin wet unitsejintec.co.kr/server/data/file/catalogs_company/... · 2021. 1....
TRANSCRIPT
-
PREFABRICATED CABINWET UNIT
Revision Date : Jan.2021
SEJIN Technical Industries Co., Ltd.
15, Eogokgongdan 5-gil, Yangsan-si, Gyeongnam(50591), Korea.Tel. +82-55-782-1180 Fax. +82-55-782-1001E-Mail : [email protected]
Head office / Factory / Warehouse
-
Challenge towards the TopCraftsmen to the world’s finest ships and Offshore Modules.Leading company in the maritime field in Korea since 1988.
CONTENTS
P. 05P. 07
PREFABRICATEDCABIN
NORSOK STANDARDCABIN LAYOUT
P. 19
REFERENCE
REFERENCE
P. 25
QHSE
QHSE
P. 27
CONTACT US
CONTACT US
0201SEJIN Head office in Yangsan, Korea
P. 11P. 13
PREFABRICATEDWET UNIT
BATHTUB UNITSHOWER UNIT
P. 15
PREFABRICATIONPROCESS
PREFABRICATIONPROCESS
P. 17
INSTALLATION
INSTALLATION
-
Bathtub Type
0403
UPOLSTERY
WINDOW CURTAIN
FURNITURE
BED CURTAIN
DOOR BLADE
WALL PANEL
CEILING PANEL
FLOOR FINISH
PREFABRICATED CABIN SEJIN produces top quality Prefabricated Cabins which satisfy the NORSOK Standard.It also has excellent sound absorption and protection stability, so it has a large share in domestic and overseas markets. SEJIN manufactures and produces the highest quality Prefabricated Cabins for our customers.
Complying to the NORSOK Standard
Prefabricated Cabin Wet Unit
EDDA ACCOMMODATION VESSELCABIN
IMO CERTIFIEDMATERIALS FIRE RETARDANT
SOUNDREDUCTION
THERMAL
-
To satisfy NORSOK StandardsSEJIN is producing top quality Prefabricated Cabins that satisfy NORSOK Standards.SEJIN manufactures and produces the best quality Cabins and for delivery to customers.
PREFABRICATED WET UNIT
FURNITURE, EQUIPMENTAND ACCESSORIES
C-002
(ARCHITECTURALCOMPONENTSAND EQUIPMENT)
C-002
(ARCHITECTURAL COMPONENTS AND EQUIPMENT)
ARTICLENORSOK STANDARDITEM
17.2
17.3
17.11
20.1
FLOOR
GENERAL REQUIREMENTS
WALL
FLOOR ELECTRICAL HEAT
WORKINGENVIRONMENTREQUIREMENTS
S-002
(WORKING ENVIRONMENT)5.5.3
OTHER ACOUSTIC REQUIREMENTS
EASY TO CLEAN, WITHOUT COMPLICATED JUNCTIONS AND RECESSES OR NICHES.DUST TRAPS ARE AVOIDED.
SEAMLESS AND GENTLE RADIUS WALL PANEL.
SHALL BE POSSIBLE TO REPLACE DAMAGED CABLES EASILY DURING THE OPERATIONAL PHASE WITHOUT DISMANTLING THE BATHROOM UNIT.
WALL PANEL (CABIN TO CABIN)R’w 45dB = Rw 45dB + 5dB [C002] + 3dB [S002]
DOOR (CABIN TO CORRIDOR)R’w 40dB = Rw 40dB + 5dB [C002] + 3dB [S002]West Mira Project / 1-man Unit cabin
T HERMAL- Delivers outstanding insulation performance.
N OISE- Provides quality product that meets the noise standards.
F IRE- Excellent product that passed through FIRE TEST.
Provides stability that satisfies NORSOK Standard
NORSOK
TOTAL MOHO NORD PROJECT2 MEN CABIN
05 06
NORSOK STANDARDPREFABRICATED CABIN NORSOK STANDARD CABIN LAYOUT
FABRICATED AS ONE WATERTIGHT JOINT LESS UNIT OF STAINLESS STEEL, ALUMINIUM OR OTHER NON-CORRO-SIVE MATERIAL.
OWNER TYPE CLASS SHIPYARD
WEIDONG FERRY(KOREA) RO-PAX KR
HYUNDAI MIPO DOCKYARD CO., LTD. (KOREA) 134 SET
EDDA(KOREA) ACCOMM VESSEL
DNV.GLCOMF V(1)
HYUNDAI HEAVY IND. CO., LTD.(KOREA) 406 SET
MAERSK DRILLING(DENMARK) JACK-UP RIG
DNV.GL(NORSOK)
DAEWOO SHIPBUILDING & MARINEENGINEERING CO., LTD. (KOREA) 180 SET
TOTAL(FRANCE) FPU BV
HYUNDAI SAMHO HEAVY IND. CO., LTD.(KOREA) 225 SET
SEADRILL(NORWAY) SEMI-RIG
DNV.GL(NORSOK)
HYUNDAI SAMHO HEAVY IND. CO., LTD.(KOREA) 150 SET
FRED OLSEN(NORWAY) SEMI-RIG
DNV.GL(NORSOK)
HYUNDAI HEAVY IND. CO., LTD.(KOREA) 140 SET
SLP (UK)NEXEN(UK)FIXED
PLATFORM DNV.GL 70 SET
Quantity of SET
Updated on JAN.2021 REFERENCE
TOTAL 1,305 SET
-
07 08
CABIN LAYOUT
TYPICAL DRAWINGNORSOK CABIN TYPE
CREW CABIN TYPE
PASSENGER CABIN TYPE
4500
4250
2100
4040
1990
4185
2250
4180
46503535
4160
4175
4945
1 MAN
CREW CLASS
RO-PAX CRUISE
OFFICE CLASS CAPTAIN CLASS
TYPICAL CONSTRUCTION
TYPICAL SECTION BETWEENCABIN AND WET UNIT
TYPICAL SECTION BETWEENCABIN AND LOBBY
CEILING PANEL
CABIN
CEILING PANEL
DETAIL "A"
10
CLE
AR O
PENI
NG H
EIG
HT
: 205
0
10
25
2 MAN
LAYOUT PLAN
25 30 25
25
(FR
OM
FLO
OR
)10
00
25
100
75
CORRIDOR SIDETOILET SIDE
SEALING
SECTION "D - D"
DETAIL "B"
DETAIL "A"
DETAIL "C"
TOILET SIDE
CABIN SIDE
PREFABRICATED CABIN NORSOK STANDARD CABIN LAYOUT
-
Shower Unit
Bathtub Unit
1009
IMO CERTIFIEDMATERIALS
FIRE RETARDANT
PREFABRICATED WET UNITThink of the Wet Unit with fine details and beautiful designs.
WEIDONG FERRY RO-PAXWET UNIT
HYGIENICSOUNDREDUCTION
-
1211
BATHTUB UNIT
ACCESSORIESISOMETRIC PERSPECTIVE
ENGINEERING DRAWINGPERSPECTIVE
PREFABRICATED WET UNIT BATHUB UNIT SHOWER UNIT
FAUCETSHOWER PIPE
SINGLE HOOK TOILET BRUSH HOLDER
ROLL HOLDER
SPARE ROLL HOLDER
TOOTHBRUSH TUMBLER
SOAP DISH
GRAB BAR
BATH TOWEL HOLDER
TYPE-A (1500X1900) TYPE-B (1600X2000)
DOUBLE TOWEL HOLDER
SHOWER MIXER
LOTION DISPENSER
1600
2000
1500
1900
-
1413
SHOWER UNIT
ACCESSORIES
ISOMETRIC PERSPECTIVE
ENGINEERING DRAWINGPERSPECTIVE
PREFABRICATED WET UNIT BATHUB UNIT SHOWER UNIT
TYPE-A (1350X1650)
TYPE-D (1210X2030) TYPE-E (1038X2060)
TYPE-B (1200X1800) TYPE-C (1600X1700)
GRAB BAR ROLL HOLDER TOOTHBRUSH TUMBLER
SHOWER MIXER SHOWER HEAD FAUCET SOAP DISH BATH TOWEL HOLDER
TOILET BRUSH HOLDER
1650
1350
1800
1200
1700
1600
1210
2030
1038
2060
-
WORK PROCEDURE
Locatethe wet unit
A
Assemble the wall,ceiling panel, and cabin door
B
Installthe furniture
C
Install the electricalequipment and cables
D
Inspectionand test
E
Packing
F
Move to storage
G
A B C D E F G
WORK PROCEDURE OF PREFABRICATION
WORK FLOW
Storage and LoadingSTORAGE
LOADING
Suggested storage method for SEJIN Prefabircated Cabins- To be stored indoors, i.e. warehouse- To be stored in a dry and clean environment- To be stored above floor level at least 150 mm- To be stored by area or cabin number for ease of access or by delivery schedule.
Using proper lifting device, i.e. folk-lift truck, to transfer SEJIN prefabricated cabin. A proper fork-lift truck with long flat forks.The forks should be long enough to extend at least 50mm over the other end of the cabin once the cabin is lifted onto the forklift truck. Fasten the prefabricated cabin onto the truck with belt or robe to stabilize the unit. Do not climb on to the top of the unit during fastening.
15 16
PREFABRICATION PROCESSPREFABRICATION PROCESS PREFABRICATION PROCESS
-
Storage01
Loading02
Clean the site before Assemble
Clean the site where assemble will occur. Make sure enough space andheight are reserved for free movement. Remove all unnecessary objectsfrom the site before cabin installation.The following works are be finished before installation:(Insulation, Main cable installation, Duct, Plumbing, and Window opening)Mark the cabin position exactly.
03
Moving Cabin on to Right Position05
Fixing on to Deck06
Connection of the Technical System07
Use a transportation device to move cabin to desired location.
During transportation, special care should be taken to supportthe cabin and prevent collision with other objects.Make sure that the cabin is positioned correctly and check with windows.
Make window opening and window box can be installed.
The piping and the e lect ical connection sha l l be made in the service
Finish work & Inspection of Cabin08P lace carpet or viny l on the floor. (include skirt)Furniture p lacement, door adjustment and c leaning of the cab in. Inspect each cabin with the customer according to the FAT procedure
Lifting04Remove the S.Q tube pallet before lifting.Clear the lifting site to ensure safe lifting operation.The prefabricated cabin shall be lifted by means of special lifting device maintaining balance throughout.The lifting shall be carried out with caution and safety considerations.
Suggested storage methods for SEJIN Prefabricated Cabins
- To be stored indoors, i.e. warehouse- To be stored in a dry and deen environment- To be stored aboce floor level at least 150mm- To be stored by area or cabin number for ease of access or by delivery schedule.
Using proper lifting device, i.e. folk-lift truck, to transfer SEJIN prefabricated cabin.A proper fork-lift truck with long flat forks.The forks should be long enough tp extend at least 50mm overthe other end of the cabin once the cabin is lifted onto the forklift truck.Fasten the prefabricated cabin on to the truck with belt or robe to stabilize the unit. Do not climb on to the top of the unit during fastening.
Lay temporary support to start work.The position of cabin can be adjusted using steel adjustment device.Tack welding to steel deck.Fill in fire sealant between deck and cabin base frame to satisfyB-Class construction standards.
17 18
INSTALLATIONINSTALLATION INSTALLATION
-
REFERENCE Reference
REFERENCE
2019
EDDAACCOMMODATION VESSEL
RULE ®ULATIONSHIP YARD
DELIVERY
SHIP TYPE
SHIP OWNER EDDA ACCOMMODATION
DNV.GL COMFORT CLASS V(1)HHI
MAY-2016
ACCOMMODATION VESSEL
CLASS DNV.GL
RULE
MAERSK JACK-UP RIG Standard
RULE ®ULATIONSHIP YARD
DELIVERY
SHIP TYPE
SHIP OWNER MAERSK
NORSOK STANDARD
DSME
JUN-2016
JACK-UP RIG
CLASS DNV.GL
-
REFERENCE Reference
MOHO NORD
RULE ®ULATIONSHIP YARD
DELIVERY
SHIP TYPE
SHIP OWNER TOTAL
SOLAS STANDARDS
HSHI
AUG-2015
FPU
CLASS BV
RULE
WEST MIRA Standard
RULE ®ULATIONSHIP YARD
DELIVERY
SHIP TYPE
SHIP OWNER SEA DRILL
NORSOK
HSHI
APL-2015
SEMI-RIG
CLASS DNV.GL
REFERENCE
2221
-
2423
REFERENCE Reference
REFERENCE
RULE
GOLDEN EAGLE
RULE ®ULATIONSHIP YARD
DELIVERY
SHIP TYPE
SHIP OWNER NEXEN
UKOOA
SLP (UK)
FEB-2013
FIXED PLATFOM
CLASS DNV.GL
RULE
BOLLSTA DOLPHIN
RULE ®ULATIONSHIP YARD
DELIVERY
SHIP TYPE
SHIP OWNER FRED OLSEN
NORSOK
HHI
MAR-2015
SEMI-RIG
CLASS DNV.GL
Standard
-
OHSAS 45001 : 20182625
ISO 14001 : 2015
ISO 9001 : 2015
-
Supporting everywhere in the world
2827
Ideal Locations for Global MarineBusiness Operation
Republic of Korea
Malaysia
China
IndiaSingapore
Indonesia
Greece
Nigeria
Denmark
France
UKAmerica