1 | Page PRELIMINARY REPORT DATE: 27 TH FEB 2015 Customer Name: ERB West Platform, Petronas Carigali Sdn Bhd (SBO) Status of Call: Contractor Instruction From: En. Agku Suffian B Pg A. Razak NATURE OF WORK Problem Reported: Please refer to details below. System Down: Yes / No Inspection Type: Routine Vibration Survey Call Reported by: Muhammad Harizuan/Mohd Fazli Jaafar/Muhammad Nizamuddin Time: Day Location of Inspection: All Area SERVICE DETAILS Service Rendered: Routine vibration survey on Rotating Machineries. Background: February ’15 routine visit. DIAGRAM Analyst’s Summary Report: Review has been completed on below list of machine: 1.0 Event Logs: 1. REINJECTION COMPRESSOR i. K-6260 :- Under commissioning ii. K-6310 :- Normal iii. K-6360 :- Normal 2. COOLER FAN (EWGA) i. E-6270 :- Normal ii. E-6290 :- Highest vibration at Fan Gearbox NDE Vertical axis. * Full diagnosis report will be provided. iii. E-6320 :- Normal iv. E-6340 :- Normal v. E-6370 :- Normal vi. E-6390 :- Normal 3. EWAC GAS COMPRESSOR i. K-2410 :- Normal 4. COOLER FAN (EWDPA) i. E-2420 Unit A :-Highest vibration at Motor NDE Horizontal axis is increased from previously 7.00mm/s to 12.83mm/s. This motor is running in Zone D within this zone is normally considered to be of sufficient severity to cause damage to the machine. * Full diagnosis report will be provided. ii. E-2420 Unit B :- Normal iii. E-2450 Unit A :- Normal iv. E-2450 Unit B :- Normal AFCM

Upload: fazzlie

Post on 16-Sep-2015

5 views

Category:

Documents


0 download

DESCRIPTION

Preliminary Report

TRANSCRIPT

  • 1 | P a g e

    PRELIMINARY REPORT

    DATE: 27TH FEB 2015

    Customer Name: ERB West Platform, Petronas Carigali Sdn Bhd (SBO)

    Status of Call: Contractor Instruction From: En. Agku Suffian B Pg A. Razak

    NATURE OF WORK

    Problem Reported: Please refer to details below.

    System Down: Yes / No Inspection Type: Routine Vibration Survey

    Call Reported by: Muhammad Harizuan/Mohd Fazli Jaafar/Muhammad Nizamuddin Time: Day

    Location of Inspection: All Area

    SERVICE DETAILS

    Service Rendered: Routine vibration survey on Rotating Machineries. Background: February 15 routine visit.

    DIAGRAM

    Analysts Summary Report: Review has been completed on below list of machine:

    1.0 Event Logs:

    1. REINJECTION COMPRESSOR

    i. K-6260 :- Under commissioning

    ii. K-6310 :- Normal

    iii. K-6360 :- Normal

    2. COOLER FAN (EWGA)

    i. E-6270 :- Normal

    ii. E-6290 :- Highest vibration at Fan Gearbox NDE Vertical axis. * Full diagnosis report will be provided.

    iii. E-6320 :- Normal

    iv. E-6340 :- Normal

    v. E-6370 :- Normal

    vi. E-6390 :- Normal

    3. EWAC GAS COMPRESSOR

    i. K-2410 :- Normal

    4. COOLER FAN (EWDPA)

    i. E-2420 Unit A :-Highest vibration at Motor NDE Horizontal axis is increased from previously 7.00mm/s to 12.83mm/s. This motor is running

    in Zone D within this zone is normally considered to be of sufficient severity to cause damage to the machine.

    * Full diagnosis report will be provided. ii. E-2420 Unit B :- Normal

    iii. E-2450 Unit A :- Normal

    iv. E-2450 Unit B :- Normal

    AFCM

  • 2 | P a g e

    5. GAS GENERATOR

    i. G-6590 :- Trending vibration level show gradually increase.

    * Full diagnosis report will be provided.

    ii. G-6600 :- Normal

    iii. G-6610 :- Normal

    6. LUBE OIL COOLER FAN

    i. G-6590C :- Normal

    ii. G-6600C :- Normal

    iii. G-6610C :- Normal

    7. COT PUMP

    i. P-802 :- Normal

    ii. P-803 :- Standby

    iii. P-804 :- Normal

    iv. P-805 :- Normal

    8. INSTRUMENT AIR COMPRESSOR

    i. K-5455 :- Normal

    ii. K-5430 :- Normal

    iii. K-6645 :- Normal

    9. GLYCOL PUMP

    i. P-6205 :- Unable to measure due to blasting activity

    ii. P-6215 :- Unable to measure due to blasting activity

    iii. P-6110 :- Unable to measure due to blasting activity

    iv. P-6120 :- Unable to measure due to blasting activity

    10. DIESEL FIRE WATER PUMP

    i. P-6530 :- Standby

    11. STANBY DIESEL GENERATOR

    i. G-6720 :- Standby

    2.0 Preliminary Recommendations:

    1. E-6290

    - Refer to diagnosis report.

    2. E-2420 Unit A

    - Refer to diagnosis report.

    3. G-6590

    - Refer to diagnosis report.

    3.0 Summary:

    3.1 CBM has completed routine survey on ERB West Platform. 3.2 Based on the preliminary results, only 3 machines were found with significant vibration level which required further action. 3.3 The full report will be released within 7 working days after visit completion.

  • 3 | P a g e

    Status after Service: (Please circle) Complete/ Incomplete/Under Observation/ Working solution provided

    Events for Tomorrow: None

    Start of Service: 9th Feb 2015

    End of Service: 23th Feb 2015

    PERSONNEL INVOLVED:

    1) Muhammad Harizuan Bin Harudin - CBM Tech 2) Mohd Fazli Jaafar - CBM Tech 3) Muhammad Nizamuddin Bin Mazlan - CBM Tech