presentation aicvf 2013 - freeaicvflr.free.fr/rt/crt_juin_2013_swegon.pdf · • presentation aicvf...
TRANSCRIPT
• PRESENTATION AICVF 2013
2
Arvika, Suède
Poutre froide
Module
induction
Kvänum, Suède
cta
Tomelilla, Suède
Diffusion
Acoustique et
Régulation
Cantarana di Cona, Italie
Armoire de
climatisation
PAC
2013-07-05 3
LA DIFFUSION
2013-07-05 4
GROUPE FROID - PAC - ARMOIRE DE CLIMATISATION
2013-07-05 5
POUTRE CLIMATIQUE
2013-07-05 6
CTA PLUG AND PLAY
2013-07-05 7
Les batteries à eau glycolée
Air neuf Air neuf
Le récupérateur à plaques
2013-07-05 9
Le récupérateur rotatif
2013-07-05 10
Secteur de purge
2013-07-05 11
Sans secteur de purge Avec secteur de purge
Secteur de purge en standard GOLD RX
2013-07-05 12
2013-07-05 13
2013-07-05 14
GOLD, version E
Some products are new, some are revolutionary
2013-07-05 15
What’s new?
• Upgraded design
• Ground breaking control pad
• Easy to use control platform
• New smart features
• Communication for the 21st century
• New sizes for optimized energy efficiency
• New and changed “built-in functions”
2013-07-05 16
GOLD, version E
Unique design
• More professional look
• New connection hood
2013-07-05 17
GOLD, version E
Ground breaking control pad
• The new IQnavigator control interface
• Easy to use touch-screen
• WiFi connection as an option
2013-07-05 18
GOLD, version E
Easy to use control pad platform
• Flow chart of the unit in start view
• Simple to manoeuver, just tap and scroll
• Intuitive menus
• Visual system overviews
• Quickly understandable logging diagrams
2013-07-05 19
GOLD version E
New smart features
• Set-up wizard for quick and easy
commissioning
• Step-by-step filter calibration guide
• Easy to overview alarm log
• Help texts
2013-07-05 20
GOLD, version E
2013-07-05 21
GOLD, version E
2013-07-05 22
GOLD, version E
2013-07-05 23
GOLD, version E
Easy to use control platforms
• The new IQlogic control platform
2013-07-05 24
GOLD, version E
Communication for the 21st century
• WiFi connection as standard
• Dual Ethernet connections for maximum security
One for internal communication
One for external communication
• Same platform for IQnavigator control pad and web browser
• Quick and easy to get familiar with the controls
• Why don’t access via your smartphone?
2013-07-05 25
GOLD, version E
Antenna for communication via WiFi
Double Ethernet ports
USB port for future functionality
More secure program updating
Inputs and outputs
2013-07-05 26
GOLD, version D vs E
Three different sizes of IQlogic+
Quick connectors
2013-07-05 27
GOLD, version D vs E
Two types of hand-held terminal
Battery backup
USB port
SD memory card socket
2013-07-05 28
GOLD, version D vs E
New functions
• New switch clock function
• All valves with feedback signal.
• Temperature regulation sequences totally flexible
• New outdoor air temperature compensation
• Pressure sensor for rotary heat exchanger
2013-07-05 29
GOLD, version E
Optimizing fan sizes
• Smaller fans in GOLD 14, 25, 35…
2013-07-05 30
GOLD, version E
Air flow, m3/s
Dis
po
sa
ble
pre
ssu
re. P
a
Air flow, m3/h
SFPv
2,5
2,0 1,5
Exhaust
Air fan
Supply
air fan
GOLD, version E
Flexible operating range
New GOLD sizes
• GOLD sizes 07 and 11
2013-07-05 32
GOLD, version E
Delivery start
Calendar week 36, 2013
ProUnit
Calendar week 24, 2013
2013-07-05 33
GOLD, version E, time schedule
GOLD, version E
New multi-touch and graphical interface
- User friendly, informative and wireless
New control system
- WiFi connection, new web page and latest technology
Upgraded design
- Highlighting a new generation GOLD
New AHU sizes and new fan sizes
- Optimized energy efficiency
New and changed functions
- Flexibility
GOLD PX
Featuring a new generation of plate heat exchangers
New GOLD PX MTE/MPE
New patent pending and unique
plate heat exchanger
- Air tight, eliminates internal leakage
Anti-freezing protection incl. humidity and
temperature regulation
- Optimum heat recovery throughout the year
GOLD PX MTE up to 80% efficiency
- Saves energy
GOLD PX MPE significantly lower pressure drop
- Saves energy
More AHU sizes
- Flexibility
Evaporative cooling coil
Condensor coil
2 compressors
Electronics and control equipment
2013-07-05 38
Complete Chiller
Docked to GOLD RX Top units
Plug and play connection
Fans not located in hot air stream
Cooling recovery
2013-07-05 39
Function
Plug and play connection:
New connection module on GOLD Top
Power supply
Drainage
Communication to GOLD
2013-07-05 40
Easy
2013-07-05 41
Performance
Size Minimum air
flow (m³/s)
Nominal air flow
(m³/s)
Maximum air flow
(m³/s)
Cooling capacity*
(Te=5°C) (kW)
05-1 0,1 0,4
0,65
6
05-2 0,2 0,55 10
08-1 0.22 0.55
1,0
9
08-2 0.30 0.70 15
12-1 0.35 0.85
1,4
14
12-2 0.40 1.05 22
*Preliminary data
All control equipment are included in GOLD
The GOLD terminal handles Cool DX Top
2013-07-05 42
Controls
Optimal position of heat recovery to the coils
2013-07-05 43
Maximum Energy Benefits
Optimal position of heat recovery to the coils
2013-07-05 44
Maximum Energy Benefits
Optimal position of heat recovery to the coils
2013-07-05 45
Maximum Energy Benefits
Condensing
Coil Evaporating
Coil
Exhaust Air Flow
Fresh Air Flow
Extraction
Air Fan
Intake
Air Fan
Rotant
Heat
Recovery
Every compressor works on a dedicated refrigerant circuit
2013-07-05 46
Double Refrigerant Circuit
Refrigerant
Hydrophilic coated evaporating coil
with special fin profile
• Smart built-in damper solution
- Good room air induction even at low flow rates
- Good heating / cooling output throughout the
whole operative range
• Intelligent Wise product.
• Built in controller and a module with occupancy
and temperature sensor integrated in each unit
2013-07-05 47
ADAPT Parasol
• Complete range for offices, conference rooms
and open landscapes
2013-07-05 48
ADAPT Parasol
2013-07-05 49
• Now it is possible and easy to make mixed Super Wise systems with comfort
modules and diffusors
ADAPT Parasol
Super WISE
All Year Comfort GOLD
Control Zone
ADAPT Diffusor
ADAPT Parasol
Master
Sensor Module
x 9
ADAPT Parasol
Master
ADAPT Parasol
Slave
2013-07-05 50
Change the floor layout or building usage without
replacing any product.
It is a more flexible product than a standard
comfort module.
- Master / Slave function in every controller.
- All controller settings can be adjusted and
updated whenever.
- Nozzles can be adjusted to change min &
max air flow and capacity.
- ADC to adjust the air direction
ADAPT Parasol Room
Next Master
ADAPT Parasol Slave (max x9 units)
ADAPT Parasol Master
2013-07-05 51
• Solution for extract air on room level and for centralized extract air
ADAPT Parasol
2013-07-05 52
• All components and accessories factory mounted
ADAPT Parasol
Module controller
Sensor module
with temperature and
presence
detector(Modbus)
ADC
(-40 to +40 angle)
Motor for damper blade
Electrical connections
All factory mounted components are
connected to the wiring terminals Valves and actuators
for heating & cooling
Condensation
Sensor, always
factory-installed
VOC or CO2
sensor
Adjustable nozzle
settings on all four sides
Pressure sensor
(Modbus)
2013-07-05 53
The complete ADAPT Parasol family ADAPT Parasol 600 PF ADAPT Parasol 690 EX
ADAPT Parasol 1290 EX
ADAPT Parasol 600
ADAPT Parasol 1200 ADAPT Parasol 1200 PF
2013-07-05 54
To configure the ADAPT Parasol you will use ProSelect.
The ADAPT Parasol will always have a minimum and maximum airflow
which depends on size and how you configure it.
The occupancy flow is free to chose in between those two values.
2013-07-05 55
New function mode – Variable Air Flow
”Requested air flow all the time”
How does it work? Unoccupancy
(Min)
Occupancy
(Occ)
Boost
(Max)
ADAPT Parasol 1200 & 1290 EX LHLH 1022 W
Air flow at 70 Pa l/s 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
(nozzle pressure) m3/h 0 7 14 22 29 36 43 50 58 65 72 79 86 94 101 108 115 122 130 137 144
2013-07-05 56
Adapt Parasol was launched with the function mode - EcoPulse.
”Highest possible capacity all the time”
How does it work? Unoccupancy
(Min)
Occupancy
(Occ)
Boost
(Max)
ADAPT Parasol 1200 & 1290 EX LHLH 1022 W
Air flow at 70 Pa l/s 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
(nozzle pressure) m3/h 0 7 14 22 29 36 43 50 58 65 72 79 86 94 101 108 115 122 130 137 144
2013-07-05 57
New function mode – 2-Step
How does it work? Unoccupancy
(Min)
Occupancy
(Occ)
ADAPT Parasol 1200 & 1290 EX LHLH 1022 W
Air flow at 70 Pa l/s 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40
(nozzle pressure) m3/h 0 7 14 22 29 36 43 50 58 65 72 79 86 94 101 108 115 122 130 137 144
Integrated ceiling system
2013-07-05 59
Integrated ceiling system
Pacific - Supply Air – Extract Air (SA/EA)
Pacific chilled beam with functions for:
1. Cooling
2. Heating
3. Supply Air
Now we add functions for:
4. Additional Supply Air (SA)
5. Extract Air (EA)
Modular thinking – add what you need!
2013-07-05 60
Five functionalities in one product
Pacific chilled beam with functions for:
1. Cooling
2. Heating
3. Supply Air
Now we add functions for:
4. Additional Supply Air (SA)
5. Extract Air (EA)
Modular thinking – add what you need!
2013-07-05 61
Five functionalities in one product Type room with Pacific SA/EA
A room, base ventilation 40 l/s, 80 l/s when occupancy.
Need for cooling capacity is higher to what we can get with air diffuser system.
Product list:
Base ventilation, water cooling,
additional Supply Air and Extract Air
1x Pacific 2994-2200-SA/EA, 40/80 l/s
SA/EA kit for VAV includes:
- Sound attenuators
- Motorized dampers
- Controller
2013-07-05 62
How does it work?
Capacity Module
1100 / 1600 / 2200 (2700) mm
Connection space
min 94 mm
SA – EA Module
600 mm
Design Module max length is 3000 mm
Minimum length is:
Capacity Module + 94 + 600mm
ex. 1100+94+600=1794mm
ex .1600+94+600=2294mm
ex. 2200+94+600=2894mm
2013-07-05 63
How does it work?
SA/EA module can be located in the
left or right side of the design module
2013-07-05 64
How does it work?
VAV kit
2013-07-05 65
Modular thinking – add what you need!
A complete Supply Air kit with:
• Sound attenuator
• Motorized damper with flow measurement
• Controller with On/Off function for Supply Air
(0 l/s in Off and max 40l/s in On).
A complete Supply Air and Extract Air kit with:
• Sound attenuator
• Motorized damper with flow measurement
• Controller with On/Off function for Supply Air and Extract Air.
(SA module 0 l/s in Off and max 40l/s in On)
(EA module 40 l/s in Off and max 80l/s in On)
Note! This is just schematic flows to illustrate the functionality
40 or
80 l/s
0 or
40 l/s
40 l/s
0 or
40 l/s
40 l/s
A complete Supply Air kit with:
• Sound attenuator
• Motorized damper with flow measurement
• Controller with On/Off function for Supply Air
(0 l/s in Off and max 40l/s in On).
A complete Supply Air and Extract Air kit with:
• Sound attenuator
• Motorized damper with flow measurement
• Controller with On/Off function for Supply Air and Extract Air.
(SA module 0 l/s in Off and max 40l/s in On)
(EA module 40 l/s in Off and max 80l/s in On)